01L 17.02.10 AS BUILT JGL SAK GKri B 27.01.10 Issued for Acceptance JGL SAK GKri A 03.12.09 Issued for Acceptance FrLe KjAB GKri Rev./ status Date Reason for issue Author Contr. Disc Approved Contractor Approved Hydro Approved Access Keywords Replace Replaced by Issued by Package no. U Unclassified H Internal (Unit) F Confidential SF Strictly confidential Retention EEx p Manual 50217 Responsible Purchase order no. Frode Lervik PO 5451115 Area System Supplier ref. C14 23 1235.000-Z-003 Tag. no 0 To be destroyed after handling 3 Retention 3 months 2 Retention 2 years 5 Retention > 5 years P Retention project period P02 Retention project period plus 2 years P05 Retention project period plus 5 years P10 Retention project period plus 10 years E Return to basic organisation I Until reissued Supplier EE-23-0001 Document title Client TECHICAL MANUAL FOR EEx p SYSTEM HYDRO V&M Cover Pages 27 Attachment ACCEPTANCE CODES : ID. NO. 1: Accepted 2: Accepted with comments incorporated Document no. 3: Not accepted. Revise and resubmit Project and installation Orginator Discip.+Doc. type Package no. Sequence no. Rev./ Status 4: For information only 17-1B AOP E04 50217 0001 01L

17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

  • Upload
    phamdat

  • View
    236

  • Download
    5

Embed Size (px)

Citation preview

Page 1: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

01L 17.02.10 AS BUILT JGL SAK GKri B 27.01.10 Issued for Acceptance JGL SAK GKri A 03.12.09 Issued for Acceptance FrLe KjAB GKri Rev./ status

Date Reason for issue Author Contr. Disc Approved

Contractor Approved

Hydro Approved

Access Keywords Replace Replaced by Issued by Package no.

U Unclassified

H Internal (Unit)

F Confidential

SF Strictly confidential

Retention

EEx p Manual

50217

Responsible Purchase order no. Frode Lervik PO 5451115

Area System Supplier ref. C14 23 1235.000-Z-003

Tag. no

0 To be destroyed after handling 3 Retention 3 months 2 Retention 2 years 5 Retention > 5 years P Retention project period P02 Retention project period plus 2

years P05 Retention project period plus 5

years P10 Retention project period plus 10

years E Return to basic organisation I Until reissued

Supplier

EE-23-0001

Document title

Client

TECHICAL MANUAL FOR EEx p SYSTEM

HYDRO V&M

Cover Pages

27

Attachment

ACCEPTANCE CODES: ID. NO.

1: Accepted 2: Accepted with

comments incorporated Document no.

3: Not accepted. Revise and resubmit

Project and installation

Orginator Discip.+Doc. type

Package no. Sequence no. Rev./ Status

4: For information only 17-1B AOP E04 50217 0001 01L

Page 2: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

An der Hartbrücke 8 D-64625 Bensheim Tel.: 06251/63736 FAX: 06251/63729

sheet no. of sheets

STANDARD 1 25 title

TECHNICAL DOCUMENTATION EEx p SYSTEM F-361.C4

date of change revision originator format file

03.04.2006 Rev. 3.1 A4 F-361c4se.doc

rev. originator: release: 3.0

originate (date / sign) checked: (date / sign) release: (date / sign)

15.07.2003

07.04.2006 / QBS

Bachmann

EEEExx pp ssyysstteemm ffoorr mmoottoorr ooppeerraattiioonn iinn EExx--aarreeaass

Technical documentation

Page 3: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 2

Änd./

Mod.

15.07.2003 page 2 of 25

Description of EEx p system F-361.C4 The EEx p pressurization system F-361.C4 serves to create and maintain an overpressure in an EEx p motor enclosure to prevent the ingress of the ambient(potentially explosive) atmosphere, according to EN 60079-2 / EN 50016. In addition a compensation for leakage losses is realized in a unique redundancy combination with a mechanical and an electronic controlled proportional valve. Motors with kind of Ex-protection EEx p can operate in combination with the EEx p system F-361.F4 in Ex areas 1 and 2 (according to DIN EN 60079-14). Combined with an enclosure which is suitable for use with overpressure the Ex protection class EEx p IIC T4 according to EN 60079-2 / EN50016 can be obtained. Standard ambient temperature for operation is -20 °C up to +55°C. Other temperature ranges are available on request.

Before commissioning please take note of the following points: 1. Clean the connected air pipe or tubing system of the installation plant to ensure

that the supplied air tube is free of dirt or small parts which will cause a malfunction of the purging system, if no air filter is used.

2. The internal volume of the motor enclosure must be purged with non-explosive compressed air, to reduce a possible explosive gas concentration to safety limits.

