2012 Medeco Catalog
ASSA ABLOY, the global leader indoor opening solutions
Table of contents
Software, Services & KeysServices & Sales Tools .................................................. 16Software & Support...................................................... 19Keys..................................................................................... 20eKeys .................................................................................. 22
Nexgen XTNexgen XT Retrofit Cylinders.................................... 30Nexgen XT Cam Style Locks....................................... 33Nexgen XT Keys, Software & Support .................... 34
Vertical LogicVertical Logic Retrofit Cylinders............................... 36Vertical Logic Support Tools...................................... 40
Classic LogicClassic Logic Retrofit Cylinders................................. 42Classic Logic Deadbolts/Cylinders........................... 46Classic Logic Cam Style Locks ................................... 47Classic Logic Support ................................................... 48
Retrofit CylinderMortise Cylinders .......................................................... 50Rim Cylinders .................................................................. 59Lever & Knob Cylinders ............................................... 62Deadbolt Cylinders ....................................................... 76Padlock Cylinders .......................................................... 81Interchangeable Core ................................................. 87International Cylinders................................................ 99
Auxiliary LocksDeadbolts.......................................................................121Residential .....................................................................134Padlocks ..........................................................................142
Cam Style LocksCam Style Locks ..........................................................158Switch Locks + Components...................................166
Components, Tools, Key MachinesComponents .................................................................168Tools and Key Machines ............................................172
Key Control
Medecos Approach
The security of any locking system is dependent upon two
very important factors. The first of these is protection against
attacks such as picking, drilling, bumping and forcing. The
second is the ability to control duplication of existing keys.
Historically, unauthorized key duplication has played a major
role in compromising even the most sophisticated security
systems. Anyone with even temporary access to original keys
has no problem getting duplicates made for their own use if
the keys and key blanks are not patent protected. Even
stamping Do Not Duplicate on a key merely warns someone
not to copy the key it is not a promise of legal protection
or enforcement. The only way to ensure that keys cannot be
copied without the consent of the owner is a key system with
patent protected keys.
Medeco has counteracted the key control problem by doing three things:
1. Medeco manufactures cylinders which use keys that must
be made on special key cutting machines. These machines
are capable of reproducing the angled cuts and critical
tolerances necessary to produce a workable Medeco key,
and are not found at general hardware stores.
2. Medeco sells its high quality, precision machined cylinders
and locks only to security industry professionals. Every
restricted Medeco key blank is custom coined and tracked
by Medeco to identify it as an authorized key blank which
protects against unauthorized copies.
3. Medeco invests heavily in research and development to
establish strong patents and legal agreements to protect
its locks and key blanks from unauthorized distribution or
manufacture. In this way, Medeco can litigate to protect its
rights and the security of its customers.
A Key Control Program Thats Right for You
Not every user has the same key control needs. Thats why
Medeco has designed different key control programs and
different keyways to meet a wide range of security
specifications and key access requirements.
Dealer/Service CenterThis program offers instant local access to
additional keys with protection from unauthorized
copying. Consumers simply return to the security provider
from which they purchased the locks. This security profes-
sional will have a signature card on file completed by the
owner of the key system at the time the system was installed.
Card ProgramsAuthorized individuals are issued a card with
embossed control data and a space for their
signature. To obtain key duplicates, card holders present
the card to any participating Medeco security professional.
The data and signature will be verified and a key can then be
issued. A card program is ideal for residential or businesses
that need keys available nationwide.
End User ProgramThe End User program is for large facilities that
have their own locksmith on staff and that want to
produce Medeco keys themselves. This program offers
individualized control over key duplication procedures.
Commercial ProgramThe Commercial Program is designed for users who
use Medeco locks primarily for protection against
picking, drilling and other forms of physical attack. Keys may
be obtained from any Medeco locksmith without specific
authorization.
Factory ProgramAdditional keys are only available from the Medeco
factory and only with the proper signature.
ElectroMechanical SystemsElectromechanical systems allow the end user the
ability to control their own system to electronically
change access to any cylinder or key onsite and obtain audit
information.
