Upload
hoangdan
View
228
Download
3
Embed Size (px)
Citation preview
1508-1T1412
COMMERCIAL AIR CONDITIONERS
Precision AC / Base Station ACP
recision AC
/ Base S
tation AC
D e a l e r i n f o r m a t i o n
Commercial Air Conditioner Business Units
Midea Group
Add: West Region of Midea Commercial Air Conditioner Department, Industry Avenue,
Beijiao, Shunde, Foshan, Guangdong, P. R. China
Postal code: 528311
Tel: +86-757-26338346 Fax: +86-757-22390205
http://global.midea.com.cn
http://www.midea.com
Note: The data in this book may be changed without notice for further improvement
on quality and performance.
Ver.2014.12
Midea CAC (MCAC)As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial solutions. Since 1999 MCAC has contributed to the R&D and innovation of technologically-based commercial solutions. Cooperation with leading global enterprises coupled with independent R&D has enabled MCAC to implement thousands of commercial air-conditioning projects worldwide.
At present, MCAC is one of the globally leading product suppliers, underpinned by a mature marketing, sales, and project design framework.
There are three production bases in Shunde, Chongqing and Hefei.MCAC Shunde: 38 product lines focusing on VRF (DC inverters and digital scroll products), split products, heat pump water heaters, and AHU/FCU.MCAC Chongqing: 14 product lines focusing on water cooled centrifugal/screw/scroll chillers, air cooled screw/scroll chillers, and AHU/FCU.MCAC Hefei: 11 product lines focusing on VRF, chillers, and heat pump water heaters.
Year
2000
2004
20062001 2013
2007
20101999
2011 2014
2014 Launched the All DC Inverter V5X globally2013 Launched the super high efficiency centrifugal chiller with full falling film technology2011 Launched the DC Inverter V4 Plus globally2010 Built the 3rd manufacturing base in Hefei2007 Won the first Midea centrifugal chiller project oversea2006 Launched the first VSD centrifugal chiller 2004 Acquired MGRE entered the chiller industry2001 Partnered with Copeland to develop the digital scroll VRF system2000 Developed the first inverter VRF With Toshiba1999 Entered the CAC field
Midea CAC (MCAC)As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial solutions. Since 1999 MCAC has contributed to the R&D and innovation of technologically-based commercial solutions. Cooperation with leading global enterprises coupled with independent R&D has enabled MCAC to implement thousands of commercial air-conditioning projects worldwide.
At present, MCAC is one of the globally leading product suppliers, underpinned by a mature marketing, sales, and project design framework.
There are three production bases in Shunde, Chongqing and Hefei.MCAC Shunde: 38 product lines focusing on VRF (DC inverters and digital scroll products), split products, heat pump water heaters, and AHU/FCU.MCAC Chongqing: 14 product lines focusing on water cooled centrifugal/screw/scroll chillers, air cooled screw/scroll chillers, and AHU/FCU.MCAC Hefei: 11 product lines focusing on VRF, chillers, and heat pump water heaters.
Year
2000
2004
20062001 2013
2007
20101999
2011 2014
2014 Launched the All DC Inverter V5X globally2013 Launched the super high efficiency centrifugal chiller with full falling film technology2011 Launched the DC Inverter V4 Plus globally2010 Built the 3rd manufacturing base in Hefei2007 Won the first Midea centrifugal chiller project oversea2006 Launched the first VSD centrifugal chiller 2004 Acquired MGRE entered the chiller industry2001 Partnered with Copeland to develop the digital scroll VRF system2000 Developed the first inverter VRF With Toshiba1999 Entered the CAC field
Contents04
05
07
17
22
04
Product lineups
Nomenclature
Precision AC
Base station AC
Project references
Product lineups
Project references
Nom
enclatureP
roduct lineupsP
recision AC
Base station A
C
Project references
Nom
enclatureP
roduct lineupsP
recision AC
Base station A
C
PrecisionAC
Base staticonAC
MDP series(R22, R410A)
Micool DXair cool series(R22, R410A)
Compact type(R22,R407c customized)
Split type(R22, R410A customized)
With free cooling
Without free cooling
Front delivery (Up)Front intake (Down)
Top deliveryFront intake
Universaloutdoor unit
5.5kW 7.5kW 12.5kW
20.2~30.9kW 35kW
35kW
40.3~58.9kW 71.1~90.1kW
20.2~30.9kW 40.3~58.9kW 71.1~90.1kW
Underfloor deliveryTop intake
6.0kW,7.5kW 12.0kW
5.5kW 13.0kW
5.5kW 7.59kW
7.59kW
13.0kW
Contents04
05
07
17
22
04
Product lineups
Nomenclature
Precision AC
Base station AC
Project references
Product lineups
Project references
Nom
enclatureP
roduct lineupsP
recision AC
Base station A
C
Project references
Nom
enclatureP
roduct lineupsP
recision AC
Base station A
C
PrecisionAC
Base staticonAC
MDP series(R22, R410A)
Micool DXair cool series(R22, R410A)
Compact type(R22,R407c customized)
Split type(R22, R410A customized)
With free cooling
Without free cooling
Front delivery (Up)Front intake (Down)
Top deliveryFront intake
Universaloutdoor unit
5.5kW 7.5kW 12.5kW
20.2~30.9kW 35kW
35kW
40.3~58.9kW 71.1~90.1kW
20.2~30.9kW 40.3~58.9kW 71.1~90.1kW
Underfloor deliveryTop intake
6.0kW,7.5kW 12.0kW
5.5kW 13.0kW
5.5kW 7.59kW
7.59kW
13.0kW
NomenclaturePrecision AC
Air Cool Series
Midea
Power SupplyT: 380V~ 3Ph 50HzS: 220V~ 1Ph 50Hz
Compressor Quantity
Nominal Cooling Capacity (20kW)
Indoor Unit TypeU: Top delivery & front intakeD: Underfloor delivery & top intakeV: Front delivery & front intake
Series Number
Humidification FunctionS: With humidification function0: Without humidification function
Electric Heater Function1: With electric heater0: Without electric heater
Refrigerant TypeN: R410AR: R22
M A T 1 1 1020U N
Indoor unit:
Base Station AC
Nominal Cooling Capacity (6kW)
Series Number
Cooling with Electric Heater Type
Compact Type
Base Station AC
Power SupplyS: 380V~ 3Ph 50Hz
KC JZ60D S (E1)
Compact type:
Midea
Fan Quantity
Nominal Heat-exchange Capacity (33kW)
Refrigerant TypeN: R410AOmit: R22
1 N033MA
Outdoor unit:
Power SupplySC: 380V~ 3Ph 50HzCX: 220V~ 1Ph 50Hz
Floor Standing Type
Function Type1(R2): Without free cooling function2(R2): With free cooling function
55 JZCXL
Split Type - Indoor unit:
Nominal Cooling Capacity (5.5kW)
Split Type
Base Station AC
KF 1(R2)
Power SupplyC: 220V~ 1Ph 50Hz
Outdoor Unit
Series Number
55 210CW
Split Type - Outdoor unit:
Nominal Cooling Capacity (5.5kW)
Split Type
KF
05 06
Nom
enclature
Nom
enclature
S
NomenclaturePrecision AC
Air Cool Series
Midea
Power SupplyT: 380V~ 3Ph 50HzS: 220V~ 1Ph 50Hz
Compressor Quantity
Nominal Cooling Capacity (20kW)
Indoor Unit TypeU: Top delivery & front intakeD: Underfloor delivery & top intakeV: Front delivery & front intake
Series Number
Humidification FunctionS: With humidification function0: Without humidification function
Electric Heater Function1: With electric heater0: Without electric heater
Refrigerant TypeN: R410AR: R22
M A T 1 1 1020U N
Indoor unit:
