T. Abdelkrim1, E.M. Berkouk2, K. Benamrane1, T. Benslimane3
1Applied Research Unit on Renewable Energies, Industrial zone, B.P. 88, Ghardaïa, Algeria.
2Laboratory of Process Control, Polytechnic National School, Street Hassen Badi, El Harrach, B.P. 182 Algiers, Algeria.
3University of M’sila, BP. 166, street Ichbilia, M’sila, Algeria. [email protected], [email protected]
Abstract—The purpose of this paper is to develop a control and regulation method of input DC voltages of five-level Neutral Point Clamping (NPC) Active Power Filter (APF). This APF is applied for the enhancement of 5,5kV (ph-ph) network power quality by compensation of harmonic currents produced by an induction motor speed variator. In the first part, the authors present a topology of five-level NPC Voltage Source Inverter (VSI), and then, they propose a model of this converter and its PWM control strategy. In the second part, the control strategy of five-level PWM current rectifier is presented. In the third part, to remedy to instability problem of the input DC voltages of the APF, the authors propose feedback control of the five-level PWM rectifier followed by clamping bridge filter. After that, the sliding mode regulator used to control the APF is developed. The application of the proposed feedback control algorithm to the studied cascade offers the possibility of stabilizing the DC voltages of APF. Stable DC bus supply associated with sliding regulator of APF allows getting low-harmonic content network currents with unity power factor. In all over, the instability problem associated with use of multilevel APF is solved. The obtained results are full of promise to use the multilevel APF in high voltage and great power applications.
Index Terms—Active power filter, NPC multilevel inverter, feedback control, PWM rectifier, clamping bridge.
I. INTRODUCTION The increasing use of control systems based on power
electronics in industry involves more and more disturbance problems in the level of the electrical power supply networks [1]. Thus, one remarks a regular increase in currents harmonic distortion and unbalance rates, as well as an important consumption of the reactive power. These harmonic currents yield voltage harmonics and unbalances via impedance of power supply network, which infects the sinusoidal waveform of the electrical power supply voltage. These disturbances of course have bad consequences on electrical equipments, such as strong heating, sudden stopping of the revolving machines or even the total destruction of these equipments.
Several solutions for reducing harmonic current in electrical power supply networks were proposed. Those which satisfy more the industrial constraints are the active
compensators such as shunt active filter, series active filter and combined shunt-series active filters.
In fact, the main role of active filtering is to constantly control the harmonic distortion in an active way by the compensation of the harmonics [2,3]. European standards CEI 61000-3-4 and CEI 61000-3-6 define low, medium and high voltage power supply networks harmonic currents limits [4].
Research on the shunt active filters implied different works concerning harmonics identification methods such as Fourier transform method [5], the method of synchronous reference frame (d-q) [6], and control strategies such as sliding mode regulators, artificial neural networks and fuzzy logic controllers [7-9]. The structures of the filters also knew an evolution, from two-level converters [10,11] to multilevel converters [12-14]. In high power applications, this latter is more adequate, compared to the conventional two-level structure, simply because of the low harmonic distortion rate of source voltage and current, low switching frequency besides no need to use transformer [15-18]. Various topologies are developed such as flying capacitor multilevel converters, diode clamped multilevel converters, NPC multilevel converters, and H bridge multilevel converters.
The unbalance of the different DC voltage sources of the multi-level (NPC) active power filters constitutes the major limitation for the use of these power converters.
The objective of this paper is to stabilise the input DC voltages of five-level NPC APF. For this purpose, a feedback control of five-level PWM rectifier followed by clamping bridge filter is used. This APF is applied for the enhancement of 5,5kV (ph-ph) network power quality by compensation of harmonic currents produced by an induction motor speed variator (Fig. 1).
First part is dedicated to the presentation of model of the three phases five-level NPC VSI with its four carriers triangulo-sinusoidal PWM control strategy. In the second part, the modelling and control of five-level PWM current rectifier is presented. After that the control strategy of the input DC voltages of multilevel NPC APF is developed. The five-level shunt APF is controlled using a sliding mode regulator. At the end, simulation results are presented.
