39
Asbestos Assessment Report Residential Structure – 1530 W Bramlett Road Greenville, South Carolina S&ME Project No. 4226-18-003 Phase 49 PREPARED FOR: Greenville County 301 University Ridge, Suite 4100 Greenville, South Carolina, 29601 PREPARED BY: S&ME, Inc. 48 Brookfield Oaks Drive, Suite F Greenville, SC 29607 December 27, 2018 Inspection Performed by: Taylor Williams SCDHEC License BI-01602 Inspection Date: November 30, 2018 Asbestos Identified No Asbestos Design Required No Asbestos Air Monitoring Required No Attachment B

1530 W Bramlett Rd Asbestos Report - Greenville County

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 W Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003 Phase 49

PREPARED FOR:

Greenville County

301 University Ridge, Suite 4100

Greenville, South Carolina, 29601

PREPARED BY:

S&ME, Inc.

48 Brookfield Oaks Drive, Suite F

Greenville, SC 29607

December 27, 2018

Inspection Performed by:

Taylor Williams

SCDHEC License BI-01602

Inspection Date: November 30, 2018

Asbestos Identified No

Asbestos Design Required No

Asbestos Air Monitoring Required No

Attachment B

Page 2: 1530 W Bramlett Rd Asbestos Report - Greenville County

S&ME, Inc. | 48 Brookfield Oaks Drive, Suite F | Greenville, SC 29607 | p 864.297.9944 | www.smeinc.com

December 27, 2018

Greenville County

301 University Ridge, Suite 4100

Greenville, South Carolina 29601

Attention: Ms. Jessica Jordan

Reference: Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

Dear Ms. Jordan:

S&ME, Inc. (S&ME) has completed an asbestos assessment for the referenced property. The purpose of the

assessment is to identify asbestos-containing materials (ACMs) in the structure prior to demolition. Our

assessment was conducted in general accordance with our Proposal Number 42-1600890 dated July 20, 2016.

This work was authorized by the Greenville County Task Order # 05, dated August 1, 2018.

S&ME appreciates the opportunity to provide our asbestos assessment services to Greenville County. Please

contact us at your convenience if there are questions regarding the information contained in this report.

Sincerely,

S&ME, Inc.

Brian Mulholland Sherman Woodson, CIH, CSP

Staff Professional Senior Industrial Hygienist

[email protected] [email protected]

BM/SW T:\Projects\2018\ENV\4226-18-003_Greenville County Asbestos_Various Residents\Working_Documents\Phase 49 - 1530 W Bramlett

Road ACM\1530 W Bramlett Rd Asbestos Report.docx

Page 3: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

December 27, 2018 ii

Table of Contents

1.0 Executive Summary .......................................................................................................... 1

2.0 Introduction ....................................................................................................................... 2

3.0 Site And Project Descriptions ........................................................................................ 2

3.1 Purpose ............................................................................................................................................ 2

3.2 Site Description ............................................................................................................................... 2

4.0 Asbestos Assessment ........................................................................................................ 3

4.1 Sampling and Analysis .................................................................................................................. 3

4.2 Assessment ...................................................................................................................................... 3

4.3 Findings and Results ...................................................................................................................... 4

5.0 Conclusions and Recommendations ............................................................................. 4

6.0 Assumptions and Limitations ........................................................................................ 4

Appendices Appendix I – Figures and Photographs

Appendix II – Table 1 – Summary of Asbestos Results

Appendix III – Asbestos Laboratory Reports

Appendix IV – Copy of Inspector’s License

Page 4: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

December 27, 2018 1

Executive Summary

S&ME performed an asbestos assessment of the structure located at 1530 West Bramlett Road in Greenville,

South Carolina. The assessment was conducted by S&ME on November 30, 2018. This Executive Summary is

intended as an overview for the convenience of the reader. The complete report must be reviewed in its entirety

prior to making decisions regarding this site.

