43
Page 1 of 43 ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN) CAN/ULC-S101-07 $190.00 CAN/ULC-S101-07 $190.00 CAN/ULC-S102-07 $175.00 CAN/ULC-S102-07 $175.00 CAN/ULC-S102.2-07 $150.00 CAN/ULC-S102.2-07 $150.00 CAN/ULC-S102.3-07 $150.00 CAN/ULC-S102.3-07 $150.00 CAN/ULC-S102.4-07 $150.00 CAN/ULC-S102.4-07 $150.00 CAN4-S103-1983(R2000) 13.220.50 $110.00 CAN4-S103-1983(R2000) 13.220.50 $110.00 13.220.50 $110.00 CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS Standard Methods of Fire Endurance Tests of Building Construction and This Standard covers fire endurance tests applicable to walls, partitions, floors, roofs, ceilings, columns, beams, and girders, as well as to some components of these building sub-assemblies. It is the intent that the fire 13.220.50 19.040 Méthodes normalisées d'essai de résistance au feu pour les bâtiments et les matérieux de construction La présente norme porte sur les essais de résistance au feu effectués sur les murs, les cloisons, les planchers, les toits, les poteaux, les poutres, les poutrelles et sur certains éléments de ces sous ensembles de construction. La période de résistance au feu établie par cette méthode d'essai est une façon d'indiquer le rendement de 13.220.50 19.040 Method of Test for Surface Burning Characteristics of Building Materials and Assemblies This method of test for surface burning characteristics of building materials is applicable to any type of building material that, by its own structural qualities or the manner in which it is applied, is capable of supporting itself in position or may be supported in the test furnace as described in this standard or in a 13.220.50 19.040 Méthode d'essai normalisée caractéristiques de combustion superficielle des matériaux de La présente méthode d'essai permettant d'établir les caractéristiques de combustion des matériaux de construction s'applique à tous les types de matériaux de construction qui, par leurs propres qualités structurales ou par la façon dont ils sont appliqués, sont en mesure de demeurer en position de façon autonome ou peuvent être soutenus dans 13.220.50 19.040 Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies This Standard is applicable to the finished surface or covering of a floor extending to a maximum depth of 65 mm. This method is also applicable to the following: A Materials which cannot be tested as described in Clause 1.1 of CAN/ULC-S102 without the use of supporting material that is not representative of the intended installation; B Materials which, when tested in the manner described in Clause 1.1 of CAN/ULC-S102, melt and drip, or otherwise disintegrate and continue to burn on the floor of the test chamber; 13.220.40 13.220.50 19.040 91.180 Méthode d'essai normalisée caractéristiques de combustion superficielle des revêtements de sol et des divers matériaux et assemblages La présente norme s'applique à une surface finie ou à un revêtement de sol d'une épaisseur maximale de 65 mm. Cette méthode peut aussi s'appliquer aux matériaux suivants : A Matériaux qui ne peuvent être soumis à l'essai, comme le décrit la section 1.1 de la norme CAN/ULC S102, sans l'utilisation d'un matériau de soutien qui n'est pas représentatif de l'installation visée; B Matériaux qui, lorsqu'ils sont soumis à l'essai de la manière décrite à la section 1.1 de la norme CAN/ULC S102, fondent et dégouttent, ou se désintègrent et continuent de brûler 13.220.40 13.220.50 19.040 91.180 Standard Method of Fire Test of Light Diffusers and Lenses This test method is applicable to materials employed in light diffusers and lenses. The testing procedure described herein is intended to assess the propensity of material employed in light diffusers and lenses to fall from its installed position before igniting when subjected to test fire exposure conditions in CAN/ULC-S102, 13.220.50 19.040 91.160.10 Méthode d'essai normalisée de résistance au feu pour les diffuseurs et verres d'appareils d'éclairage La présente méthode d'essai s'applique aux matériaux utilisés dans les diffuseurs et verres d'appareils d'éclairage. La procédure d'essai décrite aux présentes vise à évaluer l'aptitude du matériau utilisé dans les diffuseurs et verres d'appareils d'éclairage à tomber de sa position initiale avant de s'enflammer lorsqu'il est soumis aux conditions 13.220.50 19.040 91.160.10 Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring and Cables This test method is for use in determining values of flame propagation distance and smoke optical density for electrical and optical-fibre cables that are to be installed in ducts, plenums, and other spaces used for environmental air without the cables being enclosed in metallic raceways in those spaces. This method also determines values of flame propagation distance and smoke optical density for electrical and optical -fibre cables with combustible jackets or sheathes to determine their acceptability for use in buildings of non-combustible construction. Although this method utilizes the same test apparatus as in CAN/ULC-S102, Standard Methods of Test for 13.220.40 19.040 29.060 Méthode d'essai normalisée caractéristiques de résistance au feu et à la fumée des fils et câbles électriques Cette méthode d'essai est utilisée pour déterminer les valeurs de distance de propagation de la flamme et de densité optique de la fumée des câbles électriques et des câbles de fibres optiques qui doivent être installés dans les conduits, les plénums et les autres espaces utilisés pour l'air environnemental sans que les câbles qui se trouvent dans ces espaces ne soient protégés par des canalisations métalliques. Cette méthode permet également de déterminer les valeurs de distance de propagation de la flamme et de densité optique de la fumée des fils et câbles électriques et des câbles de fibres optiques à gaine ou enveloppe combustible pour déterminer s'ils sont autorisés dans des bâtiments de construction incombustible. Bien que la présente méthode utilise le même appareil d'essai que celui décrit dans la 13.220.40 19.040 29.060 Standard Specification For “Tin-Clad” Fire Doors Meeting The Performance Required By S104 These Requirements cover the design and construction of "tin-clad" fire doors which have demonstrated in fire tests, fire performance properties sufficient to warrant their use in closure assemblies having a fire protection rating of up to and including 3 h, when tested in accordance with the Standard Method for Sépecification normalisée pour portes coupe-feu à revêtement métallique satisfaisant aux exigences de la norme Les présentes exigences portent sur la conception et la fabrication des portes coupe-feu à revêtement métallique qui ont démontré, lors des essais de comportement au feu, une résistance suffisante pour justifier leur utilisation dans les ensembles ayant un degré pare-flammes d'au plus 3 h, lorsqu'ils sont mis à l'essai conformément à la norme CAN4- S104, "Méthode normalisée d'essais de comportement au feu des portes". CAN4-S104-M80(R1985) Amendments 1-3 Standard Method for Fire Tests of Door Assemblies This fire test method is applicable to door assemblies of various materials and types of construction, for use in wall openings to retard the passage of fire. Tests made in conformity with this test method will register performance during the test exposure; but such tests shall not be construed as determining suitability for use after exposure to fire. It is the intent that tests made in conformity with this Standard will develop data to

2006 Ulc Publications Catalogue Wb Canada-Eng

Embed Size (px)

Citation preview

Page 1: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 1 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CAN/ULC-S101-07 $190.00

CAN/ULC-S101-07 $190.00

CAN/ULC-S102-07 $175.00

CAN/ULC-S102-07 $175.00

CAN/ULC-S102.2-07 $150.00

CAN/ULC-S102.2-07 $150.00

CAN/ULC-S102.3-07 $150.00

CAN/ULC-S102.3-07 $150.00

CAN/ULC-S102.4-07 $150.00

CAN/ULC-S102.4-07 $150.00

CAN4-S103-1983(R2000) 13.220.50 $110.00

CAN4-S103-1983(R2000) 13.220.50 $110.00

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

Standard Methods of Fire Endurance Tests of Building Construction and Materials

This Standard covers fire endurance tests applicable to walls, partitions, floors, roofs, ceilings, columns, beams,and girders, as well as to some components of these building sub-assemblies. It is the intent that the fireendurance period established by this test method indicates performance only during the fire exposure periodand shall not be construed as having determined suitability for use after fire exposure.

13.220.50

19.040

Méthodes normalisées d'essai de résistance au feu pour les bâtiments et les matérieux de construction

La présente norme porte sur les essais de résistance au feu effectués sur les murs, les cloisons, les planchers,les toits, les poteaux, les poutres, les poutrelles et sur certains éléments de ces sous ensembles de construction.La période de résistance au feu établie par cette méthode d'essai est une façon d'indiquer le rendement del'élément pendant une exposition au feu; elle ne détermine pas si l'élément peut être utilisé après son expositionau feu.

13.220.50 19.040

Method of Test for Surface Burning Characteristics of Building Materials and Assemblies

This method of test for surface burning characteristics of building materials is applicable to any type of building material that, by its own structural qualities or the manner in which it is applied, is capable of supporting itself in position or may be supported in the test furnace as described in this standard or in a manner comparable to its recommended use.

13.220.50

19.040

Méthode d'essai normalisée caractéristiques de combustion superficielle des matériaux de construction et assemblages

La présente méthode d'essai permettant d'établir les caractéristiques de combustion des matériaux de construction s'applique à tous les types de matériaux de construction qui, par leurs propres qualités structurales ou par la façon dont ils sont appliqués, sont en mesure de demeurer en position de façon autonome ou peuvent être soutenus dans le four d'essai comme décrit dans la présente norme ou d'une façon comparable à l'utilisation recommandée.

13.220.5019.040

Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies

This Standard is applicable to the finished surface or covering of a floor extending to a maximum depth of 65 mm.This method is also applicable to the following: A Materials which cannot be tested as described in Clause 1.1 of CAN/ULC-S102 without the use of supporting material that is not representative of the intended installation; B Materials which, when tested in the manner described in Clause 1.1 of CAN/ULC-S102, melt and drip, or otherwise disintegrate and continue to burn on the floor of the test chamber; C Materials that are designed for use in a relatively horizontal position with only its top surface exposed to air; or D Thermoplastic materials.

13.220.4013.220.50

19.04091.180

Méthode d'essai normalisée caractéristiques de combustion superficielle des revêtements de sol et des divers matériaux et assemblages

La présente norme s'applique à une surface finie ou à un revêtement de sol d'une épaisseur maximale de 65 mm.Cette méthode peut aussi s'appliquer aux matériaux suivants : A Matériaux qui ne peuvent être soumis à l'essai, comme le décrit la section 1.1 de la norme CAN/ULC S102, sans l'utilisation d'un matériau de soutien qui n'est pas représentatif de l'installation visée; B Matériaux qui, lorsqu'ils sont soumis à l'essai de la manière décrite à la section 1.1 de la norme CAN/ULC S102, fondent et dégouttent, ou se désintègrent et continuent de brûler sur le sol de la chambre d'essai; C Matériaux conçus pour être utilisés en position relativement horizontale où seulement la partie supérieure est exposée à l'air; ou D Matériaux thermoplastiques.

13.220.4013.220.50

19.04091.180

Standard Method of Fire Test of Light Diffusers and Lenses

This test method is applicable to materials employed in light diffusers and lenses. The testing procedure describedherein is intended to assess the propensity of material employed in light diffusers and lenses to fall from its installedposition before igniting when subjected to test fire exposure conditions in CAN/ULC-S102, as required in theNational Building Code of Canada 2005, Volume 1, Clause 3.1.13.4 1 (b).

13.220.50 19.040 91.160.10

Méthode d'essai normalisée de résistance au feu pour les diffuseurs et verres d'appareils d'éclairage

La présente méthode d'essai s'applique aux matériaux utilisés dans les diffuseurs et verres d'appareils d'éclairage.La procédure d'essai décrite aux présentes vise à évaluer l'aptitude du matériau utilisé dans les diffuseurs et verresd'appareils d'éclairage à tomber de sa position initiale avant de s'enflammer lorsqu'il est soumis aux conditionsd'exposition de l'essai de résistance au feu énoncées dans la norme CAN/ULC S102, conformément aux exigences

13.220.50 19.040 91.160.10

Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring and Cables

This test method is for use in determining values of flame propagation distance and smoke optical densityfor electrical and optical-fibre cables that are to be installed in ducts, plenums, and other spaces used forenvironmental air without the cables being enclosed in metallic raceways in those spaces. This methodalso determines values of flame propagation distance and smoke optical density for electrical and optical-fibre cables with combustible jackets or sheathes to determine their acceptability for use in buildings ofnon-combustible construction.

Although this method utilizes the same test apparatus as in CAN/ULC-S102, Standard Methods of Test forSurface Burning Characteristics, it does not determine surface burning characteristics of electrical wiringand cables.

This test method does not cover the construction requirements for cables or their electrical and other performance requirements.

13.220.40 19.040

29.060

Méthode d'essai normalisée caractéristiques de résistance au feu et à la fumée des fils et câbles électriques

Cette méthode d'essai est utilisée pour déterminer les valeurs de distance de propagation de la flamme et de densité optique de la fumée des câbles électriques et des câbles de fibres optiques qui doivent être installés dans les conduits, les plénums et les autres espaces utilisés pour l'air environnemental sans que les câbles qui se trouvent dans ces espaces ne soient protégés par des canalisations métalliques. Cette méthode permet également de déterminer les valeurs de distance de propagation de la flamme et de densité optique de la fumée des fils et câbles électriques et des câbles de fibres optiques à gaine ou enveloppe combustible pour déterminer s'ils sontautorisés dans des bâtiments de construction incombustible.

Bien que la présente méthode utilise le même appareil d'essai que celui décrit dans la norme CAN/ULC-S102 intituléeMéthode d'essai normalisée caractéristiques de combustion superficielle, elle ne détermine pas les caractéristiquesde combustion superficielle des fils et câbles électriques.

Cette méthode d'essai ne traite ni des exigences de construction des câbles ni de leurs exigences sur le plan électrique

13.220.40 19.040

29.060

Standard Specification For “Tin-Clad” Fire Doors Meeting The Performance Required By S104

These Requirements cover the design and construction of "tin-clad" fire doors which have demonstrated in fire tests, fire performance properties sufficient to warrant their use in closure assemblies having a fire protectionrating of up to and including 3 h, when tested in accordance with the Standard Method for Fire Tests of Door Assemblies, CAN4-S104.

Sépecification normalisée pour portes coupe-feu à revêtement métallique satisfaisant aux exigences de la norme CAN4-S104

Les présentes exigences portent sur la conception et la fabrication des portes coupe-feu à revêtement métallique qui ont démontré, lors des essais de comportement au feu, une résistance suffisante pour justifier leur utilisation dans les ensembles ayant un degré pare-flammes d'au plus 3 h, lorsqu'ils sont mis à l'essai conformément à la norme CAN4-S104, "Méthode normalisée d'essais de comportement au feu des portes".

Page 2: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 2 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

13.220.50 $110.00

13.220.50 $110.00

13.220.50 $110.00

13.220.50 $110.00

CAN4-S106-M80(R1985) $110.00

CAN4-S106-M80(R1985) $110.00

CAN/ULC-S107-03 $130.00

CAN/ULC-S107-03 $130.00

CAN/ULC-S109-03 $130.00

CAN/ULC-S109-03 $130.00

CAN/ULC-S110-07 91.140.30 $150.00

CAN4-S104-M80(R1985)Amendments 1-3

Standard Method for Fire Tests of Door Assemblies

This fire test method is applicable to door assemblies of various materials and types of construction, for use in wall openings to retard the passage of fire. Tests made in conformity with this test method will register performance during the test exposure; but such tests shall not be construed as determining suitability for use after exposure to fire. It is the intent that tests made in conformity with this Standard will develop data to enable regulatory bodies to determine the suitability of door assemblies for use in locations where fire resistance of a specified duration is required.

CAN4-S104-M80(R1985)Modifications 1-3

Méthode normalisée des essais de comportement au feu des portes

La présente méthode d'essai de comportement au feu s'applique auxportes de divers matériaux et types de construction, destinées à être utilisées dans des baies pratiquées dans les murs pourretarder le passage du feu. Les essais effectués conformément à la présente méthode permettront d'enrigistrer le rendement pendant l'éssai. Toutefois, ces essais ne déterminent pas si les portes sont encore utilisables après exposition au feu. Les essais effectués selon laprésente méthode fournissent des données qui permettent aux organismes de réglementation de déterminer si des portes peuventêtre utilisées dans des endroits où un degré de résistance au feu précis est exigé.  

CAN4-S105-M85(R1992)Amendment 1

Standard Specification for Fire Door Frames Meeting the Performance Required by CAN4-S104

These requirements cover frame assemblies having a fire protection rating of up to and including 3 h as determined by the Standard Method of Fire Tests of Door Assemblies, CAN4-S104.

CAN4-S105-M85(R1992)Modification 1

Norme sur les cadres de porte coupe-feu satisfaisant aux exigences de rendement de la norme CAN4-S104

Ces exigences portent sur les cadres des portes coupe-feu à battant simple. Ces cadres ont démontré, au cours des essais de résistance au feu, un rendement suffisant pour être utilisés avec des portes coupe-feu d'un indiceallant jusqu'à 3 h lorsqu'ils sont mis à l'essai conformément à la Méthode normalisée des essais de comportement au feu des portes, CAN4-S104M. Les cadres peuvent permettre l'installation de traverses ou de meneaux.

Standard Method for Fire Tests of Window and Glass Block Assemblies

This Method of Test applies to window and glass block assemblies and other light transmitting assemblies, for use in walls and partitions that are fire separations. Tests made in conformity with this test method will register performance during the test exposure and develop data to enable regulatory bodies to determine the suitability of window assemblies for use in wall and partition openings where fire protection is required. Such tests shall not be construed as determining suitability of window assemblies for continued use after fire exposure.

13.220.50 81.040.20

31.060.50

Méthode normalisée des essais de eomportement au feu des fenêtres et des briques de verre

La présente méthode d’essai de comportement au feu s’applique aux fenêtres et aux briques de verre ainsi qu’aux autres ensembles permettant la transmission lumineuse, utilisés dans les murs et cloisons formant des séparations coupe-feu. Les essais effectués conformément à la présente méthode permettront d’enregistrer le rendement pendant l’essai et de fournir des données permettant aux organismes de régle- mentation de déterminer les qualités requises des fenêtres pour les murs et les cloisons où une résistance au feu est nécessaire. Ces essais ne déterminent pas si les fenêtres sont encore utilisables après exposition au feu.

13.220.50 81.040.20

31.060.50

Methods of Fire Tests of Roof Coverings

The test methods described in this Standard are applicable to roof covering materials and are intended to measure the relative fire-performance characteristics of roof coverings when exposed to fire originating from sources outside a building on which they may be installed. They are applicable to roof coverings intended for installation on either combustible or non-combustible decks when applied as intended for use.

13.220.50 91.060.20

Méthodes normalisées d'essai de résistance au feu des matériaux de couverture

Les méthodes d’essai de la présente norme s’appliquent aux matériaux de couverture et servent a mesurer leurs caractéristiques de comportement au feu lorsqu’ils sont exposes a un feu dont l’origine est a l’extérieur du bâtiment sur lequel ils sont poses. Elles s’appliquent aux matériaux de couverture destines a être installes sue des platelages de toit combustible ou incombustibles, lorsqu’ils sont de la façon prévue.

13.220.50 91.060.20

Flame Tests of Flame Resistant Fabrics and Films

These requirements apply to the performance in flame-exposure tests of flame-resistant fabrics of natural, synthetic or combination of natural and synthetic fibers, or plastic films intended for such use as tents, awnings, draperies or decorations. The flame resistance of the fabric or film may be inherent in the material used or may be the result of chemical treatment to retard ignition and spread of flame.

59.080.30 83.140.10 13.220.40

13.220.50

Norme relative aux essais de comportement au feu des tissus et pellicules ininflammables

La présentes exigences s’appliquent a la tenue au feu lors d’essais d’exposition a la flamme des tissus ininflammables en fibres naturelles, synthétiques ou d’une combinaison des deux, ou de matières plastiques et qui sont destinées a la fabrication de tentes, d’auvents, de rideaux ou de décorations. La résistance au feu des tissus ou des pellicules peut être inhérente aux matériaux ou traitement chimique visant a retarder l’inflammation et la propagation de la flame.

59.080.30 83.140.10 13.220.40

13.220.50

Standard Methods of Test for Air Ducts

These test methods apply to materials for the fabrication of air duct systems for use in accordance with the requirements of the current edition of the National Building Code of Canada.The materials covered by these requirements include preformed lengths of flexible or rigid ducts, materials in the form of boards for field fabrication of lengths of rigid ducts, and preformed flexible connectors.

Page 3: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 3 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S110-07 91.140.30 $150.00

ULC-S111-07 $130.00

CAN/ULC-S112-M90 (R2001) $110.00

CAN/ULC-S112-M90(R2001) $110.00

$110.00

13.220.50 $110.00

$110.00

CAN/ULC-S113-07 $145.00

$145.00

Méthodes normalisées d’essai des conduits d'air

S'applique aux matériaux servant à la fabrication des conduitsd'air utilisés conformément aux exigences de l'édition en vigueur du Code national du bâtiment du Canada. Les matériaux auxquelss'appliquent ces exigences comprennent les sections de conduitsrigides ou flexibles fabriquées en usine, les matériaux sousforme de plaques servant à la fabrication de conduits rigides surplace et les raccords flexibles fabriqués en usine.

Standard Method of Fire Tests For Air Filter Units

These requirements cover air filter units of both washable and throw-away types for removal of dust and other airborne particles from air circulated mechanically in equipment and systems.

13.220.50 91.140.30

Standard Methods of Fire Test of Fire-Damper Assemblies

These requirements and methods of test apply to fire-damper assemblies rated ¾ h, 1 h, 1 ½ h, 2h, or 3h for use in air-conditioning and ventilating system ducts or openings (without ducts) piercing horizontally or vertically oriented fire separations where the fire separations are required to have a fire resistance rating of not more than 4h. These fire-damper assemblies are intended for installation in accordance with the provincial or municipal building regulations that are based on the National Building Code of Canada.

13.220.3019.040

91.140.30

Méthode normalisée d'essai de comportement au feu des registres coupe-feu

Les présentes exigences et méthodes d'essai s'appliquent auxregistres coupe-feu ayant une résistance au feu de 3/4h, 1h,1-1/2h, 2h ou 3h et utilisés dans les conduits ou ouvertures(sans conduits) des systèmes de conditionnement de l'air et deventilation traversant des séparations coupe-feu horizontales ouverticales lorsque ces séparations coupe-feu doivent avoir undegré de résistance au feu de 4h ou moins.

13.220.30 19.040

91.140.30

CAN/ULC-S112.1-M90(R2001)Amendment 1

Standard for Leakage Rated Dampers for Use in Smoke Control Systems

These requirements cover leakage rated dampers intended for use in heating, ventilating and air conditioning (HVAC) systems. Leakage rated dampers are intended to restrict the spread of smoke in HVAC systems that are designed to be automatically shutdown in the event of a fire or to control the movement of smoke within a building when the HVAC system is operational in engineered smoke control systems.

13.040 13.220.20 23.060

91.140.30

CAN4-S112.2-M84 Amendment 1

Standard Method of Fire Test of Ceiling Firestop Flap Assemblies

These requirements cover the test procedure for the performance evaluation of ceiling firestop flap assemblies which may or may not be part of an air diffusion device, intended for use in fire resistive floor-ceiling and roof-ceiling assemblies.

CAN4-S112.2-M84 (R2001)Modification 1

Méthode normalisée des essais de comportement au feu des clapets coupe-feu situés dans les plafonds

Les présentes exigences d'essai permettent d'évaluer le rendementdes clapets coupe-feu situés dans les plafonds qui peuvent fairepartie intégrante ou non de diffuseurs d'air destinés à êtreutilisés dans les en- sembles planchers-plafonds et toits-plafondsrésistants au feu.

13.220.50 91.060.30

Standard Specification for Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies

These requirements cover the design and construction of Wood Core Flush Doors, which have shown by fire tests to possess sufficient fire-retardant properties to warrant a 20 minute fire protection rating when testedin accordance with the Standard Method for Fire Tests of Door Assemblies, CAN/ULC-S104.

13.220.50 91.060.50

CAN/ULC-S113-07 Spécification de norme portes à âme de bois satisfaisant aux exigences de rendement de CAN/ULC-S104 pour les dispositifs de fermeture ayant un degré de résistance au feu de vingt minutes

Les présentes exigences portent sur la conception et laconstruction des portes planes à âme de bois qui ont subi desessais de résistance au feu démontrant qu'elles peuvent assurerune protection contre le feu de 20 minutes, ces essais étanteffectués en conformité avec la méthode normalisée d'essais decomportement au feu des portes CAN/ULC-S104.

13.220.50 91.060.50

Page 4: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 4 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S114-05 13.220.50 $130.00

CAN/ULC-S114-05 13.220.50 $130.00

CAN/ULC-S115-05 $150.00

CAN/ULC-S115-05 $150.00

$110.00

$110.00

$145.00

$145.00

CAN/ULC-S126-06 $145.00

CAN/ULC-S126-06 $145.00

CAN/ULC-S127-07 $175.00

CAN/ULC-S127-07 $175.00

$145.00

$145.00

$110.00

Standard Method of Test for Determination of Non-Combustibility in Building Materials

This Standard provides a means of determining the non-combustible nature of elementary building materials. It shall be applied to materials used in the construction of buildings. It does not apply to materials with a decorative or protective coating, or impregnation, or built up of laminations of dissimilar materials.

Méthode d’essai normalisée pour la détermination de l’incombustibilité des matériaux de construction

La présente norme permet de déterminer la nature non combustible des matériaux de construction de base. Elle s'applique aux matériaux utilisés dans la construction de bâtiments. Elle ne s'applique pas aux matériaux à revêtement décoratif ou protecteur, ou à imprégnation, ou faits de lamelles de matériaux dissemblables.

Standard Method of Fire Tests of Firestop Systems

This method of test is applicable to firestop systems with or without penetrating items. These firestop systems are intended for use in openings in fire resistive wall and floor assemblies and membranes forming part of an assembly required to have a fire resistance rating and linear openings between adjacent fire resistive floor assemblies, wall assemblies or both.

13.220.20 19.040

Méthode normalisée d'essai de comportement au feu des ensembles coupe-feu

La présente méthode d'essai s'applique aux dispositifs coupe-feu avec ou sans éléments passants. Ces dispositifs coupe-feu sont destinés à une utilisation dans les ouvertures d'éléments de murs et de planchers résistants au feu et de membranes faisant partie intégrante d'un ensemble, qui doit avoir un indice de résistance au feu, et des ouvertures linéaires entre éléments de planchers, ou éléments de murs adjacents résistants au feu, ou les deux.

13.220.20 19.040

CAN4-S117.1-M85(R1999)Amendments 1-2

Standard Method of Test for Flame Resistance – Methenamine Tablet Test for Textile Floor Coverings

This method determines the flammability of finished textile floor covering materials when exposed to an ignition source (methenamine tablet) under specified conditions.This method is applicable to all types of textile floor coverings regardless of fibre type or method of construction.This document does not purport to address all the safety aspects associated with its use. Anyone using this test method has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any existing applicable regulatory requirements prior to its use.

13.220.50 59.080.60

CAN4-S117.1-M85 (R1999) Modifications 1-2

Méthode d’essai normalisée: Résistance à l'information - essai à la tablette de méthénamine des revêtements de sol textiles

La présente méthode a pour objet de déterminer l'inflammabilité desrevêtements de sol textiles, à l'état fini, lorsqu'ils sont exposés à unesource d'allumage (tablette de méthénamine), dans des conditions prescrites. La présente méthode s'applique à tous les types de revêtements de soltextiles quels que soient leur com- position ou le procédé utilisé pour leurfabrication. Cette méthode décrit l'essai d'un seul spécimen. Elle doit être utiliséeavec un plan d'échantillonnage valable du point de vue statistique et basé surun minimum de 10 spécimens. Remarque : En vertu des exigences de la Loi sur les produits dangereux régissant les revêtements de sol mous, le nombre de spécimens qui doivent être éprouvés est fixé par la norme CAN/CGSB-4.155M, Résistance à l'inflammabilité des revêtements de sol mous - Plans d'échantillonnage.(Modification n° 1, janvier 1992, ajout de l'article 1.4) Cette méthode d'essai peut nécessiter l'utilisation de matériaux oud'équipement, ou les deux, pouvant être dangereux. Ce document n'a pas pour objet d'aborder toutes les questions de sécurité liées à cette méthode. Avantd'utiliser cette dernière, toute personne doit consulter les pouvoirs intéressés et établir des mesures appropriées de sécurité et de protection dela santé, tout en se conformant aux exigences obligatoires pertinentes envigueur.(Modification n° 1, janvier 1992, ajout de l'article 1.4)

13.220.50 59.080.60

CAN/ULC-S124-06 Standard Method of Test for the Evaluation of Protective Coverings for Foamed Plastic

These requirements cover the temperature transmission performance of a protective covering over foamed plastic when the assembly is subjected to a standard fire exposure condition.

13.220.50 91.180

CAN/ULC-S124-06 Méthode d’essai normalisée évaluation des revêtements protecteurs des mousses plastiques

Permet d'évaluer le rendement, dans la transmission detempérature, des revêtements protecteurs appliqués sur lesmousses plastiques lorsqu'ils sont soumis aux conditionsd'exposition au feu normalisées.

13.220.5091.180

Standard Method of Test for Fire Spread Under Roof-Deck Assemblies

This test method provides a means of measuring the contribution of roof-deck assembly components to the spread of fire on the underside of the roof deck.

13.220.50 91.060.20

Méthode normalisée d'essai propagation des flammes sous les platelages de toits

Permet d'établir dans quelle mesure les composants de platelagesde toits contribuent à la propagation des flammes sur la faceinférieure des platelages.

13.220.50 91.060.20

Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials

This method of test for flammability characteristics is applicable to certain low density insulating materials that donot melt or drip during exposure to fire (see Appendix A). It is used in establishing the Flame SpreadClassification for those foamed plastics whose flammability assessment by CAN/ULC-S102 requires the use of therate formula FSV = 92.5 d/t but where the necessary parameters ('d' & 't') for use in the formula are difficult to define.

The purpose of this test is to determine the comparative burning characteristics of the material under test by exposingthe material in a corner wall configuration to a test fire.

13.22.050 19.040

91.060.10

Méthode d'essai normalisée d'allumageen coin visant à déterminer les caractéristiques d'inflammabilité des matériaux de construction en mousse plastique à l'épreuve de la fusion

La présente méthode d'essai visant à déterminer les caractéristiques d'inflammabilité s'applique à certains matériauxisolants basse densité qui ne fondent pas ou qui ne dégouttent pas pendant l'exposition au feu (se reporter à l'annexeA). Elle est utilisée pour établir l'indice de propagation de la flamme des mousses plastiques dont l'évaluation del'inflammabilité lors de l'essai décrit dans la norme CAN/ULC S102 exige l'utilisation de la formule de calcul de l'indiceVPF = 92,5 d/t, mais où les paramètres nécessaires (« d » et « t ») à utiliser dans la formule sont difficiles à définir.

Le présent essai vise à déterminer les caractéristiques de combustion comparatives du matériau soumis à l'essai en

13.22.050 19.040

91.060.10

CAN/ULC-S129-06 Standard Method Of Test For Smoulder Resistance Of Insulation (Basket Method)

This Standard applies to thermal insulation suitable for indoor use in building construction within the temperature range of -50 to 80 °C. The types of insulation materials which lend themselves to the evaluation using the method described in this Standard are: A) Loose fill, designed for pouring application; B)Loose fill, designed for blowing application with the aid of pneumatic equipment; C) Preformed products such as batts, roll boards and sheets; and D) Spray applied products.

13.220.50 19.040 91.120.10

CAN/ULC-S129-06 Méthode normalisée d'essai de larésistance à la combustion lente des isolants (méthode du panier)

La présente norme s'applique à des isolants thermiques utilisés à l'intérieur dans la construction de bâtiments où la température se situe entre –50 et 80 °C. Les types de matériaux isolants qui se prêtent à l'évaluation au moyen de la méthode décrite dans la présente norme sont les suivants : A) à bourrage lâche pour l'application manuelle; B) à bourrage lâche destiné au soufflage à l'aide d'un équipement pneumatique; C) produits préformés comme des panneaux semi-rigides, des rouleaux et des feuilles; et D) produits pulvérisés.

