Upload
federico-maggi
View
29
Download
1
Embed Size (px)
Citation preview
www.marconi.com© 2005. The Copyright in this document belongs to Marconi Corporation plc andno part of this document should be used or copied without their prior written permission.
SMA 1/4 EX (OMS 1260)
2
The SMA 1/4 EX (OMS 1260)The SMA 1/4 EX (OMS 1260)The SMA 1/4 EX (OMS 1260)The SMA 1/4 EX (OMS 1260)
SMA1/4EX Full capacity Multi Service Network edge node STM-1/STM-4
•4 Line I/F + 5 Generic Tribs
•6 x STM-4
•18 x STM-1
•5 x 34 or 45Mbit/s PDH
•5 x 140Mbit/s PDH
•252 x 2Mbit/s PDH
3
SMA1/4 EXSMA1/4 EXSMA1/4 EXSMA1/4 EX
Power and LCT I/F
Core CCU/Switch CardTwo SFP module positionsSTM-1, STM-4 Optical STM-1 Electrical
Auxiliary Unit ProvidingTwo x Ext Timing I/P (T3)Two x Ext Timing O/P (T4)Qx Network Management I/F2M PDH Traffic Test PortBw7R Alarm IndicationFour Ext User Alarm O/PSix Ext User Alam I/P
Protection 63 x 2M Trib Card
Protection Power and LCT I/F Position
63 x 2M LTU Positions. Providing access to the Four 2 M Trib Cards
Four 63 x 2M Trib card Positions Mutually exclusive with equipping of adjacent Generic Trib slot
Protection Core Switch CardTwo SFP module positionsSTM-1, STM-4 OpticalSTM-1 electrical
Fan TrayFan Tray
4
SMA1/4 EXSMA1/4 EXSMA1/4 EXSMA1/4 EX
Power and LCT I/F
Protection Power and LCT I/F Position
Five Generic LTUs Provide Power for and access to the Generic Tributary slot positions
Five Generic Trib card Positions DataSlots 1 - 3 = 2 x VC-4 Bandwidth SDHSlots 4 - 5 = 4 x VC-4 Bandwidth PDH
5
SMA1/4 EXSMA1/4 EX
6
Rack Alarm Unit
Breaker Dist Panel
ETSI Rack
10
7976
18
OMS 1260 (EX) ETSI Rack & SubrackOMS 1260 (EX) ETSI Rack & SubrackOMS 1260 (EX) ETSI Rack & SubrackOMS 1260 (EX) ETSI Rack & Subrack
ONONON
OFF
ON
OFF
ON ONON
Screw position for mountingSMA1/4 EX subrack
Bay Face Layout
Screw position formounting breakerdistribution panel
7
63A-VE
6 A 10A 10 A63A+VE
63A-VE
63A+VE
Main Power Source 1
Main Power Source 2
RackAlarm
1/4 EX Power 2
(2)(3) (1)
(4) (5)(6)
Items Description
(1) Rack Mounted Breaker Distribution Board (490/IM0001BD/22) (2) Power Cable 16 Sqmm (Main) , Red (490/IM0002/22)(3) Power Cable 16 Sqmm (Main), Blue (490/IM0002/21)(4) Magnethothermic Breaker (MCB) , 6A (490/IM0001BD/23)(5) Magnethothermic Breaker (MCB) , 10A (490/IM0001BD/24)(6) Magnethothermic Breaker (MCB) , 63A (490/IM0001BD/26)
