 User Manual  Waterproof Price Computing Scale Y SP  ©EXCELL PREC ISION CO., L TD. 2013 . All rights reserved worldw ide. The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

201305020846435 g Ty 8 j

Embed Size (px)

Citation preview

Page 1: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 1/15

 

User Manual Waterproof PriceComputing Scale

YSP 

 ©EXCELL PRECISION CO., LTD. 2013 . All rights reserved worldwide.

The information contained herein is the property of EXCELL PRECISION CO., LTD. and issupplied without liability for errors or omissions. No part may be reproduced or usedexcept as authorized by contract or other written permission. The copyright and theforegoing restriction on reproduction and use extend to all media in which the informationmay be embodied.

Page 2: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 2/15

 

1

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

TABLE OF CONTENTS

INSTRUCTION FOR USE ......................................................................................................2

PREPARATION BEFORE USING...........................................................................................3

CHAPTER 1 PRODUCT INTRODUCTION.............................................................................4

1-1 FEATURE ........................................................................................................................41-2 SPECIFICATION ................................................................................................................41-3 ERROR MESSAGES ..........................................................................................................51-4 SCREEN DISPLAY.............................................................................................................51-5 POWER SUPPLY...............................................................................................................6

CHAPTER 2 KEYBOARD FUNCTION ...................................................................................7

CHAPTER 3 OPERATION INSTRUCTION ............................................................................83-1 INTERNAL VALUE DISPLAY MODE.......................................................................................83-2 SETTING UP BACKLIGHT MODE (OPTION)............................................................................83-3 SETTINGS OF PRICING UNIT..............................................................................................83-4 EXTERNAL WEIGHT CALIBRATION ......................................................................................93-5 EXTERNAL WEIGHT FACTORY DEFAULT SETTING ................................................................9

CHAPTER 4 FUNCTION SETTING......................................................................................10

4-1 F3 ⇒ STABILIZATION (ONE OF JUDGEMENT CONDITIONS) ⇒ READING TIMES ......................12

4-2 F4 ⇒ STABILIZATION (ONE OF JUDGMENT CONDITIONS) ⇒ RANGE.....................................12

4-3 F5 ⇒CLEAR UNIT PRICE IMMEDIATELYAFTER ..........................................................134-4 F6 ⇒ SWITCHING-ON UNIT MODE SETTING .....................................................................13

APPENDIX 1 7-SEGMENT DISPLAY CHARACTERS..........................................................14

Page 3: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 3/15

 

2

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Instruction for Use1. In order to prevent the scale from dust and static electricity, please fix the dustproof

cover on the scale with double-sided adhesive.

2. Please keep the scale in a cool and dry place. Do not store at high temperatures or

damp places.

3. Please keep the scale clean and free from insect infestation.4. To avoid impact and it is to be used under designated pressure (the weight put on

the platter can not exceed the maximum capacity of the scale).

5. If the scale is not going to be used for some time, please clean it and store it in a

plastic bag in dry condition. A desiccant sachet may be included to prevent moisture

build up. The scale should be recharged every 3 months to prevent failure of the

internal rechargeable battery.

6. The commodity should be placed in the center of platter for accurate weighing. The

dimension of the weighted commodity should not exceed the dimension of platter.

7.

Thank you for purchasing Price Computing Scale. In order to

operate smoothly, to last the durability, and to reduce the chance of

breakdown for this product, please read this Manual carefully.

Please do not use yourhand and sharp thingsto touch the waterprooffilm, in order to protectthe scale.

Page 4: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 4/15

 

3

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

8

9

Preparation Before Using1. Put the scale on a firm level surface free for accurate weight readings. Adjust the four

leveling feet to get the leveling bubble at the centre of circle.

2. Scale must be used under a stable temperature and stable air flow. Avoid direct

sunlight onto the scale or near the exhaust port of ventilating system. 3. Scale must be used under individual socket to avoid the interference of other

electric appliances.

