C A T A L O G U E 2 0 1 2
DC Inverter VRF Air Conditioning Systems VRF
22
YOUR CONDITIONS!
Since 1916, pioneers in the US market, by designing and manufacturing innovative air conditioning and
heat pump units. The companys primary competitive advantage is the use of its know-how expertise gained in the past,
to build air conditioning systems of the future.
The key to units' success is that they are specifically designed to enable the modern individual invent his
own custom made living and working conditions. Regulating effectively the natural environment,
units can create silently the perfect indoor conditions; your conditions!
All units carry a2-year Warranty for the compressor and for all parts of the unit.
units can be found all across Europe in a
continuously growing selected network of air conditioning
professionals!
Their excellent quality and operational efficiency has been
awarded by the European Union with the highest standard
certificates.
Furthermore, the use of the environmental friendly refrigerants
(freon) do not contribute to the increase of the global warming
environment.
33
INV
Features Pages
Higher Efficiency 4-5Better Comfort 6-7Higher Reliability 8-9Better Versatility 10-11Easy Installation & Maintenance 12-13INV Mini 14-15
Outdoor Units Pages
Line up 16-17Specifications 18-21
Indoor Units Pages
Line up 22-23Duct Type 24-27Slim Duct Type 28-29Four-way Cassette Type 30-33One-way Cassette Type 34Floor Standing Type 35Wall Mounted Type 36-37Floor Ceiling Type 38-40Concole Type 41Treated Fresh Air Duct Type 42-43
Control System Pages
Control Network Sketch 44-45Controllers Comparison 46Comments of Control Functions 47Wired Remote Controller 48-49Wireless Remote Controller 50-51Group Controller 52Smart Zone Controller 53Centralized Controller 54IR Receiver & Key-card Control Board 55Communication Module 56Commissioning Program 57RS-422/485 Repeater 58RS-232 to RS-422/485 Converter 59INVENTOR Eudemon 2009 PC SUIT 60-61Piping Design Program 62-63
Energy Recovery Ventilation 64-66Connection Branches 67
index
4) Significantly improved EER/COP Significantly greater efficiency is realized by the use of DC Inverter Hermetic Scroll Compressors with high-pressure chamber design, improved DC inverter driving technology and large heat exchanger.
EER is the efficiency rate= cooling capacity (kW) cooling power input (kW)
COP is the coefficient of performance = heating capacity (kW) heating power input.
EER/COP values are based on INVENTOR laboratory testing method The data refers to a 8HP outdoor unit
2.5
3.0
3.5
4.0
3.2
4.07
2.5
3.0
3.5
3.7
4.37
4.0
HIGHER EFFICIENCY
Heat Exchanger
Fan Motor
Compressor
) High efficiency compressorHigh pressure chamber design
Whats high pressure chamber? The compressed gas that is discharged from the fix scroll, fulfills the whole hermetic chamber of the compressor. Then, when the whole compressor shell has high temperature and there is high pressure inside the compressor, the gas goes out from the exhaust.
Whats the Benefit of High Pressure Chamber? Direct suction in high pressure chamber compressor. No loss from overheat suction. Increased compressor efficiency up to 3-5%.
High Pressure
Fixed Scroll
Orbiting Scroll
Intermediate Pressure
Low Pressure
Intermediate Pressure Chamber
Motor in high Pressure
Suction
Discharge
New DC motor (concentrated winding) raises the low frequency performance
HP chamber structure can raise the high and middle frequency performance
27% increase of EER
18% increase of COP
Formermodel INV
Formermodel INV
5 3%
7%
Former model INV
Former model
Air
flow
vol
ume
Air
flow
vol
ume
) DC Fan motorCompared with the former model, airflow volume is increased 3% with the same single fan and 7% with the new dual fan, but the power consumption is decreased by 5% with the DC inverter motor.
8HP/10HP Models
12HP/14HP Models
) Heat Exchanger The bigger condenser increases
the heat-exchange area, improving the efficiency.
Former model:
2098x38.1x1156
INV:
2248x38.1x1190
INV
Compared with the normal fin, the heat exchange efficiency of the louver is increased by 5%.
Former model:
Normal flat fin
INV:
Louver fin with golden coated
Special thickened inner groove copper tube enhances heat exchanging performance.
Comparing with normal compressor, the DC Inverter Scroll compressor can save up to 40% of energy consumption in a year.
Improved DC inverter motor Low frequency performance is highly raised thanks to the concentrated winding.
With stepless power regulating technology, the DC inverter compressor achieves stepless output regulation between 20Hz-120Hz
0 20
Com
pres
sor
effic
ienc
y
Distributed winding Concentrated winding
Rotating speed (/rps)
7%
Formermodel INV
Formermodel INV
6) Quiet Operation Quiet operation during night timeThe Intelligent adjustment of the outdoor fan control can minimize the operation noise during night time.
It can be reduced up to 8dB(A). So the operating noise at night is lower, at 50dB(A).
Low noise designOUTDOOR UNIT
HP chamber compressor has lower exhaust pressure fluctuation, so the noise is lower.
INDOOR UNIT
Low noise indoor unit
BETTER COMFORT
The optimized design of the condensing fan blade reduces the air flow turbulence among blades. So, the noise is lower.
58dB(A) 50dB(A)
Average 2dB(A) down
Capacity Operating sound
Heat load Capacity Operating sound
Optimized
Original design New design with higher performance &lower noise 4dB(A) less!
37dB(A)Office
Duct Type with High ESP
37dB(A)Hotel
Slim Duct Type
28dB(A)Bedroom
Wall Mounted Type
37dB(A)Reception
Four-way Cassette Type
Qui
et c
ompr
esso
r
7) Comfortable Precise temperature controlThe EXV (Electronic Expansion Valve) of each Indoor unit responds to the loading changes of indoor environment, so it continually adjusts the flow rate of refrigerant.
Meanwhile, the outdoor unit with DC inverter compressor provides the capacity with certain amount of refrigerant exactly according to the total demands of the indoor units.
With this Variable Refrigerant Flow (VRF) technol-ogy, we can quickly get a nearly constant room temperature. The typical temperature fluctuation that occurs with a conventional ON/OFF control system is eliminated.
Intelligent defrost technologyTraditional defrost program
Simply executes defrosting according to a certain time.
The defrost function may still start even if there is no such (defrosting) demand.
Intelligent defrost program
Humanized technology which considers the maxi-mization of energy saving.
Defrosting program that is designed under the consideration of heating efficiency and operation reliability.
Precise defrosting timing, which is intelligent indeed.
Its an optimized defrosting program, which will be performed only when the systems pressure is too low. This can obviously lengthen the time gap between two defrost operations and reduce the times of defrosting.
Heating capacity loss has been decreased by 75% with highly comfortable heating operation.
Individual controlThe set temperature of each room may vary by the individual thermostat control of each indoor unit.
Cooler Uncomfortable
Comfortable
Less Cool Uncomfortable
Temperature fluctuation of th
e room
Non VRF INV
Hea
ting
Cap
acit
yH
eati
ng C
apac
ity
Heating
Heating
Defrosting Defrosting
Hea
t Lo
ss
10mins 50mins 10mins 10mins50mins
Time
Defrosting
Time
Defrosting starts if the unit detects frost Defrosting stops after completion
OFF
200C
240C 270C220C
260C
8) Modular operating The operating priority sequence of the outdoor unit
modules will be changed without restart when the system accumulatively operates for 12 hours. This can maximize the service life of the system.
HIGHER RELIABILITY Emergency operationEach module is an independent sub-system. The whole system wont fail down even if partial malfunction occurs. If a malfunction occurs at any module, there can be performed an emergency operation. This can simply be achieved by setting up manually the outdoor PCB switches.
12hours Rotation
12hours Rotation
12hours Rotation
12hours Rotation
Operating
Malfunction Emergency Operation
) Continuous operation of indoor unitsEach indoor unit is controlled individually on the system network. This allows all indoor units to continue operating even if an error occurs at any indoor unit on the VRF system.
Failure
) Wide voltage range operationThe unit can safely operate within 342V-456V
) Power supply securityWith power supply security, the outdoor unit will start auto-protection if the power voltage or the current is out of the normal range. Protection will be relived automatically if the power condition resumes normal.342V 456V
Safe operation range
9) PCB protection designWith unique high efficiency radiating air-dust design, the outdoor electric box is designed as water-proof, dust-proof, damp-proof and well ventilated. This can ensure the required condition for the electric elements even in tropi-cal conditions. Also, it improves the systems reliability and service life.
) Anti-corrosionThe primary material of Golden Fin is Al-Mn (Aluminum-Manga-nese) anti-rust alloy, which is coated with the Golden Protection Layer (Components: Epoxy Resin & Modified Acrylic, Silicon free). The anti-corrosive performance in salt-spray testing is 200%-300% higher than normal Blue Fin*.
*Salt-spary testing result is from INVENTOR materials chemistry testing laboratory
) New generation of oil return controlThe pressure control achieves an optimized oil return of the system. As a result, the operating life of the compressor is greatly improved.
Electric Box
Baffle
Electric Box Cover
Guide louver
Positive pressure
Air inlet
Front pane
Air outlet
Negative pressure
Hydrophilic Layer
Golden Protection Layer (Epoxy resin & Modified Acrylic)
Al-Mn-corrosive alloy
) High efficiency oil-balanced technologyHigh-pressure chamber compressor with oil-balanced pipe can automatically drain out the excess oil. This can prevent an oil-unbalance between the compressors.
New patented oil separator allows the oil separating efficiency up to 99%. Oil equalizing pipe connection designed at the outside of the module allows high reliability.
Before Oil Balanced After Oil Balanced
Backflow
Suction pipe
Discharge pipe
Auto-oil pipe
Compressors
Oil storage tank
Oil equalizing pipe Oil equalizing pipe
10
) Long piping design Maximum total piping length --- 500m Maximum actual piping length --- 150m Maximum equivalent piping length --- 175m Maximum height difference between indoor units --- 15m Maximum height difference between outdoor
and indoor units --- 50m*
Maximum piping length from first indoor branch to the farthest indoor unit --- 40m
* This value is based on the case that the outdoor unit is located above the indoor unit. If the outdoor unit is located underneath the indoor unit, the value is 40m.
