2
MOUNTING INTERFACE OPERATING PRINCIPLE MODULAR VERSION NFPA D03 ISO 4401-03 P Q max max 3000 PSI 15 GPM 210 bar 57 I/min PERFORMANCES HYDRAULIC SYMBOLS (measured with mineral oil of viscosity 36cSt at 120°F [50°C]) Maximum operating pressure PSI [bar] GPM [l/min] 3000 [210] 15 [57] 400-1500 PSI [28-105 bar] 1000-2500 PSI [70-175 bar] 5 drops per min 3:1 4.5:1 25 PSI [1.7 bar] >85% of setting No. of CCW turns from Min. to Max. settting 3.75 F˚ [C˚] -4 to 140 [-20 to +60] F˚ [C˚] -4 to 176 [-20 to +80] Max Flow rate Pressure adjustment range: Code 150 Code 300 Pilot ratio: Code 150 Code 300 Check Valve cracking pressure Adjustment Range: Reseat Ambient temperature range Fluid temperature range cST 100 - 400 cST 25 Lbs [kg] 1.67 [0.76] 1.14 [0.52] Fluid viscosity range According to ISO 4406: 1999 Class 19/17/14 Fluid contamination degree Recommended viscosity Mass: P03MSV-CC P03MSV-CA, CB Max valve leakage at reseat P03MSV-CC/CA/CB PILOT OPERATED COUNTERBALANCE VALVE The P03MSV-C counterbalance valves with pilot assist are designed to control an overrunning load or hold a load in position by maintaining a back pressure on the outlet of the cylinder. An integral check valve allows for free flow in the reverse direction. Valve conforms to NFPA D03/ISO 4401-03 standard for valve mounting interface. This valve can also be used as a brake valve in hydraulic motor circuits for a controlled deceleration. Counterbalance valves should be set at least 130% of maximum pressure due to load. Backpressure adds to the valve setting by (1.0 + pilot ratio) times the backpressure. Reverse flow will open the check at about 25 psi [1.7 bar]. 3.75 turns of adjustment CCW from Min. to Max. pressure setting. [12.7] .500 [21.5] .846 [30.2] 1.190 [40.5] 1.594 [0.75] .03 [5.1] .20 [15.5] .610 [25.9] 1.02 [31] 1.220 [31.75] 1.250 [7.5] .295(max) [4] .16 [33] 1.30 [M5 X0.8-6H] #10-24UNC-2B DIMENSIONS: INCHES [mm] NFPA D03 ISO 4401-03-02-0-05 P B A T P03MSV-CC P B T B1 P1 T1 A1 A P1 B1 P T1 A T A1 B P03MSV-CB G P03MSV-CA A B1 P B A1 T P1 T1 G

19-08-12 P03MSV-CC CA CB RL-PROOF...Valve conforms to NFPA D03/ISO 4401-03 standard for valve mounting interface. • This valve can also be used as a brake valve in hydraulic motor

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 19-08-12 P03MSV-CC CA CB RL-PROOF...Valve conforms to NFPA D03/ISO 4401-03 standard for valve mounting interface. • This valve can also be used as a brake valve in hydraulic motor

MOUNTING INTERFACE OPERATING PRINCIPLE

MODULAR VERSIONNFPA D03 ISO 4401-03

P Q

maxmax

3000 PSI15 GPM

210 bar 57 I/min

PERFORMANCES HYDRAULIC SYMBOLS(measured with mineral oil of viscosity 36cSt at 120°F [50°C])

Maximum operating pressure PSI [bar]

GPM [l/min]

3000 [210]

15 [57]

400-1500 PSI [28-105 bar]1000-2500 PSI [70-175 bar]

5 drops per min

3:14.5:1

25 PSI [1.7 bar]

>85% of setting

No. of CCW turns from Min. to Max. settting

3.75

F˚ [C˚] -4 to 140 [-20 to +60]

F˚ [C˚] -4 to 176 [-20 to +80]

Max Flow rate

Pressure adjustment range: Code 150Code 300

Pilot ratio: Code 150Code 300

Check Valve cracking pressure

Adjustment Range:

Reseat

Ambient temperature range

Fluid temperature range

cST 100 - 400

cST 25Lbs [kg] 1.67 [0.76]

1.14 [0.52]

Fluid viscosity range

According to ISO 4406: 1999 Class 19/17/14Fluid contamination degree Recommended viscosity

Mass: P03MSV-CC P03MSV-CA, CB

Max valve leakage at reseat

P03MSV-CC/CA/CBPILOT OPERATED

COUNTERBALANCE VALVE

• The P03MSV-C counterbalance valves with pilot assist are designed to control an overrunning load or hold a load in position by maintaining a back pressure on the outlet of the cylinder. An integral check valve allows for free flow in the reverse direction. Valve conforms to NFPA D03/ISO 4401-03 standard for valve mounting interface.