Feedback Control of Five-Level PWM Rectifier: Application to the Stabilization of DC Voltages of Five-Level NPC Active Power Filter
ICEO'11
124
Figure 1. Synoptic diagram of application of shunt APF on power supply fed cascaded thyristor bridge rectifier-two
level VSI-induction motor
II. MODELLING OF FIVE-LEVEL NPC VOLTAGE SOURCE INVERTER
II.1. Modelling of five-level NPC VSI The three phases five-level NPC VSI is constituted by three legs and four DC voltage sources. Every arm has eight bi-directional switches, six in series and two in parallel, and two diodes to get the zero voltage for VKM (Fig. 2). Every switch is composed by a transistor and a diode in anti-parallel [19].
Figure 2. Five-level NPC voltage source inverter
The switch connection function FKS indicates the opened
or closed state of the switch TDKS:
=openTDif0closeTDif1
FKS
KSKS
(1)
For a leg k of the three phases five-level NPC VSI, several complementary laws control are possible. The optimal control law of this inverter is:
−=−=−=
36
24
15
111
KK
KK
KK
FFFFFF
(2)
Half leg connection function bKmF is defined as:
==
6540
3211
KKKb
K
KKKb
K
FFFFFFFF (3)
m =1 : for the lower half leg; m =0 : for the upper half leg
Table 1 gives the electrical quantities characterising each leg.
TABLE 1. EXCITATION TABLE OF A LEG K OF FIVE-LEVEL NPC VSI
1kB 2kB 3kB kMV 1 1 1
21 cc UU + 1 1 0
1cU 1 0 0 0 0 0 1
3cU− 0 0 0
43 cc UU −− The output voltages relatively to the middle point M of
the inverter, using the half leg connection functions, are given as follows:
4
30
20
10
3
3038
2028
1018
2
31
21
11
1
3137
2127
1117
cb
b
b
cb
b
b
b
b
b
cb
b
b
CM
BM
AM
UFFF
UFFFFFF
UcFFF
UFFFFFF
VVV
−
+++
−
+
+++
=
(4)
The simple output voltages are defined as follows:
−−−−−−
=
CM
BM
AM
C
B
A
VVV
VVV
211121112
31 (5)
The input currents of the inverter using the connection functions and load currents are given as follows:
−−−−++=++=++=++=++=
43213210
3302201104
3382281183
3312211112
3372271171
ddddd
bbbd
d
bbbd
d
iiiiiiiiiFiFiFiiFiFiFiiFiFiFiiFiFiFi
(6)
The input filter model is defined as follows:
−−−−=
−−−=
−=
−−=
0321
021
2
21
44
33
22
11
ididididIreddt
dUC
idididIreddt
dUC
idIreddt
dUC
ididIreddt
dUC
c
c
c
c
(7)
II.2. PWM strategy of the five-level NPC VSI
Two-level carrier-based PWM techniques have been extended to multilevel inverters using several triangular carrier signals and one reference signal per phase. For N-level inverter, (N - 1) carriers with the same frequency fc and same peak-to-peak amplitude Ac are disposed such that the bands they occupy are contiguous. The reference, or modulation, wave form has peak-to-peak amplitude Am and frequency fm, and its centred in the middle of the carrier set. The reference is continuously compared with each of the carrier signals (Fig. 3)[20-22]
ICEO'11
125
0.02 0.022 0.024 0.026 0.028 0.03 0.032 0.034 0.036 0.038 0.04-400
-300
-200
-100
0
100
200
300
400
Time(s)
Vre
f Up1
Up2
Up3
Up4
Figure 3. Triangulo-sinusoidal strategy with four bipolar carriers
The different input DC voltages of the inverter are fed by a battery E (Fig. 2). Fig. 4 shows the simple output voltage VA of the five-level NPC VSI. Fig. 5 displays the voltages across input capacitors. It can be noted that these capacitors voltages are unbalanced.