) Wide operation rangeThe unit can operates in wide range, greatly reducing the ambient temperature limitation.
If the required capacity of indoor units is 50% higher than the outdoor unit,
the cooling range may be lower up to 150C
If the required capacity of indoor units is 50% lower than the outdoor unit, the cooling range may be up to 50C.
BETTER VERSATILITY) Higher Static pressure
of outdoor unitThe maximum external static pressure (ESP) of the outdoor fan can reach up to 75Pa*.
The outdoor unit can be installed in the equipments room of high buildings.
* Default ESP of the product is 40Pa. If higher ESP is required, please contact us.
Heating
Cooling
15
0m
40
m
50
m1
5m
11
) Compact DesignCompact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
Former model (8HP) INV (8HP)
Former model (8HP + 8HP) INV (16HP)
) Modular outdoor unit design Various combinations from 8HP to 64HP with 2HP increments. Max capacity of outdoor unit is 180kW (4 x modules)
) Various combinations
Up to 110 sets of indoor units can be connected**For the standard model that 4 models connect in parallel, up to 64 indoor units can be connected. If more indoor units are required to be connected please contact us.
12 types and 69 models. Maximum diversity is 135%
17
72
mm
880mm990mm
16
70
mm
770mm930mm
17
72
mm
880mm(990+990)mm
16
70
mm
770mm1340mm
17%reduction
41%reduction
Floor area: 0,87m2 Floor area: 0,72m2
Floor area: 1,74m2 Floor area: 1,03m2
12
) Easier maintainability Special-designed elecric box.The electric box can be opened by inverting downwards, for easy maintenance.
Error display & Self-diagnostics system.Any malfunction can be judged by the LED display that is on the main board (different combinations of ON/OFF or BLINK).
Self diagnostics LED display on the LED display on the system display connection board connection board
EASY INSTALATION & MAINTENANCE
13
) Easier transportation & installations Light weight
Former model (8HP+8HP): INV (16HP):
240x2=480kg 370kg
Transportation by forklift
Compact designWith compact design, the outdoor unit can be carried to the roof of a building through elevator. No crane is needed.
Traditional Central Air Conditioner
Optimized base frameOptimized base frame. The locating and fixing of the outdoor unit during installation is more convenient and reliable.
Five-Way piping connection Piping and wiring are available to the front and back,
left and right, bottom.
The five-way piping connection reduces installation difficulty and cost. Improves the installation efficiently.
INV
14
) Flexible Design Long piping design Maximum total piping length --- 150m
Maximum actual piping length --- 70m
Maximum equivalent piping length --- 80m
Maximum height difference between indoor units --- 10m
Maximum height difference between outdoor and indoor units --- 30m*
Maximum piping length from first indoor branch and the farthest indoor unit --- 25m
* This value is based on the outdoor unit to be located above the indoor unit. If the outdoor unit is located underneath the indoor unit, the value is 25m.
Compact Design
Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
Former Model INV
) Wide voltage range operationThe unit can safely operate within the power supply voltage of 185V to 264V.
INV MINI
70
m
25
m
30
m1
0m
12
50
mm
1100mm 340mm
12
50
mm
950mm340mm
Floor area: 0,374m2 Floor area: 0,323m2
14%reduction
185V 264V
Safe operation range
70
m
25
m
30
m
12
50
mm
950mmmmmm
15
) High efficiencyDC inverter rotary compressor
) Easy InstallationWhen total piping length is less than 50m [(A+B+C+D+a+b+c+d) 50m], no additional refrigerant is required.
) Powerful heating in low temperatureWhen outdoor ambient temperature is low, the system can automatically increase the heating effect according to its judgment on parameters. Heating performance is improved by 15%, which brings great comfort.
) Capacity
) ComfortAuto quiet operation
The unit is ensured to operate with the lowest noise due to the ultra-low fan speed and auto adjustment according to system parameters. The operation noise of the unit is reduced by 3dB(A) at lower loading.
3dB(A)
Ope
rati
on n
oise
MODEL INV-Pd100W/NaB-K INV-Pd120W/NaB-K INV-Pd140W/NaB-K INV-Pd160W/NaB-K
CapacityHP 3.5 4.0 5.0 6.0kW 10 12 14 16
Power Supply 1Phase, 220-240V, 50Hz
16
OUTDOOR UNITS LINEUPMODEL INV-Pdm224W/NaB-M (8HP)
INV-Pdm280W/NaB-M (10HP)
INV-Pdm335W/NaB-M (12HP)
INV-Pdm400W/NaB-M (14HP)
INV-Pdm450W/NaB-M (16HP)
INV-Pdm224W/NaB-M (8HP)
INV-Pdm228W/NaB-M (10HP)
INV-Pdm335W/NaB-M (12HP)
INV-Pdm400W/NaB-M (14HP)
INV-Pdm450W/NaB-M (16HP)
INV-Pdm504W2/NaB-M (18HP)
INV-Pdm560W2/NaB-M (20HP)
INV-Pdm615W2/NaB-M (22HP)
INV-Pdm670W2/NaB-M (24HP)
INV-Pdm730W2/NaB-M (26HP)
INV-Pdm785W2/NaB-M (28HP)
INV-Pdm850W2/NaB-M (30HP)
INV-Pdm900W2/NaB-M (32HP)
17
MODEL INV-Pdm224W/NaB-M (8HP)INV-Pdm280W/NaB-M (10HP)
INV-Pdm335W/NaB-M (12HP)
INV-Pdm400W/NaB-M (14HP)
INV-Pdm450W/NaB-M (16HP)
INV-Pdm950W3/NaB-M (34HP)
INV-Pdm1008W3/NaB-M (36HP)
INV-Pdm1605W3/NaB-M (38HP)
INV-Pdm1130W3/NaB-M (40HP)
INV-Pdm1180W3/NaB-M (42HP)
INV-Pd-m11253W3/NaB-
M (44HP)
INV-Pdm1300W3/NaB-M (46HP)
INV-Pd-m11350W3/NaB-
M (48HP)
INV-Pdm1405W4/NaB-M (50HP)
INV-Pdm1456W4/NaB-M (52HP)
INV-Pdm1512W4/NaB-M (54HP)
INV-Pdm1570W4/NaB-M (56HP)
INV-Pdm1650W4/NaB-M (58HP)
INV-Pdm1700W4/NaB-M (60HP)
INV-Pdm1750W4/NaB-M (62HP)
INV-Pdm1800W4/NaB-M (64HP)
18
SPECIFICATIONSINV Mini
RATING CAPACITY HP 3.5 4 5 6
MODEL INV-Pd 100W/NaB-K INV-Pd 120W/NaB-K INV-Pd 140W/NaB-K INV-Pd 160W/NaB-K
Combination units - - - -
Connectable indoor unit
Maximum 6 7 8 9Cooling Capacity (kW) 5.0-13.5 6.0-16.2 7.0-18.9 8.0-21.6
Power supply 1-Phase, 220-240V, 50Hz
CapacityCooling (kW) 10.0 12.0 14.0 16.0Heating (kW) 11.0 14.0 15.4 17.6
Power consumptionCooling (kW) 2.86 3.50 4.36 4.98Heating (kW) 2.60 3.40 4.05 4.85
Compressor Type DC inverter dual-rotor type compressor x 1
Airflow ratem3/h 6200 6200 6000 6400CFM 3642 3642 3525 3759
Sound pressure level (dB(A)) 58 58 58 58Dimensions WxDxH (mm) 950x340x1250 950x340x1250 950x340x1250 950x340x1250Net weight
kg111 111 111 115
Refrigerant charge 7.5 7.5 7.5 7.5
Operation rangeC Cooling: 10 to 48, Heating: -20 to 27F Cooling: 18 to 118.4, Heating: -4 to 81
Connection pipe diameter
Gasinch
5/8 5/8 5/8 3/4
Liquid 3/8 3/8 3/8 3/8
Basic ModuleRATING CAPACITY HP 8 10 12 14 16
MODEL INV-Pdm 224W/NaB-MINV-Pdm 280W/
NaB-MINV-Pdm 335W/
NaB-MINV-Pdm 400W/
NaB-MINV-Pdm 450W/
NaB-M
Combination units -
Connectable indoor unit
Maximum 14 14 16 16 16Cooling Capacity (kW) 11.2 - 30.2 14.0 - 37.8 16.8 - 45.2 20.0 - 54.0 22.5 - 60.8
Power supply 3-Phase, 380-415V, 50Hz
CapacityCooling (kW) 22.4 28.0 33.5 40.0 45.0Heating (kW) 25.0 31.5 37.5 45.0 50.0
Power consumptionCooling (kW) 5.52 7.52 9.23 12.45 14.32Heating (kW) 5.82 7.70 9.38 11.2 13.90
Compressor Configration* DCx1+Cx1 DCx1+Cx2
Airflow ratem3/h 10000 10000 13000 13000 13000CFM 5874 5874 7636 7636 7636
Sound pressure level (dB(A)) 58 58 60 61 61Dimensions WxDxH mm 930x770x1670 1340x770x1670Net weight
kg255 255 350 350 370
Operating range 275 275 380 380 400Refrigerant charge 12 13 15 16 17
Operation rangeC Cooling: -5 to 48, Heating: -20 to 27 F Cooling: 23 to 118.4, Heating: -4 to 81
Connection pipe diameter
Gasinch
7/8 7/8 9/8 9/8 9/8
Liquid 3/8 3/8 1/2 1/2 1/2
*DC: DC inverter scroll compressor C: Constant speed scroll compressor
19
Combination ModulesRATING CAPACITY HP 18 20 22 24 26
MODEL INV-Pdm 504W2/NaB-MINV-Pdm 560W2/
NaB-MINV-Pdm 615W2/
NaB-MINV-Pdm 670W2/
NaB-MINV-Pdm 730W2/
NaB-M
Combination units
INV-Pdm 224W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 335W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 400W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 450W/NaB-M
