PROJECT: PROPOSED BRICK VENEER DWELLING CLIENT: ADDRESS: DAHUA GROUP AUSTRALIA Lot No.427 Arthur Allen Drive Bardia Custom Design JOB No: BAR427 FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln LUXURY ESSENTIALS Page 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Drawing PROPOSED SITE PLAN BENCHING PLAN SITE ANALYSIS PLAN STORMWATER CONCEPT PLAN SHADOW DIAGRAMS DA SCHEDULES - PER UNIT GROUND FLOOR PLAN FIRST FLOOR PLAN ELEVATIONS ELEVATIONS GARAGE FLOOR PLAN GARAGE ELEVATIONS SECTIONS DETAILS DOOR & WINDOW SCHEDULE - 6.5m LH DOOR & WINDOW SCHEDULE - 6.5m RH - Reduced DOOR & WINDOW SCHEDULE - Type A DOOR & WINDOW SCHEDULE - Type B COLOUR SELECTION PAGE A L L E N D R I V E ROAD ROAD L A N E ( 7 W I D E) 339 340 341 360 361 362 363 364 365 379 380 427 AD J O I N S A R T H U R M . G.A. LOCATION PLAN

2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

  • Upload
    others

  • View
    13

  • Download
    3

Embed Size (px)

Citation preview

Page 1: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

PROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DAHUA GROUP AUSTRALIA

Lot No.427 Arthur Allen Drive

Bardia

Custo

m D

esig

n

JOB No:

BAR427

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

L U X U R Y E S S E N T I A L S

Page

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Drawing

PROPOSED SITE PLAN

BENCHING PLAN

SITE ANALYSIS PLAN

STORMWATER CONCEPT PLAN

SHADOW DIAGRAMS

DA SCHEDULES - PER UNIT

GROUND FLOOR PLAN

FIRST FLOOR PLAN

ELEVATIONS

ELEVATIONS

GARAGE FLOOR PLAN

GARAGE ELEVATIONS

SECTIONS

DETAILS

DOOR & WINDOW SCHEDULE - 6.5m LH

DOOR & WINDOW SCHEDULE - 6.5m RH - Reduced

DOOR & WINDOW SCHEDULE - Type A

DOOR & WINDOW SCHEDULE - Type B

COLOUR SELECTION PAGE

ALLEN

DRIVE

ROAD

ROAD

LANE

(7 WIDE)

339

340

341

360

361

362

363

364

365

379

380

427

ADJOINS

ARTHUR

M.G

.A.

LOCATION PLAN

Page 2: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

2

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

Up

1

2

Up

1

2

3

Up

1

2

3

Up

1

2

3

Up

1

2

3

4

Up

1

2

3

4

N

4,2

82

4,6

30

4,9

76

1,185

500

500

500

1,185 1,285

50

0

1,285 1,2851,285 1,185

1,185

925 925

3,0

00

1,8

00

1,035

1,035

4,0

27

1.73 m21.67 m21.37 m2

1.37 m2 1.67 m2

1.73 m2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

APPROX. LOCATION OFEXISTING SEWER MAIN

PROPOSED LANE

363

364

30.925

31.5

10

'A'

'B'

'B'

T.M.S.

276º 49' 20"

94º 36'

15"

49

'

20

"

18

49

'

20

"

LOT 427Area: 955.20m2

ARTHUR ALLEN DRIVE

361

362

30.900

30.3

15

TY

PIC

AL

FR

ON

TS

ET

BA

CK

TY

PIC

AL

PO

RC

HS

ET

BA

CK

'A' - EASEMENT TO DRAIN WATER 1.5 WIDE'B' - EASEMENT FOR ACCESS AND MAINTENANCE 0.9 WIDE

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

UNIT 1 UNIT 2 UNIT 3UNIT 4 UNIT 5 UNIT 6

STORMWATER DRAINAGE TOSTREET WATER TABLE.(SUBJECT TO CONTOUR SURVEY)

PROPOSEDEXCAVATION

Lot No.427AREA: 955.20m2

EXCAVATE SITE APPROX. xxx mm TOFORM JOB DATUM R.L 00.000(ASSUMED) DATUM POINT 385mmBELOW FINISHED FLOOR LEVEL.EXTENT OF EXCAVATION AND BATTERSTO BE DETERMINED ON SITE.

'H1' CLASS SITE ASSUMED(SUBJECT TO BOREHOLE REPORT)

ANY RETAINING WALLS REQUIRED TO BECOMPLETED BY OWNERS TOMANUFACTURERS SPECIFICATIONS.

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

427 / DRAFT

R2 31.000m

955.20 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

402.28 m²

340.90 m²

26.94 m²

0.00 m²

24.08 m²

0.00 m²

123.62 m²

87.42 m²

1,005.24 m²

19.26 m²

597.45 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%525.90 m²/ 55.06%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

525.36 m²/ 55.00%765.06 m²/ 80.09%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

191.04 m²/ 20.00%293.68 m²/ 30.75%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.0226.18 m²/ 9.25x4.0

THIS SITE PLAN HAS BEEN PREPARED WITH ADRAFT LINEN PLAN IT SHOULD NOT BE USED FORCALCULATION OR SETOUT PURPOSES. ALLDIMENSIONS AND AREAS ARE SUBJECT TO FINALREGISTRATION.

NOTE:ALL BOUNDARY LENGTHS, BEARINGS, SETBACKS,

LOCATION OF SEWER/EASEMENT, LEVELS &

CUT/FILL ALL APPROXIMATE/ASSUMED AND ARE

SUBJECT TO CONTOUR SURVEY/REGISTRATION.

LOCATION OF SEWER TO BE CONFIRMED ONCE

THE LAND IS REGISTERED AND A CERTIFIEDSURVEY HAS BEEN RECIEVED.