3. After purging the motor enclosure, an overpressure must be maintained inside the motor to prevent ambient air, which can contain explosive gas.

The overpressure inside the motor enclosure is continuously monitored.

If the pressure drops under the reference value an alarm signal is given and the motor has to be switched off automatically. The EEx p System F-361.C4 comprises the following components:

• control cabinet ST-200F/ST-200FM

consists of: main air valve for pressure supply, purge valve, proportional valve for operating pressure (leakage compensation), adjustment valves for purge- and leakage volume, measure points (to acquire leakage volume and the pressure inside the motor enclosure), indicator for purge pressure, EEx d junction box F900.041, EEx d box F-900.001, main switch, control unit F-351 (connected with terminals in junction box) for the signals "ready to start“, “motor not purged“, purging in progress", "purge sequence finished" and „motor shutdown“.

The control cabinet ST-200C/200CM monitors the air flow of the outlet valve and the pressure inside the motor enclosure. Simultaneous the control automatic works in accordance with EN 60079-2 / EN 50016 and ATEX 94/9. This monitoring system is a highly secure and redundancy controlling unit certified according to EN954-1 (security class Cat. 3).

Page 4: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 3

Änd./

Mod.

15.07.2003 page 3 of 25

• Outlet valve VA-100-3H

The outlet facility consists of a heavy duty case with built in pneumatic controlled valve and integrated spark arrestor and particle barrier. The outlet valve opens during the purging sequence to ensure the purging of the motor enclosure according to EN60079-2/EN50016 .The outlet valve itself can be mounted in any position. The valve closes completely if the purging sequence is finished.

• Test certificate The motor system is provided with a test certificate as shown in the annexure of this documentation.

Mounting example

1: control cabinet ST-200C/CM 2: outlet valve VA-100-3H 3: measure point motor inside pressure 4: pilot line to outlet valve 5 and 6: measure points air volume 7: measure line motor inside pressure 8: compressed air connector for supply 9: compressed air connector to motor 10: motor enclosure

EEx p Motor

2

10

1

89

657

P A B

3

4

Page 5: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 4

Änd./

Mod.

15.07.2003 page 4 of 25

Dimensions of ST-200C

600

370

cable plate

grill panel

p min A Bp

50

100170

3060

0

800

640

earthing point M8

90

85130+5-5

85

pressure air outlet to motor

pressure air inlet

If not written down the tolerance is ± 2 mm. Dimensions of ST-200CM

If not written down the tolerance is ± 2 mm.

600

370

p minBAp

50

100170

30

600

800

640

90

85 130+5-5

85

pressure air inletpressure air outlet to motor

cable plateearthing point M8

grill panel

Page 6: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 5

Änd./

Mod.

15.07.2003 page 5 of 25

Outlet valve VA-100-3H

450

4 x Ø 18 mmhole arrangement according to DIN 2527NW 100 PN 16

100.

0200.

0

50.0

PA B

300.0

300.

0

67.5°

Ø180.0

450.0

If not written down the tolerance is ± 2 mm. P&I diagram

control unit F-351

P

Minswitch

P

Maxswitch

P

Purgeswitch

adjustment valve"Leakage volume"

main valve pressure regulator

purge valve adjustment valve"Purge volume"

motor enclosure

outlet valve

control valve

measuring pointdifferential pressure

Page 7: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 6

Änd./

Mod.

15.07.2003 page 6 of 25

Internal view control cabinet ST-200C / ST-200CM

13

67

5

98

10

06

11

12

2

4

3

1

17

2

1

3

4

5

14

15

16

18

212019

13

10

9

11

120 6

PE 11L1 N 322 64 5 PE7

51 3 7 9 11

PE

-X2

62 4 8 10

5

62 4

1 3

8 10

7 9

12

PE12

11

17

14

15

16

2 4

5

3

1

18

19

-X1

F1K2 K3

8

76

5

51 3 7 9 11

PE

-X2

62 4 8 10

5

62 4

1 3

8 10

7 9

12

PE12

11

PE743 6511 22PE NL1

2

4

3

1

2021

-X1

F1K2 K3

1: control unit F-351 12: adjustment valve “leakage comp.” 2: control cabinet 13: pressure gauge 3: EEx d enclosure F-900.001 14: proportional valve 4: EEx d enclosure F-900.041 15: purge valve 5: name plate 16: adjustment valve „purge volume“ 6: cable plate 17: test conn. “pilot pressure outlet valve” 7: test conn. „diff. pressure“ 18: main switch 8: air outlet to motor 19: conn. “pilot pressure outlet valve” 9: main air valve 20: conn. “diff.pressure” 10: grill panel 21: conn. “motor inside pressure” 11: pressure reducer

Page 8: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 7

Änd./

Mod.