Connectable indoor unit
Maximum 30 32 32 32 32Cooling Capacity (kW) 25.2-68 28.0-75.6 30.8-83.0 33.5-90.5 36.5-98.6
Power supply 3-Phase, 380-415V, 50Hz
CapacityCooling (kW) 50.4 56.0 61.5 68.0 73.0Heating (kW) 56.5 63.0 69.0 76.5 81.5
Power consumptionCooling (kW) 13.04 15.04 16.75 19.97 21.84Heating (kW) 13.52 15.40 17.08 18.90 21.60
Compressor Configration* (DCx1+Cx1)x2 (DCx1+Cx1)+(DCx1+Cx2)
Airflow rate m3/h 10000x2 10000+13000 CFM 5874x2 5874+7636
Sound pressure level (dB(A)) 62 62 62 62 63Dimensions WxDxH mm (930x770x1670)+(930x770x1670) (930x770x1670)+(1340x770x1670)Net weight
kg255+255 255+255 255+350 255+350 255+370
Refrigerant charge 13+13 13+15 13+15 13+16 13+17
Operation rangeC Cooling: -5 to 48, Heating: -20 to 27 F Cooling: 23 to 118.4, Heating: -4 to 81
Connection pipe diameter
GasInch
9/8 9/8 9/8 9/8 11/8
Liquid 5/8 5/8 5/8 3/4 3/4
RATING CAPACITY HP 28 30 32 34 36
MODEL INV-Pdm 785W2/NaB-MINV-Pdm 850W2/
NaB-MINV-Pdm 900W2/
NaB-MINV-Pdm 950W3/
NaB-MINV-Pdm 1008W3/
NaB-M
Combination units
INV-Pdm 335W/NaB-M
INV-Pdm 450W/NaB-M
INV-Pdm 400W/NaB-M
INV-Pdm 450W/NaB-M
INV-Pdm 450W/NaB-M
INV-Pdm 450W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 400W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 280W/NaB-M
INV-Pdm 450W/NaB-M
Connectable indoor unit
Maximum 32 32 32 48 48Cooling Capacity (kW) 39.3-106.0 42.5-114.8 45.0-121.5 47.5-128.3 50.4-136.1
Power supply 3-Phase, 380-415V, 50Hz
CapacityCooling (kW) 78.5 85.0 90.0 96.0 101.0Heating (kW) 87.5 95.0 100.0 108.0 113.0
Power consumptionCooling (kW) 23.55 26.77 28.64 27.49 29.36Heating (kW) 23.28 25.10 27.8 26.60 29.30
Compressor Configration* (DCx1+Cx2)x2 [(DCx1+Cx1)x2]+(DCx1+Cx2)
Airflow rate m3/h 13000x2 10000x2+13000 CFM 7636x2 5874x2+7636
Sound pressure level (dB(A)) 63 63 63 64 64Dimensions WxDxH mm (1340X770X1670)+(1340X770X1670) (930x770x1670)+(930x770x1670)+(1340x770x1670)Net weight
kg350+370 350+370 370+370 255+255+350 255+255+370
Refrigerant charge 15+16 18+17 17+17 13+13+16 13+13+17
Operation rangeC Cooling: -5 to 48, Heating: -20 to 27 F Cooling: 23 to 118.4, Heating: -4 to 81
Connection pipe diameter
GasInch
11/8 11/8 11/8 11/8 11/8
Liquid 3/4 3/4 3/4 3/4 3/4
*DC: DC inverter scroll compressor C: Constant speed scroll compressor
20
RATING CAPACITY HP 50 52 54 56 58
MODEL INV-Pdm1405W4/NaB-MINV-Pdm1456W4/
NaB-MINV-Pdm1512W4/
NaB-MINV-Pdm1570W4/
NaB-MINV-Pdm1650W4/
NaB-M
Combination units
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm335W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
Connectable indoor unit
Maximum 64 64 64 64 64Cooling Capacity (kW) 70.3-189.7 72.8-196.6 75.6-204.1 78.5-212.0 82.5-222.8
Power supply 3-Phase, 380-415V, 50Hz
CapacityCooling (kW) 141.0 146.0 151.5 155.0 163.0Heating (kW) 158.0 163.0 169.0 176.5 181.5
Power consumption
Cooling (kW) 41.84 43.68 45.39 48.61 50.48Heating (kW) 40.05 43.20 44.88 46.70 49.90
Compressor Configration* [(DCx1+Cx1) x2]+[(DCx1+Cx2)x2] (DCx1+Cx1)+[(DCx1+Cx2) x3]
Airflow rate m/h 10.000x2+13.000x2 10.000+13.000x3 CFM 5.874x2+7.636x2 5.874+7.636x3
Sound pressure level (dB(A)) 65 65 65 65 65
Dimensions WxDxH mm (930x770x1.670)+(930x770x1.670)+ +(1.340X770X1670)+(1.340X770X1.670)
(930x770x1.670)+(1.340x770x1.670)+ +(1.340x770x1670)+(1.340x770x1.670)
Net weightkg
255+255+350+370 255+255+350+370 255+350+370+370 255+350+370+370 255+370+370+370
Refrigerant charge 13+13+16+17 13+13+17+17 13+15+17+17 13+16+17+17 13+17+17+17
Operation rangeC Cooling: -5 to 48, Heating: -20 to 27F Cooling: 23 to 118.4, Heating: -4 to 81
Connection pipe diameter
GasInch
1 3/4 1 3/4 7/4 2 1/8 2 1/8
Liquid 7/8 7/8 7/8 1 1
*DC: DC inverter scroll compressor C: Constant speed scroll compressor
Combination ModulesRATING CAPACITY HP 38 40 42 44 46 48
MODEL INV-Pdm 1065W3/NaB-MINV-Pdm
1130W3/NaB-MINV-Pdm
1180W3/NaB-MINV-Pdm
1235W3/NaB-MINV-Pdm
1300W3/NaB-MINV-Pdm
1350W3/NaB-M
Combination units
INV-Pdm280W/NaB-M
INV-Pdm335W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm280W/NaB-M
INV-Pdm400W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm280W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm335W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm400W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm450W/NaB-M
INV-Pdm450W/NaB-M
Connectable indoor unit
Maximum 48 48 48 48 48 48Cooling Capacity (kW) 53.3-143.8 56.5-152.6 59.0-159.3 61.81-166.7 65.0-175.5 67.5-182.3
Power supply 3-Phase, 380-415V, 50Hz
CapacityCooling (kW) 106.5 113.0 118.0 123.5 130.0 135.0Heating (kW) 119.0 126.5 131.5 137.5 145.0 150.0
Power consumption
Cooling (kW) 31.07 34.29 36.16 37.87 41.09 42.96Heating (kW) 30.98 32.80 35.50 37.18 39.00 41.70
Compressor Configration* (DCx1+Cx1)+[(DCX1+Cx2)x2] (DCx1+Cx2)x3
Airflow rate m3/h 10000+13000x2 13000X3 CFM 5874+7636x2 7636x3
Sound pressure level (dB(A)) 64 64 64 65 65 65Dimensions WxDxH mm (930x770x1670)+(1340x770x1670)+(1340x770x1670) (1340x770x1670)+(1340x770x1670)+(1340x770x1670)Net weight
kg255+350+370 350+370+370 350+370+370 370+370+370
Refrigerant charge 13+15+17 13+16+17 13+17+17 15+17+17 16+17+17 17+17+17
Operation rangeC Cooling: -5 to 48, Heating: -20 to 27F Cooling: 23 to 118.4, Heating: -4 to 81
Connection pipe diameter
GasInch
1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8
Liquid 3/4 3/4 3/4 3/4 3/4 3/4
21
Combination ModulesRATING CAPACITY HP 60 62 64MODEL INV-Pdm1700W4/NaB-M INV-Pdm1750W4/NaB-M INV-Pdm1800W4/NaB-M
Combination units
INV-Pdm335W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
Connectable indoor unit
Maximum 64 64 64Cooling Capacity (kW) 85.0-230.0 87.5-236.3 80.0-243.0
Power supply 3-Phase, 380-415V, 50Hz
CapacityCooling (kW) 168.0 175.0 180.0Heating (kW) 187.5 195.0 200.0
Power consumption
Cooling (kW) 52.19 55.41 57.21Heating (kW) 51.80 52.90 55.60
Compressor Configration* (DCx1+Cx2) x4
Airflow rate m3/h 13000x4 CFM 7636x4
Sound pressure level (dB(A)) 66 66 66Dimensions WxDxH mm (1340x770x1670)+(1340x770x1670)+(1340x770x1670)+(1340x770x1670)Net weight
kg350+370+370+370
Refrigerant charge 15+17+17+17 16+17+17+17 17+17+17+17
Operation rangeC Cooling: -5 to 48, Heating: -20 to 27F Cooling: 23 to 118.4, Heating: -4 to 81
Connection pipe diameter
GasInch
2 1/8 2 1/8 2 1/8
Liquid 1 1 1
*DC: DC inverter scroll compressor C: Constant speed scroll compressor
22
INDOOR UNITS LINEUP
CAPACITY INDEX (kW) 2.2 2.8 3.6 4.5 5.0 5.6 6.3
Duct Type(EXV Integrated)
Slim Duct Type(EXV Integrated)
Four-way Cassette Type(EXV Integrated)
Compact Four-wayCassette Type(EXV Separated)
One-way Cassette Type(EXV Separated)
Floor Standing Type
Concole Type
Floor Ceiling Type(EXV Integrated)
Wall Mounted Type(EXV Separated)
Wall Mounted Type(EXV Integrated)
Treated Fresh AirDuct Type
23
7.1 8.0 9.0 10.0 11.2 12.5 14.0 22.4 28.0
24
) Highly flexible installation Highly flexible installation is possible to satisfy various needsInstallation examples
Flexible and easy to install in type-L, type-U and in large rooms
) Fresh air function option for 5.6kW and above units
DUCT TYPE
Supply air duct Indoor unit
Canvas air duct
Long life filter
Supply air duct
Return air inlet
Long life filterIndoor unit
Maintenance access
eeds
25
) Drain pump lift reaches 1000mmOnly available for INV(L)-R*PS/NaB-K
) Easy maintenance Long life and washable filter with buckles can be easily disassembled from each direction. Compact size has been achieved by significantly reducing the width of the outdoor units compared
to previous models.
Former structure: push pull type New structure: with buckles
The former structure is not easy to disassembly. The new structure makes the disassembly convenient.
) HIGHER ESP & lower noiseThe ESP is obviously upgraded while the noise is almost at the same level as before.