4. Remove any weight that might be on the platter before the scale is switched on.

5. Please note that when or symbol appears on the screen, the scale

needs to be recharged.

If you want, you can use thefour screws to lock the platterso that it will be more firm.

When you lock ,please followthe order “1→2→3→4”

1

2

3

4

Please push the clip to takeoff the dust cover to clean

push

Page 5: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 5/15

 

4

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Chapter 1 Product Introduction

1-1 Feature

  Sealed waterproof silica gel strip blocks water from infiltrating into the scale.

  Surrounded by waterproof grade sheeting to ensure the water free.

  1/3,000~1/6,000 display resolution available.

  Aluminum frames coated with anti-corrosion treatment for longer lifespan.

  Stainless steel made feet and platter for anti-rusted.

  LCD display with LED Backlight makes readings clear and readable at night.

  High speed of 24bits AD fast reacts and shortens the weighing operation duration.

  Selectable units: Kilogram (kg), gram (g), ounce (oz), and pound (lb) weighing units

available.

  Built-in rechargeable battery can be easily replaced.

  Vertical placement design battery prevents from electrolyte leakage, and makes more

safety and durable.

  Low power indication and auto power off.

  Well-designed protection point for transportation.

  Securable platter with screws at users' needs.

1-2 SpecificationMODEL CAPACITY DIVISION (single range) DIVISION (multi-range)

1g 0kg~3kg/1gYSP-6 6kg

2g 3kg~6kg/2g

2g 0kg~6kg/2gYSP-15 15kg

5g 6kg~15kg/5g5g 0kg~15kg/5g

YSP-30 30Kg10g 15kg~30kg/10g

Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F)

Dimensins: 250.4 x 144 x 313 mm ( W x H x D) 

!eig"t # t"e s$ale: Aro!" 3kg 

Page 6: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 6/15

 

5

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

1-3 Error Messages⇒ The weight value is over 9 division of maximum capacity.

⇒ Zero value above 10% full scale.

⇒ Zero value below 10% full scale.

⇒ The internal value is over 350,000.

⇒ The internal value is below 80,000.

- - - - - ⇒If the negative weight is over 20 divisions and there is no T or PT, the display

shows “- - - - - -”

1-4 Screen DisplayWEIGHT UNIT PRICE

→0←    $/kg. . . . . .  . . . . . . 

NET  

M+   . . . . . . 

TOTAL PRICE  $

Display Column 1. Weight6 digits in total display the weight on platter.

The left digit is able to display the negative symbol.

144mm

313mm

250.4mm

Page 7: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 7/15

 

6

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

2. Unit Price6 digits in total display the unit price of objects on platter.The decimal point floats two digits.

3. Total Price6 digits in total display the total price of the objects on platter or the accumulation. 

Symbol Display

1. Z  : “Zero” indication.

2. T : “Tare” indication.

3. M+  : “Accumulation” indication.

4. :  Low battery.

1-5 Power Supply 

Power Selection 

1. 6 V / 4 Ah Rechargeable battery

2. 110 / 220 V ±15 % AC Main power 

Recharge Voltage 

1. AC 110 V +10%, -15%

2. AC 220 V +10%, -15%

Power Consumption29mA (system+L/C;no backlight,single display) about 138 hours

29mA (system+L/C;no backlight,dubble display) about 138 hours

33mA (system+L/C;backlight, single display) about 121 hours

41mA (system+L/C;  backlight,dubble display) about 90 hours

Low Power Alarm

When the ( ) symbol keeps flashing on the left down corner of the display, it needcharging.

 The indicator will turn off automatically after 5 ~ 10 hours (approximately 1 ~ 2 hours

with backlight on), when the low battery warning symbol shows up. The indicatormust be fully charged, before operating again.

 When the low battery warning symbol shows up, please recharge the indicator

immediately for fear of weight instability.