15.07.2003 page 7 of 25

Technical data

1: Control unit F-351 Ex-protection class: II 2 G EEx e m ia [p] IIC T4 Protection class: IP 65 Temperature range: -30°C ... +60°C

Certified by: TÜV02 ATEX 1801 Security class: AK4, acc. to EN 954-1, cat. 3 Min flow volume: 0,1 – 99 Nl/s (setting: 10 Nl/s) Pressure switch „Min“: 0,8 – 25 mbar (setting 0,8 mbar) Pressure switch „Max“: 10 - 25 mbar (setting 15,0 mbar)

2: Control cabinet Type: ST-200C/CM Material: sheet steel, 2 mm

Colour: RAL 7032 Protection class: IP 23 (IP 55 on request) (Other materials or colours on request !) 3: Control- and junction box F-900.001 Ex-protection class: II 2 GD EEx d IIC T6 Protection class: IP 66 Temperature range: -20°C ... +55°C

Certified by: CESI 01 ATEX 036 Bore holes: ½“ NPT

EEx d cable glands Type: FL 1 Diameter: I1B (ELB), I1B for client Ex-protection class: EEx d IIC Protection class: IP 66 Temperature range: -20°C ... +80°C

Certified by: CESI 00 ATEX 052 4: Control- and junction box F-900.041 Ex-protection class: II 2 GD EEx d IIC T6 Protection class: IP 66 Temperature range: -20°C ... +55°C

Certified by: CESI 01 ATEX 036 Bore holes: ½“ NPT

EEx d cable glands Type: FL 1 Diameter: F1B (ELB), I1B for client Ex-protection class: EEx d IIC Protection class: IP 66 Temperature range: -20°C ... +80°C

Certified by: CESI 00 ATEX 052 5: name plate Identification of the system

Page 9: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 8

Änd./

Mod.

15.07.2003 page 8 of 25

6: Cable plate W x H x D: 160 x 120 x 10 mm Cut out in cabinet: 80 x 60 mm 7: Test connector

Differential pressure (Dim. for air volume) Connector: quick disconnect coupling DN 5 8: Air connector to motor: Rp 1“, inside screwed flanges on inquiry 9: main air valve: Rp1 ½”, inside screwed flanges on inquiry 10: Grill panel for air compensation 11: Pressure regulator Inlet pressure: max. 25 bar Outlet pressure: 0 – 6 bar 12: Adjustment valve „Leakage volume“ Adjustment range with prop.valve : max. 90 Nm³/h, at 3 bar pre- pressure 13: Pressure gauge Indication range: 0 – 6 bar 14: Control valve „Operating pressure“ Proportional valve (coil type 72): Tamb up to + 40 °C Proportional valve (coil type 73): Tamb up to + 55 °C Ex-protection class: II 2 G EEx m II T4

Certified by: PTB 00 ATEX 2202 X Operating range: variable Nm³/h

15: Purge valve Ex-protection class: II 2 G EEx em II T4 Temperature range: -30°C ... +60°C

Certified by: PTB No. 00 ATEX 2129 X Operating range: max. 450 Nm³/h 16: Adjustment valve

Purge volume Adjustment range if pre-pressure 3 bar: 0 – 450 Nm³/h

17: Test connector Pilot pressure outlet valve

Connector: quick disconnect coupling DN 5 Pilot pressure: ca. 1 bar

Page 10: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 9

Änd./

Mod.

15.07.2003 page 9 of 25

18: Main switch Ex-protection class: II 2 G EEx ed IIC T6 Protection class: max. IP66 Certified by: PTB 01 ATEX 1105

Temperature range: -20°C ... +50°C 19: Connector

Pilot line outlet valve Connection: male adapter union , tube 10 mm

20: Connector Differential pressure

Connection: male adapter union , tube 10 mm

21: Connector Motor inside pressure

Connection: male adapter union , tube 10 mm

Electrical data Power supply Purge Operate 230 VAC 150 mA 125 mA 115 VAC 300 mA 230 mA 24 VDC 1200 mA 750 mA

Temperature range F-361.C4 Tamb: -20°C ... +40°C, optional: -20°C ... +55°C, -40°C … +40°C, -40°C … +55°C For an operation below temperatures of – 20°C down to -40°C an Ex-heater (400 W) is additional mounted in the enclosure. Using the EEx p system with temperatures higher than + 40°C the proportional valve (Pos. 14) has to be interchanged with a proportional valve suitable for +60°C. The main switch (Pos. 18) has to be changed while the temperature is higher than + 50 °C. Weight Control cabinet ST-200C/CM: 88 kg Outlet valve VA-100-3H: 27 kg Minimum requirements for air pressure recommended pressure air volume: 450 m3/h / 3 bar particle size: 100 µm max water content: 90 % rel. humidity max medium temp. range: -10 °C … + 40 °C The maximum air flow can reach ca. 450 m³/h and produces during the purging sequence in the motor enclosure an overpressure of ca. 5 mbar. If the air quality is not guaranteed, special filters can be delivered on inquiry.