The subject structure is an approximately 800 square foot (SF) single-story residence built over a crawl space. We

understand the structure is scheduled for demolition. The interior is finished with drywall ceilings, wood panel

walls, vinyl floor tile, and vinyl sheet flooring. Exterior materials include metal siding, metal framed windows, and

a rubber membrane roof.

In addition two storage sheds are located on the property. The red storage shed consists of wood siding with roof

shingles and associated felt paper. The gray storage shed consists of vinyl siding with roof shingles and associated

felt paper.

The asbestos assessment included bulk sampling and laboratory analysis of suspect ACMs associated with the

interior and exterior of the structures. A total of 21 samples were collected including drywall with textured

material, vinyl sheet flooring, vinyl stick on flooring, and a rubber membrane roof.

The Environmental Protection Agency (EPA) and South Carolina Department of Health and Environmental Control

(SCDHEC) define materials as asbestos-containing (ACMs) if an asbestos content of one percent or greater (> 1%)

is detected in a representative sample.

No asbestos-containing materials were identified in the residential structure, or two storage shed structures.

This summary is for convenience only and should not be relied upon without first reading the full contents of this

report, including appended materials.

Page 5: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

December 27, 2018 2

1.0 Introduction

S&ME was contracted by Greenville County to perform an asbestos assessment of the structure located at 1530

West Bramlett Road in Greenville, South Carolina. S&ME performed the asbestos assessment on November 30,

2018. This assessment consisted of observing for, sampling, and analyzing suspect ACM that may be disturbed

during future demolition.

The scope of this assessment fulfills the requirements of the United States Environmental Protection Agency

(USEPA) National Emissions Standards for Hazardous Air Pollutants (NESHAPS) asbestos regulation, 40 CFR, Part

61, Subpart M, and SCDHEC Regulation 61-86.1, which requires an asbestos assessment of buildings scheduled for

renovation or demolition.

2.0 Site and Project Descriptions

2.1 Purpose

The assessment was performed to identify ACMs, prior to disturbing building materials during demolition

activities. The assessment included the interior and exterior of the building including roofing materials of the

residential structure located on the property. No additional structures were observed on the property. An

assessment strategy appropriate for this purpose was presented in our proposal and this report should be

interpreted only with regard to the specific purpose indicated.

2.2 Site Description

The subject structure is an approximately 800 square foot (SF) single-story residence built over a crawl space. We

understand the structure is scheduled for demolition. The interior is finished with drywall ceilings, wood panel

walls, vinyl floor tile, and vinyl sheet flooring. Exterior materials include metal siding, metal framed windows, and

a rubber membrane roof. Rock wool insulation is present in the attic. Fiberglass insulation is present on the HVAC

duct work.

In addition two storage sheds are located on the property. The red storage shed consists of wood siding with roof

shingles and associated felt paper. The gray storage shed consists of vinyl siding with roof shingles and associated

felt paper.

Non-suspect materials observed and not sampled in the building include: glass, cement, fiberglass insulation, rock

wool insulation, and concrete.

The general layout of the structure is depicted in Figure 1 in Appendix I. Photographs of the suspect samples are

also included in Appendix I. Table 1, Asbestos Results Summary, is found in Appendix II, and presents a summary

of the suspect materials, material friability, condition, potential for disturbance, quantity, and asbestos analysis of

the samples collected. The laboratory results are located in Appendix II.

Page 6: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

December 27, 2018 3

3.0 Asbestos Assessment

3.1 Sampling and Analysis

The assessment was performed by observing and sampling suspect ACMs associated with the accessible areas of

the subject building. The possibility exists that suspect materials were undetected in inaccessible areas such as

wall voids. If additional suspect ACMs not identified in this report are discovered during destructive activities, bulk

samples must be collected by a SCDHEC licensed inspector and analyzed for asbestos content prior to disturbance

or disposal of the suspect materials.

A sampling strategy was developed to provide representative samples in accordance with the SCDHEC and the

EPA. Bulk samples of suspect ACMs were collected by an SCDHEC licensed inspector. The bulk PLM and TEM

samples were submitted through chain-of-custody procedures to Eurofins CEI asbestos laboratory in Cary, North

Carolina for analysis of asbestos type and content. The laboratories are accredited by the National Voluntary

Laboratory Accreditation Program (NVLAP), which is administered by the National Institute of Standards and

Technology.

