11
BASEBALL DIAMOND PARKING RATHGAR AVENUE BERESFORD AVENUE LILAC STREET ARGUE STREET AREA OF WORK FIRE STATION #13 KEY PLAN SCALE: 1:500 1 A0.0 ARCHITECT: 1x1 ARCHITECTURE INC 120 FORT STREET, SUITE 103 WINNIPEG, MANITOBA, R3C 1C7 TEL: (204) 318-2010 FIRE STATION NO. 13 INTERIOR RENOVATION BID OPPORTUNITY 280-2020 799 LILAC STREET, WINNIPEG, MANITOBA ISSUED FOR CONSTRUCTION JUNE 25, 2020 CONSULTANT TEAM ABBREVATIONS MAXIMUM PLATE PLYWOOD LOCATION MASONRY MISCELLANEOUS OVERHEAD ON CENTER MECHANICAL OUTSIDE DIAMETER OPENING OPEN WEB STEEL JOIST OUTSIDE FACE METAL NOT IN CONTRACT MINIMUM LONG INSULATION PRESSED STEEL PREFINISHED PANEL PAINTED, PAINT REINFORCED REINFORCED CONCRETE STEEL STAINLESS STEEL SPECIFIED SIMILAR ROOM PLASTIC LAMINATE SIM EXTERIOR EXT FIRE HOSE CABINET F.H.C ST, STL SPEC'D S.S CONCRETE BLOCK CAST IN PLACE COMPLETE WITH CENTER LINE CONTROL JOINT EQUIPMENT ELECTRICAL C/W EPOX ELEC EQUIP ELEV DWG, DRWG EQ EXP EA DN DTL D ELEVATION EQUAL EXPOSED EPOXY DOWN DRAWING EACH DETAIL DEEP CONC COL C.I.P CJ CL C.B COLUMN CONCRETE REINF RM R/CONC PTD, PT PREFIN PS O.H PL PLYW P.LAM PNL O.W.S.J OPNG O.C O/F O.D N.I.C MTL BOTH SIDES ABOVE FLOOR BTWN BOT, BTM BLDG ANOD ALUM A/FL B.S BM ANODIZED BOTTOM BETWEEN BEAM BUILDING ALUMINUM MAS MISC MECH MIN MAX L LOC INSUL WATERPROOFED MEMBRANE SUSPENDED TOP OF UNDER SIDE STRUCTURAL SURFACE MOUNTED UNDER FLOOR TYPICAL STORAGE WIDE WITH VESTIBULE VAPOUR BARRIER VEHICLE VERTICAL GYPSUM WALL BOARD GRID LINE HOLLOW METAL GALVANIZED GENERAL CONTRACTOR HEAVY DUTY HORIZONTAL HOLLOW STEEL SECTION HYDRAULIC INSIDE DIAMETER INSIDE FACE GWB HYDR HOR, HORIZ INT I/F I.D HT HSS HR H.M H.D H INTERIOR HEIGHT HOUR HIGH G.L GALV FLR, FL G.C GA FIN GAUGE FINISH FLOOR W/ W.MEM VERT VEST W VEH V.B SURF MTD TYP U/S U/F T.O. STO, STOR SUSP STRUC SLOPE SLP SHOWER SHWR HAZARDOUS WASTE H.W GALVALUME GLUM LIGHT WEIGHT L.W CENTER POINT C.P C.L.F CHAIN LINK FENCE THICK / THICKNESS TH UNDER GROUND U/G TOP OF CONCRETE T.O.C. WEEPING TILE W.T. FLOOR DRAIN FD ROUGH OPENING R.O. ROOF DRAIN R.D. MASONRY OPENING M.O. MIRROR MR INTERIOR WALL TYPES DOOR NUMBER ROOM NAME & NUMBER STRUCTURAL GRID WALL SECTION DRAWING TITLE & REFERENCE KEY NOTE BUILDING SECTION SECTION DETAIL NORTH ARROW SYMBOLS INTERIOR ELEVATION TITLE Scale = 1: # A#.# 100 000 LOCATION D000 ELEVATION POINTS IN PLAN # # A#.# SIM. # A#.# CEILING HEIGHT A.F.F. GLAZING TYPE HR FIRE RATING # REVISION NUMBER EXTERIOR ELEVATION # A#.# LOCATION 100 000 BENCHMARK ELEVATION ROOM RM# NAME 1/A # A#.# EXTERIOR WALL TYPE D# A B D C W# W# SEPARATION WITH F.R.R. R W# G# FULL HEIGHT SEPARATION FH W# 0000 GENERAL DRAWING NOTES THE DRAWINGS SHALL NOT BE SCALED. FOLLOW GIVEN DIMENSIONS ONLY. THE CONTRACTOR SHALL SATISFY HIMSELF THAT ALL DIMENSIONS, ELEVATIONS, DATUMS, AND INFORMATION SHOWN ARE CORRECT. VERIFY ALL DIMENSIONS ON SITE. DIMENSIONS ARE AS FOLLOW UNLESS OTHERWISE NOTED: - FACE OF MASONRY WALLS - EXTERIOR FACE OF ALL INTERIOR WALLS PRIOR TO COMMENCEMENT OF WORK, REPORT ANY DISCREPANCIES TO THE CONTRACT ADMINISTRATOR. VARIATIONS AND MODIFICATIONS TO WORK SHOWN WILL NOT BE ALLOWED WITHOUT THE WRITTEN PERMISSION OF THE CONTRACT ADMINISTRATOR. ALL DIMENSIONS ARE IMPERIAL UNLESS OTHERWISE NOTED. NO REPRODUCTION OF THE DRAWINGS MAY BE MADE WITHOUT THE WRITTEN CONSENT OF THE CITY OF WINNIPEG AND ALL REPRODUCTION MUST BEAR THE NAME OF THE ARCHITECT. GENERAL CONTRACTOR SHALL NOTIFY THE CONTRACT ADMINISTRATOR OF ANY MECHANICAL AND ELECTRICAL APPARATUS APPEARANCE WHICH MAY VARY FROM THAT INDICATED IN THE CONTRACT DOCUMENTS. DRAWING LIST MECHANICAL EPP SIEPMAN ENGINEERING INC. ENGINEER: 136 MARKET AVE WINNIPEG, MANITOBA, R3B 3N2 TEL: (204) 453-1080 ELECTRICAL EPP SIEPMAN ENGINEERING INC. ENGINEER: 136 MARKET AVE WINNIPEG, MANITOBA, R3B 3N2 TEL: (204) 453-1080 PRIME CONSULTANT: MECHANICAL M2.1 FLOOR PLANS - MECHANICAL ELECTRICAL E0.1 ELECTRICAL SYMBOLS AND ABBREVIATIONS EL2.1 MAIN FLOOR - LIGHTING PLAN EP2.1 MAIN FLOOR - POWER PLAN E6.1 ELECTRICAL SCHEDULES ARCHITECTURAL A0.0 TITLE SHEET A1.0 FLOOR PLANS A1.1 REFLECTED CEILING PLANS A1.2 INTERIOR ELEVATIONS & MILLWORK DETAILS A1.3 FLOOR FINISH PLANS, INTERIOR ELEVATIONS & MILLWORK DETAILS A1.4 SCHEDULES & SPECIFICATIONS NOTE: THE SCOPE OF THE RENOVATION DOES NOT CHANGE THE USE, OCCUPANT LOAD, MAJOR OCCUPANCY CLASSIFICATION OR EXIT CONFIGURATION OF THE BUILDING. IN OUR PROFESSIONAL OPINION, LIFE SAFETY WILL NOT BE AFFECTED BY THIS MODERNIZATION AND INTERIOR ALTERATION.

19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

BASEBALLDIAMOND

PARKING

RATHGAR AVENUE

BERESFORD AVENUE

LILAC

STR

EET

ARGUE STREET

AREA OF WORK

FIRE STATION #13

KEY PLANSCALE: 1:500

1A0.0

ARCHITECT: 1x1 ARCHITECTURE INC120 FORT STREET, SUITE 103WINNIPEG, MANITOBA, R3C 1C7TEL: (204) 318-2010

FIRE STATION NO. 13INTERIOR RENOVATION

BID OPPORTUNITY 280-2020799 LILAC STREET, WINNIPEG, MANITOBA

ISSUED FOR CONSTRUCTION

JUNE 25, 2020

CONSULTANT TEAM

ABBREVATIONS

MAXIMUM

PLATE

PLYWOOD

LOCATIONMASONRY

MISCELLANEOUS

OVERHEAD

ON CENTER

MECHANICAL

OUTSIDE DIAMETER

OPENINGOPEN WEB STEEL JOIST

OUTSIDE FACE

METALNOT IN CONTRACT

MINIMUM

LONG

INSULATION

PRESSED STEELPREFINISHEDPANEL

PAINTED, PAINT

REINFORCED

REINFORCED CONCRETE

STEELSTAINLESS STEELSPECIFIED

SIMILAR

ROOM

PLASTIC LAMINATE

SIMEXTERIOREXT

FIRE HOSE CABINETF.H.C

ST, STL

SPEC'DS.S

CONCRETE BLOCK

CAST IN PLACE

COMPLETE WITH

CENTER LINE

CONTROL JOINT

EQUIPMENT

ELECTRICAL

C/W

EPOXELEC

EQUIP

ELEV

DWG, DRWG

EQ

EXP

EA

DNDTLD

ELEVATION

EQUAL

EXPOSED

EPOXY

DOWNDRAWINGEACH

DETAILDEEP

CONC

COL

C.I.P

CJ

CL

C.B

COLUMN

CONCRETE

REINFRM

R/CONCPTD, PT

PREFINPS

O.H

PL

PLYWP.LAM

PNL

O.W.S.JOPNG

O.C

O/FO.D

N.I.CMTL

BOTH SIDES

ABOVE FLOOR

BTWN

BOT, BTM

BLDGANODALUMA/FL

B.S

BM

ANODIZED

BOTTOM

BETWEEN

BEAMBUILDING

ALUMINUM MAS

MISC

MECHMIN

MAX

L

LOC

INSUL WATERPROOFED MEMBRANE

SUSPENDED

TOP OF

UNDER SIDE

STRUCTURALSURFACE MOUNTED

UNDER FLOORTYPICAL

STORAGE

WIDEWITH

VESTIBULE

VAPOUR BARRIERVEHICLEVERTICAL

GYPSUM WALL BOARDGRID LINE

HOLLOW METAL

GALVANIZED

GENERAL CONTRACTOR

HEAVY DUTY

HORIZONTAL

HOLLOW STEEL SECTIONHYDRAULICINSIDE DIAMETERINSIDE FACE

GWB

HYDR

HOR, HORIZ

INTI/FI.D

HT

HSSHR

H.M

H.DH

INTERIOR

HEIGHT

HOUR

HIGH

G.L

GALV

FLR, FL

G.C

GA

FIN

GAUGE

FINISHFLOOR

W/W.MEM

VERTVESTW

VEHV.B

SURF MTD

TYP

U/S

U/F

T.O.

STO, STOR

SUSP

STRUC

SLOPESLP

SHOWERSHWR

HAZARDOUS WASTEH.W

GALVALUMEGLUM

LIGHT WEIGHTL.W

CENTER POINTC.PC.L.F CHAIN LINK FENCE

THICK / THICKNESSTH

UNDER GROUNDU/G

TOP OF CONCRETET.O.C.

WEEPING TILEW.T.

FLOOR DRAINFD

ROUGH OPENINGR.O.

ROOF DRAINR.D.

MASONRY OPENINGM.O.MIRRORMR

INTERIOR WALL TYPES

DOOR NUMBER

ROOM NAME & NUMBER

STRUCTURAL GRID

WALL SECTION

DRAWING TITLE & REFERENCE

KEY NOTE

BUILDING SECTION

SECTION DETAIL

NORTH ARROW

SYMBOLS

INTERIOR ELEVATION

TITLEScale = 1:

#A#.#

100 000LOCATION

D000

ELEVATION POINTS IN PLAN

#

#A#.# SIM.

#A#.#

CEILING HEIGHT A.F.F.

GLAZING TYPE

HR FIRE RATING

# REVISION NUMBER

EXTERIOR ELEVATION#

A#.#

LOCATION100 000

BENCHMARK ELEVATION

ROOMRM#

NAME

1/A

#A#.#

EXTERIOR WALL TYPE

D#

A

BD

C

W#

W#

SEPARATION WITH F.R.R.R

W#

G#

FULL HEIGHT SEPARATIONFH

W#

0000

GENERAL DRAWING NOTESTHE DRAWINGS SHALL NOT BE SCALED. FOLLOW GIVEN DIMENSIONS ONLY.

THE CONTRACTOR SHALL SATISFY HIMSELF THAT ALL DIMENSIONS, ELEVATIONS, DATUMS, AND INFORMATION SHOWN ARE CORRECT. VERIFY ALL DIMENSIONS ON SITE. DIMENSIONS ARE AS FOLLOW UNLESS OTHERWISE NOTED: - FACE OF MASONRY WALLS - EXTERIOR FACE OF ALL INTERIOR WALLS

PRIOR TO COMMENCEMENT OF WORK, REPORT ANY DISCREPANCIES TO THE CONTRACT ADMINISTRATOR.

VARIATIONS AND MODIFICATIONS TO WORK SHOWN WILL NOT BE ALLOWED WITHOUT THE WRITTEN PERMISSION OF THE CONTRACT ADMINISTRATOR.

ALL DIMENSIONS ARE IMPERIAL UNLESS OTHERWISE NOTED.

NO REPRODUCTION OF THE DRAWINGS MAY BE MADE WITHOUT THE WRITTEN CONSENT OF THE CITY OF WINNIPEG AND ALL REPRODUCTION MUST BEAR THE NAME OF THE ARCHITECT.

GENERAL CONTRACTOR SHALL NOTIFY THE CONTRACT ADMINISTRATOR OF ANY MECHANICAL AND ELECTRICAL APPARATUS APPEARANCE WHICH MAY VARY FROM THAT INDICATED IN THE CONTRACT DOCUMENTS.

DRAWING LIST

MECHANICAL EPP SIEPMAN ENGINEERING INC.ENGINEER: 136 MARKET AVE

WINNIPEG, MANITOBA, R3B 3N2TEL: (204) 453-1080

ELECTRICAL EPP SIEPMAN ENGINEERING INC.ENGINEER: 136 MARKET AVE

WINNIPEG, MANITOBA, R3B 3N2TEL: (204) 453-1080

PRIME CONSULTANT:

MECHANICALM2.1 FLOOR PLANS - MECHANICAL

ELECTRICALE0.1 ELECTRICAL SYMBOLS AND ABBREVIATIONSEL2.1 MAIN FLOOR - LIGHTING PLANEP2.1 MAIN FLOOR - POWER PLANE6.1 ELECTRICAL SCHEDULES

ARCHITECTURALA0.0 TITLE SHEETA1.0 FLOOR PLANSA1.1 REFLECTED CEILING PLANSA1.2 INTERIOR ELEVATIONS & MILLWORK

DETAILSA1.3 FLOOR FINISH PLANS, INTERIOR

ELEVATIONS & MILLWORK DETAILSA1.4 SCHEDULES & SPECIFICATIONS

NOTE:THE SCOPE OF THE RENOVATION DOES NOT CHANGE THE USE, OCCUPANT LOAD, MAJOR OCCUPANCY CLASSIFICATION OR EXIT CONFIGURATION OF THE BUILDING. IN OUR PROFESSIONAL OPINION, LIFE SAFETY WILL NOT BE AFFECTED BY THIS MODERNIZATION AND INTERIOR ALTERATION.

Page 2: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

A1.019089A

FLOOR PLANS

WINNIPEG FPS FIRE STATION #13

NO.

0

DATE

25.06.2020

REVISION / ISSUANCE

-

1 DD.MM.YYYY -

2 DD.MM.YYYY -

3 DD.MM.YYYY -

4 DD.MM.YYYY -

Seal

Engineer

Project

Sheet Title

Project No.

Date

Sheet

25.06.2020

Architect

799 LILAC STREET

ISSUED FOR CONSTRUCTION

SPK30

1GR DW ST

MW

2222

18

18

3

3

3

3

3

3

3

18

18

3

3

3

18

18

18

ROOMG-04

PHONE

40

27

2020

29

5

6

FR

PO

P

FR

TD

7

7

9

10

35

32

12

13

14

15

3917

4

40

4040

21

21

21212121

21

21

3

40TYP.

19

22

23

24

CMCO

43

40

26

26

4

PH

PH

11

33

TYP.2

2

36

TT

8

4

4

30 34

34

38

WF

2

39

34

37

4

30

PH

FE

FE

FE

30

30

3016

16

4

4

3

18

3

18

29

25

2525

25

18

41TYP.

18

42

34

34

34

6

16

26

10

10

44 44 SPK

SPK

SPK

SPK

SPK

ROOMG-12

APPARATUS

VESTIBULEG-19

ROOMG-14

MECHANICAL

RECEPTIONG-02

ROOMG-23

CONTROL

OFFICEG-05

LIEUTENANT'S

OFFICEG-06

CAPTAIN'S

LOUNGEG-07

KITCHENG-08

CORRIDORG-03

CORRIDORG-13

WASHROOMG-16

MEN'S

SHOWERG-15

ROOMG-11

STATIONARY

WASHROOMG-09

UNISEX

ROOMG-17

LOCKER

DORMITORYG-18

VESTIBULEG-01

ROOMG-22

STORAGE

HOSE TOWERG-20

ROOMG-21

DRYING

UP

ROOMG-10

CLEANING

MAIN FLOOR PLAN - DEMOLITIONSCALE: 1/8" = 1'-0"

1A1.0

DEMOLITION PLAN NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

DEMOLISH ALL KITCHEN CABINETS & COUNTERS. G.C. TO CONFIRM IF OWNER TO RETAIN EXISTING APPLIANCES. REFER TO ELECT. & MECH.

REMOVAL OF EXISTING FURNITURE/EQUIPMENT FOR NEW FLOORING INSTALLATION TO BE COMPLETED BY OTHERS. FURNITURE TO BE RETURNED TO CONTRACT ADMINISTRATOR.

DEMOLISH EXISTING FLOORING & RUBBER BASEBOARD. PREPARE CONCRETE FLOOR FOR NEW FLOORING.

PATCH & REPAIR ABANDONED ELECTRICAL THROUGHOUT. IN DORM G-18, LOWER EXISTING JUNCTION BOXES/RECEPTACLES FOR EXISTING GYM EQUIPMENT AND PROVIDE NEW FACE PLATES. REFER TO ELECT.

DEMOLISH EXISTING WALL MOUNTED COUNTER. PATCH & MAKE GOOD & PAINT ALL ADJACENT SURFACES.

REMOVE EXISTING PHONE. REFER TO ELECTRICAL.

EXISTING FRIDGE TO BE REMOVED & RELOCATED FOR FLOORING INSTALLATION. REFER TO INTERIOR ELEVATIONS AND RENOVATION PLAN.

EXISTING HAND SANITIZER TO REMAIN. PROTECT DURING CONSTRUCTION.

REMOVE & RELOCATE EXISTING POPCORN MACHINE

REMOVE EXISTING SHELVING UNIT & RETURN TO OWNER.

DEMOLISH EXISTING HOOD & DUCT ABOVE FLAT GRILLE. PATCH & REPAIR DRYWALL. REFER TO MECH. RETURN FLAT GRILLE TO OWNER.

DEMOLISH JANITOR SINK, REFER TO MECHANICAL. PATCH & MAKE GOOD ALL SURFACES INCLUDING FLOORING.

DEMOLISH URINAL, REFER TO MECHANICAL. PATCH & MAKE GOOD ALL SURFACES.

DEMOLISH EXISTING SHELF & WALL SUPPORTS. PATCH & MAKE GOOD ALL ADJACENT SURFACES, TYP.

DEMOLISH EXISTING WALL HOOKS. PATCH & MAKE GOOD ALL ADJACENT SURFACES, TYP.

EXISTING FAUCET TO BE DEMOLISHED - TYPICAL. REFER TO MECH.

GENERAL NOTES:

THESE DRAWINGS SHALL NOT BE SCALED.

THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY ONESELF ALL DIMENSIONS, DATUM, AN DETAILED INFORMATION SHOWN ARE CORRECT.

THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGS FOR DUCT, PIPE & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS.

ALL OPENINGS THROUGH FIRE ASSEMBLIES ARE TO BE FIRESTOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER.

ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITH MANUFACTURER'S SPECIFICATIONS & APPLICABLE CODES.

THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTING CONSTRUCTION AFFECTED BY DEMOLITION AND THE REMOVAL OF ALL ITEMS FORMING PART OF THE RENOVATION WORK.

WHERE NEW FLOORING AND BASE IS TO BE INSTALLED IN EXISTING AREAS (REFER TO FLOOR PLAN AND ROOM SCHEDULE) THE EXISTING FLOORING SURFACE AND BASE MUST BE REMOVED, UNLESS OTHERWISE NOTED. ALL FLOOR SURFACES SHALL BE PREPARED IN ACOORDANCE TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF NEW FLOOR.

WHERE PAINTING OF EXISTING WALLS & CEILINGS IS INDICATED ON THE ROOM SCHEDULE, THESE WALLS MUST BE CLEANED OF ANY EXISTING WALL COVERING, PATCHED & PREPARED TO ACCEPT NEW PAINT, UNLESS OTHERWISE NOTED.

ALL EXISTING FURNITURE, EQUIPMENT (INCLUDING GYM EQUIPMENT), AND WALL MOUNTED ITEMS/ ARTWORK/ MAPS/ EXIT PLANS ARE TO BE REMOVED AND REINSTALLED BY THE CITY OF WINNIPEG'S MOVERS (TO BE STORED IN THE APPARATUS ROOM OR A STORAGE CONTAINER AS REQ'D).

EMERGENCY LIGHTING TO BE REPLACED, REFER TO ELECTRICAL FOR SCOPE OF WORK.

ALL MISCELLANEOUS FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED FOR FLOORING INSTALLATION.

ALL MECHANICAL WALL VENTS/GRILLES TO BE REMOVED & REINSTALLED FOR PAINTING.

ALL EXISTING DOORS ARE TO BE CUT DOWN OR ADJUSTED AS REQUIRED TO ACCOMMODATE NEW FLOORING THICKNESS. PATCH & MAKE GOOD ALL DOORS.

ALL FIRE EXTINGUISHERS TO BE REMOVED AND REINSTALLED FOR PAINTING.

WARNING:ASBESTOS MAY BE PRESENT BEHIND WALLS CEILING SPACE & FLOORS. IF ASBESTOS OR ANY HAZARDOUS MATERIAL IS FOUND STOP WORK IMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS PH: 204-986-2351.

SPK

SPK

SPK

SPK

SPK

ROOMG-12

APPARATUS

VESTIBULEG-19

ROOMG-14

MECHANICAL

RECEPTIONG-02

ROOMG-23

CONTROL

OFFICEG-05

LIEUTENANT'S

OFFICEG-06

CAPTAIN'S

LOUNGEG-07

KITCHENG-08

CORRIDORG-03

CORRIDORG-13

WASHROOMG-16

MEN'S

SHOWERG-15

ROOMG-11

STATIONARY

WASHROOMG-09

UNISEX

ROOMG-17

LOCKER

DORMITORYG-18

VESTIBULEG-01

ROOMG-22

STORAGE

HOSE TOWERG-20

ROOMG-21

DRYING

UP

ROOMG-10

CLEANING

11

A1.3

21

34

2222

2

2

2

2

W1

W2

W3

W4

W5W5W5W5

W5

21

21

21

21

21

40

21

16

21

21

21

37

31

5

23

6

3

DWMW

PO

P

FR

A1.2 5

W1

A1.2

6A1.27

4'-11"

7

38

38

44

20 3845

A1.3

3

24

6

TD

13

14

14

14

14

14

14

14

21

21

4

4

28 28

33

3333

3318

1919

35

25

25

25

25

12

CMCO

WADR

29

29

8

FR

13

17

WF

CG

CG 30

30

30 30

36

W1

17

11 CG

CG

A1.2

8

A1.2 9

22

14

10

43

FE

FE

DG05

15

FE

11

26

39

39

11

40

41

41

42±17'-6 1/2"

13

A1.3

32

9

23

5'-0

"5'

-0"

3'-6"

4646

4747

MAIN FLOOR PLAN - RENOVATIONSCALE: 1/8" = 1'-0"

3A1.0

SPK

SPK

SHOWER

HOSE TOWERG-20

DN

W5DORMITORY

M-01

RESCUEM-04

WATER

STAIRHALLM-03

W/CM-02

1TYP.

