Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
1
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018FEATURES
Features• 1600 Wall SystemTM3 is an inside / outside glazed captured curtain wall• 1600 Wall SystemTM3 has a 2-1/2" (63.5) sight line• Standard 6" (152.4) or 7-1/2" (190.5) depth systems are compatible with SystemTM1 and
SystemTM2• Inside glazed verticals utilize the IsoStrutTM thermal barrier to provide superior structural and
thermal performance• Integral vertical exterior cover and thermal barrier reduce installed cost• Horizontals utilize a thermal separator and pressure plate to allow for glazing or re-glazing
from the exterior• Standard infill options are 1/8" (3.2), 1/4" (6.4) and 1" (25.4)• Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer• Concealed fastener joinery creates smooth, monolithic appearance• Shear block fabrication method• Standard 90 and 135 degree inside and outside corners• Offers integrated entrance framing systems• Peroxide-cure high performance EPDM silicone compatible glazing materials for long-lasting
seals• Two color option• PermanodicTM anodized finishes in seven choices• Painted finishes in standard and custom choices
Optional Features• Steel reinforcing• Integrates with standard Kawneer windows and GLASSventTM windows for curtain wall • 1600 PowerWallTM solar photovoltaic (PV) infill in lieu of glass
Product Applications• Ideal for low-rise to high-rise curtain wall applications where inside glazing and high
performance is desired
For specific product applications,Consult your Kawneer representative.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
2
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018BLANK PAGE
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
3
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018INDEX
PICTORIAL VIEW .................................................................................... 5TYPICAL 1/4 SIZE DETAILS ................................................................ 6-7ENTRANCE ADAPTERS ......................................................................... 8CORNERS ................................................................................................ 8 ANCHORING ........................................................................................... 9WIND LOAD CHARTS ...................................................................... 10-14DEADLOAD CHARTS ...................................................................... 15-17THERMAL CHARTS ......................................................................... 18-22
Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI ) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
4
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018BLANK PAGE
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
5
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018PICTORIAL VIEW
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
6
EC 97911-182
1
11 913A 13
7
7A
12 10
8
1
2
3
4
5
6
2
3
4
5
13
6
1113A
9
7 87A
12 10
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018TYPICAL 1/4 SIZE DETAILS
NOTE:6" SYSTEM SHOWN, 7-1/2" SIMILAR. INSIDE GLAZED IsoStrutTM VERTICALS SHOWN.
OPTIONALHORIZONTAL
ALTERNATEJAMB
ELEVATION IS NUMBER KEYED TO DETAILS
Additional information and CAD details are available at www.kawneer.com
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulated Glass Unit Manufacturers.
Structural Silicone Sealant (by Others)*
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
7
EC 97911-182
1
11 913
7
7A
12 10
8
1
2
3
4
5
6
2
3
4
5
13
6
11
14
9
7 87A
12
14
10
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018
NOTES:6" SYSTEM SHOWN, 7-1/2" SIMILAR. APPLIED PRESSURE PLATE OPTION SHOWN.
OPTIONALHORIZONTAL
TYPICAL1/4 SIZE DETAILS
ELEVATION IS NUMBER KEYED TO DETAILS
Additional information and CAD details are available at www.kawneer.com
* INSTALLER NOTE: Installer is responsible for all required compatibility review and approvals with the Structural Silicone Manufacturer and the Insulated Glass Unit Manufacturers.
Structural Silicone Sealant (by Others)*
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
8
EC 97911-182
2
1 1
2
3
7/8"(22.2)
1 3
2
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018ENTRANCE ADAPTERS / CORNERS
CORNERS
ENTRANCE ADAPTERS
NOTE:OFFSET PIVOT/BUTT HUNG ENTRANCE SHOWN.ALSO AVAILABLE FOR CENTER HUNG
INSIDE 90° CORNEROUTSIDE 90° CORNER
OUTSIDE 135° CORNER INSIDE 135° CORNER
ELEVATION IS NUMBER KEYED TO DETAILS
Additional information and CAD details are available at www.kawneer.com
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
9
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018ANCHORING
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
10
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018
DEADLOAD CHARTSHorizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown.
WIND LOAD CHARTSMullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104 MPa), STEEL 30,000 psi (207 MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information.