Polarized Light Microscopy (PLM)

The suspect materials were analyzed by trained microscopists using PLM techniques coupled with dispersion

staining in accordance with EPA Test Method Title 40 Code of Federal Regulations, Chapter I (1-1-87 edition), Part

763, Subpart F-APPENDIX A. This method identifies asbestos mineral fibers based on six optical characteristics:

morphology, birefringence, refractive index, extinction angle, sign of elongation and dispersion staining colors.

The laboratory analysis reports the specific type of asbestos identified (there are six asbestos minerals) and the

percentage of asbestos present.

Transmission Electron Microscopy (TEM)

Suspect non-friable organically bound materials, exhibiting negative results via PLM analysis, were analyzed by

trained microscopists by TEM using EPA 600 Method in accordance with ASTM E2356. Typical examples of this

material include, but are not limited to floor tile, mastic adhesives, sheet flooring (linoleum), roofing materials,

glazing, caulking, duct mastic and cove base mastic.

3.2 Assessment

The sampled materials were assessed based on condition (good, fair or poor) and potential for disturbance due to

the scheduled renovation/demolition. The sampled materials were also categorized based on the EPA’s National

Emission Standards for Hazardous Air Pollutants (NESHAP) regulation categories. Friable ACM is classified as an

ACM that can be crumbled to a powder by moderate hand pressure. Non-friable ACM is classified as either

Category I Non-friable ACM or Category II Non-friable ACM. Category I and Category II Non-friable ACM are

distinguished from each other by their fiber release potential when damaged. Generally, Category I Non-friable

ACM, which by definition includes intact ACM roofing materials, gaskets, packing, resilient floor coverings and

floor mastics, is less likely to become friable and release fibers in a damaged state. Category II Non-friable ACM

include all other non-friable ACM excluding Category I that have a high probability of being rendered friable

Page 7: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

December 27, 2018 4

during removal activities or demolition. All Friable ACM, Category I Non-friable ACM that has become friable,

Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or

Category II Non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or

reduced to powder by the forces expected to act on the material in the course of demolition or renovation

operations are considered to be a Regulated Asbestos-Containing Material (RACM).

3.3 Findings and Results

The EPA and SCDHEC define materials as asbestos containing when an asbestos content >1% is detected in a

representative sample.

No asbestos-containing materials were identified in the residential structure, or two storage shed structures.

In accordance with SCDHEC Regulation 61-86.1, TEM analysis was performed on one sample of each of the non-

friable, organically-bound (NOB) materials that displayed a result of no asbestos detected or less than 1%

asbestos via PLM analysis. NOBs consist of materials such as vinyl floor tiles, vinyl baseboards and mastics. Please

refer to Table 1 in Appendix II for more detail regarding which samples of NOB materials were submitted for TEM

analysis.

4.0 Assumptions and Limitations

This report is provided for the sole use of the Client. Use of this report by any other parties will be at such party’s

sole risk, and S&ME disclaims liability for any such use or reliance by third parties. The results presented in this

report are indicative of conditions only during the time of the sampling period and of the specific areas

referenced. Under no circumstances is this report to be used as a bidding document, or as a project design or

specification.

S&ME performed the services in accordance with generally accepted practices of reputable environmental

consultants undertaking similar studies at the same time and in the same geographical area. S&ME has

endeavored to meet this standard of care. No other warranty, expressed or implied, is intended or made with

respect to this report or S&ME’s services. Users of this report should consider the scope and limitations related to

these services when developing opinions as to risks associated with the site.

The possibility exists that suspect materials were undetected in inaccessible or concealed areas such as under

carpeting or multiple flooring layers, and inside pipe chases or wall voids. If additional suspect materials are

discovered during the planned destructive activities, bulk samples must be collected by an asbestos inspector and

analyzed for asbestos content.