11 TYP. TYP.221

21

252533

2719

1414

14

FE

39

3422

MEZZANINE RENOVATION PLANSCALE: 1/8" = 1'-0"

4A1.0

RENOVATION PLAN NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

PATCH & PAINT EXISTING GWB IN WATER RESCUE ROOM, TYP.

PROVIDE NEW BLINDS AT ALL EXTERIOR WINDOWS, TYP. REFER TO WINDOW SCHEDULE AND SPECS.

INSTALL NEW WALL MOUNTED BATHROOM SHELF - REFER TO SPECIFICATIONS.

PAINT EXISTING METAL DOOR AND FRAME. PROVIDE KICKPLATE ON PUSH SIDE OF DOOR - REFER TO SPECS.

NEW DINING TABLES - REFER TO DETAILS & SPECIFICATIONS

EXISTING RECESSED FLOOR MAT TO REMAIN

RELOCATE EXISTING FRIDGE

EXISTING TOWEL BAR TO REMAIN. PROTECT DURING CONSTRUCTION.

NEW KITCHEN FAUCET - REFER TO MECH & SPECS

NEW VENT HOOD ABOVE - REFER TO MECH & INTERIOR ELEVATIONS

NEW ROOM DIVIDER PANELS - REFER TO SPECIFICATIONS. FINAL ROOM LAYOUT TO BE DETERMINED BY OWNER.

EXISTING TELEPHONE TO REMAIN

EXISTING MONITOR SCREEN C/W NEW ADJUSTABLE MONITOR ARM. CONTRACTOR TO SUPPLY AND INSTALL NEW ARM W/ EXISTING SCREEN. REFER TO SPEC.

PAINT EXISTING METAL DOOR FRAME. WOOD DOOR TO REMAIN UNPAINTED. CUT DOWN WOOD DOORS AS REQ'D FOR NEW TILE FLOORING. PROVIDE KICKPLATE ON PUSH SIDE OF DOOR - REFER TO SPECS.

NEW VENT IN TOE KICK - REFER TO MECH.

NEW WATCHDESK - REFER TO MILLWORK DETAILS

NEW BACKPAINTED GLASS MARKERBOARD - REFER TO SPECS & INTERIOR ELEVATIONS

INTERIOR RENOVATIONS

BID OPPORTUNITY 280-2020

EXISTING WALL TO BE DEMOLISHED

NEW WALL

EXISTING WALL TO REMAIN

EXISTING DOOR TO REMAIN

FLOOR PLAN LEGENDWF WATER FOUNTAINGR FLAT GRILLSPK SPEAKERFR FRIDGEPOP POPCORN MACHINETD TOWEL DISPENSERMW MICROWAVEDW DISHWASHERST STOVECO COFFEE GRINDERCM COFFEE MAKERCG CORNER GUARDWA WASHING MACHINEDR DRYERPH PHONESPK SPEAKERT THERMOSTATFE FIRE EXTINGUISHER

EXISTING CONC. BLOCK WALL TO REMAIN

NEW DOOR

EXISTING DOOR TO BE DEMOLISHED

FLOOR FINISH LEGENDWALL TYPES:

5/8" TYPE 'X' GYPSUM BOARD, PAINT FINISH3 5/8" STEEL STUDS @ 16" O.C.3 1/2" MINERAL FIBER INSULATION5/8" TYPE 'X' GYPSUM BOARD, PAINT FINISH

PARTITIONS TO RUN TO EXISTING CEILING HEIGHT OF ±9'-0"

W1

SPK

SPK

SHOWER

HOSE TOWERG-20

DN

W5DORMITORY

M-01

RESCUEM-04

WATER

STAIRHALLM-03

W/CM-023

4021

3

3128

3438

FE

16

25

18

2518

31

MEZZANINE DEMOLITION PLANSCALE: 1/8" = 1'-0"

2A1.0

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

32.

DEMOLISH EXISTING WALL HOOKS. PATCH & MAKE GOOD ALL ADJACENT SURFACES, TYP.

EXISTING FAUCET TO BE DEMOLISHED - TYPICAL. REFER TO MECH.

DEMOLISH EXISTING STOVE & EXHAUST HOOD. REFER TO MECH & ELECT.

EXISTING FLOORING TO REMAIN.

DEMOLISH EXISTING WALL MOUNTED SHELF AND REDUNDANT BRACKETS. PATCH, REPAIR & PAINT ALL SURFACES.

DEMOLISH EXISTING WALL INCLUDING ALL EXISTING ELECTRICAL. PATCH & MAKE GOOD ALL ADJACENT SURFACES. REFER TO ELECT.

DEMOLISH EXISTING BLINDS. PATCH & REPAIR ALL SURFACES

DEMOLISH EXISTING SPEAKER - REFER TO ELECT. PATCH & MAKE GOOD ALL SURFACES.

EXISTING MICROWAVE TO BE RELOCATED. PROTECT DURING CONSTRUCTION.

EXISTING COFFEE MAKER & COFFEE GRINDER TO BE RELOCATED. PROTECT DURING CONSTRUCTION.

REMOVE EXISTING WHITEBOARD/CORKBOARD AND SALVAGE FOR REINSTALLATION.

REMOVE EXISTING WHITEBOARD/CORKBOARD & RETURN TO CONTRACT ADMINISTRATOR.

DEMOLISH EXISTING WALL INCLUDING ALL EXISTING ELECTRICAL. PATCH & MAKE GOOD ALL ADJACENT SURFACES. RELOCATE EXISTING HUMIDISTAT & SPEAKER VOLUME DIAL AS SHOWN ON RENOVATION PLAN. REFER TO ELECT/MECH.

EXISTING HVAC UNIT TO REMAIN - REFER TO MECH.

DEMOLISH EXISTING DOOR & FRAME.

DEMOLISH ALL EXISTING WALL SCONCES, TYP. REFER TO ELECT. PATCH & MAKE GOOD ALL WALL SURFACES.

EXISTING SHELVING UNIT TO REMAIN. PROTECT DURING CONSTRUCTION.

DEMOLISH KITCHEN SINK, REFER TO MECHANICAL.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

32.

33.

NEW WATCHDESK - REFER TO MILLWORK DETAILS

NEW BACKPAINTED GLASS MARKERBOARD - REFER TO SPECS & INTERIOR ELEVATIONS

PROVIDE NEW CUSTOM WALL MOUNTED SHELF. REFER TO DETAILS.

PATCH & PAINT ALL GWB SURFACES

NEW DISHWASHER - REFER TO MECHANICAL AND SPEC

PAINT ALL WALLS & INSTALL NEW FLOORING & BASEBOARD THROUGHOUT. REFER TO FLOOR FINISH PLAN AND ROOM SCHEDULE AND SPECS.

PAINT EXISTING STAIR RAILING & METAL STRINGERS, BOTH SIDES.

TV AND MOUNT SUPPLIED BY CONTRACT ADMINISTRATOR. CONTRACTOR TO PROVIDE BLOCKING AS REQ'D AND INSTALL TV & MOUNT.

NEW STACKED WASHER & DRYER. REFER TO SPECS, MECHANICAL & ELECTRICAL.

INSTALL EXISTING WHITEBOARD/CORKBOARD. CO-ORDINATE EXACT LOCATION WITH CONTRACT ADMINISTRATOR.

NEW GREASE INTERCEPTOR BELOW SINK - REFER TO MECH.

PATCH & PAINT ALL SIDES OF EXISTING GWB MECHANICAL SURROUND TO MATCH WALL.

PAINT EXISTING WINDOW FRAME. REFER TO ROOM SCHEDULE.

REMOVE EXISTING CLOCK FOR PATCHING AND PAINTING. REINSTALL IN ORIGINAL LOCATION, TYP.

REMOVE EXISTING ARTWORK FOR PATCHING AND PAINTING. REINSTALL IN ORIGINAL LOCATION, TYP.

RELOCATED GAS DETECTION - REFER TO ELECT/MECH.

RELOCATED HUMIDISTAT - REFER TO MECH.

REINSTALL EXISTING LOCKERS IN ORIGINAL LOCATIONS. FASTEN TO FLOOR AND WALL AS PER ORIGINAL CONDITION, TYP.

32.

33.

34.

35.

36.

37.

38.

39.

40.

41.

42.

43.

44.

45.

46.

47.

RELOCATED HUMIDISTAT - REFER TO MECH.

REINSTALL EXISTING LOCKERS IN ORIGINAL LOCATIONS. FASTEN TO FLOOR AND WALL AS PER ORIGINAL CONDITION, TYP.

PROVIDE RUBBER TREADS ON STAIR WITH CONTRASTING COLOUR STRIP. SEE SPECIFICATIONS.

EXISTING CLOSET ROD & SHELF TO REMAIN. PAINT SHELF & CLEATS TO MATCH WALL.

RELOCATED SPEAKER VOLUME DIAL - REFER TO ELECT.

NEW STORAGE CABINETS. REFER TO MILLWORK DETAILS.

NEW MILLWORK - REFER TO DETAILS

INSTALL NEW MOTION SENSOR FAUCETS - REFER TO MECH

PAINT ALL WALLS. REFER TO ROOM SCHEDULE AND SPECS. EXISTING FLOORING TO REMAIN.

CHAIRS (N.I.C.)

EXISTING FLOOR GRILLE TO REMAIN, TYP.

NEW WOOD DOOR & METAL FRAME - REFER TO SPECIFICATIONS. PROVIDE KICKPLATE ON PUSH SIDE OF DOOR - REFER TO SPECS.

NEW INTEGRATED STAINLESS STEEL SINK - REFER TO SPECS, DETAILS AND MECHANICAL.

NEW ELECTRIC RANGE - REFER TO ELECTRICAL & SPECIFICATIONS

INSTALL NEW MOISTURE RESISTANT GWB BEHIND THE ENTIRE LENGTH OF KITCHEN WALL TO 7'-8" HIGH & BEHIND STAINLESS STEEL BACKSPLASH. PATCH & MAKE GOOD ALL SURFACES. REFER TO INTERIOR ELEVATIONS.

ADD PUSH PLATE TO DOOR - REFER TO SPECS.

31.

32.

33.

34.

35.

36.

37.

38.

39.

40.

41.

42.

43.

44.

EXISTING SHELVING UNIT TO REMAIN. PROTECT DURING CONSTRUCTION.

DEMOLISH KITCHEN SINK, REFER TO MECHANICAL.

REMOVE & REPLACE EXISTING WIREMOLD & EXTEND TO NEW MILLWORK - REFER TO INT. ELEVATIONS. PATCH ALL SURFACES.

REMOVAL & REINSTALLATION OF ALL EXISTING FURNITURE / EQUIPMENT FOR FLOORING INSTALLATION TO BE COMPLETED BY OTHERS, TYP. PROTECT ALL FURNITURE DURING CONSTRUCTION. (NOTE: NOT ALL FURNITURE/EQUIPMENT IS SHOWN).

REMOVE & RELOCATE EXISTING WALL MOUNTED TOWEL DISPENSER

EXISTING TOWEL BAR TO REMAIN. PROTECT DURING CONSTRUCTION.

RELOCATE EXISTING GAS DETECTOR - REFER TO ELECT & RENOVATION PLAN.

EXISTING GAS DETECTOR TO REMAIN. REFER TO ELECT.

DEMOLISH UNDERCOUNTER LIGHTING - REFER TO ELECT.

REMOVE EXISTING LOCKERS & STORE FOR REINSTALLATION.

EXISTING FLOOR GRILLE TO REMAIN, TYP. REFER TO FLOOR FINISH PLAN.

DEMOLISH EXISTING DISHWASHER

CONTRACTOR TO REMOVE & REINSTALL EXISTING SHELVING UNIT. DISASSEMBLE / REASSEMBLE AS REQ'D.

DEMOLISH EXISTING GWB BEHIND ENTIRE LENGTH OF KITCHEN WALL UP TO 7'-8" HIGH. REFER TO INTERIOR ELEVATIONS.

NOTE: CONTRACTOR TO PROVIDE NEW PENETRATION IN ROOF AS REQUIRED FOR MECHANICAL DUCTWORK. CONTRACTOR TO PROVIDE FLASHING AND SEAL AS PER INDUSTRY STANDARDS.

Page 3: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

A1.119089A

REFLECTED CEILING PLANS

WINNIPEG FPS FIRE STATION #13

NO.

0

DATE

25.06.2020

REVISION / ISSUANCE

-

1 DD.MM.YYYY -

2 DD.MM.YYYY -

3 DD.MM.YYYY -

4 DD.MM.YYYY -

Seal

Engineer

Project

Sheet Title

Project No.

Date

Sheet

25.06.2020

Architect

799 LILAC STREET

ISSUED FOR CONSTRUCTION

±7'-4"

±9'-0"

±7'-4"

±7'-4"

±9'-0"

±9'-0"

±9'-0"±9'-0"

±9'-0"

±9'-0"

±9'-0" ±9'-0"

±9'-0"

±9'-0"

±9'-0"

±9'-0"

±9'-0"

ROOMG-12

APPARATUS

VESTIBULEG-19

ROOMG-14

MECHANICAL RECEPTIONG-02

ROOMG-23

CONTROL

OFFICEG-05

LIEUTENANT'S

OFFICEG-06

CAPTAIN'S

LOUNGEG-07

KITCHENG-08

CORRIDORG-03

CORRIDORG-13

WASHROOMG-16

MEN'S

SHOWERG-15

ROOMG-11

STATIONARY

WASHROOMG-09

UNISEX

DORMITORYG-18

VESTIBULEG-01

ROOMG-22

STORAGE

HOSE TOWERG-20

ROOMG-21

DRYING

ROOMG-10

CLEANING

6 6

7

7

7

2

2

3 3

3333

4

13

1

1

1

1

10

1

1

1

5

1

ROOMG-04

PHONE

3315

10

11

10

1010

10 10

10

10

10 10

12 12 12

121212

10

10

10

10

10

12

1212

12

22

2

2

13

1415

15

MAIN FLOOR RCP - DEMOLITIONSCALE: 1/8" = 1'-0"

1A1.1

±7'-4"

±9'-0"

±7'-4"

±7'-4"

±9'-0"

±9'-0"

±9'-0"±9'-0"

±9'-0"

±9'-0"

±9'-0" ±9'-0"

±9'-0"

±9'-0"

±9'-0"

±9'-0"

±9'-0"

ROOMG-12

APPARATUS

VESTIBULEG-19

ROOMG-14

MECHANICAL RECEPTIONG-02

ROOMG-23

CONTROL

OFFICEG-05

LIEUTENANT'S

OFFICEG-06

CAPTAIN'S

LOUNGEG-07

KITCHENG-08

CORRIDORG-03

CORRIDORG-13

WASHROOMG-16

MEN'S

SHOWERG-15

ROOMG-11

STATIONARY

WASHROOMG-09

UNISEX

DORMITORYG-18

VESTIBULEG-01

ROOMG-22

STORAGE

HOSE TOWERG-20

ROOMG-21

DRYING

ROOMG-10

CLEANING

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1 1

1

3

4

5

5

55

5

5

3

3

3

3

3 3

5 5 5 5

5555

5

5

3

5

5

3

3

5 5 5

555

33

33

33

3 3

3

3

3

3

3

6

6

6

5

5

±7'-4"

MAIN FLOOR RCP - RENOVATIONSCALE: 1/8" = 1'-0"

2A1.1

9

8

1

1 7

10

12

10 10

12

1 1 1

1

6 ±7'-10"±7'-10"

±7'-10"

±7'-10"

DORMITORYM-01

RESCUEM-04

WATER

STAIRHALLM-03

W/CM-02

MEZZANINE RCP - DEMOLITIONSCALE: 1/8" = 1'-0"

3A1.1

INTERIOR RENOVATIONS

BID OPPORTUNITY 280-2020

DEMOLITION RCP NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

EXISTING LIGHTING FIXTURES TO REMAIN, TYP.

EXISTING PENDANT FIXTURE TO BE REPLACED W/ POT LIGHT - REFER TO ELECT.

PREPARE EXISTING JUNCTION BOX FOR NEW POT LIGHT FIXTURE. PATCH & MAKE GOOD CEILING & ADJACENT SURFACES. PAINT EXISTING CEILING. REFER TO ELECTRICAL.

REMOVE EXISTING LIGHTING IN PHONE ROOM. REFER TO ELECTRICAL. PATCH & MAKE GOOD ALL ADJACENT SURFACES.

EXISTING SPEAKER TO REMAIN. PROTECT DURING CONSTRUCTION.

EXIT SIGN TO REMAIN. PROTECT DURING CONSTRUCTION.

EXISTING CEILING GRILLES TO REMAIN, TYP. PROTECT DURING CONSTRUCTION.

EXISTING DUCT TO REMAIN. REPAIR DRYWALL AROUND DUCT PENETRATION THROUGH CEILING.

EXISTING CEILING HATCH TO REMAIN. REPAIR DRYWALL AROUND HATCH OPENING.

EXISTING SURFACE MOUNTED FIXTURE TO BE REPLACED - REFER TO ELECT.

EXISTING WALL MOUNTED FIXTURE TO BE REPLACED - REFER TO ELECT.

EXISTING POT LIGHT FIXTURE TO BE REPLACED. REFER TO ELECT.

REMOVE EXISTING POT LIGHT FIXTURE IN LIEUTENANT'S OFFICE. REFER TO ELECTRICAL. PATCH & MAKE GOOD ALL SURFACES.

REMOVE SURFACE MOUNTED ELECTRICAL. PATCH & REPAIR ALL ADJACENT SURFACES. REFER TO ELECT.

RENOVATION RCP NOTES

1.

2.

3.

4.

5.

6.

PATCH & PAINT EXISTING CEILING - REFER TO ROOM SCHEDULE

NEW STEEL STUD GWB BULKHEAD. HEIGHT TO MATCH CEILING HEIGHT IN ROOM G-02.

NEW SURFACE MOUNTED LIGHT FIXTURE - REFER TO ELECT.

NEW WALL MOUNTED LIGHT FIXTURE - REFER TO ELECT.

NEW POT LIGHT FIXTURE - REFER TO ELECT.

UNDERCABINET LIGHTING - REFER TO ELECT.

±7'-10"±7'-10"

±7'-10"

±7'-10"

DORMITORYM-01

RESCUEM-04

WATER

STAIRHALLM-03

W/CM-02

111 5

3

5

3 3

1

MEZZANINE RCP - RENOVATIONSCALE: 1/8" = 1'-0"

4A1.1

NEW TILE FLOORING & BASE - REFER TO SPECIFICATIONS

NEW RESILIENT SHEET FLOORING & RUBBER BASE - REFER TO SPECIFICATIONS

NEW RUBBER TILE FLOORING & RUBBER BASE - REFER TO SPEC

NEW RUBBER STAIR TREADS C/W CONTRASTING COLOUR STRIP& PAINTED METAL STRINGERS - REFER TO SPECS

EXISTING FLOORING TO REMAIN

REFLECTED CEILING PLAN LEGEND

EXISTING STIPPLE CEILING - PATCH AND PAINT.- REFER TO ROOM SCHEDULE FOR FINISH

NEW GWB CEILING - REFER TO ROOM SCHEDULE FOR FINISH

EXISTING CEILING TO REMAIN. PATCH & PAINT.- REFER TO ROOM SCHEDULE FOR FINISH

EXISTING CEILING TO REMAIN.

13.

14.

15.

REMOVE EXISTING POT LIGHT FIXTURE IN LIEUTENANT'S OFFICE. REFER TO ELECTRICAL. PATCH & MAKE GOOD ALL SURFACES.

REMOVE SURFACE MOUNTED ELECTRICAL. PATCH & REPAIR ALL ADJACENT SURFACES. REFER TO ELECT.

EXISTING SURFACE MOUNTED FIXTURE TO BE REPLACED & RELOCATED - REFER TO ELECT. PATCH & MAKE GOOD ALL SURFACES.

GENERAL NOTES:

THESE DRAWINGS SHALL NOT BE SCALED.

THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY ONESELF ALL DIMENSIONS, DATUM, AN DETAILED INFORMATION SHOWN ARE CORRECT.

THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGS FOR DUCT, PIPE & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS.

ALL OPENINGS THROUGH FIRE ASSEMBLIES ARE TO BE FIRESTOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER.

ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITH MANUFACTURER'S SPECIFICATIONS & APPLICABLE CODES.

THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTING CONSTRUCTION AFFECTED BY DEMOLITION AND THE REMOVAL OF ALL ITEMS FORMING PART OF THE RENOVATION WORK.

WHERE NEW FLOORING AND BASE IS TO BE INSTALLED IN EXISTING AREAS (REFER TO FLOOR PLAN AND ROOM SCHEDULE) THE EXISTING FLOORING SURFACE AND BASE MUST BE REMOVED, UNLESS OTHERWISE NOTED. ALL FLOOR SURFACES SHALL BE PREPARED IN ACOORDANCE TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF NEW FLOOR.

WHERE PAINTING OF EXISTING WALLS & CEILINGS IS INDICATED ON THE ROOM SCHEDULE, THESE WALLS MUST BE CLEANED OF ANY EXISTING WALL COVERING, PATCHED & PREPARED TO ACCEPT NEW PAINT, UNLESS OTHERWISE NOTED.

ALL EXISTING FURNITURE, EQUIPMENT (INCLUDING GYM EQUIPMENT), AND WALL MOUNTED ITEMS/ ARTWORK/ MAPS/ EXIT PLANS ARE TO BE REMOVED AND REINSTALLED BY THE CITY OF WINNIPEG'S MOVERS (TO BE STORED IN THE APPARATUS ROOM OR A STORAGE CONTAINER AS REQ'D).

EMERGENCY LIGHTING TO BE REPLACED, REFER TO ELECTRICAL FOR SCOPE OF WORK.

ALL MISCELLANEOUS FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED FOR FLOORING INSTALLATION.

ALL MECHANICAL WALL VENTS/GRILLES TO BE REMOVED & REINSTALLED FOR PAINTING.

ALL EXISTING DOORS ARE TO BE CUT DOWN OR ADJUSTED AS REQUIRED TO ACCOMMODATE NEW FLOORING THICKNESS. PATCH & MAKE GOOD ALL DOORS.

ALL FIRE EXTINGUISHERS TO BE REMOVED AND REINSTALLED FOR PAINTING.

WARNING:ASBESTOS MAY BE PRESENT BEHIND WALLS CEILING SPACE & FLOORS. IF ASBESTOS OR ANY HAZARDOUS MATERIAL IS FOUND STOP WORK IMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS PH: 204-986-2351.

Page 4: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

4A1.2

±7'-4

" (S

ITE

CO

NFI

RM

)

TO U

/S O

F N

EW

BU

LKH

EA

D6"

±12'-1"

SITE CONFIRMEQ. EQ. EQ. EQ.

LOCKABLE DOORS, TYP. (4) HEAVY DUTY HINGES AT EACH FULL HEIGHT DOOR. REFER TO SPECS.

COORDINATE LOCATION OF VENT IN PLAM KICK WITH MECHANICAL

PAINT GWB BULKHEAD

6"

ADJUSTABLE S.S. SHELVING

CONTINUOUS SEALANT

ADJUSTABLE S.S. SHELVING

REMOVABLE CLIP ON S.S.KICKPLATE

S.S. ADJUSTABLE BULLETFEET

S.S. DRAWER

NEW MOISTURE RESISTANT GWB TO 7'-8" HIGH & BEHIND S.S. BACKSPLASH. REFER TO FLOOR PLANS FOR LOCATIONS.

S.S. BACKSPLASH COUNTERTOP & WRAPAROUND NOSING

2'-6"2'-0" AT COFFEE STATION

1'-0"

2'-8

"

2'-0

"

1 1/

2"1"

1 1/

2"

7'-8

"

3'-0

"

STAINLESS STEEL BACK PANEL

1"

STAINLESS STEEL BACK PANEL

STAINLESS STEEL KICK PLATE AT SIDES, TYP.

1 1/

2"

1'-0"

2'-6"

1'-6

"

7'-8

"

3'-0

"

1 1/

2"1

1/2"

3'-2

"

CO

OR

DIN

ATE

W/ F

AUC

ET

3"

ADJUSTABLE S.S. SHELVING

CONTINUOUS SEALANT

INTEGRATED S.S.WELDED SINK

18"X30"X10"REFER TO SPECS

NEW MOISTURE RESISTANT GWB TO 7'-8" HIGH & BEHIND S.S. BACKSPLASH. REFER TO FLOOR PLANS FOR LOCATIONS.