Base Station AC
Nominal Cooling Capacity (6kW)
Series Number
Cooling with Electric Heater Type
Compact Type
Base Station AC
Power SupplyS: 380V~ 3Ph 50Hz
KC JZ60D S (E1)
Compact type:
Midea
Fan Quantity
Nominal Heat-exchange Capacity (33kW)
Refrigerant TypeN: R410AOmit: R22
1 N033MA
Outdoor unit:
Power SupplySC: 380V~ 3Ph 50HzCX: 220V~ 1Ph 50Hz
Floor Standing Type
Function Type1(R2): Without free cooling function2(R2): With free cooling function
55 JZCXL
Split Type - Indoor unit:
Nominal Cooling Capacity (5.5kW)
Split Type
Base Station AC
KF 1(R2)
Power SupplyC: 220V~ 1Ph 50Hz
Outdoor Unit
Series Number
55 210CW
Split Type - Outdoor unit:
Nominal Cooling Capacity (5.5kW)
Split Type
KF
05 06
Nom
enclature
Nom
enclature
S
07 08
FeaturesIDC rooms solutions
Higher reliable scroll compressor
High efficient evaporator, energy-saving dehumidify
Immersed electrode humidifier
Computer equipment in IDC rooms generates heat, and is sensitive to heat, humidity, and dust, but also the need for every high resilience and failover requirements. Maintaining a stable temperature and humidity within tight tolerances is critical to IT system reliability.Midea can supply this kind of precision air conditioner, the Micool and MDP series. They can control temperature, humidity and particle filtration within tight tolerances 24 hours a day and can be remotely monitored.
Famous brand, Copeland, high efficient scroll compressor.Built-in thermal multi-protectors that prevent motor overheating.Better liquid handing. Axial and radial compliance in compressor allow the scroll members to separate in the presence of liquid refrigerant to provide protection against liquid-refrigerant damage.No complex internal suction and discharge valves for quieter operation and higher reliability.Notes: Scroll comprossor is only available for Micool air cool series A/C.
High reliability, well-known brand, Carel.Adopt advantage control technology of immersed electrode humidifier. it can make the air conditioner more accuratedly control the relative humidity through the smart logic programs.Automatically self-cleaning, reduce the maintenance frequency of cylinder. Openable cylinder, quick click-on closing, with a reabber gasket to ensure perfect water- tightness between the two parts of cylinder.
Adopt V-shape evaporator, enlarge the heat exchanger surface.Inner grooved copper pipe, enhance the heat exchange ability.Change the valid evaporator’ s section by built-in electromagnetic valve to dehumidification without apparent temperature fluctuation.Inner grooved copper pipe
Traditional finAdvanced fin
0ºC 5ºC 20ºC
[60s`]
Special compressor
Normal compressor
Ambient temperature
Extend operating range
Improved 50% Improved 20%
Compressor efficiency
Precision AC
Precision A
C
07 08
FeaturesIDC rooms solutions
Higher reliable scroll compressor
High efficient evaporator, energy-saving dehumidify
Immersed electrode humidifier
Computer equipment in IDC rooms generates heat, and is sensitive to heat, humidity, and dust, but also the need for every high resilience and failover requirements. Maintaining a stable temperature and humidity within tight tolerances is critical to IT system reliability.Midea can supply this kind of precision air conditioner, the Micool and MDP series. They can control temperature, humidity and particle filtration within tight tolerances 24 hours a day and can be remotely monitored.
Famous brand, Copeland, high efficient scroll compressor.Built-in thermal multi-protectors that prevent motor overheating.Better liquid handing. Axial and radial compliance in compressor allow the scroll members to separate in the presence of liquid refrigerant to provide protection against liquid-refrigerant damage.No complex internal suction and discharge valves for quieter operation and higher reliability.Notes: Scroll comprossor is only available for Micool air cool series A/C.
High reliability, well-known brand, Carel.Adopt advantage control technology of immersed electrode humidifier. it can make the air conditioner more accuratedly control the relative humidity through the smart logic programs.Automatically self-cleaning, reduce the maintenance frequency of cylinder. Openable cylinder, quick click-on closing, with a reabber gasket to ensure perfect water- tightness between the two parts of cylinder.
Adopt V-shape evaporator, enlarge the heat exchanger surface.Inner grooved copper pipe, enhance the heat exchange ability.Change the valid evaporator’ s section by built-in electromagnetic valve to dehumidification without apparent temperature fluctuation.Inner grooved copper pipe
Traditional finAdvanced fin
0ºC 5ºC 20ºC
[60s`]
Special compressor
Normal compressor
Ambient temperature
Extend operating range
Improved 50% Improved 20%
Compressor efficiency
Precision AC
Precision A
C
09 10
High efficient indoor & outdoor motors
Accurate microprocessor control technology
Outdoor motor: Well-known brand, Ziehl-Abegg.According to different operating parameter, fan motor speeds can be automatically adjusted by frequency converter in electric box.Metal impeller, anti-corrosion design, made of die-cast aluminium.
Indoor motor:Standard - High efficient motor and FC fan. Fan speed can be adjusted through chaning different belt roller. Optional - EC fan motor, more efficient. It can automatically adjust running speed to ensure supply required air volume at different static pressure.
Indoor EC fan motor(Optional)
Indoor FC fan(Standard)
Double wall casing design, improve heat insulation
Heat-insulated casing can prevent the condensate from the unit body.Galvanized steel sheet of nitrogen treatment and powder spray coating make the casing of indoor unit anti-rust and fire resistance.
Empty
External
Internal
Reduce exchanged
heat.
Galvanized steel sheet
Powder spray coating
The valve is connected with the pipe of evaporator. When reducing the humidity, the valve will be switch off, and a part of evaporator will not be available. It will be fast to get rid of the water in air.
High sensitivity sensor can accurately detect the temperature and humidity of the condition and send the signal to the main control module.
Temperature & humidity sensor
One way electric valve Carel, high quality, humidity control module. It can receive and analyse the signal from humidity sensor and control the steam cylinder to make the relative humidity meet the requirement.
Humidity control module
Frequency converter is fixed in outdoor unit and connected with outdoor fan motor. It adopt vector control technology. The main control module of air conditioner according to the signal from all sensor, transform signal to frequency converter to adjust the outdoor fan motor speed.
Frequency converter
High quality sensor can accurately detect the pressure of the refrigerant system, and send the signal to the main control module.