WIND LOAD / DEAD LOAD CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
11
EC 97911-182
1 21.5
1.5
2
2.5
3
3.5
4
4
5
6
7
8
9
10
11
12
13
14
15
1 2 3 4 5 6 7 8
E
DC
B
A
.5
1 21.5
1.5
2
2.5
3
3.5
4
4
5
6
7
8
9
10
11
12
13
14
15
1 2 3 4 5 6 7 8
E
D
C
B
A
.5
163200
163201
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018WIND LOAD CHARTS
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
Allowable Stress Design Load
LRFD Ultimate Design Load
A = 20 PSF (960) 33 PSF (1580)B = 30 PSF (1440) 50 PSF (2400)C = 40 PSF (1920) 67 PSF (3200)D = 50 PSF (2400) 83 PSF (4000)E = 60 PSF (2880) 100 PSF (4790)
MU
LLIO
N H
EIG
HT
MU
LLIO
N H
EIG
HT
SINGLE SPAN
SINGLE SPAN
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
12
EC 97911-182
1 21.5
1.5
2
2.5
3
3.5
4
4
5
6
7
8
9
10
11
12
13
14
15
1 2 3 4 5 6 7 8
EDC
B
A
.5
1 21.5
1.5
2
2.5
3
3.5
4
4
5
6
7
8
9
10
11
12
13
14
15
1 2 3 4 5 6 7 8
E
D
C
B
A
.5
163204
163205
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018WIND LOAD CHARTS
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
Allowable Stress Design Load
LRFD Ultimate Design Load
A = 20 PSF (960) 33 PSF (1580)B = 30 PSF (1440) 50 PSF (2400)C = 40 PSF (1920) 67 PSF (3200)D = 50 PSF (2400) 83 PSF (4000)E = 60 PSF (2880) 100 PSF (4790)
MU
LLIO
N H
EIG
HT
MU
LLIO
N H
EIG
HT
SINGLE SPAN
SINGLE SPAN
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
13
EC 97911-182
1 21.5
1.5
2
2.5
3
3.5
4
4
5
6
7
8
9
10
11
12
13
14
15
1 2 3 4 5 6 7 8
ED
C
B
A
.5
1 21.5
1.5
2
2.5
3
3.5
4
4
5
6
7
8
9
10
11
12
13
14
15
1 2 3 4 5 6 7 8
E
D
C
B
A
.5
163208
163209
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018WIND LOAD CHARTS
METERS
MULLION CENTERS IN FEET
ME
TER
S
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
MU
LLIO
N H
EIG
HT
IN F
EE
T
Allowable Stress Design Load
LRFD Ultimate Design Load
A = 20 PSF (960) 33 PSF (1580)B = 30 PSF (1440) 50 PSF (2400)C = 40 PSF (1920) 67 PSF (3200)D = 50 PSF (2400) 83 PSF (4000)E = 60 PSF (2880) 100 PSF (4790)
MU
LLIO
N H
EIG
HT
MU
LLIO
N H
EIG
HT
SINGLE SPAN
SINGLE SPAN
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
14
EC 97911-182
163038
163039
1 21.5
1
1.5
2
2.2
3
3.3
0
1
2
3
4
5
6
7
8
9
10
18
0 2 3 4 5 6 7 8
.5
1
11
12
13
14
15
16
17
4
4.4
5
.5
ED
C
B
A
1 21.5
1
1.5
2
2.2
3
3.3
0
1
2
3
4
5
6
7
8
9
10
18
0 2 3 4 5 6 7 8
.5
1
11
12
13
14
15
16
17
4
4.4
5
.5
E
D
C
B
A
E
D
C
B
A
1 21.5
4
4.5
5
5.5
6
6.5
12
13
14
15
16
17
18
19
20
21
22
30
0 2 3 4 5 6 7 8
.5
1
23
24
25
26
27
28
29
7
7.5
8
8.5
9
E
D
C
B
A
1 21.5
4
4.5
5
5.5
6
6.5
12
13
14
15
16
17
18
19
20
21
22
30
0 2 3 4 5 6 7 8
.5
1
23
24
25
26
27
28
29
7
7.5
8
8.5
9
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
MULLION CENTERS IN FEET
MU
LLIO
N H
EIG
HT
IN F
EE
T
ME
TER
S
WIND LOAD CHARTS
Allowable Stress Design Load
LRFD Ultimate Design Load
A = 20 PSF (960) 33 PSF (1580)B = 30 PSF (1440) 50 PSF (2400)C = 40 PSF (1920) 67 PSF (3200)D = 50 PSF (2400) 83 PSF (4000)E = 60 PSF (2880) 100 PSF (4790)
MU
LLIO
N H
EIG
HT
MU
LLIO
N H
EIG
HT
EQU
AL
EQU
AL
MU
LLIO
N H
EIG
HT
MU
LLIO
N H
EIG
HT
EQU
AL
EQU
AL
SINGLE SPAN
SINGLE SPAN TWIN SPAN
TWIN SPAN
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
15
EC 97911-182
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
163004
163005
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018DEADLOAD CHARTS
A = 1/4 POINT LOADINGB = 1/8 POINT LOADING
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEETG
LAS
S H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
1/4" GLASS 1" GLASS
1/4" GLASS 1" GLASS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
16
EC 97911-182
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
B
A
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
163010163004
163010163005
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018DEADLOAD CHARTS
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
A = 1/4 POINT LOADINGB = 1/8 POINT LOADING
1/4" GLASS 1" GLASS
1/4" GLASS 1" GLASS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
17
EC 97911-182
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
.5 1 1.5 2
12
13
11
10
9
8
7
6
5
4
3
1
0
2
0 1 7 82 43 65
3.5
3
2.5
2
1.5
1
0.5
0
A
B
163025
163026
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018DEADLOAD CHARTS
A = 1/4 POINT LOADINGB = 1/8 POINT LOADING
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
METERS
SPAN IN FEETG
LAS
S H
EIG
HT
IN F
EE
T
ME
TER
S
METERS
SPAN IN FEET
GLA
SS
HE
IGH
T IN
FE
ET
ME
TER
S
1/4" GLASS 1" GLASS
1/4" GLASS 1" GLASS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
18
EC 97911-182
2-1/2" Typ.3'
-0"
4'-0
"8'
-0"
6'-0
"9'
-0"
31'-3
"
5'-0"
2-1/
2"Ty
p.