1/4 EX Power 1
DC Breaker Distribution Panel- 1/4 EXDC Breaker Distribution Panel- 1/4 EXDC Breaker Distribution Panel- 1/4 EXDC Breaker Distribution Panel- 1/4 EX
8
Rack Alarm Unit – Power SupplyRack Alarm Unit – Power SupplyRack Alarm Unit – Power SupplyRack Alarm Unit – Power Supply
Rack Alarm Unit – Power Connection
9
EX Subrack DimensionsEX Subrack DimensionsEX Subrack DimensionsEX Subrack Dimensions
SMA_EX
Height 445 mmWidth 448 mmDepth 280mm
10
SMA-1/4 EX SUBRACKs with 252x 2M PDH Balanced SMA-1/4 EX SUBRACKs with 252x 2M PDH Balanced Access LTUsAccess LTUs
SMA-1/4 EX SUBRACKs with 252x 2M PDH Balanced SMA-1/4 EX SUBRACKs with 252x 2M PDH Balanced Access LTUsAccess LTUs
2M PDH Trib 1LTU area(63-ports)
63x
2Mb
Pro
tn T
rib
Por
t Acc
ess
Are
aF
unct
iona
l Uni
t Car
d C
age
Slide-in Fan Unit
Gen
eric
Trib
1
63x
2Mb
Trib
2G
ene
ric T
rib 1
PS
U/L
TU
Ge
neric
Trib
2 P
SU
/LT
U
63x
2Mb
Trib
3
63x
2Mb
Trib
4
Ge
neric
Trib
3 P
SU
/LT
U
63x
2Mb
Trib
1
Gen
eric
Trib
3
Gen
eric
Trib
2
2M
b T
rib
LTU
1a
(po
rts
1-2
1)
Ge
neric
Trib
5 P
SU
/LT
UG
ener
ic T
rib 5
Ge
neric
Trib
6 P
SU
/LT
U
Gen
eric
Trib
4
‘UC
’ ST
M-1
/4 T
raffi
c C
ore
B
SF
P
I/F
SF
P
I/F
‘UC
’ ST
M-1
/4 T
raffi
c C
ore
A /
CC
U
SF
P
I/F
SF
P
I/F
(Exp
ansi
on)
Gen
eric
Trib
7
(Exp
ansi
on)
Gen
eric
Trib
6
Ge
neric
Trib
7 P
SU
/LT
U
Ge
neric
Trib
4 P
SU
/LT
U
2M
b T
rib
LTU
1b
(po
rts
22-4
2)
2M
b T
rib
LTU
1c
(po
rts
43-
63)
2M
b T
rib
LTU
2a
(po
rts
1-2
1)
2M
b T
rib
LTU
2b
(po
rts
22-4
2)
2M
b T
rib
LTU
2c
(po
rts
43-
63)
2M
b T
rib
LTU
3a
(po
rts
1-2
1)
2M
b T
rib
LTU
3b
(po
rts
22-4
2)
2M
b T
rib
LTU
3c
(po
rts
43-
63)
2M
b T
rib
LTU
4a
(po
rts
1-2
1)
2M
b T
rib
LTU
4b
(po
rts
22-4
2)
2M
b T
rib
LTU
4c
(po
rts
43-
63)
2M PDH Trib 2LTU area(63-ports)
Slide-in Fan Unit
2M Balanced LTUs 21 ports per LTU 12 LTUs max per Subrack (252 x 2M)
11
SMA1/4 EX Subracks Limited 126 x 2M PDH access via in SMA1/4 EX Subracks Limited 126 x 2M PDH access via in shelf LTU to Trib Slots 1 & 3shelf LTU to Trib Slots 1 & 3
SMA1/4 EX Subracks Limited 126 x 2M PDH access via in SMA1/4 EX Subracks Limited 126 x 2M PDH access via in shelf LTU to Trib Slots 1 & 3shelf LTU to Trib Slots 1 & 3