13.220.50 19.040 91.120.10

CAN/ULC-S130-M87(R1997)Amendment 1

Standard Method of Test for Ignition Resistance of Loose Fill Insulation (Cigarette Method)

This Standard applies to cellulose fibre loose fill thermal insulation suitable for indoor use in building construction within the temperature range of -50 to 80°C.

13.220.50 91.120.10

Page 5: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 5 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$110.00

$175.00

CAN/ULC-S132-07 $175.00

CAN/ULC-S130-M87 (R1997)Modification 1

Méthode normalisée d’essai de résistance à l’allumage de l’isolant thermique cellulosique à bourrage lâche (méthode de la cigarette)

La présente norme s'applique à l'isolant thermique cellulosique à bourragelâche utilisé à l'intérieur des bâtimentsà des températures comprises entre-50 et +80°C.1.2Tout isolant conforme à la présente norme, lorsque cela est précisé par le fabricant, convient aux deux modes d'application (c'est-à-dire déversement à lamain au soufflage à l'aide d'un équipement spécial).

13.220.50 91.120.10

CAN/ULC-S132-07 Standard For Emergency Exit And Emergency Fire Exit Hardware

These requirements cover emergency exit hardware, and emergency fire exit hardware that will actuate the latchingmechanism on a door to allow it to swing open when force is applied to the device.

13.220.20 91.060.50

Méthode d'essai normalisée des serrures antipaniques des issues de secours et des portes coupe feu

Les présentes exigences visent les serrures antipaniques des issues de secours et les serrures antipaniques desportes coupe feu qui actionnent le mécanisme de verrouillage d'une porte pour lui permettre de s'ouvrir lorsqu'uneforce est exercée sur le dispositif.

13.220.20 91.060.50

Page 6: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 6 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$130.00

$130.00

$110.00

$110.00

$180.00

CAN/ULC-S137-07 13.220.40 $220.00

CAN/ULC-S137-07 13.220.40 $220.00

CAN/ULC-S138-06 $205.00

CAN/ULC-S138-06 $205.00

ULC-S139-00 $110.00

$130.00

$130.00

CAN/ULC-S133-07 Standard Method of Tests for Door Closers Intended for Use with Swinging Doors

The purpose of CAN/ULC-S133-07 is to establish requirements for door closers intended for use with swinging doors infire separations and on exit doors. This Standard does not cover door closers equipped with hold‑open features. Thedoor closers covered by this Standard are intended for installation in accordance with the Standard for Fire Doors and+C47 Windows, NFPA No. 80. The door closers covered by this Standard are intended for installation on interior doors

21.080 91.060.50

CAN/ULC-S133-07 Norme sur les ferme-porte conçus pour être utilisés avec des portes battantes

La norme CAN/ULC-S133-07 vise à déterminer les exigences relatives aux ferme-porte conçus pour être utilisés avec lesportes battantes des séparations coupe-feu et des portes de sortie. La présente norme ne s'applique pas aux ferme-porte dotés de dispositifs de maintien en position ouverte. Les ferme-porte couverts par la présente norme sont conçuspour être installés conformément à la norme NFPA 80, Standard for Fire Doors and Windows. Les ferme-porte couvertspar la présente norme sont conçus pour être installés sur des portes intérieures et pour être montés à l'intérieur des

21.080 91.060.50

CAN/ULC-S134-92(R1998)

Standard Method of Fire Test of Exterior Wall Assemblies

This test method enables an assessment of the fire spread characteristics of non-load bearing exterior wall assemblies. The test determines the comparative burning characteristics of exterior wall assemblies by evaluating fire spread over the exterior surface, heat flow from the fire plume to the exterior surface, and fire spread within the test specimen.

13.220.50 19.040

91.060.10

CAN/ULC-S134-92(R1998)

Méthode normalisée des essais de comportement au feu des murs extérieurs

Cette méthode d'essai permet d'évaluer les caractéristiques de propagation des flammes des murs extérieurs non porteurs. L'essai détermine aussi les caractéristiques de combustion comparatives des murs extérieurs en évaluant les éléments suivants :A propagation des flammes sur la face extérieure;B flux de chaleur de la colonne de flammes à la face extérieure;C propagation des flammes dans le spécimen d'essai.

13.220.50 19.040

91.060.10

ULC-S135-04 Amendment 1

Standard Test Method for the Determination of Combustibility Parameters of Building Materials Using an Oxygen Consumption Calorimeter (Cone Calorimeter)

This test method determines combustibility parameters for the assessment of degree of combustibility of building materials by measuring the heat release and smoke production from specimens exposed to radiant heat using the test apparatus, specimen configurations and procedures described. This test method determines the amount of heat and smoke that may be contributed to a fire involving products made from the same material as that of the test specimen.

13.220.50 19.040

STANDARD METHOD OF TEST FOR FIRE GROWTH OF MATTRESSES (OPEN FLAME TEST)

The purpose of this test method is to investigate the ability of mattresses to resist rapid heat release by measuring specific fire test responses when the mattress or mattress set is subjected to a specified flaming ignition source under well ventilated conditions. This test method is applicable only to the finished mattresses and mattress sets and does not apply to testing of individual component materials used, such as ticking and upholstery materials, foams,cotton battings, etc... This test method does not provide information on the performance of a mattress or mattress set in other fire conditions or the contribution of the mattress to a developing fire condition.

MÉTHODE D'ESSAI NORMALISÉE POUR LA PROPAGATION DU FEU SUR LES MATELAS (ESSAI À LA FLAMME NUE)

La présente méthode d'essai vise à étudier la capacité d'un matelas à résister à un dégagement rapide de chaleur en mesurant les réactions spécifiques à l'essai de résistance au feu lorsqu'il est soumis à unesource d'inflammation prescrite dans des conditions de bonne aération. La présente méthode d'essai s'applique seulement à des matelas ou ensembles de matelas finis, mais ne convient pas aux essais sur desmatériaux de composants distincts, comme les housses à matelas, le rembourrage, les mousses, les ouates de coton, etc. La présente méthode d'essai ne fournit pas de renseignements sur la performance d'un matelas ou d'un ensemble de matelas dans des conditions de feu différentes ou quant à sa contribution à propager un feu.

Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration

This is a fire test response Standard that describes the test method used to determine the contribution to fire growth provided by a non-loadbearing insulated building panel installed in a sprinklered or unsprinklered room configuration. The insulated building panels investigated by this test method are of the factory-assembled type and intended for use as exterior or interior walls, ceilings or roofs. This Standard presumes that these panels are not backed by other materials or constructions in typical installation practice. This test method measures the time to flashover under specified test conditions. Provisions are made to measure ignitability, smoke obscuration, rate of fire growth and rate of heat release of the test panels. This test method is not intended to determine the fire resistance rating of insulated building panels. In addition, this test method does not investigate the toxic hazard posed by the products of combustion.

13.220.50 19.020

91.060.10

Méthode d'essai normalisée de la propagation du feu dans les panneaux de construction isolés d'une configuration de pièces à l'échelle réelle

Il s'agit d'une norme d'essai de résistance au feu. Le présent document décrit la méthode d'essai utilisée pour déterminer la contribution du panneau de construction isolé non porteur à la propagation du feu dans une configuration de pièce protégée ou non par un système de gicleurs. 1.2 Les panneaux de construction isolés faisant l'objet de cette méthode d'essai ont été fabriqués en usine et sont destinés à être utilisés pour la fabrication de murs extérieurs et intérieurs, de plafonds et de toits. Cette norme suppose qu'aucun contreparement fabriqué d'autres matériaux n'est posé sur les panneaux en question dans une situation d'installation type. 1.3 La présente méthode d'essai mesure le temps requis, dans des conditions précises, pour produire un embrasement général. Les dispositions nécessaires sont prises afin de mesurer l'inflammabilité, l'obscurcissement dû aux fumées, la vitesse de propagation du feu et le taux de chaleur émise des panneaux d'essai. 1.4 La présente méthode d'essai n'a pas été conçue afin de déterminer la résistance au feu des panneaux de construction isolés. De plus, cette méthode d'essai n'examine pas les risques de toxicité que présentent les produits de la combustion.

13.220.50 19.020

91.060.10

Standard Method of Fire Test for Evaluation of Integrity of Electrical Cables

The intent of this fire test method is to determine the integrity of electrical cables which are evaluated for their ability to maintain circuit integrity at a specified voltage potential relative to ground and other conductors. Leakage current per unit length of cable shall also be quantified.

13.220.50 29.060.20

CAN/ULC-S301-M88Amendments 1-4

Standard For Central And Monitoring Station Burglar Alarm Systems

This Standard covers requirements applicable to Central Station Facilities and Protection Service, Monitoring Station Facilities and Protection Service, Satellite Centres, Signal Processing Centres, and Bridging Centres. This Standard does not include requirements for hold‑up alarm systems or panic alarm devices.

13.310 13.320

CAN/ULC-S301-M88Modifications 1-4

Norme systèmes d'alarme antivol des postes centraux et des postes desurveillance

La présente norme renferme les exigences relatives au service deprotection et aux installations des postes centraux, au service de protectionet aux installations des postes de surveillance et aux postes satellites. Quel que soit le type de service de protection établi conformément à laprésente norme, les dispositifs qui protègent les propriétés individuelles sont également classés selon le degré de protection assuré à chaque emplacement.Les exigences concernant l'installation et la classification du degré de protection du matériel des systèmes d'alarme installés dans des locaux individuels sont publiées dans la norme ULC-S302-1974 intitulée «Installationet classification des systèmes d'alarme antivol des banques et desétablissements commerciaux» qui devrait être consultée par les installateurs de dispositifs d'alarme antivol.

13.310 13.320

Page 7: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 7 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$130.00

$130.00

$130.00

CAN/ULC-S303-M91 (R1999) $130.00

CAN/ULC-S304-06 $200.00

CAN/ULC-S304-06 $200.00

ULC-306-03 Intrusion Detection Units $130.00

CAN/ULC-S310-M91 (R1999) $130.00

CAN/ULC-S310-M91 (R1999) $130.00

ULC-S317-96 $110.00

ULC-S318-96 These requirements cover power supplies for use as components in burglar alarm systems. $110.00

CAN/ULC-S319-05 13.31

CAN/ULC-S319-05 13.31

CAN/ULC-S302-M91(R1999)Amendments 1-3

Standard for Installation and Classification of Burglar Alarm Systems for Financial and Commercial Premises, Safes And Vaults

These requirements apply to the installation of protective wiring and devices connected to burglar alarm systems on financial and commercial premises, safes and vaults. These requirements also include the classification of extent of protection installed at individual locations.

13.310

13.320 91.040.20

CAN/ULC-S302-M91(R1999)Modifications 1-3

Norme installation et classification des systèmes d'alarme antivol des banques,établissements commerciaux, coffre-forts et chambres fortes

Les présentes exigences visent l'installation du câblage et dispositifs deprotection raccordés aux systèmes d'alarme antivol de banques, d'établissementcommerciaux, de coffre-forts et de chambres fortes. Les présentes exigences renferment également les règles de classification du degré de protection à desendroits particuliers. Les systèmes d'alarme antivol sont classés suivant leur principe defonctionnement : poste central, poste de surveillance ou système local. Il seclassent également selon la catégorie particulière de propriété qu'ils sontdestinés à protéger, c'est-à-dire des établissements commerciaux, coffres-forts ou chambres fortes et des coffres-forts ou chambres fortes d'établissements financiers.

13.310 13.320

91.040.20

CAN/ULC-S303-M91(R1999) Standard for Local Burglar Alarm Units and Systems

These requirements cover design and construction, performance, and maintenance of local burglar alarm units and systems for use in mercantile premises, mercantile safes and vaults, and bank safes and vaults.

13.31013.32097.180

Norme dispositifs et systèmes d'alarme antivol locaux

Les présente exigences visent la conception, la construction, le rendementet l'entretien des dispositifs et des systèmes d'alarme antivol locaux destinésà être utilisés dans les établissements commerciaux, les coffres-forts et leschambres fortes des établissements commerciaux et des banques.

13.310 13.320

97.180

Signal Receiving Centre And Premise Burglar Alarm Control Units

This Standard covers construction and performance requirements for signal receiving centre burglar alarm control units, including signal receiving, recording and supervisory control units intended for permanent use within a signal receiving centre. It also covers associated burglar alarm control units to be installed within mercantile and banking premises and on safes and vaults for protection against burglary.

These requirements also serve as the basis of classification of signal receiving centre burglar alarm control units. Requirements covering complete control units are contained in CAN/ULC S301, Standard for Central and Monitoring Station Burglar Alarm Systems.

13.310 13.320

97.180

Postes de contrôle d'alarme antivol de la centrale de réception d'alarme et du local

La présente norme porte sur les exigences de construction et de rendement des postes de contrôle d'alarme antivol à la centrale de réception d'alarme, comprenant les dispositifs de réception des signaux, les dispositifs enregistreurs et les postes de surveillance destinés à être utilisés en permanence dans une centrale de réception d'alarme. La présente norme s'applique également aux dispositifs d'alarme antivol connexes destinés à être utilisés dans les établissements commerciaux, et les banques, les coffres forts et les chambres fortes contre les vols.

De plus, les présentes exigences permettent de classer les postes de contrôle d'alarme antivol des centrales de réception d'alarme. La norme CAN/ULC S301, Dispositifs d'alarme antivol des postes centraux et des postes de surveillance, renferme les exigences visant les systèmes de surveillance entiers.

13.310 13.320

97.180

These requirements cover intrusion-detection units for burglary protection signalling systems to be employed in outdoor or ordinary indoor (nonhazardous) locations to automatically indicate the presence of an intruder by actuating electrical control circuits.

13.310 97.180

Installation and Classification of Residential Burglar Alam Systems

These requirements apply to the installation of alarm protection products and devices connected to form a residential burglar alarm system. These requirements include the criteria for classifying the level of protection at an individual residence.

13.310 

Norme installation et classification des sytèmes d’alarme résidentiels contre le cambriolage

Les présentes exigences s'appliquent à l'installation de produits et dedispositifs d'alarme de protection raccordéspour constituer un systèmed'alarme résidentiel contre le cambriolage. Les présentes exigences comportent les critères de classification du niveau deprotection par rapport à une résidence donnée. Voir l'annexe A.

13.310 

Standard for Installation and Classification of Closed Circuit Video Equipment (CCVE) Systems for Institutional and Commercial Security Applications

These requirements apply to the installation of equipment and wiring of closed circuit surveillance cameras and associated video equipment.

33.160.40 13.310

Standard for Power Supplies for Burglar Alarm Systems

13.310 29.260.01

Electronic Access Control Systems

An electronic access control system is a system designed to grant to authorized persons entry to and/or exit from a controlled area and deny such entry and/or exit to non-authorized individuals by electrical, electronic or mechanical means. The extent of control of entry/exit may include the reporting and recording of related activity.

This standard defines the minimum requirements as they apply to the construction, performance and operation of such systems and/or accessory equipment as well as recommended characteristics to meet four levels of protection with Level I (lowest level-Class I equipment) to Level IV (highest-Class IV equipment). The various means of communication between the reader, the reader interface module, the access point actuator, the access point sensor, the access control unit and the monitoring console are described within the scope of this standard.

$210

$245 after Nov. 1, 2005

Systèmes électroniques de contrôle d’accès

Un système de contrôle d’accès est un système comportant divers composants électriques, électroniques ou mécaniques conçus pour permettre aux personnes autorisées et interdire aux personnes non autorisées d’entrer dans une zone protégée ou d’en sortir. Le contrôle des entrées et des sorties peut englober le signalement et la consignation des activités connexes.

La présente norme énonce les exigences minimales auxquelles doivent satisfaire ces systèmes et l’équipement auxiliaire sur le plan de la construction, de la performance et du fonctionnement ainsi que les caractéristiques qu’ils doivent posséder pour être en mesure d’assurer le niveau de protection voulu en allant du niveau I (le plus faible - Équipement de classe I) au niveau IV (le plus élevé - Équipement de classe IV). La norme décrit aussi les divers moyens de communication entre le lecteur, le module d’interface de lecteur, l’actionneur de point d’accès, le capteur de point d’accès, l’unité de contrôle d’accès et la console de surveillance.

$210

$245 Après le 1er

novembre 2005

Page 8: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 8 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$110.00

$110.00

CAN/ULC-S322-92 (R1998) $110.00

Burglary Resistant Safes $110.00

ULC-S327-98 $115.00

ULC-S328-98 $115.00

35.240.40 $110.00

ULC-S330-93 $110.00

13.310 $110.00

ULC-S333-93 Currency Dispensing Units $110.00

ULC-S334-98 $110.00

ULC-S337-98 Delayed-Action Timelocks 91.190 $115.00

CAN/ULC-S338-98 $130.00

CAN/ULC-S338-98 $130.00

CAN/ULC-S321-M91 Amendments 1-2

Standard for Burglary Resistant Vault Doors and Modular Panels

These requirements cover vault doors and vault modular panels (for use in the construction of vault floors, walls and ceilings), of the type intended for use in financial institutions, commercial, industrial and mercantile properties, and the like, and that are relied upon to protect the contents of enclosed spaces from burglary attack. Requirements for fire resistant rating of vaults and vault doors are outside the scope of this Standard and should be determined in accordance with Chapter 2 of the Supplement to the National Building Code of Canada or in accordance with ULC/ORD-C72A, Fire Resistance of Prefabricated Structure Supported Vaults.

These requirements are intended to establish the burglary resistant rating of vault doors and modular panels according to the length of time they withstand attack by common mechanical tools, electrical tools, cutting torches, or any combination of these means in the hands of experienced operators. These requirements do not cover attacks with the burning bar (thermal lance) or explosives.

13.310 91.060.50

CAN/ULC-S321-M91Amendment 1

Portes et panneaux modulaires antivol des chambres fortes

Les présentes exigences couvrent les portes et les panneaux modulaires deschambres fortes (utilisés pour la construction des planchers, des murs et desplafonds des chambres fortes) des établissements à vocation financière,commerciale et industrielle, ou à vocation similaire, et sur lesquelles on sefie pour la protection contre le cambriolage des biens qu'elles contiennent. NOTE : Les exigences relatives au niveau de résistance au feu ne font pas l'objet de la présente norme et doivent être déterminées comme le prescrivent le chapitre 2 du Supplément du Code national du bâtiment du Canada ou la norme ULC/ORD-C72A Fire Resistance of Prefabricated Stricture Supported Vaults. Les présentes exigences ont pour but d'établir le niveau de résistance aucambriolage des portes et des panneaux modulaires des chambres fortes enfonction du temps durant lequel ils résistent lors d'un essai d'intrusion àl'aide d'outils mécaniques usuels, d'outils électriques usuels, de chalumeauxd'oxycoupage ou de toute combinaison de ceux-ci lorsqu'ils sont utilisés pardes experts pour ce type d'essais. Le niveau de résistance est fonction de ladurée nette de travail qui est nécessaire pour réussir une intrusion et il estétabli comme suit : ClasseC1-30 Protection minimale de 30 minutesC2-60 Protection minimale de 60 minutesC2-90 Protection minimale de 90 minutesC3-120 Protection minimale de 2 heures1.3 Les présentes exigences ne couvrent pas les tentatives d'intrusion faites avec une lance à oxygène (lance thermique) ou avec des explosifs.

13.310 91.060.50

Vault Ventilators and Vault Ventilatating

These requirements cover emergency vault ventilators and vault-ventilating ports. Products covered by these requirements are intended for installation in vaults that are used for the storage of valuables, and that are protected by special security measures that cannot be forced using normal rescue equipment, but require waiting for a time lock or similar device to release entrapped individuals.

13.04013.31023.120

ULC-S324-93Amendment 1

These requirements cover burglary-resistant safes classified as follows: A. Tested on Six Sides: (i) Residential Safe; (ii) Tool Resistant Safe - Class TL-15X6; (iii) Tool Resistant Safe - Class TL-30X6; (iv) Torch and Tool Resistant Safe - Class TRTL-15X6; (v) Torch and Tool Resistant Safe - Class TRTL-30X6; and (vi) Torch and Tool Resistant Safe - Class TRTL-60X6.B. Tested on Side Containing the Door; (i) Tool Resistant Safe - Class TL-15; (ii) Tool Resistant Safe - Class TL-30; (iii) Torch and Tool Resistant Safe - Class TRTL-15; and (iv) Torch and Tool Resistant Safe - Class TRTL-30.

13.310 

Burglar Resistant Combination Locks

These requirements cover combination locks designed for attachment on doors of safes, chests, vaults, and the like, to provide a means of locking the boltwork against unauthorized opening. These requirements are intended to test the ability of combination locks to resist unauthorized opening of the lock by manipulation methods such as sense or sight, touch, hearing or manipulation by electro-mechanical devices.

91.190 13.310

Burglary Resistant Key Locks

These requirements cover mechanical key locks categorized as follows: a cabinet locking cylinder; door locks; locking cylinders; security container key locks utilizing Type 1 and Type 2 locks; and two-key locks.

91.190 13.310

CAN/ULC-S329-1992Amendments 1-2

Standard For Automated Banking Machines

These requirements cover the construction and security performance of equipment intended to automatically dispense currency when operated as intended by a customer, and to provide protection against unauthorized removal of currency.

Burglary-Resistant Night Depositories

These requirements cover the construction and security performance of equipment intended to permit the deposit of cash, cheques, etc., into a security container, and to provide protection against unauthorized removal of deposits. These requirements cover (1) products intended for permanent connection to 600V or lower potential branch circuits, and (2) products intended for cord connection to 300 V or lower potential branch circuits.

13.310 

ULC-S332-1993(R1998)

Standard For Burglary Resistant Glazing Material

These requirements cover clear or translucent glazing material intended for indoor use, outdoor use, or indoor/outdoor use as a substitute for, or in combination with plate glass show window panels intended to resist burglarious attacks of the hit-and-run type.

These requirements cover the construction and security performance of equipment intended to automatically dispense currency within a financial institution when operated as intended by an authorized person, and to provide protection against unauthorized removal of currency.

03.060 13.310

Burglary Resistant Electronic Combination Locks

These requirements cover burglary resistant electronic combination locks designed for attachment on doors of safes, chests, vaults, automated bankingmachines, depository units, and the like, to provide a means of locking the boltwork against unauthorized opening.These requirements are intended to test the ability of burglary resistant electronic combination locks to resist unauthorized opening for a limited period of time. Electronic combination locks covered by these requirements may or may not have integral protection against entry by force.These requirements cover burglary resistant electronic combination locks powered by electrical circuits, or they generate their own power as a function of their operation. A power supply that is used to energize a burglary resistant electronic combination lock shall comply with the requirements of the Standard for Power Supplies for Burglar Alarm Systems, ULC-S318. If a burglary resistant electronic combination lockhas a timelock feature, it shall comply with ULC-ORD-C887, Timelocks. If a burglary resistant electronic combination lock has a time delay feature in any user mode, it shall comply with ULC-S337, Standard for Delayed-Action Timelocks.The requirements of this Standard do not apply to components and systems external to the burglary resistant electronic combination lock which are required for the administration and operation of the locking system.

91.190 13.310

These requirements cover delayed-action timelocks intended for attachment on the doors of chests, and the like, to provide a means for delaying unlocking for a predetermined length of time as protection against robbery.

Automobile Theft Deterrent Equipment and Systems: Electronic Immobilization

These requirements cover electrical or electronic immobilization systems which are installed on passenger cars and light duty trucks with 12 v electrical systems. Both OEM systems and non-OEM systems shall meet the requirements of this Standard.

13.310 43.040.99

Norme sur les systèmes et les appareillages de prévention du vol de véhicules automobiles

Ces exigences s'appliquent aux systèmes d'immobilisation électroniques ouélectriques qui sont installés dans les voitures de tourisme et les utilitaireslégers à système électrique de 12 V. Les systèmes OEM (Original Equipment Manufacturer - équipement d'originedu fabricant) et les systèmes non-OEM doivent satisfaire à cette norme.

13.310 43.040.99

Page 9: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 9 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

13.220.10 $160.00

13.220.10 $160.00

13.220.10 $160.00

13.220.10 $160.00

ULC-S505-1974 NA $110.00

13.220.10 $160.00

13.220.10 $160.00

$160.00

$160.00

CAN/ULC-S511-07 $140.00

CAN/ULC-S511-07 $140.00

CAN/ULC-S503-05 Amendment 1

Standard for Carbon-Dioxide Fire Exinguishers

This is the common UL and ULC Standard for Carbon-Dioxide Fire Extinguishers. It is the Fourth edition of CAN/ULC-S503, and the Ninth edition of ANSI/UL 154. These requirements cover the construction and performance, exclusive of performance during fire tests, of portable carbon-dioxide fire extinguishers. Carbon-dioxide fire extinguishers are intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, NFPA 10 and the National Fire Code of Canada. The requirements for performance during fire testing of carbon-dioxide fire extinguishers are specified in the Binational Standard for Rating and Fire Testing of Fire Extinguishers, ANSI/UL 711/CAN/ULC-S508.

CAN/ULC-S503-05 Modification 1

Norme sur les extincteurs au dioxyde de carbone

Ce document constitue la norme harmonisée UL et ULC, Extincteurs au dioxyde de carbone. Il s’agit de la quatrième édition de la norme CAN/ULC-S503, et de la neuvième édition de la norme ANSI/UL 154. Ces exigences visent la construction et le fonctionnement des extincteurs portatifs au dioxyde de carbone. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu. Les extincteurs au dioxyde de carbone sont destinés à être utilisés conformément à la norme NFPA 10, Standard for Portable Fire Extinguishers, et au Code national de prévention des incendies du Canada. Les exigences relatives au fonctionnement des extincteurs au dioxyde de carbone au cours des essais de réaction au feu sont spécifiées dans la norme binationale relative à la classification et essais sur foyers types des extincteurs, ANSI/UL 711/CAN/ULC-S508.

CAN/ULC-S504-02 Amendment 1

Dry Chemical Fire Extinguishers

Covers the construction and performance, exclusive of performance during fire tests, of portable dry chemical and dry powder (Class D) fire extinguishers.

CAN/ULC-S504-02 Modification 1

Extincteurs à poudres chimiques

Visent la construction et le fonctionnement des extincteurs portatifs à poudre chimique de classe D. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu.

Fusible Links for Fire Protection Services

These requirements cover fusible links used for fire-protection service. Fusible links are classified by temperature rating, type of coating or plating, minimum and maximum design load, and other factors which may have a bearing on their intended use. .

CAN/ULC-S507-05 Amendment 1

Standard for Water Fire Extinguishers

This is the common UL and ULC Standard for Water Fire Extinguishers. It is the Fourth edition of CAN/ULC-S507, and the Eighth edition of ANSI/UL 626. These requirements cover the construction and performance, exclusive of performance during fire tests, of water fire extinguishers. Water fire extinguishers are intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, NFPA 10, and the National Fire Code of Canada. These requirements cover stored-pressure, water fire extinguishers that use a single chamber for both the extinguishing agent and the expellant gas. The extinguishers covered by these requirements may be charged with plain water, an antifreeze or a loaded-stream solution. The requirements for performance during fire testing of stored-pressure water fire extinguishers are specified in the Binational Standard for Rating and Fire Testing of Fire Extinguishers, ANSI/UL 711/CAN/ULC-S508.

CAN/ULC-S507-05 Modification 1

Norme sur les extincteurs à eau

Ce document constitue la norme harmonisée UL et ULC, Extincteurs à eau. Il s’agit de la quatrième édition de la norme CAN/ULC-S507, et de la huitième édition de la norme ANSI/UL 626. Ces exigences visent la construction et le fonctionnement des extincteurs à eau. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu. Les extincteurs à eau sont destinés à être utilisés conformément à la norme NFPA 10, Standard for Portable Fire Extinguishers, et au Code national de prévention des incendies du Canada. Ces exigences couvrent les extincteurs à eau à pression permanente dont l'agent extincteur et le gaz propulseur se trouvent dans le même réservoir. Les extincteurs couverts par ces exigences peuvent être chargés d'eau ordinaire, d'antigel ou d'une solution de métal alcalin. Les exigences relatives au fonctionnement des extincteurs à eau à pression permanente au cours des essais de réaction au feu sont spécifiées dans la norme binationale relative à la classification et essais sur foyers types des extincteurs, ANSI/UL 711/CAN/ULC-S508.

CAN/ULC-S508-02Amendment 2

Standard for the Rating and Fire Testing of Fire Extinguishers

These requirements cover rating, and performance during fire tests, of fire extinguishers intended for use in attacking Class A, B, C, D, and K fires as defined herein. These requirements also cover performance during fire tests of fire extinguishing agents for application on Class D fires. The ultimate rating of an extinguisher or the prescribed use of an extinguisher or fire extinguishing agent is based on its fire-extinguishing potential as determined by fire tests and presupposes installation and use in accordance in the United States with the Standard for Portable Fire Extinguishers, NFPA 10, and with the National Fire Code of Canada.

Fire extinguishers, fire extinguishing agents, or both shall also comply with the requirements for construction and performance as applicable to specific types, designs, sizes, and arrangements. Suchadditional requirements are not within the scope of these requirements.

13.220.10 19.040

CAN/ULC-S508-02Modification 2

Classification et essai sur foyers types des extincteurs

Cette norme vise la classification et l’efficacité au cours des essais sur foyers-types des extincteurs destinés à être utilisés pour combattre les feux de classes A, B, C, D et K définis ci-dessous. Elle vise également l’efficacité au cours des essais sur foyers-types des agents extincteurs destinés à être utilisés pour combattre les feux de classe D. La classification définitive d’un extincteur ou les conditions d’utilisation d’un extincteur ou d’un agent extincteur sont basées sur leur pouvoir d’extinction déterminé au cours des essais et l’hypothèse qu’ils ont été installés et qu’ils sont utilisés conformément à la norme NFPA 10 Standard for Portable Fire Extinguishers aux États-Unis, et au Code national de prévention des incendies du Canada au Canada. Les extincteurs et (ou) les agents extincteurs doivent également satisfaire aux exigences de construction et d’efficacité pertinentes, établies en fonction du type, de la conception, des dimensions et des agencements particuliers. Toutefois, ces exigences supplémentaires ne sont pas traitées dans cette norme.

13.220.10 19.040

Standard for Lined Fire Hose for Interior Standpipes and Municipal and Industrial Fire-Protection Services

These requirements apply to single and multiple-jacketed lined fire hose of the following nominal inside diameter trade sizes: 38, 45, 50, 65, 75, 89, 100, 125, and 150 mm. These requirements do not cover couplings nor their method of attachment.

13.220.10 23.040.70

Norme sur le tuyau d'incendie entoilé pour conduites d'incendie intérieurs et services municipaux et industriels de protection incendie

Les présentes exigences s'appliquent aux tuyaux d'incendie entoilés à gaine simple et à gaines multiples dont les diamètres intérieurs nominaux commerciaux sont les suivants : 38, 45, 50, 65, 75, 89, 100, 125 et 150 mm. Les exigences ne portent pas sur les raccords ni sur leur méthode de fixation.