S.S. BACKSPLASH COUNTERTOP & WRAPAROUND NOSING 3"

9"1

1/2"

1 1/

2"6"

6"

STAINLESS STEEL BACK PANEL

1'-6"

STAINLESS STEEL BACK PANEL

COORDINATE S.S. BACKSPLASH DIMENSIONS WITH FAUCET. PROVIDE BLOCKING AS REQ'D TO MOUNT FAUCET.

1"

CONTINUOUS SEALANT

S.S. SKIRT TO COVER SINK

STAINLESS STEEL BACK PANEL

STAINLESS STEEL BACKSPLASH

STAINLESS STEEL BACK PANEL

ADJUSTABLE S.S. SHELVING

GREASE INTERCEPTOR, REFER TO MECH. COORDINATE HOLE IN BASE OF S.S. MILLWORK W/ MECH.

NEW MOISTURE RESISTANT GWB TO 7'-8" HIGH & BEHIND S.S. BACKSPLASH. REFER TO FLOOR PLANS FOR LOCATIONS.

ELECTRICRANGE

DISHWASHER(DW)

EQ. EQ.

1 1/2" TYP.

DRAWER

1A1.2

AS REQ'D FORGREASE INTERCEPTOR

RELOCATEDMICROWAVE

RELOCATEDFRIDGE

AS REQ'D FOR RANGE ±6'-11"

EQ.

RELOCATEDTOASTER

3A1.2

VENT HOODREFER TO SPECS

& MECH

RELOCATEDFRIDGE

DRAWER

EQ.

S.S. BACKSPLASH

±5'-9"±6'-11"±6'-10 1/2"

EQ. EQ.

DRAWER DRAWER

6"

3'-2

"

CO

OR

DIN

ATE

W/ F

AUC

ET

7'-8

"

6"

3'-0

"1'

-6" 1'-0

"

S.S. CONTINUOUS BEHIND VENT HOOD & DUCT

UNDERCOUNTER LIGHTING, TYP. REFER TO ELECT.

2A1.2

RELOCATEDKNIFEBLOCK

KNIFE MAGNET BAR AS SPEC'D

AS REQ'D FOR DISHWASHER

±6'-11" GREASE INTERCEPTOR, REFER TO MECH. COORDINATE HOLE IN BASE OF S.S. MILLWORK W/ MECH.

NEW FAUCET,REFER TO SPECS.

6'-8

"

EQ. EQ.

STAINLESS STEEL BEHIND KITCHEN CABINETS, TYP.

STAINLESS STEEL BEHIND KITCHEN CABINETS, TYP.

STAINLESS STEEL BEHIND KITCHEN CABINETS, TYP.

AS REQ'D FOR HOOD

PATCH & PAINT ALL GWB (EXPOSED GWB SHOWN HATCHED)

PROVIDE REMOVABLE CLIP AND S.S. KICKPLATE ON FRONT & SIDES, TYP.

S.S. BACKSPLASH CONTINUOUS BEHIND RANGE

INTEGRATED S.S. SINK 18"X30"X10", REFER TO SPEC

UNDERCOUNTERLIGHTING, TYP.

REFER TO ELECT.

COORDINATE W/ ELECT FOR RECEPTACLE OPENING IN S.S. BACKSPLASH, TYP.

NEW MOISTURE RESISTANT GWB

NEW MOISTURE RESISTANT GWB TO 7'-8" HIGH & BEHIND S.S. BACKSPLASH.

A1.219089A

INTERIOR ELEVATIONS &

WINNIPEG FPS FIRE STATION #13

NO.

0

DATE

25.06.2020

REVISION / ISSUANCE

-

1 DD.MM.YYYY -

2 DD.MM.YYYY -

3 DD.MM.YYYY -

4 DD.MM.YYYY -

Seal

Engineer

Project

Sheet Title

Project No.

Date

Sheet

25.06.2020

Architect

799 LILAC STREET

ISSUED FOR CONSTRUCTION

INTERIOR ELEVATION - G-08 LIVING AREASCALE: 1/2" = 1'-0"

8A1.2

KITCHEN CABINETS - TYP. SECTION DETAILSCALE: 3/4" = 1'-0"

1A1.2

KITCHEN CABINETS - SECTION DETAILSCALE: 3/4" = 1'-0"

2A1.2

INTERIOR RENOVATIONS

BID OPPORTUNITY 280-2020

PULLS AS SPECIFIEDLOCKS AS SPECIFIED(4) HEAVY DUTY HINGES AT EACH FULL HEIGHT DOOR

6" BASEBOARD (PLAM-2)

CENTER SHELF FIXED ADJUSTABLE SHELVES RECESSED METAL STANDARDS

3/4" BIRCH SHELVES C/W 1" EDGE DETAIL WITH CLEAR COAT FINISH

DOOR FRONTS TO BE PLAM-2

±7'-4

" (S

ITE

CO

NFI

RM

)

TO U

/S O

F N

EW

BU

LKH

EA

D

6"

NEW GWB BULKHEAD. REFER TO REFLECTED CEILING PLANS.

COORDINATE LOCATION OF VENT IN PLAM KICK WITH MECHANICAL

EQ. EQ.

NEW POT LIGHT FIXTURE, REFER TO ELECT

2'-6"

PLAM-2 FILLER PANEL AT TOP OF CABINET

3/4" MELAMINE INTERIOR

1 1/

2"

STORAGE CABINETS - SECTION DETAILSCALE: 3/4" = 1'-0"

4A1.2

INTERIOR ELEVATION - STORAGE CABINETSSCALE: 1/2" = 1'-0"

5A1.2

INTERIOR ELEVATION - G-08 COFFEE STATIONSCALE: 1/2" = 1'-0"

7A1.2

1 1/

2"

3 1/2"

8"

3/4"

DRAWER FRONT FULL LENGTH SCALLOPED HANDLE (TYP).

FULL EXTENSION S.S. DRAWER SLIDE 20" LONG

EQ. EQ.

RELOCATEDPOPCORNMACHINE

RELOCATEDTOWEL

DISPENSER

9'-0"

RELOCATEDCOFFEEMAKER

RELOCATEDCOFFEEGRINDER

EQ. EQ.

9'-0"

1 1/2"TYP.

1A1.2

S.S. BACKSPLASH

DRAWER DRAWER DRAWER DRAWER

2'-0

"

7'-8

"

3'-0

"2'

-8"

1'-6

"

6"

UNDERCOUNTER LIGHTING, TYP. REFER TO ELECT.

RELOCATED TABLE

EXISTING SPEAKER TO BE DEMOLISHED, REFER TO ELECT.

RELOCATEDBLENDER

PATCH & PAINT ALL GWB(EXPOSED GWB

SHOWN HATCHED)

S.S. BEHIND KITCHEN CABINETS, TYP.

S.S. BEHIND KITCHEN CABINETS, TYP.

PROVIDE REMOVABLE CLIP AND S.S. KICKPLATE ON FRONT & SIDES, TYP.

COORDINATE W/ ELECT FOR RECEPTACLE OPENING IN S.S. BACKSPLASH, TYP.

KITCHEN CABINETS - SECTION DETAILSCALE: 3/4" = 1'-0"

3A1.2

S.S. DRAWER

1'-0"

2'-8

"

MICROWAVE

1'-0

"

2'-0

" 7'-8

"

3'-0

"

2'-6"

1'-8"

STAINLESS STEEL SHELF

CONTINUOUS SEALANT

ADJUSTABLE S.S.SHELVING

REMOVABLE CLIPON S.S.

KICKPLATES.S. ADJUSTABLE

BULLET FEET

NEW MOISTURE RESISTANT GWB TO 7'-8" HIGH & BEHIND S.S. BACKSPLASH. REFER TO FLOOR PLANS FOR LOCATIONS.

STAINLESS STEEL BACK PANEL

1 1/

2"

NEW TILE BASEBOARD - REFER TO SPECS

6"

PAINT, TYP.

EQ. EQ.

4'-6"

2'-4

1/2

"

4'-8

"

1 1/2" 1 1/2"

1 1/

2"

CL

CL

PULLS AS SPEC'D, TYP.

CONTRACTOR TO INSTALL TV MOUNT & TV AT EXISTING WALL - PROVIDE BLOCKING AS REQ'D.

55" TV - N.I.C.

EXISTING RECEPTACLE

ADJUSTABLE SHELF

REPLACE EXISTING WIREMOLD.EXTEND DATA TO MILLWORK/TV.

PROVIDE NEW WIREMOLD ASREQUIRED TO SUIT A/V REQUIREMENTS.

±5'-3"

TO SUIT EXISTING RECEPTACLE

NEW BLINDS - REFER TO SPECS.

GROMMET AT SIDE OF CABINET FOR DATAWIRING & AT COUNTERTOP/OPEN SHELF

(CENTERED ON DOORS) - GROMMETS ASSPEC'D. REFER TO DETAILS.

GROMMET LOCATED IN OPEN SHELF (CENTERED ON DOORS) & GABLE - GROMMETS AS SPEC'D. REFER TO DETAILS.

9A1.3

NOTE: CONFIRM LOCATION OF TV/TV CABINET WITH ARCHITECT PRIOR TO INSTALLATION OFELECTRICAL/ A/V EQUIPMENT & WIREMOLD

NEW BACKPAINTEDGLASS MAGNETICMARKERBOARD

NEW TILE BASEBOARD - REFER TO SPECS CUT DOWN WOOD DOOR AS REQ'D

FOR NEW FLOORING, TYP. PROVIDE NEW KICK PLATE AT PUSH SIDE OF DOOR, TYP. REFER TO SPECS.

12'-0"

4'-0

"

6"PAINT EXISTING METAL

DOOR FRAME. EXISTINGWOOD DOOR TO REMAIN.

PAINT, TYP.

PH

REMOVE & REINSTALLEXISTING CLOCK, TYP. CL

WHITEBOARD FRAME - REFER TO DETAILS

1 1/2"

DEMOLISH EXISTING PHONE - REFER TO ELECT.

12A1.3

NEW CORNER GUARD - REFER TO SPECS

INTERIOR ELEVATION - G-08 KITCHENSCALE: 1/2" = 1'-0"

6A1.2

INTERIOR ELEVATION - G-08 NEW MARKERBOARDSCALE: 1/2" = 1'-0"

9A1.2

MILLWORK DETAILS

GENERAL NOTES:

THESE DRAWINGS SHALL NOT BE SCALED.

THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY ONESELF ALL DIMENSIONS, DATUM, AN DETAILED INFORMATION SHOWN ARE CORRECT.

THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGS FOR DUCT, PIPE & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS.

ALL OPENINGS THROUGH FIRE ASSEMBLIES ARE TO BE FIRESTOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER.

ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITH MANUFACTURER'S SPECIFICATIONS & APPLICABLE CODES.

THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTING CONSTRUCTION AFFECTED BY DEMOLITION AND THE REMOVAL OF ALL ITEMS FORMING PART OF THE RENOVATION WORK.

WHERE NEW FLOORING AND BASE IS TO BE INSTALLED IN EXISTING AREAS (REFER TO FLOOR PLAN AND ROOM SCHEDULE) THE EXISTING FLOORING SURFACE AND BASE MUST BE REMOVED, UNLESS OTHERWISE NOTED. ALL FLOOR SURFACES SHALL BE PREPARED IN ACOORDANCE TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF NEW FLOOR.

WHERE PAINTING OF EXISTING WALLS & CEILINGS IS INDICATED ON THE ROOM SCHEDULE, THESE WALLS MUST BE CLEANED OF ANY EXISTING WALL COVERING, PATCHED & PREPARED TO ACCEPT NEW PAINT, UNLESS OTHERWISE NOTED.

ALL EXISTING FURNITURE, EQUIPMENT (INCLUDING GYM EQUIPMENT), AND WALL MOUNTED ITEMS/ ARTWORK/ MAPS/ EXIT PLANS ARE TO BE REMOVED AND REINSTALLED BY THE CITY OF WINNIPEG'S MOVERS (TO BE STORED IN THE APPARATUS ROOM OR A STORAGE CONTAINER AS REQ'D).

EMERGENCY LIGHTING TO BE REPLACED, REFER TO ELECTRICAL FOR SCOPE OF WORK.

ALL MISCELLANEOUS FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED FOR FLOORING INSTALLATION.

ALL MECHANICAL WALL VENTS/GRILLES TO BE REMOVED & REINSTALLED FOR PAINTING.

ALL EXISTING DOORS ARE TO BE CUT DOWN OR ADJUSTED AS REQUIRED TO ACCOMMODATE NEW FLOORING THICKNESS. PATCH & MAKE GOOD ALL DOORS.

ALL FIRE EXTINGUISHERS TO BE REMOVED AND REINSTALLED FOR PAINTING.

WARNING:ASBESTOS MAY BE PRESENT BEHIND WALLS CEILING SPACE & FLOORS. IF ASBESTOS OR ANY HAZARDOUS MATERIAL IS FOUND STOP WORK IMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS PH: 204-986-2351.

Page 5: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

1

1

1

2

2

3

3

1

1

1

1

1

1111

1

1

1

8

5

5

5

5

4

155

PT-4

PT-4

PT-4

PT-4

PT-

4

PT-5

PT-

5

PT-4

5

4

3VESTIBULE

G-19

ROOMG-14

MECHANICAL

RECEPTIONG-02

ROOMG-23

CONTROL

OFFICEG-05

LIEUTENANT'S

OFFICEG-06

CAPTAIN'S

LOUNGEG-07

KITCHENG-08

CORRIDORG-03

CORRIDORG-13

WASHROOMG-16

MEN'S

SHOWERG-15

ROOMG-11

STATIONARY

WASHROOMG-09

UNISEX

ROOMG-17

LOCKER

DORMITORYG-18

VESTIBULEG-01

HOSE TOWERG-20

UP

ROOMG-10

CLEANING

MAIN FLOOR FINISH PLANSCALE: 1/8" = 1'-0"

1A1.3

A1.319089A

FLOOR FINISH PLANS, INTERIOR

WINNIPEG FPS FIRE STATION #13

NO.

0

DATE

25.06.2020

REVISION / ISSUANCE

-

1 DD.MM.YYYY -

2 DD.MM.YYYY -

3 DD.MM.YYYY -

4 DD.MM.YYYY -

Seal

Engineer

Project

Sheet Title

Project No.

Date

Sheet

25.06.2020

Architect

799 LILAC STREET

ISSUED FOR CONSTRUCTION

WATCH DESK ELEVATIONSCALE: 1/2" = 1'-0"

3A1.3

6 6

7

SHOWER

HOSE TOWERG-20

DN

W5DORMITORY

M-01

RESCUEM-04

WATER

STAIRHALLM-03

W/CM-02

MEZZANINE FLOOR FINISH PLANSCALE: 1/8" = 1'-0"

2A1.3

INTERIOR RENOVATIONS

BID OPPORTUNITY 280-2020

NEW DOOR

5/8" TYPE 'X' GYPSUM BOARD, PAINT FINISH3 5/8" STEEL STUDS @ 16" O.C.3 1/2" MINERAL FIBER INSULATION5/8" TYPE 'X' GYPSUM BOARD, PAINT FINISH

PARTITIONS TO RUN TO EXISTING CEILING HEIGHT OF ±9'-0"

FLOOR FINISH LEGEND

NEW TILE FLOORING & BASE - REFER TO SPECIFICATIONS

NEW RESILIENT SHEET FLOORING & RUBBER BASE - REFER TO SPECIFICATIONS

NEW RUBBER TILE FLOORING & RUBBER BASE - REFER TO SPEC

NEW RUBBER STAIR TREADS C/W CONTRASTING COLOUR STRIP& PAINTED METAL STRINGERS - REFER TO SPECS

EXISTING FLOORING TO REMAIN

CONTRACTOR TO CO-ORDINATE OPENING IN MILLWORK FOR EXISTING AND NEW ELECTRICAL RECEPTACLES AND CONDUITS ETC, TYP.

EQ.

55" TV - N.I.C.

CPU

RADIODISPATCH

UNITPHONE

OPEN ADJUSTABLE

SHELVINGCPU

EQ 10" EQ ±5'-3 1/2" ±7'-2 1/2"

EQ EQ EQEQ EQ EQ

NEW BACKPAINTEDGLASS MAGNETICMARKERBOARD

SUPPLY & INSTALLADJUSTABLE

MONITOR ARM W/EXISTING MONITOR,

REFER TO SPEC.

TRASH

EXISTING ELECTRICAL

NEW CORNERGUARD - REFER

TO SPECS

NEW TILE BASEBOARD - REFER TO SPECS

6"

NEW TILE BASEBOARD -REFER TO SPECS

EQ. EQ.

±3'-7"

±3'-7

1/2

"

TO M

ATC

H W

IND

OW

HE

IGH

T

EQ. EQ.

PAINT EXISTING METALDOOR & FRAME, TYP.

PROVIDE NEW KICK PLATEAT PUSH SIDE OF DOOR,

TYP. REFER TO SPECS.

EXISTINGELECTRICAL

PAINT EXISTING WINDOW FRAME

PAINT EXISTING WINDOW FRAME

PAINT, TYP.

EXISTING ELECTRICAL

PHONE

RADIO UNIT

DEFIBBATTERYCHARGER

DEFIBBATTERYCHARGER

RADIO CHARGERS

CL

7A1.3

5A1.3

6A1.3

8A1.3

10"2'-4"

NEW BLINDS - REFER TO SPECS

TV AND MOUNT BY CONTRACTADMINISTRATOR. CONTRACTOR TO

INSTALL TV MOUNT AND TV. PROVIDEBLOCKING AS REQUIRED.

SUPPLY & INSTALL ADJUSTABLE MONITOR ARM W/ EXISTING MONITOR, REFER TO SPEC.

EQ.EQ.

EXISTING FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED FOR FLOORING INSTALLATION, TYP.

LOCKABLE DOORSLOCKABLE DRAWERS

P-LAM WALL CLEAT BELOW (PLAM-1)

P-LAM WALL CLEAT BELOW (PLAM-1)

GROMMET INVERTICAL GABLE

GROMMET IN VERTICAL GABLE

GROMMET IN COUNTER.PROVIDE CABLE RACEWAYBELOW COUNTER TO CPU

CABINET

GROMMET CENTERED IN COUNTER

RADIOCHARGERS

CL

GROMMET IN COUNTER. PROVIDE CABLE RACEWAY BELOW COUNTER TO CPU CABINET

FLOOR FINISH PLAN NOTES

1.

2.

3.

4.

5.

6.

7.

8.

REMOVE & REINSTALL ALL FLOOR GRILLES FOR INSTALLATION OF NEW FLOORING, TYP.

EXISTING RECESSED FLOOR MAT

REMOVE & REINSTALL EXISTING FLOOR RECEPTACLE AS REQ'D FOR NEW FLOORING INSTALLATION. REFER TO ELECT.

PROVIDE FLOORING TRANSITION (TR-2) FROM TILE TO RUBBER TILE FLOORING. REFER TO SPECS.

PROVIDE FLOORING TRANSITION (TR-3) FROM TILE TO EXISTING FLOORING. REFER TO SPECS.

PROVIDE FLOORING TRANSITION (TR-4) FROM RESILIENT SHEET FLOORING TO EXISTING FLOORING. REFER TO SPECS.

PROVIDE FLOORING TRANSITION FROM RESILIENT SHEET FLOORING TO RUBBER TREAD. REFER TO SPECS.

REMOVE EXISTING FLOOR GRILLE AND PROVIDE NEW DUCT EXTENSION TO GRILLE WITHIN STORAGE CABINETS. REFER TO MECH, INTERIOR ELEVATIONS AND DETAILS.

ELEVATIONS & MILLWORK DETAILS

FINISH PLAN GENERAL NOTES:

1. FINISH PLAN TO BE READ IN CONJUNCTION WITH THE PROJECT REQUIREMENTS. 

2. REFER TO ROOM FINISH & SPEC ON A1.4 FOR ALL WALL AND FLOOR FINISHES. 

3. REFER TO REFLECTED CEILING PLANS FOR FINISHES OF ALL CEILINGS, BULKHEADS AND SOFFITS.

4. REFER TO SPEC FOR FINISH CODES.

5. ALL EXISTING HOLLOW METAL DOORS AND FRAMES TO BE PAINTED UNLESS OTHERWISE NOTED.

6. ALL EXISTING MAPLE DOORS TO REMAIN AS IS.

7. PAINT EXPOSED SURFACES OF PAINTABLE GRILLES AND DIFFUSERS TO MATCH THE WALL OR CEILING COLOUR.

8. PAINT ALL PARTITIONS AND PERIMETER WALLS TO U/S OF STRUCTURE WHERE THEY ARE NOT INTERSECTED BY SUSPENDED CEILINGS.

9. PAINT SECURITY AND COMMUNICATIONS BACKBOARDS TO MATCH ADJACENT PARTITIONS.

10. ALL FLOORING CHANGES SHALL OCCUR UNDER CENTRELINE OF DOORS UNLESS OTHERWISE NOTED.

11. PROVIDE FLOOR TRANSITION STRIPS OR METAL DIVIDER STRIPS AS INDICATED ON PLAN AT MATERIAL CHANGES. FEATHER CONCRETE FLOORS WITH CONCRETE TOPPING AS REQUIRED TO BRING ADJACENT MATERIALS FLUSH. LAY OUT ACCURATELY AND MARK CLEARLY FOR CONSULTANT'S REVIEW, THE LOCATIONS OF ALL FLOOR PATTERNS AND MATERIAL CHANGES.  ADJUST LOCATIONS AS REQUIRED BASED ON REVIEW.  OBTAIN CONSULTANT'S APPROVAL OF LOCATIONS PRIOR INSTALLATION.

12. FLOOR FINISHES SHALL BE INSTALLED UNDER MILLWORK CABINETS PRIOR TO INSTALLATION OF MILLWORK.

13. PAINT ALL EXPOSED DUCTS, CONDUITS, JUNCTION BOXES, PIPING AND ANY MECHANICAL, ELECTRICAL OR ARCHITECTURAL FITTINGS.

14. PAINT ALL NEW AND EXISTING WIREMOLDS TO MATCH ADJACENT PARTITIONS.

(PLAM-1) BASE CABINET C/W (PLAM-1) DRAWERS W/ FULL EXSTENSION SLIDES & SOFT CLOSING MECHANISM. DRAWER INTERIOR TO HAVE MELAMINE ON ALL INSIDE FACES. LOCKS & PULLS AS SPEC'D.

6"

1'-8 1/2"

2'-6

"

2'-0"

2'-0

"

8 3/

4"5"

8 3/

4"

ADJUSTABLE SHELF

ADJUSTABLE SHELF

DRAWER

DRAWER

DRAWER

SOLID SURFACE COUNTERTOP (SSC-1) W/ MITERED LEADING EDGE.

SOLID SURFACE (SSC-1) RETURN BEYOND

PLASTIC LAMINATE (PLAM-1) KICK

3 1/2"

6"

2'-2 1/2"

3'-6

"

2'-6"

3'-0

"

SOLID SURFACE COUNTERTOP (SSC-1) W/ MITERED LEADING EDGE. SOLID SURFACE (SSC-1) RETURN BEYOND

PLASTIC LAMINATE BASE C/W 6" HIGH KICK W/ MITERED EDGE (PLAM-1), AND PLASTIC LAMINATE (PLAM-1) ADJUSTABLE SHELVES.

PLASTIC LAMINATE OPEN INTERIOR (PLAM-1)

3 1/2"

(3) GROMMETS AS SPEC'D IN BOTH GABLES

(1) GROMMET AS SPEC'D IN EACH ADJUSTABLE SHELF

CONTRACTOR TO CO-ORDINATEOPENING IN MILLWORK FOR

EXISTING ELECTRICALRECEPTACLES AND CONDUITS ETC,

TYP.

GROMMET AS SPEC'D - CENTEREDIN COUNTERTOP

6"

1'-8 1/2"

2'-6

"

2'-0"

2'-0

"

6"

1'-8 1/2"

ADJUSTABLE SHELF

ADJUSTABLE SHELF

2'-6

"

2'-0"

2'-0

"

CPU

PLASTIC LAMINATE (PLAM-1) BASE CABINET W/ 6" HIGH KICK (PLAM-1). CABINET INTERIOR TO HAVE MELAMINE ON ALL INSIDE FACES. PROVIDE (2) ADJUSTABLE MELAMINE SHELVES PER CABINET. CABINET DOORS, PLASTIC LAMINATE (PLAM-1). LOCKS & PULLS AS SPEC'D.