Page 8: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 8/15

 

7

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Chapter 2 Keyboard Function

0 ~ 9 : Number key. Press the keys to input the numbers (0 ~ 9) and to set unitprice.

CE : Press the key to clear the old unit price and then input the new one if you

would like to change the unit price (If the unit price has been input for 3seconds, you can input the new one immediately).

1T1  : Press the key to deduct the containers’ weight and the symbol “◄” in Weight

will appear.

1Z1  : Weight return to zero

1. 1  : Press this key one time, the DECIMAL POINT is available. Press this keytwo times with number key 1, 2, 3 or 4, PRICING UNIT function is available.

00 : Press this key to enter “00”

Q’TY : When there is more than one piece of the same item, such as cans whichare priced by quantity, input the unit price first and then press Q’TY to enterthe number of items (input an integer no more than 999). The total amountwill be shown in TOTAL PRICE (as same as the calculator’s multiply). At that

moment, please press +  to store it in accumulation.

1+1  : Input unit price in the UNIT PRICE, then press +  to memorize the sum.

M+ : After the number on TOTAL PRICE is stable, press M+ to memorize thesum.

MR : If there is accumulation data in memory, please press MC continually todisplay the last 99 data.

MC : When there is accumulation data in memory (accumulation symbol “◄”displays in TOTAL PRICE), press this key to clear all accumulation data, andaccumulation symbol “◄” disappears.

CH : Press CH , then total price disappears in TOTAL PRICE. Please press

the payment of customer, and the change displays in the UNIT PRICE.

20key keyboard

7 8 9 QTY

4 5 6 + MR

1 2 3 CH MC

0 . CE Z T

M+

Page 9: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 9/15

 

8

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Chapter 3 Operation Instruction

3-1 Internal Value Display Mode Press Z  key, when the display show “

 

” ,then, press CE  key

immediately. The display will show internal value. Press 0  to exit the internal

value mode and return to the weighing mode.

3-2 Setting up Backlight Mode (option)

<Method 1> 

Press Z  key, the display will show “

 

” ,then press 4  key rightaway. It is “auto-backlight mode”.

Press Z  key, the display will show “

 

”, then press 5 key rightaway.It is “backlight-off mode”. 

<Method 2> 

Press 0  key for 2 seconds, the beeper will beep …three times.

The scale will change to backlight mode⇒ 

“Auto-backlight mode” or “backlight-off mode”. 

Auto-backlight mode 

When there is a weight on the pan which weight is over 10d or pressing any keys,

the backlight will be on. After back to zero for 10 desonds (the weight is under

10d,), backlight will be off 

  The scale will keep the auto-backlight mode after the next bootup, if the

auto-backlight mode is set before last power-off.

3-3 Settings of Pricing Unit Selecting the pricing unit: 

Double press key, the display will show the current pricing unit: 

!EI%&T 'NIT PICE

*+  ,.g

NET

M/

TOTAL PICE  ,

Page 10: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 10/15

 

9

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

 Press 1 ~ 6 to select pricing units. The scale will be back to weighing & price mode.The display will show the symbol indication “◄” for the request pricing unit.

1⇒ kg 2⇒ 100g 3⇒ HK catty

4⇒ tl.T 5⇒ lb 6⇒ oz

If the price unit“

lb”

is seleteced, the displaying will show three symbols“3”

.If the price unit“oz”is selected, the displaying will not show any symbol“3”.

3-4 External Weight Calibration

Steps:  1. Make sure the scale backs to zero and is in “kg” mode.

2. Press MC  key and do not release, the then press .  key to show

“ ” , the weight display “ . ” kg .

3. Release two keys.

4. Key-in pre-calibration weight, the display will show “pre-calibration” of weight

value in flash. Place full weight(s) on the pan. When the scale is stable,

take off the weight(s) from the pan. The calibration finished.

3-5 External Weight Factory Default Setting

To Return to the factory setting, hold MC key and press CE key.

