172047 Av

Embed Size (px)

Citation preview

  • 7/27/2019 172047 Av

    1/34

    PROGRAMMINGGUIDE

    for

    BARCODESCANNERS

    This guide is especially used

    for barcode scanner sof tware of

    Version V2.11R 2007/1/12

    Shenzhen Dazhen Barcode Technology Co., Ltd.

  • 7/27/2019 172047 Av

    2/34

    NOTICE

    This is a general guide for varies scanners,and notal functions will perform in every scanners. Otherthan specified in this guide, for any specialfunctions or specifications, please contact yourdealer for details.

    Specification or version may be subject to changewithout notice. The actual specification and versionare based on the product delivered.

    TABLE OF CONTENTS

    Introduction ............................................................1

    Default Parameters................................................2

    Program Procedure ...............................................5

    System Setting ......................................................6General ConfigurationScanning Mode Selection ......................................9

    Inter- Message Delay...........................................10

    Inter- Character Delay ......................................... 11

    Message/ Block Mode Selection.......................... 11

    Beeper Tone Selection.........................................12

    Interface Configuration

    RS-232C Serial Communication Parameters Setting

    Handshaking Protocol .................................15

    ACK/ NAK Response Time Setting .............16

    Baud Rate ...................................................16

    Data Bit .......................................................17

    Stop Bit........................................................17

    Parity Setting ...............................................17

    Message Terminator ....................................18Keyboard Emulation Parameters Setting .............19

    Keyboard Type Selection ............................19

    Language Selection ....................................21Message Terminator ....................................22

    Function Key Emulation ..............................23

    Capital Lock Setting ....................................23

    Wand Emulation Parameters Setting ...................24

    Emulation Data Output Selection ................25

    Wand Emulation Narrow/Wide Ratio ...........25

    Cursor Pad Work at Numlock ......................25

    USB Interface Parameters Setting.......................26

    Keyboard Type ............................................26

    Message Terminator ....................................26

    The Symbologies

    Reading Code Selection ......................................28Code 39 Parameters Setting ...............................30

    Interleaved 2 Of 5 Parameters Setting.................31

    1

  • 7/27/2019 172047 Av

    3/34

  • 7/27/2019 172047 Av

    4/34

    3. DEFAULT PARAMETERS DEFAULT VALUES OF KEYBOARD EMULATIONPARAMETERS SETTING

    This table gives the default settings of all theprogrammable parameters. The default settings willbe restored whenever the "Reset" programminglabel is scanned.

    This table gives the default settings of all theprogrammable parameters. The default settings willbe restored whenever the "Reset" programminglabel is scanned.

