3
file:///home/website/convert/temp/convert_html/563dba24550346aa9aa30ee7/document.xls document.xls Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION Project P11-b De Ruyter Production Platform Summary Sheet Doc. No. 144-111-PI-CAL-0018 Rev. R0 System: SK-018 Page 1 System Description Line numbers Connecting Equipment 4 BD 410 015 A41 MP Separator 200-VS-02 / N2 4 LG 200 045 A41 4 LG 200 020 A43 1.5 LG 200 076 A43 Status Note Design Code B 31.3 System designed for blast Yes CII Calculation no. - blast case SK-018B-R0 CII Calculation no. - design case SK-018A-R0 Process line list Rev. C2 Material specification Rev. C3 Support locations for AFD Yes Support loads issued AFD Yes Support detail drawing approved Partly Flexibility approved Yes Maximum Stresses Sustained Expansion Occasional Blast 92 (67%) 72 (35%) 94 (51%) 1) Blast critical only for nodes 10 - 290 and 585 - 1215. Equipment Nozzle Loads Tag no. Node no Approved Notes 200-VS-02 / N2 1050 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SP 194 (80%) 1)

144-111-PI-CAL-0018

Embed Size (px)

DESCRIPTION

fddd

Citation preview

Page 1: 144-111-PI-CAL-0018

file:///tt/file_convert/563dba24550346aa9aa30ee7/document.xls document.xls

Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION

Project P11-b De Ruyter Production Platform Summary Sheet

Doc. No. 144-111-PI-CAL-0018 Rev. R0 System: SK-018

Page 1 of 1

System Description

Line numbers Connecting Equipment

4 BD 410 015 A41 MP Separator 200-VS-02 / N2

4 LG 200 045 A41

4 LG 200 020 A43

1.5 LG 200 076 A43

Status Note

Design Code B 31.3

System designed for blast Yes

CII Calculation no. - blast case SK-018B-R0

CII Calculation no. - design case SK-018A-R0

Process line list Rev. C2

Material specification Rev. C3

Support locations for AFD Yes

Support loads issued AFD Yes

Support detail drawing approved Partly

Flexibility approved Yes

Maximum Stresses Sustained Expansion Occasional Blast

92 (67%) 72 (35%) 94 (51%)

1) Blast critical only for nodes 10 - 290 and 585 - 1215.

Equipment Nozzle Loads

Tag no. Node no Approved Notes

200-VS-02 / N2 1050 Yes Standard Nozzle loadings (Doc.No. 144-000-ME-SPE-0004).

194 (80%) 1)

Page 2: 144-111-PI-CAL-0018

file:///tt/file_convert/563dba24550346aa9aa30ee7/document.xls document.xls