SOLID SURFACE COUNTERTOP (SSC-1) W/ MITERED LEADING EDGE.

SOLID SURFACE (SSC-1) RETURN BEYOND

SOLID SURFACE COUNTERTOP (SSC-1) W/ MITERED LEADING EDGE. SOLID SURFACE (SSC-1) RETURN BEYOND

PLASTIC LAMINATE (PLAM-1) BASE W/ KICK & MITERED EDGE

PLASTIC LAMINATE GABLE BEYOND (PLAM-1)

PLASTIC LAMINATE OPEN INTERIOR (PLAM-1)

3 1/2"SOLID SURFACE (SSC-1) RETURN BEYOND

3 1/2"

PLASTIC LAMINATE (PLAM-1) KICK

WATCH DESK SECTION DETAILSCALE: 3/4" = 1'-0"

5A1.3

WATCH DESK SECTION DETAILSCALE: 3/4" = 1'-0"

6A1.3

WATCH DESK SECTION DETAILSCALE: 3/4" = 1'-0"

7A1.3

WATCH DESK SECTION DETAILSCALE: 3/4" = 1'-0"

8A1.3

ADJUSTABLE SHELF

6"

1'-8 1/2"

2'-6

"

1'-4

1/2

"

SOLID SURFACE COUNTERTOP (SSC-1) W/ MITERED LEADING EDGE.

SOLID SURFACE (SSC-1) RETURN BEYOND

PLASTIC LAMINATE (PLAM-1) BASE C/W 6" HIGH KICK AND (1) PLASTIC LAMINATE (PLAM-1) ADJUSTABLE SHELF. INTERIOR TO HAVE MELAMINE ON ALL INSIDE FACES.

PLASTIC LAMINATE OPEN INTERIOR (PLAM-1)

3 1/2"

6"1

1/2"2'-0"

CONTRACTOR TOCO-ORDINATE OPENING

IN MILLWORK FOREXISTING ELECTRICAL

RECEPTACLE ANDCONDUITS ETC, TYP.

GROMMET AS SPEC'DIN COUNTERTOP

GROMMET ASSPEC'D IN GABLE

GROMMET AS SPEC'D INOPEN SHELF

TV CABINET SECTION DETAILSCALE: 3/4" = 1'-0"

9A1.3

3'-0

" A.F

.F.

PLASTIC LAMINATE SHELF (PLAM-1) W/ MITERED LEADING EDGE.

PLASTIC LAMINATE SHELF CLEATS (PLAM-1) ANCHORED TO WALL

1 1/

2"

CORNER SHELF ELEVATIONSCALE: 3/4" = 1'-0"

10A1.3

CORNER SHELF PLAN DETAILSCALE: 3/4" = 1'-0"

11A1.3

±1'-3

1/2

"

SIT

E C

ON

FIR

M

±2'-0"

SITE CONFIRM

±3'-2

"

SIT

E C

ON

FIR

M

±2'-9"SITE CONFIRM

10

A1.3

PLASTIC LAMINATE SHELF (PLAM-1) W/ MITERED LEADING EDGE.

PLASTIC LAMINATE SHELF CLEATS BELOW (PLAM-1) SHOWN DASHED

SOLID MAPLE WOOD SURROUND

1/4" THICK MAGNETIC BACK PAINTED GLASS WHITEBOARD (MWB1) INSTALLED W 5/8" 'Z-CLIP'. ENSURE 'Z'-CLIPS' ARE SECURED TO SOLID FRAMING THROUGH EXISTING WALL

SOLID MAPLE WOOD SURROUND C/W RECESSED MARKER TRAY

2'-6

"4'

-0"

NEW TILE BASEBOARD - REFER TO SPECS

PROVIDE (2) LAYERS OF 1/2" PLYWOOD BACKING SECURED TO EXISTING STUDS. SECURE SOLID MAPLE SURROUND TO PLYWOOD BACKING.

WHITEBOARD DETAILSCALE: 3/4" = 1'-0"

12A1.3

5'-0"

1 1/

2"2'

-8"

3'-6"

2'-8

"

CUSTOM QUARTZ (QZ-1) TOP

DOUBLE COLUMN 'T' BASE BY SPEC FURNITURE, REFER TO SPEC.

DOUBLE COLUMN 'T' BASE BY SPEC FURNITURE, REFER TO SPEC.

CUSTOM QUARTZ (QZ-1) TOP

DINING TABLESCALE: 1/2" = 1'-0"

4A1.3

CPU CPUOPEN

ADJUSTABLESHELVING

2'-0

"

DR

AW

ER

INSTALL ADJUSTABLE MONITOR ARM W/ EXISTING MONITOR, REFER TO SPECS.

ADJUSTABLESHELVING

ADJUSTABLESHELVING

ADJUSTABLESHELVING

2'-6

"

CONTRACTOR TO CO-ORDINATE OPENING IN MILLWORK FOR EXISTING AND NEW ELECTRICAL RECEPTACLES AND CONDUITS ETC, TYP.

INSTALL ADJUSTABLE MONITOR ARM W/ EXISTING MONITOR, REFER TO SPECS.

PROVIDE (3) GROMMETS AT EACH GABLE & (1) GROMMET AT THE BACK OF EACH ADJUSTABLE SHELF - REFER TO SECTION DETAILS

GROMMET INCOUNTER (ABOVE)

2'-0

"

EXISTING FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED

GROMMET INVERTICAL GABLE

GROMMET IN VERTICAL GABLE

DR

AW

ER

LOCKABLE DOORS

LOCKABLE DRAWERS

NEW CORNER GUARDSOLID SURFACE RETURN (SSC-1)

W/ MITERED EDGES.

1 1/2"1 1/2"1 1/2"

SOLID SURFACE RETURN (SSC-1)W/ MITERED EDGES.

SOLID SURFACE RETURN (SSC-1) W/ MITERED EDGES.

3 1/2"

1/2"

1 1/

2"

1/2"

WATCH DESK PLAN DETAILSCALE: 1/2" = 1'-0"

13A1.3

GENERAL NOTES:

THESE DRAWINGS SHALL NOT BE SCALED.

THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY ONESELF ALL DIMENSIONS, DATUM, AN DETAILED INFORMATION SHOWN ARE CORRECT.

THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGS FOR DUCT, PIPE & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS.

ALL OPENINGS THROUGH FIRE ASSEMBLIES ARE TO BE FIRESTOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER.

ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITH MANUFACTURER'S SPECIFICATIONS & APPLICABLE CODES.

THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTING CONSTRUCTION AFFECTED BY DEMOLITION AND THE REMOVAL OF ALL ITEMS FORMING PART OF THE RENOVATION WORK.

WHERE NEW FLOORING AND BASE IS TO BE INSTALLED IN EXISTING AREAS (REFER TO FLOOR PLAN AND ROOM SCHEDULE) THE EXISTING FLOORING SURFACE AND BASE MUST BE REMOVED, UNLESS OTHERWISE NOTED. ALL FLOOR SURFACES SHALL BE PREPARED IN ACOORDANCE TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF NEW FLOOR.

WHERE PAINTING OF EXISTING WALLS & CEILINGS IS INDICATED ON THE ROOM SCHEDULE, THESE WALLS MUST BE CLEANED OF ANY EXISTING WALL COVERING, PATCHED & PREPARED TO ACCEPT NEW PAINT, UNLESS OTHERWISE NOTED.

ALL EXISTING FURNITURE, EQUIPMENT (INCLUDING GYM EQUIPMENT), AND WALL MOUNTED ITEMS/ ARTWORK/ MAPS/ EXIT PLANS ARE TO BE REMOVED AND REINSTALLED BY THE CITY OF WINNIPEG'S MOVERS (TO BE STORED IN THE APPARATUS ROOM OR A STORAGE CONTAINER AS REQ'D).

EMERGENCY LIGHTING TO BE REPLACED, REFER TO ELECTRICAL FOR SCOPE OF WORK.

ALL MISCELLANEOUS FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED FOR FLOORING INSTALLATION.

ALL MECHANICAL WALL VENTS/GRILLES TO BE REMOVED & REINSTALLED FOR PAINTING.

ALL EXISTING DOORS ARE TO BE CUT DOWN OR ADJUSTED AS REQUIRED TO ACCOMMODATE NEW FLOORING THICKNESS. PATCH & MAKE GOOD ALL DOORS.

ALL FIRE EXTINGUISHERS TO BE REMOVED AND REINSTALLED FOR PAINTING.

WARNING:ASBESTOS MAY BE PRESENT BEHIND WALLS CEILING SPACE & FLOORS. IF ASBESTOS OR ANY HAZARDOUS MATERIAL IS FOUND STOP WORK IMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS PH: 204-986-2351.

Page 6: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

A1.419089A

SCHEDULES & SPECS

WINNIPEG FPS FIRE STATION #13

NO.

0

DATE

25.06.2020

REVISION / ISSUANCE

-

1 DD.MM.YYYY -

2 DD.MM.YYYY -

3 DD.MM.YYYY -

4 DD.MM.YYYY -

Seal

Engineer

Project

Sheet Title

Project No.

Date

Sheet

25.06.2020

Architect

799 LILAC STREET

ISSUED FOR CONSTRUCTION

ROOM FINISH SCHEDULES

ROOM NO. ROOM NAME FLOOR CEILING BASEBOARD NORTHWALL BLINDS

EX

GENERAL NOTES: PATCH & REPAIR ALL EXISTING DAMAGE TO GWB WALLS REFER TO FLOOR FINISH PLANS, SPECIFICATIONS & REFLECTED CEILING PLANS

NOTES: 1. ALL WALLS TO BE PAINTED PT-1 UNLESS OTHERWISE NOTED. 2. ALL CEILINGS AND GB BULKHEADS TO BE PAINTED PT-2 UNLESS OTHERWISE NOTED. 3. ALL DOORS AND FRAMES TO BE PAINTED PT-3 UNLESS OTHERWISE NOTED. WINDOW FRAMES (WHERE PAINTING IS NOTED) TO BE PAINTED PT-3.4. PROVIDE TR-1/TR-2 WHERE ALL QT-1 FLOOR AND BASE IS SPECIFICIED. REFER TO FLOORING ACCESSORIES SPECIFICATION.5. PAINT EXISTING STEEL STAIR STRINGERS AND RAILING PT-3

ABBREVIATIONS:PT PAINTEPT EPOXY PAINTEX EXISTINGQT PORCELAIN QUARRY TILERSF RESILIENT SHEET FLOORINGRF RUBBER TILE FLOORINGRCB RUBBER COVE BASERST RUBBER STAIR TREADRS ROLLER SHADES

PT-1: (WALL COLOUR):MANUFACTURER: BENJAMIN MOORE PAINTSCOLOR: OC 17 WHITE DOVEFINISH: PEARL FINISH FOR DRYWALL; SEMI GLOSS FINISH FOR CONCRETE BLOCK WALLSSUGGESTED LOCATION: MAIN WALL PAINT

PT-2: (CEILINGS):MANUFACTURER: BENJAMIN MOORE PAINTSCOLOR: OC 17 WHITE DOVEFINISH: SATIN FINISH

PT-3 (DOORS & FRAMES): MANUFACTURER: DULUX PAINTSCOLOR: BLACK MAGIC DLX1001-7FINISH: SEMI GLOSS FINISH

PT-4: (ACCENT WALL COLOUR):MANUFACTURER: SHERWIN WILLIAMS PAINTCOLOR: SW 7641 COLONNADE GRAYFINISH: PEARL FINISH FOR DRYWALL; SEMIGLOSS FINISH FOR CONCRETE BLOCK WALLS

PT-5: (ACCENT WALL COLOUR):MANUFACTURER: DULUX PAINTSCOLOR: DLX1162-7 DRAGONFLY (CITY OF WINNIPEG BLUE)FINISH: PEARL FINISH FOR DRYWALL; SEMIGLOSS FINISH FOR CONCRETE BLOCK WALLS

EPT-1: (EPOXY PAINT)MANUFACTURER: STONHARD STONEGLAZE VSRCOLOR: TO MATCH BENJAMIN MOORE PAINTS- OC 17 WHITE DOVEFINISH: EPOXY

VESTIBULERECEPTIONG-02

G-01

CORRIDORG-03

LIEUTENANT'S OFFICECAPTAIN'S OFFICE

G-05

LOUNGE

G-06

G-07

G-08

G-09

G-10

STATIONARY ROOM

G-11

APPARATUS ROOM

G-12

CORRIDORG-13

MECHANICAL ROOM

G-14

SHOWERG-15

MEN'S WASHROOM

G-16

LOCKER ROOMG-17

DORM/GYMG-18

VESTIBULEG-19HOSE TOWERG-20

DRYING ROOMG-21

STORAGE ROOMG-22

KITCHEN

UNISEX WASHROOMCLEANING ROOM

DORMITORYM-01WASHROOMM-02STAIRHALLM-03

PT-1PT-1PT-1PT-4

SOUTHWALL

EASTWALL

WESTWALL

WATER RESCUEM-04

G-23 CONTROL ROOM

PT-1PT-1PT-4PT-1PT-1PT-1PT-1PT-4PT-1PT-1PT-1PT-1

PT-1PT-1PT-4PT-1

PT-1PT-1PT-1PT-4

PT-1PT-4PT-1PT-1

EPT-1EPT-1EPT-1EPT-1

EPT-1EPT-1EPT-1EPT-1

PT-1PT-1PT-1PT-1

EXEXEXEX

PT-1PT-1PT-1PT-1

EXEXEXEX

EPT-1EPT-1EPT-1EPT-1

EPT-1EPT-1EPT-1EPT-1

PT-1PT-1PT-1PT-1

PT-4PT-1PT-1PT-1

PT-1PT-1PT-1PT-1

EXEXEXEX

EXEXEXEX

EXEXEXEX

PT-1PT-1PT-1PT-4PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1PT-1

PT-2PT-2PT-2

PT-2

PT-2

PT-2

PT-2

EPT-1

EPT-1

PT-2

EX

PT-2

EX

EPT-1

EPT-1

PT-2

PT-2

PT-2

EX

EX

EX

PT-2PT-2PT-2PT-2PT-2

EX

EX

EX

EX

EX

EX

EXEX

EXEX

EXEX

EXEX

EXEX

EXEX

EX

PORCELAIN QUARRY TILE (QT-1)PRODUCT: C&S TILE CERAMSTONE COLLECTION- ICON COLLECTIONCOLOR: # 5224 JET BLACK; SIZE: 12” X 24” RECTIFIEDRATINGS: (HC) HEAVY COMMERCIAL; COF: >0.60; SLIP RESISTANT R10 MATT FINISH FROST PROOF (FP)TILE BASE: 6" HIGH, CUT TILE BASE TO MATCH. INSTALL SCHLUTER DILEX-AHK PROFILE AND JOLLY AT SPECIFIED. NECESSARY ACCESSORIES/CONNECTORS BETWEEN FLOOR TILE AND WALL BASE TILE TO PROVIDE AN INSIDE COVEPROFILE IN ALL KITCHEN AREAS OR WASHROOM AREAS.GROUT: EPOXY GROUT (GR-1) TO BE INSTALLED WITH FLOOR TILE. REFER TO SPECIFICATIONS.TYPICAL GROUT JOINT WIDTH: ¼”INSTALLATION METHOD: SUGGESTED PATTERN TO BE BRICK LAYOUT PORTLAND CEMENT AS PER NMS 095423 AND MANUFACTURER’SRECOMMENDED SPECIFICATIONS.

EPOXY GROUT (GR-1)PRODUCT: CUSTOM BUILDING PRODUCTS EPOXY CEG-LITE 100% SOLIDS COMMERCIAL EPOXY GROUTCOLOR: #19 PEWTERDESCRIPTION: TWO COMPONENT FORMULA; STAIN AND CHEMICAL RESISTANT.

RUBBER FITNESS FLOORING (RF-1)PRODUCT: VOYAGER ATHLETIC TILE RUBBER FITNESS MATTINGMANUFACTURER: EDGEWOOD ATHLETICSSIZE: 48” X 72”; THICKNESS: 9.5 MM; 6.7 LBS.COLOUR: BLACKDESCRIPTION: SMOOTH FACE TILE; CUT RESISTANT AND NON-ABSORBENT.CONSTRUCTION: POLYURETHANE BONDED RECYCLED RUBBER WITH 100% POST-CONSUMER RECYCLED CONTENT AND20% VIRGIN EPDM GRANULES.WARRANTY: 5 YEAR WARRANTY AVAILABLE.EDGING: EDGEWOOD ATHLETICS CARTSMART REGULAR DUTY RAMP EDGE 3.5” W X 3/8” HIGH FOR ACCESSIBILITY.EDGING INSTALLATION: TO BE INSTALLED WITH MANUFACTURERS RECOMMENDED DOUBLE SIDED 2” WIDE TAPE.

FLOORING ACCESSORIESMETAL TRIM EDGES/ TRANSITION PROFILE (TR-1)MANUFACTURER: SCHLUTERPRODUCT: DILEX-AHK PROFILE AND NECESSARY ACCESSORIES/CONNECTORSFINISH: ALUMINUMLOCATION: INSTALLED BETWEEN FLOOR TILE QT-1 AND WALL BASE TILE TO PROVIDE AN INSIDE COVE PROFILE

METAL TRIM EDGES / TRANSITION PROFILE (TR-2)MANUFACTURER: SCHLUTERPRODUCT: JOLLY 3/8"FINISH: ALUMINUMLOCATION: WALL BASE TOP CAP

METAL TRIM EDGES / TRANSITION PROFILE (TR-3)MANUFACTURER: SCHLUTERPRODUCT: RENO AEVT 100 B40FINISH: ALUMINUMLOCATION: INSTALLED WHERE QT-1 TRANSITIONS TO EXISTING FLOORING.

VINYL TRIM EDGES / TRANSITION PROFILE (TR-4)MANUFACTURER: TARKETTPRODUCT: REDUCER RRS-WG-BFINISH: 20 CHARCOALLOCATION: INSTALLED WHERE RSF-1 TRANSITIONS TO EXISTING

RUBBER COVED BASE (RCB-1)PRODUCT: TARKETT RUBBER (TP) COVED BASESTYLE: TRADITIONAL TOE TYPECOLOUR: 20 CHARCOALHEIGHT: 6” HIGH THICKNESS: 1/8” GAUGEFLAME SPREAD/ SMOKE DENSITY: CLASS B< 450 SMOKEFIRE RESISTANCE: (ASTM E 648) CLASS 1WARRANTY: LIMITED 5 YEAR WARRANTYSUSTAINABILITY: CRADLE TO CRADLE CERTIFICATION, FLOORSCORE CERTIFICATIONINSTALLATION METHOD: AS PER MANUFACTURERS RECOMMENDED ADHESIVE AND APPLICATION METHODS.

RUBBER STAIR TREADS (RST-1)PRODUCT: TARKETT STAIRWELL MANAGEMENT-RESILIENT RUBBER STRINGERS AND RISERSDESCRIPTION: THERMOPLASTIC RUBBER-10” DEEP STRINGER & 7” HIGH RISER (HEIGHT DEPENDING ON STAIR APPLICATION)STYLE: STRINGER- RS-XX RUBBER STRINGER; RISER: RR-XX WITH CONTRASTING TACTILE STRIPTACTILE EDGE STRIP COLOR: MUST MEET WADS STANDARDS FOR CONTRASTING COLORSCOLOUR: 20 CHARCOALTHICKNESS: STRINGER: 0.080” (2MM); RISER:FLAME SPREAD/ SMOKE DENSITY: ASTM E662 NFPA 258 CLASS B< 450 SMOKEFIRE RESISTANCE: (ASTM E 648) NFPA 253- CLASS 1WARRANTY: LIMITED 2 YEAR WARRANTYSUSTAINABILITY: CRADLE TO CRADLE CERTIFICATION, FLOORSCORE CERTIFICATIONINSTALLATION METHOD: AS PER MANUFACTURERS RECOMMENDATIONS AND ADHESIVE AND APPLICATION METHODS.

VINYL TACTILE WARNING SURFACE (VTS-1)PRODUCT: TARKETT STAIRWELL MANAGEMENT-VINYL TACTILE WARNING SURFACEDESCRIPTION: SOLID COLOR TACTILE WARNING SURFACE TILESIZE: 12” X 50’ 1/8”LOCATION: TO BE INSTALLED AT ALL STAIR TRANSITIONS, AS PER WADS, NBC AND MBC.COLOUR: TBD; 36 STANDARD COLORS AVAILABLEFLAME SPREAD/ SMOKE DENSITY: ASTM E662 NFPA 258 CLASS B< 450 SMOKEFIRE RESISTANCE: (ASTM E 648) NFPA 253- CLASS 1WARRANTY: LIMITED 2 YEAR WARRANTYSUSTAINABILITY: CRADLE TO CRADLE CERTIFICATION, FLOORSCORE CERTIFICATIONINSTALLATION METHOD: AS PER MANUFACTURERS RECOMMENDATIONS AND ADHESIVE AND APPLICATION METHODS.

APPLIANCES

COMMERCIAL ELECTRIC RANGE (R-1)PRODUCT: IMPERIAL RANGEMODEL: IR-6-ESIZE: 36”DESCRIPTION: 6 ROUND ELEMENTS; ELECTRIC RANGE; 240V; 72 AMP WITH 4 CASTOR SWIVEL FEETU.L/ ULC COMPLIANTWARRANTY: LIMITED 1 YEAR ONE PARTS AND LABOUR

OVERHEAD HOOD RANGE (OHR-2)PRODUCT: KITCHENAID 36 INCH COMMERCIAL STYLE WALL MOUNT RANGE HOODSIZE: 36” WIDE X 18” HIGH X 25” DEEPMODEL: KVWC906JSS:DESCRIPTION: 108K BTU, 3 SPEED, STAINLESS STEEL FINISH WALL MOUNT CANOPY RANGE HOOD, 10” DUCT; 120VMOUNTING HEIGHT: TO BE DETERMINED ON SITE. NOTE- MUST BE MOUNTED HIGH ENOUGH SO STAFF DO NOT HIT THEIR HEADS.U.L/ ULC COMPLIANTWARRANTY: LIMITED 1 YEAR PARTS AND LABOUR

RESIDENTIAL DISHWASHER (DW-2)PRODUCT: BOSCH 800 SERIES UNDERCOUNTER BUILT IN DISHWASHERSIZE: 23.54” W X 23.7” D X 33.7/8” HFINISH: STAINLESS STEEL6 WASH CYCLES, SANITIZE SETTING, STAINLESS STEEL TUB, FRAME, FILL AND DRAIN TYPE OPERATIONLEAK PROTECTION, 24/7 AQUA STOP; 3RD RACK SYSTEM; UL LISTEDWARRANTY: LIMITED 1 YEAR PARTS AND LABOUR WARRANTY

BATHROOM FAUCET (FCT-1)PRODUCT: DELTA HANDS FREE 591T SERIES ELECTRONIC FAUCET C/W THERMOSTATIC MIXING VALVEDESCRIPTION: SURFACE MOUNT CONTROL BOX BATTERY OPERATED WITH SENSOR CLEARANCE            FINISH: CHROME PLATEDMODEL NO.: 591T1220DIMENSIONS: 5.3” HIGH X 6.5”EXT X 6.25” WIDEINSTALLATION MOUNTING: 4” ON CENTRETHERMOSTATIC MIXING VALVE REQUIRED: MODEL NO.: DELTA #R3070-MIXLFWARRANTY: 5 YEAR LIMITED COMMERCIAL WARRANTY

KITCHEN FAUCET (FCT-2)PRODUCT: T&S BRASS AND BRONZE WORKS INC. COMMERCIAL KITCHEN PULL DOWN FAUCETDESCRIPTION: PRE-RINSE UNIT; 8” WALL MOUNT MIXING FAUCET WITH LEVER HANDLES AND 44” FLEXIBLE STAINLESS STEEL HOSEMODEL NO.: B-0133-BDIMENSIONS: 12 5/8” WIDE X 33 3/8” H X 14 1/16” EXT.TO BE WALL MOUNTED; 1.15 GPM SPRAY VALVE

WASHER & DRYER (STACKING) WASHERPRODUCT: LG 5.2 CU. FT. ULTRA LARGE SMART WI-FI ENABLED FRONT LOAD WASHERMODEL: WM3700HVASIZE: 27" W X 30 3/4" D X 39" HWARRANTY: LIMITED 1 YEAR PARTS AND LABOUR WARRANTY

DRYERPRODUCT: LG 7.4 cu. ft. ULTRA LARGE CAPACITY SMART WI-FI ENABLED ELECTIC DRYERMODEL: DLEX3700VSIZE: 27" W X 30 3/4" D X 39" HWARRANTY: LIMITED 1 YEAR PARTS AND LABOUR WARRANTYSPECIAL: PROVIDE STACKING KIT KSTK1

DIVISION 01 - GENERAL REQUIREMENTS

1. CONTRACTOR TO OBTAIN ALL NECESSARY BUILDING PERMITS & CERTIFICATES.

2. CONTRACTOR MUST HAVE A WRITTEN WORKPLACE SAFETY AND HEALTH PROGRAM IN ACCORDANCE WITH THE WORKPLACE SAFETY AND HEALTH ACT (MANITOBA).