0.02 0.022 0.024 0.026 0.028 0.03 0.032 0.034 0.036 0.038 0.04-500
-400
-300
-200
-100
0
100
200
300
400
500
VA(V
)
Time(s)
Figure 4. Simple output voltage VA
0 0.05 0.1160
170
180
190
200
Uc1
(V)
Time(s)0 0.05 0.1
200
210
220
230
240
Uc2
(V)
Time(s)
0 0.05 0.1160
170
180
190
200
Uc3
(V)
Time(s)0 0.05 0.1
200
210
220
230
240
Uc4
(V)
Time(s) Figure 5. Inverter input capacitors voltages
III. MODELLING AND CONTROL OF FIVE-LEVEL PWM CURRENT RECTIFIER
The advantages of five-level PWM current rectifier
topology (Figure 6) are well known and have been applied in medium voltage and high power applications in the last years. The reversibility of the five-level VSI allows it to work as current rectifier [22].
The basic principle of the five-level hysteresis current control is based on the classical hysteresis control applied to conventional two-level inverters. The five-level hysteresis control algorithm is given by equation (8).
Figure 6. Five-level PWM current rectifier topology
===⇒⋅−<===⇒−<<⋅−
===⇒<<−===⇒⋅<<
===⇒⋅>
.1,1,12.0,1,12
.0,0,1.1,0,02
.0,0,02
321
321
321
321
321
iiik
iiik
iiik
iiik
iiik
BBBdiBBBdidi
BBBdidiBBBdidi
BBBdi
εε
εε
ε
(8)
with: reci0refireci0ik −=ε
kε is the difference between reference current ireci0ref and source current ireci0. di: hysteresis band width IV. CONTROL STRATEGY OF THE INPUT DC VOLTAGES OF
MULTILEVEL NPC APF
In this part, one proposes to remedy to the instability problem of the input DC voltages of five-level APF, by using a clamping bridge filter and feedback control of the output DC voltages of PWM multilevel rectifier [21-24].
IV.1. Modelling and Control of Clamping Bridge
The clamping bridge cell is a simple circuit constituted by a transistor and a resistor in series connected in parallel with a capacitor as shown in Figure 7. The transistors are controlled in order to maintain equality of the different voltages [25-26].
The model of the intermediate filter with clamping bridge
is defined by the following equation:
iridicirirecci
i iiiiIdt
dUC −−++= ++ )1()1(
(9)
with: i
ciiri RU
Ti =
ICEO'11
126
Figure 7. Clamping bridge cell
The transistor is controlled using the following algorithm:
=⇒=−<
=⇒=>
−=
00
1
irii
i
ciiirii
crefcii
iTthendrifR
UTiTthendrif
UU
ε
ε
ε (10)
dr hysteresis band width.
IV.2. Multi DC Bus Link Voltage Controller
In this part, one proposes to enslave the output DC voltage of five-level PWM current rectifier using a PI-based feedback control. The synoptic diagram of five-level PWM current rectifier control is shown in Figure 8 [21-22]. The transfer functions GI(S) and GV(S) are expressed as follows:
SRLR
ViSG
rr
r
si
reciI ⋅+
==)/(1
)/1()( 0 (11)
SCSGV ⋅
=1)( (12)
Figure 8. Synoptic diagram of five-level PWM current
rectifier control
The modelling of this loop is based on the instantaneous power conservation principle with no loss hypothesis. This loop imposes the root mean square (rms) value of network current [27].
Input and output powers are:
+==
−−=
∑
∑
=
=4
1iloadccmrecirciout
3
1i
2reci0r2
reci0rreci0siin
)i(i4U)i(UP
)dt
di2LiRi(VP
(13)
Different quantities Irectm, iload and ic are defined as follows:
−=
⋅⋅+=
⋅⋅+=
loadc
load
iIrectmi2
id42-id3-id22id1i2
irec42-irec3-irec22irec1Irectm (14)
By using of the power conservation principle and
neglecting of joules loss in the resistor Rr, and by considering a sinusoidal supply network current in phase with corresponding voltage Vsi, it can be written:
)(43 0 loadcrectmrecisi iiUiV +⋅⋅= (15)
V. ACTIVE POWER FILTER CONTROL
A medium voltage source of 5.5kV, 50Hz feeds an
induction motor speed variator as illustrated in Fig. 1. This load produces a distorted current of 97 % THD which is above the tolerated THD limit standard. This current with its spectral analysis are presented in Fig. 9.
Torque and speed features of this motor are presented in Fig. 10. At t=10s, rated torque (Tn=7.6kN.m) is applied. It is noticed that the speed turns back to its reference (1500 rpm) after a slight decrease.
