3
Specifications Specifications & features are subject to change without notice. All specifications at ambient of 25 °C, unless specified otherwise. Application areas Performance CAT#367R2/P1/3/ www.radix.co.in Head Mount, 2-wire, Isolated, with HART protocol PERFORMANCE CHARACTERISTICS Response time 1 s Reference operating Calibration temperature : conditions 23 °C (73.4 °F) ±5K Long term stability £ 0.05% / year Switch on delay £ 5s Ambient temperature Negligible effect Load effect Negligible Power supply effect Negligible Resolution 0.3 µA Maximum measured error See Table 2 ENVIRONMENTAL CONDITIONS Ambient temperature -40 to 85 °C (-40 to 185 °F) limits -20 to 70 °C (-4 to 158 °F) Storage temperature -40 to 100 °C (-40 to 212 °F) Condensation Allowable Degree of protection IP20 Shock and vibration 4g/2 to 150 Hz as per IEC 60 068-26 resistance Electromagnetic Interference immunity and interference compatibility(EMC) emission according to GB/T17626.2- 1998), compliance with IEC 61000-4- 3:1995 MOC Plastic Weight Approx. 150g OTHER INPUT OUTPUTS ISOLATION POWER SUPPLY Input type Thermocouple B, E, J, K, N, R, S, T RTD Pt100, Pt500, Pt1000, Cu50, Cu100 Resistance 0~400 W, 0~2000 W, 0~10000 W Linear voltage -10~75 mV, -100~100 mV, -100~500 mV, -100~2000 mV Range limits See Table 1 Output signal 4~20 mA Load Input/output relation Temperature linear, resistance linear, voltage linear Mutual isolation between 2000 V AC RMS, 50 hz / 1 minute input, output Supply voltage U = 7.5 to 45 VDC b (reverse polarity protected) U = 10.5 to 45 VDC b MONITORING Sensor break detection, Upscale ~ 20.8 mA, selectable Downscale ~ 3 .8 mA Max. (U - 7.5V)/0.0208A b Max. (U - 10.5V)/0.0208A b · Inputs : Resistance thermometers (RTD), thermocouples (TC), resistance and voltage · Input selection : Via HART protocol · High performance, high reliability · Digital communication · Self-diagnostics function · Backlit LCD display with bargraph SCC631 2-wire, HART Temperature Transmitter Head mounted temperature transmitter with HART protocol for converting various input signals into a scalable 4 to 20 mA analogue output signal Inputs : Resistance thermometers(RTD) thermocouples (TC) Resistance Voltage Ÿ Universal settings with HART protocol for various input signals Ÿ 2-wire technology, 4~20 mA analog output Ÿ High accuracy in total ambient temperature range Ÿ Galvanic isolation Ÿ An internal temperature sensor for active temperature compensation Ÿ Wide voltage supply range Ÿ Customer specific measurement range settings Ÿ Multiparametric backlight rotatable LCD display Ÿ Expanded resistance input (max 10 KW) Ÿ Expanded voltage input (max 2000 mV) Ÿ No external power supply for configuration with USB interface Ÿ Simple and user friendly software

2-wire, HART Temperature Transmitter SCC631 Head Mount, 2 …3.imimg.com/.../MY-6251142/hart-temperature-transmitter.pdf · 2020-01-16 · 2-wire, HART Temperature Transmitter SCC631

  • Upload
    others

  • View
    10

  • Download
    2

Embed Size (px)

Citation preview

Page 1: 2-wire, HART Temperature Transmitter SCC631 Head Mount, 2 …3.imimg.com/.../MY-6251142/hart-temperature-transmitter.pdf · 2020-01-16 · 2-wire, HART Temperature Transmitter SCC631

SpecificationsSpecifications & features are subject to change without notice. All specifications at ambient of 25 °C, unless specified otherwise.

Application areas Performance

CAT#367R2/P1/3/

www.radix.co.in

Head Mount, 2-wire, Isolated,with HART protocol

PERFORMANCE CHARACTERISTICSResponse time 1 sReference operating Calibration temperature : conditions 23 °C (73.4 °F) ±5KLong term stability £ 0.05% / yearSwitch on delay £ 5sAmbient temperature Negligible effect Load effect NegligiblePower supply effect NegligibleResolution 0.3 µAMaximum measured error See Table 2 ENVIRONMENTAL CONDITIONSAmbient temperature -40 to 85 °C (-40 to 185 °F) limits -20 to 70 °C (-4 to 158 °F)Storage temperature -40 to 100 °C (-40 to 212 °F)Condensation AllowableDegree of protection IP20Shock and vibration 4g/2 to 150 Hz as per IEC 60 068-26 resistanceElectromagnetic Interference immunity and interference compatibility(EMC) emission according to GB/T17626.2-

1998), compliance with IEC 61000-4-3:1995

MOC PlasticWeight Approx. 150g

OTHER

INPUT

OUTPUTS

ISOLATION

POWER SUPPLY

Input type Thermocouple B, E, J, K, N, R, S, T

RTD Pt100, Pt500, Pt1000, Cu50, Cu100Resistance 0~400 W, 0~2000 W, 0~10000 W Linear voltage -10~75 mV, -100~100 mV,

-100~500 mV, -100~2000 mV Range limits See Table 1

Output signal 4~20 mALoad

Input/output relation Temperature linear, resistance linear, voltage linear

Mutual isolation between 2000 V AC RMS, 50 hz / 1 minute input, output

Supply voltage U = 7.5 to 45 VDCb

(reverse polarity protected) U = 10.5 to 45 VDCb

MONITORINGSensor break detection, Upscale ~ 20.8 mA, selectable Downscale ~ 3 .8 mA