63x
2Mb
Pro
tn T
rib
Por
t Acc
ess
Are
aF
unct
iona
l Uni
t Car
d C
age
Slide-in Fan Unit
Gen
eric
Trib
1
63x
2Mb
Trib
2G
ene
ric T
rib 1
PS
U/L
TU
Ge
neric
Trib
2 P
SU
/LT
U
63x
2Mb
Trib
3
63x
2Mb
Trib
4
Ge
neric
Trib
3 P
SU
/LT
U
63x
2Mb
Trib
1
Gen
eric
Trib
3
Gen
eric
Trib
2
2M
b T
rib
LTU
1a
(po
rts
1-2
1)
Ge
neric
Trib
5 P
SU
/LT
UG
ener
ic T
rib 5
Ge
neric
Trib
6 P
SU
/LT
U
Gen
eric
Trib
4
‘UC
’ ST
M-1
/4 T
raffi
c C
ore
BS
FP
I/
FS
FP
I/
F
‘UC
’ ST
M-1
/4 T
raffi
c C
ore
A /
CC
US
FP
I/
FS
FP
I/
F
(Exp
ansi
on)
Gen
eric
Trib
7
(Exp
ansi
on)
Gen
eric
Trib
6G
ene
ric T
rib 7
PS
U/L
TU
Ge
neric
Trib
4 P
SU
/LT
U
2M
b T
rib
LTU
1b
(po
rts
22-4
2)
2M
b T
rib
LTU
1c
(po
rts
43-
63)
2M
b T
rib
LTU
2a
(po
rts
1-2
1)
2M
b T
rib
LTU
2b
(po
rts
22-4
2)
2M
b T
rib
LTU
2c
(po
rts
43-
63)
2M
b T
rib
LTU
3a
(po
rts
1-2
1)
2M
b T
rib
LTU
3b
(po
rts
22-4
2)
2M
b T
rib
LTU
3c
(po
rts
43-
63)
2M
b T
rib
LTU
4a
(po
rts
1-2
1)
2M
b T
rib
LTU
4b
(po
rts
22-4
2)
2M
b T
rib
LTU
4c
(po
rts
43-
63)
Slide-in Fan Unit
2Mbit Trib LTU 1(Ports 1 –63)
2Mbit Trib LTU 3(Ports 1 –63)
TRIB CARD 1 63x2M PDH
(Unbalanced)LTU Front Plate
TRIB CARD 3 63x2M PDH
(Unbalanced)LTU Front Plate
63 Port Unbalanced LTUs using front-plate PCB & 1.0/2.3 CO -AX connectors provides access to
2M Trib slots 1 & 3 (126 2M)
Access blocked to 2M Trib slots 2 & 4 and Generic Trib slots 1 & 3
12
Equipment LayoutEquipment LayoutEquipment LayoutEquipment Layout
1. 63x2Mb/s LTU
2. Generic LTU
3. Power LTU
4. STM-1/4 CoreCard
5. Generic Trib
6. Aux/Sync./Ancillary LTU
7. Fan Tray/Blanking late
12
3
4
5
6
7
13
Rack MountingRack MountingRack MountingRack Mounting
14
Slot Configuration and NumbersSlot Configuration and NumbersSlot Configuration and NumbersSlot Configuration and Numbers
15
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
LTU Area
S3 0
1 2
M L
TU
1A
S3 0
2 2
M L
TU
1B
S3 0
3 2
M L
TU
1C
S3 0
4 G
eneric T
rib 1
PS
U/L
TU
S3 0
5 2
M L
TU
2A
S3 0
6 2
M L
TU
2B
S3 0
7 2
M L
TU
2C
S3 0
8 G
eneric T
rib 2
PS
U/L
TU
S3 0
9 2
M L
TU
3A
S3 1
0 2
M L
TU
3B
S3 1
1 2
M L
TU
3C
S3 1
2 G
eneric T
rib 3
PS
U/L
TU
S3 1
3 2
M L
TU
4A
S3 1
4 2
M L
TU
4B
S3 1
5 2
M L
TU
4C
S3 1
6 G
eneric T
rib 4
PS
U/L
TU
S3 1
7 G
eneric T
rib 5
PS
U/L
TU
S3 1
8 G
eneric T
rib 6
PS
U/L
TU
S3 1
9 G
eneric T
rib 7
PS
U/L
TU
S3 2
0 P
ow
er
& L
CT
LT
U
S3 2
1 P
ow
er
& L
CT
LT
U
2M LTU Connectivity:1 1
1 - 21x2M, balanced 1 2 3 1 2 3 1 2 3 1 2 3
Card Area
S1_01 2
M T
rib 1
S1_02 G
eneric T
rib 1
S1_03 2
M T
rib 2
S1_04 G
eneric T
rib 2
S1_05 2
M P
rote
ction T
rib
S1_08 2
M T
rib 3
S1_09 G
eneric T
rib 3
S1_10 2
M T
rib 4
S1_11 G
eneric T
rib 4
S1_12 G
eneric T
rib 5
S1_13 G
eneric T
rib 6
S1_14 G
eneric T
rib 7
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15Slot Bandwidth [STM-1] 2 2 2 4 4 4 4
FAN Tray 1 FAN Tray 2
- 63x2M, unbalanced1
S1_06 T
raff
ic C
ore
B
S1_07 T
raff
ic C
ore
A /
CC
U
[bla
nk]
S1_15 C
om
ms/A
ux/A
ncilliary
Unit
TribGroup
1
TribGroup
2
TribGroup
3
TribGroup
4
Slot Configuration and NumbersSlot Configuration and NumbersSlot Configuration and NumbersSlot Configuration and Numbers
16
Comprises :-
• Switch functions• Line Units• Timing Functions• Mux. Controller and Communications functions
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
S3 0
1 2
M L
TU
1A
S3 0
2 2
M L
TU
1B
S3 0
3 2
M L
TU
1C
S3 0
4 G
eneric T
rib 1
PS
U/L
TU
S3 0
5 2
M L
TU
2A
S3 0
6 2
M L
TU
2B
S3 0
7 2
M L
TU
2C
S3 0
8 G
eneric T
rib 2
PS
U/L
TU
S3 0
9 2
M L
TU
3A
S3 1
0 2
M L
TU
3B
S3 1
1 2
M L
TU
3C
S3 1
2 G
eneric T
rib 3
PS
U/L
TU
S3 1
3 2
M L
TU
4A
S3 1
4 2
M L
TU
4B
S3 1
5 2
M L
TU
4C
S3 1
6 G
eneric T
rib 4
PS
U/L
TU
S3 1
7 G
eneric T
rib 5
PS
U/L
TU
S3 1
8 G
eneric T
rib 6
PS
U/L
TU
S3 1
9 G
eneric T
rib 7
PS
U/L
TU
S3 2
0 P
ow
er
& L
CT
LT
U
S3 2
1 P
ow
er
& L
CT
LT
U
1 11
1 2 3 1 2 3 1 2 3 1 2 3
S1_01 2
M T
rib 1
S1_02 G
eneric T
rib 1
S1_03 2
M T
rib 2
S1_04 G
eneric T
rib 2
S1_05 2
M P
rote
ction T
rib
S1_08 2
M T
rib 3
S1_09 G
eneric T
rib 3
S1_10 2
M T
rib 4
S1_11 G
eneric T
rib 4
S1_12 G
eneric T
rib 5
S1_13 G
eneric T
rib 6
S1_14 G
eneric T
rib 7
1
S1_06 T
raff
ic C
ore
B
S1_07 T
raff
ic C
ore
A /
CC
U
[bla
nk]
S1_15 C
om
ms/A
ux/A
ncill
iary
Unit
TribGroup
1
TribGroup
2
TribGroup
3
TribGroup
4
SMA 1/4EX Core/CCU ADM Unit, Core A (slot 1_7) SMA 1/4EX Core/CCU ADM Unit, Core A (slot 1_7) SMA 1/4EX Core/CCU ADM Unit, Core A (slot 1_7) SMA 1/4EX Core/CCU ADM Unit, Core A (slot 1_7)
17
Comprises :-
• Switch functions• Line Units• Timing Functions
S3 0
1 2
M L
TU
1A
S3 0
2 2
M L
TU
1B
S3 0
3 2
M L
TU
1C
S3 0
4 G
eneric T
rib 1
PS
U/L
TU
S3 0
5 2
M L
TU
2A
S3 0
6 2
M L
TU
2B
S3 0
7 2
M L
TU
2C
S3 0
8 G
eneric T
rib 2
PS
U/L
TU
S3 0
9 2
M L
TU
3A
S3 1
0 2
M L
TU
3B
S3 1
1 2
M L
TU
3C
S3 1
2 G
eneric T
rib 3
PS
U/L
TU
S3 1
3 2
M L
TU
4A
S3 1
4 2
M L
TU
4B
S3 1
5 2
M L
TU
4C
S3 1
6 G
eneric T
rib 4
PS
U/L
TU
S3 1
7 G
eneric T
rib 5
PS
U/L
TU
S3 1
8 G
eneric T
rib 6
PS
U/L
TU
S3 1
9 G
eneric T
rib 7
PS
U/L
TU
S3 2
0 P
ow
er
& L
CT
LT
U
S3 2
1 P
ow
er
& L
CT
LT
U
1 11
1 2 3 1 2 3 1 2 3 1 2 3
S1_01 2
M T
rib 1
S1_02 G
eneric T
rib 1
S1_03 2
M T
rib 2
S1_04 G
eneric T
rib 2
S1_05 2
M P
rote
ction T
rib
S1_08 2
M T
rib 3
S1_09 G
eneric T
rib 3
S1_10 2
M T
rib 4
S1_11 G
eneric T
rib 4
S1_12 G
eneric T
rib 5
S1_13 G
eneric T
rib 6
S1_14 G
eneric T
rib 7
1
S1_06 T
raff
ic C
ore
B
S1_07 T
raff
ic C
ore
A /
CC
U
[bla
nk]
S1_15 C
om
ms/A
ux/A
ncillia
ry
Unit
TribGroup
1
TribGroup
2
TribGroup
3
TribGroup
4
SMA 1/4EX Core Protection ADM Unit, Core B (Slot 1_6)SMA 1/4EX Core Protection ADM Unit, Core B (Slot 1_6)SMA 1/4EX Core Protection ADM Unit, Core B (Slot 1_6)SMA 1/4EX Core Protection ADM Unit, Core B (Slot 1_6)
18
S3 0
1 2
M L
TU
1A
S3 0
2 2
M L
TU
1B
S3 0
3 2
M L
TU
1C
S3 0
4 G
eneric T
rib 1
PS
U/L
TU
S3 0
5 2
M L
TU
2A
S3 0
6 2
M L
TU
2B
S3 0
7 2
M L
TU
2C
S3 0
8 G
eneric T
rib 2
PS
U/L
TU
S3 0
9 2
M L
TU
3A
S3 1
0 2
M L
TU
3B
S3 1
1 2
M L
TU
3C
S3 1
2 G
eneric T
rib 3
PS
U/L
TU
S3 1
3 2
M L
TU
4A
S3 1
4 2
M L
TU
4B
S3 1
5 2
M L
TU
4C
S3 1
6 G
eneric T
rib 4
PS
U/L
TU
S3 1
7 G
eneric T
rib 5
PS
U/L
TU
S3 1
8 G
eneric T
rib 6
PS
U/L
TU
S3 1
9 G
eneric T
rib 7
PS
U/L
TU
S3 2
0 P
ow
er
& L
CT
LT
U
S3 2
1 P
ow
er
& L
CT
LT
U
1 11
1 2 3 1 2 3 1 2 3 1 2 3
S1_01 2
M T
rib 1
S1_02 G
eneric T
rib 1
S1_03 2
M T
rib 2
S1_04 G
eneric T
rib 2
S1_05 2
M P
rote
ction T
rib
S1_08 2
M T
rib 3
S1_09 G
eneric T
rib 3
S1_10 2
M T
rib 4
S1_11 G
eneric T
rib 4
S1_12 G
eneric T
rib 5
S1_13 G
eneric T
rib 6
S1_14 G
eneric T
rib 7
1
S1_06 T
raff
ic C
ore
B
S1_07 T
raff
ic C
ore
A /
CC
U
[bla
nk]
S1_15 C
om
ms/A
ux/A
ncill
iary
Unit
TribGroup
1
TribGroup
2
TribGroup
3
TribGroup
4