Page 11: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 10

Änd./

Mod.

15.07.2003 page 10 of 25

Basic functional description F-351 For a detailed description see manual F-350. Clear text LC display with choice of language. 3 lines with 12 characters each.

K1 Out PE

MENUE

ValvePE

OK / INFO button Switches the display over between measuring data and info menu. Confirms selected parameters or values.

Wheel Shuttle

Rotary switch, screwdriver-activated. Switches over between different parametrizing menus, submenus or selectable data.

CLEAR TEXT

DISPLAY–3X12

CHARACTERS

Page 12: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 11

Änd./

Mod.

15.07.2003 page 11 of 25

Menue

Lang

uage

?

Ent

erpu

rge

time

?

Sw

itchp

o int

min

pre

ssur

e

?

Sw

itchp

oint

o ver

pres

sure

?

Switc

hpoi

ntp u

rge

star

t

?

OK

OK

OK

OK

OK

E

nter

purg

e tim

e 0

0:1 0

min

Sw

itchp

oint

p urg

e st

art

xx.x

x m

b ar

0.0

5/ s

tep

1 m

bar/

s

tep

OK

1 m

bar/

s

tep

0.0

5/ s

tep

1 m

bar/

s

tep

0.0

5/ s

tep

OK

Par

amet

er ra

nge:

0

,8 -

25 m

bar

pres

et p

aram

eter

: 0,8

C

onfir

mm

in p

ress

ure

xx.

xx m

b ar

OK

OK

OK

C

onfir

mov

erpr

essu

re x

x.xx

mba

r

OK

pres

et p

aram

eter

: 25,

0

Par

amet

er ra

nge:

0

,8 -

25 m

bar

C

onfir

msw

p.pu

rgin

gxx

.xx

mba

r

OK

pres

et p

aram

eter

: 0,5

OK

Par

amet

er ra

nge:

0

,8 -

25 m

bar

upd

ate d

flow

(yy.

yy m

bar)

stor

ed a

s

purg

e st

art p

aram

eter

(x

x.xx

mba

r) s

et p

oint

= fe

e dba

ck v

alue

C

onfir

mS

wp.

pur

g ing

yy.

y y m

bar

OK

Dis

play

cont

ras t

####

____

OK

pres

et p

aram

eter

: 5

Par

amet

er ra

nge:

1

- 8

OK

OK

OK

Func

tion

of re

lay

K1 X

XXXX

Inpu

t dat

a- I

sola

tion

Pre

ssur

ere

gula

t ion

XX

XXX

OK

Par

amet

er ra

nge:

00:1

0 ...

99:

50 m

in

OK

pre s

et p

aram

eter

00:

10 m

in

OK

Con

firm

purg

e tim

e x

x.xx

mi n

Eng

l ish

Fran

cais

OK

OK

OK

Dis

play

cont

rast

?

Func

tion

of r

elay

K1

?

Pre

ssur

e re

gula

tion

?

- Sys

tem

Fau

lt- F

ault

1 m

in- F

ault

flash

- Pre

-al.

MIN

- Pre

-al.

MAX

- Pur

ging

- Byp

ass

pres

et p

aram

eter

: Pur

ging

OK

- Tw

o-po

sitio

n- p

ulse

d- p

ropo

rtion

al

pres

et p

aram

e ter

: pul

sed

Inpu

t dat

a

Sw

itchp

oint

min

pre

ssur

e x

x.xx

mba

r

Sw

itchp

oint

o ver

pres

sure

xx.

xx m

bar

Swp

purg

ing

xx.

xx m

bar

yy.

yy m

b ar

OK

Func

tion

bypa

ss

?

En

ter

Pas

swor

d

5112

OK

F

unct

ion

B

ypas

s<O

N>

/ OFF

OK

OK

F

unct

ion

B

ypas

s O

N /

<OFF

>

Qui

tB y

pass

men

ue

YE

S / N

O

OK

OK

(set

poi

nt)

(feed

back

val

ue)

pres

s fo

r 3 s

ec

12

34

56

78

9

Men

u is

act

ivat

ed, w

hen

Whe

el S

h uttl

e is

t urn

edA

ll m

enu s

are

clo

sed,

if n

o in

puts

are

mad

e fo

r mor

e th

an 1

0 s e

cond

s !