5.0 Conclusions and Recommendations

No asbestos-containing materials were identified in the building. Therefore, no specific recommendations are

made at this time. If the structure remains unchanged from the condition observed during the performance of

this assessment, the report will remain valid for three years.

Page 8: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment Report

Residential Structure – 1530 West Bramlett Road

Greenville, South Carolina

S&ME Project No. 4226-18-003, Phase 47

December 27, 2018 5

This report should be provided to the contractor(s) to assist with compliance with applicable State and Federal

regulations. If additional suspect materials are discovered during renovation activities, bulk samples must be

collected and analyzed for asbestos content prior to continuation of work.

Page 9: 1530 W Bramlett Rd Asbestos Report - Greenville County

Appendices

Page 10: 1530 W Bramlett Rd Asbestos Report - Greenville County

Appendix I – Figures and Photographs

Page 11: 1530 W Bramlett Rd Asbestos Report - Greenville County

FIGURE NO.

CHECKED BY: SW 1530 W Bramlett Road1

DRAWN BY: TRW Greenville, South Carolina

SCALE: NTS Approximate Asbestos Sample Locations

DATE: 11/30/2018 Project Number : 4226-18-003 Phase 49

B2

C2

Kitchen

Structure #3

Structure #2

Bathroom

#2

Living RoomMaster Bedroom

Structure #1 (Main)

A1

B3, C3

F3

A2

G3

F2

Bedroom #1

Bathroom

#1

A3

D3

E3

D1

D2

B1

C1

E2E1

G2

G1F1

Page 12: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment

1530 W Bramlett Road

Greenville, South Carolina

S&ME Project # 4226-18-003 Phase 49

Taken by: Taylor Williams Date Taken: 11/30/2018

1

1 General view of the front of the main structure. 2 General view of the back of the main structure.

3 General view of the crawl space of the main structure. 4 General view of Structure #2.

Page 13: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment

1530 W Bramlett Road

Greenville, South Carolina

S&ME Project # 4226-18-003 Phase 49

Taken by: Taylor Williams Date Taken: 11/30/2018

2

5 General view of Structure #3.. 6 Sample A: 12-inch white peel & stick vinyl flooring.

No asbestos detected.

7 Sample B: White and blue vinyl sheet flooring (top layer).

No asbestos detected. 8 Sample C: Green and brown vinyl sheet flooring (bottom layer).

No asbestos detected.

Page 14: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment

1530 W Bramlett Road

Greenville, South Carolina

S&ME Project # 4226-18-003 Phase 49

Taken by: Taylor Williams Date Taken: 11/30/2018

3

9 Sample D: Drywall ceiling and textured material.

No asbestos detected. 10 Sample E: Rubber roof membrane.

No asbestos detected.

11 General interior view of Structure #2. 12 Sample F: Roof shingles with felt paper on roof of Structure #2.

No asbestos detected.

Page 15: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Assessment

1530 W Bramlett Road

Greenville, South Carolina

S&ME Project # 4226-18-003 Phase 49

Taken by: Taylor Williams Date Taken: 11/30/2018

4

13 General interior view of Structure #3. 14 Sample G: Roof shingles with felt paper on roof of Structure #3.

No asbestos detected.

No Photo No Photo

15 16

Page 16: 1530 W Bramlett Rd Asbestos Report - Greenville County

Appendix II – Table 1 – Summary of Asbestos Results

Page 17: 1530 W Bramlett Rd Asbestos Report - Greenville County

A1

A2

A3

(TEM)

B1

B2

B3

(TEM)

C1

C2

C3

(TEM)

D1

D2

D3

E1

E2

E3

(TEM)

F1

F2

F3

(TEM)

G1

G2

G3

(TEM)

1) Quantities listed above are estimates to be used for inspection purposes only.

2) Samples shown in bold are designated as asbestos-containing materials (ACMs).

3) Sampled by Taylor Williams, SCDHEC License No. 01602.