3. CONTRACTOR SHALL BE THE PRIME CONTRACTOR AND SHALL SERVE AS, AND HAVE THE DUTIES OF THE PRIME CONTRACTOR IN ACCORDANCE WITH THE WORKPLACE SAFETY AND HEALTH ACT (MANITOBA).

4. COORDINATE PROGRESS SCHEDULE AND COORDINATE WITH CONTRACT ADMINISTRATOR DURING CONSTRUCTION.

4. RESTRICT USE OF SITE TO AREA AFFECTED BY RENOVATION.

5. PROMPTLY REPORT ALL ACCIDENTS AND POTENTIAL LIABILITY CLAIMS TO THE CONTRACT ADMINISTRATOR.

6. PROTECT EXISTING FINISHES AND EQUIPMENT FROM DAMAGE DURING CONSTRUCTION.

7. AT COMPLETION OF OPERATIONS, CONDITION OF EXISTING WORK TO BE EQUAL OR BETTER THAN THAT WHICH EXISTED BEFORE NEW WORK STARTED.

8. SHOP DRAWING SUBMITTALS REQUIRED: • DOORS & DOOR HARDWARE• DINING ROOM TABLE & BASES• MOVABLE PARTITION• FLOORING AND TRIMS• WALL PROTECTION• PAINT SAMPLES• GLASS MARKER BOARD & FRAMES• WINDOW COVERINGS• APPLIANCES AND EQUIPMENT• WASHROOM ACCESSORIES• MILLWORK & MILLWORK HARDWARE• KITCHEN ACCESSORIES• BLINDS & ROLLER SHADES• ALL MECHANICAL AND ELECTRICAL EQUIPMENT (REFER ALSO TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SHOP DRAWING SUBMITTAL REQUIREMENTS).

9. CLOSE-OUT SUBMITTALS REQUIRED: MANUFACTURER’S LITERATURE FOR ALL PRODUCTS, FINISHES AND/OR EQUIPMENT REQUIRED FOR THIS PROJECT, INCLUDING OPERATING AND MAINTENANCE INFORMATION AS WELL AS PRODUCT WARRANTY. ALL INFORMATION TO BE SUBMITTED DIGITALLY (ONE CD/DVD, PDF FORMAT) AND A SINGLE HARD COPY IN A “D” RING BINDER WITH SPINE AND FACE POCKETS. COVER AND SPINE TO IDENTIFY PROJECT AND SUBJECT MATTER. ARRANGE CONTENT BY SECTION NUMBERS AND SEQUENCE OF TABLE OF CONTENTS.

10. AS-BUILT DRAWINGS: AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR IS TO SUBMIT ONE (1) PAPER COPY (24” x 36”) AND ONE (1) ELECTRONIC COPY (PDF FORMAT) OF “RED-LINED” DRAWINGS AS MAINTAINED AT THE SITE DURING CONSTRUCTION.

11. MECHANICAL BALANCING AND TESTING REPORT(S) AND FIRE ALARM VERIFICATION TO BE SUBMITTED UPON COMPLETION OF WORK (REFER TO MECHANICAL AND ELECTRICAL).

12. WARRANTY FOR ALL WORK RELATED TO THIS PROJECT TO BE MINIMUM ONE (1) YEAR.

13. CONTRACTOR TO NOTIFY CONSULTANT IMMEDIATELY UPON DISCOVERY OF ANY UNKNOWN HAZARDOUS MATERIAL DISCOVERED ON SITE. NO WORK TO BE CONDUCTED IN AREA OF HAZARDOUS MATERIAL UNTIL WRITTEN INSTRUCTION AND APPROVAL HAS BEEN RECEIVED FROM THE CONSULTANT.

14. CONSULTANTS AND CONTRACT ADMINISTRATOR TO HAVE UNRESTRICTED ACCESS TO THE WORK.

15. UTILITIES AND SERVICES, INCLUDING WATER SUPPLY, HEATING AND VENTILATION, AND POWER AND LIGHTING WILL BE AVAILABLE ON SITE. ANY MODIFICATION TO SUCH SERVICES AS REQUIRED BY THIS PROJECT TO BE COORDINATED WITH THE CONTRACT ADMINISTRATOR.

16. EXISTING FACILITIES ARE TO BE PROTECTED FROM DAMAGE AND TO BE KEPT CLEAN AND AT ALL TIMES.

17. CONTRACTOR WILL BE RESPONSIBLE FOR MAINTAINING TEMPORARY FIRE PROTECTION EQUIPMENT DURING PERFORMANCE OF WORK REQUIRED BY GOVERNING CODES, REGULATIONS AND BYLAWS.

18. CONSTRUCTION OFFICE AND TOOLS AND EQUIPMENT STORAGE ARE TO BE THE RESPONSIBILITY OF THE CONTRACTOR. LOCATION OF, AND SERVICES FOR, ANY SUCH TEMPORARY FACILITIES ARE TO BE COORDINATED WITH THE CONTRACT ADMINISTRATOR.

19. DELIVER, STORE AND HANDLE ALL MATERIALS AND PRODUCTS IN ACCORDANCE WITH MANUFACTURER’S WRITTEN INSTRUCTIONS. STORE OFF GROUND, INDOORS IN A DRY WELL VENTILATED AREA. PROTECT FROM NICKS, SCRATCHES OR BLEMISHES AND REPLACE DEFECTIVE OR DAMAGED MATERIALS WITH NEW.

20. MAINTAIN WORK IN TIDY CONDITION, FREE FROM ACCUMULATION OF WASTE PRODUCTS AND DEBRIS.

21. CLEAN INTERIOR AREAS PRIOR TO START OF FINISHING WORK AND MAINTAIN AREAS FREE OF DUST AND OTHER CONTAMINANTS DURING FINISHING OPERATIONS.

22. PROVIDE ADEQUATE VENTILATION CONDITIONS DURING USE OF VOLATILE OR NOXIOUS SUBSTANCES. USE OF BUILDING VENTILATION SYSTEMS IS NOT PERMITTED FOR THIS PURPOSE.

23. CONTRACTOR TO ARRANGE FINAL REVIEW WITH THE CONSULTANT ONCE THE FOLLOWING CHECKLIST HAS BEEN COMPLETED:• WORK HAS BEEN COMPLETED AND INSPECTED BY THE CONTRACTOR FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS;• DEFECTS AND DEFICIENCIES HAVE BEEN CORRECTED AND COMPLETED;• EQUIPMENT AND SYSTEMS HAVE BEEN TESTED, ADJUSTED, BALANCED AND ARE FULLY OPERATIONAL;• CERTIFICATES REQUIRED BY THE AUTHORITY(IES) HAVING JURISDICTION HAVE BEEN SUBMITTED;• OPERATION OF SYSTEMS HAVE BEEN DEMONSTRATED TO THE CONTRACT ADMINISTRATOR’S PERSONNEL;• WASTE PRODUCTS AND DEBRIS HAVE BEEN REMOVED, ALL AREAS AFFECTED BY THE WORK HAVE BEEN CLEANED (ACCORDING TO PROPRIETARY LITERATURE FOR INDIVIDUAL PRODUCTS OR COMPONENTS) AND IS SUITABLE FOR OCCUPANCY.

24. IF DECLARED SUBSTANTIALLY COMPLETE BY THE CONSULTANT, CONTRACTOR TO APPLY FOR CERTIFICATE OF SUBSTANTIAL PERFORMANCE. LIEN AND WARRANTY PERIOD TO COMMENCE UPON DATE OF CONTRACT ADMINISTRATOR’S ACCEPTANCE OF SUBMITTED DECLARATION OF SUBSTANTIAL PERFORMANCE.

DIVISION 02 - EXISTING CONDITIONS

02 41 19 SELECTIVE DEMOLITION• DISCONNECT REMOVE, AND IDENTIFY DESIGNATED UTILITIES WITHIN DEMOLITION AREAS.• DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. PROTECT EXISTING SUPPORTING STRUCTURAL MEMBERS.• REMOVE DEMOLISHED MATERIALS FROM SITE EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. DO NOT BURN OR BURY MATERIALS ON SITE. • REMOVE MATERIALS AS WORK PROGRESSES. UPON COMPLETION OF WORK, LEAVE AREAS IN CLEAN CONDITION.

DIVISION 06 – WOOD, PLASTICS AND COMPOSITES

06 40 00 ARCHITECTURAL WOODWORK

DIVISION 09 - FINISHES

09 21 16 GYPSUM BOARD ASSEMBLIES

WALL FINISH: • CGC TYPE X, 5/8” THICK X 4’0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED, APPLICATION AND FINISHING OF GYPSUM BOARD TO BE IN ACCORDANCE WITH ASTM C840. FINISH FACE PANEL JOINTS, INTERNAL ANGLES, SCREW HEAD DEPRESSIONS WITH JOINT SYSTEM CONSISTING OF JOINT COMPOUND, JOINT TAPE AND TAPING COMPOUND INSTALLED ACCORDING TO MANUFACTURER’S DIRECTIONS AND FEATHERED ONTO PANEL FACES. FINISH CORNER BEADS AND TRIM AS REQUIRED WITH TWO COATS OF JOINT COMPOUND AND ONE COAT OF TAPING COMPOUND FEATHERED OUT ONTO PANEL FACES. COMPLETED INSTALLATION TO BE SMOOTH, LEVEL OR PLUMB, FREE FROM WAVES AND OTHER DEFECTS, READY FOR SURFACE FINISH.

MOISTURE-RESISTANT INTERIOR GYPSUM BOARD:• TO ASTM C 1396M, MOISTURE-RESISTANT, TREATED CORE, MOULD RESISTANCE RATING 10 TO ASTM D 3273. TYPE X, 5/8” THICK FOR WALLS, 1/2” THICK FOR CEILINGS BY 48” WIDE BY MAXIMUM PRACTICAL LENGTH, ENDS SQUARE CUT, LONG EDGES BEVELLED. LOCATION: WASHROOMS AND WHERE INDICATED. STANDARD OF ACCEPTANCE: USG/CGC SHEETROCK BRAND GLASS-MAT PANELS MOLD TOUGH VHI FIRECODE X. ACCESSORIES AS APPROVED BY MANUFACTURER. LEVEL 5 FINISH.

CEILING AND BULKHEAD FINISH: • STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM BOARD TO BE IN ACCORDANCE WITH ASTM C840. FINISH FACE PANEL JOINTS, INTERNAL ANGLES, SCREW HEAD DEPRESSIONS WITH JOINT SYSTEM CONSISTING OF JOINT COMPOUND, JOINT TAPE AND TAPING COMPOUND INSTALLED ACCORDING TO MANUFACTURER’S DIRECTIONS AND FEATHERED ONTO PANEL FACES. FINISH CORNER BEADS AND TRIM AS REQUIRED WITH TWO COATS OF JOINT COMPOUND AND ONE COAT OF TAPING COMPOUND FEATHERED OUT ONTO PANEL FACES. COMPLETED INSTALLATION TO BE SMOOTH, LEVEL OR PLUMB, FREE FROM WAVES AND OTHER DEFECTS, READY FOR SURFACE FINISH.

09 22 16 NON-STRUCTURAL METAL STUD FRAMING• WALLS TO BE CONSTRUCTED WITH NON-LOAD BEARING CHANNEL STUD FRAMING AND TRACKS TO ASTM C645, ROLL FORMED FROM HOT DIPPED GALVANIZED STEEL SHEET, FOR SCREW ATTACHMENT OF GYPSUM BOARD. KNOCK-OUT SERVICE HOLES AT 16” CENTERS. METAL CHANNEL STIFFENERS 3/4” X 16 GAUGE COLD ROLLED STEEL COATED WITH RUST INHIBITIVE COATING.• CONTRACTOR TO DETERMINE APPROPRIATE GAUGE OF STEEL STUD FOR WALL HEIGHT.• REFER TO WALL TYPES FOR WALL FOR STUD SIZING• PROVIDE EXPANSION TRACK AT ALL WALLS THAT GO TO U/S OF STRUCTURE. REFER TO DETAIL.

09 91 99 PAINTING FOR MINOR WORKS

PAINTING• ENSURE ALL SURFACES TO BE PAINTED ARE CLEANED AND DE-GREASED PRIOR TO ANY PAINTING WORK. ENSURE VENTILATION, LIGHT LEVELS, TEMPERATURE, HUMIDITY AND SUBSTRATE MOISTURE CONTENT LEVELS ARE WITHIN THE MANUFACTURER’S PUBLISHED INSTALLATION GUIDE LIMITS.

• SUBMIT 8”x10” OF EACH PAINT WITH THE SPECIFIED PAINT IN COLOURS, GLOSS/SHEEN AND TEXTURES REQUIRED TO MPI (MASTER PAINTERS INSTITUTE) PAINTING SPECIFICATION MANUAL STANDARDS SUBMITTED ON THE FOLLOWING SUBSTRATE MATERIALS: 1/8” PLATE STEEL FOR FINISHES OVER METAL SURFACES, 2” CONCRETE BLOCK FOR FINISHES OVER CONCRETE MASONRY SURFACES, 1/2” GYPSUM BOARD FOR FINISHES OVER GYPSUM BOARD SURFACES.• REFER TO DRAWINGS AND ROOM FINISH SCHEDULE FOR PAINTED SURFACES• IN THE OPEN OFFICE, PAINT ALL EXPOSED STRUCTURE (INCLUDING JOISTS & ROOF DECK), CONDUITS, PIPING, AND OTHER MECHANICAL (INCLUDING DUCT WORK) AND ELECTRICAL EQUIPMENT WITH COLOUR AND FINISH TO MATCH ADJACENT SURFACES, EXCEPT AS NOTED OTHERWISE.

KITCHEN STAINLESS BASE CABINET• 18GA S.S. BASE AND INTERMEDIATE SHELVES• INTERMEDIATE SHELVES TO BE ADJUSTABLE WITH STAINLESS PILASTER STRIPS AND CLIPS• CABINET ENDS AND DIVIDERS TO BE 20GA S.S. T304#4 FINISH• BACK PANEL-20GA S.S. T304#4• REINFORCING 16GA SATINCOAT C-SECTION, DOUBLE - FACE TAPE TO TOP (3 REQ'D)• 16GA SATINCOAT OR GALVANIZED SUPPORT CHANNELS FOR BASE SHELF• 1 5/8" OD - 16GA S.S. ORNAMENTAL TUBULAR LEGS• S.S. ADJ. BULLET FEET• 16GA S.S. T304#4 6" REMOVABLE S.S. KICK PLATE - FRONT & ENDS• 16GA S.S. SKIRTING TO COVER FRONTS OF SINK

KITCHEN STAINLESS DRAWERS• DOUBLE PAN CONSTRUCTION-FRONT-18GA S.S. T304#4• 1" INSULATION BETWEEN PANS• 16GA S.S. T304#4 DRAWER PAN x 8" DEEP FASTENED TO THE BACK PAN OF THE DRAWER FRONT• STAINLESS DRAWER SLIDES x 20"LONG - FULL EXTENSION WEIGHT CAPACITY 80-100 lbs• DRAWER HOUSING - 16GA S.S. T304#4• FASTEN DRAWERS TO UNDERSIDE OF STAINLESS TOP

KITCHEN STAINLESS WALL MOUNTED SHELVES - CABINET STYLE• 18GA S.S. T304#4 BODY, TOP AND SHELVES• SHELVES TO BE ADJUSTABLE C/W S.S. PILASTER STRIP AND CLIPS

MILLWORK HARDWARELOCKS:HAFELE CYLINDER MODULE SYSTEMVERTICAL INSTALLATION DOOR LOCK MODEL: 235.08.358 P516

PULLS:RICHELIEU: CONTEMPORARY ALUMINUM EDGE PULL - 9898LENGTH: 212mm TYPICAL, 436mm AT FULL HEIGHT CABINETS, 96mm AT TV CABINET BRUSHED BLACK FINISHREFER TO ELEVATIONS & DETAILS

HEAVY DUTY HINGES:PRODUCT: CONCEALED HINGE (HEAVY DUTY)MANUFACTURER: HAFELE MODEL: SUGATSUNE J95DESCRIPTION: HEAVY DUTY, FULL OVERLAY, SCREW MOUNT, NICKEL-PLATED; (2) HINGES CAPABLE OF SUPPORTING 55LBSINSTALLATION: PROVIDE (4) HINGES FOR EACH FULL HEIGHT STORAGE CABINET DOOR

GROMMETS:RICHELIEU: METAL GROMMET - 20694170SIZE: 75mm DIAMETERSTAINLESS STEEL FINISHREFER TO ELEVATIONS & DETAILS

MONITOR ARMS:MANUFACTURER: ESIMODEL: EDGE SINGLE MONITOR ARMFINISH: EDGE-BLK BLACKREFER TO ELEVATIONS & DETAILS

DIVISION 07 – THERMAL AND MOISTURE PROTECTION

07 21 16 BLANKET INSULATION

INTERIOR WALL INSULATION: • BATT AND BLANKET MINERAL FIBRE INSULATION• THICKNESS: AS NOTED IN DRAWINGS• PRODUCT: ROCKWOOL SAFE'n'SOUND, OR APPROVED EQUAL

DIVISION 08 - OPENINGS

08 11 00 METAL DOORS AND FRAMES: INTERIOR DOOR FRAME• 16 GAUGE HOLLOW METAL, 2” FACE PROFILE:• HOLLOW METAL FRAME, PAINTED• PROVIDE SHOP DRAWINGS FOR CONSULTANT REVIEW• STANDARD OF ACCEPTANCE: ALLMAR STANDARD SERIES HOLLOW METAL FRAME• REFER TO DOOR SCHEDULE

08 14 16 FLUSH WOOD DOORS • SOLID PARTICLEBOARD CORE WITH DENISTY OF 28-32lbs PER CUBIC FOOT• 1/8" THICK VENEER STILE, TOP AND BOTTOM RAILS, LONGITUDINALLY LAMINATED BY HOT PRESSING W/ TYPE 1 STRUCTURAL GLUE• WOOD VENEER FACES (MAPLE VENEER, 2 PLY PLYWOOD) GLUED TO COMPOSITE CROSS-BAND. VENEER TO MATCH ADJACENT DOOR. MANUFACTURER TO CONFIRM SPECIES PRIOR TO FABRICATION. • STAIN TO MATCH EXISTING DOORS• REFER TO DOOR SCHEDULE

QT-1 QT-1

QT-1 QT-1

QT-1 QT-1

QT-1 QT-1

QT-1 QT-1

QT-1 QT-1

RSF-1 RCB-1

QT-1 QT-1

QT-1 QT-1

QT-1 QT-1

RF-1 RCB-1

EX EX

QT-1 QT-1

RSF-1/RST-1 RCB-1/ -

EX EX

TOILET AND BATH ACCESSORIES

WALL MOUNTED SHELFMANUFACTURER: BOBRICKPRODUCT: B-296 X 18 STAINLESS STEEL SHELF DESCRIPTION: 18-GAUGE (1.2MM) SHELF, TYPE 304 STAINLESS STEEL, SATIN FINISH. 3/4″ (19MM) RETURN EDGE; FRONT EDGE IS HEMMED FOR SAFETY. BRACKETS ARE 16-GAUGE (1.6MM).SIZE: 18" L X 6" WIDE

WALL PROTECTIONCORNER GUARDS-STAINLESS STEEL (CG-1)MANUFACTURER: FROSTPRODUCT: MODEL 1117 CORNER GUARDDESCRIPTION: 18 GAUGE; TYPE 304 STAINLESS STEELFINISH: NO. 4 BRUSHED FINISHSIZE: 4”D X 4” W X 40” HWARRANTY: 1 YEAR WARRANTYINSTALLATION METHOD: FULL LENGTH SELF ADHESIVE BACKING AS PER MANUFACTURERS RECOMMENDATIONS AND APPLICATION METHODS

DIVISION 10 – MISCELLANEOUS SPECIALTIES

MAGNETIC BACKPAINTED GLASS MARKERBOARD (MBG-1)MANUFACTURER: GOLDRAYPRODUCT: FULLY TEMPERED LOW IRONDESCRIPTION: MINIMUM THICKNESS 5/16” (8MM) COMPRISED OF ONE LAYER OF ¼” (6MM) GLASS PERMANENTLY BONDED TO A PARAMAGNETIC MATERIAL ON THE UNEXPOSED SURFACE.COLOUR: DECORATOR'S WHITESIZE: REFER TO ELEVATIONSEDGE: FLAT POLISHEDACCESSORIES: Z-BAR HANGER CLIPS, NO VISIBLE MOUNTING HARDWARE. STRUCTURALMOUNTING HARDWARE CONCEALED BEHIND THE GLASS.

WINDOW COVERINGSMANUAL ROLLER BLACKOUT SHADES (RS-1)PRODUCT: ALTEX SUNPROJECT- TEXOPAQUE ECO 6100 BLACKOUT ROLLER SHADESSTANDARD WIDTH: 299.7 CM/ (118”)STANDARD LENGTH: 27.4 M/ (30 L/YD.)WEIGHT: 12.14 OZ. /YD.FABRIC THICKNESS: 0.356MM (0.014”)FABRIC COMPOSITION: 100% POLYESTER WITH ACRYLIC BACKING- PVC FREE; -FABRIC TO BE SAME COLOR BOTH SIDES OF SHADE.FIRE CLASSIFICATION: NFPA 701; CAN/ ULC-S 109-03; NFPA 101 CLASS A RATING; IBC SECTION 803 1.1 CLASS A RATINGBACTERIAL AND FUNGAL RESISTANCE: ASTM E 2180, ASTM G21SOLAR HEAT CONTROL PROPERTIES- IN ACCORDANCE WITH ASHRAE STANDARD 74-1988ENVIRONMENTAL: MEETS GREENGUARD GOLD; RECYCLABLE; LEAD FREE FABRICCASSETTE: ALUMINUM FINISH; SQUARE CASSETTE; CHAIN FOR OPERATINGWARRANTY: 1 YEAR WARRANTY

QT-1 QT-1

N/ARS-1N/A

RS-1

RS-1

RS-1

RS-1

RS-1

RS-1

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/AN/A

N/A

08 71 00 DOOR HARDWARE• ALL HARDWARE TO BE COMMERCIAL GRADE HARDWARE• PROVIDE THRESHOLDS, WEATHERSTRIPPING, SEALS AND DOOR GASKETS AS REQUIRED• PROVIDE SMALL FORMAT INTERCHANGABLE CORES (SFIC)• PROVIDE MAINTENANCE TOOLS AND ACCESSORIES SUPPLIED BY HARDWARE COMPONENT MANUFACTURER.• ALL KEYING TO BE COMPLETED BY CONTRACT ADMINISTRATOR • ALL HANDLES TO BE LOCKABLE LEVER TYPE HANDLES, UNLESS NOTED OTHERWISE. REFER TO ELEVATION. • ACCEPTABLE SUPPLIERS: SCHLAGE, SATIN CHROMIUM FINISH OR EQUAL•  EXACT DOOR HARDWARE TO BE DETERMINED BY THE DOOR HARDWARE SUPPLIER AND APPROVED BY CONTRACT ADMINISTRATORS. PROVIDE SHOP DRAWINGS. • 3 HINGES TO MATCH EXISTING • KICK PLATES: 12" ROCKWOOD KICKPLATES - K1050 12” US32D RO

BRUSHED STAINLESS FINISH• PUSH PLATES: 111 x 70C  US32 RO• ROCKWELL 461 US26D RO

ROOM PARTITIONSPRODUCT: LINKING PANELS OR APPROVED EQUALMANUFACTURER: GLOBAL CONTRACTCOLOUR: PANELS & FRAMES TO BE IN DESIGNER WHITE (DWT)SIZE: EQUAL PANELS TO DIVIDE DORM G18 - SITE CONFIRM DIMENSIONS. REFER TO RENOVATION PLAN. 2 ADDITIONAL PANELS AT 5'-0" WIDE FOR PRIVACY AT BEDS.ALL PANELS TO BE 66" HIGH.LOCATION: DORM G-18PARTITIONS TO BE MOVABLE (NOT FIXED). PROVIDE ALL FRAMES, CONNECTORS, CASTORS AND LEVELERS.SPECIAL: SUBSTITUTES CAN BE PROPOSED TO CONSULTANT FOR REVIEW AND APPROVAL.