13.220.10 23.040.70

Page 10: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 10 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

Covers the construction and operation of halogenated agent hand-portable and wheeled type fire extinguishers. 13.220.10 $110.00

Porte sur la construction et le fonctionnement des extincteursà produits halogénés, à main et sur roues. 13.220.10 $110.00

ULC-S513-1978 $110.00

CAN/ULC-S514-07 13.220.10 $145.00

CAN/ULC-S514-07 13.220.10 $145.00

CAN/ULC-S515-04 13.220.10 $205.00

CAN/ULC-S515-04 13.220.10 $205.00

CAN/ULC-S518-M90 $110.00

$115.00

CAN/ULC-S519-M90 $110.00

$115.00

CAN/ULC-S512-M87Amendments 1-6

Standard for Halogenated Agent Hand and Wheeled Fire Extinguishers

CAN/ULC-S512-M87Modifications 1-6

Norme relative aux extincteurs à produits halogénés, à main et sur roues

Standard For Threaded Couplings For 1½- And 2½-Inch Fire Hose

This Standard covers threaded couplings for 1½‑ and 2½‑inch fire hose for use in fire protection service. 13.220.30 23.040.60

Dry Chemical for Use in Hand and Wheeled Fire Extinguishers

These requirements cover chemical, physical and performance properties of dry chemical fire extinguishing agents for use in portable fire extinguishing equipment being evaluated to CAN/ULC-S504M, Standard for Dry Chemical and Dry Powder Hand and Wheeled Fire Extinguishers.These requirements are also intended for the evaluation of recharge dry chemical fire extinguishing agents for use in extinguishers meeting the requirements of CAN/ULC-S504M, provided the performance of the combination of the extinguisher and recharge agent, including performance during fire tests, can be shown to be equivalent to that of the original extinguisher.

Norme sur les poudres chimiques utilisées dans les extincteurs, à main et sur roues

Les présentes exigences visent les propriétés chimiques, physiques et de rendement des agents extincteurs à poudres chimiques destinés aux extincteurs portatifs qui sont évalués conformément à la norme CAN/ULC‑S504, Norme sur les extincteurs à poudres chimiques. Ces exigences visent également l'évaluation de la recharge des agents extincteurs à poudres chimiques destinés aux extincteurs, conformément aux exigences de la norme CAN/ULC‑S504, à condition que le rendement de la combinaison de l'extincteur et de la recharge de l'agent extincteur, y compris pendant les essais de comportement au feu, soit équivalent à celui de l'extincteur original.

Automobile Fire Fighting Apparatus

This Standard defines the minimum performance requirements for new automobile fire fighting apparatus such as pumpers, water tank trucks, ladder trucks, aerial devices and combinations of these, as used for structural firefighting in the municipal fire service. This Standard defines the minimum requirements for the common types of fire fighting apparatus and the requirements for each of the components provided therein. This Standard does not cover optional equipment typically carried by the various types of fire fighting apparatus and the variety of combinations and functions of this equipment.

Engins automobiles de lutte contre l'incendie

La présente norme définit les exigences de rendement minimales relatives aux nouveaux engins automobiles de lutte contre l'incendie, notamment les autopompes, les camions-citernes à eau, les autos-échelles, les dispositifs aériens et des combinaisons de ces derniers, qui sont utilisés dans la lutte contre l'incendie structural au service d'incendie municipal. La présente norme définit les exigences minimales pour les types courant d'engins de lutte contre l'incendie et les exigences pour chacune des composantes prévues dans la norme. La présente norme ne porte pas sur le matériel facultatif que transportent en général les divers types d'engins de lutte contre l'incendie et la variété de combinaisons et de fonctions du matériel en question.

Standard for Non-Percolating Forestry Hose

This Standard applies to woven-jacketed, lined, non-percolating hose of the sizes commercially known as 25 mm and 38 mm, suitable for use in fighting forest fires.

13.220.20

23.040.7065.060.80ULC-S518.1-95

Amendments 1-2Standard for Synthetic Non-Percolating Forestry Hose

This Standard applies to 25 and 38 mm synthetic non-percolating type hoses having a minimum service test pressure of 2070 kPa suitable for use in fighting forest fires. These hoses are classified as follows: Class A(woven-jacketed synthetic fibre with an integral lining) and Class B (rubber-covered jacket and rubber-lined).

13.220.20 65.060.80

Standard for Percolating Forestry Hose

This Standard applies to percolating forestry hose of the size commercially known as 38 mm, suitable for use in fighting forest fires.

13.220.20

23.040.7065.060.80ULC-S519.1-95

Amendments 1-2Standard for Synthetic Percolating Forestry Hose

This Standard applies to 25 and 38 mm synthetic percolating type hoses having a minimum service test pressure of 2070 kPa suitable for use in fighting forest fires.

13.220.20

65.060.80

Page 11: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 11 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S520-07 Standard for Fire Hydrants 13.220.10 $140.00

CAN/ULC-S520-07 Poteaux d'incendie 13.220.10 $140.00

CAN/ULC-S522-07 13.220.10 $145.00

CAN/ULC-S522-07 13.220.10 $145.00

$110.00

$110.00

CAN/ULC-S524-06 $220.00

CAN/ULC-S524-06 $220.00

CAN-ULC-S525-07-EN $150.00

CAN-ULC-S525-07-FR $150.00

CAN-ULC-S526-07-EN $150.00

CAN-ULC-S526-07-FR $150.00

ULC-S527-99 $130.00

This Standard covers barrel-type hydrants with compression shut-off and slide gate shut-off, for general water works service. This Standard does not cover wet barrel type hydrants. References to the setting and drainage of hydrants are not included in this Standard.

La présente norme définit les poteaux d'incendie de type à baril avec fermeture à compression et à guillotine , pour le service général d'alimentation d'eau. La présente norme ne définit pas les poteaux d'incendie de type à baril mouillé. Des informations sur le réglage et la vidange des poteaux d'incendie ne sont pas incluses dans la présente norme.

Standard for Fire Extinguishers and Booster Hose

Covers hose in sizes of l0 mm up to and including a nominal internal diameter of 32 mm for use on portable and wheeled fire extinguishers, hand hose line fixed extinguishing systems, and also as booster hose on fire apparatus.

Norme relative aux tuyaux d’extincteur et de dévidoir tournant

S'applique aux tuyaux de diamètre intérieur nominal de 10 à 32 mminclusivement, utilisés avec les extincteurs portatifs et surroues, les systèmes d'extinction fixes à robinet armé et aussiavec les dévidoirs tournants du matériel de lutte contre les incendies.

CAN/ULC-S523-M91Amendments 1-2

Standard for Light Attack Fire Fighting Apparatus (Mini‑Pumper)

This Standard is intended to cover essential requirements for ensuring satisfactory performance of light attack apparatus for fire-fighting service. The type of apparatus covered by this Standard is intended to supplement the standard apparatus normally used by public fire departments.

13.220.30 43.160

CAN/ULC-S523-M91Modifications 1-2

Autopompes de premiere intervention de lutte contre l'incendie (mini-autopompes)

La présente norme a pour but de fournir les exigences essentielles pours'assurer que les performances des mini-autopompes des services de lutte contrel'incendie sont satisfaites. La mini-autopompe couverte par la présente norme est destinée à être uncomplément à l'autopompe standard normalement utilisée par les services publicsde lutte contre l'incendie.

13.220.30 43.160

Installation of Fire Alarm Systems

This Standard describes the requirements for the design and installation of a fire alarm system with or without voice communication capability.

13.220.20 13.320

Installation des réseaux avertisseurs d'incendie

Cette norme énonce les exigences relatives à la conception et à l'installation d'un réseau avertisseur d'incendie doté ou non d'un réseau de communication phonique.

13.220.20 13.320

Audible Signal Devices for Fire Alarm Systems, Including Accessories

These requirements cover electrically operated bells, sirens, horns, and similar audible signal devices, rated at 300 V or less, for fire-protective signalling service and intended for indoor and/or outdoor installation in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations; and with CAN/ULC‑S524, Installation of Fire Alarm Systems. Refer to CAN/ULC-S541, Speakers for Fire Alarm Systems, Including Accessories, for requirements pertaining to speakers.

This standard also covers protective covers and accessories used with audible signals for fire alarm systems.

13.220.20 13.320

Dispositifs de signalisation sonore des réseaux avertisseurs d'incendie, y compris les accessoires

Ces exigences visent les sonneries, les sirènes, les klaxons et autres dispositifs de signalisation sonore électriques d'une tension nominale égale ou inférieure à 300 V prévus pour être utilisés avec des réseaux avertisseurs d'incendie, à l'intérieur ou à l'extérieur, conformément au Code canadien de l'électricité, Première partie, Norme de sécurité relative aux installations électriques et à la norme CAN/ULC S524, Norme sur l'installation des réseaux avertisseurs d'incendie. Pour des exigences sur les haut parleurs, se reporter à la norme CAN/ULC S541, Haut parleurs pour réseaux avertisseurs d'incendie, y compris les accessoires.

La présente norme porte également sur les couvercles de protection et les accessoires utilisés avec les dispositifs de signalisation sonore des réseaux avertisseurs d'incendie.

13.220.20 13.320

Visible Signal Devices for Fire Alarm Systems, Including Accessories

This Standard covers requirements for visible signal devices for use in accordance with CAN/ULC-S524, Installation of Fire Alarm Systems, and in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations.

This standard also covers protective covers and accessories used with visible signals for fire alarm systems.

13.220.20 13.320

Dispositifs à signal visuel pour réseaux avertisseurs d'incendie, y compris les accessoires

Cette norme porte sur les exigences relatives aux dispositifs à signal visuel aux fins d'utilisation conformément à la norme CAN/ULC‑S524, Installation des réseaux avertisseurs d'incendie et au Code canadien de l'électricité, Première partie, Norme de sécurité relative aux installations électriques (CSA C22.1)

La présente norme porte également sur les couvercles de protection et les accessoires utilisés avec les dispositifs à signal visuel pour réseaux avertisseurs d'incendie.

Standard for Control Units for Fire Alarm Systems

This Standard covers requirements for control units, fire alarm systems and control unit accessories for use in accordance with the Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524, in accordance with Rule 32-004(1) of the Canadian Electrical Code, Part I, and the National Building Code of Canada. If a fire alarm system incorporates the features and functions of a proprietary system, then the requirements of ULC/ORD-C693.5, Central Station and Proprietary Fire Protective Signalling Systems Equipment, shall also apply.Transponders of distributed type systems are classified as control units and the requirements of this Standardshall apply.

These requirements apply to control units and control unit accessories for ordinary indoor locations.

These requirements do not apply to field devices unless the device is used as a component of a control unit or control unit accessory.

This Standard does not include safety requirements that are covered by the authority having jurisdiction. The requirements of this Standard apply uniformly to all equipment regardless of whether used as a component of a control unit or separately enclosed and referred to as a control unit accessory. 

13.220.20

13.320

Page 12: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 12 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC-S527-99 $130.00

CAN/ULC-S528-05 $175.00

CAN/ULC-S528-05 $175.00

CAN/ULC-S529-02 $130.00

CAN/ULC-S529-02 $130.00

CAN/ULC-S531-02 Standard for Smoke-Alarms $130.00

CAN/ULC-S531-02 $130.00

CAN/ULC-S532-07 $145.00

CAN/ULC-S532-07 $145.00

Norme Sur Les Postes De Contrôle Pour Les Réseaux Avertisseurs D'incendie

Cette norme énonce des exigences visant les postes de contrôle, les réseaux avertisseurs d'incendie et les accessoires des postes de contrôle, qui doivent être utilisés conformément à la norme CAN/ULC-S524, Installation des réseaux avertisseurs d'incendie, à l'article 32‑004 1. du Code canadien de l'électricité, Première partie et au Code national du bâtiment du Canada.Si un réseau avertisseur d'incendie comporte des caractéristiques et des fonctions d'un réseau breveté, alors la norme ULC/ORD‑C693.5, Central Station and Proprietary Fire Protective Signalisation Systems Equipement, s'applique également. Les transpondeurs de réseaux répartis sont classés dans la catégorie des postes de contrôle, et ils sont visés par cette norme.

Ces exigences s'appliquent aux postes de contrôle et aux accessoires des postes de contrôle pour les utilisations intérieures ordinaires.Ces exigences ne s'appliquent pas aux dispositifs sauf si ces derniers sont des éléments d'un poste de contrôle ou d'un accessoire de poste de contrôle.

Cette norme ne couvre pas les exigences de sécurité, qui relèvent de l'autorité compétente.Cette norme s'applique à tous les appareillages, qu’ils soient intégrés dans un poste de contrôle ou placés dans des boîtiers séparés et désignés comme des accessoires de postes de contrôle.

13.220.20

13.320

Manual Stations for Fire Alarm Systems, Including Accessories

This Standard covers manual stations and their accessories for installation in ordinary locations, indoor and outdoor, for use in fire alarm systems.

This Standard does not cover municipal fire alarm boxes or electrically actuated transmitters.

This standard also covers manual stations used for ancillary service, such as manual stations for the electrical release of extinguishing systems.

13.220.20 13.320

Avertisseurs manuels d'incendie pour les systèmes d'alarme incendie, y compris les accessoires

La présente norme porte sur les avertisseurs manuels d'incendie et leurs accessoires destinés à être installés dans des emplacements ordinaires, à l'intérieur et à l'extérieur, et à être intégrés dans des systèmes d'alarme incendie.

La présente norme ne vise pas les avertisseurs d'incendie municipaux ni les transmetteurs à commande électrique.

La présente norme s'applique également aux avertisseurs manuels d'incendie reliés au service auxiliaire, comme les avertisseurs manuels d'incendie qui servent au déclenchement électrique des systèmes d'extinction.

13.220.20 13.320

Smoke Detectors for Fire Alarm Systems

This Standard sets forth requirements for ionization-type and photoelectric-type detectors, rated at 300 V or less, to be employed in ordinary indoor locations in accordance with the following: Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524; National Building Code of Canada; and National Fire Code of Canada. This Standard covers the following types of detectors: detectors intended for open area protection, for connection to compatible control unit for operation as part of a fire alarm system; detectors intended for control of releasing devices such as electromagnetic door holders, fire dampers, etc; and duct detectors. This Standard does not cover the following: detectors for monitoring the smoke density within flues or stacks; power supplies and control units to which the detectors are intended to be connected.These are covered under the Standard for Control Units for Fire Alarm Systems - ULC-S527.

13.220.20 13.320

Détecteurs de Fumée des Réseaux Avertisseurs D'incendie

La présente norme énonce les exigences relatives aux détecteurs à ionisation ou photoélectriques, de tension nominale de 300 volts ou moins, utilisés dans des locaux intérieurs ordinaires, et qui sont conformes aux exigences énoncées dans les documents suivants : Norme sur l'installation des réseaux avertisseurs d'incendie, CAN/ULC-S524; Code national du bâtiment du Canada; Code national de prévention des incendies du Canada. La présente norme régit les types de détecteurs suivants : les détecteurs destinés à surveiller des aires ouvertes et devant être raccordés à un bloc de contrôle compatible afin de faire partie intégrante d'un réseau avertisseur d'incendie; les détecteurs destinés uniquement à commander les dispositifs de déclenchement comme les dispositifs électromagnétiques de fermeture de portes et de registres coupe-feu; et les détecteurs pour conduits. La présente norme ne régit pas les appareils suivants : les détecteurs surveillant la densité de fumée dans les conduits de fumée et les conduits de cheminée; les sources d'alimentation électrique et les blocs de commande auxquels les détecteurs sont destinés à être raccordés. Ces appareils font l'objet de la norme ULC-S527, intitulée Norme sur les postes de contrôle pour les réseaux avertisseurs d'incendie.

13.220.20 13.320

This Standard sets forth requirements for smoke-alarms, single-station and multiple-station type, rated 120 V or less, intended for open area protection in ordinary indoor locations.

A smoke-alarm, as defined by these requirements, is a self-contained unit which consists of an assembly of electrical components including a smoke chamber, alarm-sounding appliance, and provision for connection to a power supply source, either by splice leads, terminals, a cord and plug arrangement, or containing integral batteries.

13.220.20 13.320

Norme détecteurs de fumée La présente norme énonce les exigences relatives aux détecteurs de fumée simples ou interconnectés, de tension nominale de 120 volts maximum et qui sont destinés à protéger des aires ouvertes dans des locaux intérieurs ordinaires.

Dans la présente norme, l’expression « détecteur de fumée » désigne un appareil autonome constitué d’un ensemble de composants électriques, dont un compartiment sensible à la fumée et un dispositif de déclenchement d’alarme, et qui renferme des piles ou est relié à une source d’alimentation électrique au moyen de fils épissurés, de bornes de connexion ou d’un cordon de branchement muni d’une fiche.

13.220.20 13.320

Standard for the Regulation of the Servicing of Portable Fire Extinguishers

These requirements are for use in the regulation of agencies servicing portable fire extinguishers. This Standard is intended to assist in the implementation of the requirements of the National Fire Code of Canada. The Stanard for Portable Fire Extinguishers, NFPA 10, or other Standards referenced by the authority having jurisdiction.

03.080.10 13.220.10

Réglementation de l’entretien et du rechargement des extincteurs à incendie portables

Les présentes exigences sont destinées à être utilisées pour établir laréglementation des entreprises qui font l'entretien, l'essai hydrostatique etle rechargement des extincteurs à incendie portables. La présente norme a pour but d'aider à la mise en application du Codenational de prévention des incendies du Canada, de la norme NFPA 10 et desautres normes prescrites par l'autorité compétente. Les présentes exigences ne s'appliquent pas au remplissage ou chargementd'un extincteur à incendie portable avant sa vente initiale par son fabricant.

03.080.10 13.220.10

Page 13: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 13 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC-S533-02 $110.00

CAN/ULC-S536-97 $115.00

CAN/ULC-S536-97 $115.00

CAN/ULC-S536-04 $150.00

CAN/ULC-S536-04 $150.00

CAN/ULC-S537-97 $115.00

CAN/ULC-S537-97 $115.00

CAN/ULC-S537-04 $150.00

CAN/ULC-S537-04 $150.00

These requirements cover the installation of residential fire warning systems for use within dwelling units. $110.00

CAN-ULC-S541-07-EN

13.220.20; 13.320

$150.00

CAN-ULC-S541-07-FR

13.220.20; 13.320

$150.00

13.220.10 $110.00

ULC-S545-02 $130.00

ULC-S548-02 $130.00

ULC-S551-1995 $115.00

CAN/ULC-S552-02 $110.00

CAN/ULC-S552-02 $110.00

CAN/ULC-S553-02 $110.00

Standard For Egress Door Securing And Releasing Devices

This standard shall apply to egress door securing and releasing devices to perform the function of holding a door in the closed position and releasing the door to permit free egress when operated. Egress door securing and releasing devices are considered ancilliary devices and are not an integral part of the fire alarm system. This standard covers requirements for egress door securing and releasing devices for use in accordance with the Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524, and in accordance with C22.1, Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations.These requirements cover devices for use in ordinary (non-hazardous) indoor locations and locations opening to the outdoors.Devices for use in hazardous locations shall comply with the requirements of this Standard and the applicable requirements of C22.1, Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations, with respect to the location hazard. 

91.190 13.220.20

Standard for the Inspection and Testing of Fire Alarm Systems

This Standard provides requirements for the inspection and testing of fire alarm systems and specifies the devices and functions to be inspected, tested, and documented for the initial inspection and test and the periodic inspection and test.

13.220.20 13.320

19.020

Norme Sur L’inspection Et La Mise À L’essai Des Réseaux Avertisseurs D’incendie

La présente norme énonce les exigences relatives à l'inspection et à l'essai des réseaux avertisseurs d'incendie et précise les dispositifs, les fonctions et les caractéristiques qui doivent être inspectés, mis à l'essai et consignés aux fins de l'inspection et de la mise à l'essai initiales et périodiques. 

13.220.20 13.320

19.020

Inspection and Testing of Fire Alarm Systems

This Standard provides requirements for the inspection and testing of fire alarm systems and specifies the devices and functions to be inspected, tested, and documented for the periodic inspection and test.

13.220.20 13.320

19.020

Inspection Et Mise À L'essai Des Réseaux Avertisseurs D'incendie

La présente norme énonce les exigences relatives à l'inspection et à la mise à l'essai des réseaux avertisseurs d'incendie et précise les dispositifs, les fonctions et les caractéristiques qui doivent être inspectés, mis à l'essai et consignés aux fins de l'inspection et de la mise à l'essai périodiques.

13.220.20 13.320

19.020

Standard for the Verification of Fire Alarm Systems

This standard prescribes inspection and test procedures for the purpose of verifying that the fire alarm system is installed in conformance with the design and CAN/ULC-S524, Standard for the Installation of Fire Alarm Systems, and performs all of its intended functions as designed.

13.220.20 13.320

Norme Sur La Vérification Des Réseaux Avertisseurs D'incendie

Cette norme spécifie le mode opératoire d'inspection et de mise à l'essai permettant de vérifier que les réseaux avertisseurs d'incendie sont installés conformément aux exigences de la conception et à la norme CAN/ULC-S524, et que toutes les fonctions prévues de ces réseaux sont exécutées conformément à la conception. 

13.220.20 13.320

Verification of Fire Alarm Systems

This standard prescribes inspection and test procedures for the purpose of verifying that the fire alarm system is installed in conformance with the design and CAN/ULC-S524, Standard for the Installation of Fire AlarmSystems, and performs all of its intended functions as designed

13.220.20 13.320

Vérification Des Réseaux Avertisseurs D'incendie

Cette norme spécifie le mode opératoire d'inspection et de mise à l'essai permettant de vérifier que les réseaux avertisseurs d'incendie sont installés conformément aux exigences de la conception et à la norme CAN/ULC-S524 (Norme sur l'installation des réseaux avertisseurs d'incendie), et que toutes les fonctions prévues de ces réseaux sont exécutées conformément à la conception.

13.220.20 13.320

CAN/ULC-S540-M86(R1999) Standard for the Installation of Residential Fire Warning Systems

13.220.20 13.320

Speakers for Fire Alarm Systems, Including Accessories

These requirements apply to speakers, rated at 300 V or less, for fire-protective signalling service and intended for indoor and/or outdoor installation in accordance with CSA C22.1 Canadian Electrical Code, Part I, Safety Standard for Electrical Installations; and CAN/ULC S524, Installation of Fire Alarm Systems. Refer to CAN/ULC-S525, Audible Signal Devices for Fire Alarm Systems, Including Accessories, for requirements pertaining to audible signal devices.

This Standard also covers protective covers and other accessories used with speakers for fire alarm systems.

Haut parleurs pour réseaux avertisseurs d'incendie, y compris les accessoires

Ces exigences visent les haut parleurs d'une tension nominale égale ou inférieure à 300 V prévus pour être utilisés avec des réseaux avertisseurs d'incendie, à l'intérieur ou à l'extérieur, conformément au Code canadien de l'électricité, Première partie, Norme de sécurité relative aux installations électriques (CSA C22.1) et à la norme CAN/ULC S524, Installation des réseaux avertisseurs d'incendie. Pour des exigences relatives aux dispositifs de signalisation sonore, se reporter à la norme CAN/ULC S525, Dispositifs de signalisation sonore des réseaux avertisseurs d'incendie, y compris les accessoires.

La présente norme porte également sur les revêtements protecteurs et les accessoires utilisés avec les haut parleurs pour réseaux avertisseurs d'incendie.

CAN4-S543-M84 Amendments 1-2

Standard for Internal Lug Quick-Connect Coulings for Fire Hose

This Standard contains requirements for non-threaded, quick-connect couplings of the internal lug design for use in fire protection service. accommodate the attachment of couplings of the internal lug design.

Residential Fire Warning Alarm Systems Control Units

Covers requirements for residential fire warning system control units and accessories intended to be installed in accordance with the Standard for the Installation of Residential Fire Warning Systems, CAN/ULC-S540.

13.220.20 13.320

Alarm Initiating and Supervisory Devices for Water Type Extinguishing Systems

Contains requirements for Alarm Initiating and Supervisory Detection Devices for attachment to water type extinguishing systems(such as wet, dry and deluge type sprinklers, residential sprinklers, water mist suppression systems, and standpipe systems), as follows A) Alarm Initiating Devices, including but not limited to: (i) Vane and paddle type waterflow switches; and (ii) Pressure actuated waterflow switches; B) Supervisory Indicating Devices, including but not limited to: (i) Pressure supervisory switches; (ii) Shut-off valve position supervisory switches; (iii) Water level supervisory switches; and (iv) Temperature Supervisory Switches.

13.220.20 13.320

Standard For Forged External-Lug Quick-Connect Couplings And Adapters For Forestry Fire Hose

These requirements cover quick-connect couplings and adapters of the external lug design for use with forestry fire hose of the 38 mm standard size.

13.220.10 65.060.80

=Standard for Maintenance and Testing of Smoke Alarms

This Standard applies to the maintenance and testing of smoke-alarms within dwelling units as well as within sleeping rooms that are not part of dwelling units.

13.220.20 19.02

Norme sur l'entretien et la mise a l'essai des avertisseurs de fumee

Cette norme vise l’entretien et la mise à l’essai des avertisseurs de fumée dans les logements ainsi que dans les pièces où l’on dort et qui ne font pas partie des logements.

13.220.20 19.02

Standard for the Installatoin of Smoke Alarms

This Standard applies to the installation of smoke-alarms within dwelling units as well as within sleeping rooms that are not part of dwelling units.

13.220.20 13.320

Page 14: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 14 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S553-02 $110.00

13.220.10 $160.00

13.220.10 $160.00

ULC-S555-01 $110.00

ULC-S557-06 13.220.10 $130.00

ULC-S558-95 $115.00

CAN/ULC-S559-04 $150.00

CAN/ULC-S559-04 $150.00

$145.00

Norme sur l'installation des avertissuers de fumee

Cette norme vise l’installation des avertisseurs de fumée dans les logements ainsi que dans les pièces où l’on dort et qui ne font pas partie des logements.

13.220.20 13.320

CAN/ULC-S554-05 Amendment 1

Standard for Water Based Agent Fire Extinguishers

This is the common UL and ULC Standard for Water Based Agent Fire Extinguishers. It is the Second edition of CAN/ULC-S554, and the Sixth edition of ANSI/UL 8. These requirements cover the construction and performance, exclusive of performance during fire tests, of portable water based agent fire extinguishers. These fire extinguishers are intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, NFPA 10 and with the National Fire Code of Canada. The requirements for performance during fire testing of water based agent fire extinguishers are specified in the Binational Standard for Rating and Fire Testing of Fire Extinguishers, ANSI/UL 711/CAN/ULC-S508.

CAN/ULC-S554-05 Modification 1

Norme sur les extincteurs à agent à base d'eau

Ce document constitue la norme harmonisée UL et ULC, Extincteurs à agent à base d'eau. Il s’agit de la deuxième édition de la norme CAN/ULC-S554, et de la sixième édition de la norme ANSI/UL 8. Ces exigences visent la construction et le fonctionnement des extincteurs portatifs à agent à base d'eau. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu. Ces extincteurs sont destinés à être utilisés conformément à la norme NFPA 10, Standard for Portable Fire Extinguishers et au Code national de prévention des incendies du Canada. Les exigences relatives au fonctionnement des extincteurs à agent à base d'eau au cours des essais de réaction au feu sont spécifiées dans la norme binationale relative à la classification et essais sur foyers types des extincteurs, ANSI/UL 711/CAN/ULC-S508.

Standard for Fire and Emergency Service Technical Rescue Ropes and Water Rescue Throw Ropes and Associated Equipment

These requirements apply to technical rescue rope and water rescue throw rope, and associated equipmentused by rescue services. Part A covers the requirements for technical rescue rope used by emergency services for the purpose of raising, lowering or horizontally moving a maximum of two people; Part B covers the requirements for body support devices associated with technical rope, not including Class 1 body support devices; Part C covers the requirements for hardware associated with technical rescue; Part D covers the requirements for water rescue throw ropes used by rescue services for the purpose of securing or retrieving one person from water.

13.220.30 59.080.50

Standard for Back-Pack Fire Extinguishers

These requirements apply to the construction and performance of back-pack fire extinguishersfor use in fighting forest, brush, and grass fires. Back-pack extinguishers shall be classified under the following types:

Type 1 - Rigid Metal TankType 2 - Rigid Plastic TankType 3 - Soft Tank

Back-pack fire extinguishers are intended for the use with water, wetting agents, and Class A foams.

Standard for External-Lug Quick-Connect Couplings and Adapters for Forestry Fire Hose

This Standard contains requirements for 25 and 38 mm quick-connect couplings and adapters of the external lug design for use in the forestry service.

21.120.20 23.040.70

13.220.10

Equipment For Fire Signal Receiving Centres And Systems

This Standard covers requirements for fire signal receiving centre and systems which include transmitting, receiving equipment and proprietary fire signal receiving centre equipment and control unit accessories for use in accordance with the following: CAN/ULC-S524, Installation of Fire Alarm Systems; CAN/ULC-S561, Installation and Services for Fire Signal Receiving Centres and Systems; C22.1, Canadian Electrical Code, Part l, Safety Standard for Electrical Installations, and Figure 1, Typical Arrangement of Equipment for Fire Signal Receiving Centres and Systems."Where the equipment covered by the scope of this Standard incorporates the features and functions of a fire alarm system, the requirements of ULC-S527, Control Units for Fire Alarm Systems, shall also apply. CAN/ULC-S524, Installation of Fire Alarm Systems; CAN/ULC-S561, Installation and Services for Fire Signal Receiving Centres and Systems; C22.1, Canadian Electrical Code, Part l, Safety Standard for Electrical Installations, and Figure 1, Typical Arrangement of Equipment for Fire Signal Receiving Centres and Systems. Where the equipment covered by the scope of this Standard incorporates the features and functions of a fire alarm system, the requirements of ULC-S527, Control Units for Fire Alarm Systems, shall also apply.Where the equipment covered by the scope of this Standard incorporates transponders of distributed type systems, the requirements of ULC-S527, Control Units for Fire Alarm Systems, shall also apply.

13.220.20 13.320

13.310

Équipement Des Systèmes Et Des Centrales De Réception D'alarme Incendie

La présente norme porte sur les exigences relatives aux systèmes et aux centrales de réception d'alarme incendie, notamment sur le matériel de transmission et de réception et l'équipement de centrale de réception d'alarme incendie privée et les accessoires de poste de contrôle devant être utilisés conformément aux éléments suivants : CAN/ULC-S524, Installation des réseaux avertisseurs d'incendie; CAN/ULC-S561, Installation et services – systèmes et centrales de réception d'alarme incendie; C22.1, Code canadien de l'électricité, Première partie, Norme de sécurité relative aux installations électriques; Figure 1, Arrangement type de l'équipement des systèmes et des centrales de réception d'alarme incendie. Lorsque l'équipement entrant dans le domaine d'application de la présente norme incorpore les caractéristiques et les fonctionsd'un système d'alarme incendie, les exigences de la norme ULC-S527, Control Units for Fire Alarm Systems (postes de contrôle pour les réseaux avertisseurs d'incendie), s'appliquent également. Lorsque l'équipement entrant dans le domaine d'application de la présente norme incorpore des transpondeurs de systèmes répartis, les exigences de la norme ULC-S527, Control Units for Fire Alarm Systems (postes de contrôle pour les réseaux avertisseurs d'incendie), s'appliquent également.

13.220.20 13.320

13.310

CAN/ULC-S560-06 Standard for Category 3 Aqueous Film-Forming Foam (AFFF) Liquid Concentrates

The Standards for foam liquid concentrates are divided into three categories. Category 1 - Primarily for use on general-purpose hydrocarbon fires; Category 2 - Primarily for use on polar solvents, oxygenated fuels, and water-miscible fuels and all Category 1 applications; Category 3 - Primarily for use on aircraft rescue fire fighting and all Category 1 applications. This Standard refers to Category 3 Aqueous Film-Forming Foam (AFFF) Liquid Concentrates. NOTE: The requirements for Category 3 Film-Forming Fluoroprotein (FFFP) Foam Liquid Concentrates are contained in the Standard CAN/ULC-S563. The foam liquid concentrate at 1%, 3% or 6% dilution with fresh or sea water are intended primarily for use in aircraft rescue and firefighting vehicles (ARFF) but are also suitable for use in mobile, portable and fixed airfoam installations, including foam-water sprinkler systems which have been proven suitable to meet the requirements of the Standard for Categories 1 and 2 Foam Liquid Concentrates, ULC-S564, in surface extinguishment of fires involving ordinary hydrocarbon flammable liquids. These requirements do not supersede requirements prescribed in legislation or regulation by the authority having jurisdiction.