    Function Default Values

    Keyboardtypeselection IBMPC/ATUSA

    Messageterminator Enter/carriage

    ReturnDEFAULT VALUES OF OPERATING PARAMETERSDEFAULT VALUES OF OPERATING PARAMETERS

    DEFAULT VALUES OF RS-232C SERIALCOMMUNICATION PARAMETERSFunction DefaultValues

    ScanningModeSelection Triggermode

    Headerandtrailer None

    Inter-Messagedelay Normal

    Inter-Characterdelay Normal

    Message/Blockmodeselection MessageSendcommandinblockmodecommunication

    Disable

    Goodreadbeepertoneselection Medium

    Codeidentifiertransmitting Disable

    Function Default Values

    Handshakingprotocol None

    ACK/NAKresponsetime

    settin300msec

    Baudrate 9600

    Databit 8

    Stopbit 1

    Parity Mark

    Messageterminatorselection

    CR/LF

    PREDEFINED BARCODE IDENTIFIERS DEFAULT VALUES OF WAND EMULATIONPARAMETERS

    Code39barcodeidentifiercode M

    ITF2of5barcodeidentifiercode I

    Chinesepostcodeidentifiercode H

    UPC-Ebarcodeidentifiercode E

    UPC-Abarcodeidentifiercode A

    EAN-13barcodeidentifiercode F

    EAN-8barcodeidentifiercode FF

    Codabarbarcodeidentifiercode N

    Code128barcodeidentifiercode K

    Code93barcodeidentifiercode L

    MSIbarcodeidentifiercode P

    MATRIX25barcodeidentifiercode

    G

    Function Default Values

    Wandemulationspeed Normal

    Wandemulationoutput Black=High

    **Note: For wand emulation, the configuration isonly effective for the items with asterisk (*).

    DEFAULT VALUES OF USB EMULATIONPARAMETERS

    Function Default Values

    KeyboardType USKeyboardMessageTerminator Enter

    *

    **

    2 3

  • 7/27/2019 172047 Av

    5/34

    DEFAULT VALUES OF DECODING PARAMETERS 4. PROGRAM PROCEDURE USING BARCODEMENUS

    Function Code Default ValueCode39 EnableITF2of5 Enable

    ChinesePostCode DisableUPC/EAN/JAN Enable

    Codabar Enable* MSI Disable

    Code128 EnableCode93 Enable

    * ITAT Disable

    * EAN-128 Disable

    * MATRIX25 Disable

    * ItalianPharmacy Disable

    Readingcodes

    Selection

    ISSN/ISBN DisableCodes StandardStart/stopcharacters Nottransmitting

    Checkdigit Disabled

    Code39

    Concatenation Off Length 6-32digitsInterleaved

    2of5 Checkdigit DisableLength 10~16digitsChinesePost

    Code Checkdigit TransmitFormat All

    Addendum DisableUPC-E=UPC-A Disabled

    UPC-Aleading digit TransmitUPC-Acheck di it Transmit

    UPC-Eleading digit Transmit

    UPC/EAN/JAN

    UPC-Echeck digit TransmitType Standard

    Start/stopcharacters A,B,C, D

    CodabarLength 6~32digits

    FNC2append DisableCode128Checkdigit Disable

    Length VariableMSICheckdigit Transmit

    ItalianPharmacy Transmit"A"Character

    Nottransmitting

    Length Fix 10digitsMATRIX25Checkdi it Disable

    Note: The configuration of the items with asterisk(*) is effective when being appointed in advance.

    4 5

  • 7/27/2019 172047 Av

    6/34

    StartofConfiguration

    RESET

    Thereadingofthe"RESET

    label turns all theparameters back to defaultvalues.When you intend toturn your scannerback todefaultparameter, pleasescans the "Start ofconfiguration" label first,thenscan"RESET"label

    SYSTEM SETTINGABORT

    RS-232C

    PC/AT

    USB

    WAND

    The reading of the "ABORT"

    label discards all theparametersreadpriortothe

    "Endofconfiguration".

    The scanner remains inthe

    last interface mode

    when the scanner isreset.

    The label below should be

    scanned if the scanner

    is configuredthefirsttime.

    Thereadingof the SHOWV VERSIONlabelwill be showf firmwareversion.

    SHOWVERSION

    End ofConfiguration6 7

  • 7/27/2019 172047 Av

    7/34

    StartofConfiguration

    SCANNING MODE SELECTION (for laser scanner)Forseries laserscanners, thereare3scanningmodes tosuit

    yourapplicationrequirements.The scanner becomes inactiveas soon as the data istransmitted. It mustbe

    TriggerMode

    PulseMode

    triggered to becomeactive again.

    Thescanner will lightup whenpress the pulse mode

    trigger switch once. And, thescanner will turn off fornext pressing.

    GENERAL

    CONFIGURATION

    SCANNING MODE SELECTION (For CCD scanner)

    The scanner becomes inactiveas soonasthedataistransmitted.

    Trigger modeIt must be triggered to becomeactive again.

    In auto scan mode, thescanner isstill active after the data istransmitted, but the successivetransmissionof thesamebarcodeis not allowed when thetrigger switchispressedagain.

    This scanner will light up whenpress the scanner trigger switchonce. And,thescanner will turnofffornextpressing.

    This mode is similar to Autoscan mode, but double readingfor the same barcode isprohibited if the scanner switch

    ispressed.

    Autoscanmode

    Alternatemode

    Repeatmode

    EndofConfiguration8

    9

  • 7/27/2019 172047 Av

    8/34

    StartofConfiguration

    DATA REDUNDANT CHECK

    The option allows you toset decoderdata redundantcheck. Enable

    INTER-CHARACTER DELAYThis option governs delay time between consecutivecharacters. Scanning the following labels can alter thedelay time.