Former model Low ESP of new model Former model New model (In low ESP)
High ESP of new model
) Key-card control
ES
P (P
a)
Sou
nd le
vel (
dB(A
))
Model (kW) Model (kW)
26
Duct Type (With drain water pump)MODEL INV-R22PS/NaB-K INV-R28PS/NaB-K INV-R36PS/NaB-K INV-R45PS/NaB-K
Power supply 1-Phase, 220-240V, 50Hz
CapacityCooling (kW) 2.2 2.8 3.6 4.5Heating (kW) 2.5 3.2 4.0 5.0
Power consumption (W) 75 80 80 140
Airflow rate m3/h 450 570 570 700 CFM 265 335 336 412
Sound pressure level (H/M/L) (dB(A)) 37/35/33 39/37/35 39/37/35 40/38/36Standard Esp (H/L) (Pa) 50/20 50/20 50/20 50/20Dimensions (WxDxH) (mm) 880x665x250 980x721x266Net weight (Kg) 28.5 30.5 30.5 36
Connection pipe
Gas (Flare)Inch 3/8 3/8 1/2 1/2mm 9.52 9.52 12.7 12.7
Liquid (Flare)Inch 1/4 1/4 1/4 1/4mm 6.35 6.35 6.35 6.35
Drain PipeExternal dia. mm 20 20 20 30Thickness mm 1.5 1.5 1.5 1.5
MODEL INV-R56PS/NaB-KINV-R71PS/
NaB-KINV-R90PS/
NaB-KINV-R112PS/
NaB-KINV-R140PS/
NaB-K
Power supply 1-Phase, 220-240V, 50Hz
CapacityCooling (kW) 5.6 7.1 9.0 11.2 14.0Heating (kW) 6.3 8.0 10.0 12.5 15.0
Power consumption (W) 240 240 360 360 500
Airflow rate m3/h 1.000 1.100 1.700 1.700 2.000 CFM 589 647 1.000 1.000 1.177
Sound pressure level (H/M/L) (dB(A)) 44/42/40 45/43/41 48/46/44 48/46/44 50/48/46Standard Esp (H/L) (Pa) 60/30 60/30 80/40 80/40 100/50Dimensions (WxDxH) (mm) 1155x756x300 1425x736x300Net weight (Kg) 51 51 64 64 65.5
Connection pipe
Gas (Flare)Inch 5/8 5/8 5/8 5/8 5/8mm 15.9 15.9 15.9 15.9 15.9
Liquid (Flare)Inch 3/8 3/8 3/8 3/8 3/8mm 9.52 9.52 9.52 9.52 9.52
Drain PipeExternal dia. mm 30 30 30 30 30Thickness mm 1.5 1.5 1.5 1.5 1.5
27
Duct Type (Without drain water pump)MODEL IN-R22P/NaB-K
INV-R28P/NaB-K
INV-R36PS/NaB-K
INV-R45P/NaB-K
INV-R56P/NaB-K
INV-R71P/NaB-K
Power supply 1-Phase, 220-240V, 50Hz
CapacityCooling (kW) 2.2 2.8 3.6 4.5 5.6 7.1Heating (kW) 2.5 3.2 4.0 5.0 6.3 8.0
Power consumption (W) 75 80 80 140 240 240
Airflow rate m3/h 450 570 570 700 1.000 1.100 CFM 265 335 336 412 589 647
Sound pressure level (H/M/L) (dB(A)) 37/35/33 39/37/35 39/37/35 40/38/36 44/42/40 45/43/41Standard Esp (H/L) (Pa) 50/20 50/20 50/20 50/20 60/30 60/30Dimensions (WxDxH) (mm) 880x665x250 980x721x266 1155x756x300Net weight (Kg) 27 28.5 28.5 34 49 49
Connection pipe
Gas (Flare)Inch 3/8 3/8 1/2 1/2 5/8 5/8mm 9.52 9.52 12.7 12.7 15.9 15.9
Liquid (Flare)Inch 1/4 1/4 1/4 1/4 3/8 3/8mm 6.35 6.35 6.35 6.35 9.52 9.52
Drain PipeExternal dia. mm 20 20 20 30 30 30Thickness mm 1.5 1.5 1.5 1.5 1.5 1.5
MODEL INV-R90P/NaB-KINV-R112P/
NaB-KINV-R140P/
NaB-KINV-R224P/
NaB-MINV-R280P/
NaB-M
Power supply 1-Phase, 220-240V, 50Hz 3-Phase, 380-450V, 50Hz
CapacityCooling (kW) 9.0 11.2 14.0 22.4 28.0Heating (kW) 10.0 12.5 15.0 25.0 31.0
Power consumption (W) 360 360 500 1.600 1.600
Airflow rate m3/h 1.700 1.700 2.000 4.000 4.800 CFM 1.000 1.000 1177 2.381 2.857
Sound pressure level (H/M/L) (dB(A)) 48/46/44 48/46/44 50/48/46 56(H) 57(H)Standard Esp (H/L) (Pa) 80/40 80/40 100/50 200 220Dimensions (WxDxH) (mm) 1425x736x300 1463x799x389 1628x869x454Net weight (Kg) 62 62 63.5 88 113
Connection pipe
Gas (Flare)Inch 5/8 5/8 5/8 5/8 5/8mm 15.9 15.9 15.9 15.9 15.9
Liquid (Flare)Inch 3/8 3/8 3/8 3/8 3/8mm 9.52 9.52 9.52 9.52 9.52
Drain PipeExternal dia. mm 30 30 30 25.4 25.4Thickness mm 1.5 1.5 1.5 1.5 1.5
28
) Compact Design 2.2kW, 2.8kW, 3.6KwOnly 700mm in width, 200mm in height and 22kg in weight*, which is perfect to install in limited spaces like drop ceiling in hotel.
Note: the weight is 23kg for the unit of 3.6kW.
4.5kW, 5.6kWOnly 200mm in height, which can be installed in rooms with little depth as 240mm depth between the drop ceiling and ceiling slab.
Note: to be obtained locally
) Highly flexible installationHighly flexible installation is possible to satisfy various needs.
Installation examples
Example 1 Example 2
SLIM DUCT TYPE
700mm
200mm
200mm
900mm
Suspension bolt Suction duct*
Discharge grille Air filter Suction grille
AIR
AIR
Supply air duct Indoor unit
Canvas air duct
Long-life filter
Supply air duct
Long-life filter
Return air inlet
Indoor unit
Maintenance access
29
) Lower noisePlastic propeller housing, fan blade and intelligent-designed air-channel ensure air flow volume with lower operation noise.
For example the normal unit of 2.8kW has noise level up to 40dB(A), but the new unit of 2.8kW reduces the noise up to only 37dB(A).
) Drain pump lift reaches 1000mm
MODEL INV-R22P/NaE-KINV-R28P/
NaE-KINV-R36P/
NaE-KINV-R45P/
NaE-KINV-R56P/
NaE-KINV-R71P/
NaE-K
Power supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 2.2 2.8 3.6 4.5 5.6 7.1Heating (kW) 2.5 3.2 4.0 5.0 6.3 8.0
Power consumption (W) 64 64 70 91 91 100
Airflow rate m3/h 450 450 550 700 700 1000 CFM 265 265 324 412 412 589
Sound pressure level (H/M/L) (dB(A)) 37/35/33 37/35/33 39/37/35 40/38/36 41/39/37 42/40/38Standard Esp (Pa) 20 20 20 20 20 20Dimensions (WxDxH) (mm) 700x615x200 900x615x200 1100x615x200Net weight (Kg) 21 21 21 26 26 30
Connection pipe
Gas (Flare)Inch 3/8 3/8 1/2 1/2 5/8 5/8mm 9.52 9.52 12.7 12.7 15.9 15.9
Liquid (Flare)Inch 1/4 1/4 1/4 1/4 3/8 3/8mm 6.35 6.35 6.35 6.35 9.52 9.52
Drain PipeExternal dia. mm 20 20 20 30 30 30Thickness mm 1.5 1.5 1.5 1.5 1.5 1.5
30
) Four-way Cassette Type Compact, light weight and square panel in the same size for
easy installation.
A slim unit below 5.0kW is only 190mm in thickness. It can be installed in a narrow ceiling space of at least 210mm.
Drain pump fitted as standard with increased lift of 1100mm.
Compact Four-way Cassette Type Compact size of 650mm x 650mm for 2.8kW 5.6kW
Only 230mm in thickness that can be installed in a ceiling space of at least 250mm.
Drain pump fitted as standard with increased lift of 500mm.
FOUR WAY CASSETTE TYPE
650mm
650mm
960mm
960mm
) Four way Cassette Type) act Four way CCassette
31
Common characteristics Low noise with 3 dimensional blade.
The full-automatic operation, the 4-way air supply, the 3-speed fan setting and the strong circulating air flow volume, make the cooled or heated air to reach directly every corner of the room. This can be succeded even if the ceiling is higher than standard height.
The units below 7.1kW are applicable to The units below 8kW are applicable to height below 3m. height below 4.5m.
Air supply in different directions with 30-60 degree sweep for even better temperature distribution*
Note: the guide louver defaults to min. position of 30 during cooling, dry and fan operation, or maximum position of 60 during heating operation.
Designed with fresh air baffle for fresh air introduction. Long life and washable filter.