63 Port 2MBit/s Trib (protection)63 Port 2MBit/s Trib (protection)63 Port 2MBit/s Trib (protection)63 Port 2MBit/s Trib (protection)
19
S3 0
1 2
M L
TU
1A
S3 0
2 2
M L
TU
1B
S3 0
3 2
M L
TU
1C
S3 0
4 G
eneric T
rib 1
PS
U/L
TU
S3 0
5 2
M L
TU
2A
S3 0
6 2
M L
TU
2B
S3 0
7 2
M L
TU
2C
S3 0
8 G
eneric T
rib 2
PS
U/L
TU
S3 0
9 2
M L
TU
3A
S3 1
0 2
M L
TU
3B
S3 1
1 2
M L
TU
3C
S3 1
2 G
eneric T
rib 3
PS
U/L
TU
S3 1
3 2
M L
TU
4A
S3 1
4 2
M L
TU
4B
S3 1
5 2
M L
TU
4C
S3 1
6 G
eneric T
rib 4
PS
U/L
TU
S3 1
7 G
eneric T
rib 5
PS
U/L
TU
S3 1
8 G
eneric T
rib 6
PS
U/L
TU
S3 1
9 G
eneric T
rib 7
PS
U/L
TU
S3 2
0 P
ow
er
& L
CT
LT
U
S3 2
1 P
ow
er
& L
CT
LT
U
1 11
1 2 3 1 2 3 1 2 3 1 2 3
S1_01 2
M T
rib 1
S1_02 G
eneric T
rib 1
S1_03 2
M T
rib 2
S1_04 G
eneric T
rib 2
S1_05 2
M P
rote
ction T
rib
S1_08 2
M T
rib 3
S1_09 G
eneric T
rib 3
S1_10 2
M T
rib 4
S1_11 G
eneric T
rib 4
S1_12 G
eneric T
rib 5
S1_13 G
eneric T
rib 6
S1_14 G
eneric T
rib 7
11 1 1 1
S1_06 T
raff
ic C
ore
B
S1_07 T
raff
ic C
ore
A /
CC
U
[bla
nk]
S1_15 C
om
ms/A
ux/A
ncilliary
Unit
TribGroup
1
TribGroup
2
TribGroup
3
TribGroup
4
2Mb/s Trib Numbering (Balanced)2Mb/s Trib Numbering (Balanced)2Mb/s Trib Numbering (Balanced)2Mb/s Trib Numbering (Balanced)
20
Wire a (-) Wire b (+) Wire a (-) Wire b (+)14 13 1 WHITE BLUE12 11 2 WHITE ORANGE10 9 3 WHITE GREEN8 7 4 WHITE BROWN6 5 5 WHITE GREY4 3 6 RED BLUE2 1 7 RED ORANGE
29 28 8 RED GREEN27 26 9 WHITE BLUE25 24 10 WHITE ORANGE23 22 11 WHITE GREEN21 20 12 WHITE BROWN19 18 13 WHITE GREY17 16 14 RED BLUE44 43 15 RED ORANGE42 41 16 RED GREEN40 39 17 WHITE BLUE38 37 18 WHITE ORANGE36 35 19 WHITE GREEN34 33 20 WHITE BROWN32 31 21 WHITE GREYn/a n/a n/a RED BLUEn/a n/a n/a RED ORANGEn/a n/a n/a RED GREENn/a n/a n/a WHITE BLUEn/a n/a n/a WHITE ORANGEn/a n/a n/a WHITE GREENn/a n/a n/a WHITE BROWNn/a n/a n/a WHITE GREYn/a n/a n/a RED BLUEn/a n/a n/a RED ORANGEn/a n/a n/a RED GREEN
Connector(PIN)Pair Layer
Colour Code
BLUE
ORANGE
GREEN
BROWN
Line Termination Unit (2 Mbs – Balance)Line Termination Unit (2 Mbs – Balance)Line Termination Unit (2 Mbs – Balance)Line Termination Unit (2 Mbs – Balance)
21
S3
01 2
M L
TU
1A
S3
02 2
M L
TU
1B
S3
03 2
M L
TU
1C
S3
04 G
ener
ic T
rib 1
PS
U/L
TU
S3
05 2
M L
TU
2A
S3
06 2
M L
TU
2B
S3
07 2
M L
TU
2C
S3
08 G
