07/19/2022 file:///home/website/convert/temp/convert_html/563dba24550346aa9aa30eec/document.xls document.xls Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION Project P11-b De Ruyter Production Platform Summary Sheet Doc. No. 144-111-PI-CAL-0039 Rev. R1 System: SK-039 Page System Description Line numbers Connecting Equipment Tag no's 4" PW 200 036 A41 LP Separator 200-VS-03 / N4 Produced Water Package 530-TX-01A / TP03 Status Note Design Code B 31.3 System designed for blast Partly From N4 / 200-VS-03 to ESV-043. Suppor CII Calculation no. - blast case SK-039-B-R4 CII Calculation no. - design case SK-039-A-R4 Process line list Rev. C2 Material specification Rev. C3 Support locations for AFD Yes Support loads issued AFD Yes Support detail drawing approved Partly Flexibility approved Yes Maximum Stresses [ MPa] Sustained Expansion Occasional Blast 16,6 (12%) 35,4 (17,1%) 30,6 (16,7%) 86,1 ( Equipment Nozzle Loads Tag no. Node no Approved Notes 200-VS-03 / N4 20 Yes Standard loads, doc 144-000-ME-SPE-0004. 530-TX-01A / TP03 380 Yes Package TP - Standard loads, doc 144-000-ME-SPE 0 0 NOTE: For blast case, the resultant (combined) moment is used.

144-111-PI-CAL-0039

Embed Size (px)

DESCRIPTION

fjf

Citation preview

Page 1: 144-111-PI-CAL-0039

04/18/2023 file:///tt/file_convert/563dba24550346aa9aa30eec/document.xls document.xls

Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION

Project P11-b De Ruyter Production Platform Summary Sheet

Doc. No. 144-111-PI-CAL-0039 Rev. R1 System: SK-039

Page 1 of 1

System Description

Line numbers Connecting Equipment Tag no's

4" PW 200 036 A41 LP Separator 200-VS-03 / N4

Produced Water Package 530-TX-01A / TP03

Status Note

Design Code B 31.3

System designed for blast Partly From N4 / 200-VS-03 to ESV-043. Supports up to N240.

CII Calculation no. - blast case SK-039-B-R4

CII Calculation no. - design case SK-039-A-R4

Process line list Rev. C2

Material specification Rev. C3

Support locations for AFD Yes

Support loads issued AFD Yes

Support detail drawing approved Partly

Flexibility approved Yes

Maximum Stresses [ MPa]Sustained Expansion Occasional Blast

16,6 (12%) 35,4 (17,1%) 30,6 (16,7%) 86,1 (31,9%)

Equipment Nozzle Loads

Tag no. Node no Approved Notes

200-VS-03 / N4 20 Yes Standard loads, doc 144-000-ME-SPE-0004.

530-TX-01A / TP03 380 Yes Package TP - Standard loads, doc 144-000-ME-SPE-0004 are used.

0

0

NOTE: For blast case, the resultant (combined) moment is used.