Pressure sensor
High and low pressure protection.Discharge temperature protection.Lack of phase protection.Phase sequence protection.Water leakage protection.
Multiple protections
Easy maintenanceOnly open the door to all repair and maintain the units.Key components ( compressor, fan-motor, filter, main PCB board, etc. ) is designed to put in the front of indoor units.Rotalock type connection between compressor and pipes. when change the compressor, it is no need to welding.
Outdoor fan motor & Frequency converter
Multiple function control system The running parameter can be display in the screen of control panel when the air conditioner is in operating status.At least 100 pieces of error-records will be stored in the control system.Networking solution of Max. 8 units can be achieved.Rotary function, standby function, casecade function and conflict-management can be ensure the units keep operating in the whole year.Background monitoring system can be built. (Customized)
Rotary function
Start operation
Main unit Stops
Main Slave Slave Main
Runs Runs
Slave unit Stops Stops Runs
Casecade function
Start operation Slave unit runs.
Heat loadincreases.
Heat loadis normal.
Slave unit stops.
Main unit Runs
Slave unit Stops Stops Runs
Standby function
Start operation
Error on main unit.
Main unit Stops
Main Slave
Runs
Slave unit Stops Runs
Precision A
C
Precision A
C
Air plenum box as optional (Only for top delivery models)
Air filter as standard
Air plenum box as optional can change the direction of air flow. Air plenum bos with grill can ensure the evenness of air supply flow from the products.The grills in air plenum box can be adjusted by hand. It is very easy to set the direction of air supply flow.
Air filter, grade G2, is the standard for MDP series products.Air filter, grade G4, is the standard for Micool DX air cool series products.When the filter is too dirty, the unit will send the promoting message for cleaning the filter.
09 10
High efficient indoor & outdoor motors
Accurate microprocessor control technology
Outdoor motor: Well-known brand, Ziehl-Abegg.According to different operating parameter, fan motor speeds can be automatically adjusted by frequency converter in electric box.Metal impeller, anti-corrosion design, made of die-cast aluminium.
Indoor motor:Standard - High efficient motor and FC fan. Fan speed can be adjusted through chaning different belt roller. Optional - EC fan motor, more efficient. It can automatically adjust running speed to ensure supply required air volume at different static pressure.
Indoor EC fan motor(Optional)
Indoor FC fan(Standard)
Double wall casing design, improve heat insulation
Heat-insulated casing can prevent the condensate from the unit body.Galvanized steel sheet of nitrogen treatment and powder spray coating make the casing of indoor unit anti-rust and fire resistance.
Empty
External
Internal
Reduce exchanged
heat.
Galvanized steel sheet
Powder spray coating
The valve is connected with the pipe of evaporator. When reducing the humidity, the valve will be switch off, and a part of evaporator will not be available. It will be fast to get rid of the water in air.
High sensitivity sensor can accurately detect the temperature and humidity of the condition and send the signal to the main control module.
Temperature & humidity sensor
One way electric valve Carel, high quality, humidity control module. It can receive and analyse the signal from humidity sensor and control the steam cylinder to make the relative humidity meet the requirement.
Humidity control module
Frequency converter is fixed in outdoor unit and connected with outdoor fan motor. It adopt vector control technology. The main control module of air conditioner according to the signal from all sensor, transform signal to frequency converter to adjust the outdoor fan motor speed.
Frequency converter
High quality sensor can accurately detect the pressure of the refrigerant system, and send the signal to the main control module.
Pressure sensor
High and low pressure protection.Discharge temperature protection.Lack of phase protection.Phase sequence protection.Water leakage protection.
Multiple protections
Easy maintenanceOnly open the door to all repair and maintain the units.Key components ( compressor, fan-motor, filter, main PCB board, etc. ) is designed to put in the front of indoor units.Rotalock type connection between compressor and pipes. when change the compressor, it is no need to welding.
Outdoor fan motor & Frequency converter
Multiple function control system The running parameter can be display in the screen of control panel when the air conditioner is in operating status.At least 100 pieces of error-records will be stored in the control system.Networking solution of Max. 8 units can be achieved.Rotary function, standby function, casecade function and conflict-management can be ensure the units keep operating in the whole year.Background monitoring system can be built. (Customized)
Rotary function
Start operation
Main unit Stops
Main Slave Slave Main
Runs Runs
Slave unit Stops Stops Runs
Casecade function
Start operation Slave unit runs.
Heat loadincreases.
Heat loadis normal.
Slave unit stops.
Main unit Runs
Slave unit Stops Stops Runs
Standby function
Start operation
Error on main unit.
Main unit Stops
Main Slave
Runs
Slave unit Stops Runs
Precision A
C
Precision A
C
Air plenum box as optional (Only for top delivery models)
Air filter as standard
Air plenum box as optional can change the direction of air flow. Air plenum bos with grill can ensure the evenness of air supply flow from the products.The grills in air plenum box can be adjusted by hand. It is very easy to set the direction of air supply flow.
Air filter, grade G2, is the standard for MDP series products.Air filter, grade G4, is the standard for Micool DX air cool series products.When the filter is too dirty, the unit will send the promoting message for cleaning the filter.
1211
Precision AC - Micool DX air cool seriesR410AR410A R22R22
Outdoor ambient temperature range:
-20°C~45°C ( -34°C~45°C, Customized)Indoor ambient temperature range:
0°C~45°C
Notes: All the air plenum boxes are assembled on site.
Dimension (Air plenum box)
MF4010HM
MF6010HM
MF4015HM
MF6015HM
MF4020HM
MF6020HM
MF4030HM
MF6030HM
895mm 870mm 400mm 711.8mm 345.6mm 1
1
2
2
2
2
3
3
545.6mm
545.6mm
545.6mm
545.6mm
345.6mm
345.6mm
345.6mm
711.8mm
516.8mm
516.8mm
711.8mm
711.8mm
711.8mm
711.8mm
400mm
400mm
400mm
600mm
600mm
600mm
600mm
975mm
1,270mm
1,865mm
2,810mm
2,810mm
1,865mm
1,480mm
975mm
920mm
920mm
930mm
920mm
920mm
930mm
920mm
920mm
175mm
175mm
145mm
195mm
250mm
230mm
205mm
310mm 32.5kg 48.5kg
38.0kg 50.0kg
46.0kg 60.0kg
49.0kg 59.0kg
58.0kg 72.0kg
65.0kg 84.0kg
79.0kg 104.0kg
32.5kg24.5kg
870mm
870mm
870mm
870mm
870mm
870mm
870mm
895mm
1,400mm
1,400mm
1,790mm
1,790mm
2,685mm
2,685mm
ModelLength
Dimension (Assembled) Outlet grille
LengthWidth Width QuantityHeight Length
Packing
Width Height
Weight
Net Gross
20.2kW~30.9kW 34.0kW 40.3kW~59.1kW 71.1kW~90.1kW
Top delivery
Front intake
34.0kW 40.3kW~59.1kW 71.1kW~90.1kW20.2kW~30.9kW
Underfloor delivery
Top intake
Air plenum box
(Optional)
Specifications are subject to change without prior notice for product improvement.