Diffuser
3-dimensional blade
32
Four-Way Cassette TypeMODEL INV-R28T/Na-K INV-R36T/Na-K INV-R45T/Na-K INV-R50T/Na-KPower supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 2.8 3.6 4.5 5.0Heating (kW) 3.2 4.0 5.0 5.8
Power consumption (W) 65 65 65 65
Aiflow ratem3/h 680 680 680 680CFM 400 400 400 400
Sound pressure level (H/M/L) (dB(A)) 37/35/33 37/35/33 37/35/33 37/35/33
Connection pipe
Gas (Flare)Inch 3/8 1/2 1/2 1/2mm 9.52 12.7 12.7 12.7
Liquid (Flare)Inch 1/4 1/4 1/4 1/4mm 6.35 6.35 6.35 6.35
Drain PipeExternal dia. (mm) 30 30 30 30Thickness (mm) 1.5 1.5 1.5 1.5
Main bodyDimensons (WxDxH) (mm) 840x840x190Net Weight (kg) 25 25 25 25
PanelDimensons (WxDxH) (mm) 950x950x60Net Weight (kg) 6.5 6.5 6.5 6.5
MODEL INV-R56T/Na-K INV-R63T/Na-K INV-R80T/Na-K INV-R90T/Na-KPower supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 5.6 6.3 8.0 9.0Heating (kW) 6.3 7.1 8.8 10.0
Power consumption (W) 83 83 83 133
Aiflow ratem3/h 1.180 1.180 1.180 1.860CFM 694 694 694 1.095
Sound pressure level (H/M/L) (dB(A)) 39/37/35 39/37/35 39/37/35 40/38/36
Connection pipe
Gas (Flare)Inch 5/8 5/8 5/8 5/8mm 15.9 15.9 15.9 15.9
Liquid (Flare)Inch 3/8 3/8 3/8 3/8mm 9.52 9.52 9.52 9.52
Drain PipeExternal dia. (mm) 30 30 30 30Thickness (mm) 1.5 1.5 2.5 3.5
Main bodyDimensons (WxDxH) (mm) 840x840x240 840x840x320
Net Weight (kg) 30 30 30 38
PanelDimensons (WxDxH) (mm) 950x950x60Net Weight (kg) 6.5 6.5 6.5 6.5
33
Compact Four-Way Cassette TypeMODEL INV-R22T/NaA-K INV-R28T/NaA-K INV-R36T/NaA-K INV-R45T/NaA-KPower supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 2.2 2.8 3.6 4.5Heating (kW) 2.5 3.2 4.0 5.0
Power consumption (W) 12 12 12 12
Aiflow ratem3/h 600 600 600 600CFM 353 353 353 353
Sound pressure level (H/M/L) (dB(A)) 47/44/41 47/44/41 47/44/41 47/44/41
Connection pipe
Gas (Flare)Inch 3/8 3/8 1/2 1/2mm 9.52 9.52 12.7 12.7
Liquid (Flare)Inch 1/4 1/4 1/4 1/4mm 6.35 6.35 6.35 6.35
Drain PipeExternal dia. (mm) 30 30 30 30Thickness (mm) 1.5 1.5 1.5 1.5
Main bodyDimensons (WxDxH) (mm) 570x570x230Net Weight (kg) 20 20 20 20
PanelDimensons (WxDxH) (mm) 650x650x50Net Weight (kg) 2.5 2.5 2.5 2.5
Four-Way Cassette TypeMODEL INV-R100T/Na-K INV-R112T/Na-K INV-R125T/Na-K INV-R140T/Na-KPower supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 10.0 11.2 12.5 14.0Heating (kW) 11.0 12.5 13.5 14.5
Power consumption (W) 133 133 133 133
Aiflow ratem3/h 1.860 1.860 1.860 1.860CFM 1.095 1.095 1.095 1.095
Sound pressure level (H/M/L) (dB(A)) 40/38/36 40/38/36 40/38/36 40/38/36
Connection pipe
Gas (Flare)Inch 5/8 5/8 5/8 5/8mm 15.9 15.9 15.9 15.9
Liquid (Flare)Inch 3/8 3/8 3/8 3/8mm 9.53 9.52 9.52 9.52
Drain PipeExternal dia. (mm) 30 30 30 30Thickness (mm) 1.5 1.5 1.5 1.5
Main bodyDimensons (WxDxH) (mm) 840x840x320Net Weight (kg) 38 38 38 38
PanelDimensons (WxDxH) (mm) 950x950x60Net Weight (kg) 6.5 6.5 6.5 6.5
34
ONE-WAY CASSETTE TYPE) High flexible Highly flexible installations for various needs.
) The unit is applicable to height below 3.5m
) Ultra quiet operationLow noise cross flow fan reduces vortex flow in the duct thus reducing the noise.
) Long life and washable filter
) Drain pump lift Drain pump flitted as standard with increased lift of 700mm.
) Detachable and washable grille
) ComfortableThe equal and gentle air supply design and the advanced air flow controlling design make the room temperature equal and bal-anced. So, the people inside the room feel more comfortable.
MODEL INV-R22Td/NaA-K INV-R28Td/NaA-K INV-R36Td/NaA-KPower supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 2.2 2.8 3.6Heating (kW) 2.5 3.2 4.0
Power consumption (W) 42 42 42
Aiflow ratem3/h 450 500 500CFM 265 294 294
Sound pressure level (dB(A)) 45/43/41 45/43/41 45/43/41
Connection pipe
Gas (Flare)Inch 3/8 3/8 1/2mm 9.52 9.52 12.7
Liquid (Flare)Inch 1/4 1/4 1/4mm 6.35 6.35 6.35
Drain PipeExternal dia. (mm) 30 30 30Thickness (mm) 1.5 1.5 1.5
Main bodyDimensons (WxDxH) (mm) 920x360x185Net Weight (kg) 16 16 16
PanelDimensons (WxDxH) (mm) 118043030Net Weight (kg) 3 3 3
) D i lift
35
Model / Heat pump INV-R71L/Na-K INV-R100L/Na-K INV-R140L/Na-K
CapacityCooling kW 7.00 10.00 14.00 Heating kW 8.00 11.00 15.00
Power supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50Motor power input W 160 185 200
Air flow volumem3/h 1100/1000/920 1600/1500/1300 1700/1600/1400 CFM 655/595/548 952/893/774 1012/952/833
Sound pressure level dB(A) 48/45/42 51/49/47 52/50/48
Connecting pipeGas inch 5/8 5/8 5/8Liquid inch 3/8 3/8 3/8
Drain pipeExternal dia. mm 31 31 31 Thickness mm 4.5 4.5 4.5
Dimensions WxDxH mm 502x316x1756 556x381x1896 556x381x1896 Net Weight Body kg 39.0 53 57
Auto diagnosis
Fashionable and novel appearance
Quiet operation
Intelligent drainage device
Long life filter
Wider air supply and swing angle
Dynamic color display
Horizontal and vertical swing
FLOOR STANDING TYPE
FCU Wired remote controller WK-010PA-K
Wireless
36
WALL MOUNTED TYPE
) Anti cool air designWhen heating in winter, intelligent anti cool air function is started.The unit blows only when the unit is pre-heated inside, to prevent it from blowing out cool air.
) Auto clean (under COOL & DRY mode)After the unit is turned off, the indoor fan will still operate in low speed in order to dry the inner components and parts. This way mould and odor are prevented from growing.
) Vertical auto swingWhen cooling, the cool air is directed across the room and then it sinks. When heating, the warm air is directed across the floor and then it rises.
Cooling Heating
) Low noise designThe advanced irregular-distance mixed flow fan, the unique duct design and the multi-grill auxiliary duct, make the operation highly efficient and the noise lower.
) Streamlined design for spaces without ceiling
) Ternary filtersTernary air filters with anti-mildew, static electric dust capture and anti-bacterial function.
Ternary filter
) Washable grilleThe front grille can be easily removed for washing.
37
MODEL INV-R50G/NaG-KINV-R56G/
NaG-KINV-R71G/
NaG-KINV-R71G/
NaB-KINV-R80G/
NaB-K
Power supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 5.0 5.6 7.1 7.1 8.0Heating (kW) 5.8 6.3 8.0 8.0 9.0
Power consumption (W) 60 70 70 63 65
Aiflow ratem3/h 630 800 800 1.200 1.200CFM 371 471 471 706 706
Sound pressure level (H/M/L) (dB(A)) 44/41/38 44/41/38 44/41/38 49/45/42 49/45/42Dimensions (WxDxH)(mm) 940x200x298 1008x221x319 1178x227x326Net weight (kg) 13 15 15 17.5 17.5
Connection pipe Gas (Flare)
Inch 1/2 5/8 5/8 5/8 5/8mm 12.7 15.9 15.9 15.9 15.9
Liquid (Flare)Inch 1/4 3/8 3/8 3/8 3/8mm 6.35 9.52 9.52 9.52 9.52
Drain PipeExternal dia. (mm) 28 28 28 30 30Thickness (mm) 4 4 4 1.5 1.5
EXV Position Integrated External
MODEL INV-R22G/NaG-KINV-R28G/
NaG-KINV-R36G/
NaG-KINV-R45G/
NaG-K
Power supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 2.2 2.8 3.6 4.5Heating (kW) 2.5 3.2 4.0 5.0
Power consumption (W) 50 50 60 60
Aiflow ratem3/h 500 500 630 630CFM 294 294 371 371
Sound pressure level (H/M/L) (dB(A)) 38/36/34 38/36/34 44/41/38 44/41/38Dimensions (WxDxH)(mm) 843x180x275 940x200x298Net weight (kg) 10.5 10.5 13 13
Connection pipe Gas (Flare)
Inch 3/8 3/8 1/2 1/2mm 9.52 9.52 12.7 12.7
Liquid (Flare)Inch 1/4 1/4 1/4 1/4mm 6.35 6.35 6.35 6.35
Drain PipeExternal dia. (mm) 28 28 28 28Thickness (mm) 4 4 4 4
EXV Position Intergrated
38
FLOOR CEILING TYPE) Compact and light weight
Only 238mm in height
) Ultra quiet operation
) Long life, detachable and washable grille
) Easy to install and good looking, satisfies more requirements
39
) Easy maintenanceConvenient disassembly and maintenance thanks to unique design.
Plastic filter with buckles Grill buckle Dismountable motor
) Wide discharge rangeWith cross-direction sweep. The air supply range is efficiently wider.