Max. (U - 7.5V)/0.0208A b

Max. (U - 10.5V)/0.0208A b

· Inputs : Resistance thermometers (RTD),thermocouples (TC), resistance and voltage

· Input selection : Via HART protocol

· High performance, high reliability

· Digital communication

· Self-diagnostics function

· Backlit LCD display with bargraph

SCC6312-wire, HART Temperature Transmitter

Head mounted temperature transmitter with HART protocol for converting various input signals into a scalable 4 to 20 mA analogue output signal

Inputs : Resistance thermometers(RTD)thermocouples (TC)ResistanceVoltage

Ÿ Universal settings with HART protocol for various input signalsŸ 2-wire technology, 4~20 mA analog outputŸ High accuracy in total ambient temperature rangeŸ Galvanic isolationŸ An internal temperature sensor for active temperature compensationŸ Wide voltage supply rangeŸ Customer specific measurement range settingsŸ Multiparametric backlight rotatable LCD displayŸ Expanded resistance input (max 10 KW)Ÿ Expanded voltage input (max 2000 mV)Ÿ No external power supply for configuration with USB interfaceŸ Simple and user friendly software

Page 2: 2-wire, HART Temperature Transmitter SCC631 Head Mount, 2 …3.imimg.com/.../MY-6251142/hart-temperature-transmitter.pdf · 2020-01-16 · 2-wire, HART Temperature Transmitter SCC631

Inputs TypeMinimum

Measurement Ranges

Pt100Pt500Pt1000

*Ni100*Ni500*Ni1000

B ( P tRh30-PtRh6)E ( N iCr-CuNi)J ( F e-CuNi)K ( N iCr-Ni)N ( N iCrSi-NiSi)R ( P tRh13-Pt)S ( P tRh10-Pt)T ( C u-CuNi)

Resistance

Resistancethermometer(RTD)

Thermocouples(TC)

Voltage Millivolt

Cu50Cu100

Measurement ranges

10K10K10K

10K10K

10K10K10K

500K50K50K50K50K500K500K50K

-10 to 75mV -100 to 100mV -100 to 500mV -100 to 2000mV

5mV5mV6mV20mV

Maximum measured error

Type Measurement accuracy

Resistancethermometer RTD

Thermocouple TC

Pt100, Ni100Pt500, Ni500Pt1000, Ni1000Cu50Cu100

typ.0.5K or 0.08%typ.1.0K or 0.08%typ.2.0K or 0.08%

K, J, T, ENS, B, R

0.2K or 0.08%0.5K or 0.20%0.3K or 0.12%0.2K or 0.08%0.3K or 0.12%

Resistance

Voltage

-10 to 75mV -100 to 100mV -100 to 500mV-100 to 2000mV

SCC6312-wire, HART Temperature Transmitter

Table 1

Table 2

CAT#367R2/P2/3/

www.radix.co.in

-200 °C to 850 °C (-328 °F to 1562 °F)-200 °C to 250 °C (-328 °F to 482 °F)-200 °C to 250 °C (-328 °F to 482 °F)

-60 °C to 180 °C (-76 °F to 356 °F)-60 °C to 180 °C (-76 °F to 356 °F)-60 °C to 150 °C (-76 °F to 302 °F)

-50 °C to 150 °C (-58 °F to 302 °F)-50 °C to 150 °C (-58 °F to 302 °F)

0 to 400 W0 to 2000 W

± 0.1 W or 0.08%± 1.5 W or 0.12%± 7.5 W or 0.20%

0 to 1820 °C (32 to 3308 °F)-270 to 1000 °C (-454 to 1832 °F)-210 to 1200 °C (-346 to 2192 °F)-270 to 1372 °C (-454 to 2501 °F)-270 to 1300 °C (-454 to 2372 °F)-50 to 1768 °C (-58 to 3214.4 °F)-50 to 1768 °C (-58 to 3214.4 °F)-270 to 400 °C (-454 to 752 °F)

10 W20 W100 W

Resistance W

*a= 5000 ppm / K or 6180 ppm / KConnection type : 2/3/4-wire connectionSensor current : 0.5 mA

± 20 mV or 0.08%± 20 mV or 0.08%± 30 mV or 0.08%± 50 mV or 0.08%

Page 3: 2-wire, HART Temperature Transmitter SCC631 Head Mount, 2 …3.imimg.com/.../MY-6251142/hart-temperature-transmitter.pdf · 2020-01-16 · 2-wire, HART Temperature Transmitter SCC631

www.radix.co.inRadix Electrosystems Pvt Ltd, B-14, 2nd Floor, Ghanshyam Indl Estate, Veera Desai Road, Andheri (West), Mumbai - 400 053, IndiaTel : + 91 22 42537777 · Fax : + 91 22 42537700 · Email : [email protected] · www.radix.co.in

AN ISO 9001:2008 COMPANY

INSTRUMENTS T : + 91 22 42537777 x 701 F : + 91 22 E : [email protected]

SENSORS T : + 91 22 x 732 F : + 91 22 E : [email protected]

GAUGES T : + 91 22 x 733 F : + 91 22 E : [email protected]

AUTOMATION C : 0-9322405471 E : [email protected]

42537700

42537777 42537700

42537777 42537700

C : 0-9324319150

www.radix.co.in

2-wire, HART Temperature Transmitter SCC631

CAT#367R2/P3/3/

Dimensions

Electrical connections

A. Power supply, HART programmer

iPAQ

PC

PDA PDA

A

7.5 to 45 V10.5 to 45V

1

2

HART modem

ORDER CODE 2281

B. How to connect a sensor