PD 200 SF

12-inch White Peel & Stick Vinyl

Flooring Hallway and Both Bathrooms

Vinyl Flooring - NAD

Mastic - NADNon-Friable Damaged PD 50 SF

White and Blue Vinyl Sheet

Flooring (top layer)Kitchen Vinyl Flooring - NAD Non-Friable Damaged

200 SFNon-Friable Good LPD

Friable Damaged PD 850 SF

200 SFLPDGoodNon-Friable

Non-Friable Good

NOTES:

Green and Brown Vinyl

Sheet Flooring (bottom layer)Kitchen Vinyl Flooring - NAD

Drywall Ceiling and

Textured Material Throughout

Drywall - NAD

Joint Compound - NAD

Roof Shingles with Felt PaperShingle - NAD

Felt Paper - NADRoof of Structure #2

Roof Shingles with Felt Paper Roof of Structure #3

Rubber Roof Membrane Roof NAD

Table 1

Asbestos Results Summary

Greenville, South Carolina

Estimated

Quantity

Sample

NumberAnalytical Results

S&ME Project No. 4226-18-003 Phase 49

Friable /

Non-Friable

Current

Condition

Potential for

Disturbance

1530 W Bramlett Rd

Sample Description Location

LPD 850 SF

Shingle - NAD

Felt Paper - NADNon-Friable Good LPD 125 SF

Page 18: 1530 W Bramlett Rd Asbestos Report - Greenville County

Table 1

Asbestos Results Summary

Greenville, South Carolina

Estimated

Quantity

Sample

NumberAnalytical Results

S&ME Project No. 4226-18-003 Phase 49

Friable /

Non-Friable

Current

Condition

Potential for

Disturbance

1530 W Bramlett Rd

Sample Description Location

SF - square feet

LF - linear feet

CF - cubic feet

NAD - No Asbestos Detected

Samples analyzed by PLM - Polarized Light Microscopy.

PACM - Presumed Asbestos Containing Material

Page 19: 1530 W Bramlett Rd Asbestos Report - Greenville County

Appendix III – Asbestos Laboratory Reports

Page 20: 1530 W Bramlett Rd Asbestos Report - Greenville County

December 4, 2018

S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

CLIENT PROJECT: 1530 W Bramlett Road, 4226-18-003 Phase 49CEI LAB CODE: A1816174

Dear Customer:

Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory onDecember 3, 2018. The samples were analyzed for asbestos using polarizing light microscopy(PLM) per the EPA 600 Method.

Sample results containing >1% asbestos are considered asbestos-containing materials(ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1%asbestos by weight as determined by visual estimation.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIHLaboratory Director

Kind Regards,

Page 21: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS ANALYTICAL REPORTBy: Polarized Light Microscopy

Prepared for

S&ME

CLIENT PROJECT:

LAB CODE:

TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORT DATE:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

1530 W Bramlett Road, 4226-18-003 Phase 49

A1816174

15

12/04/18

Page 22: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Report SummaryBy: POLARIZING LIGHT MICROSCOPY

PROJECT: 1530 W Bramlett Road, 4226-18-003Phase 49

LAB CODE: A1816174

Client ID Lab ID Color Sample DescriptionASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