[2] (In specification): Vertical installation of outdoor unit.
[1] (In specification): Horizontal installation of outdoor unit.
Cooling 24 17 35
Entering air DB (°C) Entering air DB (°C)Entering air WB (°C)
Indoor side Outdoor side
Nominal test condition (Temperature)
Universal
outdoor unit
MDP series
Specifications (R410A)
Specifications (R22)Indoor unit MAV006S1R2S
MA0071 MA0101 MA0101 MA0162
MAV008S1R2S MAV008T1R2S MAV013T1R2S
Outdoor unit
Power supply (Indoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-
Ф16.5
105/117
30/33 40/43 40/43 65/76
107/119 107/119 140/151
956×770×420
842×695×324 945×810×395 945×810×395 904×1,332×414
1,050×900×490 1,050×900×490 1,030×1,456×435
Ф16.5 Ф16.5 Ф16.5mm
mm
mm
kg
kg
Drainage pipe (OD)
Packing (W×H×D)
810×2,030×530 810×2,030×530 810×2,030×530 880×2,030×620mmPacking (W×H×D)
700×1,880×425 700×1,880×425 700×1,880×425 760×1,880×515mmDimension (W×H×D)
Dimension (W×H×D)
Indoor unit
Outdoor unit
Net/gross weight
Weight
5.5
4.95
1,550
3.5
2.5
5.6
27
Ф6/Ф12.7 Ф6/Ф16 Ф6/Ф16 Ф9.52/Ф19
32 18 23
6.7 6.7 9.4
2.5 2.5 2.5
3.5 3.5 4.0
2,050 2,050 2,950
3.003.003.003.00
7.5
6.75 6.75 11.25
7.5 12.5
Cooling
Total capacity kW
kW
kW
kW
A
mm
W/W
kg/h
Sensible capacity
EER
Air volume
Rated input
Humidification capacity
Rated current
Size (Liquid/gas)Rfrigerant pipe
Elect. heater input
m3/h
Notes:1. The nominal cooling capacity is based on the following conditons: Indoor temperature: 24°CDB, 17°CWB; Outdoor temperature: 35°CDB.2. If the refrigerant pipe length is less than 40m and more than 20m, the long-pipe accessories is necessary.3. Specifications are subject to change without prior notice for product improvement.
Front delivery, front intake 5.5kW, 7.5kW 12.5kW, 17kW
R410AR410A R22R22
Outdoor ambient temperature range:
-15°C~48°C
Indoor ambient temperature range:
0°C~40°C
Indoor unit MAV006S1N2S
MA0071N MA0101N MA0162N MA0212N
MAV008T1N2S MAV013T1N2S MAV018T1N2S
Outdoor unit
Power supply (Indoor unit) 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-
Ф16.5
105/117
30/33 40/43 65/76 89/106
107/119 140/151 190/208
956×770×420
842×695×324 945×810×395 904×1,332×414 1,120×1,558×528
1,050×900×490 1,030×1,456×435 1,270×1,720×565
Ф16.5 Ф16.5 Ф16.5mm
mm
mm
kg
kg
Drainage pipe (OD)
Packing (W×H×D)
810×2,030×530 810×2,030×530 880×2,030×620 920×2,030×775mmPacking (W×H×D)
700×1,880×425 700×1,880×425 760×1,880×515 800×1,880×670mmDimension (W×H×D)
Dimension (W×H×D)
Indoor unit
Outdoor unit
Net/gross weight
Weight
5.5
4.95
1,550
3.5
2.5
5.6
27
Ф6/Ф12.7 Ф6/Ф16 Ф9.52/Ф19 Ф9.52/Ф19
18 23 26
6.7 9.4 11.2
2.5 2.5 2.5
3.5 4.0 4.0
2,050 2,950 4,500
2.903.002.902.91
7.45
6.75 11.25 15.3
12.5 17.0
Cooling
Total capacity kW
kW
kW
kW
A
mm
W/W
kg/h
Sensible capacity
EER
Air volume
Rated input
Humidification capacity
Rated current
Size (Liquid/gas)Rfrigerant pipe
Elect. heater input
m3/h
Precision A
C
Precision A
C
1211
Precision AC - Micool DX air cool seriesR410AR410A R22R22
Outdoor ambient temperature range:
-20°C~45°C ( -34°C~45°C, Customized)Indoor ambient temperature range:
0°C~45°C
Notes: All the air plenum boxes are assembled on site.
Dimension (Air plenum box)
MF4010HM
MF6010HM
MF4015HM
MF6015HM
MF4020HM
MF6020HM
MF4030HM
MF6030HM
895mm 870mm 400mm 711.8mm 345.6mm 1
1
2
2
2
2
3
3
545.6mm
545.6mm
545.6mm
545.6mm
345.6mm
345.6mm
345.6mm
711.8mm
516.8mm
516.8mm
711.8mm
711.8mm
711.8mm
711.8mm
400mm
400mm
400mm
600mm
600mm
600mm
600mm
975mm
1,270mm
1,865mm
2,810mm
2,810mm
1,865mm
1,480mm
975mm
920mm
920mm
930mm
920mm
920mm
930mm
920mm
920mm
175mm
175mm
145mm
195mm
250mm
230mm
205mm
310mm 32.5kg 48.5kg
38.0kg 50.0kg
46.0kg 60.0kg
49.0kg 59.0kg
58.0kg 72.0kg
65.0kg 84.0kg
79.0kg 104.0kg
32.5kg24.5kg
870mm
870mm
870mm
870mm
870mm
870mm
870mm
895mm
1,400mm
1,400mm
1,790mm
1,790mm
2,685mm
2,685mm
ModelLength
Dimension (Assembled) Outlet grille
LengthWidth Width QuantityHeight Length
Packing
Width Height
Weight
Net Gross
20.2kW~30.9kW 34.0kW 40.3kW~59.1kW 71.1kW~90.1kW
Top delivery
Front intake
34.0kW 40.3kW~59.1kW 71.1kW~90.1kW20.2kW~30.9kW
Underfloor delivery
Top intake
Air plenum box
(Optional)
Specifications are subject to change without prior notice for product improvement.
[2] (In specification): Vertical installation of outdoor unit.
[1] (In specification): Horizontal installation of outdoor unit.