13.220.10 13.220.99

Page 15: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 15 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S560-06 $145.00

CAN/ULC-S561-03 $185.00

CAN/ULC-S561-03 $185.00

ULC-S562-06 This Standard specifies requirements and test procedures for foam chemicals used on Class "A" fuels. 13.220.10 $145.00

$145.00

$145.00

ULC-S564-06 13.220.10 $145.00

13.220.10 $160.00

Norme sur les concentrés liquides de mousse formant un film flottant extincteur (mousse AFFF), de catégorie 3

Les normes sur les concentrés liquides de mousse sont divisées en trois catégories. Catégorie 1 – Mousse destinée principalement à tous les types de feux d'hydrocarbures; Catégorie 2 – Mousse destinée principalement aux feux de solvants polaires, de combustibles oxygénés et de combustibles miscibles à l'eau, ainsi qu'à toutes les applications de la catégorie 1; Catégorie 3 - Mousse destinée principalement aux opérations de sauvetage et de lutte contre les incendies d'aéronefs, ainsi qu'à toutes les applications de la catégorie 1. Cette norme vise les concentrés liquides de mousse formant un film flottant extincteur (mousse AFFF), de catégorie 3. NOTE: Les exigences visant les concentrés liquides de mousse de fluoroprotéines formant un film extincteur (mousse FFFP), de catégorie 3, sont énoncées dans la norme CAN/ULC-S563. Les concentrés de mousse liquide dilués à 1, 3 ou 6 % avec de l'eau douce ou avec de l'eau de mer sont principalement destinés aux véhicules de sauvetage et de lutte contre les incendies d'aéronefs, mais on peut aussi les utiliser avec des dispositifs mobiles, portatifs et fixes d'extincteurs à mousse, y compris les systèmes de gicleurs mousse-eau conformes à la norme visant les concentrés liquides de mousse, des catégories 1 et 2, (ULC-S564), pour l'extinction des surface enflammées à l'occasion d'incendies d'hydrocarbures liquides inflammables ordinaires. Ces exigences ne remplacent pas celles qui sont prescrites dans la loi et les règlements par l'autorité compétente.

13.220.10 13.220.99

Installation And Services For Fire Signal Receiving Centres And Systems

This Standard covers the: A Construction, operation, installation, inspection and tests applicable to fire signal receiving centres for fire protective signalling services utilizing fire signal receiving centre facilities and satellite centres, signal processing centres and bridging centres;B Construction and operation of a proprietary fire signal receiving centre; andC Installation, inspection and tests applicable to signal transmitting units and its field device inputs at the protected premises.

This Standard does not include the test, inspection, maintenance, installation and service of the building fire alarm system at the protected premises, as required in the Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524; Standard for the Inspection and Testing of Fire Alarm Systems; CAN/ULC-S536; and the Standard for the Verification of Fire Alarm Systems, CAN/ULC-S537.

13.220.20 13.310

Installation Et Services – Systèmes Et Centrales De Réception D'alarme Incendie

La présente norme porte sur les éléments suivants : A Construction, exploitation, installation, inspection et essais applicables aux centrales de réception d'alarme incendie des services d'avertissement de protection incendie utilisant des centres de réception d'alarme incendie et des centres satellites, des centres de traitement des alarmes et des centres de transition.B Construction et exploitation d'une centrale de réception d'alarme incendie privée.C Installation, inspection et essais applicables aux postes de transmission des alarmes et aux dispositifs extérieurs sur les lieux protégés.

Le domaine d'application n'englobe pas les essais, l'inspection, la maintenance, l'installation ni les services du système d'alarme incendie de l'immeuble sur les lieux protégés, comme l'exige la norme sur l'installation des réseaux avertisseurs d'incendie (CAN/ULC-S524), la norme sur l'inspection et la mise à l'essai des réseaux avertisseurs d'incendie (CAN/ULC-S536) et la norme sur la vérification des réseaux avertisseurs d'incendie (CAN/ULC-S537).

13.220.20 13.310

Standard for Class "A" Foams

CAN/ULC-S563-06 Standard fro Category 3 Film-Forming Fluoroprotein (FFFP) Foam Liquid Concentrates

The Standards for foam liquid concentrates are divided into three categories. Category 1 - Primarily for use on general-purpose hydrocarbon fires; Category 2 - Primarily for use on polar solvents, oxygenated fuels, and water-miscible fuels and all Category 1 applications; Category 3 - Primarily for use on aircraft rescue fire fighting and all Category 1 applications. This Standard refers to Category 3 Film-Forming Fluoroprotein (FFFP) Foam Liquid Concentrates. NOTE: The requirements for Category 3 Aqueous Film-Forming Foam (AFFF) Liquid Concentrates are contained in the Standard CAN/ULC-S560. The foam liquid concentrate at 3% or 6% dilution with fresh or sea water are intended primarily for use in aircraft rescue and firefighting vehicles (ARFF) but are also suitable for use in mobile, portable and fixed airfoam installations, including foam-water sprinkler systems which have been proven suitable to meet the requirements of the Standard for Categories 1 and 2 Foam Liquid Concentrates, ULC-S564, in surface extinguishment of fires involving ordinary hydrocarbon flammable liquids. These requirements do not supersede requirements prescribed in legislation or regulation by the authority having jurisdiction.

13.220.10 71.100.99

13.220.99

CAN/ULC-S563-06 Norme sur les concentrés liquides de mousse de fluoroprotéines formant un film extincteur (mousse FFFP), de catégorie 3

Les normes sur les concentrés liquides de mousse sont divisées en trois catégories. Catégorie 1 – Mousse destinée principalement à tous les types de feux d'hydrocarbures; Catégorie 2 – Mousse destinée principalement aux feux de solvants polaires, de combustibles oxygénés et de combustibles miscibles à l'eau, ainsi qu'à toutes les applications de la catégorie 1; Catégorie 3 - Mousse destinée principalement aux opérations de sauvetage et de lutte contre les incendies d'aéronefs, ainsi qu'à toutes les applications de la catégorie 1. Cette norme vise les concentrés liquides de mousse de fluoroprotéines formant un film extincteur (mousse FFFP), de catégorie 3. NOTE: Les exigences visant les concentrés liquides de mousse formant un film flottant extincteur (mousse AFFF), de catégorie 3, sont énoncées dans la norme CAN/ULC-S560. Les concentrés de mousse liquide dilués à 3 ou 6 % avec de l'eau douce ou avec de l'eau de mer sont principalement destinés aux véhicules de sauvetage et de lutte contre les incendies d'aéronefs, mais on peut aussi les utiliser avec des dispositifs mobiles, portatifs et fixes d'extincteurs à mousse, y compris les systèmes de gicleurs mousse-eau conformes à la norme visant les concentrés liquides de mousse, des catégories 1 et 2, (ULC-S564), pour l'extinction des surface enflammées à l'occasion d'incendies d'hydrocarbures liquides inflammables ordinaires. Ces exigences ne remplacent pas celles

13.220.10 71.100.99

13.220.99

Standard for Categories 1 and 2 Foam Liquid Concentrates

The Standards for foam liquid concentrates are divided into three categories: Category 1 Category 2 Category 3. Primarily for use on general purpose on polar solvents, on aircraft rescue hydrocarbon fires oxygenated fuels, firefighting + all and water-miscible Category 1 fuels + all Category 1 applications applications This Standard refers to Categories 1 and 2 foam liquid concentrates. NOTE: The requirements for Category 3 Aqueous Film-Forming Foam (AFFF) Liquid Concentrates are contained in the Standard CAN/ULC-S560 and the requirements for Category 3 Film-Forming Fluoroprotein (FFFP) Foam Liquid Concentrates are contained inthe Standard CAN/ULC-S563.1.2 These requirements cover foam producing equipment and liquid concentrates employed for the production and discharge of foam that has an expansion ratio of 20:1 or less and is used for fire extinguishment. These requirements are based on the premise that foam equipment and specified types of foam liquid concentrates with which they are intended to be used are to be investigated for use with each other.1.3 If foam equipment covered by these requirements incorporate sprinklers, the sprinklers shall comply with the requirements for Automatic Sprinklers for Fire-Protection Service, ULC/ORD-C199.1.4 Requirements for the installation and use of foam equipment and liquid concentrates are included in the following Standards of the National Fire Protection Association: A Standard for Low Expansion Foam, NFPA 11; B Standard for the Installation of Deluge Foam-Water Sprinkler and Foam-Water Spray Systems, NFPA 16; and C Standard for the Installation of Closed-Head Foam-Water Sprinkler Systems, NFPA 16A.

CAN/ULC-S566-05 Amendment 1

Standard for Halocarbon Clean Agent Fire Extinguishers

This is the common UL and ULC Standard for Halocarbon Clean Agent Fire Extinguishers. It is the First edition of CAN/ULC-S566, and the Second edition of ANSI/UL 2129. These requirements cover the construction and performance, exclusive of performance during fire tests, of portable halocarbon clean agent fire extinguishers. Halocarbon clean agent fire extinguishers are intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, NFPA 10 and with the National Fire Code of Canada. The requirements for performance during fire testing of halocarbon clean agent fire extinguishers are specified in the Binational Standard for Rating and Fire Testing of Fire Extinguishers, ANSI/UL 711 CAN/ULC-S508.

Page 16: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 16 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

13.220.10 $160.00

$130.00

CAN/ULC-S602-07 $250.00

CAN/ULC-S602-07 $250.00

$150.00

$150.00

23.020.10 $130.00

CAN/ULC-S603.1-03 $130.00

CAN/ULC-S603.1-03 $130.00

91.060.40 $110.00

CAN/ULC-S566-05 Modification 1

Norme sur les extincteurs aux agents propres à l'halocarbure

Ce document constitue la norme harmonisée UL et ULC, Extincteurs aux agents propres à l'halocarbure. Il s’agit de la première édition de la norme CAN/ULC-S566, et de la deuxième édition de la norme ANSI/UL 2129. Ces exigences visent la construction et le fonctionnement des extincteurs portatifs aux agents propres à l'halocarbure. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu. Les extincteurs aux agents propres à l'halocarbure sont destinés à être utilisés conformément à la norme NFPA 10, Standard for Portable Fire Extinguishers et au Code national de prévention des incendies du Canada. Les exigences relatives au fonctionnement des extincteurs aux agents propres à l'halocarbure au cours des essais de réaction au feu sont spécifiées dans la norme binationale relative à la classification et essais sur foyers types des extincteurs, ANSI/UL 711/CAN/ULC-S508.

ULC-S601-00

*SEE also "TechnicalSupplements forthe Refurbishing of Underground andAboveground Tanks"

Standard for Shop Fabricated Steel Aboveground Horizontal Tanks for Flammable and Combustible Liquids

These requirements cover single and double wall cylindrical horizontal steel non-pressure tanks that are used for the aboveground storage of flammable liquids and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0. These requirements cover tanks which are fabricated, inspected and tested for leakage before shipment from the factory.These requirements do not cover tanks of capacities greater than 200 000 L.

23.020.10 75.200

Standard for Aboveground Steel Tanks for Fuel Oil and Lubricating Oil

This Standard covers the design and construction of aboveground steel non- pressure tanks intended for installation inside or outside buildings and for the storage of combustible liquid intended to be used as heating fuel and/or generator fuel and lubricating oil. It covers single wall tanks, tanks with secondary containment and double bottom tanks, having a maximum capacity of 2500 L.This Standard covers tanks fabricated, inspected and tested for leakage before shipment from the factory for use in stationary installations. These tanks are not intended for the transportation of fuel nor are they intended to be transported while containing fuel.

23.2020.10,75.160.20

Norme sur les réservoirs en acier non enterrés pour le mazout et l’huile lubrifiante

La présente norme porte sur la conception et la construction de réservoirs non pressurisés non enterrés en acier destinés à être installés à l'intérieur ou à l'extérieur de bâtiments et au stockage de liquide combustible destiné à être utilisé comme huile de chauffage ou huile pour génératrice et huile lubrifiante. La présente norme porte sur les réservoirs à paroi simple, les réservoirs à confinement secondaire et les réservoirs à double fond, dont la capacité maximale est de 2500 L.La présente norme porte sur les réservoirs fabriqués, et ayant fait l'objet d'une inspection et d'un essai pour déceler les fuites avant leur expédition de l'usine reservoirs destinés aux installations stationnaires. Ces réservoirs ne sont pas destinés au transport de combustible ou à être transportés alors qu'ils contiennent du combustible.

23.2020.10,75.160.20

CAN/ULC-S602-03 including Amendments 1 & 2

SUPERCEDED

Aboveground Steel Tanks for the Storage of Combustible Liquids Intended To Be Used as Heating and/or Generator Fuels

This Standard covers the design and construction of aboveground steel tanks of the non-pressure type, intended for installation inside or outside buildings and for the storage of combustible liquids intended to be used as heating fuel and/or generator fuel. This Standard covers single wall tanks and tanks with secondary containment, having a maximum capacity of 2500 L. This Standard covers tanks for use in stationary installations, fabricated, inspected and tested for leakage before shipment from the factory.

23.020.10 75.160.20

CAN/ULC-S602-03 incluant les modifications 1 `a 2

REMPLACER

Réservoirs En Acier Non Enterrés Destinés Au Stockage Des Liquides Combustibles Utilisés Comme Huile De Chauffage Ou Huile Pour Génératrice

La présente norme porte sur la conception et la fabrication de réservoirs en acier non enterrés et non pressurisés pouvant être installés à l'intérieur ou à l'extérieur de bâtiments et destinés au stockage de liquides combustibles utilisés comme huile de chauffage ou huile pour génératrice. Cette norme porte sur les réservoirs à paroi simple ainsi que les réservoirs à confinement secondaire, dont la capacité maximale est de 2 500 L. Cette norme porte sur les réservoirs fabriqués, et ayant fait l'objet d'une inspection et d'un essai pour déceler les fuites avant leur expédition de l'usine, et destinés aux installations stationnaires.

23.020.10 75.160.20

ULC-S603-00

*SEE also "TechnicalSupplements forthe Refurbishing of Underground andAboveground Tanks"

Standard for Steel Underground Tanks for Flammable And Combustible Liquids

This standard contains the requirements that cover single and double wall cylindrical steel tanks of the horizontal, non-pressure type that are used for the underground storage of Flammable Liquids and Combustible Liquids, such as gasoline, fuel oil, or similar products.

External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids

These requirements cover external corrosion protection systems on carbon steel underground storage tanks.These external corrosion protection systems are intended to be installed, operated and maintained in accordance with the manufacturer's instructions.These requirements cover external corrosion protection systems for steel tanks manufactured in accordance with the applicable requirements of ULC-S603, Standard for Steel Underground Tanks for Flammable and Combustible Liquids, which are used for the underground storage of flammable and combustible liquids such as gasoline, fuel oil, and similar products. In addition to meeting the construction and performance requirements contained in ULC-S603, Standard for Steel Underground Tanks for Flammable and Combustible Liquids, construction of corrosion protected steel underground tanks shall comply with the applicable requirements of this Standard. Tanks covered by these requirements are intended for installation and use in accordance with the requirements outlined in ULC-S603, Standard for Steel Underground Tanks for Flammable and Combustible Liquids and other documents.

23.020.10 75.160.20

Systèmes De Protection Contre La Corrosion Extérieure Des Réservoirs Enterrés En Acier Pour Les Liquides Inflammables Et Combustibles

Les présentes exigences portent sur les systèmes de protection contre la corrosion extérieure des réservoirs enterrés en acier au carbone. Ces systèmes de protection contre la corrosion extérieure sont destinés à être installés, mis en œuvre et entretenus conformément aux spécifications du fabricant. Ces exigences portent sur les systèmes de protection contre la corrosion extérieure pour les réservoirs en acier fabriqués conformé-ment aux exigences applicables de la norme ULC-S603, Réservoirs enterrés en acier pour les liquides inflammables et combustibles, qui sont utilisés pour le stockage souterrain des liquides inflammables et combustibles, notamment l'essence, le mazout et les produits semblables. En plus de satisfaire aux exigences relatives à la construction et au rendement contenues dans la norme ULC-S603, Réservoirs Enterrés en Acier pour les Liquides Inflammables et Combustibles, la construction des réservoirs enterrés en acier protégés contre la corrosion doit être conforme aux exigences applicables de cette norme. Les réservoirs visés par ces exigencessont destinés à une installation et une utilisation conformes aux exigences prescrites dans la norme ULC-S603, Réservoirs Enterrés en Acier pour les Liquides Inflammables et Combustibles, et dans d'autres documents.

23.020.10 75.160.20

CAN/ULC-S604-M91Amendments 1-4

Standard for Factory-Built Type A Chimneys

These requirements apply to Factory-Built Type 'A' Chimneys which do not require field fabrication. They are for use with gas and liquid fuel-fired residential appliances and building heating equipment, where the appliance or equipment flue-gas temperatures do not exceed 540 degrees C. They are intended for use in accordance with the National Building Code of Canada, Installation Code for Oil Burning Equipment, CAN/CSA-B139, and for Gas Burning Equipment,CAN/CGA-B149.1 and CAN/CGA-B149.2. They are intended for installation inside or outside of buildings to provide an essentially vertical conduit or passageway for conveying flue gases to the outer ir from the above-described class of appliances.

Page 17: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 17 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

Standard for Gas Vents 91.060.40 $110.00

$110.00

91.140.20 $110.00

91.140.20 $110.00

23.040.70 $115.00

23.040.70 $115.00

23.020.10 $130.00

23.020.10 $130.00

ULC-S618-00 $110.00

CAN/ULC-S620-99 $115.00

CAN/ULC-S620-99 Cette norme s'applique aux pistolets conçus pour contrôler le débit desliquides inflammables et combustibles. $115.00

ULC-S627-00 $130.00

CAN/ULC-S605-M91Amendments 1-4

Covers the design and construction of Type B (round or oval) and Type Bw Gas Vents. Type B Gas Vents areintended for the venting of flue gases having temperatures not exceeding 245 degrees C, from gas-firedappliances certified with draft hoods or diverters. Type BW Gas Vents are intended for the venting of flue gases from gas-fired wall furnaces and the maximum input to a Type Bw Gas Vent is determined by the maximum input of the vented wall furnace to which the type BW Vent is intended to be connected.

CAN/ULC-S609-M89Amendments 1-4

Standard for Low Temperature Vents Type L

These requirements cover the design and construction of Type L Vents which are intended for the venting of flue gases having temperatures not exceeding 300degrees C, from fuel-burning appliances certified for use with Type L Vents. They may also be used where Type B gas vents are used. They are intended for installation in buildings to provide an essentially vertical conduit or passageway for conveying flue gases to the outer air from the above described class of appliances.

91.060.40 91.140.30

CAN/ULC-S610-M87Amendments 1-6

Standard for Factory-Built Fireplaces

Part A of these requirements covers factory-built fireplaces capable of utilizing solid fuels commonly used in fireplaces and intended for provision of supplementary heating in buildings. These fireplaces are only intended for use with specified factory-built chimneys and associated parts, and are not for use with masonry chimneys. Part B of these requirements covers factory-built fireplaces capable of utilizing solid fuels commonly used in fireplaces and intended for, but not limited to, use in mobile homes. These fireplaces are only intended for use with specified factory-built chimneys and associated parts.

CAN/ULC-S610-M87Modifications1-6

Norme sur les foyers à feu ouvert préfabriqués

La partie A de ces exigences traite des foyers à feu ouvert préfabriquéspouvant utiliser des combustibles solides employés couramment dans les foyerscomme source de chaleur d'appoint dans les bâtiments. Ces foyers à feu ouvertne peuvent être raccordés qu'à des cheminées préfabriquées et leurs élémentsconnexes spécifiésREMARQUE. Ces foyers à feu ouvert ne doivent pas être raccordés à descheminées en maçonnerie. La partie B de ces exigences traite des foyers à feu ouvert préfabriquéspouvant utiliser des combustibles solides employés couramment dans les foyerset destinés, sans y être limités, aux maisons mobiles. Ces foyers ne peuventêtre raccordés qu'à des cheminées préfabriquées et leurs éléments connexesspécifiés.Les foyers à feu ouvert décrits dans cette norme doivent pouvoir êtreinstallés conformément aux instructions d'installation du fabricant, tel quel'exige la présente norme.

CAN/ULC-S612-99Amendment 1

Standard for Hose for Flammable and Combustible Liquids

This Standard sets forth requirements for hose for conducting flammable and combustible liquids handled at temperatures within the range of -40°C to +50°C, primarily into the fuel storage tank of the end use vehicle.

CAN/ULC-S612-99Modification 1

Norme Sur Les Tuyaux Flexibles Pour Liquides Inflammables et Combustibles

Cette norme énonce les exigences relatives aux tuyaux flexibles servant àacheminer des liquides inflammables et combustibles à des températurescomprises entre -40 °C et +50 °C principalement vers les réservoirs de stockagedes véhicules.

ULC-S615-98

*SEE also "TechnicalSupplements forthe Refurbishing of Underground andAboveground Tanks"

Standard for Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids

This standard contains requirements that cover reinforced plastic non-pressure tanks that are used for underground storage of flammable and combustible liquids such as gasoline, diesel fuel, oxygenated motor fuels, aviation fuel, fuel oil, and lubricating oil. These tanks may be recognized for use with other products where the tanks have been investigated for such products. These requirements cover tanks of either single or double wall construction. Tanks covered by these requirements are generally cylindrical or spherical in shape. Tanks covered by these requirements are fabricated, inspected,and tested for leakage and structural strength prior to shipment from the factory as completely assembled vessels. These requirements cover tanks where the primary tank may be single or multiple compartment. These requirements cover tanks of capacities up to, and including, 250 000 L. The requirements of this standard are for the construction of stationary tanks. The installation of these tanks may be covered by any of the following documents:A National Fire Code of Canada, Part 4;B CAN/CSA-B139, Installation Code for Oil Burning Equipment;C Environmental Code of Practice for Underground Storage Tank Systems Containing PetroleumD Regulations of the appropriate authority having jurisdiction.

ULC-S615-98

*SEE also "TechnicalSupplements forthe Refurbishing of Underground andAboveground Tanks"

Norme sur Les Reservoirs en Plastique Renforce Souterrains pour Liquides Inflammableset Combustibles

Ces exigences s'appliquent aux réservoirs en plastique renforcé non pressurisés utilisés pour le stockage souterrain de liquides inflammables et combustibles comme l'essence, le combustible diesel, les combust-ibles pour moteur oxygénés, le carburant aviation, le mazout et les lubrifiants. Ces réservoirs peuvent être utilisés pour d’autres produits s’ils ont fait l’objet d’une évaluation pertinente. Ces exigences visent lesréservoirs à simple et à double paroi. Les réservoirs visés sont généralement de forme cylindrique ou sphérique. Ces exigences visent les réservoirs fabriqués, inspectés et soumis à des essais d'étanchéité et de résistance une fois assemblés, avant leur sortie de l'usine. Ces exigences visent les réservoirs dontl’enceinte primaire présente un ou plusieurs compartiments. Ces exigences s'appliquent aux réservoirs d'une capacité maximale de 250 000 L.La norme vise la construction des réservoirs fixes. L'installationde ces réservoirs peut faire l'objet des documents suivants :A Code national de prévention des incendies du Canada, Partie 4 ;B CAN/CSA‑B139, Code d'installation des appareils de combustion au mazout ;C Code de recommandations techniques pour la protection de l’environnement applicables aux systèmes de stockage souterrains de produits pétroliers et de produits apparentés ;D Règlements des pouvoirs de réglementation compétents.

Standard for Magnesium and Zinc Anodes and Zinc and Copper/Copper Sulphate Reference Electrodes

These requirements cover buried sacrificial magnesium and zinc anode and zinc and copper/copper sulphate zinc reference electrodes which are intended for use in the cathodic protection of steel underground tanks which have been coated and installed in accordance with the requirements contained in the Standard for Galvanic Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids, CAN/ULC-S603.1.

31.080 77.120.20

77.120.60 77.140.90

Hose NozzleValves for Flammable and Combustible Liquids

These requirements cover hose nozzle valves that are intended to be used to control the flow of flammable and combustible liquids.

23.060  

Norme Sur les Pistolets pour Liquides Inflammables et Combustibles

23.060  

Standard for Space Heaters for Use with Solid Fuels

This Standard applies to hand-fuelled solid-fuel fired space heaters of the radiant, convection or forced-circulating type, intended for residential heating. This Standard applies to space heaters having provision for venting directly to the outdoors, outdoor-aired space heaters intended for installation primarily in mobile homes, and space heaters utilizing catalytic combustion elements.

27.060.10 97.100.30

Page 18: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 18 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

91.140.20 $115.00

91.060.40 $115.00

$130.00

$115.00

$115.00

ULC-S632-99 Standard for Heat Shields 91.060.40 $110.00

CAN/ULC-S633-99 $115.00

CAN/ULC-S633-99 $115.00

23.040.60 $115.00

ULC-S635-00 91.060.40 $130.00

$130.00

91.140.20 $110.00

91.140.20 $110.00

These requirements cover lining systems for new masonry chimneys. 91.060.40 $110.00

ULC-S641-00 91.060.40 $115.00

23.040.80 $110.00

ULC-S628-93Amendment 1

Standard for Fireplace Inserts

These requirements cover prefabricated inserts for masonry fireplaces designed for burning solid fuels such as wood and coal. This Standard covers catalytic combustors utilized with inserts. Any appliance which is de- signed to vent through the throat of the masonry fireplace shall be considered as being within the scope of this Standard. Installation of glass doors to existing masonry fireplaces is not covered by this Standard.

CAN/ULC-S629-M87Amendments 1-4

Standard for 650°C Factory-Built Chimneys

Covers requirements for Factory-Built Chimney assemblies which do not require field fabrication. They are for usewith gas, liquid and solid fuel-fired residential appliances and building heating equipment, where the flue-gas temperatures normally do not exceed 650 degrees C.

ULC-S630-00

*SEE also "TechnicalSupplements forthe Refurbishing of Underground andAboveground Tanks"

Shop Fabricated Steel Aboveground Vertical Tanks for Flammable and Combustible Liquids

These requirements cover single and double wall cylindrical vertical steel non-pressure tanks that are used for the aboveground storage of flammable liquids and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0.

23.020.10 75.200

ULC-S631-05 EN Standard for Isolating Bushing for Steel Undeground Tanks Protected with Ecternal Corrosion Protection Systems

Covers the requirements for low profile nylon isolating bushings with internal and external threads and component thread sealant which are intended for use in the external corrosion protection of underground steel tanks which have been installed in accordance with requirements contained in the Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids, CAN/ULC-S603.1.

29.080.20, 23.040.50

ULC-S631-05 FR Manchons isolants pour réservoirs enterres en acier protéges par des systèmes de protection contre la corrosion extérieure

Ces exigences visent les manchons isolants en nylon à bas profil à filetages intérieurs et extérieurs et à produit d’étanchéité de filets d’éléments destinés à un usage dans la protection contre la corrosion extérieure des réservoirs enterrés en acier qui ont été installés conformément aux exigences contenues dans la norme CAN/ULC‑S603.1, Systèmes de protection contre la corrosion extérieure des réservoirs enterrés en acier pour les liquides inflammables et combustibles.

29.080.20, 23.040.50

These requirements cover the construction and performance of heat shields for vertical installation between heat producing appliances, chimney connectors and combustible construction. Heat shields are intended for attachment to combustible construction for the reduction of specified minimum clearances for heat producing appliances. Heat shields are rated on a percentage basis, i.e. a 50% rated heat shield is considered suitable for the reduction of required clearances by 50%.

Flexible Underground Hose Connectors for Flammable and Combustible Liquids

This Standard sets forth requirements for flexible underground hose connectors intended for flammable and combustible liquid service at temperatures within the range of -40°C to +50°C.

23.040.60 23.040.70

Norme Sur les Raccords a Tuyaux Flexible Souterrain pour Liquids Inflammables et Combustibles

Cette norme énonce les exigences visant les raccords à tuyau flexiblesouterrain devant servir exclusivement autransfer de liquides inflammables etcombustibles à des températures comprises entre -40 °C et +50 °C.

23.040.60 23.040.70

CAN/ULC-S634-99Amendment 1

Hose Swivel Connectors for Flammable and Combustible Liquids

These requirements cover hose swivel connectors intended only for flammable and combustible liquid service excluding high aromatic or high alcohol content gasolines.

A hose swivel connector is intended for use with dispensing devices to facilitate handling of the hose nozzle valve and/or hose without subjecting the hose to twisting or torsional stress.

Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents

This Standard covers lining systems for existing masonry chimneys, which may or may not incorporate a liner of fire-clay tile, or factory-built chimneys and vents. Lining systems as covered by these requirements are notintended for use with Type BH Gas Vents, or with appliances that create positive pressures within the lining system, or cause condensation of corrosive acids.

ULC-S636-95Amendment 1

Standard for Type BH Gas Venting Systems

These requirements cover the design, construction, and performance of gas venting systems intended fornegative or positive pressure venting of gas-fired appliances producing flue gases having the following temperatures: Class I venting systems are suitable for gas-fired appliances producing flue gas temperatures of more than 135°C but not more than 245°C; and Class II venting systems are suitable for gas-fired appliances producing flue gas temperatures of 135°C or less.

27.060.20 91.140.20

91.140.30

CAN/ULC-S639-M87Modifications 1-2

Norme relative aux chimisages en acier pour foyers à feu ouvert en maçonnerie à combustibles solides

Les présentes exigences s'appliquent aux chemisages en acier préfabriqués quicomprennent un registre de tirage, un avaloir et les accessoires connexes destinés aux foyers à feu ouvert en maçonnerie. Ces chemisages constituent une construction qui peut remplacer les chemisages classiques en briques réfractaires et les registres en métal. L'installation des chemisages en acier décrits dans la présente norme doits'effectuer en suivant les exigences des codes du bâtiment qui s'appliquent etles instructions du fabricant.Remarque:Les présentes exigences ne s'appliquent pas aux foyers à feu ouvert préfabriqués, aux foyers à feu ouvert encastrables ou aux poêles.

CAN/ULC-S639-M87 Amendments 1-2

Standard for Steel Liner Assemblies for Solid-Fuel Burning Masonry Fireplaces

These requirements cover prefabricated steel liner assemblies incorporating a flue damper, smoke chamber and associated accessories for masonry fireplaces intended as an alternate form of construction to conventional fire brick liners and metal dampers. These requirements do not cover factory-built fireplaces, inserts or space heaters.

CAN/ULC-S640-M91 Amendments 1-3

Standard for Lining Systems for New Masonry Chimneys

Standard for Factory-Built Chimney Connectors and Wall Pass-Through Assemblies

These requirements apply to factory-built chimney connectors and wall pass-through assemblies that do not require field fabrication. They are for use with gas, liquid and solid-fuel-fired residential appliances and building heating equipment where the flue-gas temperatures do not normally exceed 650ºC. Factory-built chimney connectors are intended for use inside buildings to form a connection from an appliance to a factory-built chimney suitable for use with solid fuel, or to a masonry chimney.

CAN/ULC-S642-M87 (R2000)Amendment 1

Compounds and Tape for Threaded Pipe Joints

This Standard is for the determination of the acceptability of pipe joint compounds and tapes for piping systemsintended for the containment of alcohol, gasohol, natural gas and methane, oxygen, petroleum distillates, propane and butane, steam, and water (potable and non-potable). This standard also provides for the determination of the flash point and ignition temperatures, and evidence of spontaneous heating, of pipe joint compounds.

Page 19: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 19 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC-S643-00 23.020.10 $130.00

ULC-S644-00 23.040.60 $115.00

$130.00

97.040.20 $130.00

$130.00

ULC-S649-06 97.040.20 $130.00

ULC-S650-01 $130.00

ULC-S651-00 $115.00

23.020.10 $115.00

$115.00

ULC-S655-98 23.020.10 $115.00

CAN/ULC-S656-00 $130.00

Shop Fabricated Steel Aboveground Utility Tanks for Flammable and Combustible Liquids

These requirements cover single and double wall cylindrical horizontal steel non-pressure tanks that are used for the aboveground storage of flammable and combustible liquids with a relative density not greater than 1.0, such as gasoline, fuel oil, or similar products.