A199250A Gray,Tan Vinyl Flooring None DetectedA1

A199250B Clear Mastic None Detected

A199251A Gray,Tan Vinyl Flooring None DetectedA2

A199251B Clear Mastic None Detected

A199252A Sample Submitted for TEMAnalysis

A3

A199252B Sample Submitted for TEMAnalysis

A199253 Tan Vinyl Flooring None DetectedB1

A199254 Tan Vinyl Flooring None DetectedB2

A199255 Sample Submitted for TEMAnalysis

B3

A199256 Green Vinyl Flooring None DetectedC1

Layer 1 A199257 Green Vinyl Flooring None DetectedC2

Layer 2 A199257 Brown Mastic None Detected

A199258 Sample Submitted for TEMAnalysis

C3

A199258 Sample Submitted for TEMAnalysis

Layer 1 A199259 White,Tan Drywall None DetectedD1

Layer 2 A199259 White Texture None Detected

Layer 1 A199260 White,Tan Drywall None DetectedD2

Layer 2 A199260 White Texture None Detected

Layer 1 A199261 White,Tan Drywall None DetectedD3

Layer 2 A199261 White Texture None Detected

A199262 Black Roof Membrane None DetectedE1

A199263 Black Roof Membrane None DetectedE2

A199264 Sample Submitted for TEMAnalysis

E3

Layer 1 A199265 Black Roof Shingle None DetectedF1

Layer 2 A199265 Black Felt Paper None Detected

Layer 1 A199266 Black Roof Shingle None DetectedF2

Layer 2 A199266 Black Felt Paper None Detected

Page 1 of 2

Page 23: 1530 W Bramlett Rd Asbestos Report - Greenville County

Asbestos Report SummaryBy: POLARIZING LIGHT MICROSCOPY

PROJECT: 1530 W Bramlett Road, 4226-18-003Phase 49

LAB CODE: A1816174

Client ID Lab ID Color Sample DescriptionASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 1 A199267 Sample Submitted for TEMAnalysis