ASSUMED EASEMENT FOR SUPPORTMAINTENANCE & REPAIR 0.9 WIDE SUBJECT TOCONTOUR SURVEY/REGISTRATION.

SEWER MAIN

RECYCLED WATER MAIN

WATER MAIN

STORMWATER DRAIN WATER PIT

PROPOSED BOUNDARY LINE

SITE PLAN 1:200

Page 3: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

3

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

STOCKPILESTOCKPILE

N

(BENCHING RL:63.845) (BENCHING RL:63.505)

(BENCHING RL:62.750)RL:63.260(BENCHING RL:62.960)

(BENCHING RL:63.250)

RL: 64.230 RL: 63.890

(BENCHING RL:63.530)

RL:63.550RL:63.830

RL:63.050

RL:64.145 RL:63.805

APPROX. LOCATION OFSEDIMENT CONTROL FENCEAS PER COUNCILREQUIREMENTS.

PROVIDE TEMPORARYSECURITY FENCING TO SITE

TEMPORARILY STABILISEVEHICLE ACCESS DRIVEWAY(GRAVEL/ROCK AGGREGATE)

TEMPORARILY STABILISEVEHICLE ACCESS DRIVEWAY(GRAVEL/ROCK AGGREGATE)

PROPOSED LANE

363

364

30.925

31.5

10

'A'

'B'

'B'

T.M.S.

276º 49' 20"

94º 36'

15"

49

'

20

"

18

49

'

20

"

DEBDEBDEB DEB DEB DEB

DEB

DEB

DEB DEB DEB

LOT 427Area: 955.20m2

ARTHUR ALLEN DRIVE

361

362

30.900

30.3

15

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

UNIT 1 UNIT 2 UNIT 3UNIT 4 UNIT 5 UNIT 6

'A' - EASEMENT TO DRAIN WATER 1.5 WIDE'B' - EASEMENT FOR ACCESS AND MAINTENANCE 0.9 WIDE

340STEPDOWN

85

ST

EP

DO

WN

85S

TE

PD

OW

N

85

ST

EP

DO

WN

85

ST

EP

DO

WN

85

ST

EP

DO

WN

85S

TE

PD

OW

N

85

ST

EP

DO

WN

85S

TE

PD

OW

N

R.L 63.02F485

R.L 63.80C295

R.L 63.78F65

R.L 64.13C285

R.L 63.00C40

R.L 62.81F150

R.L 63.14C180

R.L 62.98C20

R.L 63.22F30

R.L 63.05F200

R.L 63.49C240

R.L 63.25F0

R.L 63.70C170

R.L 63.59C60

R.L 63.61C80

R.L 63.36F170

R.L 62.94C190

R.L 62.75F0

R.L 62.85C100

R.L 62.65F100

R.L 63.380F465

R.L 63.98C135

R.L 63.98C475

R.L 63.38F125

STORMWATER DRAINAGE TOSTREET WATER TABLE.(SUBJECT TO CONTOUR SURVEY)

PROPOSEDEXCAVATION

Lot No.427AREA: 955.20m2

EXCAVATE SITE APPROX. xxx mm TOFORM JOB DATUM R.L 00.000(ASSUMED) DATUM POINT 385mmBELOW FINISHED FLOOR LEVEL.EXTENT OF EXCAVATION AND BATTERSTO BE DETERMINED ON SITE.

'H1' CLASS SITE ASSUMED(SUBJECT TO BOREHOLE REPORT)

ANY RETAINING WALLS REQUIRED TO BECOMPLETED BY OWNERS TOMANUFACTURERS SPECIFICATIONS.

SEDIMENT CONTROL DETAIL

STAR PICKET 1.35m LONG900mm MAX. ABOVE GROUND

APPROX 450mmBELOW GROUND

POST SHOULD NOTBE SPACED MORETHAN 3.0m APART

3.5mm STEEL WIRERINGCLIP TO FABRIC

DRAPE 150mm OF SILTSTOP (BELOW RED GAUGELINE) BACKFILL WITH SOILAND COMPACT.

PROPEX SILTSTOPSEDIMENTCONTROL FABRIC

200mm TRENCHALONG FENCE

BASIX NOTES

WATER

- RAINWATER TANK OF AT LEAST 3,000 LITRES TO BE INSTALLED.- RAINWATER TANK MUST MEET AND BE INSTALLED INACCORDANCE WITH APPLICABLE REGULATORY AUTHORITIES.- RAINWATER TANK TO COLLECT RAIN RUNOFF FROM AT LEAST150.00m2 OF ROOF AREA.- RAINWATER TANK SUPPLY TO BE CONNECT TO ALL TOILETS INTHE DEVELOPMENT.- KITCHEN TAP FITTING RATING 4 STAR- SHOWERHEAD RATING 3 STAR- TOILET RATING (DUAL FLUSH) 4 STAR- BATHROOM TAP FITTING RATING 6 STAR- RAINWATER TANK TO BE CONNECTED TO AT LEAST ONEOUTDOOR TAP IN THE DEVELOPMENT.

THERMAL COMFORT

EXTERNAL WALLS: BRICK VEENER/TIMBER FRAMEEXTERNAL WALL INSULATION: R2.0EXTERNAL WALL COLOUR: MEDIUMROOFING MATERIAL: CONCRETE ROOF TILESROOF INSULATION: SARKINGROOF COLOUR: MEDIUMCEILING INSULATION: R3.5

ENERGY

- ACTIVE HEATING AND COOLING TO BE INSTALLED IN LIVING ANDBEDROOMS, 3 PHASE A/C SYSTEM (EER 2.5-3.0). TO BE DAY/NIGHTZONED BETWEEN LIVING AREAS AND BEDROOMS. TO BEINSTALLED PRIOR TO FINAL OCCUPATION CERTIFICATE.- PROVIDE GAS 6 STAR INSTANTANEOUS HWS.- PROVIDE GAS COOKTOP TO KITCHEN.- PROVIDE ELECTRIC OVEN TO KITCHEN.- ALL REFRIGERATOR SPACES TO BE WELL VENTILATED.- PROVIDE COMPACT FLUORESCENT ENERGY SAVING LIGHT BULBSTO ALL LIGHT POINTS.- PROVIDE OUTDOOR CLOTHES LINE BY OWNER.