Sta

ndby

/op

erat

e m

odus

durin

g pu

rgin

g se

quen

ce a

ndp

>

switc

hpoi

nt p

(in c

ompi

latio

n)

MEN

U

Ger

man

Qui

tB y

pass

men

ue

YE

S / N

O

OK

Bac

k to

fact

ory

setti

ngs

(pre

sets

) :

- sw

itch

off p

ower

sup

ply

- ke e

p

pr

esse

dO

K

- sw

itch

on p

ower

sup

ply

- wai

t fo r

mes

sage

"LO

AD

ING

mot

or-p

urge

set

tings

"

- tur

n

to

6 o

'clo

ck

encl

osu r

em

in

++

OK

OK

+

Page 13: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 12

Änd./

Mod.

15.07.2003 page 12 of 25

Structure and Function

In conjunction with an enclosure (motor enclosure, junction box), the EEx-p system F-361.C4 provides a pressurized motor that is in compliance with EN 60079-2 / EN 50016. For this purpose, it has all the facilities and sensors needed to monitor the necessary purging phase and then to monitor and maintain an overpressure within the EEx-p enclosure (motor cabinet).

1 Structure

The controlling system consists mainly of two components which must be installed separately:

• controlling cabinet ST-200C/CM, with built-in piping ,valves, electronic and • the outlet valve VA-100-3H.

The controller F-351 itself monitors and regulates the overpressure in the enclosure, while the digital/proportional valves doses the air quantity needed to achieve the pressurized apparatus.

2 General Functional Description

After a functional test and start-up, the controller F-351 in the control cabinet ST-200C/CM monitors the flowrate of the compressed air or inert gas during the initial purging process, and then monitors and regulates the internal pressure of the EEx-p enclosure with regard to the surrounding atmosphere during normal operation.

Display In three lines of 12 characters each, the digital display shows the enclosure’s internal pressure during normal operation, and the remaining purging time in minutes and seconds during the initial purging process. During normal operation, you can call up further information by pressing the button "OK / Info". Faults which are detected during the self-check are shown here with a number. OK-button The button on the left side (“OK / INFO”) is used in normal operation to call up the stored parameters “Enclosure Pressure”, “Purging Time”, “Function of Relay 3”, “Function of Relay 4”, “Switchpoint of Purge Start”, “Switchpoint of Minimum Pressure”, “Switchpoint of Overpressure” and “Regulation”. During the parametrization, this button is used to select and confirm the various parameters.

Page 14: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 13

Änd./

Mod.

15.07.2003 page 13 of 25

Rotary switch The right field (“Menu”) permits access to the Wheel Shuttle® with a tool (e.g. a screwdriver) for parametrizing the controller. With this Wheel Shuttle, you can start the parametrization and set the individual parameter values.

Screw terminal In the lower part of the cover (see page 1), the terminal assignment of the Controller is shown. Terminals 1 to 3 are inputs; they provide electrical power to the Controller. Terminals 4 to 19 are outputs, over which the monitoring unit drives its peripherals, e.g. the digital/proportional controller.

Immediately after the compressed air supply is opened and the main voltage is applied, the internal self-check of the controller begins automatically. Any fault occurring during the self-check sequence is indicated by An explanation of the fault numbers (XX) is given in the manual, section 3.5 “Faults and Troubleshooting”, Table 1: Faults detected during the self-check. If the self-check is carried out successfully, the initial purging of the enclosure commences, ending when at least five times the enclosure volume has been circulated. The purging process is indicated by the message in the display. All the time, the remaining purging time is counted down to 00 min and 00 seconds. After the end of the purging sequence, the Non-Ex units in the enclosure are switched on. The overpressure in the enclosure then constantly monitored for adherence to the setpoint value (factory setting: 2.0 mbar) and also for transgressing of the Min value (factory setting: 0.9 mbar) and exceeding of the Max value (factory setting: 20.0 mbar). Normal operation is indicated by the message in the display.

FAULT XX

REMAINING PURGE TIME: XX MIN XX SEC

ENCLOSURE PRESSURE: XX..XX MBAR

Page 15: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 14

Änd./

Mod.