    None

    Disable

    10msec

    INTER-MESSAGE DELAYThese series of scanners allow you to add adelay between two consecutive messages. This delay willbe added before each data transmission.

    None

    100msec

    500msec

    20msec

    50msec

    MESSAGE/BLOCK MODE SELECTIONThis option allows you to treat scanned data as either anindependent message or a block message. In

    the message mode, the data scanned will betransmitted immediately. In block mode, the datascanned will be appended to the message buffer ifthe scanner is programmed in block mode. A blockof message will only be transmitted after a Send commandis entered. This mode is only available when the scanner isworking with code 39 labels. You are free to chooseany character as the Send command.

    Messag

    1Second

    Block

    EndofConfiguration10 11

  • 7/27/2019 172047 Av

    9/34

    SOUND DURATION

    StartofConfigurationStartofConfiguration

    SEND COMMAND IN BLOCK MODESEND COMMAND IN BLOCK MODECOMMUNICATIONYou can use this option to set your own Send commandused in block mode communication.

    long(120ms)

    Medium(50ms)

    EnableShort(20ms)

    DisableVeryshort(5ms)

    Store

    Set

    GOOD READ BEEPER TONE SELECTIONYou can use this option to set frequencyand/or duration of the buzzer after successful reading.

    Medium

    Low

    High

    Disable

    12

    EndofConfiguratio

    13

  • 7/27/2019 172047 Av

    10/34

    StartofConfiguration

    1. RS-232C SERIALCOMMUNICATIONPARAMETERS SETTING

    The RS-232C scanner supports four handshaking protocols.With these options of communication protocol, you can tailorthe scanner to meet the requirement of most systems

    HANDSHAKING PROTOCOL

    None

    INTERFACECONFIGURATION

    RTS/CTS

    ACK/NAK

    Xon/Xoff

    ACK/NAK RESPONSE TIME SETTING

    300msec

    2sec

    500msec

    14

    15EndofConfiguration

  • 7/27/2019 172047 Av

    11/34

    DATA BIT

    StartofConfiguration

    ACK/NAK RESPONSE TIME SETTING (Contd)7

    3sec

    8

    STOP BIT

    1sec1

    5sec

    BAUD RATE

    2

    PARITY

    19200

    Even

    9600Odd

    4800

    2400Space

    1200

    None

    600

    EndofConfiguration

    16 17

    Mark

  • 7/27/2019 172047 Av

    12/34

    StartofConfiguration

    MESSAGE TERMINATOR (FOR RS-232CONLY)

    None

    2.KEYBOARD EMULATION PARAMETERSSETTING

    KEYBOARD TYPE SELECTIONThe keyboard emulation scanners can emulate anumber of personal computers keyboard and a

    number of terminal keyboard.Keyboardemulationisactivatedwheneveryouhave selectedthetypeofkeyboardforwhichthescannerisgoingto emulate.Choosetheappropriatetypeofkeyboardemulationby scanningthelabelsunderthefollowinglabels.

    CR/LFIBMAT

    CRPS/230-80

    LFIBM5550

    HTabIBM5295Terminal

    STX/ETXIBMXT

    EOT IBM5530-SC

    IBM5530-ZC

    EndofConfiguration

    18 19

  • 7/27/2019 172047 Av

    13/34

    KEYBOARD LANGUAGE SELECTION

    StartofConfigurationStartofConfiguration

    KEYBOARD TYPE SELECTION (Cont d)KEYBOARD TYPE SELECTION (Cont d) USA

    NEC9801 UK

    IBM3196Terminal Germany

    APPLEMACII() French

    IBM3477/3472Terminal Spanish

    PS2/30/56 Italian

    IBM3477Terminal(Withoutbreakcode)

    Swiss

    NEC5200()

    Note: The configuration of the items with asterisk (*) isoptional.

    Swedish

    20 21

    EndofConfiguration

  • 7/27/2019 172047 Av

    14/34

    StartofConfiguration

    FUNCTION KEY ACTIVE ON/ OFF (FOR IBM AT USE)Function keys can be concatenated with input data asheader and/or trailer. See table on page 40.