F3

Layer 2 A199267 Sample Submitted for TEMAnalysis

Layer 1 A199268 Black Roof Shingle None DetectedG1

Layer 2 A199268 Black Felt Paper None Detected

Layer 1 A199269 Black Roof Shingle None DetectedG2

Layer 2 A199269 Black Felt Paper None Detected

Layer 1 A199270 Sample Submitted for TEMAnalysis

G3

Layer 2 A199270 Sample Submitted for TEMAnalysis

Page 2 of 2

Page 24: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY

Lab Code: A1816174Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18

Client IDLab ID

LabAttributes

LabDescription

ASBESTOS%

ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS

Non-Fibrous

Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

Project: 1530 W Bramlett Road, 4226-18-003 Phase 49

Fibrous

Gray,TanVinyl FlooringA1

A199250AHomogeneous

Non-fibrousBound

100% Vinyl None Detected

ClearMasticA199250B Homogeneous

Non-fibrousBound

100% Mastic None Detected

Gray,TanVinyl FlooringA2

A199251AHomogeneous

Non-fibrousBound

100% Vinyl None Detected

ClearMasticA199251B Homogeneous

Non-fibrousBound

100% Mastic None Detected

Sample Submitted forTEM Analysis

A3A199252A

Sample Submitted forTEM Analysis

A199252B

TanVinyl FlooringB1

A19925340%10%

Homogeneous

FibrousBound

50%CelluloseSynthetic Fiber

Vinyl None Detected

TanVinyl FlooringB2

A19925440%10%

Homogeneous

FibrousBound

50%CelluloseSynthetic Fiber

Vinyl None Detected

Sample Submitted forTEM Analysis

B3A199255

Page 1 of 6

Page 25: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY

Lab Code: A1816174Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18

Client IDLab ID

LabAttributes

LabDescription

ASBESTOS%

ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS

Non-Fibrous

Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

Project: 1530 W Bramlett Road, 4226-18-003 Phase 49

Fibrous

GreenVinyl FlooringC1

A19925625%25%

Homogeneous

FibrousBound

50%CelluloseSynthetic Fiber

Vinyl None Detected

GreenC2

A199257

25%25%

Homogeneous

FibrousBound

50%CelluloseSynthetic Fiber

Vinyl None DetectedLayer 1

Vinyl Flooring

BrownMastic

A199257Homogeneous

Non-fibrousBound

100% Mastic None DetectedLayer 2

Sample Submitted forTEM Analysis

C3A199258

Sample Submitted forTEM Analysis

A199258

White,TanD1

A199259

20%Heterogeneous

FibrousBound

80%Cellulose Gypsum None DetectedLayer 1

Drywall

WhiteTexture

A199259Heterogeneous

Non-fibrousBound

50%30%20%

BinderCalc CarbPaint

None DetectedLayer 2

White,TanD2

A199260

20%Heterogeneous

FibrousBound

80%Cellulose Gypsum None DetectedLayer 1

Drywall

Page 2 of 6

Page 26: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY

Lab Code: A1816174Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18

Client IDLab ID

LabAttributes

LabDescription

ASBESTOS%

ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS

Non-Fibrous

Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

Project: 1530 W Bramlett Road, 4226-18-003 Phase 49

Fibrous

WhiteTexture

A199260Heterogeneous

Non-fibrousBound

50%30%20%

BinderCalc CarbPaint

None DetectedLayer 2

White,TanD3

A199261

20%Heterogeneous

FibrousBound

80%Cellulose Gypsum None DetectedLayer 1

Drywall

WhiteTexture

A199261Heterogeneous

Non-fibrousBound

50%30%20%

BinderCalc CarbPaint

None DetectedLayer 2

BlackRoof MembraneE1

A199262Homogeneous

Non-fibrousBound

100% Vinyl None Detected

BlackRoof MembraneE2

A199263Homogeneous

Non-fibrousBound

100% Vinyl None Detected

Sample Submitted forTEM Analysis

E3A199264

BlackF1

A199265

60%Homogeneous

FibrousBound

35%5%

Fiberglass TarGravel

None DetectedLayer 1

Roof Shingle

BlackFelt Paper

A19926570%Homogeneous

FibrousBound

30%Cellulose Tar None DetectedLayer 2

Page 3 of 6

Page 27: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY

Lab Code: A1816174Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18

Client IDLab ID

LabAttributes

LabDescription

ASBESTOS%

ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS

Non-Fibrous

Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

Project: 1530 W Bramlett Road, 4226-18-003 Phase 49

Fibrous

BlackF2

A199266

60%Homogeneous

FibrousBound

35%5%

Fiberglass TarGravel

None DetectedLayer 1

Roof Shingle

BlackFelt Paper

A19926670%Homogeneous

FibrousBound

30%Cellulose Tar None DetectedLayer 2

F3

A199267Layer 1

Sample Submitted forTEM Analysis

Sample Submitted forTEM AnalysisA199267

Layer 2

BlackG1

A199268

60%Homogeneous

FibrousBound

35%5%

Fiberglass TarGravel

None DetectedLayer 1

Roof Shingle

BlackFelt Paper

A19926870%Homogeneous

FibrousBound

30%Cellulose Tar None DetectedLayer 2

BlackG2

A199269

60%Homogeneous

FibrousBound

35%5%

Fiberglass TarGravel

None DetectedLayer 1

Roof Shingle

BlackFelt Paper

A19926970%Homogeneous

FibrousBound

30%Cellulose Tar None DetectedLayer 2

Page 4 of 6

Page 28: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY

Lab Code: A1816174Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18

Client IDLab ID

LabAttributes

LabDescription

ASBESTOS%

ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS

Non-Fibrous

Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

Project: 1530 W Bramlett Road, 4226-18-003 Phase 49

Fibrous

G3

A199270Layer 1

Sample Submitted forTEM Analysis

Sample Submitted forTEM AnalysisA199270

Layer 2

Page 5 of 6

Page 29: 1530 W Bramlett Rd Asbestos Report - Greenville County

LEGEND: Non-Anth = Non-Asbestiform AnthophylliteNon-Trem = Non-Asbestiform TremoliteCalc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORTING LIMIT: <1% by visual estimation

REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points

REGULATORY LIMIT: >1% by weight

Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such asvinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends thatall NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by TransmissionElectron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos isnot covered under NVLAP accreditation. Estimated measurement of uncertainty is available onrequest.

This report relates only to the samples tested or analyzed and may not be reproduced, except in full,without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regardingthe accuracy of client submitted information in preparing and presenting analytical results.Interpretation of the analytical results is the sole responsibility of the client. Samples were received inacceptable condition unless otherwise noted. This report may not be used by the client to claimproduct endorsement by NVLAP or any other agency of the U.S. Government.

Information provided by customer includes customer sample ID, location, volume and area as well asdate and time of sampling.