Active power filter is controlled using sliding mode regulator [7-9] [28],[29]. From the model of active filter associated to supply network (16) and by considering the error between harmonic current reference and the active filter current as sliding surface (17), and the smooth continuous function as attractive control function (18), one gets the control law (19).
)/( dtdiLiRVV fKffKfKfrefK +=− (16)
with: )/( dtdiLiRVV sKsSKssKK −−= ; K = 1,2 and 3
fKfrefKs iiS −= (17)
))/(.( λ+= ssn SSkU (18)
))/(()/( λ++++= ssKfrefKffKffrefK SSkVdtdiLiRV (19)
The input DC bus of NPC five-level shunt APF is fed by a five-level PWM current rectifier followed by clamping bridge filter. The application of the feedback control on the rectifier allows getting a stable total output DC voltage. Balancing capacitors voltages is guaranteed by the clamping bridge filter.
Figure 11 shows DC bus capacitors voltages before and after application of clamping bridges. Before t=22s, these voltages diverge, but the average voltages remains constant (Ucm). Application of clamping bridges allows getting stable capacitors voltages around there reference of 3kV.
Figure 12 presents first phase of PWM five-level rectifier current irec10 and its reference current irec10ref before and after application of clamping bridge. Part of the power is dissipated in resistances of clamping bridges, which justifies the increase in the amplitude of the current. This current has a 0.006 total harmonic distortion and in phase with the voltage as shown in figure 13.
ICEO'11
127
Reference identified harmonic current ifref1 and output
filter current if1 are almost superimposed as presented in Figure 14. Figure 15.a presents main source voltage Vs1 and current is1 after harmonic current compensation. Spectral analysis is presented in Figure 15.b. It is shown that source current is almost sinusoidal with THD less than 5% and unity power factor. This THD would not have been obtained if the input DC capacitors voltages of APF were unbalanced.
23.96 23.965 23.97 23.975 23.98-600
-400
-200
0
200
400
600
time(s)
is1(
A)
0 10 20 30 40 500
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
harmonic row
harm
onic
am
plitu
de( p
u )
( a ) ( b )
Figure 9. Current drawn by the induction motor speed variator (THD = 0.97)
0 5 10 15 200
500
1000
1500
2000
Time(s)
Spe
ed (r
pm)
0 5 10 15 20-1
0
1
2
3
4
5
6
7x 104
Time(s)
Torq
ue (N
m)
( a ) ( b )
Figure 10. Induction motor mechanical speed and torque
15 16 17 18 19 20 21 22 23 242600
2700
2800
2900
3000
3100
3200
3300
3400
Uc1
(V),U
c2(V
),Uc3
(V),U
c4(V
),Ucm
(V),U
cref
(V)
time(s)
Uc1
Uc3
Ucm
Uc2
Uc4
Ucref
Figure 11. DC bus condensers voltages before and after
application of clamping bridges
21.5 22 22.5 23 23.5-80
-60
-40
-20
0
20
40
60
80
time(s)
irec1
01(A
), ire
c10r
ef(A
)
Figure 12. PWM rectifier current irec10 and its reference
irec10ref
23.96 23.965 23.97 23.975 23.98-150
-100
-50
0
50
100
150
time(s)
Vs1
/40(
V),
irec1
0(A
)
0 10 20 30 40 500
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
harmonic row
harm
onic
am
plitu
de( p
u )
( a ) ( b )
Vs1
irec10
Figure 13. Input voltage and current of PWM rectifier and
spectral analysis of current (THD=0.006)
23.96 23.965 23.97 23.975 23.98 23.985 23.99 23.995 24-600
-400
-200
0
200
400
600
time(s)
if1(A
), ifr
ef1(
A)
Figure 14. Reference harmonic current ifref1 and filter
output current if1
23.96 23.965 23.97 23.975 23.98-400
-300
-200
-100
0
100
200
300
400
time(s)
Vs1
/15(
V),
is1(
A)
0 10 20 30 40 500
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
harmonic row
harm
onic
am
plitu
de( p
u )
( a ) ( b )
Figure 15. Main source voltage Vs1 and current is1 with
its spectral analysis (THD=0.047)
ICEO'11
128
Simulation Parameters:
Main source: Vph-ph=5,5kV, Rs = 0.0001Ω, Ls = 0.001H. Induction motor: Pn=1.2MW, Ωn=1500rpm, Tn=7.6kN.m, VIM(ph-ph) = 2300V, J=46kg.m2, Rsm=0.0406Ω, Rrm=0.0308Ω, Lrm=0.0591H, Lsm=0.0591H, M=0.0581H. Active power filter: Rf = 0.001Ω, Lf = 0.003H, fc=6kHz. Clamping bridge: Ucref=3000V, C=0.05F, R= 5Ω. Five-level PWM rectifier: Ucrefr=3000V, Lr=0.05H, Rr=0.01Ω
VI. CONCLUSION
In this paper, one studies the problem of unbalanced input capacitors DC voltages of five-level NPC shunt active power filter supplied by five-level PWM rectifier.