Visit our website at www.medeco.com for more information
on all key programs.
5
= Medeco3 patent expiration date: 2021.
= Biaxial patent expiration date: 2005. Upgrading to Medeco3 recommended.
= Original patent expiration date: 1985. Upgrading to Medeco3 recommended.
= Permission for copying keys is obtained by presenting a signed authorization card, which is matched to proper identification.
= Permission for copying keys is provided by identification and signature verification, which must be presented to either theoriginal locksmith provider or the facility manager.
= Keys can be cut on-site by dealers or end-users that are contracted to participate in the respective key program.
= Keys are ordered locally and cut at a regional service center and then shippedback to the dealer.
= Keys are cut at the Medeco factory and shipped to dealer. Authorization is provided by signature verification.
= Medeco recommended high securityUL 437 Listed, ultimate Grade 1 strength, and A156.5-2001 and A156.30 Level A Certified.
ORG
BIA
M3
MEDECO3 IS RECOMMENDED BY SECURITY PROFESSIONALS AS THE LEADER IN HIGH SECURITY AND PATENTED KEY CONTROL.
M3
PAT.NO. 6,477,875
R
DO NOT DUPL CATE
RESTR CTED
PAT.NO. 6,477,875
R
PAT.NO. 6,477,875
RRESTRICTED
DO NOT DUPLICATE
R
AS
SO
CIA
TE
D
PAT. NO. 6,477,875
OF AMERICA
LO
CK
SM
ITH
S
M3
PAT. NO. 6,477,875
DO NOT DUPL CATE
RESTR CTED
R
PAT. NO. 6,477,875
CTEDRESTR
CATEDO NOT DUPL
R
M3
PAT. NO. 6,477,875
TM
MC
R
R
PAT. NO. 6,477,875
M3
SECUR TY LOCKS
PAT.NO. 6,477,875
R
R
6,4
77
,87
5
PA
T. N
O.
M3
SECUR1TY LOCKS
PAT.NO. 6,477,875
RESTRICTED
DO NOT DUPLICATE
R
SECUR TY LOCKS
PAT.NO. 6,477,875
DO NOT DUPLICATE
RESTRICTED
R
M3 DEALER FREEDOM / GOTHAM
DND / NYC M3 END-USER
M3 FACTORY RESTRICTED
MEDECO KEY CONTROL PROGRAM REFERENCE CHART
6
BIA
BIAXIAL DEALER GOLD (GLD) / PLATINUM (NUK)
PATRIOT / LIBERTY BIAXIAL END-USER
BIAXIAL FACTORY RESTRICTED
BIA
BIABIA
BIA
R
PAT. NO. 4,635,455
DO NOT DUPLICATE
RESTRICTED
R
R
PAT. NO. 4,635,455
DO NOT DUPLICATE
RESTRICTED
R
R
PAT. NO. 4,635,455
OF AMERICA
LO
CK
SM
ITH
S
AS
SO
C IA
TE
D
R
PAT. NO. 4,635,455
R
RESTRICTEDDO NOT DUPLICATE
R
R
R
DO NOT DUPLICATERESTRICTED
PAT. NO. 1,273,810PAT. NO. 4,635,455
DO NOT DUPLICATE
RESTRICTED
R
R
BIAXIAL KEYS
ORIGINAL KEYS
ORIGINAL DEALER SKY
ORIGINAL END-USER ORIGINAL FACTORY RESTRICTED
ORG
ORGORG
ORG
7
COMMERCIAL KEYS
KEYMARK KEYS
COMMERCIAL OEM / OTHER
KEYMARK DEALER
KEYMARK END-USER
KEYMARK SILVER
(Original & Biaxial Version) If you have a Medeco key that isnt on this chart, it is highly likely that it is from an original equipment manufacturer using Medeco products. You will need to
return to the original manufacturer of the product for duplicate keysBIAORG
R
PAT. NO. 4,635,455
R
= KeyMark x4 patent expiration date: 2027.
= KeyMark patent expiration date: