User Manual Waterproof PriceComputing Scale
YSP
©EXCELL PRECISION CO., LTD. 2013 . All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD. and issupplied without liability for errors or omissions. No part may be reproduced or usedexcept as authorized by contract or other written permission. The copyright and theforegoing restriction on reproduction and use extend to all media in which the informationmay be embodied.
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 2/15
1
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
TABLE OF CONTENTS
INSTRUCTION FOR USE ......................................................................................................2
PREPARATION BEFORE USING...........................................................................................3
CHAPTER 1 PRODUCT INTRODUCTION.............................................................................4
1-1 FEATURE ........................................................................................................................41-2 SPECIFICATION ................................................................................................................41-3 ERROR MESSAGES ..........................................................................................................51-4 SCREEN DISPLAY.............................................................................................................51-5 POWER SUPPLY...............................................................................................................6
CHAPTER 2 KEYBOARD FUNCTION ...................................................................................7
CHAPTER 3 OPERATION INSTRUCTION ............................................................................83-1 INTERNAL VALUE DISPLAY MODE.......................................................................................83-2 SETTING UP BACKLIGHT MODE (OPTION)............................................................................83-3 SETTINGS OF PRICING UNIT..............................................................................................83-4 EXTERNAL WEIGHT CALIBRATION ......................................................................................93-5 EXTERNAL WEIGHT FACTORY DEFAULT SETTING ................................................................9
CHAPTER 4 FUNCTION SETTING......................................................................................10
4-1 F3 ⇒ STABILIZATION (ONE OF JUDGEMENT CONDITIONS) ⇒ READING TIMES ......................12
4-2 F4 ⇒ STABILIZATION (ONE OF JUDGMENT CONDITIONS) ⇒ RANGE.....................................12
4-3 F5 ⇒CLEAR UNIT PRICE IMMEDIATELYAFTER ..........................................................134-4 F6 ⇒ SWITCHING-ON UNIT MODE SETTING .....................................................................13
APPENDIX 1 7-SEGMENT DISPLAY CHARACTERS..........................................................14
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 3/15
2
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Instruction for Use1. In order to prevent the scale from dust and static electricity, please fix the dustproof
cover on the scale with double-sided adhesive.
2. Please keep the scale in a cool and dry place. Do not store at high temperatures or
damp places.
3. Please keep the scale clean and free from insect infestation.4. To avoid impact and it is to be used under designated pressure (the weight put on
the platter can not exceed the maximum capacity of the scale).
5. If the scale is not going to be used for some time, please clean it and store it in a
plastic bag in dry condition. A desiccant sachet may be included to prevent moisture
build up. The scale should be recharged every 3 months to prevent failure of the
internal rechargeable battery.
6. The commodity should be placed in the center of platter for accurate weighing. The
dimension of the weighted commodity should not exceed the dimension of platter.
7.
Thank you for purchasing Price Computing Scale. In order to
operate smoothly, to last the durability, and to reduce the chance of
breakdown for this product, please read this Manual carefully.
Please do not use yourhand and sharp thingsto touch the waterprooffilm, in order to protectthe scale.
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 4/15
3
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
8
9
Preparation Before Using1. Put the scale on a firm level surface free for accurate weight readings. Adjust the four
leveling feet to get the leveling bubble at the centre of circle.
2. Scale must be used under a stable temperature and stable air flow. Avoid direct
sunlight onto the scale or near the exhaust port of ventilating system. 3. Scale must be used under individual socket to avoid the interference of other
electric appliances.
4. Remove any weight that might be on the platter before the scale is switched on.
5. Please note that when or symbol appears on the screen, the scale
needs to be recharged.
If you want, you can use thefour screws to lock the platterso that it will be more firm.
When you lock ,please followthe order “1→2→3→4”
1
2
3
4
Please push the clip to takeoff the dust cover to clean
push
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 5/15
4
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Chapter 1 Product Introduction
1-1 Feature
Sealed waterproof silica gel strip blocks water from infiltrating into the scale.
Surrounded by waterproof grade sheeting to ensure the water free.
1/3,000~1/6,000 display resolution available.
Aluminum frames coated with anti-corrosion treatment for longer lifespan.
Stainless steel made feet and platter for anti-rusted.
LCD display with LED Backlight makes readings clear and readable at night.
High speed of 24bits AD fast reacts and shortens the weighing operation duration.
Selectable units: Kilogram (kg), gram (g), ounce (oz), and pound (lb) weighing units
available.
Built-in rechargeable battery can be easily replaced.
Vertical placement design battery prevents from electrolyte leakage, and makes more
safety and durable.
Low power indication and auto power off.
Well-designed protection point for transportation.
Securable platter with screws at users' needs.