Page 6 of 6

ANALYST: APPROVED BY:Tianbao Bai, Ph.D., CIHLaboratory Director

Megan Fisher

Page 30: 1530 W Bramlett Rd Asbestos Report - Greenville County
Page 31: 1530 W Bramlett Rd Asbestos Report - Greenville County
Page 32: 1530 W Bramlett Rd Asbestos Report - Greenville County

December 7, 2018

S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

CLIENT PROJECT: 1530 W Bramlett Road; 4226-18-003 Phase 49LAB CODE: T182891

Dear Customer:

Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory onDecember 4, 2018. The samples were analyzed for asbestos using transmission electronmicroscopy (TEM) per Chatfield Method.

Sample results containing > 1% asbestos are considered asbestos-containing materials(ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfieldmethod is <1% depending on the processed weight and constituents of the sample.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIHLaboratory Director

Kind Regards,

Page 33: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS ANALYTICAL REPORTBy: Transmission Electron Microscopy

Prepared for

S&ME

CLIENT PROJECT:

LAB CODE:

TEST METHOD: Bulk ChatfieldEPA 600 / R93 / 116

REPORT DATE:

1530 W Bramlett Road; 4226-18-003 Phase 49

T182891

12/07/18

Page 34: 1530 W Bramlett Rd Asbestos Report - Greenville County

ASBESTOS BULK ANALYSISBy: TRANSMISSION ELECTRON MICROSCOPY

Lab Code: T182891Date Received: 12-04-18Date Analyzed: 12-07-18Date Reported: 12-07-18

Client IDLab ID

MaterialDescription

TEM BULK CHATFIELD / EPA 600 / R93 / 116

Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607

Project: 1530 W Bramlett Road; 4226-18-003 Phase 49

SampleWeight

(g)

OrganicMaterial

%

Acid SolubleMaterial

%

Acid InsolubleMaterial

%Asbestos

%

T88568A3 Vinyl Flooring 0.679 31.4 63.2 5.4 None

Detected

T88569A3 Mastic 0.134 95.5 3 1.5 None

Detected

T88570B3 Vinyl Flooring 0.225 75.6 14.2 10.2 None

Detected

T88571C3 Vinyl Flooring 0.25 98 1.2 .8 None

Detected

T88572C3 Mastic 0.048 75 14.6 10.4 None

Detected

T88573E3 Roof Membrane 0.223 62.8 7.2 30 None

Detected

T88574F3 Roof Shingle 0.507 21.9 43.4 34.7 None

Detected

T88575F3 Felt Paper 0.83 97.5 1 1.5 None

Detected

T88576G3 Roof Shingle 0.397 31.7 47.4 20.9 None

Detected

T88577G3 Felt Paper 01.255 87.2 2.5 10.3 None

Detected

Page 1 of 2

Page 35: 1530 W Bramlett Rd Asbestos Report - Greenville County

LEGEND: None

METHOD: CHATFIELD & EPA/600/R-93/116

LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)

REGULATORY LIMIT: >1% by weight

This report relates only to the samples tested or analyzed and may not be reproduced, except in full,without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regardingthe accuracy of client submitted information in preparing and presenting analytical results.Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement ofuncertainty is available on request. Samples were received in acceptable condition unless otherwisenoted.

Information provided by customer includes customer sample ID, location, volume and area as well asdate and time of sampling.

Page 2 of 2

ANALYST: APPROVED BY:Tianbao Bai, Ph.D., CIHLaboratory Director

Jennifer Turner

Page 36: 1530 W Bramlett Rd Asbestos Report - Greenville County
Page 37: 1530 W Bramlett Rd Asbestos Report - Greenville County
Page 38: 1530 W Bramlett Rd Asbestos Report - Greenville County

Appendix IV – Copy of Inspector’s License

Page 39: 1530 W Bramlett Rd Asbestos Report - Greenville County

S&ME, Inc. | 48 Brookfield Oaks Drive, Suite F | Greenville, SC 29607 | p 864.297-9944 | www.smeinc.com

South Carolina Department

of

Health and Environmental Control

Asbestos License

Taylor R Williams