DINING TABLE BASEPRODUCT: MANHATTAN MNT2 DOUBLE COLUMN 'T' BASE OR APPROVED EQUALW/ CUSTOM QUARTZ (QZ-1) TOPMANUFACTURER: SPECBASE COLOUR: BLACK SIZE: 42" X 60" LOCATION: KITCHEN G-08SPECIAL: SUBSTITUTES CAN BE PROPOSED TO CONSULTANT FOR REVIEW AND APPROVAL.

KITCHEN ACCESSORIES

MAGNETIC KNIFE HOLDERMANUFACTURER: OMCANPRODUCT: MAGNETIC KNIFE BAR 23592FINISH: STAINLESS STEEL SIZE: 17.75" X 1.75"

STAINLESS INTEGRAL KITCHEN SINK• 16GA S.S. T304#4 MINIMUM - ALL COVED WELDED INTEGRAL INTO COUNTERTOP - WELDS CLEANED AND POLISHED TO BLEND WITH S.S. TOP.• SEE SIZES ON DRAWING• 3 1/2" S.S. STRAINER ASSEMBLIES C/W 1 1/2" DRAIN

SOLID SURFACE COUNTERTOPS (SSC-1)MANUFACTURER: WILSONARTPRODUCT: SOLID SURFACECOLOUR: CHILLED EARTH 9228SSFINISH: MATTETHICKNESS: 1/2” THICKSHEET SIZE: 30” W X 144”FIRE PERFORMANCE: CAN/ULC-S102.2; SMOKE DEVELOPED VALUE 5WARRANTY: 10 YEAR LIMITED PRODUCT WARRANTYENVIRONMENTAL: GREENGUARD INDOOR AIR QUALITY CERTIFIED; NSF CERTIFIED.

QUARTZ COUNTERTOPS (QZ-1)MANUFACTURER: HANSTONE PRODUCT: QUARTZCOLOUR: TOFINOFINISH: POLISHED SURFACE ON ALL EDGES; NON-PORUS, SCRATCH RESISTANT; MOULD RESISTANT; CORNERS TO BE ROUNDED. THICKNESS: ½” THICKCOMPRESSION STRENGTH: ASTM C170SURFACE BURNING CHARACTERISTICS: CLASS A; ASTM E84; FLAME SPREAD INDEX-10 OR LESS; ENVIRONMENTAL: GREENGUARD CERTIFIED, NSF CERTIFIEDWARRANTY: 10 YEAR COMMERCIAL WARRANTYLOCATION: CUSTOM COMMON AREA DINING TABLETOP

SOLID COMPACT LAMINATE (PLAM-1)MANUFACTURER: FORMICAPRODUCT: COMPACT STRUCTURAL LAMINATE, GRADE S6COLOUR: AGED ASH 8844TEXTURE: MATTETHICKNESS: ½”SURFACE BURNING CHARACTERISTICS: CLASS B; ASTM E84WARRANTY: 1 YEARLOCATION: MILLWORK VERTICAL SURFACES AND EXPOSED CABINET BASES WHERE POSSIBLE.SPECIAL: RUN WOODGRAIN IN HORIZONTAL ORIENTATION

SOLID COMPACT LAMINATE (PLAM-2)MANUFACTURER: FORMICAPRODUCT: COMPACT STRUCTURAL LAMINATE, GRADE S6COLOUR: STORM SOLIDZ 3505TEXTURE: MATTETHICKNESS: ½”SURFACE BURNING CHARACTERISTICS: CLASS B; ASTM E84WARRANTY: 1 YEARLOCATION: MILLWORK VERTICAL SURFACES AND EXPOSED CABINET BASES WHERE POSSIBLE.

STAINLESS STEEL COUNTERTOPS (SS-1) – KITCHENTYPICAL COUNTERTOPS: 16 GAUGE TYPE T304 #4 STAINLESS STEEL COMPLETE WITH MARINE EDGE LIP AND FRONT AND SIDES (TYPICAL)KITCHEN SINKS: KITCHEN COUNTERTOPS TO RECEIVE INTEGRAL STAINLESS STEEL SINK INTO COUNTERTOP

EXISTING WALL & CEILING FINISHES:• PREPARE TO RECEIVE NEW PAINT FINISH. REMOVE ALL LOOSE OR DAMAGEDMATERIALS, RAKE CRACKS TO A MINIMUM DEPTH OF 1/8” AND SKIM-COAT WITHGYPSUM-BASED COMPOUND TO PROVIDE SMOOTH, PAINTABLE FINISH. APPLY INMULTIPLE COATS AS REQUIRED

FLOORINGRESILIENT SHEET FLOORING (RSF-1)PRODUCT: ARMSTRONG FLOORING HETEROGENEOUS SHEET FLOORINGSTYLE: CORLONCOLOUR: 88702 WHITE CLIFFSCONSTRUCTION: INLAID; TRUE THROUGH-PATTERN WEAR LAYERTHICKNESS: 2.0 MM -PRODUCT; 1.27 MM WEAR LAYERROLL WIDTH: 6FT (1.83M)COORDINATED WELD ROD: ARMSTRONG STONE GREY #WS168BACKING: TEXTURED TYPE 1, CLASS A BACKINGLIGHT REFLECTANCE: 45-49%SMOKE DENSITY: ASTM E 662FACTORY FINISH: COMMERCIAL UV CURED POLYURETHANE COATINGWARRANTY: 5 YEAR COMMERCIAL RESILIENT LIMITED WARRANTYSUSTAINABILITY: LOW VOC; ENVIRONMENTAL PRODUCT DECLARATION, FLOORSCORE CERTIFICATIONINSTALLATION METHOD: FULL SPREAD; AS PER MANUFACTURERS RECOMMENDATIONS

DOORS & FRAMES:•FINISH EXISTING HOLLOW METAL FRAMES & DOORS AS PER MANUFACTURER’S PUBLISHED INSTALLATION GUIDE WITH ONE COAT PRIMER AND TWO COATS OF A HIGH-QUALITY LATEX, SEMIGLOSS FINISH PAINT. STANDARD OF ACCEPTANCE: PRIMER: SHERWIN WILLIAMS PRO-CRYL UNIVERSAL PRIMER; TOP COAT: SHERWIN WILLIAMS SOLO ACRYLIC INTERIOR/EXTERIOR LATEX (SUBMIT COLOUR SAMPLE TO CONSULTANT FOR APPROVAL).

EPOXY PAINT (EPT-1): MANUFACTURER: STONGLAZEPRODUCT: STONHARD, INC.; STONGLAZE VSR. STONGLAZE VSR AS DISTRIBUTED BY STONHARD DIVISION, RPM CANADA, IS A NOMINAL 10-12 MIL (250 TO 300 MICRON) THICK SYSTEM COMPRISED OF A TWO-COMPONENT, GENERAL SERVICE, POLYAMIDE EPOXY PRIMER AND A TWO-COMPONENT, HIGH PERFORMANCE, HIGH SOLIDS, EPOXY GLAZE COATING. HIGH GLOSS FINISH.DESCRIPTION: RESINOUS WALL SYSTEM INCLUDES A PENETRATING, TWO-COMPONENT, EPOXY POLYAMIDE PRIMER AND A TWO-COMPONENT, HIGH PERFORMANCE, HIGH SOLIDS, PIGMENTED EPOXY GLAZE COATING. COLOUR: CUSTOM COLOR TO MATCH BENJAMIN MOORE #OC-17 WHITE DOVE.HARDNESS: 80-85 (ASTM D-2240/ SHORE D DUROMETER)BOND STRENGTH: >300 PSI (ASTM D-7234)IMPACT RESISTANCE: EXCEEDS 80 IN. LBS (ASTM D-2794) (NO CRACKING, CRAZING OR LOSS OF ADHESION)ABRASION RESISTANCE: 0.08 GM MAX WEIGHT LOSS (ASTM D-4060, TABER ABRADER CS-17 WHEEL)MOCKUP: APPLY FULL-THICKNESS MOCKUPS ON 48-INCH- (1200-MM-) SQUARE WALL AREA SELECTED BY CONTRACT ADMINISTRATOR.

SPECIFICATION NOTES:

ALL FINISHES LISTED ON THE DRAWINGS ARE THE SELECTED PRODUCTS OF THE WINNIPEG FIRE PARAMEDIC SERVICE BASED ON INDUSTRY STANDARDS, DURABILITY, QUALITY, AND MAINTENANCE PURPOSES FOR A HEAVY USE 24/7 ENVIRONMENT. HOWEVER ALTERNATE FINISHES AND/OR PRODUCTS MAY BE CONSIDERED AS AN APPROVED SUBSTITUTE IN ACCORDANCE WITH MATERIALS MANAGEMENT POLICY B7 AS PER THE TENDER DOCUMENTS.

INTERIOR RENOVATIONS

2'-8

1/2

"S

ILL

HE

IGH

T

2'-8

1/2

"S

ILL

HE

IGH

T

2'-8

1/2

"S

ILL

HE

IGH

T

3'-3

1/4

"S

ILL

HE

IGH

T

4'-1

"3'-10 1/2" 2'-7 1/2"

4'-1

"

3'-3

1/4

"S

ILL

HE

IGH

T

4'-5

1/2

"

9'-10 1/2"7'-4"

4'-5

1/2

"

5'-9"

4'-5

1/2

"

W1 W2 W3 W4 W5

QUANTITY: 1 QUANTITY: 1 QUANTITY: 1 QUANTITY: 1 QUANTITY: 6

NOTE: SITE CONFIRM ALL EXISTING WINDOW DIMENSIONS FOR NEW BLINDS. REFER TO SPECS & ROOM SCHEDULE FOR BLIND TYPES.

WINDOW SCHEDULE

BID OPPORTUNITY 280-2020

DOOR SCHEDULE

DOOR TYPE 1 FRAME TYPE 1

7'-0

"

3'-4

"

2" T

YP

3'-0" 3'-0"

7'-0

"

GENERAL NOTES:

THESE DRAWINGS SHALL NOT BE SCALED.

THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY ONESELF ALL DIMENSIONS, DATUM, AN DETAILED INFORMATION SHOWN ARE CORRECT.

THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGS FOR DUCT, PIPE & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS.

ALL OPENINGS THROUGH FIRE ASSEMBLIES ARE TO BE FIRESTOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER.

ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITH MANUFACTURER'S SPECIFICATIONS & APPLICABLE CODES.

THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTING CONSTRUCTION AFFECTED BY DEMOLITION AND THE REMOVAL OF ALL ITEMS FORMING PART OF THE RENOVATION WORK.

WHERE NEW FLOORING AND BASE IS TO BE INSTALLED IN EXISTING AREAS (REFER TO FLOOR PLAN AND ROOM SCHEDULE) THE EXISTING FLOORING SURFACE AND BASE MUST BE REMOVED, UNLESS OTHERWISE NOTED. ALL FLOOR SURFACES SHALL BE PREPARED IN ACOORDANCE TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF NEW FLOOR.

WHERE PAINTING OF EXISTING WALLS & CEILINGS IS INDICATED ON THE ROOM SCHEDULE, THESE WALLS MUST BE CLEANED OF ANY EXISTING WALL COVERING, PATCHED & PREPARED TO ACCEPT NEW PAINT, UNLESS OTHERWISE NOTED.

ALL EXISTING FURNITURE, EQUIPMENT (INCLUDING GYM EQUIPMENT), AND WALL MOUNTED ITEMS/ ARTWORK/ MAPS/ EXIT PLANS ARE TO BE REMOVED AND REINSTALLED BY THE CITY OF WINNIPEG'S MOVERS (TO BE STORED IN THE APPARATUS ROOM OR A STORAGE CONTAINER AS REQ'D).

EMERGENCY LIGHTING TO BE REPLACED, REFER TO ELECTRICAL FOR SCOPE OF WORK.

ALL MISCELLANEOUS FLOOR MOUNTED ELECTRICAL TO BE REMOVED & REINSTALLED FOR FLOORING INSTALLATION.

ALL MECHANICAL WALL VENTS/GRILLES TO BE REMOVED & REINSTALLED FOR PAINTING.

ALL EXISTING DOORS ARE TO BE CUT DOWN OR ADJUSTED AS REQUIRED TO ACCOMMODATE NEW FLOORING THICKNESS. PATCH & MAKE GOOD ALL DOORS.

ALL FIRE EXTINGUISHERS TO BE REMOVED AND REINSTALLED FOR PAINTING.

WARNING:ASBESTOS MAY BE PRESENT BEHIND WALLS CEILING SPACE & FLOORS. IF ASBESTOS OR ANY HAZARDOUS MATERIAL IS FOUND STOP WORK IMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS PH: 204-986-2351.

Page 7: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

UP

SP

K

ROOM

G-10

CLEANING

ROOM

G-21

DRYING

HOSE TOWER

G-20

ROOM

G-22

STORAGE

VESTIBULE

G-01

DORMITORY

G-18

ROOM

G-17

LOCKER WASHROOM

G-09

WOMEN'S

ROOM

G-11

STATIONARY

SHOWER

G-15

WASHROOM

G-16

MEN'S

CORRIDOR

G-13

CORRIDOR

G-03

KITCHEN

G-08LOUNGE

G-07

OFFICE

G-06

CAPTAIN'S

OFFICE

G-05

LIEUTENANT'S

ROOM

G-23

CONTROL

RECEPTION

G-02

ROOM

G-14

MECHANICAL

VESTIBULE

G-19

ROOM

G-12

APPARATUS

SPK

SP

K

SP

K

SP

K

SP

K

ROOM

G-04

PHONE

UP

SP

K

ROOM

G-10

CLEANING

ROOM

G-21

DRYING

HOSE TOWER

G-20

ROOM

G-22

STORAGE

VESTIBULE

G-01

DORMITORY

G-18

ROOM

G-17

LOCKER WASHROOM

G-09

WOMEN'S

ROOM

G-11

STATIONARY

SHOWER

G-15

WASHROOM

G-16

MEN'S

CORRIDOR

G-13

CORRIDOR

G-03

KITCHEN

G-08LOUNGE

G-07

OFFICE

G-06

CAPTAIN'S

OFFICE

G-05

LIEUTENANT'S

ROOM

G-23

CONTROL

RECEPTION

G-02

ROOM

G-14

MECHANICAL

VESTIBULE

G-19

ROOM

G-12

APPARATUS

SPK

SP

K

SP

K

SP

K

SHOWER

DN

W/C

M-02

STAIRHALL

M-03

RESCUE

M-04

WATER

DORMITORY

M-01

HOSE TOWER

G-20

SPK

SPK

UP

FE

SHOWER

DN

W/C

M-02

STAIRHALL

M-03

RESCUE

M-04

WATER

DORMITORY

M-01

HOSE TOWER

G-20

SPK

SPK

1

2

3

45

6

7

8

9

10

(TYP)

11

13

14

15

1617

18

19

--1S

14 X 4

20 X 4

20

(TYP)

21

SK - 1

DW - 1

WM - 1

10Ø

LAV - 1LAV - 1

(TYP. of 3)

22 2223GI - 1

1

12

LAV - 1 22

A. CONFORM TO APPLICABLE CODE FOR DEMOLITION WORK, DUST CONTROL, PRODUCTS REQUIRING ELECTRICAL DISCONNECTION OR RECONNECTION.

B. CONFORM TO APPLICABLE REGULATORY PROCEDURES WHEN DISCOVERING HAZARDOUS OR CONTAMINATED MATERIALS.

C. CLOSE OPENINGS IN EXTERIOR SURFACES TO PROTECT EXISTING WORK FROM WEATHER AND EXTREMES OF TEMPERATURE AND HUMIDITY.

D. PROVIDE, ERECT, AND MAINTAIN TEMPORARY BARRIERS WHERE NEEDED TO CONTAIN CONSTRUCTION DEBRIS AND DUST. PROVIDE A MINIMUM MERV 8 FILTRATION ON EXISTING INLETS AND RETURN AIR DUCTS AND SYSTEMS.

E. PROTECT EXISTING MATERIALS, EQUIPMENT, AND SYSTEMS WHICH ARE NOT TO BE DEMOLISHED.F. CONDUCT DEMOLITION TO MINIMIZE INTERFERENCE WITH OCCUPIED BUILDING AREAS.G. DISCONNECT, REMOVE, CAP, AND IDENTIFY DESIGNATED UTILITIES WITHIN DEMOLITION AREAS.H. REMOVE, CUT, AND PATCH WORK IN A MANNER TO MINIMIZE DAMAGE AND TO PROVIDE MEANS OF RESTORING

SYSTEMS TO ORIGINAL CONDITION.I. CAREFULLY DISMANTLE EXISTING MECHANICAL EQUIPMENT TO BE REMOVED OR RELOCATED. TEMPORARILY

DISCONNECT, REMOVE, AND REINSTALL EXISTING EQUIPMENT, PIPING, DUCTWORK, CONDUIT, LIGHT FIXTURES, AND SIMILAR ITEMS, WHICH INTERFERE WITH THE NEW INSTALLATION AFTER COMPLETION OF NEW WORK OR OF EXISTING INSTALLATIONS TO BE DEMOLISHED. STORE EQUIPMENT AND MATERIALS ON THE PREMISES AS DIRECTED BY THE OWNER.

J. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. REMOVE DEMOLISHED MATERIALS FROM SITE EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. UPON COMPLETION OF WORK, LEAVE AREAS IN CLEAN CONDITION.

K. ALL USABLE SALVAGED EQUIPMENT AND MATERIALS SHALL REMAIN THE PROPERTY OF THE OWNER UNLESS SPECIFICALLY NOTED OTHERWISE.

L. FIRESTOP ALL MECHANICAL PENETRATIONS THROUGH FIRE-RATED FLOOR AND WALL ASSEMBLIES WHERE PIPES OR DUCTS WERE REMOVED. SEE ARCHITECTURAL DRAWINGS FOR LOCATION AND TYPE OF RATINGS.

M. THE ABANDONMENT OF EXISTING EQUIPMENT AND MATERIAL IN PLACE IS NOT ACCEPTABLE. ALL REDUNDANT SERVICES ARE TO BE REMOVED BACK TO ACTIVE MAINS, WHICH SHALL THEN BE CAPPED AT EXISTING POINT OF CONNECTION.

N. FIRESTOP ALL MECHANICAL PENETRATIONS THROUGH FIRE-RATED FLOOR AND WALL ASSEMBLIES. SEE ARCHITECTURAL DRAWINGS FOR LOCATION AND TYPE OF RATINGS.

O. THE CONTRACTOR SHALL SIZE AND COORDINATE PLUMBING VENTING AND COORDINATE DOMESTIC WATER AND SANITARY PIPE ROUTING. THE CONTRACTOR SHALL ALLOW FOR THE POSSIBILITY OF INTERFERENCES AND SHALL RESOLVE WITH OTHER TRADES ON SITE. ANY CHANGES TO THE DESIGN INTENT REQUIRE APPROVAL BY THE ENGINEER.

P. ALL NEW CORING FOR PLUMBING SERVICES SHALL BE DONE BY MECHANICAL CONTRACTOR. COORDINATE WITH ALL OTHER TRADES.

Q. CONTRACTOR SHALL SCAN FOR REBAR AND CONDUIT AND PROVIDE RESULTS OF SCAN IN WRITING TO OWNER PRIOR TO CORING OR DRILLING IN ANY CONCRETE WALL OR FLOOR.

R. COORDINATE FINAL THERMOSTAT INSTALLATION HEIGHT AND DISTANCE FROM DOOR WITH ARCHITECT.

MECHANICAL GENERAL NOTES

x architecture inc.120 Fort Street, Suite 103 Winnipeg, Manitoba R3C 1C7 204 318 2010

Seal

Engineer

Project

Sheet Title

NO. DATE REVISION / ISSUANCE

SheetProject No .

Date

Architect

19089A

BID OPPORTUNITY 280-2020

799 LILAC STREET

20-06-09

FLOOR PLANS - MECHANICAL

WINNIPEG FPS FIRE STATION #13INTERIOR RENOVATIONS

M2.1

16 PROVIDE DOMESTIC WATER AND SANITARY ROUGH IN FOR DISHWASHER AND CONNECT TO PREVIOUSLY DEMOLISHEDDISHWASHER PIPING. CONNECT TO SINK DRAIN WITH CONNECTED DISHWASHER CONNECTION. CONTRACTOR TO ENSUREPIPING IS INSTALLED NEATLY WITHIN OPEN CABINETS.

17 NEW RANGE HOOD ABOVE ELECTRIC STOVE (PROVIDED BY OTHERS). PROVIDE DUCT CONNECTION FOR RANGE HOODOPERATION. DUCTING SHALL RUN TIGHT TO WALL AND EXIT THROUGH HOOD. HOOD SHALL BE PREMANUFACTUREDPAINTED STEEL, SUITABLE FOR INSTALLATION ON A PITCHED SHINGLED ROOF, COMPLETE WITH BACKDRAFT DAMPERAND BIRD SCREEN. COORDINATE HOOD INSTALLATION WITH GENERAL CONTRACTOR. INSULATE RANGE HOOD EXHAUSTDUCTING FOR ENTIRE LENGTH WITHIN ATTIC.

18 INSTALL EXISTING HUMIDISTAT ON WALL. EXTEND AND MODIFY EXISTING WIRING AS REQUIRED. COORDINATE ANYREQUIREMENTS WITH ELECTRICAL.

19 INSTALL EXISTING CO MONITOR ON WALL. INSTALL MONITOR IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS ANDCODE REQUIREMENTS. COORDINATE INSTALLATION WITH ELECTRICAL CONTRACTOR AND ENSURE ANY REQUIREDINTERLOCKS AE FUNCTIONAL.

20 PROVIDE NEW GRILLE MOUNTED WITHIN CABINET TOEPLATE. CONNECT TO EXISTING DUCT. MODIFY AND EXTEND ASREQUIRED TO RUN WITHIN TOESPACE OF CABINET TO GRILLE.

21 REINSTALL ALL SUPPLY AND RETURN GRILLES AS REQUIRED AFTER CONSTRUCTION HAS BEEN COMPLETED. TYPICALALL.

22 PROVIDE NEW HANDS FREE ELECTRONIC FAUCET FOR EACH LAVATORY. PROVIDE NEW CHROME PLATED COPPERSUPPLY PIPING FROM VALVE STOP TO NEW MIXING VALVE AND TO FAUCET. LOCATE MIXING VALVE AND FAUCETCONTROLLER NEATLY BELOW LAVATORY, TIGHT TO WALL, OUT OF VIEW. LOOSE EQUIPMENT OR WIRING IS NOTACCEPTABLE.

23 PROVIDE NEW GREASE INTERCEPTOR BELOW KITCHEN SINK. INSTALL AS PER MANUFACTURERS GUIDELINES ANDENSURE CLEARANCE IS MAINTAINED FOR ACCESS TO COVER.

1 EXISTING WASHROOM FIXTURES AND TRIM TO REMAIN UNLESS OTHERWISE NOTED. DEMOLISH EXISTING LAVATORYFAUCET(S) AND PIPING BACK TO VALVE STOPS. LAVATORIES TO RECEIVE NEW FAUCET DURING RENOVATION.

2 DEMOLISH EXISTING DOMESTIC WATER AND SANITARY CONNECTIONS TO DISHWASHER. RETAIN CONNECTIONS FORFUTURE DISHWASHER INSTALLATION DURING RENOVATION.

3 DEMOLISH EXISTING EXHAUST SYSTEM SERVING GRILLE ENTIRELY.

4 REMOVE EXISTING RANGE HOOD AND TURN OVER TO OWNER.

5 DEMOLISH EXISTING SINK AND ASSOCIATED TRIM. DEMOLISH DOMESTIC WATER AND SANITARY PIPING TO WITHIN WALLCAVITY. PIPING SHALL BE EXTENDED TO SERVE NEW SINK. REFER TO RENOVATION PLAN.