The modelling of the five-level NPC inverter shows that it is equivalent to four two-level inverters in series. The study of the instability problem of the input DC voltages of this converter shows that its different input voltages are not stables, which implies a bad harmonic current compensation.
To solve this instability problem, one proposes to use a clamping bridge filter to improve input DC voltages balance.
In spite of this solution, the output voltage of five-level rectifier is not constant. To remedy to this problem, one proposes the feedback control of its output voltage. The application of the proposed feedback control algorithm to the rectifier shows a good voltage tracking.
Feedback control algorithm of the rectifier associated with clamping bridge filter makes stable the input DC voltages of five-level APF.
The proposed control algorithm opens the door to different applications of NPC multilevel converters in high power utilities such as, motor drives, doubly fed induction generators, power supply networks interconnection. This work can also be extended to series active power filters.
In active power filter applications, the proposed control makes possible:
- Active power filtering in medium voltage without using transformer.
- Low total harmonic distortion of main source currents.
REFERENCES
[1] V.E Wagner, “Effects of harmonics on equipment”, IEEE Trans.
Power, delivery, vol. 8, pp. 672–680, Apr. 1993. [2] C. Hochgraf, R. Lasseter, D. Divan, T.A Lipo, “Comparison of
multilevel inverters for static var compensation”, in Conf. Rec. IEEE-IAS Annu. Meeting, vol. 3, 1995, pp. 2557–2564.
[3] G. Choe, M. Park, “A new injection method for ac harmonic elimination by active power filter”, In IEEE Transactions on Industry Applications, volume 35, N°1 pages 141-147, february 1988.
[4] S.M. Digă, D. Ruşinaru, A.C. Grigorescu, “Aspects concernant la limitation des effets de la circulation des harmoniques dans les reseaux de distribution”, annals of the University of Craiova, Electrical Engineering, series, No. 30, 2006, pp. 282-287.
[5] J.H. Choi, G.W. Park, S.B. Dewan, “Standby power supply with active power filter ability using digital controller”, in Proc. IEEE APEC'95, 1995, pp783-789.
[6] S. Bhattacharya, D.M. Divan, B.B. Banerjee, “Active filter solutions for utility interface”, in Proc. IEEE ISIE'95 1995, pp. 1-11.
[7] S. Saetieo, R. Devaraj, D. A. Torrey, “The design, implementation of a three-phase active power filter based on sliding mode control”, IEEE Trans. Ind. Applicat., vol. 31, pp993-1000, Sept. Oct. 1995.
[8] Lin. Bor-Ren, Hung. Zong-Liang, Tsay. Shuh-Chuan, Liao. Mu-Shan, “Shunt Active Filter with Sliding Mode Control”, in Proc. IEEE TENCON'OI, Aug. 2001, vol.2, PP884-889.
[9] T. Abdelkrim, E.M. Berkouk, K. Benamrane, T. Benslimane, “Feedback control of three-Level PWM rectifier: Application to the stabilization of DC Voltages of five-level NPC active power filter”, Archives of Control Sciences, Vol.20, No. 3, pp. 253-275, 2010.
[10] Ozdemir. Engin, Kale. Murat, Ozdemir. Sule, “A novel control method for active power filter under non-ideal mains voltage”, in Proc. IEEE CCA, Jun., 2003. Vol. 2, pp.931 936.