    MESSAGE TERMINATOR (FOR KEYBOARD WEDGEUSE)

    ON

    None

    OFF

    Return/Enter CAPITAL LOCK ON/ OFFSelect the suitable code to match your keyboard caps lockstatus.

    Hor.TAB

    ON

    Execute

    KEYBOARD TYPE SELECTION

    ScanCodeMode

    OFF

    Funct ion key emulation (only for PC/AT)

    Numlock on/off

    OFF

    Altmode

    BREAK CODE ON/ OFF SETTING (FOR IBM

    ONTerminals 31xx, 34xx, 37xx USE)

    To select the interface for these IBM terminals, read thecorrect key transmission code.

    ON

    OFF

    22

    EndofConfiguration

    23

  • 7/27/2019 172047 Av

    15/34

    StartofConfiguration

    EMULATION DATA OUTPUT SELECTIONThe decoded data output logic level can be set to befitthe external decoder.the external decoder.

    00H~1FH ASCII Code defined00H~1FH ASCII Code defined

    Black=High

    Alt-mode code

    Crtl+code

    Black=Low

    WAND EMULATION NARROW/WIDE RATIO

    1:2

    3.WAND EMULATION PARAMETERSSETTING

    EMULATION SPEED SELECTION

    1:3

    CURSOR PAD WORK AT NUMLOCK

    ON

    Low

    OFF

    Medium

    Normal

    High

    Higher

    24

    EndofConfiguration

    25

  • 7/27/2019 172047 Av

    16/34

    StartofConfiguration

    4.USB INTERFACE PARAMETERSSETTING

    The USB mode is effectively a keyboard emulator that

    works with hosts that USB-compatible operating system and

    USB ports. USB compatible operating systems areWindows 98, Windows NT 5.0 and later, no additional

    software is needed since the USB driver support is built into this

    operating system.

    KEYBOARD TYPE

    USKeyboard

    InternationalKeyboard

    MESSAGE TERMINATOR

    THE SYMBOLOGIES

    None

    Enter

    HTab

    EndofConfiguration

    26 27

  • 7/27/2019 172047 Av

    17/34

    StartofConfiguration Code128Disable

    READING CODE SELECTION

    MSIEnable

    Code39Enable

    MSIDisable

    Code39Disable

    Code 93 Enable

    CodabarEnable

    Code93Disable

    CodabarDisable

    IATAEnable

    UPC/EAN/JANEnable

    IATADisable

    UPC/EAN/JANDisable

    EAN-128Enable

    ITF2of5Enable

    EAN-128Disable

    ITF2of5Disable

    MATRIX25Enable

    ChinesePostCodeEnable

    MATRIXDisable

    ChinesePostCodeDisable

    Code128Enable

    28

    EndofConfiguration29

  • 7/27/2019 172047 Av

    18/34

    StartofConfiguration

    READING CODE SELECTION (Contd)

    NOCONCATENATION

    Enable

    ItalianPharmacyEnable

    Disable

    ItalianPharmacyDisable

    CODE 39 PARAMETERS SETTING

    CHARACTER SET

    INTERLEAVED 2 OF 5 PARAMENTERS SETTING

    Examples: Felting length 4 to 8 digits

    LENTGTH

    StandardCode39

    FullASCIICode39

    START/STOP CHARACTER TRANSMISSION

    Scan:.Startofconfiguration

    Min

    0

    4

    set

    max

    0

    8

    set

    Endofconfiguration

    MAX

    Min

    YesSet

    No

    CHECK DIGIT

    CalculateandTransmit

    CalculatebutnotTransmitEndofConfiguration

    30 31

    CHECK DIGIT

  • 7/27/2019 172047 Av

    19/34

    CHECK DIGIT

    StartofConfiguration

    NOCHECK DIGIT

    CalculateandTransmit

    NO

    CalculateandTransmit

    CalculatebutnotTransmit

    UPC/EAN/JAN PARAMETERS SETTING

    FORMAT

    CalculatebutnotTransmit

    CHINESE POST CODE PARAMETERS SETTING

    All

    LENGTH

    Scan:.Startof

    configuration max

    EAN-8orEAN-13

    MAX

    MIN

    Set

    Min

    0

    4

    set

    0

    8

    set

    Endofconfiguration

    UPC-AandEAN-13

    UPC-AandUPC-E

    UPC-A

    UPC-E

    EndofConfiguration

    32 33

    FORCE UPC-A TO EAN-13 FORMAT

  • 7/27/2019 172047 Av

    20/34

    StartofConfiguration

    UPC/EAN/JAN PARAMETERS SETTING (Contd)

