6

2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively
Page 2: 2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively

2 MPa (20 bar)MRH

Port sizes: 1/2” ÷ 3” 1/2Flow rates: 3 ÷ 1.200 l/min

TECHNICAL DATAMax. working pressure: 2 MPa (20 bar)Max. test pressure: 3 MPa (30 bar)Bursting pressure: 6 MPa (60 bar)Fatigue test: 0 ÷ 1,5 MPa (15 bar) / 1.000.000 cyclesBypass valve: ∆p 300 kPa (3 bar) ± 10%

Filter element collapse pressure:standard: ∆p 1 MPa (10 bar)

Working temperature: -25 ÷ +110°C

MATERIALSHead: anodized aluminiumBowl: anodized aluminium (steel for size 250 only)Seals: standard NBR on request FKM COMPATIBILITY (ISO 2943:1999)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales Department.

All tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test. For further information contact our Technical Dept.

Ret

urn

Filte

rsM

RH

Page 3: 2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively

MRH Type Type

008 015CRH

025 070 150 250

FTFCFDFVCDCVMSMN

FT = 5µm(c)

FC = 7µm(c)

FD = 12µm(c)

FV = 21µm(c)

CD = 10µCV = 25µMS = 60µMN = 90µ

FT = 5µm(c)

FC = 7µm(c)

FD = 12µm(c)

FV = 21µm(c)

CD = 10µCV = 25µMS = 60µMN = 90µ

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

12

1 = NBR Nitrile2 = FKM Fluoroelastomer

1 = NBR Nitrile2 = FKM Fluoroelastomer

12

12

12

12

12

Bypass type

SD

SD

SD

SD

SD

SD

S = WhitoutD = 300 kPa (3 bar)

Ports

B = BSPN = NPTS = SAEF = SAE flange 3000 psi

BNS-

BNS-

BNSF

BNSF

BNSF

---F

Port size

3-----

3 = 1/2” 4 = 3/4”5 = 1”7 = 1” 1/29 = 2” 1/2B = 3” 1/2

-4----

--5---

---7--

----9-

-----B

Accessories

XXXX = No accessory available

XX

XX XX XX XX XX

Indicators

035C6C7CT1

03 = Port, plugged5C = Visual differential 200 kPa (2 bar) 6C = Electrical differential 200 kPa (2 bar)7C = 6C with LEDT1 = Electrical 200 kPa (2 bar) with thermostat 30°C

035C6C7CT1

035C6C7CT1

035C6C7CT1

035C6C7CT1

035C6C7CT1

Inorganic fiber ß>1000

Paper

Inorganic fiber ß>1000

Paper

Steel wire mesh

Filter media Filter media

Seals Seals

Indicator 71 on request only

When the filter is ordered with FKM seals, the first digit of the indicator codeis a letter (please see page 188-189).

Steel wire mesh

HOW TO ORDER THE COMPLETE FILTER HOW TO ORDER THE FILTER ELEMENT

Ret

urn

Filte

rsM

RH

Page 4: 2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively

D5

D4

D2

90°

H1

6

30RD

1H

4

D6

H6

H5

H3

H2

D 3

E3

E2

E1

D5

D4

D2

90°

H1

6

30RD

1H

4

D6

H6

H5

H3

H2

D 3

E3

E2

E1

Indicator port

Type 250: port not available

Type D1 H1D2 H2D3 H3E1 E2 E3D4 H4D5 D6 H5 H6 R Weight Kg

MRH 008...BMRH 008...NMRH 008...SMRH 015...BMRH 015...NMRH 015...SMRH 025...BMRH 025...NMRH 025...SMRH 025...FMRH 070...BMRH 070...NMRH 070...SMRH 070...FMRH 150...BMRH 150...NMRH 150...SMRH 150...FMRH 250...F

83,5 90 5,5 62,5 31,5 3 105= ==

121 128 6,5 3 110= ==

135 147 6,5 4 15552,4 26,2M10

162 174 8,5 4 24070 35,7M12

M12

M16

237 254 10,5 117,5

105

140

177

218 8 27588,9 50,8

95

138

154

180

275

275 237 300 14,5

43

57

67

82

178

160

191

250

323

420

673 =

96

100

97

155

192

248

52

63

82

91

130

4

6

8

8

10

10 5 525

1,3

2,6

3,7

6,5

14,2

49,0120,7 69,9

1/2” BSP1/2” NPT

SAE 8-3/4”-16UNF3/4” BSP3/4” NPT

SAE 12-1 1/16”-12UN1” BSP1” NPT

SAE 16-1 5/16”-12UN1” SAE 30001” 1/2 BSP1” 1/2 NPT

SAE 24-1 7/8”-12UN1” 1/2 SAE 3000

2” 1/2 BSP2” 1/2 NPT

SAE 32-2 1/2”-12UN2” 1/2 SAE 30003” 1/2 SAE 3000

DIMENSIONAL LAYOUT(mm)

Ret

urn

Filte

rsM

RH

Page 5: 2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively

CLOGGING INDICATORS

64,5

30

4835

M20 x 1,5

G R231+

4-

N.C.N.O.C

Setting 200 kPa (2 bar)

NBR FKM

7C EC

Differential ELECTRICAL indicator with LED (24V) for visual indicator

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

23

1

64,5

30

4835

M20 x 1,5

Setting 200 kPa (2 bar)

NBR FKM

6C CC

Differential ELECTRICAL indicator

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

35,5

30

ø 30

M20 x 1,5

Setting 200 kPa (2 bar)

NBR FKM

5C AC

Differential VISUAL indicator

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

70

48

30

M20 x 1,5

Setting 200 kPa (2 bar)

NBR FKM

71 E1

Differential VISUAL ELECTRICAL indicator

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

70

59

32

M20 x 1,5

Setting 200 kPa (2 bar)

NBR FKM

T1 DC

Differential ELECTRICAL indicator with THERMOSTAT 30°C

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

Ret

urn

Filte

rsM

RH

Page 6: 2 MPa (20 bar) · 2018. 7. 10. · NBR FKM 71 E1 Differential VISUAL ELECTRICAL indicator SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively