2
07/19/2022 file:///home/website/convert/temp/convert_html/563dba24550346aa9aa30ef5/document.xls document.xls Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION Project P11-b De Ruyter Production Platform Summary Sheet Doc. No. 144-111-PI-CAL-0049 Rev. R1 System: SK-049 Page System Description Line numbers Connecting Equipment Tag no's 3; 4 BD 410 052 A41 ; 3; CO 200 056 A41 Desalter 200-VS-04 / N4 3" BD 410 227 A41 Produced water package 530-XY-01A / TP25 Status Note Design Code B 31.3 System designed for blast Yes Complete system down to HP header. A sh CII Calculation no. - blast case SK-049B-R1 CII Calculation no. - design case SK-049-R1 Process line list Rev. C2 Material specification Rev. C3 Support locations for AFD Yes Support loads issued AFD Yes Support detail drawing approved Yes Flexibility approved Yes Maximum Stresses [ MPa] Sustained Expansion Occasional Blast 30,5 (22.1%) 142,7 (69%) 35,0 (19,1%) 252,4 Equipment Nozzle Loads Tag no. Node no Approved Notes 0 200-VS-04 / N4 10 Yes (Note 1) Standard loads, doc 144-000-ME-SPE-0004 / and v 530-XY-01A / TP25 480 Yes Package TP - Standard loads, doc 144-000-ME-SPE 0 NOTE: 1. For all design (operating) cases the maximum nozzle loads are within the standard force is used. For blast case the loads have been submitted and approved by vendor twice the allowable).

144-111-PI-CAL-0049

Embed Size (px)

DESCRIPTION

ghkh

Citation preview

Page 1: 144-111-PI-CAL-0049

04/18/2023 file:///tt/file_convert/563dba24550346aa9aa30ef5/document.xls document.xls

Client Petro-Canada Netherlands B.V. PIPE STRESS CALCULATION

Project P11-b De Ruyter Production Platform Summary Sheet

Doc. No. 144-111-PI-CAL-0049 Rev. R1 System: SK-049

Page 1 of 1

System Description

Line numbers Connecting Equipment Tag no's

3; 4 BD 410 052 A41

2; 3; 4 CO 200 056 A41 Desalter 200-VS-04 / N4

3" BD 410 227 A41 Produced water package 530-XY-01A / TP25

Status Note

Design Code B 31.3

System designed for blast Yes Complete system down to HP header. A shape factor of 0.7 is used.

CII Calculation no. - blast case SK-049B-R1

CII Calculation no. - design case SK-049-R1

Process line list Rev. C2

Material specification Rev. C3

Support locations for AFD Yes

Support loads issued AFD Yes

Support detail drawing approved Yes

Flexibility approved Yes

Maximum Stresses [ MPa]Sustained Expansion Occasional Blast

30,5 (22.1%) 142,7 (69%) 35,0 (19,1%) 252,4 (93,6%)

Equipment Nozzle Loads

Tag no. Node no Approved Notes

0

200-VS-04 / N4 10 Yes (Note 1) Standard loads, doc 144-000-ME-SPE-0004 / and vendor approval.

530-XY-01A / TP25 480 Yes Package TP - Standard loads, doc 144-000-ME-SPE-0004 are used.

0

NOTE: 1. For all design (operating) cases the maximum nozzle loads are within the standard loads. Resultant allowable

force is used. For blast case the loads have been submitted and approved by vendor (longitudinal moment is

twice the allowable).