BENCHING PLAN 1:200

Page 4: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

4

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

AF

TE

RN

OO

N

(WE

ST

)

MIDDAY

(NORTH)

MO

RN

ING

(EA

ST

)

SO

UTH-W

EST

WIN

TER

WIN

DS

NO

RTH

-EAST

SUM

MER W

IND

S

N

P

PROPOSED LANE

363

364

30.925

31.5

10

'A'

'B'

'B'

T.M.S.

276º 49' 20"

94º 36'

15"

49

'

20

"

18

49

'

20

"

P P P P P

LOT 427Area: 955.20m2

ARTHUR ALLEN DRIVE

361

362

30.900

30.3

15

'A' - EASEMENT TO DRAIN WATER 1.5 WIDE'B' - EASEMENT FOR ACCESS AND MAINTENANCE 0.9 WIDE

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

UNIT 1 UNIT 2 UNIT 3UNIT 4 UNIT 5 UNIT 6

(1)

(2)

SINGLE STOREY

TWO STOREY

OVERLOOKING

PREVAILING WINDS

PRIVATE OPEN SPACE

SUNLIGHT/SHADOWING

SITE ANAYLSIS KEY

P

Page 5: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

5

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

D.P

D.P

D.P D.P

D.PD.P

D.P D.P D.P D.P D.P D.PD.P D.P

D.P

D.P

D.P

D.P

D.PD.P

Up

1

2

Up

1

2

3

Up

1

2

3

Up

1

2

3

Up

1

2

3

4

Up

1

2

3

4

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

N

1.73 m21.67 m21.37 m2

1.37 m2 1.67 m2

1.73 m2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

1.6

2 m

2

APPROX. LOCATION OFEXISTING SEWER MAIN

PROPOSED LANE

363

364

30.925

31.5

10

'A'

'B'

'B'

T.M.S.

276º 49' 20"

94º 36' 15"

49

'

20

"

18

49

'

20

"

PIT PIT PIT

PIT

PIT PIT

INDIVIDUAL STORMWATER LINES TO

PASS BENEATH SLAB OF UNITS 2 - 5

PIT PIT PITPIT PIT PIT

LOT 427Area: 955.20m2

ARTHUR ALLEN DRIVE

361

362

30.900

30.3

15

'A' - EASEMENT TO DRAIN WATER 1.5 WIDE'B' - EASEMENT FOR ACCESS AND MAINTENANCE 0.9 WIDE

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

UNIT 1 UNIT 2 UNIT 3UNIT 4 UNIT 5 UNIT 6

The stormwater design/layout which flows to thestreet/easement is in compliance with:

1. Building Code of Australia Vol. 2 (BCA)Sections 3.1 Site Preparation, and 3.5 Roof andWall Cladding

2. Council stormwater DCP requirements (if

applicable).

3. Using data from BCA Tables 3.5.2.1 and3.5.2.2 the number of downpipes required basedon a roof area of 270m2 is 7.

Name

Signed Date

STORMWATER LINES

STORMWATER CONCEPT PLAN 1:200

Page 6: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

6

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

SHADOW PROJECTIONS 21st JUNE

9AM 12PM 3PM

Page 7: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

7

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

432 / DRAFT

R2 6.450m

196.29 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

76.48 m²

62.45 m²

5.79 m²

0.00 m²

4.36 m²

0.00 m²

24.07 m²

15.35 m²

188.50 m²

3.35 m²

116.42 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%100.55 m²/ 51.23%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

107.96 m²/ 55.00%122.66 m²/ 62.49%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

39.26 m²/ 20.00%71.25 m²/ 36.30%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.043.15 m²/ 9.25x4.0

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

432 / DRAFT

R2 4.500m

137.90 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

62.33 m²

54.00 m²

4.07 m²

0.00 m²

4.07 m²

0.00 m²

18.87 m²

14.18 m²

157.52 m²

2.99 m²

91.39 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%81.20 m²/ 58.88%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

75.85 m²/ 55.00%103.01 m²/ 74.70%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

27.58 m²/ 20.00%35.24 m²/ 25.55%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.032.66 m²/ 9.25x4.0

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

432 / DRAFT

R2 4.500m

138.69 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

62.33 m²

54.00 m²

4.07 m²

0.00 m²

4.07 m²

0.00 m²

18.87 m²

14.18 m²

157.52 m²

3.29 m²

91.39 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%81.20 m²/ 58.55%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

76.28 m²/ 55.00%103.01 m²/ 74.27%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

27.74 m²/ 20.00%35.72 m²/ 25.76%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.032.66 m²/ 9.25x4.0

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

432 / DRAFT

R2 4.500m

139.48 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

62.33 m²

54.00 m²

4.07 m²

0.00 m²

4.07 m²

0.00 m²

18.87 m²

14.18 m²

157.52 m²

2.99 m²

2.45 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%81.20 m²/ 58.22%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

76.71 m²/ 55.00%103.01 m²/ 73.85%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

27.90 m²/ 20.00%36.81 m²/ 26.39%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.034.22 m²/ 9.25x4.0

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

432 / DRAFT

R2 4.500m

140.26 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

62.33 m²

54.00 m²

4.07 m²

0.00 m²

4.07 m²

0.00 m²

18.87 m²

14.18 m²

157.52 m²

3.29 m²

91.39 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%81.20 m²/ 57.89%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

77.14 m²/ 55.00%103.01 m²/ 73.44%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

