2
07/19/2022 file:///home/website/convert/temp/convert_html/563dba24550346aa9aa30ee5/document.xls document.xls Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION Project P11-b De Ruyter Production Platform Summary Sheet Doc. No. 144-111-PI-CAL-0016 Rev. R0 System: SK-016 Page 1 System Description Line numbers Connecting Equipment 8; 10 LG 300 003 A41 1st Stage Inlet Scrub 300-VN-01 / N2 Comp. Skid 300-XY-01 / TP-1A Status Note Design Code B 31.3 System designed for blast Yes CII Calculation no. - blast case - CII Calculation no. - design case SK-016A-R0 Process line list Rev. C2 Material specification Rev. C3 Support locations for AFD Yes Support loads issued AFD Yes Support detail drawing approved Yes Flexibility approved Yes Maximum Stresses Sustained Expansion Occasional Blast 44 (32%) 24 (12%) 27 (15%) - Equipment Nozzle Loads Tag no. Node no Approved Notes 300-VN-01 / N2 20 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SP 300-XY-01 / TP-1A 140 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SP

144-111-PI-CAL-0016

Embed Size (px)

DESCRIPTION

fgjdd

Citation preview

Page 1: 144-111-PI-CAL-0016

04/18/2023 file:///tt/file_convert/563dba24550346aa9aa30ee5/document.xls document.xls

Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION

Project P11-b De Ruyter Production Platform Summary Sheet

Doc. No. 144-111-PI-CAL-0016 Rev. R0 System: SK-016

Page 1 of 1

System Description

Line numbers Connecting Equipment

8; 10 LG 300 003 A41 1st Stage Inlet Scrubber 300-VN-01 / N2

Comp. Skid 300-XY-01 / TP-1A

Status Note

Design Code B 31.3

System designed for blast Yes

CII Calculation no. - blast case -

CII Calculation no. - design case SK-016A-R0

Process line list Rev. C2

Material specification Rev. C3

Support locations for AFD Yes

Support loads issued AFD Yes

Support detail drawing approved Yes

Flexibility approved Yes

Maximum Stresses Sustained Expansion Occasional Blast

44 (32%) 24 (12%) 27 (15%) -

Equipment Nozzle Loads

Tag no. Node no Approved Notes

300-VN-01 / N2 20 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SPE-0004).

300-XY-01 / TP-1A 140 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SPE-0004).