Emergency Breakaway Fitting for Flammable and Combustible Liquids

These requirements cover emergency breakaway fittings intended only for flammable and combustible liquid service including gasoline with up to 15% ethanol.

ULC-S645-1993Amendments 1-2

Standard For Power Roof Ventilators for Commercial and Institutional Kitchen Exhaust Systems

These ventilators are for use with exhaust systems serving restaurant type cooking equipment such as ranges, broilers, deep fat fryers, grilles, etc. They are complete units which may including a fan, motor, enclosing housing, roof penetration and duct connection flange, intended for use in exhaust systems incorporating exhaust hoods and are designed to safely remove residual exhaust vapours and airborne particles from the cooking area and discharge these exhaust products at a minimum height of 1000 mm above roof level.

97.040.20 23.120

ULC-S646-06 Standard for Exhaust Hoods and Related Controls for Commercial and Institutional Kitchens

These requirements cover exhaust hoods for commercial and institutional kitchens and are intended for placement over restaurant‑type cooking equipment, such as ranges, broilers, deep‑fat fryers, grills, etc. They may be of the shelf, canopy, island, double island or equipment mounted styles and may be known as grease extractor type, or filter type hoods. They may include provisions for the introduction of make-up air to the kitchen. They may include provisions to limit exhaust temperatures to 190°C.Exhaust hoods covered by these requirements are intended for installation in accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96. These requirements cover equipment rated not over 600 V and intended for installation under the requirements of the Canadian Electrical Code, Part I.

ULC-S647-05 Amendment 1

Standard for Exhaust Cleaning and Recirculation Assemblies for Commercial and Institutional Kitchen Exhaust Systems

This Standard applies to exhaust cleaning assemblies intended primarily for use with exhaust systems for commercial and institutional type cooking equipment such as ranges, broilers, deep fat fryers, grills, etc... that are Gas-Fuelled and Electronically-Fuelled. They are complete units typically including filter box, filters, odour removal media, fire damper, fan box, fan and motor controls and control panel. The units are located downstream from grease extractors or hood and filter assemblies and may be floor mounted, suspended in a ceiling space or roof mounted.This Standard also applies to exhaust recirculation units that are for connection to the outlet from air cleaning assemblies and are intended to temper make-up air by recycling up to 80% of the clean exhaust air to the kitchen area. The remaining make-up air is drawn from outside of the building or from areas adjoining the kitchen. The scope of this Standard does not include the evaluation of air quality when these units are used in conjunction with gas or solid fuel-fired appliances.

23.120 97.040.20

13.040.30

Standard for Grease Filters for Commercial and Insitutional Kitchen Exhaust Systems

This Standard applies to grease filters for installation in collection hoodsof commercial kitchen exhaust systems for conformance with NFPA 96requirements. Grease filters are investigated to determine their abilities to: A Remove atomized grease from the airstream; B Limit the projection of flames downstream when attacked by flame on the upstream face, after exposure to grease-laden air; C Drain off the collected grease in such a manner that it will not drip off the surface or pose a risk of fire; and D Have the structural integrity necessary for rough field handling, cleaning and maintenance

Standard for the installation and performance of ventilation and fire suppression systems for commercial and institutional cooking equipment

This Standard applies to the minimum requirements for the installation and operating performance of ventilation and fire suppression systems for commercial, industrial, institutional or similar cooking applications.

13.220.20 91.140.30

97.040.20

Emergency Valves for Flammable and Combustible Liquids

Covers emergency valves that are intended to be used for the control of flammable and combustible liquids. They are of the type used in the assembly of motor fuel dispensing equipment and associated piping systems. Valves covered by this Standard are for use with flammable and combustible liquids which are handled at temperatures within the range of -40 degrees C to +50 degrees C.

13.220 23.060

ULC-S652-93 (R2000)Amendment 1

Standard For Tank Assemblies For Collection Of Fuel Oil

These requirements cover the adaptation of tank assemblies of the non-pressure type and constructed in accordance with the basic requirements of one of the following Standards: A. ULC-S601 - Standard for Shop Fabricated Steel Aboveground Horizontal Tanks for Flammable and Combustible Liquids; B. CAN/ULC-S602 - Standard for Aboveground Steel Tanks for Fuel Oil and Lubricating Oil; C. CAN/ULC-S603 - Standard for Steel Underground Tanks for Flammable and Combustible Liquids; D. CAN/ULC-S603.1 - Standard for Galvanic Corrosion Protection Systems for Steel Underground Tanks for

ULC-S653-94Amendment 1

Standard for Aboveground Steel Contained Tank Assemblies for Flammable and Combustible Liquids

These requirements cover steel contained tank assemblies that are used for aboveground storage of flammable liquids and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0.

23.020.10 75.20

Standard for Aboveground Protected Tank Assemblies for Flammable and Combustable Liquids

These requirements cover shop fabricated aboveground protected tank assemblies that are used for the storage of flammable liquids and combustible liquids such as gasoline, fuel oil, or similar products with a specific gravity not greater than 1.0. These protected tank assemblies consist of primary tanks provided with secondary containment and protective encasement. These protected tank assemblies are intended for stationary installation and use in accordance with the following documents:A National Fire Code of Canada, Part 4;B CAN/CSA-B139, Installation Code for Oil Burning Equipment;C The Environmental Code of Practice for Aboveground Storage Tank Systems Containing Petroleum Products; andD The Requirements of the authority having jurisdiction.These requirements and tests shall not be construed as having determined suitability for use of a protected tank assembly after fire exposure, or impact by vehicles, or small arms attack.

Standard for Oil-Water Separators

These requirements cover shop fabricated single or double wall oil-water separators intended to collect and separate free oil from water to the degree as determined by the requirements herein at an inlet concentration not exceeding 2 000 mg/L. These separators shall also capture and contain oil spills under dry weather con- ditions up to the free oil containment capacity of the separator.  

13.060 23.020.99

75.180.99

Page 20: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 20 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S656-00 $130.00

CAN/ULC-S701-05 $170.00

CAN/ULC-S701-05 $170.00

CAN/ULC-S702-97 91.120.10 $130.00

CAN/ULC-S702-97 91.120.10 $130.00

ULC-S702.2-03 $130.00

$160.00

$160.00

CAN/ULC-S704-03 91.120.10 $180.00

CAN/ULC-S704-03 91.120.10 $180.00

91.120.10 $160.00

91.120.10 $160.00

Norme sur Les Separateurs Huile-Eau

Les exigences qui suivent portent sur les séparateurs huile-eau préfabriqués à paroisimple ou double servant à collecter l'huile libre de l'eau dans la mesure précisée par lesprésentes exigences, c'est-à-dire à une concentra-tion n'excédant pas 2000 mg/L dans le tuyau d'admission. Ces séparateurs doivent également pouvoir contenir les déversementsd'hydrocarbures se produisant par temps sec et capturer des quantités déversées selon lacapacité de retenue d'huile libre du séparateur.Remarque : La référence à chaque méthode d'essai exigée estindiquée dans la marge de droitepar les lettres ME suivies du numéro de l'article ou du paragraphe entre parenthèse.  

13.060 23.020.99

75.180.99

Standard for Thermal Insulation, Polystyrene, Boards and Pipe Covering

This Standard specifies the requirements for factory made rigid expanded polystyrene insulation in the form of pipe covering and boards with or without facings or coatings made by moulding (EPS) or extrusion (XPS) of expandable polystyrene beads. This Standard does not apply to laminated products manufactured with any type of rigid board facer including fibreboard, perlite board, gypsum board, or oriented strand board.

27.220 91.120.10

Norme sur l'isolant thermique en polystyrène, panneaux et revêtements de tuyauterie

Cette norme énonce des exigences visant l'isolant en polystyrène expansé rigide sous forme de panneaux et de revêtements de tuyauterie fabriqué en usine, avec ou sans surfaçage et obtenu par moulage (EPS) ou extrusion(XPS) de grains de polystyrène expansible. Cette norme ne vise pas les produits contrecollés sur lesquels est apposé un surfaçage rigide quelconque comme le carton, les panneaux de perlite, le placôplatre ou les panneaux de particules orientés.

27.220 91.120.10

Standard for Thermal Insulation Mineral Fibre for Buildings

This standard applies to mineral fibre thermal insulation manufactured in the form of faced and unfaced batts, rolls, boards and sheets. It also applies to loose fill mineral fibre thermal insulation when used in unconfined spaces with slopes not exceeding 4.5:12.

Norme sur l'isolant thermique de fibres minérales pour bâtiments

La présente norme s'applique à l'isolant thermique de fibres minéralesfabriqué sous forme de matelas, de rouleaux, de panneaux et de feuilles avec ousans surfaçage. Le surfaçage, le cas échéant, doit être soit une membraneperméable à l'air, soit une membrane pare-vapeur conformément au tableau 1 pourles types 2 et 3 respectivement. Toutefois, les matelas et les rouleaux nedoivent pas avoir un surfaçage de papier kraft. La norme vise égalementl'isolant thermique de fibres minérales en vrac lorsque ce dernier est utilisédans des espaces dissimulés dont la pente ne dépassse pas 4.5:12.

Mineral Fibre Thermal Insulation for Buildings, Part 2: Application Guidelines

These Guidelines specify the requirements for installation of mineral fibre thermal insulation products for buildings, such that a product manufactured and packaged according to CAN/ULC-S702 will provide the properties declared by the manufacturer, when installed. These Guidelines specify requirements primarily for the application of products in new construction but may be used in building retrofit or renovation applications.

91.120.10 91.100.15

CAN/ULC-S703-01Amendment 1

Standard for Cellulose Fibre Insulation (CFI) for Buildings

This Standard specifies requirements for treated wood-based cellulose fibre intended for use as thermal insulation (cellulose fibre insulation, CFI) in new and existing buildings within the temperature range of -60°C to 90°C.

91.120.10 03.120

CAN/ULC-S703-01Modification 1

Norme sur l'isolant en Fibre Cellulosique (IFC) pour les bâtiments

Cette norme énonce les exigences visant les fibres de cellulose traitées à base de bois destinées à être utilisées comme isolant thermique (isolant en fibre cellulosique ou IFC) dans les immeubles x ou existants à des températures variant entre –60 °C et 90 °C.

91.120.10 03.120

Standard for Thermal Insulation, Polyurethane and Polyisocyanurate Boards, Faced

This Standard covers requirements and test methods for closed cell polyurethane and polyisocyanurate foam thermal insulation in the form of flat rigid boards covered on both sides with a facing material and primarily intended for use in applications where the continuous use temperature is within the range -60oC to +93oC. These rigid boards are not intended to be used as structural panels. The Standard covers products made with various facing materials, which impact some physical characteristics. Products manufactured to this Standard are intended for use as thermal insulation in building construction. This Standard covers only pro-ducts in which the facing material has been bonded to the foam core in the original foam manufacturing process. This Standard does not apply to product made using fibreboard, perlite board, gypsum board, oriented strandboard, or any other rigid board, on one or both sides.

Norme sur l'isolant thermique en polyuréthane et en polyiscoyanuarate: panneaus revêtus

La présente norme porte sur les exigences et les méthodes d'essai des isolants thermiques de mousse cellulaire polyuréthane et de mousse de polyisocyanurate sous forme de panneaux plats rigides dont les deux faces sont couvertes d'un revêtement. Il s'agit de panneaux destinés principalement à être utilisés dans des endroits où la température se situe entre –60 oC et +93 oC. Ces panneaux rigides ne doivent pas servir de panneaux porteurs. La présente norme vise des produits fabriqués de différents revêtements, qui ont une incidence sur certaines propriétés physiques. Les produits fabriqués conformément à la présente norme serviront d'isolants thermiques dans la construction de bâtiments. La présente norme ne vise que les produits dont le revêtement a été collé sur le centre de la mousse au cours de la fabrication initiale de la mousse. La présente norme ne s'applique pas aux produits utilisant le panneau de fibres, le panneau de perlite, la plaque de plâtre, le panneau à copeaux orientés ou tout autre panneau rigide, sur une face ou sur les deux.

CAN/ULC-S705.1-01Amendment 2

Standard for Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium Density - Material - Specification

This Standard provides the requirements and test methods for spray-applied rigid polyurethane cellular plastics, medium density, used as a thermal insulation for both building and non-building applications, whether applied on a building site or in a prefabrication (manufacturing) facility. The material is also known as foamed in-situ insulation. The test methods used to determine the material properties provide a means of comparing different cellular plastic thermal insulations. They are intended for use in specifications, product evaluations and quality control. They are not intended to predict end-use product performance. The testing and evaluation of a product against this Standard may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this Standard has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any existing applicable regulatory requirements prior to its use.

CAN/ULC-S705.1-01Modification 2

Norme sur l`isolant thermique en mousse de polyuréthane rigide pulvérisée, de densité moyenne :spécifications relatives aux matériaux

Cette norme énonce les exigences et les méthodes d'essai relatives à l'isolant thermique en plastique alvéolaire rigide de polyuréthane pulvérisé, de densité moyenne, utilisé dans le secteur du bâtiment et dans des secteurs autres que celui du bâtiment, que ce soit sur le chantier ou dans une usine de préfabrication. On appelle également ce matériau isolant poreux coulé sur place. Les méthodes d'essai utilisées pour établir les propriétés des matériaux permettent de comparer divers isolants thermiques en plastique alvéolaire. Ces méthodes doivent être utilisées dans les spécifications, les évaluations de produit et le contrôle de la qualité. Elles ne visent pas à prédire le rendement du produit fini. La mise à l'essai et l'évaluation d'un produit selon cette norme peuvent nécessiter l'emploi de matériaux ou d'appareils susceptibles d'être dangereux. Ce document n'entend pas traiter de tous les aspects liés à la sécurité de son utilisation. Il appartient à l'utilisateur de la norme de se renseigner auprès des autorités compétentes et d'adopter des pratiques d'hygiène et de sécurité conformes aux règlements en vigueur avant de l'utiliser.

Page 21: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 21 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S705.2-05 $150.00

CAN/ULC-S705.2-05 $150.00

79.060.20 $130.00

CAN/ULC-S706-02 79.060.20 $130.00

CAN/ULC-S710.1-05 $170.00

CAN/ULC-S710.1-05 $170.00

CAN/ULC-S710.2-05 $170.00

CAN/ULC-S710.2-05 $170.00

Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Application

This Standard outlines requirements for the installation of spray applied rigid polyurethane foam, medium density. The material can be installed as thermal insulation, air barrier, vapour barrier or any combination of these three applications. The application requirements are for the installation of spray applied rigid polyurethane cellular plastic whether applied on a building site or in a prefabrication (manufacturing) facility. This Standard may be used for non-building applications when agreed to by the supplier and the purchaser. These requirements include obligations for the manufacturer (or supplier), the contractor and the installer. These requirements include the selection of chemical components, application requirements, quality control and documentation of the application, limitations for the application and requirements for safety and for disposal of associated waste material and packaging. Spray application of spray polyurethane foam, medium density according to this Standard requires the use of materials and/or equipment that could be hazardous. Anyone using this Standard has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any existing applicable regulatory requirements prior to its use.

91.120.10 03.120

Norme sur l'isolant thermique en mousse de polyuréthane rigide pulvérisée, de densité moyenne – Application

La présente norme indique les exigences relatives à l'installation de mousse de polyuréthane rigide pulvérisée, de densité moyenne. Ce matériau peut être installé comme isolant thermique, pare-vent, pare-vapeur ou toute combinaison de ces trois applications. Les exigences en matière d'application visent l'installation de plastique alvéolaire de polyuréthane rigide pulvérisé, qu'il soit appliqué dans un chantier de construction ou dans une usine de préfabrication. Le fournisseur et l'acheteur peuvent convenir d'utiliser la présente norme dans le cas d'applications non liées à la construction. Ces exigences comportent des obligations pour le fabricant (ou le fournisseur), l'entrepreneur et l'installateur. Ces exigences comprennent le choix des composants chimiques, les exigences en matière d'application, le contrôle de la qualité et la documentation de l'application, les restrictions relatives à l'application et les exigences en matières de sécurité et d'élimination des matières-déchets et des emballages s'y rattachant. La pulvérisation de mousse de polyuréthane rigide de densité moyenne conformément à cette norme exige l'utilisation de matériaux et de matériel qui pourraient être dangereux. Toute personne utilisant la présente norme a la responsabilité de consulter les autorités compétentes et d'établir, avant son utilisation, des pratiques de santé et de sécurité appropriées tenant compte des exigences réglementaires applicables déjà existantes.

91.120.10 03.120

CAN/ULC-S706-02 (Supersedes CAN/CSA-A247-M86)

Standard for Wood Fibre Thermal Insulation for Buildings

This Standard contains requirements and test methods for wood fibre thermal insulation manufactured in the form of faced or unfaced panels . The Standard covers four types of wood fibre insulation on the basis of their material properties. (a) Type I - Preformed insulation in the form of boards, sheets, or panels without a facer or coating (b) Type II - Preformed insulation in the form of boards, sheets, or panels with a facer or coating. (c) Type III - Preformed insulation in the form of boards, sheets, or panels with a facer or coating with air leakage properties of 0,02 L/(s·m2) or less. (d) Type IV - Preformed insulation in the form of boards, sheets, or panels with a facer or coating with water vapour permeance of 45 Ng/(Pa·s·m2) or less.

Norme sur l’isolant thermique en fibre de bois pour bâtiments

Cette norme décrit les exigences et les méthodes d'essais visant l'isolant thermique en fibre de bois en panneaux revêtus ou non. La norme vise quatre types d'isolant en fibre de bois définis suivant les caractéristiques du matériau constitutif.

a) Type I - Matériau isolant préformé en planches, feuilles ou panneaux non revetus.b) Type II - Matériau isolant préformé en planches, feuilles ou panneaux revêtus.c) Type III - Matériau isolant préformé en planches, feuilles ou panneaux revêtus laissant passer l'air à raison de 0.02 L/(s•m²) ou moins.d) Type IV - Matériau isolant préformé en planches, feuilles ou panneaux revêtus ayant une permeance à la vapeur d'eau de 45 ng/(Pa•s•m²) ou moins.

Standard for Thermal Insulation - Bead - Applied One Component Polyurethane Air Sealant Foam, Part 1: Material Specification

This Standard specifies the requirements and test methods for bead-applied one component polyurethane foam used as an insulating air sealant for both building and non-building applications. This Standard covers bead-applied one-component polyurethane air sealant foam whether applied on a building site or in a prefabrication (manufacturing) process. The one-component polyurethane foam is factory pre-packaged. Bead-applied one component polyurethane foam shall not be used when the continuous service temperature is outside the range of –60 to +110ºC. One component polyurethane air sealant foam shall be installed in accordance with the manufacturer’s instructions and CAN/ULC S710.2, Standard for Thermal Insulation – Bead-Applied One Component Polyurethane Air Sealant Foam - Part 2: Installation.

91.100.50, 91.120.10

Norme sur l’isolant thermique – mousse d’étanchéité à l’air de polyuréthane monocomposant appliquée en cordon, partie 1 : spécifications relatives au matériau

La présente norme spécifie les exigences et les méthodes d'essai pour la mousse de polyuréthane monocomposant appliquée en cordon utilisée comme isolant étanche à l’air dans les secteurs du bâtiment et autres que celui du bâtiment. La présente norme couvre la mousse d'étanchéité à l'air de polyuréthane monocomposant appliquée en cordon, formée in situ ou lors du processus de préfabrication (en usine). La mousse de polyuréthane monocomposant est préemballée en usine.La mousse de polyuréthane monocomposant appliquée en cordon ne doit pas être utilisée dans les endroits où la température de service continu ne se situe pas entre -60 et +110 ºC. La mousse d'étanchéité à l'air de polyuréthane monocomposant doit être installée conformément aux directives du fabricant et à la norme CAN/ULC S710.2, Norme sur l'isolant thermique – mousse d'étanchéité à l'air de polyuréthane monocomposant appliquée en cordon - Partie 2 : Installation.

91.100.50, 91.120.10

Standard for Thermal Insulation – Bead-Applied One Component Polyurethane Air Sealant Foam – Part 2: Installation

This Standard outlines requirements for the installation of bead-applied one component polyurethane foam used as an insulating air sealant for both building and non-building applications. The material is installed as air sealant foam in holes, cracks or gaps in buildings or in a prefabrication (manufacturing) process. The one-component polyurethane foam is factory pre-packaged. These are requirements for the manufacturer and the installer. Bead-applied one component polyurethane foam shall not be used when the continuous service temperature is outside the range of –60 to +110ºC. These requirements include the proper selection of the air sealant foam, installation requirements, limitations for the installation and recommendations for safety and for disposal of associated waste material and packaging.

91.100.50, 91.120.10

Norme sur l'isolant technique – mousse d'étanchéité à l'air de polyuréthane monocomposant appliquée en cordon, partie 2 : Installation

La présente norme spécifie les exigences relatives à l'installation de mousse de polyuréthane monocomposant ppliquée en cordon utilisée comme isolant étanche à l'air dans les secteurs du bâtiment et autres que celui du bâtiment. Le matériau est installé comme mousse d'étanchéité à l'air pour combler les trous, les fissures ou les espaces de joint, dans la construction d'édifices ou lors du processus de préfabrication (en usine). La mousse d'étanchéité de polyuréthane monocomposant est préemballée en usine. Les présentes exigences s'adressent à la fois au fabricant et à l'installateur. La mousse de polyuréthane monocomposant appliquée en cordon ne doit pas être utilisée dans les endroits où la température de service continu ne se situe pas entre -60 et +110 ºC. Les présentes exigences comprennent des indications permettant de choisir la mousse d'étanchéité à l'air appropriée, des exigences et des restrictions d'installation, des recommandations en matière de sécurité et d'élimination des déchets connexes et les exigences d'emballage.

91.100.50, 91.120.10

Page 22: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 22 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S711.1-05 $170.00

CAN/ULC-S711.1-05 $170.00

CAN/ULC-S711.2-05 $170.00

CAN/ULC-S711.2-05 $170.00

CAN/ULC-S770-03 $130.00

CAN/ULC-S770-03 $130.00

ULC-S771-01 Template for Thermal Insulation Material Standards $110.00

ULC-S772 Template for Thermal Insulation Application Guidelines $110.00

CAN/ULC-S773-01 $115.00

CAN/ULC-S773-01 $115.00

Standard for Thermal Insulation - Bead-Applied Two Component Polyurethane Air Sealant Foam Part 1: Material Specification

This Standard specifies the requirements and test methods for thermal insulating bead - applied two-component polyurethane foam used as an insulating air sealant for both building and non-building applications. This Standard covers bead-applied two-component polyurethane air sealant foam whether applied on a building site or in a prefabrication (manufacturing) process. This two-component polyurethane air sealant foam is factorypre-packaged.Bead-applied two component polyurethane foam shall not be used when the continuous servicetemperature is outside the range of -60 to +110ºC. The test methods used to determine the material propertiesprovide a means of comparing different polyurethane air sealant foams. They are intended for use in specifications, product evaluations and quality control. Bead-applied two component polyurethane air sealant foam shall be installed in accordance with the manufacturer’s instructions and CAN/ULC S711.2 Thermal Insulation –Bead-Applied Two Component Polyurethane Air Sealant Foam – Part 2: Installation.

91.100.50, 91.120.10

Norme sur l’isolation technique – norme sur l'isolant thermique – mousse d’étanchéité à l’air de polyuréthane bicomposant appliquée en cordon, partie 1 : spécifications relatives au matériau

La présente norme spécifie les exigences et les méthodes d'essai pour la mousse de polyuréthane bicomposant appliquée en cordon utilisée comme isolant étanche à l’air dans les secteurs du bâtiment et autres que celui du bâtiment. La présente norme couvre la mousse d'étanchéité à l'air de polyuréthane bicomposant appliquée en cordon, formée in situ ou lors du processus de préfabrication (en usine). La mousse de polyuréthane d'étanchéité à l’air bicomposant est préemballée en usine. La mousse de polyuréthane bicomposant appliquée en cordon ne doit pas être utilisée dans les endroits où la température de service continu ne se situe pas entre -60 et +110 ºC. Les méthodes d’essai utilisées pour établir les propriétés des matériaux permettent de comparer les diverses mousses d’étanchéité à l'air de polyuréthane. Elles doivent être utilisées dans les spécifications, les évaluations des produits et les systèmes de contrôle de la qualité. La mousse d'étanchéité à l'air de polyuréthane bicomposant appliquée en cordon doit être installée conformément aux instructions du fabricant et à la norme CAN/ULC S711.2, Norme sur l'isolant thermique – mousse d'étanchéité à l'air de polyuréthane bicomposant appliquée en cordon - Partie 2 : Installation.

91.100.50, 91.120.10

Standard for Thermal Insulation – Bead-Applied Two Component Polyurethane Air Sealant Foam – Part 2: Installation

This Standard specifies the requirements for the installation of thermal insulating bead-applied two-component polyurethane foam used as an insulating air sealant (including a component within an air barrier system) for both building and non-building applications. The material is installed as air sealant foam in holes, cracks or gaps. These are requirements for both the manufacturer and the installer. Bead-applied two component polyurethane foam shall not be used when the continuous service temperature is outside the range of -60 to +110ºC. These requirements include the proper selection of the air sealant foam, installation requirements, imitations for the installation, testing, recommendations for safety and recommendations for disposal of associated waste material and packaging.

91.100.50, 91.120.10

Norme sur l'isolation technique - mousse d'étanchéité à l'air de polyuréthane bicomposant appliquée en cordon - partie 2 : installation

La présente norme spécifie les exigences relatives à l'installation de mousse de polyuréthane bicomposant appliquée en cordon utilisée comme isolant étanche à l'air (y compris un composant dans un système de pare-air) dans les secteurs du bâtiment et autres que celui du bâtiment. Le matériau est installé comme mousse d'étanchéité à l'air pour combler les trous, les fissures ou les espaces de joint. Les présentes exigences s'adressent à la fois au fabricant et à l'installateur. La mousse de polyuréthane bicomposant appliquée en cordon ne doit pas être utilisée dans les endroits où la température de service continu ne se situe pas entre -60 et +110 ºC. Les présentes exigences comprennent des indications permettant de choisir la mousse d'étanchéité à l'air appropriée, des exigences et des restrictions d'installations, les exigences relatives aux essais, des recommandations en matière de sécurité et d'élimination des déchets connexes et les exigences d'emballage.

91.100.50, 91.120.10

Standard Test Method for Determination of Long-term Thermal Resistance of Closed-Cell Thermal Insulating Foams

This procedure defines the long-term thermal resistance (LTTR) of a foam product as the value measured after 5-year storage in a laboratory environment and provides means for its prediction based on an accelerated laboratory test. This procedure, based on ASTM standard test methods C 1303 and C 518, can be applied to a wide range of preformed as well as field applied insulating foams. This procedure estimates the change in the thermal resistivity of insulating foam products by means of slicing and scaling. This test procedure is applicable to cellular plastic insulation manufactured with the intent to retain a blowing agent, other than air, for a period longer than 180 days. This procedure specifies reference time, sampling and testing requirements for the application of ASTM standard test method C 1303 to determine LTTR for closed-cell foams such as extruded polystyrene, sprayed polyurethane, and polyisocyanurate.

91.100.60 91.120.10

Méthode dèssai normalisée pour la détermination de la résistance thermique à long terme des mousses islolantes cellulaires

Selon cette méthode, la résistance thermique à long terme (RTLT) d'une mousse isolante est la valeur mesurée après une période d'entreposage en laboratoire de 5 ans, et elle permet de prévoir la RTLT d'après un essai de vieillissement accéléré en laboratoire. On peut utiliser cette méthode, basée sur les méthodes d'essai normalisées ASTM C 1303 et C 518, avec une vaste gamme de produits de mousse isolante préformés ou appliqués sur place. Elle permet d'évaluer le changement de résistivité thermique de ces produits par des méthodes de découpage et de proportionnalité. On peut également l'utiliser avec des plastiques alvéolaires qui sont conçus pour retenir un agent gonflant, autre que l'air, pendant plus de 180 jours. Cette méthode précise les exigences relatives à la période de référence, à l'échantillonnage et aux essais pour l'application de la méthode d'essai normalisée ASTM C 1303 afin de déterminer la RTLT de mousses cellulaires comme le polystyrène extrudé, le polyuréthane pulvérisé et le polyisocyanurate.

91.100.60 91.120.10

Template for Thermal Insulation Material Standards

01.140.01 91.120.10

Template for Thermal Insulation Application Guidelines

01.140.01 91.120.10

Standard for Thermal Insulation Terminology

The main intent of this document is to provide accurate and consistent terms used in the Canadian Thermal Insulation industry. More specifically, the application of the information contained in this Standard is for reference use with the Thermal insulation series of Standards, ULC-S700.

01.140.01 91.120.10

Norme sur la terminologie de l'isolation thermique

Le but premier de cette norme est de définir les termes les plus couramment utilisés dans l'industrie de l'isolation thermique au Canada de façon à en uniformiser l'emploi. Ainsi, les renseignements contenus dans cette norme s'appliquent à la série de normes ULC-S700.

01.140.01 91.120.10

Page 23: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 23 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

CAN/ULC-S774-03 $180.00

CAN/ULC-S774-03 $180.00

$140.00

$140.00

$210.00

$210.00

$130.00

$130.00

$130.00

$130.00

Standard Laboratory Guide for the Determination of Volatile Organic Compound Emissions from Polyurethane Foam

This laboratory guide has been developed for the assessment of volatile organic compound emissions from polyurethane foam. It outlines a test procedure for the determination of volatile organic compounds from the foam and explains why certain test conditions have been selected. Upon agreement between the purchaser and the manufacturer, this test method may be used for other materials such as thermal insulation products. This laboratory guide specifies recommended procedures for the use of test chambers to evaluate emissions from the insulation product at a point in time following its installation. This laboratory guide is based on ASTM D 5116, which describes a procedure using small-scale environmental chambers to determine volatile organic compound emissions from a variety of materials. The chamber methodology only presents a simple picture of the complex nature and interactions of emissions that may exist in home and work environments. Therefore, the results from these tests cannot fully represent “real life” conditions and they will err on the side of conservatism. However, data from the chamber procedure is useful for identifying potential sources of chemicals that may adversely affect the health of the occupants.

19.040 91.120.10

Guide standard de composés organiques volatils de laboratoire pour l`évaluation des émissions de la mousee de polyuréthane

Le présent guide de laboratoire a été élaboré aux fins de l’évaluation des émissions de composés organiques volatils de la mousse de polyuréthane. On y trouve la méthode d'essai utilisée pour évaluer les composés organiques volatils qui se dégagent de la mousse, ainsi que des explications concernant le choix de certaines conditions d’essais. Par accord entre l’acheteur et le fabricant, cette méthode d’essai peut servir dans le cas d’autres matériaux tels que les produits isolants thermiques. On y énonce des méthodes recommandées pour l’utilisation de caissons d’essai dans le but d’évaluer les émissions s’échappant du produit isolant à un moment donné après son installation. Le présent guide de laboratoire est basé sur la norme ASTM D 5116, décrivant une méthode selon laquelle on utilise des petits caissons climatiques pour déterminer les émissions de composés organiques volatils provenant d’une variété de matériaux. Une telle méthodologie ne présente qu’untableau simplifié de la nature complexe et des interactions des émissions qui peuvent exister à domicile ou au travail. Par conséquent, les résultats de ces essais ne peuvent représenter fidèlement les conditions réelles et il convient alors d'adopter une ligne conservatrice. Les données recueillies des essais effectués dans un caisson climatique sont toutefois utiles pour identifier les sources potentielles de produits chimiques qui pourraient nuire à la santé des occupants.