28.05 m²/ 20.00%37.29 m²/ 26.59%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.034.22 m²/ 9.25x4.0

DA SCHEDULE

SITE DETAILS

LGA CONTROL

LOT NUMBER/DP NUMBER

ZONE & LOT WIDTH

SITE AREA

Campbelltown DCP 2015

432 / DRAFT

R2 6.450m

202.41 m²

DWELLING AREAS

GROUND FLOOR LIVING

FIRST FLOOR LIVING

PORCH

PATIO

FRONT BALCONY

REAR BALCONY

GARAGE

OUTDOOR LEISURE

TOTAL :

DRIVE AREA

ROOF AREA (drained to tank)

76.48 m²

62.45 m²

4.87 m²

0.00 m²

3.44 m²

0.00 m²

24.07 m²

15.35 m²

186.66 m²

3.35 m²

92.67 m²

SITE COVERAGE (Single storey/Lower floor)

MAXIMUM SITE COVERAGEACTUAL SITE COVERAGE

0.00 m²/ 0.00%100.55 m²/ 49.68%

FLOOR SPACE RATIO

MAXIMUM FLOOR SPACE/FSRACTUAL FLOOR SPACE/FSR

111.33 m²/ 55.00%122.66 m²/ 60.60%

LANDSCAPING AREAS

MINIMUM LANDSCAPINGACTUAL LANDSCAPING

40.48 m²/ 20.00%78.28 m²/ 38.67%

PRIVATE OPEN SPACE

MINIMUM POSACTUAL POS

75.00 m²/ 5.0x5.049.27 m²/ 9.25x4.0

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

DA Schedules - Individual Lots

Page 8: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

8

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

720720920AS1812T AS1808T

820

SXD 2136

720720920AS1812T AS1808T

820

SXD 2136

720720920AS1812T AS1808T

820

SXD 2136

720720920AS1812T AS1808T

820

SXD 2136

720920

AS1812TAS1808T

AS

0906

AS

0918

AS

1824

TA

F06

16

SD 2124

820720 820 720920

AS1808T AS1812T

AS

0906

AS

0918

AS

1824

TA

F06

16

SD 2124

820 720820ohcref P.

ohc ohc

W.M.

4.25 x 3.15

4.24 x 4.19

4.24 x 2.51

3.00 x 3.56

1.78 x 0.901.18 x 0.90

3.40 x 1.20

BEAM OVER

BEAM OVER

EL

EC

ME

TE

R

ohcref P.

ohc ohc

W.M.

4.25 x 3.15

4.25 x 4.19

4.25 x 2.51

3.00 x 3.56

1.78 x 0.901.18 x 0.90

3.40 x 1.20

BEAM OVER

BEAM OVER

EL

EC

ME

TE

R

ohcref P.

ohc ohc

W.M.

4.25 x 3.15

4.25 x 4.19

4.25 x 2.51

3.00 x 3.56

1.78 x 0.901.18 x 0.90

3.40 x 1.20

BEAM OVER

BEAM OVER

EL

EC

ME

TE

R

ohcref P.

ohc ohc

W.M.

4.25 x 3.15

4.24 x 4.19

4.24 x 2.51

3.00 x 3.56

1.78 x 0.901.18 x 0.90

3.40 x 1.20

BEAM OVER

BEAM OVER

EL

EC

ME

TE

R

W.M.

ohc

ref

1370x900

P.

ohc

ohcohc

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

BEAM OVER

BEAM OVER

BE

AM

OV

ER

BEAM OVER

2.86 x 3.00

2.21 x 1.57

1.51 x 1.66

1.77 x 2.75

5.16 x 3.38

2.81 x 3.52

2.35 x 4.03

5.40 x 3.00

3.63 x 2.16

W.M.

ohc

ref

1370x900

P.

ohc

ohc ohc

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

BEAM OVER

BEAM OVER

BE

AM

OV

ER

BEAM OVER

2.86 x 3.00

2.21 x 1.57

1.51 x 1.66

1.77 x 2.75

5.16 x 3.38

2.81 x 3.52

2.35 x 4.03

5.40 x 3.00

2.87 x 2.16

ROBE ROBE

29,050

29,050

2,740 2,660 250 4,250 250 4,250 250 4,250 250 4,250 250 2,660 2,740

18,2

00

1,2

00

14

,60

02,4

00

18,2

00

1,2

00

14

,60

02,4

00

3,340 2,185 18,000 2,185 3,340

1,200 3,630 695 3,395 1,105 3,395 1,105 3,395 1,105 3,395 1,800 2,870 1,960

STACKPOINT

550 x 1180SKYLIGHTSTYPICAL

550 x 1180SKYLIGHTSTYPICAL

550 x 1180SKYLIGHTSTYPICAL

STACKPOINT

550 x 1180SKYLIGHTSTYPICAL

STACKPOINT

STACKPOINT

470 x 350BRICKCOLUMN

470 x 350BRICKCOLUMN

550 x 1180SKYLIGHTSTYPICAL

350 x 350 BRICK COLUMN

350 x 350BRICKCOLUMN

550 x 1180SKYLIGHTSTYPICAL

350 x 350 BRICK COLUMN

350 x 350BRICK

COLUMN

470 x 350BRICKCOLUMN

470 x 350BRICKCOLUMN

KITCHEN

PORCH

1 2 3 4 5 6 7 8 9 10

11

12

13

1415

ct ubo

rh

Up

FAMILY

LIVING/MEALS

ALFRESCO

L'DRY

skylightskylight

skylightskylight

HARDIES

ZERO LOT

60/60/60 FRL

W.C.

1 2 3 4 5 6 7 8 9 10

11

12

131415

ct ubo

rh

Up

skylightskylight

skylightskylight

KITCHEN

PORCH

FAMILY

LIVING/MEALS

ALFRESCO

L'DRY

HARDIES

ZERO LOT

60/60/60 FRL

W.C.