1-2 SpecificationMODEL CAPACITY DIVISION (single range) DIVISION (multi-range)
1g 0kg~3kg/1gYSP-6 6kg
2g 3kg~6kg/2g
2g 0kg~6kg/2gYSP-15 15kg
5g 6kg~15kg/5g5g 0kg~15kg/5g
YSP-30 30Kg10g 15kg~30kg/10g
Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F)
Dimensins: 250.4 x 144 x 313 mm ( W x H x D)
!eig"t # t"e s$ale: Aro!" 3kg
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 6/15
5
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
1-3 Error Messages⇒ The weight value is over 9 division of maximum capacity.
⇒ Zero value above 10% full scale.
⇒ Zero value below 10% full scale.
⇒ The internal value is over 350,000.
⇒ The internal value is below 80,000.
- - - - - ⇒If the negative weight is over 20 divisions and there is no T or PT, the display
shows “- - - - - -”
1-4 Screen DisplayWEIGHT UNIT PRICE
→0← $/kg. . . . . . . . . . . .
NET
M+ . . . . . .
TOTAL PRICE $
Display Column 1. Weight6 digits in total display the weight on platter.
The left digit is able to display the negative symbol.
144mm
313mm
250.4mm
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 7/15
6
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
2. Unit Price6 digits in total display the unit price of objects on platter.The decimal point floats two digits.
3. Total Price6 digits in total display the total price of the objects on platter or the accumulation.
Symbol Display
1. Z : “Zero” indication.
2. T : “Tare” indication.
3. M+ : “Accumulation” indication.
4. : Low battery.
1-5 Power Supply
Power Selection
1. 6 V / 4 Ah Rechargeable battery
2. 110 / 220 V ±15 % AC Main power
Recharge Voltage
1. AC 110 V +10%, -15%
2. AC 220 V +10%, -15%
Power Consumption29mA (system+L/C;no backlight,single display) about 138 hours
29mA (system+L/C;no backlight,dubble display) about 138 hours
33mA (system+L/C;backlight, single display) about 121 hours
41mA (system+L/C; backlight,dubble display) about 90 hours
Low Power Alarm
When the ( ) symbol keeps flashing on the left down corner of the display, it needcharging.
The indicator will turn off automatically after 5 ~ 10 hours (approximately 1 ~ 2 hours
with backlight on), when the low battery warning symbol shows up. The indicatormust be fully charged, before operating again.
When the low battery warning symbol shows up, please recharge the indicator
immediately for fear of weight instability.
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 8/15
7
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Chapter 2 Keyboard Function
0 ~ 9 : Number key. Press the keys to input the numbers (0 ~ 9) and to set unitprice.
CE : Press the key to clear the old unit price and then input the new one if you
would like to change the unit price (If the unit price has been input for 3seconds, you can input the new one immediately).
1T1 : Press the key to deduct the containers’ weight and the symbol “◄” in Weight
will appear.
1Z1 : Weight return to zero
1. 1 : Press this key one time, the DECIMAL POINT is available. Press this keytwo times with number key 1, 2, 3 or 4, PRICING UNIT function is available.
00 : Press this key to enter “00”
Q’TY : When there is more than one piece of the same item, such as cans whichare priced by quantity, input the unit price first and then press Q’TY to enterthe number of items (input an integer no more than 999). The total amountwill be shown in TOTAL PRICE (as same as the calculator’s multiply). At that
moment, please press + to store it in accumulation.
1+1 : Input unit price in the UNIT PRICE, then press + to memorize the sum.
M+ : After the number on TOTAL PRICE is stable, press M+ to memorize thesum.
MR : If there is accumulation data in memory, please press MC continually todisplay the last 99 data.
MC : When there is accumulation data in memory (accumulation symbol “◄”displays in TOTAL PRICE), press this key to clear all accumulation data, andaccumulation symbol “◄” disappears.
CH : Press CH , then total price disappears in TOTAL PRICE. Please press
the payment of customer, and the change displays in the UNIT PRICE.
20key keyboard
7 8 9 QTY
4 5 6 + MR
1 2 3 CH MC
0 . CE Z T
M+
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 9/15
8
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Chapter 3 Operation Instruction
3-1 Internal Value Display Mode Press Z key, when the display show “
” ,then, press CE key
immediately. The display will show internal value. Press 0 to exit the internal
value mode and return to the weighing mode.
3-2 Setting up Backlight Mode (option)
<Method 1>
Press Z key, the display will show “
” ,then press 4 key rightaway. It is “auto-backlight mode”.
Press Z key, the display will show “
”, then press 5 key rightaway.It is “backlight-off mode”.
<Method 2>
Press 0 key for 2 seconds, the beeper will beep …three times.
The scale will change to backlight mode⇒
“Auto-backlight mode” or “backlight-off mode”.
Auto-backlight mode
When there is a weight on the pan which weight is over 10d or pressing any keys,
the backlight will be on. After back to zero for 10 desonds (the weight is under
10d,), backlight will be off
The scale will keep the auto-backlight mode after the next bootup, if the
auto-backlight mode is set before last power-off.