6 DEMOLISH EXISTING SERVICE SINK AND ASSOCIATED TRIM. DEMOLISH SANITARY PIPING BACK TO WITHIN CRAWLSPACE.PIPING TO BE EXTENDED TO NEW WASHING MACHINE BOX. REFER TO RENOVATION PLAN. COORDINATE FLOOR PATCHINGWHERE EXISTING PIPING WAS REMOVED WITH GENERAL CONTRACTOR.

7 DEMOLISH EXISTING FLOOR MOUNTED GRILLE. DUCTWORK TO REMAIN FOR USE IN CONSTRUCTION. REFER TORENOVATION PLAN.

8 DEMOLISH EXISTING URINAL. DEMOLISH DOMESTIC WATER AND SANITARY PIPING SO THAT IT IS FLUSH WITH WALL.PROVIDE CHROME PLATED COVER PLATES.

9 REMOVE EXISTING CO MONITOR. MONITOR TO BE RELOCATED DURING CONSTRUCTION. REFER TO RENOVATION PLAN.

10 REMOVE EXISTING HUMIDISTAT. HUMIDISTAT TO BE RELOCATED DURING CONSTRUCTION. REFER TO RENOVATION PLAN.

11 REMOVE EXISTING FLOOR MOUNTED SUPPLY GRILLE TO ALLOW FOR INSTALLATION OF NEW FLOORING. REINSTALLGRILLE AFTER FLOORING IS COMPLETE. SEAL OFF DUCTWORK DURING CONSTRUCTION, ASSOCIATED FURNACE SHALLBE OFF WITH ALL DUCTWORK COVERED DURING DEMOLITION AND RENOVATION PHASE. TYPICAL ALL.

12 EXISTING EXHAUST FAN AND ASSOCIATED DUCTING TO REMAIN.

13 PROVIDE NEW RECESSED WASHING MACHINE BOX. EXTEND AND MODIFY EXISTING DOMESTIC WATER WITHIN WALLCAVITY TO SUIT NEW FIXTURE LOCATION. SANITARY PIPING SHALL DROP CONCEALED WITHIN WALL AND CONNECT INTOEXISTING WITHIN CRAWLSPACE.

14 ALUMINUM DRYER DUCT TO RUN TIGHT TO WALL AND TERMINATE AT ROOF THROUGH HOOD. HOOD SHALL BEPREMANUFACTURED PAINTED ALUMINUM ROOF HOOD, SUITABLE FOR INSTALLATION ON A PITCHED SHINGLED ROOF,COMPLETE WITH BACKDRAFT DAMPER AND BIRD SCREEN. COORDINATE HOOD INSTALLATION WITH GENERALCONTRACTOR. INSULATE DRYER DUCTING FOR ENTIRE LENGTH WITHIN ATTIC. ALLOW FOR FLEXIBLE DUCT CONNECTIONFROM DRYER DUCTING TO DRYER TERMINATION.

15 PROVIDE NEW TRIM FOR INTEGRAL KITCHEN SINK. EXTEND AND MODIFY EXISTING DOMESTIC WATER PIPING ASREQUIRED TO SUIT NEW LOCATION. PLUMBING PIPING SHALL RUN CONCEALED WITHIN WALL AND ONLY PENETRATEDIRECTLY BELOW NEW SINK WITH NEW CHROME PLATED VALVE STOPS WITH VALVE WHEEL. SANITARY PIPING SHALLDROP WITHIN MILLWORK AFTER CONNECTION TO GREASE INTERCEPTOR TO CRAWLSPACE AND CONNECT TO EXISTING.EXTEND AND MODIFY VENTING AS REQUIRED.

PLUMBING FIXTURE PIPE SIZE SCHEDULE

MARK DCW DHW SANITARY VENT

DW 1 0" 0 mm 1/2" 13 mm 1 1/2" 38 mm 1 1/4" 32 mm

LAV 1 1/2" 13 mm 1/2" 13 mm 1 1/4" 32 mm 1 1/4" 32 mm

SK 1 1/2" 13 mm 1/2" 13 mm 1 1/2" 38 mm 1 1/4" 32 mm

WM 1 1/2" 13 mm 1/2" 13 mm 2" 51 mm 1 1/2" 38 mm

* FOLLOW PIPE SIZES GIVEN IN ABOVE CHART UNLESS DRAWING SHOWS DIFFERENTLY.

400 - 136 Market AvenueWinnipeg, MB R3B 0P4

T 204 453 1080

M2.1 SCALE: 1/8" = 1'-0"1 MAIN FLOOR PLAN - MECHANICAL DEMOLITION

M2.1 SCALE: 1/8" = 1'-0"2 MAIN FLOOR PLAN - MECHANICAL RENOVATION

M2.1 SCALE: 1/8" = 1'-0"3 MEZZANINE FLOOR PLAN - MECHANICAL DEMOLITION

M2.1 SCALE: 1/8" = 1'-0"4 MEZZANINE FLOOR PLAN - MECHANICAL RENOVATION

DIFFUSER & GRILLES SCHEDULE

MARK

MODEL NOTES

S 1 20x4/LBP15A/L/66/500F/D 1,2

1. EH PRICE LINEAR BAR GRILLE, NARROW SPACING, STREAMLINED BLADES.2. SUITABLE FOR INSTALLATION IN CABINET TOE PLATE.

MECHANICAL FIXTURE BASIS OF DESIGN:

SK-1: (Trim Only) T&S Brass B-0133-B, chrome plated, wall mount, pre-rinse unit, 8" wall mount mixing faucet with lever handles, 1.15 gpm spray valve, 44" flexble stainless steel hose. Chrome plated drainage piping.GI-1: Zurn GT2700-10 , 10 GPM/20 lbs grease capacity, corrosion-resistant coated fabricated steel with no-hub connections, flow diffusing baffle, integral trap, vented inlet flow control device, gas/water tight cover, certified to ASME A112.14.3 (type C) and CSA B481.1 standards.LAV-1: (Faucet Only) Delta 591T1220 hands free, battery operated faucet c/w Delta R3070-MIXLF thermostatic mixing valve. Chrome plated, 4" on center mounting, surface mount control box, 5 Year limited warranty.WM-1: Oatey Quadtro, PVC enclosure, DCW, DHW, 2" drain knockout, backflow preventor, shutoff valves with water hammer arrestors on water connections.

KEY NOTES

Certificate of Authorization

Epp Siepman Engineering Inc.

No. 4035

0 20-06-25 Issued for Construction

Page 8: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

FL01A-12b

A-14

E

A-16

d

LPN-102

1

ELECTRICAL SYMBOL NOTESTHE LIGHTING FIXTURE TYPE IS INDICATED BY UPPER CASE LETTERS AND NUMBERS.THE CIRCUIT DESIGNATION IS INDICATED BY LETTERS AND NUMBERS SEPARATED BY DASH. THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.EXAMPLE 1: LIGHTING FIXTURE TYPE "FL01" IS CONNECTED TO PANEL A, CIRCUIT 12 AND CONTROLLED BY SWITCH "b".

EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING MOUNTING.SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES DIRECTIONAL ARROWON ILLUMINATED FACE(S). THE SIGNAGE TYPE IS INDICATED BY UPPER CASE LETTERS AND NUMBERS PRECEDING THE "/". THE ASSOCIATED BATTERY BANK IS INDICATED BY UPPERCASE LETTERS AND NUMBERS FOLLOWING THE "/". THE AC CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. EXAMPLE: THE WALL MOUNTED EXIT LIGHT TYPE "EX1" WITH SINGLE FACE AND DIRECTIONAL ARROW IS CONNECTED TO BATTERY BANK "BU1" AND AC CIRCUIT 14 FROM PANEL A .

DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. EXAMPLE: SPLIT DUPLEX RECEPTACLE IS CONNECTED TO PANEL A, CIRCUIT 16 AND ONE RECEPTACLE OUTLET IS CONTROLLED BY A SWITCH.

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER. EXAMPLE:SINGLE POLE SWITCH "d" TO CONTROL LIGHTING FIXTURES INDICATED BY "d".

PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING SIDE OFRECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR DESIGNATIONCODES.KEYNOTE. SEE THE KEYED NOTES ON THAT SHEET FOR THE NOTE NUMBER INDICATED. (TYP) INDICATES THAT THE NOTE IS TYPICAL OF THE APPLICATION.

SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE A UNITTYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.

EX1/BU1

(TYP)

ELECTRICAL DRAWINGS

1P 1 POLE (2P, 3P, 4P, ETC.)

A AMPEREAC ABOVE COUNTER OR AIR

CONDITIONERACLG ABOVE CEILINGADO AUTOMATIC DOOR OPENERAF AMP FRAMEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT CIRCUIT

INTERRUPTERAHU AIR HANDLING UNITAL ALUMINUMALT ALTERNATEAMP AMPEREAMPL AMPLIFIERANNUN ANNUNCIATORAPPROX APPROXIMATELYARCH ARCHITECT, ARCHITECTURALAUX AUXILIARYAV AUDIO VISUALAWG AMERICAN WIRE GAUGE

BATT BATTERYBD BOARD BLDG BUILDINGBMS BUILDING MANAGEMENT SYSTEM

C CONDUITCAB CABINETCAT CATALOGCATV CABLE TELEVISIONCB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCKTP COOKTOPCLG CEILINGCOMB COMBINATIONCONST CONSTRUCTIONCONT CONTINUATION OR CONTINUOUSCONTR CONTRACTORCPR COPIERCTR CENTERCU COPPERC/W COMPLETE WITH

DET DETAILDISC DISCONNECTDIST DISTRIBUTIONDN DOWNDPR DAMPERDR DEDICATED CIRCUIT RECEPTACLEDS SAFETY DISCONNECT SWITCHDT DOUBLE THROWDW DISHWASHERDWG DRAWING

EC ELECTRICAL CONTRACTORELEC ELECTRIC, ELECTRICALELEV ELEVATOREM EMERGENCYEMT ELECTRICAL METALLIC TUBINGEP ELECTRIC PNEUMATICEQUIP EQUIPMENTEWC ELECTRIC WATER COOLEREXIST EXISTINGEXH EXHAUST

FIXT FIXTUREFLR FLOORFR REFRIGERATORFZ FREEZER

GC GENERAL CONTRACTORGEN GENERATORGFI GROUND FAULT CIRCUIT

INTERRUPTERGND GROUNDGYP BD GYPSUM BOARD

HORIZ HORIZONTALHT HEIGHT

HRV HEAT RECOVERY VENTILATIONHTG HEATINGHTR HEATERHV HIGH VOLTAGEHVAC HEATING, VENTILATING AND

AIR CONDITIONINGHWP HYDRONIC WATER PUMP

IC INTERRUPTING CAPACITYIG ISOLATED GROUNDINT INTERCOMIPLC INTELLIGENT PARKING LOT

CONTROLLERIR INFRAREDI/W INTERLOCK WITH

J-BOX JUNCTION BOX

KV KILOVOLTKVA KILOVOLT-AMPEREKW KILOWATTKWH KILOWATT HOUR

LOC LOCATE OR LOCATIONLT LIGHTLTG LIGHTINGLV LOW VOLTAGE

MAX MAXIMUMMC MECHANICAL CONTRACTORMC MICROWAVEMCB MAIN CIRCUIT BREAKERMDP MAIN DISTRIBUTION PANELMEC MECHANICAL CONTRACTOR

MIC MICROPHONEMIN MINIMUMMISC MISCELLANEOUSMLO MAIN LUGS ONLYMW COORDINATED IN MILLWORK

NEC NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NIC NOT IN CONTRACTNTS NOT TO SCALE

PA PUBLIC ADDRESSPF POWER FACTORPH PHASEPNL PANELPP POWER POLEPR PRINTERPT POTENTIAL TRANSFORMERPVC POLYVINYL CHLORIDE (CONDUIT)PWR POWER

QP QUADPLEX RECEPTACLEQUAN QUANTITY

R RELOCATEDRCPT RECEPTACLEREQD REQUIREDRM ROOMRMC RIGID METAL CONDUIT

SC SURFACE CONDUITSEC SECONDARYSHT SHEETSIM SIMILARS/N SOLID NEUTRALSPEC SPECIFICATIONSPKR SPEAKERSP SPARES/S STOP/START PUSHBUTTONSSTA STATION

STD STANDARDSURF SURFACE MOUNTEDSW SWITCHSYS SYSTEMTEL TELEPHONETEL/DATA TELEPHONE/DATAT-STAT THERMOSTATTV TELEVISIONTYP TYPICAL

UC UNDER COUNTERUSB USB RECEPTACLE

V VOLTVSR VOLTAGE SENSING RELAYVA VOLT-AMPERESVDT VIDEO DISPLAY TERMINALVERT VERTICALVFD VARIABLE FREQUENCY DRIVEVOL VOLUME

W WATTW/ WITHWG WIRE GUARDW/O WITHOUTWS WASHER

XFMR TRANSFORMER

∠ ANGLE@ ATΔ DELTA' FEET" INCHES# NUMBERØ PHASECL CENTER LINEPL PLATE

ELECTRICAL ABBREVIATIONS LIST

GENERAL ELECTRICAL NOTES

A. THE GENERAL NOTES AS DESCRIBED HEREIN, APPLY TO ALL DRAWINGS IN THIS PACKAGE WHERE APPLICABLE.

B. PENETRATIONS IN WALLS OR SEPARATIONS, REQUIRING PROTECTED OPENINGS SHALL BE FIRESTOPPED WITH AN APPROVED MATERIAL. REFER TO ARCHITECTURAL SPECIFICATIONS FOR PRODUCT REQUIREMENTS.

C. EXPOSED WIRING SHALL NOT BE PERMITTED. WIRING SHALL BE RECESSED IN WALL, OR WHERE WALLS ARE NOT ACCESSIBLE DUE TO WALL CONSTRUCTION (CONCRETE BLOCK, CONCRETE, BRICK, ETC), PROVIDE CONDUIT AS REQUIRED TO CONCEAL SAME.

D. REFER TO ARCHITECTURAL FLOOR PLANS, ELEVATIONS AND DETAILS, INCLUDING MILLWORK DETAILS AND SHOP DRAWINGS FOR COORDINATION OF ELECTRICAL DEVICE LOCATIONS, METHOD OF INSTALLATION & MOUNTING HEIGHTS. ARCHITECTURAL FLOOR PLANS, ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.

E. EQUIPMENT SHUTDOWN AND THE INTERRUPTION OF ANY SERVICES SHALL BE COORDINATED IN ADVANCE WITH THE BUILDING END USER AND SHALL BE KEPT TO A MINIMUM.

F. UNLESS NOTED OTHERWISE, THE CIRCUITING INDICATED ON THE DRAWINGS IS REPRESENTATIONAL ONLY. CONFIRM CIRCUITING REQUIREMENTS ON SITE.

G. CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEE PANELBOARD SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TO THE CIRCUIT BREAKER RATING AND VOLTAGE DROP REQUIREMENTS, UNLESS INDICATED OTHERWISE.

H. MINIMUM CONDUIT SIZE SHALL BE 21mm (3/4") UNLESS NOTED OTHERWISE.

I. EMPTY CONDUIT SHALL BE C/W PULL WIRE AND PLASTIC BUSHINGS.

J. ALL CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY. ALL RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.

K. ALL LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS SHALL BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE SPACES.

L. WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN INDIVIDUAL RECEPTACLE (SIMPLEX OR DUPLEX), THE RECEPTACLE SHALL BE RATED AT 20A.

M. CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ALL ELECTRICAL ITEMS SHOWN ON THE DRAWINGS, INCLUDING THE FOLLOWING, UNLESS NOTED OTHERWISE:A. TELEPHONE OUTLETS, DATA OUTLETS, FIRE ALARM DEVICES SHALL CONSIST OF A BACK BOX WITH CONDUIT STUBBED ABOVE THE ACCESSIBLE CEILING, VERIFY SIZE OF BACK BOX REQUIRED WITH DEVICE TO BE

INSTALLED. LOCATE BACK BOXES 6" FROM ADJACENT POWER RECEPTACLE INTENDED FOR COMPUTER USE.N. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE WITH GENERAL CONTRACTOR.

O. ALL LIFE-SAFETY SYSTEMS SHALL BE MAINTAINED AND OPERABLE AT ALL TIMES DURING CONSTRUCTION.

P. AS INDICATED IN THE GENERAL NOTES, DEMOLITION NOTES, AND KEYNOTES IN THIS DRAWING PACKAGE, UNLESS NOTED OTHERWISE, THE TERM "DEMOLISH" SHALL INCLUDE THE COMPLETE REMOVAL OF THE EXISTING ITEM IDENTIFIED, C/W ASSOCIATED WIRING, CONDUIT AND JUNCTION BOXES BACK TO LAST REMAINING DEVICE OR SOURCE. CIRCUITS FREED UP FROM DEMOLISHED ELECTRICAL, SHALL BECOME SPARE. REFER TO THE RENOVATION DRAWING KEY NOTES FOR FURTHER REQUIREMENTS.

Q. AS INDICATED IN THE GENERAL NOTES, DEMOLITION NOTES, AND KEYNOTES IN THIS DRAWING PACKAGE, UNLESS NOTED OTHERWISE, THE TERM "REMOVE & REPLACE" SHALL INCLUDE THE COMPLETE REMOVAL & REPLACEMENT OF THE EXISTING ITEM IDENTIFIED IN ITS CURRENT LOCATION, WITH A NEW ITEM, UTILIZING THE EXISTING OUTLET BOX AND WIRING. REFER TO THE RENOVATION DRAWING KEY NOTES FOR FURTHER REQUIREMENTS.

R. AS INDICATED IN THE GENERAL NOTES, DEMOLITION NOTES, AND KEY NOTES, UNLESS NOTED OTHERWISE, THE TERM "RELOCATE" SHALL INCLUDE THE COMPLETE RELOCATION OF THE EXISTING ITEM IDENTIFIED IN ITS CURRENT LOCATION ON THE DEMOLITION DRAWINGS, TO THE NEW LOCATION AS INDICATED ON THE RENOVATION DRAWINGS. INCLUDE ALL LABOUR AND MATERIALS TO REROUTE/EXTEND/REFEED THE EXISTING CIRCUITRY AS REQUIRED TO ACCOMMODATE THE RELOCATION. REFER TO THE RENOVATION DRAWING KEY NOTES FOR FURTHER REQUIREMENTS.

S. SITE CONFIRM ANY ELECTRICAL WITHIN AREAS OF RENOVATION REQUIRING RELOCATION TO ACCOMMODATE THE RENOVATION.

T. PROVIDE WIRE AND CONDUIT AS REQUIRED FOR CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION. MODIFY OR REPLACE AS REQUIRED.

U. PROVIDE CONDUIT AND/OR COMMUNICATIONS/DATA WIRING AS NECESSARY FOR CONTINUITY OF ANY COMMUNICATIONS/DATA SYSTEMS ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA EQUIPMENT OR DEVICES TO REMAIN AFTER DEMOLITION. MODIFY OR REPLACE AS REQUIRED.

V. PROVIDE BLANK COVERPLATES OVER ALL EXISTING UNUSED OPENINGS.

W. DRAWING RECORDS OF THE EXISTING FLOOR PLANS HAVE BEEN COMPILED FROM INFORMATION SUBMITTED BY THE OWNER AND FROM SITE OBSERVATIONS AS NOTED BY THE CONSULTANT. THE ACCURACY OF THESE DRAWING RECORDS IS LIMITED TO THE EXTENT OF KNOWN CONSTRUCTION INFORMATION.

X. DEMOLISH ALL ELECTRICAL DEVICES IN WALLS, FLOORS OR CEILINGS TO BE DEMOLISHED. CONFIRM EXTENT OF DEMOLITION WITH ALL DISCIPLINE DRAWINGS. REROUTE/EXTEND/RE-FEED EXISTING ELECTRICAL AS REQUIRED TO MAINTAIN EXISTING SYSTEMS NOT INDICATED TO BE REMOVED.

Y. REMOVE ANY UNUSED OR ABANDONED WIRING AND CONDUIT WITHIN RENOVATION AREA, INCLUDING BRANCH CIRCUIT WIRING, VOICE/DATA CABLING AND SYSTEMS CABLING TO SOURCE OF SUPPLY.

Z. WHERE EXISTING WIRING AND CONDUIT ARE RE-USED, VERIFY EXISTING CONDITIONS. MODIFY AND SUPPLEMENT EXISTING FASTENING AND SUPPORT TO MEET CODE REQUIREMENTS.

AA. CONTRACTOR SHALL CONFIRM ALL EXISTING SYSTEMS TO BE IN WORKING CONDITION PRIOR TO CARRYING OUT MODIFICATIONS. WHERE EXISTING SYSTEMS ARE NOT OPERABLE, NOTIFY THE CONSULTANT PRIOR TO CARRYING OUT WORK.

BB. ALL NEW WIRING SHALL BE CONCEALED WHERE POSSIBLE. UTILIZE ACCESSIBLE CEILING SPACE TO RUN NEW WIRING AS REQUIRED AND FISH INTO WALLS/MILLWORK.

CC. WHERE EXISTING WALLS ARE TO BE OPENED FOR INSTALLATION OF NEW WIRING, COORDINATE WITH GENERAL CONTRACTOR ROUTING OF SAME. ARRANGE AND PAY FOR ALL CUTTING/REPAIR/PATCHING AS REQUIRED.

DD. RELOCATE EXISTING LIGHT SWITCHES AS REQUIRED TO ACCOMMODATE NEW DOOR CONFIGURATIONS.

EE. RISER DIAGRAMS ARE SCHEMATIC AND REPRESENTATIONAL ONLY. LOCATIONS AND QUANTITIES OF EQUIPMENT/DEVICES/LUMINAIRES SHALL BE COORDINATED WITH THE ELECTRICAL FLOOR PLANS.

FF. WHERE REMOTE HEADS ARE INDICATED, PROVIDE ZONE SENSING AT THE ASSOCIATED BATTERY BANK TO PICK UP LIGHTING CIRCUITS WITHIN THAT AREA AS REQUIRED.

GG. OUTLETS OR EQUIPMENT SHALL BE MOVED TO ANY POINT WITHIN A 10’ RADIUS WHEN THE CONSULTANT REQUESTS RELOCATION BEFORE THE WORK HAS BEEN SUBSTANTIALLY COMPLETED, WITHOUT ADDITIONAL COST.

HT AFF  

AS NOTED

AS NOTED

12"*

47"

47"

18"

6"******

AS NOTED

SYMBOL  

                    

                    

                    

                    

DESCRIPTION  

LIGHTING  

SURFACE LIGHT

SURFACE LIGHT

RECESSED LIGHT(TYPE DENOTED)

EMERGENCY LIGHT - REMOTE HEAD

EXIT LIGHT

LIGHTING CONTROL  

SINGLE POLE SW

OCCUPANCY SENSOR(TYPE DENOTED)

RECEPTACLES  

DUPLEX RECEPT

SPECIAL RECEPT(TYPE DENOTED)

RECEPT C/W NEMA 5-20R CONFIG

RECEPT MTD IN FLOOR(DUPLEX SHOWN)

RECEPT MTD ABOVE COUNTER(DUPLEX SHOWN)

EQUIPMENT

JUNCTION BOX

HT AFF  

18"

48"***

18"

84"

18"

59"

47"

8"****

SYMBOL  

                    

                    

                    

DESCRIPTION  

DIRECT POWER CONNECTION

GENERAL ELECTRIC   

LIGHT SYMBOL INDICATES EXISTING

DASHED SYMBOL INDICATES REMOVED

KEYED NOTE(SEE SCHEDULE)

DEMOLITION NOTE(SEE SCHEDULE)

REVISION TAG

COMMUNICATION  

COMMUNICATIONS OUTLET(TYPE DENOTED)

WALL INTERCOM OUTLET

TELEPHONE

MULTIPLE SERVICE FLOOR OUTLET (TYPE DENOTED)

SPEAKER

INTERCOM STATION

FIREFIGHTER OR EMERGENCY TELEPHONE

VOLUME CONTROL

FIRE ALARM  

SMOKE DETECTOR(TYPE & CO DENOTED)

ALL DISTANCES ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS OTHERWISE NOTED. DEVICES INDICATED AT 1200mm MAY NOT BE INSTALLED WITH ANY OPERABLE PART HIGHER THAN 1200mm. DEVICES MAY BE INSTALLED IN CONCRETE MASONRY UNITS WITH THE TOP OF THE DEIVCE AT 1200mm. * DISTANCE ABOVE TOP OF DOOR

FRAME ** DISTANCE TO TOP OF EQUIPMENT OR DEVICE *** DISTANCE TO HIGHEST OPERABLE PART OF EQUIPMENT **** DISTANCE BELOW CEILING ***** DISTANCE TO BOTTOM OF DEVICE ****** DISTANCE ABOVE COUNTER"

ELECTRICAL SYMBOL LEGEND

FIRE PROTECTION REQUIREMENTS

A. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE FIRESTOPPED WITH AN APPROVED MATERIAL.