15.07.2003 page 14 of 25

3 Behaviour of the controller during normal operation In normal operation, the controller F-351 in the control cabinet ST-200C/CM monitors and regulates the internal pressure of the EEx-p enclosure to the setpoint value in relation to the surrounding atmosphere. The limit values set in the factory are: MIN: 0.8 mbar and MAX: 15.0 mbar. At an increased level of internal enclosure pressure (over the limit value for Max) with regard to the surrounding atmosphere, the mechanical valve VA-100-3H opens automatically. This allows the excessive internal pressure to drop. The valve closes again when the internal enclosure pressure has again attained normal values (under the limit value for Max). Function procedure of the EEx p system After connecting the pressure supply and turn on the main switch (Pos.18) the purge valve (Pos.15), the proportional valve (Pos.14) and the outlet valve VA-100-3H are open. Through the adjustment valve (Pos.12) and in addition through the proportional valve and the parallel mounted manual valve (Pos. 9) the pressure air reaches the motor enclosure and flees through the outlet valve VA-100-3H. If the purge flow of the motor enclosure exceeds the adjusted minimum flow value, the purging sequence starts. The remaining purge time is displayed. If the air flow through the motor during the purging sequence drops below the pressetted value for minimum flow, the purging sequence stops. The required purging time depends on the setting of the purge volume (normally 10 times the free volume of the motor cabinet) and the presetted inlet pressure at the pressure regulator (7). After the purging sequence is finished: The power supply of the purge valve (Pos.15) is cut off with the relay K3 in the EEx d box. Thereby the outlet valve VA-100-3H and the purge valve closes. The pressure air now flows only through the manual valve "leakage losses" and the proportional valve in the motor enclosure. The required overpressure in the motor enclosure is now maintained by the proportional valve and the manual valve. Likewise due to compensation of leakage losses. At the terminals –X2 9 and 10 in the EEx d box the signal "ready to start" is given. The overpressure in the motor enclosure is monitored by the pressure switches "Min" and "Max" of the control unit. If the overpressure drops below the presetted value "Min", or exceeds the overpressure value "Max", then K2 and K3 in the EEx d box are switching and a signal is given to cut off the motor power. To prevent a false alarm, as a result of pressure oscillations through the motor housing during the purging sequence, terminals 9 and 10 have a drop-out time delay of approx. 5 sec.

Page 16: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 15

Änd./

Mod.

15.07.2003 page 15 of 25

EEx d junction and control box F-900.041 In the EEx d junction box are all needed functions for the potential free signals and terminals for power supply mounted. The power supply has to be connected

in this box. The EEx d box consists of: 2 x PE terminals type USLKG 5 11 x terminals type UK5N 2 x relays with 4 switchover contacts (K2, K3) 1 x fuse holder 7 x bore holes ½“ NPT 5 x EEx d cable glands type FL1 F1B (used by ELB) 1 x EEx d cable gland type FL1 I1B (used by ELB) 1 x EEx d cable gland type FL1 I1B (cable ø = 10,5 – 12 mm) for power supply (customer) Cable glands for other diameters or armoured cables on request. Terminal block

-X1

NPE L1 11 22

F1

53

64

5

6

3

47 PEPE

-X1

4 6

3 5

PE L1 N 1 1 2 24

3

6

5

F1

PE7 PE

Page 17: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 16

Änd./

Mod.

15.07.2003 page 16 of 25

EEx d junction and control box F-900.001 In this EEx d junction box all potential free signals can be picked off.

Terminal 1 and 2: Motor shutdown Terminal 3 and 4: Purging in progress Terminal 5 and 6: Motor not purged Terminal 7 and 8: Purging sequence finished Terminal 9 and 10: Ready to start Terminal 11 and 12: Spare (wiring to F-900.041 terminals 5 and 6)

The EEx d box consists of: 2 x PE terminals type USLKG 6 6 x terminals type UKK 5 1 x bore hole ½“ NPT 1 x Bore hole ¾“ NPT 1 x EEx d cable gland type FL1 I1B (used by ELB) 1 x EEx d cable glands type FL1 I1B (cable ø = 10,5 – 12 mm)

for signal cables Cable glands for other diameters or armoured cables on request. Terminal block

9531

10642

642 10

531 9

PE PE

7

7

8

8

11

12

12

11

-X2

531 97 11

PE

-X2

62 4 8 10

62 4 8 10

12

12

51 3 7 9 11

PE

Page 18: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 17

Änd./

Mod.

15.07.2003 page 17 of 25

Wiring plan

Potential free contacts

control

1 2 3 4 5 6 7 8 9 10

K2 K3

LPE Npower supply

control valveleakage compensation

drive

A1

A2

A2

A1

13

14

23

24

K3

12

11

22

21

K3

purge valve

main switch

F-351

L N PE 1 2

power supply

(3) (4)

(1) (2)

PE PE

EEx d enclosure F-900.041

purging in progress

EEx prelease

K1 N L

3 4

purging in progress

F1

7

-X1

22

21

14 34

11

34

31

31

1 2 3 4 5 6 7 8 11 12PE PE

EEx d enclosure F-900.041

EEx d enclosure F-900.001

purging inprogress

motor not purged

purge sequence finished

ready tostart

(1) (2) (4)(3) (5) (6) (7) (8) (10)(9)

spare

9 10

65

(11) (12)

3 4

44

41

44

K2

41

motorshutdown

-X2

K3

Page 19: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 18

Änd./

Mod.