1 2 3 4 5 6 7 8 9 10

11

12

131415

ct ubo

rh

Up

skylightskylight

skylightskylight

KITCHEN

PORCH

FAMILY

LIVING/MEALS

ALFRESCO

L'DRY

HARDIES

ZERO LOT

60/60/60 FRL

W.C.

KITCHEN

PORCH

1 2 3 4 5 6 7 8 9 10

11

12

13

1415

ct ubo

rh

Up

FAMILY

LIVING/MEALS

ALFRESCO

L'DRY

skylightskylight

skylightskylight

HARDIES

ZERO LOT

60/60/60 FRL

W.C.

KITCHEN

Up

GUEST

DINING

LIVING

ENTRY

L'DRY

PW'DR

skylightskylight

skylightskylight

STORE

KITCHEN

Up

GUEST

DINING

LIVING

ENTRY

L'DRY

PW'DR

skylight skylight

skylight skylight

STORE

85mm SETDOWNTO PORCH

85mm SETDOWNTO PORCH

85mm SETDOWNTO PORCH

85mm SETDOWNTO PORCH

HARDIES

ZERO LOT

60/60/60 FRL

PORCH

ALFRESCO

85mm SETDOWNTO PORCH

85mm SETDOWNTO ALFRESCO

PORCH

ALFRESCO

85mm SETDOWNTO PORCH

85mm SETDOWNTO ALFRESCO

tub tub tubtubtub tub

NOTES:

- STACK POINT LOCATIONS SUBJECT TO FLOOR JOIST LAYOUT.- STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART3.9.1.3 OF B.C.A 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013.- OPENABLE WINDOWS TO BE IN ACCORANCE WITH CLAUSE 3.9.2.5 OF THE

BCA 2013 VOL. 2

- FIRST FLOOR WINDOWS TO BE RESTRICTED TO OPEN A MAX. OF 125mm IF

SILL HEIGHT IS LOWER THAN 1700mm ABOVE A FLOOR LEVEL.

Areas - 4.5m Type B

AreaLOWER LIVING

ALFRESCO

PORCH

UPPER LIVING

BALCONY

m²62.33

14.18

4.07

54.00

4.07

138.65 m²

Areas - 4.5m Type A

AreaLOWER LIVING

ALFRESCO

PORCH

UPPER LIVING

BALCONY

m²62.33

14.18

4.07

54.00

4.07

138.65 m²

Areas - 6.5m RH - Reduced

AreaBALCONY

UPPER LIVING

PORCH

LOWER LIVING

ALFRESCO

m²3.44

62.45

4.87

76.48

15.35

162.59 m²

Areas - 6.5m LH

AreaBALCONY

UPPER LIVING

PORCH

LOWER LIVING

ALFRESCO

m²4.36

62.45

5.79

76.48

15.35

164.43 m²

Unit 1

Units 2 & 4

Unit 6

Units 3 & 5

UNIT 1 UNIT 6UNIT 5UNIT 4UNIT 3UNIT 2

GROUND FLOOR PLAN 1:100

Page 9: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

9

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

AS1806TSD 2124

AS0624820 720720720 420AS1206

SD 2124

AS0624820 720720720 420AS1206

SD 2124

AS0624820 720720720 420AS1806TSD 2124

AS0624820 720720720 420SD 2124

AS

0612

AS

1216

AS0624AS0606 720720 820720820 820720SD 2122

AS

061

2A

S1

21

6

AS0624 AS0606720720820 720820820 7201

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

vanity1600

1400x900

3.63 x 2.98

3.05 x 2.77

3.53 x 1.20

3.65 x 3.56

vanity1600

1400x900

3.63 x 2.98

3.05 x 2.77

3.53 x 1.35

3.64 x 3.56

vanity1600

1400x900

3.63 x 2.98

3.05 x 2.77

3.53 x 1.35

3.64 x 3.56

vanity1600

1400x900

3.63 x 2.98

3.05 x 2.77

3.53 x 1.20

3.65 x 3.56

900x900

3.51 x 3.00

3.11 x 2.98

3.11 x 2.02

1.80 x 1.40

1.80 x 1.91

3.27 x 3.40

3.63 x 1.20

900x900

3.51 x 3.00

3.11 x 2.98

3.11 x 2.02

1.80 x 1.40

1.80 x 1.91

3.27 x 3.40

2.87 x 1.20

RO

BE

RO

BE

RO

BE

RO

BE

RO

BE

RO

BE

RO

BE

RO

BE

RO

BE

ROBE

RO

BE

ROBE

150 1,050 3,630 695 4,500 4,500 4,500 4,500 695 3,630 1,050 150

29,050

29,050

150 28,750 150

13,2

00

1,2

00

2,6

50

9,3

50

13

,20

0

35

08

50

2,6

50

9,3

50

150 1,050 350 2,930 350 695 350 2,575 470 1,105 350 2,575 470 1,105 350 2,575 470 1,105 350 2,575 470 1,105 695 350 2,170350

760 1,050 150

2 3 4 5 6 7 8 9 10

11

12

13

141516

linen

BED 1

BED 2

BATH

BALCONY

2 3 4 5 6 7 8 9 10

11

12

13141516

linen

BED 1

BED 2

BATH

2 3 4 5 6 7 8 9 10

11

12

13141516

linen

BED 1

BED 2

BATH

2 3 4 5 6 7 8 9 10

11

12

13

141516

linen

BED 1

BED 2

BATH

BALCONY

WIR

BED 1

BED 2

BED 3

BATH

ENS

BALCONY

WIR

BED 1

BED 2

BED 3

BATH

ENS

BALCONYBALCONY BALCONY

NOTES:

- STACK POINT LOCATIONS SUBJECT TO FLOOR JOIST LAYOUT.- STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART3.9.1.3 OF B.C.A 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013.- OPENABLE WINDOWS TO BE IN ACCORANCE WITH CLAUSE 3.9.2.5 OF THE

BCA 2013 VOL. 2

- FIRST FLOOR WINDOWS TO BE RESTRICTED TO OPEN A MAX. OF 125mm IF

SILL HEIGHT IS LOWER THAN 1700mm ABOVE A FLOOR LEVEL.

Areas - 4.5m Type B

AreaLOWER LIVING

ALFRESCO

PORCH

UPPER LIVING

BALCONY

m²62.33

14.18

4.07

54.00

4.07

138.65 m²

Areas - 4.5m Type A

AreaLOWER LIVING

ALFRESCO

PORCH

UPPER LIVING

BALCONY

m²62.33

14.18

4.07

54.00

4.07

138.65 m²

Areas - 6.5m RH - Reduced

AreaBALCONY

UPPER LIVING

PORCH

LOWER LIVING

ALFRESCO

m²3.44

62.45

4.87

76.48

15.35

162.59 m²

Areas - 6.5m LH

AreaBALCONY

UPPER LIVING

PORCH

LOWER LIVING

ALFRESCO

m²4.36

62.45

5.79

76.48

15.35

164.43 m²

UNIT 1UNIT 5UNIT 4UNIT 3UNIT 2

UNIT 6

FIRST FLOOR PLAN 1:100

Unit 1

Units 2 & 4

Unit 6

Units 3 & 5

Page 10: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

10

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

85

2,5

90

32

02,4

40

1,6

85

RL:63.805

RL:63.890

RL:66.480

RL:66.800

RL:69.240

RL:70.925

85

2,5

90

32

02,4

40

1,6

85

RL:64.145

RL:64.230

RL:66.820

RL:67.140

RL:69.580

RL:71.265

34

0UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 685

2,5

90

32

02,4

40

1,6

85

RL:63.805

RL:63.890

RL:66.480

RL:66.800

RL:69.240

RL:70.925

85

2,5

90

32

02

,44

01

,68

5

RL:64.145

RL:64.230

RL:66.820

RL:67.140

RL:69.580

RL:71.265

34

0 UNIT 1UNIT 2UNIT 3UNIT 4UNIT 5UNIT 6

SOUTHERN FRONT/ELEVATION1:100

NORTHERN REAR/ELEVATION1:100

Page 11: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

11

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

38

5

21

51

70

LOOSE FILL/BACKFILL

300mm PODS

TYPICAL NATURALGROUND LINE

BENCHING LINE

RETICULATED TERMITE PIPEAS PER MANUFACTURERS DETAILS

TYPICAL DPC

F.F.L

'H' CLASS BENCHING DETAIL

BENCHING LEVEL

TYPICAL WEEPHOLE POSITION

NOTES:

- STACK POINT LOCATIONS SUBJECT TO FLOOR JOIST LAYOUT.- STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART3.9.1.3 OF B.C.A 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013.- OPENABLE WINDOWS TO BE IN ACCORANCE WITH CLAUSE 3.9.2.5 OF THE

BCA 2013 VOL. 2

- FIRST FLOOR WINDOWS TO BE RESTRICTED TO OPEN A MAX. OF 125mm IF

SILL HEIGHT IS LOWER THAN 1700mm ABOVE A FLOOR LEVEL.