    Yes

    EAN-13

    No

    TRANSMIT UPC-A LEADING CHARACTER

    EAN-8

    ADDENDUMYes

    NoNO

    TRANSMIT UPC-A CHECK DIGIT

    5Characters

    Yes

    2Characters

    2or5Characters

    FORCE UPC-E TO UPC-A FORMAT

    No

    TRANSMIT UPC-E LEADING CHARACTER

    Yes

    Yes

    No

    No

    EndofConfiguration

    3534

    CODABAR/ MONARCH PARAMETERS SETTING

  • 7/27/2019 172047 Av

    21/34

    StartofConfiguration

    CODABAR/ MONARCH PARAMETERS SETTING

    START/ STOP CHARACTER TRANSMISSION

    TRANSMIT UPC-E CHECK DIGIT No

    Yes

    A,B,C,D

    No

    TRANSMIT EAN-13 CHECK DIGIT DC1~DC4

    Yesa/t,b/n,c/*,d/e

    CONCATENATION

    No

    TRANSMIT EAN-8 CHECK DIGIT

    Enable

    Disable

    YesCODE 128 PARAMETERS SETTING

    FNC 2 CONCATENATION

    No

    Enable

    Disable

    EndofConfiguration36 37

    MSI/PLESSY PARAMETERS SETTING

  • 7/27/2019 172047 Av

    22/34

    StartofConfiguration

    MSI/PLESSY PARAMETERS SETTING

    Examples: Felting length 4 to 8 characters

    Scan:.StartScan:.Start

    CODE 128 PARAMETERS SETTING (Contd)CODE 128 PARAMETERS SETTING (Contd)

    CHECK DIGIT

    No

    MAX

    MIN

    ofconfiguration

    Min

    0

    4

    set

    max

    0

    8

    set

    Endofconfiguration

    CalculatebutnotTransmit SET

    Double Check digit

    CalculateandTransmit

    UCC/EAN128 PARAMETERS SETTINGThe character FNC1 can be transmitted or notusing these codes.

    CalculatebutnotTransmitted

    FNC1CharacterTransmitted No

    FNC1notTransmitted CalculatebutonlyfirstoneTransmitted

    MATRIX 25 PARAMETERS SETTING

    Examples: Felting length 4 to 8 characters

    Scan.Startofconfiguration max

    CalculatedandbothTransmitted

    Single Check digit

    MAX

    MIN

    Min

    0

    4

    set

    0

    8

    set

    Endofconfiguration

    CalculatedbutnotTransmitted

    Calculatedandtransmitted

    Set38 EndofConfiguration

    39

    BARCODE LENGTH SETTING

  • 7/27/2019 172047 Av

    23/34

    StartofConfiguration

    BARCODE LENGTH SETTING

    CODE 39 LENGTH SETTING

    MSI/PLESSY PARAMETERS SETTING (Contd)MSI/PLESSY PARAMETERS SETTING (Contd) MAX

    PLESSY CODE SETTING

    Calculatedandtransmitted

    MIN

    CODE 93 LENGTH SETTING

    Calculatebutnottransmitted

    CHECK DIGHT

    MAX

    MIN

    CODE 128 LENGTH SETTING

    No

    MAX

    CalculateandTransmit

    Calculate but notTransmit

    MIN

    CODABAR LENGTH SETTING

    ITALIAN PHARMACY PARAMETERS SETTING

    TRANSMIT "A" CHARACTERMAX

    Yes MIN

    No SET

    Endof onfiguration40 41

  • 7/27/2019 172047 Av

    24/34

    StartofConfiguration

    ISBN/ ISSN CONVERSION

    The function convents the UPC/EAN codes appearing

    on books and magazine not ISBN/ISSN format.

    ACTIVEISBN/ISSN

    INACTIVEISBN/ISSN

    DATA EDITING

    EndofConfiguration

    42 43

    BARCODE IDENTIFIER CODE SETTING

  • 7/27/2019 172047 Av

    25/34

    StartofConfiguration

    HEADER AND TRAILERThis option allows you to append a header and/ora trailer to every message transmitted via the serial ports orthe keyboard port. There is no restriction in selecting headeror trailer characters as far as the sum of thelengths of header and trailer is not greater than 10 digits.

    Each of the series type scanners can set max.2 digits asbarcode identifier code according to different barcode.The procedure is as follows:1. Scan Start of configuration label2. Scan Barcode identifier setting code label.3. Scan the new code mark from ASCII table (max. two digits).

    For example, if one AB want for code mark then scan Aand B.

    4. Scan Set label.5. Scan End of configuration label.

    Header

    Trailer

    1. Select either header ortrailer

    you are going toprogram by scanning thecorresponding label

    2. Scan the character(s) you

    want from the enclosed ASCIItable to set as header or trailer(be sure to enable fullASCII code 39 option beforeyou start).

    3. Read the Set label to set yourchoice into memory.

    UPC-E

    UPC-A

    Set

    BARCODE IDENTIFIER CODE SELECTIONThe series of scanners can transmit max.2-digit barcodeidentifier code for different types of barcodes. Use the labels

    to choose transmit or not transmit predefinedbarcode identifier code (IDs are listed on page 2):

    EAN-13

    EAN-8

    Chinesepostcode

    Enable

    ITF2OF5

    Disable

    EndofConfiguration44 45

    Truncate Header/Trailer Character

  • 7/27/2019 172047 Av

    26/34

    StartofConfiguration

    BARCODE IDENTIFIER CODE SETTING (Contd)

    (Version V2.00R or higher is required)

    You can truncate a number header or trailer for a symbology.

    When you do, the specific character you select is deleted

    from the symbology you want.

    Codabar

    Code39

    Code128

    Truncate header character

    Truncate trailer character

    set

    1.scanstart of con-figuration2.selecttruncateheader or truncatetrailer3.scan two barcodevalue from the full

    ASCII code table(

    0~9) For example, if 2

    number header

    you want clear thenscan 0 and 2

    Code93 4.Scan SET barcode

    5.End of configuration

    MSI

    MATRIX25

    Set

    EndofConfiguration

    47

    46

    CODE 39 FULL ASCII CODE TABLE

  • 7/27/2019 172047 Av

    27/34

    ASCIICODE

    39VALEUR

    ASCIICODE

    39VALEUR

    NUL %U 00 % /E 25SOH A 01 & /F 26STX B 02 ' /G 27ETX C 03 /H 28EOT D 04 /I 29ENQ E 05 * /J 2AACK F 06 + /K 2BBEL G 07 /L 2CBS H 08 - - 2DHT I 09 . . 2ELF $J 0A / / 2FVT K 0B 0 0 30FF L 0C 1 1 31CR M 0D 2 2 32SO N 0E 3 3 33SI O 0F 4 4 34

    DLE P 10 5 5 35DC1 Q 11 6 6 36DC2 R 12 7 7 37DC3 S 13 8 8 38

    DC4 T 14 9 9 39NAK U 15 : /Z 3ASYN V 16 %F 3BETB W 17 < %G 3CCAN X 18

    APPENDIXES

    = %H 3DEM Y 19 > %I 3ESUB Z 1A ? %J 3FESC %A 1B %V 40FS %B 1C A A 41GS %C 1D B B 42 RS %D 1E C C 43US %E 1F D D 44SP SP 20 E E 45