[11] N. Mendalek, K. Ai-Haddad, “Modeling and nonlinear control of shunt active power filter in the synchronous reference frame”, in Proc. Harmonics and Quality of Power, 2000, vol. 1, pp30-35.
[12] Rajesh. Gupta, Arindam. Ghosh, Avinash. Joshi, “Control of 3-level shunt active power filter using harmonic selective controller”, in Proc. IEEE Power India Conference, 2006.
[13] V. Aburto, M. Schneider, L. Moran, F. Dixon, “An active power filter implemented with a three-level NPC voltage-source inverter”, in IEEE PESC'97 Record., Jun. 1997, vol. 2, pp1121-1126.
[14] B.R. Lin, H.K. Chiang, C. H. Huang, “Three-phase three-level active power filter with a clamped capacitor topology”, lEE Proc.-Electr. Power Appl., Vol. 153, No 4, July 2006, pp513-522.
[15] N. Akira, T. Isao, A. Hirofumi, “A New Neutral-Point-Clamped PWM Inverter”, IEEE Tran. On Ind. Appl. Vol. IA-17, No .5, Sept/Oct 1981.
[16] J.S. Lai, F.Z. Peng, “Multilevel Converters. A New Breed of Power Converters”, IEEE Tran. On Ind. Appl. Vol. 32, No . 3, May/ June 1996.
[17] V.F. Corasaniti, M.B. Barbieri, P.L. Arnera, M. I. Valla, “Comparison of Active Filters Topologies in Medium Voltage Distribution Power Systems”, in the 21st Century Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy, 2008 IEEE, 20-24 July 2008 Page(s):1 – 8
[18] M. Rastogi, P.W. Hammond, S. R. Simms, “Multi-Level Active Filter for Medium Voltage Applications”, International Conference on Power Electronics and Drives Systems, Volume 2, 28-01 Nov. 2005 Page(s):1508 – 1513
[19] R. W. Menzies, P. Steimer, J. K. Steinke, “Five-level GTO inverters for large induction motor drives”, IEEE Trans. Ind. Applicat., vol. 30,pp. 938–944, July/Aug. 1994.
[20] J. Rodriguez, D. Rodriguez, C. Silva, E. Wiechmann, “A simple Neutral Point Control For Three-Level PWM Rectifiers” EPE 99Lausanne.
[21] F. Bouchafaa, E.M. Berkouk, M.S. Boucherit, “feedback control of dc link voltage of the back–to–back PWM multilevel converter”, Journal of Electrical Engineering, VOL. 58, NO. 6, 2007, 318–325
[22] F. Bouchafaa, E.M. Berkouk, M.S. Boucherit, “Modelling and control of a power electronic cascade for the multi DC bus supply” ,The International Journal for Computation and Mathematics in Electrical and Electronic Engineering Vol. 27 No. 5, 2008.
[23] N. Hor, J. Jung, K. Nam, “A fast dynamic DC link power-balancing scheme for PWM converter-inverter”, IEEE Transactions on Industrial Electronics, Vol. 8 No. 4. 2001.
[24] F.Z. Peng, J.S. Lai, “Dynamic performances and control of a static VAR generator using cascade multilevel inverters”, IEEE Transactions on Industry Applications, Vol. 33. No. 3. 1997.
[25] F. Bouchafaa, E.M. Berkouk, M.S. Boucherit, “Analysis and simulation of a nine-level Voltage Source Inverters. Application to the speed control of the PMSM”, Electromotion Journal. Vol.10 N°3 July-September 2003. PP.246-251.
[26] N. Celanovic,D. Boroyevich, “A Comprehensive Study of Neutral-Point Voltage Balancing Problem in Three-Level Neutral-Point-Clamped Voltage Source PWM Inverters”, IEEE Transactions on Power Electronics, Vol.15, N°.2, pp. 242-250, March 2000.
[27] R. Strzelecki, C. Benyesek, J. Rusinski, “Analysis of DC link capacitor voltage balance in multilevel active power filters”, EPE2001-Gratz.
[28] J. J. Slotine, W. Li, “Applied Nonlinear Control”, Prentice Hall, 1991.
[29] V.I. Utkin, “Sliding mode control design principles and application to electric drives”, IEEE Trans On Elect, Vol 40 feb93, pp23-36.