3-3 Settings of Pricing Unit Selecting the pricing unit:
Double press key, the display will show the current pricing unit:
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 10/15
9
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Press 1 ~ 6 to select pricing units. The scale will be back to weighing & price mode.The display will show the symbol indication “◄” for the request pricing unit.
1⇒ kg 2⇒ 100g 3⇒ HK catty
4⇒ tl.T 5⇒ lb 6⇒ oz
If the price unit“
lb”
is seleteced, the displaying will show three symbols“3”
.If the price unit“oz”is selected, the displaying will not show any symbol“3”.
3-4 External Weight Calibration
Steps: 1. Make sure the scale backs to zero and is in “kg” mode.
2. Press MC key and do not release, the then press . key to show
“ ” , the weight display “ . ” kg .
3. Release two keys.
4. Key-in pre-calibration weight, the display will show “pre-calibration” of weight
value in flash. Place full weight(s) on the pan. When the scale is stable,
take off the weight(s) from the pan. The calibration finished.
3-5 External Weight Factory Default Setting
To Return to the factory setting, hold MC key and press CE key.
After buzzer beep sound, release two keys.
The scale will return to factory setting.
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 11/15
10
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
pressTkey
Chapter 4 Function Setting
Press MC key do not release, and turn power on to enter function setting mode.
!EI%&T 'NIT PICE*+ ,.g
NET
M/
TOTAL PICE ,
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
!EI%&T 'NIT PICE
*+ ,.g
NET
M/TOTAL PICE ,
3 seconds
9600
Rs232 closed pressTkey
pressTkey
pressTkey
⇒reserved
⇒reserved
⇒reserved
⇒Stabilization(ReadingTimes)
⇒Stabilization (Range)
⇒Clear Unit Price
Immediately After
⇒Switching-on Unit ModeSetting
⇒reserved
⇒reserved
⇒reserved
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 12/15
11
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Press T key, return to F1
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
!EI%&T 'NIT !EI%&T
*+ ,.g
NET
M/
0'NTITY
!EI%&T 'NIT !EI%&T
*+ ,.g. . . . . .
NET
M/. . . . . .
0'NTITY
!EI%&T 'NIT !EI%&T
*+ ,.g
NET
M/
0'NTITY
pressTkey
pressTkey
Unit price reserved
Close kg
pressTkey
pressTkey
pressTkey
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 13/15
12
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Press number key from 2 ~ 9 to select 0~9
4-1 F3⇒⇒⇒⇒ Stabilization (One of judgement conditions) ⇒⇒⇒⇒ Reading Times !EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
2~ 9⇒ Reading times “2 ~ 9”
Default setting⇒ 6 times
Press T to go to next setting mode.
Press M+ to save setting values. The scale will count backwards to zero and back toweighing mode from exiting setting mode.
4-2 F4⇒⇒⇒⇒ Stabilization (One of judgment conditions)⇒⇒⇒⇒ Range
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
Press number key 0 , 1 , 2 , 3 to select 0 ~ 3
0⇒ 1/4 d
1⇒ 1/2 d
2⇒ 3/4 d
3⇒ 1 d
Press T to go to next setting mode.
Press M+ to save setting values. The scale will count backwards to zero and back to
weighing mode from exiting setting mode.
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 14/15
13
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
4-3 F5⇒⇒⇒⇒Clear Unit Price Immediately After
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
Press number key 0 , 1 to select 0 or 1
0⇒ Unit price reserved.
1⇒ Clear unit price immediately.
(Press to clear unit price immediately in accumulation mode and change mode.)
Press T key to enter the next setting mode.
Press M+ key to save setting values and exit the setting mode. The scale willcount backwards to zero and return to the weighing mode from exiting setting mode.
4-4 F6⇒⇒⇒⇒ Switching-on Unit Mode Setting
!EI%&T 'NIT PICE
*+ ,.g
NET
M/
TOTAL PICE ,
Use the number key 0 , 1 to select a parameter from 0 or 1
0⇒ The weighing unit remains the prior set mode ** Prior setting mode: If a certain switching-on unit is set, this unit will be the one at
switching on.
If no unit is set, the unit at switching off last time will be the unit atswitching on
1⇒ The weighing unit is as switching on is always “kg”
Press T key to enter the next setting mode.
Press M+ key to save setting values and exit the setting mode. The scale will countbackwards to zero and return to the weighing mode.
8/13/2019 201305020846435 g Ty 8 j
http://slidepdf.com/reader/full/201305020846435-g-ty-8-j 15/15
14
EXCELL PRECISION CO., LTD.
01007021 ZSME100000075
Appendix 1 7-Segment Display Characters
Number Display Letter Display Letter Display
0 A N
1 B O
2 C P
3 D Q
4 E R
5 F S
6 G T
7 H U
8 I V
9 J W
K X
L Y
℃ M Z