) Drain pump lift reaches 1100mm
40
Floor ceiling (EXV Integrated)MODEL INV-R28Zd/NaB-K INV-R36Zd/NaB-K INV-R50Zd/NaB-K INV-R71Zd/NaB-K
Power supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 2.8 3.6 5.0 7.1Heating (kW) 3.2 4.0 5.8 8.0
Power consumption (W) 55 55 110 140
Aiflow ratem3/h 650 650 950 1.400CFM 383 383 559 824
Sound pressure level (dB(A)) 40 40 45 49Dimensions (WxDxH) (mm) 1.220x225x700 1420x245x700Net weight (kg) 40 40 40 52
Connection pipe
Gas (Flare)Inch 3/8 1/2 1/2 5/8mm 9.52 12.7 12.7 15.9
Liquid (Flare)Inch 1/4 1/4 1/4 3/8mm 6.35 6.35 6.35 9.52
Drain PipeExternal dia. (mm) 17 17 17 17Thickness (mm) 1.75 1.75 1.75 1.75
MODEL INV-R90Zd/NaB-K INV-R112Zd/NaB-K INV-R125Zd/NaB-K INV-R140Zd/NaB-K
Power supply 1-Phase, 220-240V, 50HZ
CapacityCooling (kW) 9.0 11.2 12.5 14.0Heating (kW) 10.0 12.5 13.5 16.0
Power consumption (W) 180 250 250 250
Aiflow ratem3/h 1.600 2.000 2.000 2.000CFM 942 1.777 1.777 1.777
Sound pressure level (dB(A)) 51 55 55 55Dimensions (WxDxH) (mm) 1420x245x700 1700x245x700Net weight (kg) 54 64 66 66
Connection pipe
Gas (Flare)Inch 5/8 5/8 5/8 5/8mm 15.9 15.9 15.9 15.9
Liquid (Flare)Inch 3/8 3/8 3/8 3/8mm 9.52 9.52 9.52 9.52
Drain PipeExternal dia. (mm) 17 17 17 17Thickness (mm) 1.75 1.75 1.75 1.75
41
CONCOLE TYPE
Vertical swing
Anti-cold function
Quiet operation
Comprehensive protection
Auto restart
Compact design
Easier maintainability
MODEL INV-R28-C/Na-K INV-R36-C/Na-K INV-R28-C/Na-K
Power Supply 1-Phase, 220-240V,50Hz
Capacity Cooling (kW) 2.8 3.6 5.0Heating (kW) 3.2 4.0 5.5
Power consumption (W) 60 60 60
Air flow ratem3/h 500-430/370/280 600-520/440/360 650-620/500/410CFM 294-253/218/165 353-306/259/212 383-365/294/241
Sound pressure level (H/M/L) (db(A)) 38/33/26 40/37/32 46/41/35Dimenions (WxDxH) (mm) 700x215x600Net weight (kg) 16
Connection pipeGas
inch 3/8 3/8 1/2mm 9.52 9.52 12.7
Liquidinch 1/4 1/4 1/4mm 6.35 6.35 6.35
42
TREATED FRESH AIR DUCT TYPE) Provide fresh air of temperature that is close to the indoor
ambient, ensures fresh and comfortable indoor air. Note: The capacity of fresh air ducted unit should be less than 30% of the capacity of outdoor unit.
) Comfortable Makes you feel comfortable, like in the nature. It is introducing Treated fresh air supplying temperature is close to the outdoor fresh air, after treatment, in to the room. the indoor temperature (factory setting at 22 Celsius),
reducing the cooling load of other indoor units.
43
) Easy control Wired remote control Wireless remote control Centralized control Long-distance monitoring Sub-room switch Memory function Auto restart after power recover Weekly timer
) Flexible application The indoor unit with high static pressure can realize long-distance fresh air supply to all corners of the room. So, it is greatly
applicable to places that there is high density of people.
The standard pressure is 200Pa and the optional range is 50-300Pa.
MODEL INV-R140P/Na(X1.2)-KINV-R224P/Na(X2.0)-M
INV-R280P/Na(X2.5)-M
INV-R280P/Na(X3.0)-M
Power supply 220V, 50Hz, 1 Phase 380V, 50Hz, 3 Phase 380V, 50Hz, 3 Phase 380V, 50Hz, 3 Phase
Capacity (At rated ESP)
Cooling (kW) 14 22.4 28 28Heating (kW) 10 16 20 20
Power input1Cooling (kW) 0.5 1.1 1.1 1.1Heating (kW) 0.5 1.1 1.1 1.1
Aiflow VolumeCFM 706 1177 1471 1766m3/h 1200 2000 2500 3000
Sound pressure level (H/M/L) (dB(A)) 42 47 48 51
External Static Pressure
Rated (Pa) 150 200 200 200Range (Pa) 50~150 50~200 50~200 50~200
Dimensions (WxDxH) (mm) 1463x756x300 1500x1000x500 1500x1000x500 1500x1000x500Weight (kg) 63.5 130 150 150
Connection pipe
Valve Connection Type Flare Connection Brazing Connection Brazing Connection Brazing ConnectionLength (m) 7.5 7.5 7.5 7.5Gas additional charge (g/m) 54 54 54 54Liquid Pipe (Inch) 3/8 3/8 3/8 3/8Gas pipe (Inch) 5/8 7/8 7/8 7/8
44
CONTROL NETWORK SKETCH
System Air Conditioning Individual Control
Group Controller
ZJA011
Wired Remote Controller
Z63351F/Z63151F
Z60351F/Z60151F
Wired Remote Controller
ZX60451
Wireless Remote Controller
YB1FA Y512
Key-card Control Board Key-card
MK03
(Field supplied)
IR Receiver Unit
JS01
Communication module
ME30-00/E2
Communication module
ME30-00/E2
RS-422/485
Repeater
Note: Control network sketch is for reference only,
please refer to the equipment manuals for actual cable connection method.
45
Air ConditioningCentral Control
BuildingManagement
RS-232 to RS-422/485 Converter
RS-232 to RS-422/485 Converter
INVENTOR AC Eudemon 2009 (Monitoring Software)
FE30-00/A(M)
Internet
Web Monitoring Client
Communication module
ME30-00/E2
Centralized Controller CE51-24/E(M)
Smart Zone Controller
CE50-24/E
BMS Interface (Modbus)
ME30-00/E2
Commissioning Program (Software)
Text Parser
Module link
Transmission line (INV network)
Group controller line
Remote Controller line
Modbus network
IR receiver line
Key-card control board line
Key-card signal line
Building Management System
Web Monitoring Client
46
CONTROLLERS COMPARISON
ITEM
Wireless remote
Controller Y512
Wireless remote
controller YB1FA
Wired Remote
Controller Z63351F/Z60351*
Wired Remote
Controller XK02
Group Controller ZJA011
Smart Zone
Controller CE50-24/E
Centralized Controller CE51-24/
E(M)
INVENTOR AC Eude-mon 2009
BMS Interface (Modbus)
Connections
Max Nos. of Outdoor Units - - - - - - 64 n*255 n*255
Max Nos. of Wired Controller 1 1 1 1 16 16 1024 n*255*16 n*255*16
Max Nos. of Indoor Units 1 1 1 1 16 16 1024 n*255*16 n*255*16
Control functions
ON/OFF Mode Setting Fan Speed Vertical Swing Energy Saving Mode Drying Turbo Mode Sleeping Mode Light
Display
Errors Clock Week Room Temp. Lock Indoor unit Address
Timer
ON/OFF Timer Minimum Timer Gap 0.5h 1min 0.5h 0.5h 0.5h 0.5h 1min 1sec
Weekly Timer Centralized Week Timer Group Week Timer
Shielding
Shielding Centralized Shielding Group Shielding
Centralized Control
Centralized Control Group Control
Note: n: Nos. of serial port
Control functions availability is based on the indoor units. Please refer to the users manual of indoor unit for details.
47
COMMENTS OF CONTROL FUNCTIONS) ON/OFF Timer FunctionUnder ON/OFF state, set the unit to be automatically turned on or turned off in 0.5h hours (1n
48
WIRED REMOTE CONTROLLERZ60351F/Z63351F (Heat pump)
ON/OFF
Temperature setting
Fan speed setting
Energy-saving function
Room temperature display
Sleep function
Infrared remote control function is available and the remote controller is optional
Z60351F/Z63351F (Heat pump)
Z60151F/Z63151F (Cooling only)
ON/OFF Timer
Operation mode setting
Vertical swing
Self-diagnosis function (Error code display)
Memory function
Child lock function
Operating Mode Display (COOL, DRY, FAN, HEAT)
Sleep Mode Display
Room Temperature Display /Error Displa
Fan Speed Display (HIGH, MID, LOW, AUTO)
Set Temperature Display
Defrosting Display
Timer Display
Signal Receiver (For Remote Controller)
Mode Setting Button
Temperature Setting Button
Fan Speed Setting Button
Sleep Mode Setting Button*
Timer Setting Button
ON/OFF button
Model Name Z63351F / Z60351F Power Supply DC12V (Supplied by the indoor unit)Dimensions (HxWxD) (mm) 85x85x20Weight (g) 94
* Z60351F is for duct type indoor unit, and swing function is unavailable; Z63351F is for other types of indoor unit, button SLEEP changes to SWING, and sleep function is unavailable.
51
51
111FFFF (HHHeaattt pupumpmpppmpppppmppppppppp))))))))
111FFF F (CCCCCCCCCoooooooolilililingnggggngngngng ooooooooooo onlllnlnnnlnlnnly)yy)y)y)
49
WIRED REMOTE CONTROLLERZX60451
ON/OFF
Displayed as white characters on black background
Fan speed setting
Self-diagnosis function (Error code display)
Turbo cooling/heating function
Quiet function
Enquire and setting address of wired controller
ON/OFF Timer
Temperature setting
Vertical swing
Environmental temperature display
Evaporation function
Shield function
Infrared remote control function is available and the remote controller is optional
Touchable wired controller
Operating mode setting
Energy saving function
Sleep function
Memory function
Child lock function
Operating Mode Display (COOL, DRY, FAN, HEAT)
Sleep Mode Display
Fan Speed Display (AUTO, TURBO, LOW, MID, HIGH)
Temperature /Timer / Quiet Mode Setting button
Defrosting Operation Display
Enter / Cancel Button
Functions Setting Button
Key- card Display
Timer Display
Fan Speed Setting Button
Operation Mode Setting Button
On/Off Button
Timer Setting Button
Model Name ZX60451Power Supply DC12V (Supplied by the indoor unit)Dimensions (HxWxD) (mm) 92x92x24Weight (g) 116
Swing Display Lock Display
Set / Room Temprature Display
Function Display Area
50
WIRELESS REMOTE CONTROLLERY512
ON/OFF
Temperature setting
Fan speed setting
Child lock function
ON/OFF Timer
Operation mode setting
Vertical swing
Sleep function
Fan Speed setting button
Swing Button
Fan Speed Setting Display (HIGH, MID, LOW, AUTO)
Operation Mode Display/ (AUTO, COOL, DRY, FAN, HEAT)
Room Temperature/ Malfunction Display
Sleep Mode Display
Timer Display
Sleep Button
Light ON/OFF Button
Temperature/Timer Setting Button
Timer ON Setting Button
Timer OFF Setting Button
Mode Setting Button
ON/OFF Button
Model Name Y512Power Supply AAA 1.5Vx2Dimensions (HxWxD) (mm) 159x56x18Weight (g) 92
51
WIRELESS REMOTE CONTROLLERYB1FA
ON/OFF
Temperature setting
Fan speed setting
Energy-saving function
Room temperature display
Turbo cooling/heating function
Mute function
Child lock function
ON/OFF Timer
Operation mode setting
Vertical swing
Self-diagnosis function (Error code display)
Sleep function
Blow function
Memory function (Turbo, Energy save, Quiet, Evaporation, etc. )
Clock display
Operating Mode Display (AUTO, COOL, DRY, FAN, HEAT)
Model Name YB1FAPower Supply AAA 1.5Vx2Dimensions (HxWxD) (mm) 122x44x21Weight (g) 70
Sleep Mode Display
Temperature Type Display
Swing Angle Display
ON/OFF Button
Temperature/ Timer Setting Button
Fan Speed Setting Button
Clock Setting Button
Blow Function ON/OFF Button
Turbo Mode Setting Button
Fan Speed (HIGH, MID, LOW, AUTO)
Room Temperature/Malfunction Display
Timer Display
Child Lock Display
Light Displayer
Mode Setting Button
Swing Mode Setting Button
Timer Setting Button
Temperature Display Button
Light ON/OFF Button
Sleep Mode Setting Button
52
GROUP CONTROLLERZJA011
) Group monitoring control and group wired control are the two main control functions for group Controller.