After buzzer beep sound, release two keys.

The scale will return to factory setting.

Page 11: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 11/15

 

10

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

pressTkey 

Chapter 4 Function Setting

Press MC key do not release, and turn power on to enter function setting mode.

!EI%&T 'NIT PICE*+ ,.g

NET

M/

TOTAL PICE  ,

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

!EI%&T 'NIT PICE

*+ ,.g

NET

M/TOTAL PICE  ,

3 seconds 

9600 

Rs232 closed pressTkey 

pressTkey 

pressTkey 

⇒reserved

⇒reserved 

⇒reserved 

⇒Stabilization(ReadingTimes)

⇒Stabilization (Range) 

⇒Clear Unit Price

Immediately After

⇒Switching-on Unit ModeSetting 

⇒reserved 

⇒reserved 

⇒reserved 

Page 12: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 12/15

 

11

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Press T key, return to F1 

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

!EI%&T 'NIT !EI%&T

*+ ,.g

NET

M/

0'NTITY

!EI%&T 'NIT !EI%&T

*+ ,.g. . . . . . 

NET

M/. . . . . . 

0'NTITY

!EI%&T 'NIT !EI%&T

*+ ,.g

NET

M/

0'NTITY

pressTkey 

pressTkey 

Unit price reserved 

Close kg

pressTkey 

pressTkey 

pressTkey 

Page 13: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 13/15

 

12

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Press number key from 2 ~ 9 to select 0~9

4-1 F3⇒⇒⇒⇒ Stabilization (One of judgement conditions) ⇒⇒⇒⇒ Reading Times !EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

2~ 9⇒ Reading times “2 ~ 9”

Default setting⇒ 6 times

Press T to go to next setting mode.

Press M+ to save setting values. The scale will count backwards to zero and back toweighing mode from exiting setting mode. 

4-2 F4⇒⇒⇒⇒ Stabilization (One of judgment conditions)⇒⇒⇒⇒ Range

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

Press number key 0 , 1 , 2 , 3 to select 0 ~ 3

0⇒ 1/4 d

1⇒ 1/2 d

2⇒ 3/4 d

3⇒ 1 d

Press T to go to next setting mode.

Press M+ to save setting values. The scale will count backwards to zero and back to

weighing mode from exiting setting mode.

Page 14: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 14/15

 

13

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

4-3 F5⇒⇒⇒⇒Clear Unit Price Immediately After

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

Press number key 0 , 1 to select 0 or 1

0⇒ Unit price reserved.

1⇒ Clear unit price immediately.

(Press to clear unit price immediately in accumulation mode and change mode.)

Press T key to enter the next setting mode.

Press M+ key to save setting values and exit the setting mode. The scale willcount backwards to zero and return to the weighing mode from exiting setting mode.

4-4 F6⇒⇒⇒⇒ Switching-on Unit Mode Setting

!EI%&T 'NIT PICE

*+ ,.g

NET

M/

TOTAL PICE  ,

Use the number key 0 , 1 to select a parameter from 0 or 1

0⇒ The weighing unit remains the prior set mode ** Prior setting mode: If a certain switching-on unit is set, this unit will be the one at

switching on.

If no unit is set, the unit at switching off last time will be the unit atswitching on

1⇒ The weighing unit is as switching on is always “kg”

Press T key to enter the next setting mode.

Press M+ key to save setting values and exit the setting mode. The scale will countbackwards to zero and return to the weighing mode.

Page 15: 201305020846435 g Ty 8 j

8/13/2019 201305020846435 g Ty 8 j

http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 15/15

 

14

EXCELL PRECISION CO., LTD. 

01007021 ZSME100000075

Appendix 1 7-Segment Display Characters

Number Display Letter Display Letter Display

0 A N

1 B O

2 C P

3 D Q

4 E R

5 F S

6 G T

7 H U

8 I V

9 J W

K X

L Y

℃  M Z