Cooling 24 17 35
Entering air DB (°C) Entering air DB (°C)Entering air WB (°C)
Indoor side Outdoor side
Nominal test condition (Temperature)
Universal
outdoor unit
MDP series
Specifications (R410A)
Specifications (R22)Indoor unit MAV006S1R2S
MA0071 MA0101 MA0101 MA0162
MAV008S1R2S MAV008T1R2S MAV013T1R2S
Outdoor unit
Power supply (Indoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-
Ф16.5
105/117
30/33 40/43 40/43 65/76
107/119 107/119 140/151
956×770×420
842×695×324 945×810×395 945×810×395 904×1,332×414
1,050×900×490 1,050×900×490 1,030×1,456×435
Ф16.5 Ф16.5 Ф16.5mm
mm
mm
kg
kg
Drainage pipe (OD)
Packing (W×H×D)
810×2,030×530 810×2,030×530 810×2,030×530 880×2,030×620mmPacking (W×H×D)
700×1,880×425 700×1,880×425 700×1,880×425 760×1,880×515mmDimension (W×H×D)
Dimension (W×H×D)
Indoor unit
Outdoor unit
Net/gross weight
Weight
5.5
4.95
1,550
3.5
2.5
5.6
27
Ф6/Ф12.7 Ф6/Ф16 Ф6/Ф16 Ф9.52/Ф19
32 18 23
6.7 6.7 9.4
2.5 2.5 2.5
3.5 3.5 4.0
2,050 2,050 2,950
3.003.003.003.00
7.5
6.75 6.75 11.25
7.5 12.5
Cooling
Total capacity kW
kW
kW
kW
A
mm
W/W
kg/h
Sensible capacity
EER
Air volume
Rated input
Humidification capacity
Rated current
Size (Liquid/gas)Rfrigerant pipe
Elect. heater input
m3/h
Notes:1. The nominal cooling capacity is based on the following conditons: Indoor temperature: 24°CDB, 17°CWB; Outdoor temperature: 35°CDB.2. If the refrigerant pipe length is less than 40m and more than 20m, the long-pipe accessories is necessary.3. Specifications are subject to change without prior notice for product improvement.
Front delivery, front intake 5.5kW, 7.5kW 12.5kW, 17kW
R410AR410A R22R22
Outdoor ambient temperature range:
-15°C~48°C
Indoor ambient temperature range:
0°C~40°C
Indoor unit MAV006S1N2S
MA0071N MA0101N MA0162N MA0212N
MAV008T1N2S MAV013T1N2S MAV018T1N2S
Outdoor unit
Power supply (Indoor unit) 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-
Ф16.5
105/117
30/33 40/43 65/76 89/106
107/119 140/151 190/208
956×770×420
842×695×324 945×810×395 904×1,332×414 1,120×1,558×528
1,050×900×490 1,030×1,456×435 1,270×1,720×565
Ф16.5 Ф16.5 Ф16.5mm
mm
mm
kg
kg
Drainage pipe (OD)
Packing (W×H×D)
810×2,030×530 810×2,030×530 880×2,030×620 920×2,030×775mmPacking (W×H×D)
700×1,880×425 700×1,880×425 760×1,880×515 800×1,880×670mmDimension (W×H×D)
Dimension (W×H×D)
Indoor unit
Outdoor unit
Net/gross weight
Weight
5.5
4.95
1,550
3.5
2.5
5.6
27
Ф6/Ф12.7 Ф6/Ф16 Ф9.52/Ф19 Ф9.52/Ф19
18 23 26
6.7 9.4 11.2
2.5 2.5 2.5
3.5 4.0 4.0
2,050 2,950 4,500
2.903.002.902.91
7.45
6.75 11.25 15.3
12.5 17.0
Cooling
Total capacity kW
kW
kW
kW
A
mm
W/W
kg/h
Sensible capacity
EER
Air volume
Rated input
Humidification capacity
Rated current
Size (Liquid/gas)Rfrigerant pipe
Elect. heater input
m3/h
Precision A
C
Precision A
C
13 14
Indoor unit MAU070T2N1S1 MAU080T2N1S1 MAU090T2N1S1
MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.5
65.78
42.0
19,600
12
10
R410A
935/1,125 950/1,140 960/1,150
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R410A R410A
10 10
12 12
22,200 23,800
48.0 55.0
98.085.074.0
78.8
70.92 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAU040T2N1S1 MAU045T1N1S1 MAU050T2N1S1 MAU060T2N1S1
MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
37.08
32.0
10,980
9
10
R410A
620/770 565/715 670/820 680/830
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R410A R410A R410A
10 10 10
9 9 9
12,030 13,500 16,200
33.0 36.0 39.0
70.065.062.060.0
45.3
40.77 45.99 53.01
51.1 58.9Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R410A, Top delivery/front intake)Indoor unit MAU020T1N1S1 MAU025T1N1S1 MAU030T1N1S1 MAU035T1N1S1
MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,125
6
5
R410A
340/425 365/445 370/450 510/620
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R410A R410A R410A
5 5 5
6 6 6
6,810 8,525 10,000
16.5 18.5 25.0
46.033.030.026.8
25.6
23.04 26.55 32.20
29.7 35.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD070T2N1S1 MAD080T2N1S1 MAD090T2N1S1
MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.1
67.55
42.0
20,800
12
10
R410A
890/1,080 905/1,095 915/1,105
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R410A R410A
10 10
12 12
23,300 24,800
48.0 55.0
98.085.074.0
81.1
73.80 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD040T2N1S1 MAD045T1N1S1 MAD050T2N1S1 MAD060T2N1S1
MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
38.29
32.0
11,980
9
10
R410A
610/760 560/710 660/810 670/820
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R410A R410A R410A
10 10 10
9 9 9
13,030 14,500 17,000
33.0 36.0 39.0
70.065.062.060.0
44.9
41.31 45.23 53.19
49.7 59.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R410A, Underfloor delivery/top intake)Indoor unit MAD020T1N1S1 MAD025T1N1S1 MAD030T1N1S1 MAD035T1N1S1
MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,225
6
5
R410A
340/425 360/440 365/445 500/610
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R410A R410A R410A
5 5 5
6 6 6
7,010 8,825 10,400
16.5 18.5 25
46333026.8
26.0
23.92 27.81 31.28
30.9 34.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Precision A
C
Precision A
C
13 14
Indoor unit MAU070T2N1S1 MAU080T2N1S1 MAU090T2N1S1
MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.5
65.78
42.0
19,600
12
10
R410A
935/1,125 950/1,140 960/1,150
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R410A R410A
10 10
12 12
22,200 23,800
48.0 55.0
98.085.074.0
78.8
70.92 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAU040T2N1S1 MAU045T1N1S1 MAU050T2N1S1 MAU060T2N1S1
MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
37.08
32.0
10,980
9
10
R410A
620/770 565/715 670/820 680/830
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R410A R410A R410A
10 10 10
9 9 9
12,030 13,500 16,200
33.0 36.0 39.0
70.065.062.060.0
45.3
40.77 45.99 53.01
51.1 58.9Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R410A, Top delivery/front intake)Indoor unit MAU020T1N1S1 MAU025T1N1S1 MAU030T1N1S1 MAU035T1N1S1
MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,125
6
5
R410A
340/425 365/445 370/450 510/620
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R410A R410A R410A
5 5 5
6 6 6
6,810 8,525 10,000
16.5 18.5 25.0
46.033.030.026.8
25.6
23.04 26.55 32.20
29.7 35.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD070T2N1S1 MAD080T2N1S1 MAD090T2N1S1
MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.1
67.55
42.0
20,800
12
10
R410A
890/1,080 905/1,095 915/1,105
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R410A R410A
10 10
12 12
23,300 24,800
48.0 55.0
98.085.074.0
81.1
73.80 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD040T2N1S1 MAD045T1N1S1 MAD050T2N1S1 MAD060T2N1S1
MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
38.29
32.0
11,980
9
10
R410A
610/760 560/710 660/810 670/820
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R410A R410A R410A
10 10 10
9 9 9
13,030 14,500 17,000
33.0 36.0 39.0
70.065.062.060.0
44.9
41.31 45.23 53.19