Group monitoring controller can monitor or control 16 indoor units of a group for inquiry and single or centralized control.
Features:
For a region consisted of 1-16 indoor units both single and central control are available.
The wired controller buttons in a region of 16 indoor units can be shielded or locked.
It can time 16 indoor units in a region.
It has the function of power-off memory.
Note: Wired controller must be reserved with the indoor unit that has been matched.
Group wired controller could replace 1-16 selected wired controllers, in order to uniformly set or control the indoor units.
Features:
It can uniform the time for the selected indoor units.
It can replace the wired controller, in order to control the selected indoor units in a region.
It has the function of power-off memory.
Note: The wired controller that is matched with the indoor unit must be removed and the indoor unit must be re-energized after debugging.
No. Of indoor Unit
Model Name ZJA011Power Supply DC12V (Supplied by the indoor unit)Dimensions (HxWxD) (mm) 85x85x20Weight (g) 94
Inquiry/Control Display
Operating Mode Display/ (COOL, DRY, FAN, HEAT)
Error display for indoor or outdoor unit
Room temperature display/ Malfunction display
Fan Speed Display (AUTO, HIGH, MID, LOW)
Lock Display
Swing Display
Set Temperature/Timer Time Display
ON/OFF Button
Inquiry/Single or Central Control Setting Button
Operating Mode Setting Button (COOL, DRY, FAN, HEAT)
Long-Distance Shield Status Display
Value Setting Button for Temperature/ Timer/Indoor Unit Number Selecting (Under INQUIRY Status)
Forced Operation Display
Fan Speed/ Swing Setting Button
Defrosting Operating Display
Timer Button (Under SINGLE / CENTRAL Status) ON/OFF Timer Inquiring of On-line Indoor Uni (Under INQUIRY Status)
t ll thh t
53
SMART ZONE CONTROLLERCE50-24/E
When the indoor units are connected to 3 sets of INV outdoor units, the air duct type indoor unit can be also connected.
Directly controls 16 indoor units in the network without extra communication module.
If an indoor unit is being operated by its own control group, it can be inquired and displayed on the operation status.
Remote shield function.
Timer function.
Weekly Timer Function.
Model Name CE50-24/EPower Supply 220V~240V, 50/60HzDimensions (HxWxD) (mm) 120x120x62Weight (g) 391
Operating Mode Display (AUTO, COOL, DRY, FAN, HEAT)
Fan Speed Display (HIGH, MID, LOW, AUTO)
Error/Child Lock/Lock Display
Environmental Temperature /COM # Display
On-line or Selected Indoor Unit No. Display
Operation Mode Setting Button (COOL, DRY, FAN, HEAT)
Fan Speed/Swing Setting
Set Temperature/Timer Setting Button
On/Off Button
Timer/Clock Setting Button
Current Day of Week and Time Display
Shield Status Display (From long distance)Setting Temperature / NO. of Indoor Unit Display
Timer Display
Indoor Unit NO. / Week Selecting
Shield Setting Button
Central Control Setting
Max 16
Serial 1 (multirequency)Serial 2 (multirequency)
Serial 3 (multirequency)
played
54
CENTRALIZED CONTROLLERCE51-24/E(M)
Clock setting.
Error alarm and error code display
Single/Group/Center Control (including weekly timer setting, shield setting, etc)
64 communication modules can be connected and 1024 sets of indoor units can be controlled.
Model Name CE51-24/E(M)Power Supply 220V~240V, 50/60HzDimensions (HxWxD) (mm) 185x131x68Weight (g) 557
Inquire and control the ON/OFF, operation mode, set temperature, fan speed, swing state, etc. of indoor unit.
Automatically detect and display the status of online region and indoor unit (including operation mode, set temperature, fan speed, swing, weekly timer, shield, etc).
Long distance shield function.
Up to 1km communication wires without repeaters.
Error Display
Current Region No. and Unit No. Display (for indoor unit)
Group No. Display
Online Region No. Display*
Online Indoor Unit No. Display
CENTER/GROUP Operating or Setting Display
Day of Week and Time Display
Weekly Timer Display
Direction Key (UP/DOWN/LEFT/RIGHT)
Function Setting Confirmation Button
Grouping Information Setting Button
Back to Superior Menu Button
Center Control Setting Button
Clock Setting Button
Group Control/Setting Button
Cancel Button
All Indoor Units ON/OFF Button
Operation Mode Display
Fan Speed Display (HIGH, MID, LOW, AUTO)
SWING Operation Display
Control Command Sending Display
Shield Status Display
Weekly Timer Display
Set Temperature Display
Room Temperature Display
Swing Operation Setting Button
Temperature Setting Button
Operation Mode Setting Button
Shield Setting Button
ON/OFF Button
Timer Setting or Inquiring Button
Fan Speed Setting Button
Max 64
Communication Module
Communication Module
Communication Module
Max 16 Max 16 Max 16
* All indoor units connected by one communication module are automatically distributed in one region.
55
IR RECEIVER & KEY-CARD CONTROL BOARDJS01 / MK03
) IR receiverJS01
It is applicable to INV duct type indoor unit and equipped with LED lamp for status indication and infrared remote control function.
) Key-card Control BoardMK03
This direction control board is only suitable for INVENTOR multi-variable (INV) indoor unit with gate-control function.
The AC will operate after plugging in the gate-control card and stop operating after pulling out the card.
Upon pulling out the card in order to stop the unit, the running states of the unit will be memorized.
After plugging in the card, the unit will be under standby state or resume running according to settings.
The AC will operate when the customer plugs in the card and automatically stop when he pulls out the card. This ensures that the unit will turn off after people leave the room and that energy will be saved.
Model Name MK03Power Supply 220V~240V, 50/60Hz or DC5V~24V (Supplied by the indoor unit)Dimensions (HxWxD) (mm) 73x73x36Weight (g) 65
LED Lamp
Signal Receiver: it is used for receiving command sent from remote controller
Heating ON/OFF and Cooling ON/OFF
Model Name JS01Power Supply DC5V (Supplied by the indoor unit)Dimensions (HxWxD) (mm) 120x70x58.5Weight (g) 172
56
COMMUNICATION MODULEME30-00/E2
) Functions The communication module (ME30-00/E2) is used for transforming and transmitting
signals of the computer and the air conditioning system. It acts as a communication controller.
Modbus protocol and RS485 interface are adopted so that the unit can be connected to users BMS system and other net-works.
Lots of monitoring nodes make possible to have as many as 255 units in the same network.
Control of setting parameter is available.
Monitoring of operation state is available.
Monitoring of malfunction state is available.
Model Name ME30-00/E2Power Supply 220V~240V, 50/60HzDimensions (HxWxD) (mm) 185x131x68Weight (g) 557
Unit
9~12V DC 800mA
POWER
Power Indicator (Red)
Communication Indicator (Green)
PC or COM2 of Other Module
RS485 Interface
57
COMMISSIONING PROGRAMText Parser
) Brief introduction This software receives data from the INV system through local COM port or network (both internet and LAN are suitable) and
then analyses these data according to communication protocol.
Running parameters of unit, after analysis, will be displayed and saved in real time. There are two kinds of displaying methods, the text displaying and the curve displaying. The analytic data can be saved in database. Technician and service person can use this software to do commissioning.
Real-time parameter display Curves Analysis
Operating System
Microsoft Windows 2000 Professional (English version / Service pack 4 or later)
Microsoft Windows XP PROFESSIONAL (English version / Service pack 2 or later)
Microsoft Windows Vista Home premium / Business / Enterprise / Ultimate
Microsoft Windows 7 Home premium / Business / Enterprise / Ultimate
64-bit version of Windows are not supported
CPU Intel Pentium / Celeron, AMD Athlon / Duron 1Ghz or higherHDD 4 GB or more of free spaceMemory 512MB or more
58
RS-422/485 RREPEATER (ISOLATED)
Power Supply Input AC 220V~50/60HZ Output 12~30 DC 800mADimensions (HxWxD) (mm) 96 x 100.6 x 25Weight (g) 277
Operation Indication LEDs
) FunctionsRs-422/485 repeater (isolated) is used to amplify the communication signal when the quantity of communication modules in the network is more than 30, or communication distance is longer than 800m.
Power
RS-422/485
RS-422/585
Maximum 30 Nos. of module between two repeaters
Maximum cable length between two repeaters is 800m
59
) FunctionsRS232-RS485 opt electronic isolated converter is used for converting the signal between computer / BMS System (RS232) and INVENTOR Air Conditioning Systems (RS485).