15.07.2003 page 18 of 25

Name plate

.L.B. EX-GERÄTE

TÜV 02 ATEX 1801 Operating voltage:

Motor Manufacturer:

Project name:

Serial no.:

VAC/48-62 Hz VDC

Order no.:

Project no.:

Date of pass:

EEx-p System Type F-361.C4

For the identification of the system a stainless steel plate is fixed at the enclosure of the control cabinet.

Page 20: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 19

Änd./

Mod.

15.07.2003 page 19 of 25

Checklist and test certificate

Test certificate and checklist for motor systems

customer:

address:

motor system: F-361.C4

power supply: ___ V ____ Hz date of pass: __.__.____ serial number: ___ order number: __________

checked by E.L.B. date:

name:

Page 21: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 20

Änd./

Mod.

15.07.2003 page 20 of 25

Appendix A Timing diagram purging sequence

T1: Switching on power supply and opening air pressure supply the control unit begins with a self test and the purging sequence of the EEx p motor enclosure starts. With an air flow which is higher than the adjusted value “min air flow” and the air flow is adequate the adjusted purge volume (min. 10-fold inner free motor volume), the motor enclosure is purged.

T2: The purging sequence is finished. The adjusted motor enclosure overpressure is controlled by the leakage compensation (see chapter 5 of main manual). The Non- Ex units can be powered.

T3: Normal operation starts.

Timing diagram operating modus

T1: The purging sequence is finished. The adjusted motor enclosure overpressure is controlled by the leakage compensation (see chapter 5 of main manual). The Non- Ex units can be powered.

T2: Normal operation starts. The internal enclosure overpressure is regulated to the setpoint value.

T3: The internal enclosure pressure rises.

T4: The increased overpressure is controlled down with the proportional valve.

T5: Normal operation begins.

Page 22: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 21

Änd./

Mod.

15.07.2003 page 21 of 25

Timing diagram errors during purging sequence

T1: Switching on power supply and opening air pressure supply the control unit begins with a self test and the purging

sequence of the EEx p motor enclosure starts. With an air flow which is higher than the adjusted value “min air flow” and the air flow is adequate the adjusted purge volume (min. 10-fold inner free motor volume), the motor enclosure is purged.

T2: During the purging sequence the internal overpressure increases to an excessively high value. The purge operation is aborted.

T3: During the purging sequence the minimum air volume flow falls. The purging sequence is resetted.

Timing diagram errors during the operating modus

T1: The purging sequence is finished. The adjusted motor enclosure overpressure is controlled by the leakage

compensation (see chapter 5 of main manual). The Non- Ex units can be powered.

T2: Normal operation starts. The internal enclosure overpressure is regulated to the setpoint value.

T3: The internal enclosure pressure drops. If the pressure value falls below the switchpoint „Minimum pressure“ in relation to the external pressure, the Non- Ex units are switched off.

T4: Renewed purge.

T5: Normal operation begins.

T6: The internal enclosure pressure rises. The increased internal enclosure pressure cannot controlled down.

T7: If the internal pressure value exceeds the switchpoint „Overpressure“, the Non- Ex units are switched off. The purge valve is powered, so the outlet valve opens. The increased overpresse sinks to operation values.

T8: After the pressure decrease, normal operation begins without purging.

Page 23: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 22

Änd./

Mod.

15.07.2003 page 22 of 25

Leakage compensation diagram To determine the approx. leakage of your purged motor enclosure during operation please count the turnarounds of the adjustment valve „leakage comp.“ (Pos.12) and use this diagram.

Leakagecompensation F-361.C4

05

1015202530354045505560657075808590

0,00 0,25 0,50 0,75 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25

Turns for adjustment valve"leakage comp." (Pos.12)

Leak

age

in N

m3 /h

bei 3 Bar Max.leakage compensation with proportional valvel

Page 24: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 23

Änd./

Mod.

15.07.2003 page 23 of 25

F-369PE

2 4 6

1 3 5PE

Option: Evaluation of additional signals If wanted, the evaluation of more potential free signals is possible. Therefore the module F-369 will be mounted. This module is directly controlled via EEx i circuits of the control unit F-351.P. Each relay (K2, K3 and K4) is free programmable in his function. The module F-369 itself is mounted in an EE x d enclosure type F-900.031F369. An exchange of the F-900.031F369 against the F-900.001 in already operating systems is only possible, if the control unit is also changed. EEx d control box F-900.031F369 In this EEx d junction box all potential free signals can be picked off. Layout of the cable glands can be different from sketch.