49.7 59.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R410A, Underfloor delivery/top intake)Indoor unit MAD020T1N1S1 MAD025T1N1S1 MAD030T1N1S1 MAD035T1N1S1
MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,225
6
5
R410A
340/425 360/440 365/445 500/610
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R410A R410A R410A
5 5 5
6 6 6
7,010 8,825 10,400
16.5 18.5 25
46333026.8
26.0
23.92 27.81 31.28
30.9 34.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Precision A
C
Precision A
C
15 16
Indoor unit MAU070T2R1S3 MAU080T2R1S3 MAU090T2R1S3
MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.5
65.78
42.0
19,600
12
10
R22
935/1,125 950/1,140 960/1,150
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R22 R22
10 10
12 12
22,200 23,800
48.0 55.0
98.085.074.0
78.8
70.92 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAU040T2R1S3 MAU045T1R1S3 MAU050T2R1S3 MAU060T2R1S3
MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
37.08
32.0
10,980
9
10
R22
620/770 565/715 670/820 680/830
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R22 R22 R22
10 10 10
9 9 9
12,030 13,500 16,200
33.0 36.0 39.0
70.065.062.060.0
45.3
40.77 45.99 53.01
51.1 58.9Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R22, Top delivery/front intake)Indoor unit MAU020T1R1S1 MAU025T1R1S3 MAU030T1R1S3 MAU035T1R1S3
MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,125
6
5
R22
340/425 365/445 370/450 510/620
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R22 R22 R22
5 5 5
6 6 6
6,810 8,525 10,000
16.5 18.5 25.0
46.033.030.026.8
25.6
23.04 26.55 32.20
29.7 35.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD070T2R1S3 MAD080T2R1S3 MAD090T2R1S3
MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.1
67.55
42.0
20,800
12
10
R22
890/1,080 905/1,095 915/1,105
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R22 R22
10 10
12 12
23,300 24,800
48.0 55.0
98.085.074.0
81.1
73.80 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD040T2R1S3 MAD045T1R1S3 MAD050T2R1S3 MAD060T2R1S3
MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
38.29
32.0
11,980
9
10
R22
610/760 560/710 660/810 670/820
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R22 R22 R22
10 10 10
9 9 9
13,030 14,500 17,000
33.0 36.0 39.0
70.065.062.060.0
44.9
41.31 45.23 53.19
49.7 59.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R22, Underfloor delivery/top intake)Indoor unit MAD020T1R1S1 MAD025T1R1S3 MAD030T1R1S3 MAD035T1R1S3
MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,225
6
5
R22
340/425 360/440 365/445 500/610
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R22 R22 R22
5 5 5
6 6 6
7,010 8,825 10,400
16.5 18.5 25.0
46.033.030.026.8
26.0
23.92 27.81 31.28
30.9 34.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Precision A
C
Precision A
C
15 16
Indoor unit MAU070T2R1S3 MAU080T2R1S3 MAU090T2R1S3
MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.5
65.78
42.0
19,600
12
10
R22
935/1,125 950/1,140 960/1,150
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R22 R22
10 10
12 12
22,200 23,800
48.0 55.0
98.085.074.0
78.8
70.92 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAU040T2R1S3 MAU045T1R1S3 MAU050T2R1S3 MAU060T2R1S3
MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
37.08
32.0
10,980
9
10
R22
620/770 565/715 670/820 680/830
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R22 R22 R22
10 10 10
9 9 9
12,030 13,500 16,200
33.0 36.0 39.0
70.065.062.060.0
45.3
40.77 45.99 53.01
51.1 58.9Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R22, Top delivery/front intake)Indoor unit MAU020T1R1S1 MAU025T1R1S3 MAU030T1R1S3 MAU035T1R1S3
MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,125
6
5
R22
340/425 365/445 370/450 510/620
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R22 R22 R22
5 5 5
6 6 6
6,810 8,525 10,000
16.5 18.5 25.0
46.033.030.026.8
25.6
23.04 26.55 32.20
29.7 35.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD070T2R1S3 MAD080T2R1S3 MAD090T2R1S3
MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
71.1
67.55
42.0
20,800
12
10
R22
890/1,080 905/1,095 915/1,105
1,660×1,290×690 1,980×1,290×690
220/330170/300150/260
2,685×1,971×8702,685×1,971×8702,685×1,971×870
2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290
2,480×1,290×690
R22 R22
10 10
12 12
23,300 24,800
48.0 55.0
98.085.074.0
81.1
73.80 81.09
90.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm
Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Indoor unit MAD040T2R1S3 MAD045T1R1S3 MAD050T2R1S3 MAD060T2R1S3
MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
40.3
38.29
32.0
11,980
9
10
R22
610/760 560/710 660/810 670/820
1,470×988×690 1,980×1,290×690
140/240105/210170/300105/190
1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870
1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290
1,470×988×690 1,660×1,290×690
R22 R22 R22
10 10 10
9 9 9
13,030 14,500 17,000
33.0 36.0 39.0
70.065.062.060.0
44.9
41.31 45.23 53.19
49.7 59.1Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm
Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Specification (R22, Underfloor delivery/top intake)Indoor unit MAD020T1R1S1 MAD025T1R1S3 MAD030T1R1S3 MAD035T1R1S3
MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
kg
Dimension (W×H×D)
Dimension (W×H×D) [1]
Dimension (W×H×D) [2]
Indoor unit
Outdoor unit
Net/gross weight
Net weight
20.2
18.58
15.0
6,225
6
5
R22
340/425 360/440 365/445 500/610
1,470×988×690 1,470×988×690
150/260140/240105/210105/190
895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870
1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290
1,660×1,290×690 1,660×1,290×690
R22 R22 R22
5 5 5
6 6 6
7,010 8,825 10,400
16.5 18.5 25.0
46.033.030.026.8
26.0
23.92 27.81 31.28
30.9 34.0Cooling
Total capacity kW
kW
kW
-
A
mm
Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm
Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm
mm
kW
kg/h
Sensible capacity
Air volume
Rated input
Humidification capacity
Rated current
Refrigerant type
Elect. heater input
m3/h
Precision A
C
Precision A
C
17
Base station AC
FeaturesBase station solutionsBase station is normally used in the context of mobile telephony, wireless computer networking and other wireless communications and in land surveying. Telecommunication system usually using containers, machines rooms faces special challenges on air conditioning. Normally the equipments in stations generate heat. So it is important that maintaining a stable temperature is critical to equipments reliability.Midea can supply this kind of air conditioner, split type and compact type. They can control temperature within tight tolerances 24 hours a day.
Base station ACNormal AC
Sensible capacityLatent capacity
Big airflow, high sensible heat ratioAdopt high-temperature-airflow and low-enthalpy design to avoid the threat of condensation in device surface.High-sensible-heat-ratio design, energy is saved.More save, more reliable.