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018THERMAL CHARTS
Generic Project Specific U-factor Example Calculation(Percent of Glass will vary on specific products depending on sitelines)
(Based on single bay of Curtain Wall/Window Wall)
Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F)
Vision Area = 5(9 + 8 + 4) = 105.0 ft2
Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2
Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93%Spandrel Area
Example Spandrel R-value = 15 (ft2 · h · °F)/Btu
Spandrel Area = 5(6 + 3) = 45.0 ft2
Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2
Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (45.0 ÷ 49.6)100 = 91%
SPANDREL
VISION
VISION
SPANDREL
VISION
D.L.O.
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
D.L
.O.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
19
EC 97911-182
0.53
93%
0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20
0.70
0.80
0.60
0.50
0.40
0.30
0.2095 90 85 80 75 70
0.21
91%
2.00
3.00
4.00
5.00
11.0015.0019.0030.00
0.60
0.50
0.40
0.30
0.20
95 90 85 80 75 700.10
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018THERMAL CHARTS
Vision Area Chart
Spandrel Area Chart
System U-factor vs Percent of Vision Area
COGU-factor
Spandrel R-value
System U-factor vs Percent of Spandrel Area
Vision Area / Total Area (%)
Spandrel Area / Total Area (%)
Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F)
Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F)
Btu
h·
ft 2 ·°
F Sy
stem
U-fa
ctor
Btu
h·
ft 2 ·°
F Sy
stem
U-fa
ctor
EXAMPLE
(NOT FOR DESIGN)
EXAMPLE
(NOT FOR DESIGN)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
20
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018
0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20
0.70
0.80
0.60
0.50
0.40
0.30
0.2095 90 85 80 75 70
0.75
0.65
0.55
0.45
0.35
0.25
(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)
2.00
3.00
4.00
5.00
11.00
15.00
19.0030.00
(0.35)
(0.53)
(0.70)
(0.88)
(1.94)
(2.64)
(3.34)(5.28)
(4.00)
(4.50)
(3.50)
(3.00)
(2.50)
(1.50)
(2.00)
0.70
0.60
0.50
0.40
0.30
0.20
95 90 85 80 75 70
0.65
0.55
0.45
0.35
0.25
(4.00)
(3.50)
(3.00)
(2.50)
(1.50)
(2.00)
0.15
0.05
0.10 (1.50)
(2.00)
Spandrel R-Value
System U-Factors for Spandrel Glass
Spandrel Area / Total Area (%)
System U-Factor for Vision Glass
COG U-factor
Vision Area / Total Area (%)
Syst
em U
-Fac
tor (
Btu
/h·ft
2 ·°F)
Syst
em U
-Fac
tor (
W/m
2 ·°C
)
Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507.
Syst
em U
-Fac
tor (
Btu
/h·ft
2 ·°F)
Syst
em U
-Fac
tor (
W/m
2 ·°C
)
THERMAL CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
21
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018
0.90
0.85
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
75
0.90
0.85
7085 8095 90
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.90
0.85
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
75
0.90
0.85
7085 8095 90
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COGSHGC
COG VT
System Visible Transmittance (VT) vs Percent of Vision Area
Vision Area / Total Area (%)
Vision Ares / Total Area (%)
Syst
em S
HG
C
Charts are generated per AAMA 507.
Charts are generated per AAMA 507.
Syst
em V
T
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y, K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
,
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent,
© K
awne
er C
ompa
ny, I
nc,,
2014
kawneer.com
22
EC 97911-182
1600 Wall SystemTM3 Curtain Wall
ADMD030EN
NOVEMBER, 2018
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.560.46 0.550.44 0.530.42 0.510.40 0.490.38 0.480.36 0.460.34 0.440.32 0.430.30 0.410.28 0.390.26 0.370.24 0.360.22 0.340.20 0.32
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.690.70 0.650.65 0.600.60 0.560.55 0.510.50 0.470.45 0.430.40 0.380.35 0.340.30 0.290.25 0.250.20 0.200.15 0.160.10 0.110.05 0.07
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.90 0.810.85 0.760.80 0.720.75 0.670.70 0.630.65 0.580.60 0.540.55 0.490.50 0.450.45 0.400.40 0.360.35 0.310.30 0.270.25 0.220.20 0.18
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2,000 mm wide by 2,000 mm high (78-3/4" by 78-3/4").