Terminal 1 and 2: Motor stop Terminal 3 and 4: Purging in progress Terminal 5 and 6: Operate F-369 1/2 (K2): free programmable F-369 5/6 (K3): free programmable F-369 9/10 (K4): free programmable

Power supply has to be connected to F-369 terminals 14 (PE)/15 (L1)/16 (N). The intrinsic safe circuit cable is direct wired to the socket at the left side of the control unit F-351.P. The EEx d box consists of: 2 x PE terminals type USLKG 5 3 x terminals type UKK 5 1 x opto-relay module F-369 5 x bore hole ½“ NPT 1 x EEx d cable gland type FL1 G1B (used by ELB) 1 x EEx d cable gland type FL 01 F1B for EEx i wiring (used by ELB) 1 x EEx d cable glands type FL1 I1B (cable ø = 10,5 – 12 mm) for signal cable (client)

Page 25: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 24

Änd./

Mod.

15.07.2003 page 24 of 25

Programming the additional potential free contacts K2, K3, K4 All contacts can be programmed as NC or NO. The function of each relay is programmable as listed:

isolation contact switches simultaneous with contacts at terminals (6) and (7) of F-351

system fault contact switches in case of a fault malfunction 1 minute contact switches 1 min after fault

malfunction flashing contact switches 1 min after fault and switches over in a cycle of 1 sec

pre-alarm “Min” when the internal enclosure pressure drops under the adjusted value of “Min”, range 0,8 – 15 mbar

pre-alarm “Max” switches when the internal enclosure pressure rises above the adjusted value of “Max”, range 0,8 – 24 mbar

purge contact switches during purging sequence bypass contact switches, if bypass key-switch is active

fault/bypass fault: contact switches in case of a fault bypass: contact switches over in cyle of 1 sec

Extended wiring plan

drive

power supply

13

(1)

14

mainswitch (3)

-X1 L

PEpower supply

F-351.P

L N

21 3

K1

4

controlN

5 6

L

7

purge valve

23

(2)

24

(4)

purging inprogress

3

N PE 1 2 PE

A1

A2

K24

K3A2

A1 11 21

K3K3

12 22

PE

leakage valve

108 9

7

F1

EEx d enclosure F-900.041

F-900.031

EEx i socket

intrinsic safecircuit

purging inprogress

Page 26: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

Description EEx-p System F-361.C4 25

Änd./

Mod.

15.07.2003 page 25 of 25

Potential free contacts

K3

K2

EEx d enclosure F-900.041

41

44

41

3

44

4

EEx d enclosure F-900.031

-X2 PE 1 2 3 4

purging inprogress

K3

34

31

31

34

K2

5 6

operate

PE

motor stop

F-36

9/K2

F-36

9/K3

F -36

9/K4

free programmable contacts

L N PE

F-369

intrinsic safe circuit from F-351.P

wiring to F-900.041terminal 1 and 2

contact 1 contact 2 contact 3

The electronic is designed to work according to the “closed-circuit principle”

Page 27: 17-1B AOP E04 50217 0001 01L - Amazon Web Services · 07.04.2006 / QBS Bachmann ... RAL 7032 Protection class: IP 23 ... Certified by: PTB 00 ATEX 2202 X Operating range:

EC Declaration of Conformity E.L.B. Ex-Geräte

We hereby confirm the conformity of the equipment listed below with the directives of the Council of the European Community. The safety and installation instructions of the product documentation must be observed.

Model: EEx px Purge System F-35... and F-361.A4/.B4/.C4/.F4, consist of: -EEx px Controller F-351 -EEx m digital / proportional valves F-220.2/.2B/.3/.4

-EEx d box (es) -EEx m main switch -EEx d cable glands -EEx e cable glands

Directive: EMC Directive 98/336/EC)*

European standards: EN 50081-1, 3/93*) EN 50081-2, 3/93*) EN 50082-1, 2/96*) EN 50082-2, 2/96*)

Directive: Low Voltage Directive 73/23/EC*)

European standard: EN 61010-1 :3/94

Directive: ATEX 94/9/EC European Standards: EN 60079-0 :2006 EN 60079-2 :2004 EN 60954-1 :1996 EN 60079-7 :2003 EN 60079-11:2007 EN 60079-18:2004

A quality management system according to DIN EN ISO 9001 (reg.-no. 8000307346) and ATEX 94/9 is established since 1998 and will be periodly supervised from a notified body (TÜV CE0032/ 0044).

Managing Director E.L.B. Ex-Geräte Bachmann GmbH&Co KG, Postadress: An der Hartbrücke 8, 64625 Bensheim, Germany Phone: +49 6251 637 36, Fax: +49 6251 637 29 E-Mail: [email protected], [email protected] Commercial Register of Bensheim, HRB No. 21728, Managing Director: S. Bachmann Trademark™ and registered trademarks ®

High-Flow Technology™ - trademark of the E.L.B. company. Permits low enclosure pressures even for high air flowrates

Wheel-Shuttle® - Patented and registered trademark of the University of Dresden and the E.L.B. company. Operating and parametrization for the EEx-p controller F-351 with simple, intuitive operator guidance.