Free cooling functionIndoor side is designed with free cooling function. it can help to save more energy.Down side air supply to take full removal of heat load and eliminating local hot spots.
Indoor sideOutdoor side
Air exchangeouttake
Fresh air intake
Air supplyouttake
Built-in compressor in indoor sideBuilt-in compressor in indoor side, the operating condition of compressor and reliability of system is apparently improved.
Long piping lengthThe outdoor unit is available for installation of any well ventilation location.
Notes: This is only available for split type units.
25mMax. equivalent piping length
Permitted value
10m
5mMax. height drop
Height drop betweenindoor unit and outdoor unit
Outdoor unit is up
Outdoor unit is down
Base station A
C
18
17
Base station AC
FeaturesBase station solutionsBase station is normally used in the context of mobile telephony, wireless computer networking and other wireless communications and in land surveying. Telecommunication system usually using containers, machines rooms faces special challenges on air conditioning. Normally the equipments in stations generate heat. So it is important that maintaining a stable temperature is critical to equipments reliability.Midea can supply this kind of air conditioner, split type and compact type. They can control temperature within tight tolerances 24 hours a day.
Base station ACNormal AC
Sensible capacityLatent capacity
Big airflow, high sensible heat ratioAdopt high-temperature-airflow and low-enthalpy design to avoid the threat of condensation in device surface.High-sensible-heat-ratio design, energy is saved.More save, more reliable.
Free cooling functionIndoor side is designed with free cooling function. it can help to save more energy.Down side air supply to take full removal of heat load and eliminating local hot spots.
Indoor sideOutdoor side
Air exchangeouttake
Fresh air intake
Air supplyouttake
Built-in compressor in indoor sideBuilt-in compressor in indoor side, the operating condition of compressor and reliability of system is apparently improved.
Long piping lengthThe outdoor unit is available for installation of any well ventilation location.
Notes: This is only available for split type units.
25mMax. equivalent piping length
Permitted value
10m
5mMax. height drop
Height drop betweenindoor unit and outdoor unit
Outdoor unit is up
Outdoor unit is down
Base station A
C
18
2019
Wide operating ambient temperature rangeThe operating ambient temperature range of units with free cooling is from -40°C to 45°C.The operating ambient temperature range of units without free cooling is from -15°C to 45°C.
Adopt RS485 standard communication protocol, long-distance centralized control is realized.Bulit-in many protections function and malfunction alarm function, more reliable and stable operation.The limit of upper and lower temperature can be set through the operator in indoor unit to ensure the temperature remains steady in the pre-set temperature range.The function of temperature locked can be used to restricts unintended operation.Multi-functions, include dual-unit-switch function, auto-restart function, standby function, join-in function and rotary function, can be ensure the units keep normally operating in the whole year.
Multi-electronic control technology
Outdoor ambient temperature °C(D.B.)
-40°C
45°C
45°C
-40 -30 -20 -10 10 20 30 40 500
-15°C
Units with free cooling
Units without free cooling
Outdoor ambient temperature
Outdoor ambient temperature
Rotary function
Start operation
Stops
Main Slave Slave Main
Runs RunsMain unit
Slave unit Stops Stops Runs
Join-in function
Start operation Slave unit runs. Slave unit stops.
RunsMain unit
Slave unit
Heat loadincreases.
Heat loadis normal.
Stops Stops Runs
Standby function
Start operation
Stops
Main Slave
RunsMain unit
Slave unit
Error on main unit.
Stops Runs
Base station AC
Split typewith free cooling
OptionalStandard R410AR410AR22R22
5.5kW 13.0kW7.59kW
Split type without free cooling
OptionalStandard R410AR410AR22R22
5.5kW 13.0kW7.59kW
Compact typewith free cooling
OptionalStandard R407CR407CR22R22
6.0kW,7.5kW 12.0kW
Specifications - Compact typeKCD-60L/S-JZ(E1) KCD-75L/S-JZ(E2) KCD-120L/S-JZModel
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
Throttle type
Dimension (W×H×D)
Packing (W×H×D)Unit
Net/Gross weight
5.70
6.0
1,824
3.29
1,550
3.45
15
R22
1,025×1,930×675 1,025×1,930×675
270/285205/220205/220
CapillaryCapillaryCapillary
1,250×1,900×6001,000×1,900×600 1,000×1,900×600
1,280×1,930×675
R22 R22
8.2 15.2
3.60 5.90
1,700 2,300
2.90 2.80
3.513.503.35
6.66
7.5
2.580 4,280
9.12
12.0
Cooling
Total capacity kW
kW
kW
-
-
mm
W
kW
W/W
A
Sensible capacity
Elect. heater
Input
EER
Air volume
Rated current
Refrigerant type
Rated input
m3/h
Specifications are subject to change without prior notice for product improvement.
Cooling 28 20 2635
Entering air DB (°C) Entering air WB (°C)Entering air DB (°C)Entering air WB (°C)
Indoor side Outdoor side
Nominal test condition (Temperature)
Base station A
C
Base station A
C
2019
Wide operating ambient temperature rangeThe operating ambient temperature range of units with free cooling is from -40°C to 45°C.The operating ambient temperature range of units without free cooling is from -15°C to 45°C.
Adopt RS485 standard communication protocol, long-distance centralized control is realized.Bulit-in many protections function and malfunction alarm function, more reliable and stable operation.The limit of upper and lower temperature can be set through the operator in indoor unit to ensure the temperature remains steady in the pre-set temperature range.The function of temperature locked can be used to restricts unintended operation.Multi-functions, include dual-unit-switch function, auto-restart function, standby function, join-in function and rotary function, can be ensure the units keep normally operating in the whole year.
Multi-electronic control technology
Outdoor ambient temperature °C(D.B.)
-40°C
45°C
45°C
-40 -30 -20 -10 10 20 30 40 500
-15°C
Units with free cooling
Units without free cooling
Outdoor ambient temperature
Outdoor ambient temperature
Rotary function
Start operation
Stops
Main Slave Slave Main
Runs RunsMain unit
Slave unit Stops Stops Runs
Join-in function
Start operation Slave unit runs. Slave unit stops.
RunsMain unit
Slave unit
Heat loadincreases.
Heat loadis normal.
Stops Stops Runs
Standby function
Start operation
Stops
Main Slave
RunsMain unit
Slave unit
Error on main unit.