19.040 91.120.10

CAN/ULC-60743-04Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live Working - Terminology for Tools, Equipment and Devices

This international standard applies to the terminology used to describe tools, equipment, devices and methods used in live working. IEC 60500 (651) gives the definitions of all terms used in live working. The present standard permits identification of the tools, equipment and devices and standardizes their names.

29.240.20, 29.260.99,

29.260

CAN/ULC-60743-04Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux sous Tension – Terminologie pour L’outillage, le Material et les Dispositifs

La présente Norme internationale s’applique à la terminologie utilisée pour décrire les outils, le matériel, les dispositifs et les méthodes utilisée dans les travaux sous tension. La CEI 60050 (651) contient les définitions de tous les termes utilisés pour les travaux sous tension. La présente norme permet l’identification des outils, du matériel et des dispositifs, et normalise leurs noms.

29.240.20, 29.260.99,

29.260

CAN/ULC-D60832-99Amendment 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Insulating poles (Insulating Sticks) and Universal Tool Attachments (Fitting) for Live Working

This National Standard of Canada is equivalent to International Standard CEI/IEC 60832: 1988. This Standard is applicable to insulating poles (insulating sticks) and tool attachments (fittings).

13.260 29.240.20

29.260.99

CAN/ULC-D60832-99Modification 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Perches isolantes et Outils Adaptables pour Travaux sous Tension

La présente Norme nationale du Canada est équivalente à la Norme internationaleCEI/IEC 60832: 1988.Cette norme est applicable aux perches isolantes etaux outils adaptables.

13.260 29.240.20

29.260.99

CAN/ULC-D60855-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live working -- Insulating Foam-Filled Tubes and Solid Rods for Live Working

This Standard is applicable to insulating foam-filled tubes and solid rods made of synthetic materials and intended for tools and equipment for live work on systems operating at voltages above 1 kV.

13.260 29.240.20

29.260.99

CAN/ULC-D60855-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux sous tension -- Tubes Isolants Remplis de Mousse et Tiges Isolantes Pleines Pour Travaux sous Tension

La présente norme est applicable aux tubes isolants remplis de mousse et auxtiges isolantes pleines fabriqués en matériaux synthétiques et destinés auxoutils et matériels pour travaux sous tension utilisés sur des réseaux detension nominale supérieure à 1 kV.

13.260 29.240.20

29.260.99

CAN/ULC-60895-04Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live Working – Conductive Clothing For Use at Nominal Voltage Up to 800 kV A.C. and ±600 kV D.C.

This International Standard is applicable to conductive clothing, either assembled from component parts or forming a single complete clothing, worn by (electrically) skilled persons during live working (especially bare-hand working) at a nominal power system voltage up to 800 kV a.c. and ±600 kV d.c. It is applicable to conductive jackets, trousers, coveralls (one-piece clothing), gloves or mitts, hoods, shoes, overshoe socks and socks.

13.260, 29.240, 29.260.99

CAN/ULC-60895-04Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux xous Tension – Vetements Conducteurs pour Usage Jusqu’a 800 kV de Tension Nominale en Courant Alternatif et ±600 kV en Courant Continu

La présente Norme internationale est applicable aux vêtements conducteurs, qu’ils soient constitués de plusieurs éléments ou d’une seule pièce, portés par des personnes (électriquement) qualifiées lorsqu'elles travaillent sous tension (en particulier lors du travail au potentiel) pour des tensions nominales allant jusqu'à 800 kV en courant alternatif et à ±600 kV en courant continu. Elle est applicable aux vestons, pantalons, combinaisons (d’une seule pièce), aux gants ou moufles, aux cagoules, aux chaussures, aux couvre-chaussures (chausses) et aux chaussettes conducteurs.

13.260, 29.240, 29.260.99

Page 24: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 24 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$240.00

$240.00

$200.00

$200.00

$170.00

$170.00

$170.00

$170.00

$185.00

$185.00

$160.00

CAN/ULC-D60900-99Amendment 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Hand Tools for Live Working up to 1000 V a.c. and 1500 V d.c.

This National Standard of Canada is equivalent to International Standard CEI/IEC 60900: 1987. This standard is applicable to insulated and insulating hand tools used for working live or close to live parts at nominal voltages up to 1 000 V a.c. and1 500 V d.c. Not included are tools and equipment and material supplied from an external energy source, insulating rods and poles, used for working at a distance, which are covered by IEC 855.

13.260 29.240

29.260.99

CAN/ULC-D60900-99Modification 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Outils à Main Pour Travaux Sous Tension Jusqu'à 1 000 V en Courant Alternatif et 1 500 V en Courant Continu

La présente Norme nationale du Canada est équivalente à la Norme internationaleCEI/IEC 60900: 1987.1 La présente norme est applicable aux outils à main isolés et isolants utiliséssous tension ou à proximité d'installations sous tension, de tension nominalejusqu'à 1000 V en courant alternatif et 1 500 V en courant continu.Elle n'est pas applicable : - aux outils et aux appareils alimentés par une source extérieure ; - aux perches et tiges isolantes utilisées pour le travail à distance, qui répondent à la CEI 855.

13.260 29.240

29.260.99

CAN/ULC-60903-04Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live Working – Gloves of Insulating Material

This International Standard is applicable to: – insulating gloves and mitts which should normally be used in conjunction with leather protector gloves worn over the insulating gloves to provide mechanical protection; –insulating gloves and mitts usable without over-gloves for mechanical protection. Unless otherwise stated, the use of the term “glove” includes both gloves and mitts. The use of the term “insulating gloves” designates gloves providing electrical protection only. The use of the term “composite gloves” designates gloves providingelectrical and mechanical protection.

13.260, 29.240, 29.260.99

CAN/ULC-60903-04Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux Sous Tension – Gants en Materiau Isolant

La présente Norme internationale est applicable: - aux gants et moufles isolants, qu’il convient normalement d’utiliser avec un surgant de cuir qui donne la protection mécanique; – aux gants et moufles isolants utilisés sans surgants protecteurs. Sauf indication contraire, l’utilisation du seul terme «gant» comprend gant et moufle.Le terme «gants isolants» désigne les gants qui fournissent uniquement une protection électrique. Le terme «gants composites» désigne les gants fournissant une protection mécanique et électrique.

13.260, 29.240, 29.260.99

CAN/ULC-D60984-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Sleeves of Insulating Material for Live Working

This standard is applicable to insulating sleeves for the protection of workers from accidental contact with live electrical conductors, apparatus or circuits.

13.260 29.260.99

CAN/ULC-D60984-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Protège-Bras en Matériaux Isolants Pour Travaux Electriques

Cette norme concerne les protège-bras isolants destinés àprotéger les travailleurs contre les contacts accidentels avec des conducteurs,des appareils ou des circuits sous tension.

13.260 29.260.99

CAN/ULC-D61112-01Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Blankets of Insulating Material for Electrical Purposes

This National Standard of Canada is based on International Standard CEI/IEC 61112: 1992 (first edition, 1992-12) including Corrigendum (dated May 2000).This Standard is applicable to insulating blankets for the protection of workers from accidental contact with live or earthed electrical conductors, apparatus or circuits and avoidance of short circuits on a.c. and d.c. installations.ClassesFive classes of blankets, differing in electrical characteristics, are provided and designated as class 0, class 1, class 2, class 3, and class 4.CategoriesSix categories of blankets different in properties related to acid, oil, ozone, mechanical puncture and a combination of oil and ozone are provided and designated categories A, H, Z, M, S respectively, and also extreme low temperature designated category C.

13.260 29.240.20

29.260.99

CAN/ULC-D61112-01Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Nappes en Matériau Isolant Pour Travaux Electriques

La présente Norme nationale du Canada est basée sur la Norme internationale CEI/IEC 61112: 1992 (première édition, 1992-12) avec Corrigendum (portant les mentions Mai 2000).La présente norme est applicable aux nappes isolantes pour la protection ds travailleurs contre un contact accidental avec des conducteurs électriques sous tension ou mis à la terre, des appareils ou des circuits, et contre les courts-circuits dans des installations à courant alternatif ou continue.ClassesCinq classes de nappes, de caractéritiques électriques différentes, sont prévues et ont deéignées comme suit: classe 0, classe 1, classe 2, classe 3, et classe 4.CatégoriesSix catégories de nappes de propriétés différentes par rapport à l'acid, à l'huile, à l'ozone, à la perforation mécanique, et à une combinaison de l'huile et de l'ozone sont fournies et désignées respectivement par les lettres A, H, Z, M, S; et aussi pour celles résistant aux très basses températures, par la lettre C.

13.260 29.240.20

29.260.99

CAN/ULC-D61229-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Rigid Protective Covers for Live Working on a.c. Installations

This standard is applicable to rigid insulating covers for live working on a.c. installations, including those described in IEC 743.

13.260 29.260.99

CAN/ULC-D61229-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Protecteurs Rigides pour Travaux Sous Tension sur Des Installations à Courant Alternatif

Cette Norme s'applique aux protecteurs rigides pourtravaux sous tension, en courant alternatif, incluant ceux qui sont décritsdans la CEI 743.

13.260 29.260.99

CAN/ULC-D61230-99 Amendment 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live working -- Portable Equipment for Grounding and Bonding

This National Standard of Canada is equivalent to International Standard CEI/IEC 61230: 1993. This Standard is applicable to portable equipment, with or without matching fixed connection points, for temporary earthing or earthing and short-circuiting of electrically isolated a.c. transmission and distribution systems, including railway systems, for the protection of workers.

13.260 29.240.20

29.260.99

Page 25: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 25 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$160.00

$130.00

$130.00

$160.00

$160.00

$210.00

$210.00

$170.00

$170.00

$185.00

$185.00

29.260.99 $100.00

CAN/ULC-D61230-99 Modification 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux sous tension -- Dispositifs Portables Pour la Mise à la Terre et la Continuité des Masses

La présente Norme nationale du Canada est équivalente à la Norme internationaleCEI/IEC 61230: 1993.Cette Norme s'applique aux dispositifs portables s'accrochant àun point fixe ou non, pour mise temporaire à la terre ou mise à la terre et encourt-circuit des réseaux électriques alternatifs hors tension, de transport et de distribution incluant les réseaux de chemins de fer, et ce, pour laprotection des travailleurs.

13.260 29.240.20

29.260.99

CAN/ULC-D61235-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live working -- Insulating Hollow Tubes for Electrical Purposes

This Standard is applicable to insulating hollow tubes made of synthetic materials and intended for tools and equipment for work on systems operating at voltages above 1 kV.

13.260 29.240.20

29.260.99

CAN/ULC-D61235-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux Sous Tension -- Tubes Creux Isolants Pour Travaux Electriques

Cette norme s'applique aux tubes creux isolants réalisés enmatériaux synthétiques et destinés à la fabrication d'outils et de matérielspour travaux sur réseaux de tension de service au-dessus de 1 kV.Des normes techniques particulières séparées donnent le détail des essais desembouts et outils adaptables montés sur partie terminale ou sur outils complets en tube creux.

13.260 29.240.20

29.260.99

CAN/ULC-D61236-99 Amendment 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Saddles, Pole Clamps (Stick Clamps) and Accessories for Live Working

This National Standard of Canada is equivalent to International Standard CEI/IEC 61236: 1993. This International Standard is applicable to saddles and pole clamps (stick clamps) used for live working, and to their accessories. It specifies the dimensional and mechanical characteristics to be given by the manufacturer for each too, the corresponding mechanical tests, and the other points to be checked (visual, functional, marking, etc.).

13.260 29.240.20

29.260.99

CAN/ULC-D61236-99Modification 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Selles, manchons et accessoires pour travaux sous tension

La présente Norme nationale du Canada est équivalente à la Norme internationale CEI/IEC 61236: 1993. Domaine d'applicationLa présente Norme internationale est applicable aux selles et manchons utiliséspour les travaux sous tension, ainsi qu'à leurs accessoires.Elle prescrit: - les caractéristiques dimensionnelles et mécaniques à spécifier par le fabricant pour chaque outil; - les essais mécaniques correspondants; - les autres points à contrôler (visuels, fonctionnels, marquage, etc.).

13.260 29.240.20

29.260.99

CAN/ULC-D61243-1-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live working -- Voltage detectors -- Part 1: Capacitive type to be used for voltages exceeding 1kV a.c.

This Standard is applicable to portable voltage detectors, with or without built-in power sources, to be used on electrical systems for voltages of 1 kV to 52 kV a.c., and frequencies from 15 Hz to 60 Hz. It applies only to capacitive voltage detectors used in contact with the part to be tested, as a single unit including its insulating pole as covered by CAN/ULC-D61235-00 or CAN/ULC-D60855-00, or as a separate device completed by an adaptable insulating pole covered by CAN/ULC-D61235-00 or CAN/ULC-D60855-00.

13.260 29.240.20

29.260.99

CAN/ULC-D61243-1-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux sous tension -- Détecteurs de tension -- Partie 1: Détecteurs de type capacitif pour usage sur des tensions alternatives de plus de 1 kV

Cette norme est applicable aux détecteurs de tension portatifs avec ou sans alimentation incorporée pour utilisation sur réseaux électriques de tensions alternatives de 1 kV à 52 kV, et de fréquences de 15 Hz à 60 Hz. Elle s'applique uniquement aux détecteurs de tension capacitifs utilisés en contact avec la pièce à essayer, en une seule partie, perche isolante comprise, couverte par la CAN/ULC-D61235-00 ou la CAN/ULC-D60855-00, ou en dispositif séparé complété par une perche isolante adaptable couverte par la CAN/ULC-D61235-00 ou la CAN/ULC-D60855-00.

13.260 29.240.20

29.260.99

CAN/ULC-D61243-2-99Amendment 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live working -- Voltage Detectors -- Part 2: Resistive Type to be Used for Voltages Exceeding 1 kV to 36 kV a.c.

This part of IEC 1243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. /This part applies only to resistive voltage detectors used in contact with the part to be tested, as a single unit or as a separate device completed by an adaptable insulating pole covered in IEC 855 or IEC 1235.

13.260 29.240

29.260.99

CAN/ULC-D61243-2-99Modification 1

Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux Sous Tension -- Détecteurs de Tension -- Partie 2: Type Résistif Pour Usage sur des Tensions Alternatives de 1 kV à 36 kV

La présente partie de la CEI 1243 est applicable aux détecteurs de tensionportatifs avec ou sans alimentation incorporée pour utilisation sur réseauxélectriques de tensions alternatives de 1 kV à 36 kV, et de fréquences de 15 Hzà 60 Hz.Cette partie s'applique uniquement aux détecteurs de tension résistifs utilisésen contact avec la pièce à essayer, en une seule partie ou en dispositif séparécomplété par une perche isolante adaptable conforme à la CEI 855 ou à la CEi1235.

13.260 29.240

29.260.99

CAN/ULC-D61243-3-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live working -- Voltage Detectors -- Part 3: Two-Pole Low-Voltage Type

This part of IEC 61243 is applicable to two-pole voltage detectors to be used on electrical systems for nominal voltages not exceeding 1 000 V a.c. and/or 1500 V d.c. and below 500 Hz (nominal frequencies).

13.260 29.240.20

29.260.99

CAN/ULC-D61243-3-00Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux Sous Tension -- Détecteurs de Tension -- Partie 3: Type Bipolaire Basse Tension

La présente partie de la CEI 61243 concerne les détecteurs de tension-bipolaireutilisés sur les systèmes électriques dont les tensions nominales n'excèdentpas 1 000 V en courant alternatif et/ou 1 500 V en courant continu, et qui sesituent sous 500 Hz (fréquences nominales).

13.260 29.240.20

29.260.99

CAN/ULC-D61278-03Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live Working - Guidelines for Dielectric Testing of Tools and Equipment

This guide is intended to define the parameters to be used in the development of standards related to tools and equipment used in live working.

Page 26: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 26 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

29.260.99 $100.00

$100.00

$100.00

$185.00

$185.00

$60.00

$60.00

$110.00

$110.00

CAN/ULC-D61278-03Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux Sous Tension – Guide Pour Les Essais Dielectriques des Outils et Equipements

Ce guide a pour objet les paramètres a utiliser dans la préparation des normes relatives aux outils et équipements utilises dans les travaux sous tension.

CAN/ULC-61318-03Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Live Working -Guideline for Quality Assurance Plans

This Technical Report establishes the guidelines for the plans and procedures assuring the quality of tools and equipment used for live working on electrical insatallations. The report incorporates the concept of quality assurance based on the ISO 9000 series and also integrates a single sampling plan and procedure using normal inspection and special inspection levels based on IEC 410.

13.340.01 29.260.99

CAN/ULC-61318-03Please note that this standard is bilingual:

English - French/A noter que cette norme est bilingue

français - anglais

Travaux Sous Tension – Guide Pour Les Plans D’Assurance De La Qualite

Le présent rapport technique fournit les plans et procédures faisant partie des normes pour assurer la qualité des outils pour travaux sous tension utilises sur des installations électriques. Ce rapport incorpore le concept d’assurance de la qualité apparaissant dans les normes de la série 9000 de l’ISO et integre aussi les plans et règles d’échantillonnage simple en contrôle normal et spécial de la CEI 410

13.340.01 29.260.99

CAN/ULC-61328-05(CEI/IEC/TR 61328:2003, IDT)

Please note that this standard is bilingual: English - French/À noter

que cette norme est bilingue français - anglais

Live Working - Guidelines for the Installation of Transmission Line Conductors and Earthwires - Stringing Equipment and Accessory Items

This National Standard of Canada provides recommendations for the selection and testing where necessary of conductor stringing equipment and accessory items used for the installation of overhead conductors and overhead earthwires. Procedures are recommended for proper earthing in order to protect equipment, components and personnel from the induced or fault currents which can result in some circumstances.The equipment under consideration in this National Standard of Canada is used for transmission voltages which are usually considered to be 100 kV and above, but may be as low as 60 kV. Many of the requirements and tests stated apply also to equipment used in distribution systems with less than 100 kV.

13.260 29.240.20

29.260.99

CAN/ULC-61328-05(CEI/IEC/TR 61328:2003, IDT)

Please note that this standard is bilingual: English - French/À noter

que cette norme est bilingue français - anglais

Travaux Sous Tension – Lignes directrices pour l'installation des conducteurs et câbles de garde des lignes de transport - Équipement de déroulage et accessoires

La présente Norme nationale du Canada fournit des recommandations pour le choix et l'essai, lorsque cela est nécessaire, des matériels de déroulage et des accessoires utilisés pour l'installation des conducteurs et câbles de garde aériens.Des procédures sont recommandées pour une mise à la terre adéquate afin de protéger l'équipement, les composants et le personnel des courants induits ou des courants de défaut pouvant survenir dans certaines circonstances.L'équipement concerne par la présente Norme nationale du Canada est utilisé pour des tensions de transport, qui sont généralement considérées comme étant égales ou supérieures a 100 kV, mais qui peuvent être aussi �basses que 60 kV. Un grand nombre des exigences et des essais spécifiés s'applique aussi à des équipements utilisés pour des réseaux de distribution de tension inférieure a 100 kV.

13.260 29.240.20

29.260.99

CAN/ULC-61477-05(CEI/IEC 61477:2001+A1:2002,

IDT)

Please note that this standard is bilingual: English - French/

À noter que cette norme est bilingue français - anglais

Live Working - Minimum Requirements for the Utilization of Tools, Devices and Equipment

This National Standard of Canada gives the minimum requirements relative to specification, manufacture, selection, application and maintenance of tools, devices and equipment for live working. It provides the type of information which is useful to skilled persons in order to make the use of tools, devices and equipment safer. This type of information includes:· the characteristics of tools, devices and equipment;· their conditions for use;· their conditions for maintenance;· their conditions for storage and transportation. Such information may be given in standards, manufacturer’s instructions for use and in internal regulations set forth by companies for their own employees. Such information should be complemented by work methods, which are excluded from the scope of this standard. In this standard, the word tool(s) is used for "tools, devices and equipment for live working" unless otherwise specified.

13.260 29.240.20

29.260.99

CAN/ULC-61477-05(CEI/IEC 61477:2001+A1:2002,

IDT)

Please note that this standard is bilingual: English - French/

À noter que cette norme est bilingue français - anglais

Travaux Sous Tension – Exigences Minimales pour L'utlisation des Outils, Dispositifs et Équipements

La présente Norme nationale du Canada donne les exigences minimales relatives aux spécifications, à la fabrication, à la sélection, à l’emploi et à l’entretien des outils, dispositifs et équipements pour travaux sous tension. Elle fournit le type d’information utile aux personnes formées de façon à rendre plus sûre l’utilisation des outils, dispositifs et équipements pour travaux sous tension. Ce type d’information comprend:· les caractéristiques des outils, dispositifs et équipements;· leurs conditions d’utilisation;· leurs conditions d’entretien;· leurs conditions d’entreposage et de transport. Ces informations peuvent figurer dans les normes, les instructions d’emploi des fabricants, les règlements internes établis par les entreprises pour leurs employés. Il convient que ces informations soient complétées par des méthodes de travail, lesquelles sont exclues du domaine d’application de cette norme. Dans cette norme, le mot «outils» est utilisé pour «outils, dispositifs et équipements pour travaux sous tension» sauf indication contraire.

13.260 29.240.20

29.260.99

CAN/ULC-61478-05(CEI/IEC 61478:2001+A1:2003,

IDT)

Please note that this standard is bilingual: English - French/

À noter que cette norme est bilingue français - anglais

Live Working - Ladders of Insulating Material

This National Standard of Canada is applicable to fully insulating spliced or hook ladders with extension or having a combination of insulating and conductive sections and used for live working on a.c. or d.c. electrical installations at 1 000 V and above for a.c. and 1 500 V and above for d.c. The ladders are classified functionally as Category 1 and Category 2. This standard concerns only ladders made of synthetic material. These ladders are used, to provide access, generally on overhead line structures and to facilitate live working, either hot stick, barehanded or a combination of both.

13.260 29.240.20

29.260.99

CAN/ULC-61478-05(CEI/IEC 61478:2001+A1:2003,

IDT)

Please note that this standard is bilingual: English - French/

À noter que cette norme est bilingue français - anglais

Travaux Sous Tension – Échelles en Matériau Isolant

La présente Norme nationale du Canada s’applique aux échelles entièrement isolantes (échelles à éléments emboîtables ou échelles à crochets avec rallonge) ou comportant une combinaison d’éléments conducteurs et d’éléments isolants et utilisées pour les travaux sous tension sur des installations électriques en courant alternatif ou continu ayant une tension nominale égale ou supérieure à 1 000 V en alternatif et à 1 500 V en continu. Les échelles sont classées fonctionnellement en Catégorie 1 et Catégorie 2. La présente norme ne concerne que les échelles réalisées en matériau synthétique. Ces échelles sont utilisées pour permettre l’accès généralement sur des supports de lignes aériennes et faciliter les travaux sous tension, que ce soit à distance, au potentiel, ou une combinaison des deux.

13.260 29.240.20

29.260.99

Page 27: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 27 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$120.00

$120.00

$155.00

$155.00

ULC/ORD-C10(c)-1986 $110.00

ULC/ORD-C14(e)-M1985 $110.00

ULC/ORD-C25-1992 $110.00

Safety Containers $110.00

ULC SUBJECT C47-1973 $110.00

CAN/ULC-61479-05(CEI/IEC 61479:2001+A1:2002,

IDT)

Please note that this standard is bilingual: English - French/

À noter que cette norme est bilingue français - anglais

Live working - Flexible Conductor Covers (Line Hoses) of Insulating Material

This National Standard of Canada is applicable to flexible insulating covers (line hoses) for the protection of workers from accidental contact with live or earthed electrical conductors and for the avoidance of short circuits during live working. Five classes of conductor covers, differing in electrical characteristics, are provided and designated as class 0, class 1, class 2, class 3, and class 4. Six categories of conductor covers differing in composition and properties are provided: category A – acid resistant, category H – oil resistant, category C – formulated for extreme low temperature environments, category W – formulated for extreme high temperature environments, category Z – ozone resistant, and category P – formulated for humid environment. Various styles of conductor covers, differing in construction characteristics are available and six of these are designated as style A, style B, style C, style D, style E, (see figure 1), and style F.

13.260 29.240.20

29.260.99

CAN/ULC-61479-05(CEI/IEC 61479:2001+A1:2002,

IDT)

Please note that this standard is bilingual: English - French/

À noter que cette norme est bilingue français - anglais

Travaux Sous Tension – Protecteurs de conducteurs flexibles en matériau isolant

La présente Norme nationale du Canada est applicable aux protecteurs flexibles isolants destinés à protéger les travailleurs d’un contact accidentel avec des conducteurs électriques sous tension ou à la terre et à éviter les courts-circuits pendant les travaux sous tension. Cinq classes de protecteurs de conducteurs, de caractéristiques électriques différentes, sont disponibles sous la désignation de classe 0, classe 1, classe 2, classe 3 et classe 4. Six catégories de protecteurs de conducteurs, ayant une composition et des propriétés différentes sont disponibles: catégorie A – pour la résistance à l'acide, catégorie H – pour la résistance à l'huile, catégorie C – pour les environnements de très basses températures, catégorie W – pour les environnements de très hautes températures, catégorie Z – pour la résistance à l'ozone et catégorie P – pour l’environnement humide. Des styles de protecteurs de conducteurs, différents par leurs caractéristiques constructives, sont disponibles et six de ces styles sont désignés comme style A, style B, style C, style D, style E, (voir figure 1), et style F.

13.260 29.240.20

29.260.99

CAN/ULC-61911-05(CEI/IEC 61911:2003, IDT)

Please note that this standard is bilingual: English - French/À noter

que cette norme est bilingue français - anglais

Live Working - Guidelines for the Installation of Distribution Line Conductors - Stringing Equipment and Accessory Items

This National Standard of Canada provides recommendations for the selection and testing, where necessary of conductor stringing equipment and accessory items used for the installation of bare and insulated overhead distribution conductors.

Procedures are recommended for proper earthing in order to protect equipment, components and personnel from currents which can result from accidental contact with nearby energized conductors, or induced voltage from adjacent energized lines, lightning strikes, switching errors or electrostatic charging..

The equipment under consideration in this National Standard of Canada is used for distribution voltages, usually considered to be below 50 kV.

However for voltages of 50 kV and above, use of Standard CAN/ULC-61328-05 may be more appropriate. The choice of whether Standard CAN/ULC-61328-05 or this National Standard of Canada applies to the work being considered will usually depend on the physical size of the conductors, the size of the structures and the average span between supports.

13.260 29.240.20

29.260.99

CAN/ULC-61911-05(CEI/IEC 61911:2003, IDT)

Please note that this standard is bilingual: English - French / À noter

que cette norme est bilingue français - anglais

Travaux Sous Tension – Lignes directrices pour l'installation des conducteurs des lignes de distribution - Équipement de déroulage et accessoires

La présente Norme nationale du Canada fournit des recommandations pour le choix et l'essai, lorsque cela est nécessaire, des matériels de déroulage et des accessoires utilisés pour l'installation de conducteurs nus et isolés de lignes aériennes de distribution.

Des procédures sont recommandées pour une mise à la terre adéquate afin de protéger l'équipement, les composants et le personnel des courants pouvant résulter de contacts accidentels avec des conducteurs sous tension voisins, ou d'une tension induite par des lignes sous tension adjacentes, de coups de foudre, d'erreurs de manœuvre ou d'une charge électrostatique.

L'équipement a l'étude dans cette Norme nationale du Canada est utilisé pour des tensions de distribution, généralement considérées comme étant inférieures a 50 kV.

Cependant, pour des tensions supérieures ou égales a 50 kV, l'emploi de la norme CAN/ULC-61328-05 peut être plus appropriée. Le choix entre la norme CAN/ULC-61328-05 et la présente Norme nationale du Canada pour les travaux considérés dependra généralement de la taille physique des conducteurs, de la taille des structures et de la distance moyenne entre les supports.

13.260 29.240.20

29.260.99

Guide for Evaluating Doors and Frames for Listing and Labelling

These requirements are primarily for use by manufacturers of doors and door frames. These requirements cover the CAN4-S104 test evaluations for swinging and sliding doors and door frames. Listings will be based on the largest size of assembly tested and the maximum duration of test.

19.040 19.060

91.060.50 

Guide for Hardware for Fire Doors and Emergency Exits

This Guide covers the test requirements for hardware intended for use on fire doors and emergency exits for swinging and sliding doors. These requirements shall pertain to both fire protection and panic features. This Guide does not cover non-essentials such as push plates, pullhandles, protective plates, plant-ons, etc.

91.190 

Meters for Flammable and Combustible Liquids and Propane

These requirements cover positive displacement meters for flammable and combustible liquids and propane in the liquid phase. These requirements do not cover: meters for use with propane in the gaseous phase; velocity meters, head meters, or area meters; and meter components incorporating electrical circuits.

17.120 75.200 

ULC/ORD-C30-1995  These Requirements cover portable safety containers intended for the temporary storage and handling of small quantities (up to 25 L) of flammable and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0.

55.140 75.200 

Preliminary Standard for Fire Hose Rack Assemblies

These requirements cover semiautomatic hose rack assemblies and component parts for such assemblies intended for use in controlling incipient fires by occupants of buildings or those untrained in handling fire streams.

13.220.3023.040.70

Page 28: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 28 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C48.1-01 NA $110.00

$140.00

ULC/ORD-C58.9-1997 $110.00

ULC/ORD-C58.10-1992 $110.00

$110.00

$110.00

$110.00

$110.00

ULC/ORD-C58.20-1996 $110.00

Installation of Field Assembled Skeletal Neon Signs and Outline Lighting

This Document contains the requirements for installation of field assembled skeletal neon signs and outline lighting systems, and is to be used in conjunction with the following documents:

A C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1; andB CAN/CSA-C22.2 No. 207, Portable and Stationary Electric Signs and Displays.

This Document is intended to provide evaluation of the electrical equipment and interconnecting wiring comprising of complete field assembled skeletal neon signs and outline lighting systems that otherwise are not intended to be evaluated in accordance with CSA SPE-1000 (Model Code for the Field Evaluation of Electrical Equipment), or to be certified in conformance with CSA-C22.2 No.207 (Portable and Stationary Electric Signs and Displays).

These systems are intended to be field assembled for permanent installation in accordance with Section 34 (Signs and Outline Lighting) of CSA C22.1 (Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1) and this Document.

The installation of skeletal neon signs or outline lighting systems complying with this Document:

A Have been assembled and installed by an installer authorized to apply a recognized certification mark; B Employs materials and components certified in accordance with Canadian Standards; and C Is subject to a field inspection program covering proper installation of the system.

ULC/ORD-C58.4-05 Double Containment Fibre Reinforced Plastic Linings for Flammable and Combustible Liquid Storage Tanks

These requirements provide the minimum performance criteria for double containment linings used for new and existing aboveground and underground non-pressure storage tanks made of steel or non-metallic construction for flammable and combustible liquids. Aboveground tanks shall be with secondary containment in accordance with the requirements of the National Fire Code of Canada or the regulations of the authority having jurisdiction.The linings may be used to upgrade a new or existing tank through the addition of a liquid tight layer to the interior of the tank and by providing a monitorable interstice between this interior layer and the external tank wall at all locations below the normal liquid level of the tank.

The linings are constructed of fibreglass reinforced plastic materials. These linings provide protection against internal corrosion or chemical attack to new or existing tanks.

The linings may be used to provide leak detection and structural upgrade to existing tanks.

The linings are intended for use in the construction, refurbishment, or upgrade of tanks manufactured in accordance with the applicable requirements of any one of the following Standards:

A ULC-S601, Standard for Shop Fabricated Steel Aboveground Horizontal Tanks for Flammable and Combustible Liquids; or

B ULC-S615, Standard for Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids.