ener
ic T
rib 2
PS
U/L
TU
S3
09 2
M L
TU
3A
S3
10 2
M L
TU
3B
S3
11 2
M L
TU
3C
S3
12 G
ener
ic T
rib 3
PS
U/L
TU
S3
13 2
M L
TU
4A
S3
14 2
M L
TU
4B
S3
15 2
M L
TU
4C
S3
16 G
ener
ic T
rib 4
PS
U/L
TU
S3
17 G
ener
ic T
rib 5
PS
U/L
TU
S3
18 G
ener
ic T
rib 6
PS
U/L
TU
S3
19 G
ener
ic T
rib 7
PS
U/L
TU
S3
20 P
ower
& L
CT
LT
U
S3
21 P
ower
& L
CT
LT
U
1 11
S1_
01 2
M T
rib 1
S1_
02 G
ener
ic T
rib 1
S1_
03 2
M T
rib 2
S1_
04 G
ener
ic T
rib 2
S1_
05 2
M P
rote
ctio
n T
rib
S1_
08 2
M T
rib 3
S1_
09 G
ener
ic T
rib 3
S1_
10 2
M T
rib 4
S1_
11 G
ener
ic T
rib 4
S1_
12 G
ener
ic T
rib 5
S1_
13 G
ener
ic T
rib 6
S1_
14 G
ener
ic T
rib 7
1
S1_
06 T
raff
ic C
ore
B
S1_
07 T
raff
ic C
ore
A /
CC
U
[bla
nk]
S1_
15 C
omm
s/A
ux/A
ncill
iary
Uni
t
TribGroup
1
TribGroup
2
TribGroup
3
TribGroup
4
2Mb/s Trib Numbering (Unbalanced)2Mb/s Trib Numbering (Unbalanced)2Mb/s Trib Numbering (Unbalanced)2Mb/s Trib Numbering (Unbalanced)
22
Line Termination Unit (Clock IN/OUT)Line Termination Unit (Clock IN/OUT)Line Termination Unit (Clock IN/OUT)Line Termination Unit (Clock IN/OUT)
23
Line Termination Unit (Rack Alarm Unit)Line Termination Unit (Rack Alarm Unit)Line Termination Unit (Rack Alarm Unit)Line Termination Unit (Rack Alarm Unit)
Alarm from OMS 1200 to Rack Alarm Unit
Pin No Signal Name Pin No Signal Name
1 GND 1 + Vs Service Voltage4 EL 4 Rack Red LED 5 A 3 Rack Yellow LED8 +S 9 Mechanical GND9 ZA(LE) 6 - Vs Service Voltage
D-Type 15 Pin (Female), OMS 1200 D-Type 9 Pin (Male), RLDU
OMS BW7R SDH Rack Alarm Unit
+S
+S
+S
a
el
unused
Za(A)
GND
-S
-S
-S
b
unused
Za(B)
Za(LE)
24
Line Terminations Unit (Alarm PIN)Line Terminations Unit (Alarm PIN)Line Terminations Unit (Alarm PIN)Line Terminations Unit (Alarm PIN)
Pin No Signal Name
1 User Out 3A2 User Out 3B3 GND4 User Out 1A5 User Out 1B6 User Out 4A7 User Out 4B8 User Out 2A9 User Out 2B
D-Type 9 Pin (Female), User Output (SK6)
Pin No Signal Name
1 No Connection2 User input 13 User input 24 User input 35 User input 46 User input 57 User input 68 No Connection9 GND
10 GND11 GND12 GND13 GND14 GND15 No Connection
D-Type 15 Pin (Female), OMS 1200 (User input SK7)
25
The power/LCT LTU provides connection to the DC power supply via a single 3-pin-D type connector.