2,5

90

32

02,4

40

1,6

85

34

0

RL:63.890

RL:66.480

RL:66.800

RL:69.240

RL:70.925

RL:71.265UNIT 6

2,5

90

32

02,4

40

1,6

85

RL:64.230

RL:66.820

RL:67.140

RL:69.580

RL:71.265

UNIT 1

EASTERN RIGHT/ELEVATION1:100

WESTERN LEFT/ELEVATION1:100

Page 12: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

12

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

820820 820 820820820 3.90 x 5.50

3.90 x 5.50

3.00 x 5.50 3.00 x 5.50

3.00 x 5.503.00 x 5.50

4,080 2,470 6,430 2,570 6,430 2,470 4,080

4,380 2,170 6,730 2,270 6,730 2,170 4,380

28,830

5,8

20

4,7

50

1,0

70

34

6

4,7

50

1,0

70

34

8

4,7

50

1,0

70

25

5

5,8

20

4,7

50

1,0

70

4,7

50

1,0

70

GARAGE

PANEL LIFT DOOR

GARAGE

PANEL LIFT DOOR

GARAGE

HARDIES

ZERO LOT

60/60/60 FRL

PANEL LIFT DOOR

GARAGE

HARDIES

ZERO LOT

60/60/60 FRL

PANEL LIFT DOOR

GARAGE

HARDIES

ZERO LOT

60/60/60 FRL

PANEL LIFT DOOR

GARAGE

HARDIES

ZERO LOT

60/60/60

FRL

PANEL LIFT DOOR

Garage Areas - 6.5m

AreaGARAGE

m²24.07

24.07 m²

Garage Areas - 4.5m

AreaGARAGE

m²18.87

18.87 m²

Lots 1 & 6 Lots 2 - 5

UNIT 1

UNIT 6UNIT 5UNIT 4

UNIT 3UNIT 2

Page 13: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

13

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

2,5

90

1,1

80

RL:63.830

RL:66.420

RL:67.600

2,5

90

1,1

80

RL:63.050

RL:65.640

RL:66.820

2,5

90

1,1

80

RL:63.260

RL:65.850

RL:67.030

2,5

90

1,1

80

RL:63.550

RL:66.140

RL:67.320

2,1

45

25

C1,6

25

19

C

2,1

45

25

C1

,62

519

C

2,1

45

25C

1,6

25

19C

2,1

45

25

C1,6

25

19

C

UNIT 1UNIT 2UNIT 3UNIT 4UNIT 5UNIT 6

2,5

90

1,1

80

RL:63.830

RL:66.420

RL:67.600UNIT 1

2,5

90

1,1

80

RL:63.050

RL:65.640

RL:66.820

UNIT 6

2,5

90

1,1

80

RL:63.830

RL:66.420

RL:67.600

2,5

90

1,1

80

RL:63.050

RL:65.640

RL:66.820

2,5

90

1,1

80

RL:63.260

RL:65.850

RL:67.030

2,5

90

1,1

80

RL:63.550

RL:66.140

RL:67.320

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

NORTHERN GARAGE FRONT1:100

WESTERN GARAGE RIGHT1:100

EASTERN GARAGE LEFT1:100

SOUTHERN GARAGE REAR1:100

Page 14: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

14

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

2,5

90

32

02,4

40

1,6

85

2,5

90

320

2,4

40

1,6

85

RL:64.230

RL:66.820

RL:67.140

RL:69.580

RL:71.265

RL:63.890

RL:66.480

RL:66.800

RL:69.240

RL:70.925

UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6

NOTES:

- STACK POINT LOCATIONS SUBJECT TO FLOOR JOIST LAYOUT.- STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART3.9.1.3 OF B.C.A 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013.- OPENABLE WINDOWS TO BE IN ACCORANCE WITH CLAUSE 3.9.2.5 OF THE

BCA 2013 VOL. 2

- FIRST FLOOR WINDOWS TO BE RESTRICTED TO OPEN A MAX. OF 125mm IF

SILL HEIGHT IS LOWER THAN 1700mm ABOVE A FLOOR LEVEL.

38

5

21

51

70

LOOSE FILL/BACKFILL

300mm PODS

TYPICAL NATURALGROUND LINE

BENCHING LINE

TYPICAL DPC

F.F.L

'H' CLASS BENCHING DETAIL

BENCHING LEVEL

GRANITGARD TERMITE BARRIERAS PER MANUFACTURERS DETAILS

TYPICAL WEEPHOLE POSITION

GRANITGARDUPVC STRIP SHIELDFLUSH WITH MORTAR

SECTION A-A1:100

Page 15: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

15

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

Page 16: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

16

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

Door Schedule - 6.5m LH

Door

No.

D1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D11

D12

D13

D14

D15

D16

D17

Type

External Hung

Door

Sliding Door

Hung Door

Sliding RobeDoors

Hung Door

Hung Door

Hung Door

Sliding Door

Hung Door

Sliding Robedoors

Hung Door

Hung Door

Hung Door

Hung Door

Hung Door

Hung Door

External HungDoor

Door Size

Height

2,040

2,100

2,040

2,100

2,040

2,040

2,040

2,100

2,040

2,100

2,040

2,040

2,040

2,040

2,040

2,040

2,040

Width

920

2,410

820

1,600

720

820

720

2,410

820

1,500

820

720

720

820

720

720

820

Plan

View

SD 2124

SD 2124

Elev.

ViewGlazing

Glass - SingleClear

Glass - SingleClear

Frame and

Reveal

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

Notes

Garage Door

Window Schedule - 6.5m LH

Window

No.

W1

W2

W3

W4

W5

W6

W7

W8

W9

W10

Type

AS1812T

AS1808T

AS0918

AS0906

AS1824T

AF0616

AS1216

AS0612

AS0606

AS0624

Window Size

Height

1,800

1,800

900

900

1,800

600

1,200

600

600

600

Width

1,210

850

1,810

610

2,410

1,570

1,570

1,210

610

2,410

Plan

View

AS1812T

AS1808T

AS0918

AS0906

AS1824T

AF0616

AS1216

AS0612

AS0606

AS0624

Elev.

ViewGlazing

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Frame and

Reveal

240mm BV

240mm BV

240mm BV

240mm BV

240mm BV

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

Notes

Page 17: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

17

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

Door Schedule - 6.5m RH - Reduced

Door

No.

D1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D11

D12

D13

D14

D15

D16

D17

Type

External HungDoor

Sliding Door

Hung Door

Sliding RobeDoors

Hung Door

Hung Door

Hung Door

Sliding Door

Hung Door

Sliding Robedoors

Hung Door

Hung Door

Hung Door

Hung Door

Hung Door

Hung Door

External HungDoor

Door Size

Height

2,040

2,100

2,040

2,100

2,040

2,040

2,040

2,100

2,040

2,100

2,040

2,040

2,040

2,040

2,040

2,040

2,040

Width

920

2,410

820

1,600

720

820

720

2,170

820

1,500

820

720

720

820

720

720

820

Plan

View

SD 2124

SD 2122

Elev.

ViewGlazing

Glass - SingleClear

Glass - SingleClear

Frame and

Reveal

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

Notes

Garage Door

Window Schedule - 6.5m RH - Reduced

Window

No.

W1

W2

W3

W4

W5

W6

W7

W8

W9

W10

Type

AS1808T

AS1812T

AS0918

AS0906

AS1824T

AF0616

AS1216

AS0612

AS0606

AS0624

Window Size

Height

1,800

1,800

900

900

1,800

600

1,200

600

600

600

Width

850

1,210

1,810

610

2,410

1,570

1,570

1,210

610

2,410

Plan

View

AS1808T

AS1812T

AS0918

AS0906

AS1824T

AF0616

AS1216

AS0612

AS0606

AS0624

Elev.

ViewGlazing

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Frame and

Reveal

240mm BV

240mm BV

240mm BV

240mm BV

240mm BV

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

Notes

Page 18: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

18

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

Door Schedule - 4.5m - Type A

Door

No.

D1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D11

D12

D13

D14

Type

External HungDoor

Sliding Door

Hung Door

Hung Door

Hung Door

Sliding Door

Hung Door

Hung Door

Sliding Robe

doors

Hung Door

Hung Door

Hung Door

Sliding Robedoors

External HungDoor

Door Size

Height

2,040

2,100

2,040

2,040

2,040

2,100

2,040

2,040

2,100

2,040

2,040

2,040

2,100

2,040

Width

820

3,600

920

720

720

2,410

720

420

2,000

720

720

820

2,400

820

Plan

View

SXD 2136

SD 2124

Elev.