Power Supply Input AC 220V~50/60HZ Output 12~30 DC 800mADimensions (HxWxD) (mm) 96 x 100.6 x 25Weight (g) 263
Operation Indication LEDs
RS-422/485
PowerRS-232
RS-232 TO RS-422/485CONVERTER (ISOLATED)
60
INVENTOR AC EUDEMON2009 PC SUIT) Brief introduction of INVENTOR AC Eudemon 2009INVENTOR AC Eudemon 2009 is the latest solution for controlling, monitoring and management of INVENTOR central air condi-tioning systems with your PC.
Maximum Connectable Systems/ Outdoor Units: 255 Maximum Connectable Indoor Units (INV System): 4,000 Maximum Control Distance: 5,600m (Standard distance 800m & extendable to 5.6km) Compatible Systems: INV System, Centrifugal Chiller, Water-cooled screw chiller, Air-Cooled screw chiller,
Air-cooled scroll chiller, etc.
) System schematic planINVENTOR AC Eudemon 2009 Management System/BMS Network Schematic Plan
Note:
In a RS485 Network, different type of systems cannot be connected.
User can only choose either INVENTOR AC Eudemon 2009 or BMS (Modbus) to manage the Air-conditioner system.
Personal Computer
BMS SystemINVENTOR AC Eudemon 2009
Serial Port
Max 255
Convertor
RS485 Network Protocol (Modbus)
More AC Units
Max 255
Communication Module n
Communication Module 1
Communication Module 255
Max 16 Max 16 Max 16
009009
61
) Functions of INVENTOR AC Eudemon 2009 Air Conditioning System running status / error information checking. Air Conditioning System Operation Parameter setting. Multi User Management with different authorized levels. Intelligent Timer with simplified schedule management. Multi Serial port and Multithreading Monitoring. Automatic Detection enables quick monitoring even if the user is not familiar with the concept of equipments, protocol and
models, etc.
Vivid network plan helps the easy understanding of the physical structure of the air conditioning system. Vivid location plan helps easy management of the air conditioning system.
) Functions of INVENTOR AC Eudemon 2009
) Requirement of PC for INVENTOR AC Eudemon 2009
Model name INVENTOR AC Eudemon 2009 FE30-00/A(M)
ContentINVENTOR AC Eudemon 2009 CD-ROM x 1 PCS
RS232-RS485 Opto electronic Isolated Convertor x 1 PCS
Operating System
Microsoft Windows XP PROFESSIONAL (English version / Service pack 2 or later)Microsoft Windows Vista Home premium / Business / Enterprise / UltimateMicrosoft Windows 7 Home premium / Business / Enterprise / Ultimate64-bit version of Windows are not supported
CPU Intel Pentium / Celeron, AMD Athlon / Duron 1Ghz or higher
HDD 10 GB or more of free space
Memory 1GB or more
Software Environment
Internet Explorer 6.0 SpP1 or later (.NET Framework supported)
Microsoft . NET framework 2.0
Microsoft SQL Server 2005 Express
Microsoft Data Access Components (MDAC) 2.8 SP1 or later.
Microsoft Visual C++ 2008 Redistributable SP1
62
PIPING DESIGN PROGRAMINV SELECTOR) BRIEF Introduction INVENTOR INV Selector is a program for doing the piping design of INV VRF systems.
Interface of the main program.
63
) The software provides two ways to output the design Excel summary files: it consists of AutoCAD drawings: Electrical & Communication
the equipment summary, design condition, wiring design of the system. system details and remote monitor detail.
Operating System
Microsoft Windows 2000 Professional (English version / Service pack 4 or later)Microsoft Windows XP Professional (English version / Service pack 2 or later)Microsoft Windows Vista Home premium / Business / Enterprise / UltimateMicrosoft Windows 7 Home premium / Business / Enterprise / Ultimate64-bit version of Windows are not supported
CPU Intel Pentium / Celeron, AMD Athlon / Duron 1Ghz or higher
HDD 4 GB or more of free space
Memory 512MB or more
Software Environment
AutoDesk AutoCAD Excel 2004/2005/2008
Microsoft Office Excel 2000/2003/2007 Professional
Microsoft Visual C++ 2008 Redistributable SP1
Download VRF Selection Software www.inventor.ac/tech_spec
64
ENERGY RECOVERY VENTILATION) Introducing outdoor fresh air and discharging indoor air.
Makes you feel comfortable as in the nature.
) Energy saving Internal heat exchanger performs cooling and heating
exchange between the discharged air and fresh air.
Energy-recovery rate above 70%, high energy saving.
Unique by-pass mode can reduce power consumption of fan motor, in order to prolong lifetime of the heat exchanger core.
By the combination of heat exchange mode and by pass mode, the unit load can be reduced about 26% in a year.
0%
20% 26%
Pow
er r
educ
tion
rat
io
Direct fresh air introduction
Independent heat exchange process
Heat exchange combined with
by-pass proccessDischarge airAir Supply
Temp plate
Heat exchange mode By-pass mode
Outdoor air intake
Exchange air
Return air
Supply air
Outdoor air temperature sensor Air supply fan
Air exchange fan Heat exchange elementRoom temperature
sensor
Outdoor air intake
Exchange air
Return air
Supply air
Outdoor air temperature sensor Air supply fan
Air exchange fan Heat exchange elementIndoor air temperature
sensor
Shell
Indoors air inlet
Fresh air outlet
Lug
Indoor air outlet
Fresh air outlet
Electrical box
Heat exchanger
Air filter
arging indoor air
65
Exchanege of humidity (latent heat) The vapour on the side with high humidity is absorbed by hy-
groscopic agent and discharged to the side with low humidity through capillary action of the fibber.
Through heat exchange between the indoor air and fresh air, the internal heat exchanger reduces the fluctuation of indoor temperature. At the same time it prevents from high temperature difference of the supply air, while reducing the operation load of the unit.
Moisture absorption
Move through capillary
Moisture release
Flexible control LED display
Energy saving mode
24h timer
Centralized controller
Weekly timer
Long-distance Monitoring Control (optional)
Low-noise DesignBuild-in low noise ventilation fan.
Fresh air inlet
Insulation material
Indoor air outlet Fresh air Supply
Room air inlet
Fresh air outletIndoor air return
Discharge air duct
Fresh air duct
) High efficiency heat exchangeThe ERV can exchange the latent heat and sensible heat simultaneously, which can adjust temperature and humidity at the same time. It can be widely applied where there is big humidity difference between indoor and outdoor.
Heat exchange (sensible heat) inside the coreHeat is exchanged between discharged air and fresh air, so that the fresh air temperature to come down and be close to the indoor temperature. The feeling of uncomfortable is avoided and meanwhile the load of air conditioning is effectively decreased.
Air Filtration and purification Function Internal air filter keeps the fresh air introduced into room pure and dustless.
The efficient isolation between fresh air duct and discharge air duct ensures pure air supply.
With antibacterial and anti-mildew materials, the heat exchange core is suiting for healthy.
Wide range of models7 models in a range of 350~3000m3/h, which can fit for different spaces and reduce the waste of power. Wide range from 350 to 3000 m3/h, matching with buildings of various structures.
Reliability and easy maintenance The complete unit with non-moving parts except the
fan motor can reliably operate for a long period of time, without frequent maintenance.
Filter and heat exchange core can be easily taken out from the access door for cleaning.
Compact design and easy installation With a minimum height of 360mm, the unit is space saving. It can be installed inside limited ceiling spaces.
) Installation example
66
SPECIFICATIONS) ERV
MODEL HRVQ-D3.5-K HRVQ-D5-K HRVQ-D8-K HRVQ-D10-K Power supply 220 240V, 1Ph, 50Hz Power Input (W) 165 262 400 440
Airflow rate H/M/L m3/h 360/260/210 500/380/300 800/600/480 1000/750/600CFM 212/153/124 294/224/176 471/353/282 588/441/353
Sound pressure level (dB(A)) 37 39 45 46 External static pressure H/M/L Pa 100/80/60 100/80/60 110/85/65 110/85/65 Temperature exchange efficiently H/M/L
% 71/73/75 68/70/72 70/72/74 75/77/79
Enthalpy exchange efficiency Heating (H/M/L) 65/67/68 62/64/65 63/65/67 66/68/70 Cooling (H/M/L) 61/63/65 57/59/61 60/62/64 62/64/65
Dimension (WxDxH) (mm) 800x879x306 800x879x306 832x1016x380 832x1016x380 Net weight (Kg) 45 45 57 57
MODEL HRVQ-D15-M HRVQ-D20-M HRVQ-D30-M Power supply 380~415V 3N~50Hz Power Input (W) 600 950 2800
Airflow rate m3/h 1500 2000 3000CFM 882 1176 1176
Sound pressure level (dB(A)) 48 50 54 External static pressure Pa 150 150 220 Temperature exchange efficiently
%73 71 70
Enthalpy exchange efficiency Heating 65 62 62 Cooling 60 58 58
Dimension (WxDxH) (mm) 1210x1215x452 1210x1215x452 1340x1550x572 Net weight (Kg) 100 100 240
67
CONNECTION BRANCHES) Modular Outdoor ) Indoor Unit Y-Type
Unit Branch Joint Branch Joint
Gas Pipe Gas Pipe
Liquid Pipe Liquid Pipe
Modular Outdoor Unit Branch Joint
Configuration
Indoor Unit Y-Type Branch Joint
Model Name Configuration
ML01R 22.4 X 96ML02R 96 < X
Model Name Configuration
FQ01A/A X 20.0FQ01B/A 20.0 < X 30.0FQ02/A 30.0 < X 70.0FQ03/A 70.0 < X 135.0FQ04/A 135.0 < XFQ01Na/A X 5.6FQ02Na/A 5.6 < X 22FQ03Na/A 22 < X 30FQ04Na/A 30 < X 68FQ05Na/A 68 < X 96FQ06Na/A 96 < X 135FQ07Na/A 135 < X
For more technical information download the technical files
www.inventor.ac/tech_spec
No 1
www.inventor.ac
for the compressor and for all parts of the unit
ec
ecal informmamamaatititiononon dd dowownlnnlnlnloaoaoaao ddd the te
.inventor.ac/tech_spe
ALL UNITS ARE AVAILABLE FROM OUR SELECTED NETWORK OF AIR CONDITIONING PROFESSIONALS