2

Click here to load reader

144-111-PI-CAL-0004

Embed Size (px)

DESCRIPTION

tyigy

Citation preview

Page 1: 144-111-PI-CAL-0004

file:///tt/file_convert/563dba24550346aa9aa30ed9/document.xls document.xls

Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION

Project P11-b De Ruyter Production Platform Summary Sheet

Doc. No. 144-111-PI-CAL-0004 Rev. R3 System: SK-004

Page 1 of 1

System Description

Line numbers Connecting Equipment

12 TO 220 004 A41 Export Oil Surge Tank 220-TC-01 / N3A

12 TO 220 005 A41 Export Oil Surge Tank 220-TC-01 / N3B

12 TO 220 006 A41 Export Oil Surge Tank 220-TC-01 / N3C

16 TO 220 008 A41 Oil Fiscal Metering 901-XY-01

8 TO 220 012 A41

6; 8 TO 220 028 A41 Export Oil Surge Tank 220-TC-01 / N1

6; 8 TO 200 078 A41 Crude Oil Cooler 200-HP-03 / S2

Status Note

Design Code B 31.3

System designed for blast Partly

CII Calculation no. - blast case SK-004B-R3

CII Calculation no. - design case SK-004A-R3

Process line list Rev. C2

Material specification Rev. C3

Support locations for AFD Yes

Support loads issued AFD Partly

Flexibility approved Yes

Maximum Stresses Sustained Expansion Occasional Blast

92 (67%) 234 (78%) 113 (62%) 136 (46%)

Equipment Nozzle Loads

Tag no. Node no Approved Notes

220-TC-01 / N3A 70 Yes Vendor datasheet Doc.no. KU4 02339

220-TC-01 / N3B 2070 Yes Vendor datasheet Doc.no. KU4 02339

220-TC-01 / N3C 1070 Yes Vendor datasheet Doc.no. KU4 02339

901-XY-01 320 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SPE-0004).

220-TC-01 / N1 4040 Yes Flange assessment

200-HP-03 / S2 4560 Yes For blast no allowables exists, these are checked by combining

the loads with the other nozzles (see "NOZZLE LOADCHECK FOR

200-HP-03")