ViewGlazing

Glass - SingleClear

Glass - SingleClear

Frame and

Reveal

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

Notes

Garage Door

Window Schedule - 4.5m - Type A

Window

No.

W1

W2

W3

W4

Type

AS1812T

AS1808T

AS1806T

AS0624

Window Size

Height

1,800

1,800

1,800

600

Width

1,210

850

610

2,410

Plan

View

AS1812T

AS1808T

AS1806T

AS0624

Elev.

ViewGlazing

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Frame and

Reveal

240mm BV

240mm BV

240mm BV

90mm TF

Notes

Page 19: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

19

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

Door Schedule - 4.5m - Type B

DoorNo.

D1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D11

D12

D13

D14

Type

External HungDoor

Sliding Door

Hung Door

Hung Door

Hung Door

Sliding RobeDoors

Hung Door

Hung Door

Sliding Robedoors

Hung Door

Hung Door

Hung Door

Sliding Robedoors

External HungDoor

Door Size

Height

2,040

2,100

2,040

2,040

2,040

2,100

2,040

2,040

2,100

2,040

2,040

2,040

2,100

2,040

Width

820

3,600

920

720

720

2,410

720

420

2,000

720

720

820

2,400

820

PlanView

SXD 2136

SD 2124

Elev.View

Glazing

Glass - SingleClear

Glass - SingleClear

Frame andReveal

240mm BV

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

90mm TF

Notes

Garage Door

Window Schedule - 4.5m - Type B

WindowNo.

W1

W2

W3

W4

Type

AS1812T

AS1808T

AS1206

AS0624

Window Size

Height

1,800

1,800

1,200

600

Width

1,210

850

610

2,410

PlanView

AS1812T

AS1808T

AS1206

AS0624

Elev.View

Glazing

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Glass - Single Clear

Frame andReveal

240mm BV

240mm BV

90mm TF

90mm TF

Notes

Page 20: 2 PROPOSED SITE PLAN Layout - Amazon Web Services · proposed site plan benching plan site analysis plan stormwater concept plan shadow diagrams ... (below red gauge line) backfill

SMOKE ALARM AS 3786-1993

NOTES: BOUNDARY SETBACKS MUST BE VERIFIED BY A

REGISTERED SURVEYOR BEFORE COMMENCEMENT OF

ANY BUILDING WORK. ALL WORK TO BE CARRIED OUT IN

ACCORDANCE WITH THESE DRAWINGS, COUNCIL

REQUIREMENTS, RELEVANT CODES & STANDARDS. LEVELS

SHOWN ARE BASED ON CONTOUR SURVEY PREPARED BY A

REGISTERED SURVEYOR. DRAWINGS ARE TO BE READ IN

CONJUNCTION WITH SPECIFICATIONS PROVIDED &

ENGINEERS DETAILS. WHERE ENGINEERS STRUCTURAL

DRAWINGS ARE REQUIRED THE ENGINEERS PLAN WILL TAKE

PREFERENCE TO THESE DRAWINGS. IN THE EVENT OF ANY

ALTERATIONS OR DISCREPANCIES, NOTIFY WISDOM HOMES

IMMEDIATELY. FIGURED DIMENSIONS TO BE READ IN

PREFERENCE TO SCALING & TO BE CHECKED & VERIFIED

BEFORE WORK IS COMMENCED.

JOB No:

BAR427LGA:

DESIGN:

FACADE:

CAMPBELLTOWN

CUSTOM

EXHAUST FANPROJECT:

PROPOSED BRICK VENEER DWELLINGCLIENT:

ADDRESS:

DRAWN:

PLOT DATE:

SLAB CLASS:

LW

22-05-18

VARIOUS CUSTOM

'H1' CLASS

REVISION SCHEDULE

DESCRIPTION DATEISSUE DRAWN

*COPYRIGHT OF PLANS AND DOCUMENTATION

REMAIN THE EXCLUSIVE PROPERTY OF

WISDOM PROPERTIES GROUP PTY LTD T/A

WISDOM HOMES. BUILDERS LIC. No 131951C.

A BASIX PLANS LW 16/05/18

B DA SUBMISSION PLANS LW 18/05/18

- - - -

- - - -

- - - -

- - - -

D.A/C.C

LODGEMENT:

20

SHEET:DRAFT

DP No:

V18

FILE PATH: T:\_WISDOM PROJECTS\New Breeze Estate - Bardia\Lot 427 - (6x) Arthur Allen Dr.pln

NOTES:* REFER TO ENGINEERS DETAILS FOR ALL EXPANSION JOINT LOCATIONS.

* REFER TO ENGINEERS DETAILS FOR ALL STEEL BEAM AND FLOOR JOIST

LOCATIONS AND DIRECTIONS.

* REFER TO TRUSS MANUFACTURERS DETAILS FOR ALL FLOOR JOIST SIZES

AND DIRECTIONS.

* REFER TO A/C DETAILS FOR A/C DUCT POSITIONS.

* A/C DUCT LOCATIONS MAY NEED TO CHANGE DUE TO CONSTRUCTION

REQUIREMENTS (JOIST LOCATION, STRUCTURAL BEAMS ETC).

* FLOOR FINISHES AS SELECTED AS PER TENDER.

* STAIRS TO MEET THE MINIMUM SLIP RESISTANCE REQUIREMENT OF PART

3.9.1.3 of BCA 2015 WHEN TESTED IN ACCORDANCE WITH AS4586-2013

Lot No.427 Arthur Allen Drive

Bardia

DAHUA GROUP AUSTRALIA

COLOUR SELECTION PAGE