• This valve can also be used as a brake valve in hydraulic motor circuits for a controlled deceleration.

• Counterbalance valves should be set at least 130% of maximum pressure due to load.

• Backpressure adds to the valve setting by (1.0 + pilot ratio) times the backpressure.

• Reverse flow will open the check at about 25 psi [1.7 bar].

• 3.75 turns of adjustment CCW from Min. to Max. pressure setting.

[12.7].500

[21.5].846

[30.2]1.190

[40.5]1.594

[0.75].03

[5.1].20

[15.5].610[25.9]

1.02 [31]

1.220 [31.75]1.250

[7.5].295(max)

[4].16

[33]1.30

[M5 X0.8-6H]#10-24UNC-2B

DIMENSIONS: INCHES [mm]NFPA D03ISO 4401-03-02-0-05

P

BA

T

P03MSV-CC

P BT

B1P1 T1A1

A

G

P1 B1

P

T1

A T

A1

B

P03MSV-CBG

P03MSV-CC

P BT

B1P1 T1A1

A

P03MSV-CA

A

B1

P B

A1

T

P1 T1

G

Page 2: 19-08-12 P03MSV-CC CA CB RL-PROOF...Valve conforms to NFPA D03/ISO 4401-03 standard for valve mounting interface. • This valve can also be used as a brake valve in hydraulic motor

1

2

Countersunk hex adjustment screw: 5/32” [4 mm] allen wrench

Rotate counterclockwise to increase pressure

3 Qty. 4 O-rings - size AS568-012 (.364 ID x .070 CS) 90 Shore

4 1/4 NPTF Gauge Port

Locking nut: 9/16” wrench

1 • IDENTIFICATION CODE

Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code A). For fluids HFDR type (phosphate esters) use FPM seals (code G). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical department. Using fluids at temperatures higher than 176ºF [80ºC] causes a faster degradation of the fluid and of the seals characteristics.

The fluid must be preserved in its physical and chemical characteristics.

FORM NO. 1025244 REV 08-2019 © CONTINENTAL HYDRAULICS INC. ALL RIGHTS RESERVED.PRODUCT SPECIFICATIONS AND PERFORMANCE SUBJECT TO CHANGE WITHOUT NOTICE.

4895 12TH AVENUE EAST • SHAKOPEE, MN 55379

952.895.6400 • WWW.CONTINENTALHYDRAULICS.COM

2 • HYDRAULIC FLUIDS

3 • OVERALL AND MOUNTING DIMENSIONS

C A C P03MSV - - - -

D03 INTERFACE

VALVE SERIES

CODE NFPA SIZE

03

CONTROL PORT

CODE PORT

A A

B B

C A & B

MECHANICAL

CODE DESCRIPTION

OMIT STD W/ SOC HEAD ADJ.

MATERIAL SELECTION

CODE DESCRIPTION

A ALUMINUM

DESIGN LETTERVALVE TYPE

PRESSURE CONTROL

VALVE FUNCTION

CODE FUNCTION AVAIL WITH PORTS

C COUNTERBALANCE A, B, A & B

CODE

150

300

PSI

400-1500

1000-2500

BAR

28-105

70-175

PILOT RATIO

3:1

4.5:1

PRESSURE ADJUSTMENT RANGE

SEAL MATERIAL

CODE DESC.

A BUNA-N

G VITON

DIMENSIONS IN INCHES [mm]

16.63

39.91.57 1

2 3

41.21.62

125.24.93

157.26.19

32

1.26

189.27.45

6.9.27

44.41.75

22.1.87

92.73.65

125.24.93

15.7.62

39.91.57

42.71.68 4

6.9.27

39.91.57

127.85.03

15.7.62

95.33.75

4

P03MSV-CCP03MSV-CB

P03MSV-CA

P03MSV-CA

A

B1

P B

A1

T

P1 T1 P1 B1

P

T1

A T

A1

B

P03MSV-CB

G

G