1. CONDUITS MAY PENETRATE WALLS OR PARTITIONS, PROVIDED THEY ARE FIRE-STOPPED.

2. OPENINGS FOR STEEL ELECTRICAL BOXES NOT EXCEEDING 16 SQUARE INCHES ARE PERMITTED PROVIDED OPENINGS DO NOT AGGREGATE MORE THAN 100 SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL OR PARTITION.

3. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.

B. LIGHT FIXTURES AND OTHER APPARATUS INSTALLED IN AN ACOUSTICAL CEILING GRID SHALL BE INDEPENDENTLY SUPPORTED.

C. RECESSED LIGHTING FIXTURES INSTALLED IN FIRE RATED CEILING ASSEMBLIES SHALL BE FIRE RATED FIXTURES BEARING THE ULC FIRE RATED LABEL. FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE ULC FIRE RESISTANCE DIRECTORY, AND SHALL INCLUDE A FIRE RATED ENCLOSURE INSTALLED OVER THE FIXTURE THAT MEETS THE REQUIREMENTS OF THE ULC FIRE RESISTANCE DIRECTORY.

SPECIFIC CODE NOTES

x architecture inc.120 Fort Street, Suite 103 Winnipeg, Manitoba R3C 1C7 204 318 2010

Seal

Engineer

Project

Sheet Title

NO. DATE REVISION / ISSUANCE

SheetProject No .

Date

Architect

19089A

BID OPPORTUNITY 280-2020

799 LILAC STREET

20-06-09

ELECTRICAL SYMBOLS ANDABBREVIATIONS

WINNIPEG FPS FIRE STATION #13INTERIOR RENOVATIONS

E0.1

SYMBOLS & ABBREVIATIONS E0.1 ELECTRICAL SYMBOLS AND ABBREVIATIONS

LIGHTING PLANS EL2.1 MAIN FLOOR - LIGHTING PLAN

POWER PLANS EP2.1 MAIN FLOOR - POWER PLAN

SCHEDULES E6.1 ELECTRICAL SCHEDULES

400 - 136 Market AvenueWinnipeg, MB R3B 0P4

T 204 453 1080

Certificate of Authorization

Epp Siepman Engineering Inc.

No. 4035

0 20-06-25 Issued for Construction

Page 9: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

UP

SPK

GR DW ST

MW

FR

POP

FR

TD CMCO

PHPH

PHTT

FE

WF

ROOMG-10

CLEANING

ROOMG-21

DRYING

HOSE TOWERG-20

ROOMG-22

STORAGE

VESTIBULEG-01

DORMITORYG-18

ROOMG-17

LOCKER WASHROOMG-09

WOMEN'S

ROOMG-11

STATIONARYSHOWER

G-15

WASHROOMG-16

MEN'S

CORRIDORG-13

CORRIDORG-03

KITCHENG-08 LOUNGE

G-07

OFFICEG-06

CAPTAIN'S

OFFICEG-05

LIEUTENANT'S

ROOMG-23

CONTROLRECEPTION

G-02

ROOMG-14

MECHANICALVESTIBULE

G-19

ROOMG-12

APPARATUS

SPK

SPK

SPK

SPK

SPK

ROOMG-04

PHONE

BU#

OS

OS

OS33

OS

OS

OS

OS

OS

3333

33

33

SHOWER

DN

W/CM-02

STAIRHALLM-03

RESCUEM-04

WATER

DORMITORYM-01

HOSE TOWERG-20

SPK

SPKOS

OS

A. WHERE NEW TOGGLE SWITCHES, OR DIMMER CONTROLS ARE ADJACENT EACH OTHER, PROVIDE GANGED SWITCHING TO ACCOMODATE TOTAL NUMBER OF SWITCHES, UNLESS NOTED OTHERWISE.

B. ALL MOUNTING HEIGHTS FOR LUMINAIRES ARE TO THE BOTTOM OF THE LUMINAIRE UNLESS NOTED OTHERWISE.

C. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF EXTERIOR OR INTERIOR LUMINAIRES.

D. UTILIZE SPARE/FREED UP CIRCUITS FROM DEMOLITION AS REQUIRED TO ACCOMMODATE THE ADDITIONAL CIRCUITING REQUIREMENTS IN THE RENOVATION.

E. WHERE REMOTE HEADS ARE INDICATED, PROVIDE ZONE SENSING AT THE ASSOCIATED BATTERY BANK TO PICK UP LIGHTING CIRCUITS WITHIN THAT AREA AS REQUIRED.

GENERAL NOTES

(TYP)3

SL1A-3

SL1A-3

SL1A-3

SL1A-3

RD1A-3

RD1A-3

RD1A-3

RD1A-3

RD1A-3

RD1A-3

RD1A-3

RD1A-3

RD1A-4

RD1A-4

RD1A-4

RD1A-4

RD1A-4 RD1

A-4

RD1A-2

RD1A-2

RD1A-5

RD1A-5

RD1A-7

RD1A-7

RD1A-7

RD1A-7

RD1A-7RD1

A-7

SL1A-1

SL1A-1

SL1A-1

SL1A-1

SL1A-1SL1

A-2

SL1A-2

SL1A-6

SL1A-6

SL1A-6

SL1A-6

SL1A-6

SL1A-6

SL1A-6

SL1A-7

SL1A-7

SL1A-7

SL1A-7

SL1A-7

SL1A-7

SL1A-7

SL1A-4

SL1A-4

SL1A-4

SL1A-4

SL1A-4

SL1A-2

SL1A-5

SL1A-5

SL1A-5

SL1A-4

SL1A-4

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

ELA26BU1

UC01A-3

UC01A-3

W2A-2

DT3

DT3 DT3

DT3

ELA26BU1

Pnl C Pnl B Pnl A Pnl D

BU1B-11

STORAGE ROOMG-22

DRYING ROOMG-21

HOSE TOWERG-20

APPARATUS ROOMG-12

VESTIBULEG-19

MECHANICAL ROOMG-14

STATIONARY ROOMG-11

WOMEN'S WASHROOMG-09

CLEANING ROOMG-10

MEN'S WASHROOMG-16

VESTIBULEG-01

CAPTAIN'S OFFICEG-06

LOUNGEG-07

DORMITORYG-18

LIEUTENANT'S OFFICEG-05

KITCHENG-08

LOCKER ROOMG-17 CORRIDOR

G-13

CORRIDORG-03

CONTROL ROOMG-23

1

22

RD1

RD1

UC01A-3

1

1

1

1

SL1A-8

SL1A-8

SL1A-8

SL1A-8

SL1A-8

SL1A-8 RD1

A-8RD1A-8

ELA26BU1

DT3DT3

HOSE TOWERG-20

DORMITORYM-01 W/C

M-02

STAIRHALLM-03

WATER RESCUEM-042

x architecture inc.120 Fort Street, Suite 103 Winnipeg, Manitoba R3C 1C7 204 318 2010

Seal

Engineer

Project

Sheet Title

NO. DATE REVISION / ISSUANCE

SheetProject No .

Date

Architect

19089A

BID OPPORTUNITY 280-2020

799 LILAC STREET

20-06-09

MAIN FLOOR - LIGHTING PLAN

WINNIPEG FPS FIRE STATION #13INTERIOR RENOVATIONS

EL2.1

400 - 136 Market AvenueWinnipeg, MB R3B 0P4

T 204 453 1080

1 EXISTING LIGHT FIXTURES IN THIS AREA TO REMAIN.2 EXISTING EXIT SIGNS TO BE CONNECTED TO NEW BATTERY BANK BU1.3 DEMOLISH ALL WALL SCONCES.

EL2.1 SCALE: 1/8" = 1'-0"1 MAIN FLOOR PLAN - LIGHTING DEMOLITION

EL2.1 SCALE: 1/8" = 1'-0"2 MAIN FLOOR PLAN - LIGHTING

EL2.1 SCALE: 1/8" = 1'-0"3 MEZZANINE FLOOR PLAN - LIGHTING DEMOLITION

EL2.1 SCALE: 1/8" = 1'-0"4 MEZZANINE FLOOR PLAN - LIGHTING

Certificate of Authorization

Epp Siepman Engineering Inc.

No. 4035

0 20-06-25 Issued for Construction

KEY NOTES

Page 10: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

UP

SPK

GR DW ST

MW

FR

POP

FR

TD CMCO

PHPH

PHTT

FE

WF

ROOMG-10

CLEANING

ROOMG-21

DRYING

HOSE TOWERG-20

ROOMG-22

STORAGE

VESTIBULEG-01

DORMITORYG-18

ROOMG-17

LOCKER WASHROOMG-09

WOMEN'S

ROOMG-11

STATIONARYSHOWER

G-15

WASHROOMG-16

MEN'S

CORRIDORG-13

CORRIDORG-03

KITCHENG-08 LOUNGE

G-07

OFFICEG-06

CAPTAIN'S

OFFICEG-05

LIEUTENANT'S

ROOMG-23

CONTROLRECEPTION

G-02

ROOMG-14

MECHANICALVESTIBULE

G-19

ROOMG-12

APPARATUS

SPK

SPK

SPK

SPK

SPK

ROOMG-04

PHONE

14-50R14-50R

2D

2D

DW

V

J

J

J

V2D 2D

J2D

S

S

S

S

V

2D J

2D 2D 2D

SCOCO

S V

CO

S

J

UP

SPK

DW FR FRMIC

2D

2D

WS

14-30R

V

V2D 2D

J2D

S

S

S

SV 2D J

2D 2D 2D

SCOCO

S V

CO

2D

SHOWER

DN

W/CM-02

STAIRHALLM-03

RESCUEM-04

WATER

DORMITORYM-01

HOSE TOWERG-20

SPK

SPK

CO

S

UPFE

SHOWER

DN

S

COCO

A. PROVIDE NEW TYPEWRITTEN PANEL DIRECTORIES TO ACCOMMODATE UPDATED CIRCUITING. NEW BREAKERS IN DISTRIBUTION PANELS SHALL BE LABELLED USING LAMACOIDS.

B. WHERE BRANCH CIRCUIT BREAKERS ARE REMOVED, PROVIDE FILLER PLATES FOR BREAKER SPACES.

C. CIRCUIT BREAKERS SHALL MATCH EXISTING. CONFIRM SHORT CIRCUIT RATING AND TYPE ON SITE, PRIOR TO FINALIZING PRICING.

D. UTILIZE SPARE/FREED UP CIRCUITS FROM DEMOLITION AS REQUIRED TO ACCOMMODATE THE ADDITIONAL CIRCUITING REQUIREMENTS IN THE RENOVATION.

E. FOR ALL STRUCTURED WIRING OUTLETS, PROVIDE NUMER OF JACKS AS INDICATED AND THE CORRESPONDING NUMBER OF CABLES IN CONDUIT STUB INTO CEILING SPACE, THEN HOME RUN TO THE DATA RACK. TERMINATE CABLES IN PATCH PANELS AND IN JACKS AT OUTLET LOCATIONS.

GENERAL NOTES

3

7

7

(TYP)8

Pnl DPnl APnl BPnl C

R

Pnl APnl BPnl C Pnl D

1111

2

B-1

B-13

ES-1B-3,5

B-2

B-4 B-6B-7 B-8 B-9

B-10,12

B-14 4R

B-16B-16

STORAGE ROOMG-22

DRYING ROOMG-21

HOSE TOWERG-20

APPARATUS ROOMG-12

VESTIBULEG-19

MECHANICAL ROOMG-14

STATIONARY ROOMG-11

WOMEN'S WASHROOMG-09

CLEANING ROOMG-10

MEN'S WASHROOMG-16

VESTIBULEG-01

CAPTAIN'S OFFICEG-06

LOUNGEG-07

DORMITORYG-18

LIEUTENANT'S OFFICEG-05

KITCHENG-08

LOCKER ROOMG-17

CORRIDORG-13

CORRIDORG-03

CONTROL ROOMG-23

5

B-15

B-15

B-15B-15

B-15

B-15

6

B-17

QPB-16

9

B-16

B-18

B-18

B-18

B-17

10

HOSE TOWERG-20

DORMITORYM-01

W/CM-02

STAIRHALLM-03

WATER RESCUEM-04

x architecture inc.120 Fort Street, Suite 103 Winnipeg, Manitoba R3C 1C7 204 318 2010

Seal

Engineer

Project

Sheet Title

NO. DATE REVISION / ISSUANCE

SheetProject No .

Date

Architect

19089A

BID OPPORTUNITY 280-2020

799 LILAC STREET

20-06-09

MAIN FLOOR - POWER PLAN

WINNIPEG FPS FIRE STATION #13INTERIOR RENOVATIONS

EP2.1

400 - 136 Market AvenueWinnipeg, MB R3B 0P4

T 204 453 1080

1 EXISTING DEVICE LOCATED BELOW DESK.2 RELOCATE EXISTING VOLUME CONTROL FROM DEMOLISHED WALL TO THIS POSITION.3 EXISTING RECEPTACLES AND JUNCTION BOXES AT 16" AFFL IN THIS SPACE TO BE DEMOLISHED.

NEW RECEPTACLES TO BE PROVIDED AT 18" AFFL4 RELOCATE EXISTING CO ALARM FROM DEMOLISHED WALL TO THIS POSITION.5 HOME RUN DATA CABLES TO EXISTING DATA RACK LOCATED IN MECHANICAL ROOM G-14.6 EXISTING DATA CABINET.7 EXISTING WALL TELEPHONE TO BE DEMOLISHED.8 REMOVE AND REINSTALL FLOOR OUTLETS AS REQUIRED TO ACCOMODATE RENOVATION

WORKS.9 PROVIDE NEW QUAD RECEPTACLE LOCATED BELOW DESK.10 PROVIDE WIREMOLD FOR HDMI CABLES FROM TV CABLE BOX TO WALL MOUNTED TV.

COORDINATE LENGTH WITH ARCHITECTURAL ELEVATIONS.

EP2.1 SCALE: 1/8" = 1'-0"1 MAIN FLOOR PLAN - POWER DEMOLITION

EP2.1 SCALE: 1/8" = 1'-0"2 MAIN FLOOR PLAN - POWER & SYSTEMS

EP2.1 SCALE: 1/8" = 1'-0"3 MEZZANINE FLOOR PLAN - POWER DEMOLITION

EP2.1 SCALE: 1/8" = 1'-0"4 MEZZANINE FLOOR PLAN - POWER & SYSTEMS

Certificate of Authorization

Epp Siepman Engineering Inc.

No. 4035

0 20-06-25 Issued for Construction

KEY NOTES

Page 11: 19089A Working 20 06 30...• STANDARD GYPSUM BOARD TO ASTM C1396/C1396M, REGULAR, 5/8” THICK X 4’-0” WIDTHS, ENDS SQUARE CUT, EDGES TAPERED. APPLICATION AND FINISHING OF GYPSUM

LIGHTING FIXTURE SCHEDULE

A. EMERGENCY LIGHTING MODEL NUMBERS ARE BASED ON LUMACELL PRODUCT LINE. EMERGILITE, BEGHELLI, AND AIMLITE MEETING PERFORMANCE SPECIFICATIONS ARE APPROVED SUBSTITUTIONS.B. WHERE "APPROVED EQUAL" IS LISTED IN THE MANUFACTURER COLUMN, FIXTURES MUST BE SUBMITTED AS A SUBSTITUTION FOR APPROVAL PRIOR TO BID SUBMISSION.

GENERAL NOTES:

EMERGENCY BATTERY BANK SCHEDULE

A. EMERGENCY LIGHTING MODEL NUMBERS ARE BASED ON LUMACELL PRODUCT LINE. EMERGILITE, BEGHELLIE, AND AIMLITE MEETING PERFORMANCE SPECIFICATIONS ARE APPROVED EQUAL.B. WHERE "APPROVED EQUAL" IS LISTED IN THE MANUFACTURER COLUMN, FIXTURES MUST BE SUBMITTED AS A SUBSTITUTION FOR APPROVAL PRIOR TO BID SUBMISSION.C. BATTERY BANK SHALL BE C/W CORD AND 5-15P PLUG. PROVIDE 5-15R/5-20R RECEPTACLE TO MATCH CIRCUIT RATING.

GENERAL NOTES:

LIGHTING CONTROL DEVICE SCHEDULE

SCHEDULE NOTES:

1. PROVIDE 24 VDC POWER PACK WITH INPUT TO MATCH LIGHTING FIXTURE VOLTAGE, SWITCHING CONTACT RATED FOR 20A. BALLAST.

x architecture inc.120 Fort Street, Suite 103 Winnipeg, Manitoba R3C 1C7 204 318 2010

Seal

Engineer

Project

Sheet Title

NO. DATE REVISION / ISSUANCE

SheetProject No .

Date

Architect

19089A

BID OPPORTUNITY 280-2020

799 LILAC STREET

20-06-09

ELECTRICAL SCHEDULES

WINNIPEG FPS FIRE STATION #13INTERIOR RENOVATIONS

E6.1

TYPE Description LENS-LOUVER MOUNTING LAMPBALLAST /

DRIVER VOLT WATTMFR

CATALOG SERIESELA26 DOUBLE HEAD EMERGENCY LIGHTING

DECORATIVE REMOTE. DIE CASTALUMINUM CONSTRUCTION. WHITE

--- WALL 2 x 6W LED50000HR

540 LUMENS

--- 12 V 12 W LUMACELL DR

RD1 114mm (6") DIAMETER DIMMABLE LEDDOWNLIGHT WITH REMOTE PHOSHORLENS ASSEMBLY, 50° CUTOFF.

PHOSPHORLENS

ASSEMBLY ANDCOMFORT

CLEAR DIFFUSEREFLECTOR

RECESSED LED 2000lm3500K

60000 HR

0-10VDIMMING

LED DRIVER

120 V 24 W LIGHTOLIER LDN6

SL1 305mm x 1220mm (1 Foot X 4 Foot) LED K12 ACRYLIC1/8in THICK

SURFACEMOUNTEDON GWB

LED4000lm80+CRI3500K

60000HR

0-10VDIMMING

LED DRIVER

120 V 40 W LITHONIA BTL

UC01 UNDERCABINET TAPE LIGHT MOUNTED INALUMINUM EXTRUSION

FROSTED SURFACE LED 0-10VDC10%

DIMMABLELED DRIVER

120 V MAGICLITE LP-5060

W2 LINEAR WALL MOUNTED VANITY FROSTED SURFACEWALL

LED 1500lm3500K

60000 HR

0-10VDIMMING

LED DRIVER

120 V 56 W FINELITE HP-2

ID DESCRIPTIONBATTERY

SIZE HEADSNUMBER

OF HEADSWATTS

PER HEAD VSRAC

VOLTDC

VOLTSUPPLIED

FROMTOTAL

DC LOADTOTAL DC LOAD WITH

SAFETY FACTORMAX WATT

30 MIN MFR MODELBU1 BATTERY BANK, STEEL CABINET COMPLETE

WITH AC/DC TERMINAL BLOCKS.360 W YES 2 6 YES 120 V 12 V B 157 W 197 W 360 W LUMACELL RG12S360

400 - 136 Market AvenueWinnipeg, MB R3B 0P4

T 204 453 1080

NOTES: EXISTING 120/240V 1PH 3W 42CCT PANEL.

EST. DEMAND CURRENT: 10 ACONNECTED CURRENT: 10 A

ESTIMATED DEMAND: 2427 VACONNECTED LOAD: 2427 VA

LITES 2427 VA 100.00% 2427 VALOAD CLASSIFICATION CONNECTED DEMAND ESTIMATED PANEL TOTALS

TOTAL AMPS: 7 A 15 ATOTAL LOAD: 1 kVA 2 kVA

A-41 A-42A-39 A-40A-37 A-38A-35 A-36A-33 A-34A-31 A-32A-29 A-30A-27 A-28A-25 A-26A-23 A-24A-21 A-22A-19 A-20A-17 A-18A-15 A-16A-13 A-14A-11 A-12A-9 A-10

LITES DORMITORY G-18 15 A 1 A-7 0.4 0.3 A-8 1 15 A LITESLITES CORRIDOR G-13 15 A 1 A-5 0.2 0.3 A-6 1 15 A LITES LOCKER ROOM G-17LITES KITCHEN G-08 15 A 1 A-3 0.6 0.4 A-4 1 15 A LITES LIEUTENANT'S OFFICE G-05LITES CONTROL ROOM G-23 15 A 1 A-1 0.2 0.2 A-2 1 15 A LITES CORRIDOR G-03

LOAD DESCRIPTION BKR P CCT# A B CCT# P BKR LOAD DESCRIPTION

BUS AMPS: 200 AMPSMAIN DEVICE: 150 A MAIN CB SPECIAL:

MOUNTING: SURFACE NEMA 1 A.I.C. RATING: 10,000 AMPS SYMMETRICALLOCATION: MECHANICAL ROOM G-14 VOLTAGE: 120/240 Single V. 1 ...

PANELBOARD: A

NOTES: EXISTING 120/240V 1PH 3W 42CCT PANEL.

EST. DEMAND CURRENT: 17 ACONNECTED CURRENT: 65 A

SPEC 0 VA 0.00% 0 VA ESTIMATED DEMAND: 4132 VALITES 145 VA 100.00% 145 VA CONNECTED LOAD: 15499 VARCPT 15360 VA 26.00% 3994 VALOAD CLASSIFICATION CONNECTED DEMAND ESTIMATED PANEL TOTALS

TOTAL AMPS: 69 A 60 ATOTAL LOAD: 8 kVA 7 kVA

B-41 B-42B-39 B-40B-37 B-38B-35 B-36B-33 B-34B-31 B-32B-29 B-30B-27 B-28B-25 B-26B-23 B-24B-21 B-22B-19 B-20

RCPT DORMITORY G-18 15 A 1 B-17 0.2 0.4 B-18 1 15 A RCPT KITCHEN G-08RCPT DORMITORY G-18 15 A 1 B-15 0.7 0.5 B-16 1 15 A RCPT CONTROL ROOM G-23RCPT KITCHEN G-08 20 A 1 B-13 0.6 1.2 B-14 1 15 A RCPT CLEANING ROOM G-10BU1 15 A 1 B-11 0.1 2.9 B-12RCPT KITCHEN G-08 15 A 1 B-9 1.2 2.9 B-10

2 30 A DRYER RECEPTACLE

RCPT KITCHEN G-08 15 A 1 B-7 1.2 1.2 B-8 1 15 A RCPT KITCHEN G-08B-5 0.0 0.6 B-6 1 20 A RCPT KITCHEN G-08

ELECTRIC STOVE ES-1 90 A 2B-3 0.0 0.6 B-4 1 20 A RCPT KITCHEN G-08

RCPT KITCHEN G-08 15 A 1 B-1 1.2 0.0 B-2 1 15 A SPEC MEN'S WASHROOM G-16LOAD DESCRIPTION BKR P CCT# A B CCT# P BKR LOAD DESCRIPTION

BUS AMPS: 200 AMPSMAIN DEVICE: 200 A MAIN CB SPECIAL:

MOUNTING: SURFACE NEMA 1 A.I.C. RATING: 10,000 AMPS SYMMETRICALLOCATION: MECHANICAL ROOM G-14 VOLTAGE: 120/240 Single V. 1 ...

PANELBOARD: B

TYPE DESCRIPTIONMANUFACTURE

R CATALOG No. WATTS VOLTS NOTESDT3 DUAL TECHNOLOGY PASSIVE INFRARED AND

ULTRASONIC OCCUPANCY SENSOR, 360°COVERAGE, MINIMUM 1000 SQUARE FEET.

nLIGHT NCM PDT 10RJB

0 W 0 V 1

OS COMBINATION ULTRASONIC OCCUPANCYSENSOR/SWITCH, WALL MOUNTED, LOWVOLTAGE, WITH ON-OFF PUSHBUTTON ANDDIMMING.

nLIGHT nWSX PDTLV DX WH

0 W 0 V 1

Certificate of Authorization

Epp Siepman Engineering Inc.

No. 4035

0 20-06-25 Issued for Construction