    ! /A 21 F F 46" /B 22 G G 47# /C 23 H H 48

    /D 24 I I 49

    48APPENDIX A

    49

    APPENDIX A

    CODE 39 FULL ASCII CODE TABLE FUNCTION KEY EMULATION

  • 7/27/2019 172047 Av

    28/34

    ASCIICODE

    39VALEUR

    ASCIICODE

    39VALEUR

    J J 4A e +E 65K K 4B f +F 66L L 4C +G 67

    M M 4D h +H 68N N 4E i +I 69O O 4F +J 6AP P 50 k +K 6BQ Q 51 l +L 6CR R 52 m +M 6DS S 53 n +N 6ET T 54 o +O 6FU U 55 +P 70V V 56 +Q 71W W 57 r +R 72X X 58 s +S 73Y Y 59 t +T 74Z Z 5A u +U 75

    %K 5B v +V 76\ %L 5C w +W 77

    %M 5D x +X 78

    ^ %N 5E +Y 79%O 5F z +Z 7A` %W 60 %P 7Ba +A 61 %Q 7Cb +B 62 %R 7Dc +C 63 ~ %S 7Ed +D 64

    DEL %T 7F

    FUNCTIONKEY

    ASCIICODE

    39FUNCTION

    KEY

    CODEASCII

    39Ins A 01 F1 Q 11Del B 02 F2 R 12

    End D 04 F4 T 14

    Down F 06 F6 V 16

    Backs ace H 08 F8 X 18

    Enter num J 0A F10 Z 1A

    P U L 0C F12 %B 1C

    P Dn N 0E Ctl L %D 1E

    5 num P 10

    50APPENDIX A 51

    APPENDIX B

    CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE

  • 7/27/2019 172047 Av

    29/34

    Start of Configuration

    NUL

    LF(Enter)(num)

    DLE5(num)

    SOH(Ins)

    STX(Del)

    ETX(Home)

    EOT(End)

    ENQ(Up)

    ACK(Down)

    BEL(Left)

    BS(Backspace)

    HT(TAB)

    VT(Right)

    FF(PgUp)

    CR(Enter)

    SO(PgDn)

    SIshift(L)

    DC1(F1)

    DC2(F2)

    DC3

    (F3)

    DC4(F4)

    NAK(F5)

    52

    APPENDIX B

    EndofConfiguration

    53

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

  • 7/27/2019 172047 Av

    30/34

    CODE 39 FULL ASCII BARCODE TABLE

    StartofConfiguration

    $

    SYN(F6)

    ETB(F7)

    +GS

    (ESC)

    %

    ,

    RS

    Ctl(L) &

    CAN(F8)

    -

    USAlt(L) '

    .

    EM(F9)

    SP (

    /

    SUB(F10)

    ! )

    0

    ESC(F11)

    " *

    1

    FS(F12)

    #

    54 55End of Configuration

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

  • 7/27/2019 172047 Av

    31/34

    CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE

    StartofConfiguration

    B2 I

    :

    C

    3 J

    ;

    D

    4 K

    G

    7 N

    ?

    H

    8 O

    @

    9

    A56 57 EndofConfiguration

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

  • 7/27/2019 172047 Av

    32/34

    StartofConfiguration^

    e

    P

    W _

    f

    Q

    X `

    g

    R

    Y a

    h

    S

    Z b

    i

    T

    [ c

    j

    U

    \ d

    k

    V

    ]

    EndofConfiguration

    58 59

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

    APPENDIX BCODE 39 FULL ASCII BARCODE TABLE

  • 7/27/2019 172047 Av

    33/34

    StartofConfigurationz

    l }

    s{

    m ~

    t|

    n DEL

    u

    o

    v

    p

    w

    q

    x

    r

    y

    60EndofConfiguration

    61

    APPENDIX C

    BARCODE SAMPLES

    APPENDIX D

    QUICK SETTINGS

  • 7/27/2019 172047 Av

    34/34

    BARCODE SAMPLES QUICK SETTINGS

    Please refer to:QUICK SET UP FPR PROGRAMMING CARD

    Code 39

    C O D E 3 9

    Code 128

    CODE128

    Interleaved 2 of 5

    1 23 45 6 78 90

    Coda bar(NW-7)

    A$99.95A

    UPC A

    0 4 4 2 52 3 0 2 4 5 1

    EAN-13

    4 7 11 234 567 89 962

    63