23.020.10, 25.220.99

Secondary Containment Liners for Underground and Aboveground Flammable and Combustible Liquid Tanks

The following requirements provide the minimum criteria for the material properties and performance of Secondary Containment Liners (referenced in this document as "Liners") for use below and around underground and aboveground flammable and combustible liquid and other specific chemical storagetanks facilities. These requirements cover pre-fabricated lining materials and liners which are field formed utilising spraying techniques.

75.200 

Jacketed Steel Underground Tanks for Flammable and Combustible Liquids

These requirements cover cylindrical horizontal steel tanks of the non-pressure type which are: manufactured in accordance with the applicable requirements of the Standard for Steel Underground Tanks for Flammable and Combustible Liquids, CAN4-S603M; used for the underground storage of flammable and combustible liquids such as gasoline, fuel oil, and similar products; and provided with corrosion protection in accordance with the requirements contained in this Document, as an alternative to the protection specified in the Standard for Galvanic Corrosion Protection Systems for Underground Tanks for Flammable and Combustible Liquids, CAN4-S603.1.M.

23.020.10 

ULC/ORD-C58.12-1992  Leak Detection Devices (Volumetric Type) for Underground Flammable Liquid Storage Tanks

These requirements cover equipment for the detection of leakage from underground flammable liquid storage tanks by directly or indirectly measuring the presence of liquid, or changes in the level of liquid over a period of time. These requirements provide for the determination of the capability of equipment for the measurement of actual or potential leakage rates within defined statistical probabilities. These requirements do not cover non-volumetric leak detection equipment or methods.

17.060 23.020.10

75.200 

ULC/ORD-C58.14-1992  Non-Volumetric Leak Detection Devices for Underground Flammable Liquid Storage Tanks

These requirements cover equipment and procedures for the detection o leakage from underground flammable liquid storage tanks by qualitative characteristic assessment of leakage, changes in the volume in a qualitative manner or the presence of product external to the tank. These requirements provide for the determination of the capability of equipment and procedures for the measurement of actual or potential leakage within defined statistical probabilities. These requirements do not cover quantitative volumetric leak detection equipment or methods.

17.060 23.020.10

75.200 

ULC/ORD-C58.15-1992  Overfill Protection Devices for Flammable Liquid Storage Tanks

These requirements cover equipment and procedures for the detection o leakage from underground flammable liquid storage tanks by qualitative characteristic assessment of leakage, changes in the volume in a qualitative manner or the presence of product external to the tank. These requirements provide for the determination of the capability of equipment and procedures for the measurement of actual or potential leakage within defined statistical probabilities.These requirements do not cover quantitative volumetric leak detection equipment or methods.

23.020.10 23.060

75.200 

ULC/ORD-C58.19-1992  Spill Containment Devices for Underground Flammable Liquid Storage Tanks

The following requirements provide the minimum criteria for the construction and performance of Spill Containment Devices for Underground Flammable Liquid Storage Tanks

23.020.10 55.120

75.200 

Special Corrosion Protection Underground Tanks for Flammable and Combustible Liquids

These requirements cover cylindrical horizontal steel tanks of the non-pressure type which are: manufactured in accordance with the applicable requirements of the Standard for Steel Underground Tanks for Flammable and Combustible Liquids, CAN/ULC-S603M; provided with a factory-applied corrosion protection coating in accordance with the requirements contained in this Document as an alternative to the protection specified in the Standard for Galvanic Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids, CAN/ULC-S603.1; and used for the underground storage of flammable and combustible liquids such as gasoline, fuel oil, and similar products.

25.220 

Page 29: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 29 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C72-1992 $110.00

ULC/ORD-C79.1-04 $110.00

$140.00

ULC/ORD-C100-1992 $110.00

$110.00

ULC/ORD-C107.12-1992 $110.00

Under-Dispenser Sumps $110.00

$110.00

ULC/ORD-C125-1992 $110.00

Composite Fire-Logs $110.00

$110.00

ULC/ORD-C132-1992 $110.00

ULC/ORD C140-1974 $110.00

ULC/ORD-C142.6-2000 Storage Vaults $110.00

Tests for Fire Resistance of Record Protection Equipment

These requirements cover the test procedure applicable to the fire-resistance classification of record protection equipment intended to provide protection to one or more types of records when exposed to various durations of fire exposure.

13.220.40 19.040

97.140 

Manual Pumps For Use With Liquid Petroleum Fuels

These requirements apply to manual pumps intended to be used with liquid petroleum fuels such as gasoline, diesel or kerosene. The intended use of this pump is to transfer petroleum fuel from a certified portable container, with a maximum capacity of 25 L, to equipment such as chainsaws, lawn mowers, lawn tractors and yard maintenance equipment, that would normally be refueled from a portable gasoline container. The pumps are intended to reduce spillage when used for the purpose stated above. This document is not a fire hazard document  

23.080 75.200

75.160.20

ULC/ORD-C80.1-2000+A389

Aboveground Non-Metallic Tanks for Fuel Oil

This ORD provides the minimum criteria for the material properties and performance of aboveground non-metallic tanks of the stationary non-pressure type intended for installation inside or outside buildings, for the storage and supply of fuel oil.

These requirements cover single wall tanks and tanks with secondary containment. They cover the design and construction of non-metallic fuel oil storage tanks up to 2 500 L capacity. Tanks of fibreglass construction, in addition to these requirements, shall meet the applicable requirements of the Standard for Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids, ULC-S615.

These requirements cover tanks fabricated, inspected and tested for leakage before shipment from the factory. These requirements cover the construction of tanks for use in stationary installations. The installation of such tanks may be covered by, but not limited to, any of the following documents:

A CSA B139, Installation Code for Oil Burning Equipment; B Regulations of the appropriate Authority Having Jurisdiction; and C Environmental Code of Practice for Aboveground Storage Tank Systems Containing Petroleum Products.

23.020.1075.160.20

Smoke Control System Equipment

These requirements cover the design, construction and performance of Smoke Control System Equipment, including such devices as the system control unit, emote control units, operator interface devices andfirefighter's smoke control station. Since smoke control systems are specially designed to meet the specific needs of an individual building and its occupants, this document does not include requirements covered by the Authorities Having Jurisdiction.

13.040 13.220.30 

ULC Subject C107-1975  Guide for the Investigation of Asbestos-Cement Pipe and Couplings

These requirements cover asbestos-cement pressure pipe, couplings, and gaskets for use in public and private water works and fire service systems and connections to such systems.

23.040.30 

Line Leak Detection Devices for Flammable Liquid Piping

These requirements cover equipment for the detection of leakage from underground flammable liquid pipeline systems by directly or indirectly measuring changes in the volume or pressure of the liquid in the system over a period of time.

23.040.01 75.180.30 

ULC/ORD-C107.21-1992  These requirements cover sumps which are intended to be installed under a dispensing device for flammable liquids to collect and contain any internal liquid leaking from the dispensing device during operation or routine maintenance.

75.200 

ULC Subject C123-1975  Guide for the Investigation of Torches, Oxy-Fuel Gas

These requirements cover oxy-fuel gas torches employed in operations such as welding, cutting, heating,scarfing, powder cutting, or other allied processes. These requirements do not apply to torches in which the fuel gas aspirates atmospheric air or to metal-spraying torches.

25.060.20 

Valves for Anhydrous Ammonia and Propane (Other than Safety Relief)

These requirements cover the following types of anhydrous ammonia and propane valves: Shutoff Valves; Excess Flow Valves; Back Pressure Check Valves; Filler Valves; and Vapour Return Valves. These requirements do not apply to propane valves for use on containers or in systems for refrigerated storage systems or marine and pipeline terminals, chemical plants, natural gas processing plants, refineries or tank farms, where "tank farms" do not include storage at industrial locations. These requirements do not apply to valves for anhydrous ammonia or use on containers or in systems for the following: refrigerated storage systems; ammonia manufacturing plants; refrigeration plants where ammonia is used solely as a refrigerant; or ammonia transportation pipelines.

23.060 75.200 

ULC/ORD-C127-M1990  These requirements cover composite fire logs having a maximum mass of 3 kg for use in designated certified solid fuel burning appliances and masonry fireplaces.

75.160.10 

ULC/ORD-C127.1-1993  Composite Fire-Log Starters

These requirements cover composite fire-log starters for use in residential factory-built solid fuel burning appliances and masonry fireplaces.

97.180 

Safety Relief Valves for Anhydrous Ammonia and Propane

These requirements cover safety relief valves and hydrostatic relief valves for anhydrous ammonia and propane for use in non-refrigerated systems in facilities covered by the following Standards: ANSI K61.1, Storage and Handling of Anhydrous Ammonia; CAN/CGA-B149, Propane Installation Code; and NFPA No. 59, Storage and Handling of Liquefied Petroleum Gases at Utility Plants. These requirements do not apply to safety and relief valves for use on containers constructed in accordance with Canadian Transport Commission (CTC) Specifications.

23.060 75.200 

Guide for Investigation of Relocking Devices

These requirements cover relocking devices which primarily are intended to relock the boltwork of doors or relock the door of a safe, chest, or vault in the event of burglarious attack on the combination lock. The devices may include interior unlocking or escape mechanisms intended to readily release the boltwork by persons locked within the vault but shall not detract from the protection afforded. These requirements cover devices intended for factory installation on doors.

13.310 21.060.30 

These requirements provide the minimum criteria for the construction and performance of storage vaults intended for outdoor installation for the storage and collection, and optionally, dispensing of small quantities of flammable and combustible liquids in and from containers and portable tanks built in conformance with: drums as defined in the "Transportation of Dangerous Goods Regulations"; CSA B376-M, "Portable Containers for Gasoline and other Petroleum Fuels"; CSA B306-M, "Portable Fuel Tanks for Marine Use"; and ULC/ORD-C30, "Safety Containers". These requirements apply to storage vaults not more than one storey in height and not greater than 100 m² in floor area.

23.020.10 75.200 

Page 30: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 30 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$110.00

ULC/ORD-C142.15 Precast Concrete Tanks NA $110.00

$110.00

ULC/ORD-C142.18-1995 $110.00

ULC/ORD-C142.19-1994 $110.00

ULC/ORD-C142.20-1995 $110.00

$110.00

ULC/ORD-C142.22-1995 $110.00

ULC/ORD-C142.5-1992 $110.00

$110.00

WITHDRAWN 2006 WITHDRAWN

$110.00

ULC/ORD-C180-97 $110.00

$110.00

$110.00

ULC/ORD-C142.14-03 Amendment 1

Nonmetallic Bulk Containers For New Lubricating Oil

The following requirements provide the minimum criteria for the material properties and performance of nonmetallic containers of the non-pressure type, intended to bulk store and dispense combustible (such as new lubricating oil) and non-combustible liquids (such as windshield washer fluid, anti-freeze, etc.). These requirements cover single wall containers or containers with secondary containment, that dispense liquids by way of gravity or by a non-pressure type pump (hand or air-operated).

These requirements cover the design and construction of nonmetallic containers up to 2500 L nominal capacity.These requirements cover containers fabricated, inspected and tested for leakage before shipment fromthe factory.These requirements cover the construction of containers for use in stationary installations inside buildings, mainly in automotive repair and service centres and shops.The installation of such containers may be covered by any of the following documents: A National Fire Code of Canada, Part 4; B Regulations of the appropriate authority having jurisdiction.

23.020.10 75.080

These requirements cover stationary aboveground and underground precast concrete tanks, and underground vaults.

These requirements cover: A Tanks intended for use as primary containment for liquids that are non-destructive to concrete, such as water contaminated with oil, waste water, or similar products; and, B Tanks and vaults intended for use as secondary containment for flammable and combustible liquids.

This document is a companion document to CAN/ULC-S656, Standard for Oil-Water Separators.

This document is a reference document for manufacturing precast concrete tanks, such as "Protected Tanks, ULC-S655" and "Secondary Containments for Aboveground Flammable and Combustible Liquid Storage Tanks, ULC/ORD-C142.20."

These requirements cover below-grade vaults intended for the storage of flammable and combustible liquids in an aboveground tank.

ULC/ORD-C142.17-1998  Special Purpose Relocatable Aboveground Vertical Tanks for Flammable and Combustible Liquids

These requirements cover special purpose relocatable aboveground vertical steel storage tanks of the non-pressure type that are used for the bulk storage of flammable and combustible liquids with a relative density of not greater than 1.0, such as gasoline, fuel oil or similar products.

23.020.10 23.020.99 

Rectangular Steel Aboveground Tanks for Flammable and Combustible Liquids

These requirements cover single wall steel tanks and tanks with secondary containment (either double-walled or contained) of the rectangular non-pressure design that are used for the aboveground storage of flammable and combustible liquids such as gasoline, fuel oil, diesel fuel or similar products with a relative density not greater than 1.0.

23.020.10 

Spill Containment Devices for Aboveground Flammable and Combustible Liquid Storage Tanks

These requirements provide the minimum criteria for the construction and performance of Spill Containment Devices for Aboveground Flammable and Combustible Liquid Storage Tanks.

23.020.10 75.200 

Secondary Containment for Aboveground Flammable and Combustible Liquid Storage Tanks

These requirements cover secondary containments for aboveground primary tanks intended for the storage of flammable and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0.

23.020.10 75.200 

ULC/ORD-C142.21-1995  Aboveground Used-Oil Systems

These Requirements provide the minimum criteria for aboveground used oil systems that eliminate, to a large extent, the manual handling of used oil.

23.020.99 23.080

75.200 

Contained Vertical Steel Aboveground Tank Assemblies for Flammable and Combustible Liquids

These requirements cover contained vertical steel aboveground tank assemblies that are used for the storage of flammable and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0.

23.020.10 75.200 

Concrete Encased Steel Aboveground Tank Assemblies for Flammable and Combustible Liquids

These requirements cover concrete encased tank assemblies, maximum capacity 40 000 L, for the outdoor aboveground storage of flammable and combustible liquids such as gasoline, fuel oil, or similar products with a relative density not greater than 1.0.

23.020.1091.100.30

ULC Subject C144-1975  Guide for the Investigation of Pressure-Regulating Valves

These requirements cover pressure regulators for use with LP-Gas equipment other than automotive. They are not intended to cover regulators for utility gas plants or petroleum refineries, chemical process uses, or regulators for use in gas-welding and cutting operations.

23.060.40 

ULC/ORD-C147-1975WITHDRAWN MARCH 2006

Guide for the Investigation of LP-Gas Torches

25.160.50 75.160.30 

ULC Subject C155-1975  Preliminary Standards for Tests for Fire Resistance of Vault and File Room Doors

These requirements cover the test procedure for the fire-resistance classification of doors intended for the protection of openings of vaults and file rooms. The requirements do not cover other possible hazard aspectsof such products.

13.220.50 19.040

91.060.50 

Liquid Level Gauges and Indicators for Fuel Oil and Lubricating Oil Tanks

These requirements cover liquid-level gauges and indicators for use on vented tanks used for the storage of fuel oil and lubricating oil.

75.180.99 

ULC Subject C193-1975  Guide for the Investigation of Alarm Valves for Fire-Protection Service

These requirements cover alarm valves for use in automatic wet-pipe sprinkler systems for fire-protection service. Alarm valves covered by these requirements are of either the variable- or constant-pressure type and are of the swing-check pattern. Ordinarily, variable-pressure alarm valves will prove suitable for constant-pressure service without alteration, but in certain designs that portion of the device which has to do with the delaying of alarmsmay be omitted.

13.220.20 13.320 

ULC Subject C194-1975  Guide for the Investigation of Gasketed Joints for Cast-Iron Pressure Pipes and Fittings

These requirements cover gasketed joints of cast-iron pipe and fittings, 2-48 inches in diameter, for conveying water in public and private waterworks and fire service systems.

23.040.10 23.040.40

23.040.80 

Page 31: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 31 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C199D-03 Guards for Sprinklers 13.220.20 $110.00

ULC/ORD-C199P-02 These requirements cover combustible pipe and fittings for use in sprinkler systems for fire protection service. $110.00

These requirements cover light wall steel pipes for use in sprinkler systems. $110.00

ULC/ORD-C203-03 13.220.20 $110.00

ULC/ORD-C203A-1998 $110.00

ULC/ORD-C210C-M1986 NA $110.00

ULC/ORD-C213-1996 $110.00

ULC/ORD-C213B-03 Welded Outlet Fittings 13.220.20 $110.00

Door Closers and Holders $110.00

ULC/ORD-C252-1975 $110.00

ULC/ORD-C258-03 13.220.20 $110.00

$110.00

$110.00

$110.00

ULC/ORD-C263.1-99 $110.00

ULC/ORD-C263.5-99 $110.00

ULC/ORD-C263.7-2000 NA $110.00

ULC/ORD-C268.13-93 $110.00

These requirements cover sprinkler guards intended for installation in accordance with the Standard for the Installation of Sprinkler Systems, NFPA 13. The guards are to be installed on specific models of pendent, upright or intermediate level sprinklers as indicated in the installation instructions for the guards. The guards are intended to protect sprinklers from mechanical damage.  

Combustible Piping for Sprinkler Systems

13.220.20 23.040.20

23.040.45 

ULC/ORD-C199S-M1994  Light Wall Steel Pipes for Sprinkler Systems for Fire Protection Services

13.220.20 

Pipe Hanger Equipment for Fire Protection Service

These requirements cover the performance of pipe hanger equipment for use in supporting piping employed in sprinkler systems, water-spray systems, and other piping systems used for fire-protection service.These requirements cover design variations of hangers defined in Section 2, and do not cover products fabricated fromrods of iron or steel with diameters specified by the Standard for the Installation of Sprinkler Systems, NFPA 13, such as U-type hangers, hanger rods, coach screws, and similar products.  

Sway Brace Devices for Sprinkler System Piping

These requirements cover sway brace devices intended to protect sprinkler system piping against damage from earthquakes, when they are installed in accordance with the Standard for Installation of Sprinkler Systems, NFPA 13.

13.220.20 91.120.25 

Guide for Listing and Labelling of Factory-Built Chimney Connectors

These Requirements apply to Factory-Built Chimney Connectors which do not require field fabrication. They are for use with gas, liquid and solid fuel-fired residential appliances and building heating equipment where the flue-gas temperatures do not normally exceed 540 degrees C. They are intended for use inside buildings to form a connection to a type 650 degrees C factory-built or masonry chimney.

Rubber Gasketed Fittings for Fire Protection Service

These requirements cover rubber gasketed fittings, intended for joining and providing outlets from grooved or plain ended piping.

13.220.20 23.040.99 

These requirements covered welded outlet fittings for installation in accordance with the Standard for the Installation of Sprinkler Systems, NFPA 13.

ULC/ORD-C228-1995  This Document establishes requirements for door holding-closing equipment in the following arrangements: closer with a separately installed holder-release unit actuated by a signal from a separately installed smoke detector or other source; a single unit incorporating closing and holding-release functions actuated by a signal from a separately installed smoke detector or other source; or a single unit incorporating closing, holding-release, and smoke detection functions.

91.190 

Guide for the Investigation of Gas Pressure Regulators

These requirements cover pressure regulators which reduce the storage cylinder of line gas pressure to the use pressure. Regulators covered by these requirements are intended for use with (1) gases for welding and cutting operations, (2) inert gases, or (3) non-flammable medical gases.

23.020.30 23.060.40 

Shutoff Valves for Trim and Drain Purposes for Fire Protection Service

These requirements cover shutoff valves for trim and drain purposes for fire protection service. These valves are intended for installation in sprinkler systems in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems.

ULC Subject C260-1975  Guide for the Investigation of Dry Pipe, Deluge and Pre-Action Valves for Fire Protection

These requirements apply to valve equipment employed in piping systems to automatically supply water to dry pipe, deluge (empty pipe), and pre-action sprinkler systems for fire-protection service.

13.220.20 23.060 

ULC/ORD-C262-1992  Gate Valves for Fire Protection Service

These requirements cover gate valves employed in piping systems supplying water for fire-protection service. Gate valves may be of the outside-screw-and-yoke type or of the inside-screw non-rising stem type, the latter for installation either above or below ground.

13.220.20 23.060.30 

ULC Subject C263(e)-M1988  Criteria for Use in Extension of Data from Fire Endurance Tests

This document is based on generally accepted principles involving the extension of test data using simple considerations. The aceptance of these principles and their application is based substantially on what might be termed "an analogous worst case proposition"together with the consideration of precepts such as Ten Rules of Fire Endurance. These principles are applicable to assemblies subject to temperature conditions represented by the standard time-temperature curve described in CAN4-S101M.

19.040 

Sprinkler-Protected Windows Systems

This test method enables an assessment of the performance, under controlled fire exposure conditions, of a sprinkler protected window system.

13.220.99 19.060 91.060.50 

Exterior Insulation and Finish Systems (EIFS)

This describes the minimum performance criteria can be and minimum technical requirements applicable for the assessment of Exterior Insulation and Finish Systems (EIFS) Class PB and Class PM, consisting of prefabricated panels or panels constructed on-site.

25.220.20 

Room Fire Test Method for Garage Doors Using Foamed Plastic Insulation

This document describes the test method used to determine the contribution of garage doors using foamed plastic insulation to the creation of fire hazard under specified fire exposure conditions. The test is conductedin a standard room configuration.

The test method is to be used to evaluate the flammability characteristics of garage door assemblies using foamed plastic insulation employing materials or having forms of construction differing from those detailed below:

A Garage door assemblies using foamed plastic insulation when the foamed plastic is separated from occupied spaces by a facing of minimum 0.38 mm (0.015 in.) sheet metal with a melting point not below 650°C;

B Factory assembled garage door assemblies using thermosetting foamed plastics having a flame spread of not more than 200 , where the insulation is covered on the interior with metallic foil, and the flame spread rating of the factory assembled garage doors is not more than 2001 and no air spaces incorporated within the factory assembled garage door.

This test method is not intended to evaluate the fire endurance of assemblies, nor does it provide full information oncerning the toxicity of combustion gases or residues.

Smoke-Alarms for Mobile Homes and Recreational Vehicles

These requirements cover the design, construction, and performance of smoke-alarms for installations in mobile homes and recreational vehicles.

13.220.20 13.320

43.160 

Page 32: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 32 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C275.1-00 NA $110.00

$110.00

ULC/ORD-C312-07 $130.00

ULC/ORD-C321-03 Pipeline Strainers 13.220.20 $110.00

$110.00

$110.00

$110.00

$110.00

ULC SUBJECT C378-1975 $110.00

ULC/ORD-C386-1990 Flame Detectors These requirements cover the design, construction and performance of Flame Detectors rated at 300 V or less. $110.00

$110.00

$110.00

$110.00

$110.00

$110.00

ULC/ORD-C410A-1994 NA $110.00

ULC/ORD-C441-M1990 Pellet Vents $110.00

Gas Vent Connectors $110.00

Installation of Aftermarket Automobile Theft Deterrent Devices

These requirements are a set of recommended practices for installation facilities handling the installation of aftermarket automobile theft deterrent devices in light duty vehicles equipped with direct current (d.c.) electrical systems.

This ORD is intended to assist in the implementation of the requirements of the Standard for Automobile Theft Deterrent Equipment and Systems: Electronic Immobilization, CAN/ULC-S338-98.

ULC Subject C305-M1972  Panic Hardware  These Requirements cover releasing devices actuated by a crossbar for outward-opening doors, designed to facilitate the safe egress of persons from buildings in the event of panic or other emergency. These Requirements do not pertain to the fire-retardant classification of a door and releasing-device assembly.

21.060 91.060.50 

Check Valves for Fire Protection Service

These requirements cover check valves of NPS 1 and larger sizes, used in piping systems supplying water for fire protection service. The check valves covered by these requirements are intended for installation and use in accordance with the Standards for:a) Low-, Medium-, and High-Expansion Foam, NFPA 11;b) Installation of Sprinkler Systems, NFPA 13;c) Installation of Standpipe and Hose Systems, NFPA 14;d) Water Spray Fixed Systems for Fire Protection, NFPA 15;e) Installation of Foam-Water Sprinkler and Foam-Water Spray Systems, NFPA 16;f) Installation of Stationary Pumps for Fire Protection, NFPA 20;g) Water Tanks for Private Fire Protection, NFPA 22; andh) Installation of Private Fire Service Mains and Their Appurtenances, NFPA 24. Check valves covered by these requirements are intended for installation and use in accordance with, but not limited to the National Fire Code of Canada (NFC), and the National Building Code of Canada (NBC)..

13.220.20 23.060.50 

These requirements cover pipeline strainers for fire protection service. These devices are intended for use in fire service systems such as sprinkler systems installed in accordance with the Standard for the Installation of Sprinkler Systems, NFPA 13, and fixed water spray systems installed in accordance with the Standard for WaterSpray Fixed Systems for Fire Protection, NFPA 15, where protection against clogging of water discharge is needed.

ULC Subject C331-1975  Guide for the Investigation of Strainers for Flammable Fluids and Anhydrous Ammonia

These requirements cover complete self-contained strainer or filter assemblies intended for use with designated flammable fluids and anhydrous ammonia (fertilizer grade) in residential and commercial fuel burning, dispensing, and handling facilities. Although these devices are designated "strainers", they may be either strainers or filters according to the common terminology of the industry.

71.040.20 75.200 

ULC Subject C343-1975  Guide for the Investigation of Pumps for Oil-Burning Appliances

These requirements cover pumps that are intended to be used as part of oil-burning appliances or installed in fuel-oil piping systems serving such equipment. Oil-burning appliance pumps are classified as eitherautomatic or power-operated.

23.080 27.060.10 

 ULC Subject C352-1975  Guide for the Investigation of Constant-Level Oil Valves

These requirements cover constant-level oil valves that are intended to be used in fuel-oil handling or burning equipment. They also apply to constant-level valves intended for use at or near a supply tank to maintain a constant head of oil for gravity feed to burner equipment requiring uniform oil pressure to be maintained in its supply line.

23.060 75.200 

ULC/ORD-C376-1995  Fire Growth of Foamed Plastic Insulated Building Panels in a Full-Sale Room Configuration

This document describes the test method used to determine the contribution to fire growthprovided by a thermoset or thermoplastic foamed plastic insulated building panel using a specified ignition source.

13.220.40 19.020

83.080.20 

Guide for the Investigation of Draft Equipment

These requirements apply to the design and construction of draft equipment intended to assist in maintaining the desired combustion chamber draft in heating appliances. Draft equipment classifications include draft regulators, automatic damper controls, and draft fans for inducing draft.

27.060.10 

13.220.20 13.320 

ULC/ORD-C393-1995  Indicating Pressure Gauges for Fire Protection Service

These requirements cover indicating pressure gauges of the elastic element type for use with sprinkler or standpipe equipment for fire protection service. The nominal sizes of gauges covered by these Requirements are 90 and 115 mm. The gauges covered by these Requirements are primarily intended for installation and use in accordance with the Standards for: Installation of Sprinkler Systems, NFPA 13; Installation of Standpipe and Hose Systems, NFPA 14; and Installation of Private Fire Service Mains and Their Appurtenances, NFPA 24.

13.220.20 23.060.40 

ULC Subject C395-1975  Guide for the Investigation of Automotive Fuel Tanks

These requirements cover fuel tanks which may be mounted outside the frame or in other exposed locations on gasoline or diesel engine powered trucks, tractors, or trailers.

23.020.20 

ULC Subject C404-1974  Guide for the Investigation of Gauges, Indicating Pressure for Compressed Gas Service

These requirements cover indicating pressure gauges of the elastic element type usually employed in the high-pressure side of regulators or reducing valves used on compressed gas containers or cylinders of oxygen, hydrogen, nitrogen, and other gases. Such gauges usually have pressure ranges of 0 - 1500, 0 -2000, 0 - 3000, or 0 - 4000 pounds per square inch (psi).

17.100 23.020.30 

ULC Subject C407-1974  Guide for the Investigation of High Pressure Gas Manifolds

These requirements cover equipment for manifolding high-pressure gas cylinders to supply gas for various industrial and commercial applications.

23.020.30 23.060 

ULC Subject C410-1962  Guide for the Investigation of Floor Coating and Finishing Materials

This document is a guide for the Investigation of Floor Coating and Finishing Materials for friction characteristics and additionally, fire resistance for oil and grease absorbents..

91.060.30 

Absorbents for Flammable and Combustible Liquids

These requirements cover products intended to be used to absorb leaked or spilled flammable or combustible liquids to reduce the fire hazard from the exposed products and to assist in their disposal.

These requirements are intended to cover the investigation of pellet vents for use in residential dwellings for theventing to the outdoors of the products of combustion from certified automatic wood or corn pellet fuelledappliances.

91.140.30 

ULC/ORD-C441.3-1998  These requirements cover gas vent connectors intended for use with gas-fired appliances equipped with draft hoods that produce flue gas temperatures not exceeding 245°C.

27.060.20 91.140.30 

Page 33: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 33 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$110.00

ULC/ORD-C448A-1979 $110.00

NA $110.00

ULC/ORD-C501-01 NA $110.00

$110.00

Flexible Metallic Hose $110.00

$110.00

$110.00

$110.00

$110.00

$110.00

$110.00

$110.00

$110.00

$110.00

$110.00

$110.00

NA $110.00

$110.00

ULC Subject C448-1979  Guide for the Investigation of Pumps for Fire Protection Service

These requirements apply to horizontal split case, end suction, vertical inline and turbine type centrifugal pumps for use in water supply systems for fire-protection service.

13.220.20 23.100.10 

Guide for the Investigation of Diesel Engines for Driving Centrifugal Fire Pumps

These requirements cover the design, construction and performance of diesel engines intended for driving centrifugal fire pumps.

Engines meeting these requirements are capable of being installed in accordance with the Standard of the National Fire Protection Association for the Installation of Centrifugal Fire Pumps, NFPA 20.

13.220.30 27.020 

ULC/ORD-C488-1995  Remote Burglar Alarm Signalling Centres

This ORD covers requirements applicable to remote burglar alarm signalling centres such as satellite centres, signal processing centres and bridging centres.

Signals received from Residential, Commercial and Financial burglar alarm systems may be transmitted directly to a central or monitoring station or by way of a satellite centre and/or a signal processing centre and/or a bridging centre.

Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials

This Document describes the test method used to determine the adhesion qualities and fire hazard of adhesives used in heating and cooling appliances to secure insulation.

ULC Subject C525-1975  Guide for the Investigation of Flame Arresters for Use on Vents of Storage Tanks for Petroleum Oil and Gasoline

These requirements cover flame arresters for use in open vent pipes, flame arresters for use with vent valves, and combination flame arrester-vent valves, all intended for use on vents of storage tanks for petroleum oil and gasoline. These requirements also cover flame arresters for oil tanker ships.

13.220 

ULC/ORD-C536-1998  These requirements cover flexible metallic hoses having nominal inside diameters of not more than 100 mm intended for use in piping systems carrying designated liquefied and compressed gases, including anhy- drous ammonia, and flammable and combustible liquids, at pressures not exceeding 3450 kPa and temper- atures not greater than 230°C nor lower than minus 40°C. These requirements do not apply to gas appliance connectors for handling fuel gases at 35 kPa or less nor to metallic hose intended for use in oil transportation, petroleum refinery, or gas transmission and distribution piping systems.

23.040.70 

ULC Subject C539-1973  Guide for the Investigation of Fire Alarm Devices, Single and Multiple Station, Mechanically-Operated Type

These requirements cover heat actuated mechanically operated single- and multiple-station fire alarm devices intended for indoor installation in accordance with the Standard for Household Fire Warning Systems, NFPA No. 74. The requirements do not cover electrically operated single- or multiple-station fire alarm devices actuated by heat, smoke, or combustion products.

13.220.20 13.320 

ULC Subject C558-1975  Guide for the Investigation of Internal Combustion Engine-Powerd Industrial Trucks

These requirements cover the fire-hazard aspects of industrial trucks with internal-combustion engines, such astractors, platform-lift trucks, fork-lift trucks, and other specialized vehicles for industrial use. These requirements do not cover other possible hazard aspects of such equipment.1.2These requirements do not cover farm or road vehicles or automotive vehicles for highway use.