An RJ45 port provides local access to the equipment via a PC.
Two power/LCT LTU can be fitted in slots 3_20 and Slots 3_21 for protection of the DC power supply.
Only the power/LCT LTU at slots 3_21 provides LCT access for the equipment.
LCT 'F' I/F(RJ-45)
POSITIVE (Red)
EARTH
NEGATIVE (Blue)
Power and LCT LTUPower and LCT LTUPower and LCT LTUPower and LCT LTU
26
SMA 1/4 EX
SFP
Copyright - refer to the Title Page www.marconi.com
Small Form-Factor PluggableSmall Form-Factor PluggableSmall Form-Factor PluggableSmall Form-Factor Pluggable
27
SFP InterfacesSFP InterfacesSFP InterfacesSFP Interfaces
Increased flexibility – interfaces plug into sockets on Core cards, Quad flexible Tributary cards and Ethernet Tributary cards
Rugged solution for simple and reliable installation
Reduced installation time
Standardisation on LC connectors
Increased flexibility, same SFPs used in other Marconi Next Generation products, OMS16-XX and PacketSpan - reduced inventory cost
In-service upgrade without removing card in the appropriate core, simply plug in module
In-service upgrade STM-1 to STM-4 in SMA1/4UC and SMA1/4EX, STM-4 to STM-16 in SMA16UC and SMA16EX
SFPs, hot pluggable - convenient, easy-fit, consumer-type, latching module clips into on-card socket
28
SFP InterfacesSFP InterfacesSFP InterfacesSFP Interfaces
SFP Module Type SMA1/4UC/EX Core Line I/F
SMA16UC/EX Core Line I/F
Multi-rate SDH
Tributary 1.0/2.3COAX STM-1 X X STM-1 S1.1 X X STM-1 L1.1 X X STM-1 L1.2 X X STM-4 S/I4.1 X X X STM-4 L4.1 X X X STM-4 L4.2 X X X STM-16 S-16.1 X STM-16 L-16.1 X STM-16L-16.2 X
SFP Types applicable to each card
29
SFP InterfacesSFP InterfacesSFP InterfacesSFP Interfaces
Code No Designation DescriptionSU 66AA S1.1 STM-1 Optical Module (LC)
SU 66AB L1.1 STM-1 Optical Module (LC)
SU 66AC L1.2 STM-1 Optical Module (LC)
SU 67AA S4.1 STM-4 Optical Module (LC)
SU 67AB L4.1 STM-4 Optical Module (LC)
SU 67AC L4.2 STM-4 Optical Module (LC)
SU 65AA EL STM-1 Electrical Module
30
Core Card AAmber – In TrafficAmber – In TrafficRed - Micro/Comms AlarmRed - Micro/Comms AlarmRed - Traffic failureRed - Traffic failure
Amber – In TrafficAmber – In Traffic
Red - Traffic failureRed - Traffic failure
Amber - Comms in useAmber - Comms in useAmber - ProcessingAmber - ProcessingAmber - SMC Data Base InvalidAmber - SMC Data Base Invalid
LW Amber Test LEDLW Amber Test LEDLW Test/Restart ButtonLW Test/Restart ButtonLE Amber Test LEDLE Amber Test LEDLE Test/Restart ButtonLE Test/Restart Button
LW Amber Test LEDLW Amber Test LEDLW Test/Restart ButtonLW Test/Restart ButtonLE Amber Test LEDLE Amber Test LEDLE Test/Restart ButtonLE Test/Restart Button
Core Card B