Stops Runs
Base station AC
Split typewith free cooling
OptionalStandard R410AR410AR22R22
5.5kW 13.0kW7.59kW
Split type without free cooling
OptionalStandard R410AR410AR22R22
5.5kW 13.0kW7.59kW
Compact typewith free cooling
OptionalStandard R407CR407CR22R22
6.0kW,7.5kW 12.0kW
Specifications - Compact typeKCD-60L/S-JZ(E1) KCD-75L/S-JZ(E2) KCD-120L/S-JZModel
Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
Throttle type
Dimension (W×H×D)
Packing (W×H×D)Unit
Net/Gross weight
5.70
6.0
1,824
3.29
1,550
3.45
15
R22
1,025×1,930×675 1,025×1,930×675
270/285205/220205/220
CapillaryCapillaryCapillary
1,250×1,900×6001,000×1,900×600 1,000×1,900×600
1,280×1,930×675
R22 R22
8.2 15.2
3.60 5.90
1,700 2,300
2.90 2.80
3.513.503.35
6.66
7.5
2.580 4,280
9.12
12.0
Cooling
Total capacity kW
kW
kW
-
-
mm
W
kW
W/W
A
Sensible capacity
Elect. heater
Input
EER
Air volume
Rated current
Refrigerant type
Rated input
m3/h
Specifications are subject to change without prior notice for product improvement.
Cooling 28 20 2635
Entering air DB (°C) Entering air WB (°C)Entering air DB (°C)Entering air WB (°C)
Indoor side Outdoor side
Nominal test condition (Temperature)
Base station A
C
Base station A
C
21 22
Specifications - Split type indoor unit with free coolingKF-55L/CX-JZ2(R2) KF-75L/SC-JZ2(R2) KF-130L/SC-JZ2(R2)Model
Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
Liquid/Gas pipe size
Dimension (W×H×D)
Packing (W×H×D)Indoor unit
Net/Gross weight
4.51
5.5
1,666
3.30
1,200
2.13
11.7
R22
810×1,920×720 810×1,920×720
134/146114/12496/106
Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7
Electric expansion valveElectric expansion valveElectric expansion valve
855×1,880×690700×1,880×610 700×1,880×610
875×1,920×795
R22 R22
6.7 12.0
3.20 5.30
1,700 2,850
3.30 3.35
6.072
7.59
2.300 3,880
10.4
13.0
Cooling
Total capacity kW
kW
kW
-
-
mm
mm
W
W/W
A
Sensible capacity
Input
EER
Air volume
Rated current
Refrigerant type
Throttle type
Rated input
m3/h
Specifications - Split type indoor unit without free coolingKF-55L/CX-JZ1(R2) KF-75L/SC-JZ1(R2) KF-130L/SC-JZ1(R2)Model
Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
Liquid/Gas pipe size
Dimension (W×H×D)
Packing (W×H×D)Indoor unit
Net/Gross weight
4.51
5.5
1,666
3.30
1,200
2.13
11.7
R22
810×1,640×530 810×1,640×530
126/13694.5/103.577/86
Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7
Electric expansion valveElectric expansion valveElectric expansion valve
855×1,660×505700×1,600×425 700×1,600×425
875×1,700×615
R22 R22
6.7 12.0
3.20 5.30
1,700 2,850
3.30 3.35
6.072
7.59
2.300 3,880
10.4
13.0
Cooling
Total capacity kW
kW
kW
-
-
mm
mm
W
W/W
A
Sensible capacity
Input
EER
Air volume
Rated current
Refrigerant type
Throttle type
Rated input
m3/h
Specifications - Universal outdoor unitKF-55W/C-210 KF-75W/C-350 KF-130W/C-610Model
Power supply 220V~, 1Ph, 50Hz220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-
mm
kg
Liquid/Gas pipe size
Dimension (W×H×D)
Packing (W×H×D)Outdoor unit
Net/Gross weight
0.46
0.105
R22
2,365
965×755×420 1,050×870×490
65/7339.5/45.627/32
Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7
904×1,332×414842×695×324 945×810×395
1,016×1,377×435
3,600 6,430
0.65
0.170
R22 R22
1.70
0.380Rated input kW
A
mm
mm
W
Rated current
Air volume
Refrigerant type
m3/h
Project references
Base station A
C
21 22
Specifications - Split type indoor unit with free coolingKF-55L/CX-JZ2(R2) KF-75L/SC-JZ2(R2) KF-130L/SC-JZ2(R2)Model
Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
Liquid/Gas pipe size
Dimension (W×H×D)
Packing (W×H×D)Indoor unit
Net/Gross weight
4.51
5.5
1,666
3.30
1,200
2.13
11.7
R22
810×1,920×720 810×1,920×720
134/146114/12496/106
Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7
Electric expansion valveElectric expansion valveElectric expansion valve
855×1,880×690700×1,880×610 700×1,880×610
875×1,920×795
R22 R22
6.7 12.0
3.20 5.30
1,700 2,850
3.30 3.35
6.072
7.59
2.300 3,880
10.4
13.0
Cooling
Total capacity kW
kW
kW
-
-
mm
mm
W
W/W
A
Sensible capacity
Input
EER
Air volume
Rated current
Refrigerant type
Throttle type
Rated input
m3/h
Specifications - Split type indoor unit without free coolingKF-55L/CX-JZ1(R2) KF-75L/SC-JZ1(R2) KF-130L/SC-JZ1(R2)Model
Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-
mm
kg
Liquid/Gas pipe size
Dimension (W×H×D)
Packing (W×H×D)Indoor unit
Net/Gross weight
4.51
5.5
1,666
3.30
1,200
2.13
11.7
R22
810×1,640×530 810×1,640×530
126/13694.5/103.577/86
Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7
Electric expansion valveElectric expansion valveElectric expansion valve
855×1,660×505700×1,600×425 700×1,600×425
875×1,700×615
R22 R22
6.7 12.0
3.20 5.30
1,700 2,850
3.30 3.35
6.072
7.59
2.300 3,880
10.4
13.0
Cooling
Total capacity kW
kW
kW
-
-
mm
mm
W
W/W
A
Sensible capacity
Input
EER
Air volume
Rated current
Refrigerant type
Throttle type
Rated input
m3/h
Specifications - Universal outdoor unitKF-55W/C-210 KF-75W/C-350 KF-130W/C-610Model
Power supply 220V~, 1Ph, 50Hz220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-
mm
kg
Liquid/Gas pipe size
Dimension (W×H×D)
Packing (W×H×D)Outdoor unit
Net/Gross weight
0.46
0.105
R22
2,365
965×755×420 1,050×870×490
65/7339.5/45.627/32
Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7
904×1,332×414842×695×324 945×810×395
1,016×1,377×435
3,600 6,430
0.65
0.170
R22 R22
1.70
0.380Rated input kW
A
mm
mm
W
Rated current
Air volume
Refrigerant type
m3/h
Project references
Base station A
C
23 24
China Unicom
Shijiazhuang customs China Mobile
Hebei Provincial Administration of Quality and Technical Supervision
Shenzhen North Railway Station
Project references
1508-1T1412
COMMERCIAL AIR CONDITIONERS
Precision AC / Base Station AC
Precision A
C / B
ase Station A
C
D e a l e r i n f o r m a t i o n
Commercial Air Conditioner Business Units
Midea Group
Add: West Region of Midea Commercial Air Conditioner Department, Industry Avenue,
Beijiao, Shunde, Foshan, Guangdong, P. R. China
Postal code: 528311
Tel: +86-757-26338346 Fax: +86-757-22390205
http://global.midea.com.cn
http://www.midea.com
Note: The data in this book may be changed without notice for further improvement
on quality and performance.
Ver.2014.12