53.060 

ULC Subject C565-1975  Guide for the Investigation of Liquid Level Gauges and Indicators for Anhydrous Ammonia and LP-Gas

These requirements cover liquid-level gauges and indicators for anhydrous ammonia and liquefied petroleum gas (LP-Gas) for use with pressure vessels in non-refrigerated systems in installations covered by the following Standards: ANSI K61.1, Storage and Handling of Anhydrous Ammonia; ANSI Z106.1, Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58); NFPA No. 59, Storage and Handling of Liquefied Petroleum Gases at Utility Plants

17.040 

ULC Subject C567-1974  Guide for the Investigation of Pipe Connectors for Flammable Liquids and LP-Gas

These requirements cover swivel connectors, pipe-connecting fittings of the threadless compression type, and hose-pipe connectors. The guide covers connectors and fittings used in specific services.

23.040.60 

ULC Subject C583-1974  Guide for the Investigation of Electric Battery Powered Industrial Trucks

These requirements cover the fire-, electric-shock, and explosion-hazard aspects of electric battery powered industrial trucks such as tractors, platform-lift trucks, fork-lift trucks, and other specialized vehicles for industrial use. These requirements do not cover other possible hazard aspects of such equipment.

53.060 

ULC Subject C634-M1986  Guide for the Investigation of Connectors and Switches for Use with Burglar Alarm Systems

These requirements cover connectors and switches for use with burglar-alarm systems in mercantile premises, mercantile safes and vaults, bank safes and vaults, and residences.

13.32019.080

29.120.2029.120.40

97.180 

ULC Subject C644-1975  Guide for the Investigation of Container Assemblies for LP Gas

These requirements cover aboveground, underground, and interchangeable (aboveground or underground) stationary container assemblies for liquefied-petroleum gases which consist essentially of any of the following hydrocarbons or mixtures of them: propane, propylene, butanes (normal butane or isobutane), and butylenes. These container assemblies are provided with tanks constructed under the appropriate provisions of the Code for the Construction and Inspection of Boilers and Pressure Vessels, CSA B51.

23.020.10 

ULC Subject C644A-1980  Preliminary Standard for Propane Components, Automotive Type

These requirements cover the construction and test requirements of propane fuel system components for use on or for the conversion of automotive type equipment. These requirements do not cover propane components for use in stationary or nonautomotive applications

75.160.30 

ULC Subject C668-1975  Guide for the Investigation of Hose Valves for Fire-Protection Service

These Requirements cover the design and construction of angle-pattern and straightway-pattern hose valves ntended for use on standpipes, fire pumps, and hydrants supplying water for fire-protection service.

13.220.20 23.040.70

23.060 

ULC Subject C710-1980  Preliminary Standard for Grease Extractors for Exhaust Ducts

These requirements cover grease extractors for exhaust ducts intended for placement over restaurant-type cooking equipment, such as ranges, broilers, deep-fat fryers, grills, etc.

91.140.30 97.040.20 

ULC/ORD-C719(S)-1998  Requirements for the Investigation of Stapler Installed Non-Metallic Sheathed Cable Staples

These requirements cover non-metallic sheathed cable staples intended to be installed by means of a stapler and employed in accordance with the requirements of the Canadian Electrical Code, Part I.

21.060.70 

ULC Subject C752A-1975  Guide for the Investigation of Bullet-Resisting Glazing Material 

These requirements cover materials, devices, and fixtures used to form bullet-resisting barriers designed to protect against robbery or holdup. Electrically operated equipment such as teller's fixtures using electrically driven deal trays or package passers, intercommunication, and other electrical equipment are also examined and tested with respect to fire, casualty, and shock hazards in addition to the equipment's bullet-resisting properties.

ULC Subject C753-M1986  Guide for the Investigation of Alarm Accessories for Automatic Water-Supply Control Valves for Fire Protection Services

These requirements cover alarm accessories for automatic water supply control valves for use in automatic sprinkler equipment for fire-protection service. Accessories may include water motors and gongs, pressure-operated switches, and other electrical and non electrical attachments, components, or units commonly used with alarm, dry-pipe, deluge and pre-action valves.

13.220.2013.32019.080

91.140.60 

Page 34: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 34 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

$110.00

$110.00

Roof Drains $110.00

$110.00

These requirements cover Printed-Wiring Boards that are intended for use in electric equipment $110.00

$110.00

$110.00

ULC/ORD-C887-00 Timelocks NA $110.00

Teller’s Lockers $110.00

$110.00

ULC/ORD-C924-02 NA $110.00

$110.00

75.2 $140.00

ULC Subject C779-1975  Guide for the Investigation of Electrically Conductive Floorings

These requirements cover electrically conductive floorings of the completed or finished type intended for use inindustrial plants, hospital operating rooms, and similar locations where it is necessary for safety to avoid the accumulation of static electricity. These requirements do not cover electrically conductive equipment and materials for use in flammable anaesthetizing locations.

13.100 91.060.30

91.180 

ULC Subject C789-1975  Indicator Posts for Fire Protection Service

These requirements cover indicator posts, including wall and underground types, for use in operating valves of the inside-screw pattern and for indicating the position of the gates in such valves. Indicator posts are primarilyintended for use with valves controlling water supplies to automatic sprinkler equipment, standpipes, etc., used in private fire service where connections enter buildings.

13.220.20 

ULC/ORD-C790.4-1996  These requirements cover combustible and noncombustible roof drains and strainer domes for use in new and retrofit roof construction.

91.060.20 

ULC Subject C793  Guide for the Investigation of Automatically Operated Smoke and Heat Roof Vents

This guide provides guidance covering design and construction, practicality, durability, reliability of operation and uniformity of Automaticallly Operated Smoke and Heat Roof Vents. It is a guide only and is not intended as a complete or final set of specifcations to determine etiher acceptance or the manufacturers development of his product.

91.140.30 

ULC Subject C796-1974  Guide for the Investigation of Printed-Wiring Boards

31.180 

ULC Subject C822-M1982  Guide for the Listing and Labelling of Fire Department Pumpers

This Guide describes the method by which Underwriters' Laboratorires of Canada, (ULC), conducts the initial investigation of a pumper manufacturer's fabrication and testing facitities and the procedure subsequently followed by ULC in conducting routine performance tests at the factory on fire department pumpers intended to bear ULC label. The complete investigation and performance test programme outlined herein is based on the Standard for Automobile Fire Fighting Apparatus (ULC-S515-M1981)

13.220.30 43.160 

ULC Subject C842-M1984  Guide for the Investigation of Valves for Flammable and Combustible Liquids

These requirements cover valves that are intended to be used for the control of flammable and combustible liquids. They are of the type commonly used in piping systems and in fuel burning equipment. Valves covered by this Guide are for use with liquids which are handled at temperatures within the range of -29°C to +52 °C. These requirements cover valves of the manually operated, pressure operated or temperature operated types, or combinations of such to the exclusion of types operated wholly or partially by electricity. They may form part of an assembly which provides for additional functions or service, the requirement for which are outside the scope of these requirements.

23.060 

These requirements cover time controlled locks intended for attachment on vault doors, on the doors of security containers, and the like, to provide a means for locking the door for a predetermined length of time as protection against burglary, robbery or coercive action, such as forcing combination or key holders to release their locks.

ULC Subject C901-1975  These requirements cover tellers' lockers intended for convenient deposit and storage under timelock of excess funds which might otherwise accumulate and be exposed openly on cashiers' or tellers' counters during an at- tempted robbery. Tellers' lockers may consist of a reserve cash compartment only, a combination cash drawer and reserve compartment in a single unit, or an assembly of these and other units necessary to the proper handling of funds during business hours.

03.060 13.310 

ULC Subject C904-M1987  Guide for the Investigation of Vehicle Alarm Systems and Units

These requirements cover construction and operation of vehicle alarm systems intended for use on motor trucks,trailers, and passenger cars, to protect against holdup, theft of contents, and with the exception of passenger cars, unauthorized movement of the vehicle.

13.310 43.040.20 

Photoluminescent and Self Luminous Exit Signs

These requirements cover emergency self-luminous exit signs and photoluminescent exit signs for use in ordinary locations. Such equipment is intended to provide self-luminous exit and or direction indicators in the event of failure of the normal supply or in the event of accident to elements of a system intendedto supply, distribute, and control power and illumination essential to safety of human life.

These requirements cover self-luminous and photoluminescent exit signs intended for installation as required by the authorities having jurisdiction.

These requirements do not cover unit equipment for emergency lighting which are investigated under CSA Standard C22.2 No. 141, Unit Equipment for Emergency Lighting, and electrically-operated exit signs which are investigated under CSA 860, Performance of Internally Lighted Exit Signs

These requirements do not cover low-level path marking and lighting systems. Such equipment is covered by UL 1994, Standard for Low Level Path Marking and Lighting Systems.

ULC/ORD-C959-1993  Chimneys, Industrial 540°C and 760°C

These are factory-built industrial chimneys intended for use with certain process equipment and large oil or gas burning building heating appliances normally producing flue gas temperatures of 540°C or 760°C, or less as applicable.

91.060.40 

ULC/ORD-C971-2005 Including Errata 1

Nonmetallic Underground Piping for Flammable and Combustible Liquids

These requirements cover primary carrier, secondary containment, integral primary/secondary containment, normal vent and vapour recovery, nonmetallic pipe, fittings, and systems (products) intended for use underground in the distribution of petroleum-base flammable and combustible liquids, alcohols, and alcohol-blended fuels as identified in this document. The products covered by these requirements are intended for installation and use in accordance with the regulations of the Authority Having Jurisdiction and the following documents: A) National Fire Code of Canada; B) CSA B139, Installation Code for Oil-Burning Equipment; and C) Environmental Code of Practice for Aboveground and Underground Storage Tank Systems Containing Petroleum and Allied Petroleum Products (CCME EPC-LST-61E).

These requirements cover nonmetallic thermoplastic (flexible) and thermoset (rigid) plastic piping with manufacturer-supplied fittings for underground use only. The products covered by this document have been evaluated for assembly in normal soil applications by qualified persons in accordance with the manufacturer’s instructions.   The products covered by this document have not been evaluated for applications in sumps [more than 305 mm (12 in) from sump wall], as connector pipe (between underground pipe and dispensing device), aboveground or marine use, or other applications exceeding ambient temperatures of 23°C (75°F).

Page 35: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 35 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C996.1-2000 NA $110.00

ULC/ORD-C996.2-01 Grease Interceptors NA $110.00

These requirements cover household burglar alarm system units intended for use in residences. $110.00

$110.00

ULC/ORD-C1058.5-2004 $140.00

ULC/ORD-C1058.5-2004 $140.00

Polyvinylidene Fluoride (PVDF) Corrosive Drainage Systems

These requirements cover polyvinylidene fluoride corrosive drainage system applications. Requirements for materials of construction, pipe and fittings are included. This Document is intended for the evaluation of corrosive drainage systems in Schedule 40 and 80 ISP, and SDR 21 pipe sizes.

These requirements cover shop fabricated grease interceptors intended to collect and separate organic grease and/or oil from water to the degree as determined by the requirements herein at an inlet concentration not exceeding 12 000 mg/L.

ULC Subject C1023-1974  Burglar Alarm System Units, Household

97.180 

ULC Subject C1037-M88  Guide for the Investigation of Anti-theft Alarms and Devices

These requirements apply to the construction, performance and operation of equipment intended to provide antitheft protection.

13.310 

Halon and Halocarbon Clean Agent Recovery and Reconditioning Equipment

These requirements cover the construction and performance of Halons 1301, 1211 and halocarbon clean agent recovery and reconditioning equipment intended for use in: A) recovering Halons 1301, 1211 or halocarbon clean agent from fire extinguishing system containers and removing contaminants; or B) recovering and transferring Halons 1301, 1211 or halocarbon clean agent from fire extinguishing system containers without removal of contaminants. The equipment is intended for indoor use in a commercial halon or halocarbon clean agent system servicing or reconditioning facility. These requirements cover (1) products intended for permanent connection to 600 V or lower potential circuits, and (2) products intended for cord connection to 300 V or lower potential circuits. The cord connection, where one is used, and the electrical components and system within the product shall comply with the CSA C22.1-02, Safety Standard for Electrical Installations, Canadian Electrical Code, Part I.

13.020 13.220.10 

Matériel de récupération et de remise en état des agents propres à l'halocarbure et au halon

Ces exigences couvrent la construction et le rendement du matériel de récupération et de remise en état des agents propres à l'halocarbure et du halon 1301 et 1211 conçu pour : A) récupérer le halon 1301, 1211 ou les agents propres à l'halocarbure des récipients des systèmes d'extinction d'incendie et en éliminer les contaminants; B) récupérer et transférer le halon 1301, 1211 ou les agents propres à l'halocarbure des récipients des systèmes d'extinction d'incendie sans éliminer les contaminants. Le matériel est conçu pour une utilisation intérieure dans une installation de remise en état ou d'entretien des agents propres à l'halocarbure. Ces exigences couvrent (1) les produits conçus pour un branchement continu à un circuit d'un potentiel de 600 V ou moins et (2) les produits conçus pour être branchés au moyen d'une rallonge à un circuit d'un potentiel de 300 V ou moins. La rallonge, s'il y a lieu, ainsi que les composants et le système électriques du produit doivent satisfaire à la Norme de sécurité relative aux installations électriques, Code canadien de l'électricité, partie I.

13.020 13.220.10 

Page 36: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 36 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C1058.18-2004 $140.00

ULC/ORD-C1058.18-2004 $140.00

$110.00

$110.00

$110.00

$110.00

ULC/ORD-C1258-03 13.220.20 $110.00

$110.00

ULC/ORD-C1474-03 13.220.20 $110.00

$110.00

NA $110.00

ULC/ORD-C1713-03 13.220.20 $110.00

ULC/ORD-C1767-03 13.220.20 $110.00

ULC/ORD-C2043-0 NA $110.00

The Servicing of Halon and Clean Agent Extinguishing Systems

These requirements apply to companies involved in the charging, recharging, maintenance, repair, inspection and decommissioning of halon and clean agent extinguishing systems and equipment, including the recovering and reconditioning of the halon and halocarbon clean agent. These requirements apply to the servicing of Halon 1301 and halocarbon clean agent systems. These requirements do not apply to the servicing of carbon dioxide systems or portable fire extinguishers. The servicing of Portable Fire Extinguishers is covered in the Standard for the Regulation of the Servicing of Portable Fire Extinguishers, CAN/ULC-S532.

03.080.10 13.220.10 

Entretien des systèmes d'extinction au halon et aux agents propres

Ces exigences s'appliquent aux entreprises du domaine du chargement, du rechargement, de l'entretien, de la réparation, de l'inspection et de la mise hors service du matériel et des systèmes d'extinction au halon et aux agents propres, y compris la récupération et la remise en état du halon et des agents propres à l'halocarbure. Ces exigences s'appliquent à l'entretien des systèmes au halon 1301 et aux agents propres à l'halocarbure. Ces exigences ne s'appliquent pas à l'entretien des systèmes d'extinction au dioxyde de carbone ni auxextincteurs portatifs. L'entretien des extincteurs portatifs est traité dans la publication Norme pour la réglement-ation de l'entretien des extincteurs portatifs, CAN/ULC-S532.

03.080.10 13.220.10 

ULC/ORD-C1076-M1986  Proprietary Burglar Alarm Units and Systems

These requirements apply to the construction, performance and operation of equipment intended for use in proprietary burglar alarm units and systems employed to protect against burglary.

13.310 

ULC Subject C1091-1974  Preliminary Standard for Butterfly Valves for Fire Protection Service

These requirements cover the design, construction and performance of butterfly valves for use in fire protection systems.

13.220.20 23.060 

ULC/ORD-C1254.6-1995  Fire Testing of Restaurant Cooking Area Fire Extinguishing System Units

These requirements cover the performance during fire tests of pre-engineered fire extinguishing system units intended for the protection of restaurant cooking areas.

13.220.10 13.220.40 

ULC/ORD-C1254.18-1995  The Servicing of Restaurant Cooking Area Extinguishing Systems 

These requirements apply to companies involved in the installing, recharging, maintenance, repair, inspection and decommissioning of restaurant cooking area extinguishing systems and equipment.1.2 These requirements apply to the servicing of wet chemical and dry chemical systems.

03.080.10 13.220.10 

Piping and Couplings, Polyvinyl Chloride (PVC) for Underground Fire Service

This document specifies requirements for polyvinyl chloride (PVC) pressure pipe, couplings, and gaskets for use in underground, nonpotable fire service systems and connections to such systems. The pipe is either the distribution or transmission type.Distribution pipe covered by these requirements and Class/Pressure rated 100, 150, and 200 for working pressures of 690, 1030 and 1380 kPa, respectively, and has a nominal inside diameter of 100 to 300 mm. Transmission pipe covered by these requirements and Class/Pressure rated 100, 125, 160, 165, 200 and 235 for working pressires of 690, 860, 1100, 1140, 1380 and 1620 kPa, respectively, and has a nominal inside diameter of 350 to 900 mm.  

ULC Subject C1275-1984  Guide for the Investigation of Storage Cabinets for Flammable Liquid

These requirements cover storage cabinets for flammable liquid containers which are intended for the storage of flammable liquid and permitted by the relevant sections of the National Fire Code of Canada.

23.020.01 

Adjustable Drop Nipples for Sprinkler Systems

This standard covers adjustable pipe nipples intended for use with sprinklers to permit adjustment of the distance of the sprinkler from the sprinkler system branch line.

ULC/ORD-C1482-M1990  Space Heaters for Use With Particulate Solid Fuels 

These requirements are intended to cover the investigation of automatically fuelled heaters burning particulate solid fuels.

91.140.20 

ULC/ORD-C1703 -01 Flat Plate Photovoltaic Modules and Panels

These requirements cover flat-plate photovoltaic modules and panels intended for installation on or integral with buildings, or to be free-standing (that is, not attached to buildings), in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1, and the National Building Code of Canada.These requirements cover modules and panels intended for use in systems with a maximum system voltage of 1000 V or less.These requirements also cover components intended to provide electrical connection to and mounting facilities for flat-plate photovoltaic modules and panels. These requirements do not cover:

A Equipment intended to accept the electrical output from the array, such as power conditioning units (inverters) and batteries;B Any tracking mechanism;C Cell assemblies intended to operate under concentrated sunlight;D Optical concentrators; orE Combination photovoltaic-thermal modules or panels.

Pressure Pipe and Couplings, Glass Fiber-Reinforced, for Underground Fire Service

These requirements cover glass-fiber-reinforced, thermosetting-resin pipe (RTRP) and glass-fiber-reinforced, plastic-mortar pipe (RPMP), and their couplings. The pipe is for use in underground fire service systems and connections to such systems.Pipe covered by these requirements is designated as Class 100, 150, 200, 250, or greater for rated working pressures of 690, 1030, 1380 and 1720 kPa or higher, respectively, and has a nominal inside diameter of 100 to 1500 mm.  

Early Suppression Fast-Response Sprinklers

These requirements cover early suppression fast response (ESFR) sprinklers intended for installation as part of sprinkler systems for fire-protection service. Requirements for installation and use of ESFR sprinklers are included in the Standard for the Installation of Sprinkler Systems, NFPA 13  

Fire Test for Smoke and Visible Heat Release for Discrete Products and their Accessories Installed in Air-Handling Spaces

This is a fire test method for determining the fire performance response of discrete products (electrical equipment) intended to be installed in air handling spaces, such as above suspended ceilings. These products are subjected to an open flame ignition source and evaluated using a product calorimeter. The purpose of this test is to determine the rate of heat release and the rate of smoke release of the burning product samples as they relate to the requirements for fire-resistant and low-smoke-producing characteristics in accordance with the provisions of the Canadian Electrical Code.

This test method does not provide information on the performance of products in other fire or test conditions. This test does not investigate the toxicity of the products of combustion.

This test does not cover the constructional, electrical, or other performance requirements of the product.

Page 37: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 37 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

ULC/ORD-C2024-02 NA $110.00

ULC/ORD-C2351-03 13.220.20 $110.00

Fire Tests for Optical Fibre Cable Raceway

These requirements cover the following types of optical fibre cable raceways (OFCR) and fittings designed for use with optical fibre cables in accordance with CSA 22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part I:

A Plenum – Evaluated for installation in buildings required to be of noncombustible construction, in situations where raceways penetrate fire separations and in ducts, plenums, or other spaces used for environmental air in accordance with CSA 22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part I, and the National Building Code of Canada as well as for riser and general use applications.

B Riser – Evaluated for installation in buildings required to be of noncombustible construction and in locations where raceways penetrate fire separations in accordance with CSA 22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part I, and the National Building Code of Canada as well as for general use applications.

C General Use – Evaluated for installation in buildings permitted to be of combustible construction in the National Building Code of Canada, except for plenums and where raceways penetrate fire separations.

Spray Nozzles for Fire-Protection Service

These requirements cover automatic and non-automatic (open) type water spray nozzles for installation inaccordance with the Standard for Installation of Sprinkler Systems, NFPA 13, and the Standard for Water Spray Fixed Systems for Fire Protection, NFPA 15. Nozzles are categorized by the discharge coefficient "Km" of the orifice, water discharge angle or pattern, type of coating or plating, and other factors that have a bearing on their application. Automatic nozzles are also categorized by operating temperature rating.

Page 38: 2006 Ulc Publications Catalogue Wb Canada-Eng

Page 38 of 40

ULC STANDARD NO. TITLE ABSTRACT ICS CODE PRICE (CDN)

CATALOGUE OF ULC STANDARDS, SPECIAL PUBLICATIONS AND OTHER RECOGNIZED DOCUMENTS

CATALOGUE DES NORMES ULC, DES PUBLICATIONS SPECIALES ET DES AUTRES DOCUMENTS RECONNUS

FSRC 02 (2001) NA $110.00

LIST OF TECHNICAL SUPPLEMENTS/LISTE DES SUPPLÉMENTS TECHNIQUES

$80.00

IDR-PADS536-10-EN NA $15.00

IDR-PADS536-10-FR FICHE DE DISPOSITIF NA $15.00

IDR-PADS536-20-EN $25.00

IDR-PADS536-20-FR FICHE DE DISPOSITIF NA $25.00

IDR-PADS537-10-EN NA $15.00

IDR-PADS537-10-FR FICHE DU DISPOSITIF NA $15.00

IDR-PADS537-20-EN NA $25.00

IDR-PADS537-20-FR FICHE DU DISPOSITIF NA $25.00

RPT-TIS536-EN NA $18.00

RPT-TIS536-FR NA $18.00

RPT-SVS537-EN NA $20.00

RPT-SVS537-FR NA $20.00

LIST OF SPECIAL PUBLICATIONS/LISTE DES PUBLICATIONS SPÉCIALESFIRE SERVICE RESEARCH COMMITTEE/COMITÉ DE RECHERCHE SUR LES SERVICES D'INCENDIE

Fire Risk Analysis Rating System (BOOK AND CD)

Provides pertinent information to the protector and the protected as a means of enhancing safety from fire in individual properties. It is not intended as a means of assessing community fire safety as a whole.

The further purpose of this rating system is to assist you in analyzing fire risk factors and fire protection requirements for particular buildings with a high degree of objectivity that yields a numerical rating, and where shortcomings are observed, to identify means of counterbalancing the deficiencies. It is not intended to serve as a means of waiving compliance with applicable codes, statutes or regulations, nor provide a definitive analysis of the fire hazard of a particular building beyond that which is provided for through an assessment against existing codes, statutes or regulations.

ULC-S601(A) - 2001ULC-S603(A) - 2001ULC-S615(A) - 2002ULC-S630(A) - 2001

TechnicalSupplements forthe Refurbishing of Underground andAboveground Tanks

The following procedures have been developed in response to a request for an acceptable routine for the refurbishing of:a) ULC-S603(A) steel underground tanks for flammable and combustible liquids which have been disinterred and are intended for relocation. b) ULC-S615(A) reinforced plastic underground tanks for flammable liquids, which have been disinterred and are intended for relocation and The following procedures have been developed in response to a request for an acceptable method of refurbishing: c) ULC-S601(A) steel aboveground horizontal tanks for flammable and combustible liquids andd) ULC-S630(A) steel aboveground vertical tanks for flammable and combustible liquids.

The use of refurbished tanks shall be subject to the approval of the authority having jurisdiction

23.020.10 75.200

INDIVIDUAL DEVICE RECORD

3 Part carbonless forms - Pack of 10 - Individual Device record sheets for (25 per page) for the Annual Fire Alarm System verification reports as per CAN/ULC-S536-04 Clause 5.7.1.3, E3.1.

Formulaires autocopiants à triple exemplaire – paquet de 10 – fiches du dispositif (25 par page) pour les rapports de vérification annuelle du réseau avertisseur d'incendie conformément à la norme CAN/ULC-S536-04, article 5.7.1.3, annexe E3.1.

INDIVIDUAL DEVICE RECORD

3-Part carbonless forms - Pack of 20 - Individual Device record sheets for (25 per page) for the Annual Fire Alarm System verification reports as per CAN/ULC-S536-04 Clause 5.7.1.3, E3.1.

Formulaires autocopiants à triple exemplaire – paquet de 20 – fiches du dispositif (25 par page) pour les rapports de vérification annuelle du réseau avertisseur d'incendie conformément à la norme CAN/ULC-S536-04, article 5.7.1.3, annexe E3.1.

INDIVIDUAL DEVICE RECORD

3 Part carbonless forms - Pack of 10 - Individual Device records sheets (25 per page) for CAN/ULC-S537-04 Verfication of Fire Alarm System per Appendix C6.1.

Formulaires autocopiants à triple exemplaire – paquet de 10 – fiches du dispositif (25 par page)pour la norme CAN/ULC-S537-04 Vérification du réseau avertisseur d'incendie conformément à l'annexe C6.1.

INDIVIDUAL DEVICE RECORD

3 Part carbonless forms - Pack of 20 - Individual Device records sheets (25 per page) for CAN/ULC-S537-04 Verfication of Fire Alarm System per Appendix C6.1

Formulaires autocopiants à triple exemplaire – paquet de 20 – fiches du dispositif (25 par page)pour la norme CAN/ULC-S537-04 Vérification du réseau avertisseur d'incendie conformément à l'annexe C6.1.

FIRE ALARM SYSTEM ANNUAL TEST & INPECTION REPORT

3-Part carbonless forms - Full report (14 pages) for Annual Fire Alarm System verification reports. Clause 5.1.2 of CAN/ULC-S536-04 requires annual inspections and tests of the Fire Alarm System along with a documented report. These carbonless forms are based on and conform to the requirements of CAN/ULC-S536 Appendix E.

FICHE D'INPECTION ET D'ESSAI ANNUALS DU RESEAU

Formulaires autocopiants à triple exemplaire – rapport intégral (14 pages) pour les rapports de vérification annuelle du réseau avertisseur d'incendie. La sous-section 5.1.2 de la norme CAN/ULC-S536-04 exige que le réseau avertisseur d'incendie soit soumis à des inspections et à des essais annuels et que ceux-ci soient documentés dans un rapport. Ces formulaires autocopiants reposent sur les exigences de l'annexe E de la norme CAN/ULC-S536 et sont conformes à celles-ci.

FIRE ALARM SYSTEM VERIFICATION REPORTS

3 Part carbonless forms - Full report (14 pages) as required by CAN/ULC-S537-04verifying that the fire alarm system is installed in conformance with the design and CAN/ULCS524, Standard for the Installation of Fire Alarm Systems, and performs all of its intended functions as designed.The report conforms to the require-ments of Clauses 3.1.6, 3.1.7 and 3.2.2 of CAN/ULC-S537-04.

RAPPORTS DE VERIFICATION DU RESEAU ADVERTISSEUR

Formulaires autocopiants à triple exemplaire – rapport intégral (14 pages) requis en vertu de la norme CAN/ULC-S537-04 permettant de vérifier que le réseau avertisseur d'incendie est installé conformément aux exigences de la conception et de la norme CAN/ULC-S524, Norme sur l'installation des réseaux avertisseurs d'incendie et que toutes les fonctions prévues de ces réseaux sont exécutées conformément à la conception. Le rapport est conforme aux exigences des sous-sections 3.1.6, 3.1.7 et 3.2.2. de la norme CAN/ULC-S537-04.

Page 39: 2006 Ulc Publications Catalogue Wb Canada-Eng

SALES POLICY

ORDERS:

ULC Standards and ORDs are available through the ULC On-line store sitehttp://www.ulc.ca . If the standard or ORD you want is available on-line your bill andshipment will come from Gilmore Global Logistics. If the standard or ORD you wantis not available through the on-line store you will need to place your order bysending or bringing in an order form with your payment (credit card or Cheque). Theaddress for these orders is:

UNDERWRITERS’ LABORATORIES OF CANADA

Attn: Publications Department7 Underwriters RoadToronto, ONM1R 3B4

TEL: (416) 757-3611 Extension 61744FAX: (416) 757-9540E-mail: [email protected]

Canadian orders are subject to GST. ADD QST to all Quebec orders. Add HST to all New Brunswick, Newfoundland and Nova Scotia orders.

All orders are subject to shipping and handling charges. In addition for orders placed through ULC the following schedule applies:

Canada U.S.A. Other Countries

$12.00/copy $14.00/copy $16.00/copy

For orders placed through our web site you will be offered shipping via Federal Express or UPS.

All orders placed through the ULC On-line store are payable by credit card. All orders placed through ULC must be paid bycash, cheque, money order, Visa or Master Card. Cheques or Money Orders are to be made payable to Underwriters’Laboratories of Canada.

RETURNS: No returns will be accepted. All sales are final.

NOTE: ALL PRICES SUBJECT TO CHANGE WITHOUT NOTICE.

Page 40: 2006 Ulc Publications Catalogue Wb Canada-Eng

MODALITÉS D'ACHAT

COMMANDES:

Les normes et les ordonnances d'ULC seront offertes dans le magasin en ligne d'ULC àl'adresse suivante : http://www.ulc.ca. Si la norme ou l'ordonnance que vousrecherchez est disponible en ligne, votre commande et facture proviendront de GilmoreGlobal Logistics. Si elles ne sont pas disponibles en ligne, vous devrez faire parvenirou présenter un bon de commande accompagné du paiement (carte de crédit ouchèque) à l'adresse suivante :

LABORATOIRE DES ASSUREURS DU CANADA

À l'attention du service des publications7, chemin UnderwritersToronto (Ontario)M1R 3B4

Téléphone : (416) 757-3611 poste 61744Télécopieur : (416) 757-9540Courriel: [email protected]

Les commandes canadiennes sont assujetties à la TPS. AJOUTER la TVQ aux commandes du Québec.Ajouter la TVH aux commandes du Nouveau-Brunswick, de Terre-Neuve et de la Nouvelle-Écosse.

Des frais de port et de manutention seront rajoutés à toutes les commandes. De plus, voici la liste des prix pour les commandes passées au bureau d'ULC :

Canada É.-U. Autres pays

12 $/exemplaire 14 $/exemplaire 16 $/exemplaire

Les commandes passées par l'entremise du site Web seront expédiées par Federal Express et UPS.

Toutes les commandes passées au bureau d'ULC doivent être payées au comptant, par carte de crédit. Toutes les commandespassées par le magasin en ligne d'ULC doivent être payées au comptant, par chèque, par mandat-poste, par Visa ou MasterCard.Tout chèque ou mandat-poste doit être fait à l'ordre des Laboratoires des assureurs du Canada.

RETOUR DE MARCHANDISES : Aucun retour ne sera accepté. Toutes les ventes sont finales.

NOTA : LES PRIX PEUVENT CHANGER SANS PRÉAVIS.

DROITS D'AUTEUR. AUCUNE REPRODUCTION EN ENTIER OU EN PARTIE, PAR UN MOYEN QUELCONQUE, DENORMES ULC, DE DOCUMENTS RECONNUS OU DE TOUTE AUTRE PUBLICATION N'EST PERMISE SANS