© Vektek, April 2019 800-992-0236 www.vektek.com
Rotating unions are a rotary connection, feeding pressure to fixtures while allowing full 360° rotation of the fixture with or without pressure.A machine or independent indexer may do this indexing. Rotating unions allow “live” hydraulic power to be supplied to fixtures during the machining cycle.
Single, dual, quad, 6, 8 and 12 path models are available to fit your application. SAE 6 models are required for major fluid distribution and all remote valve systems. SAE 4 models may be used on double acting systems and small single acting systems where speed of retraction is not critical. Most units may be either man i fold mounted or used with standard fittings. Slip Rings are electrical rotary connections which can be operated with some models below.
The leak free design eliminates the need for a drain or vent line required by standard industrial models. This feature also reduces the demand for pressure present in industrial models that can cause pump cycling.
All units include internal bearings to increase lifeunder loaded applications. Quad path models are often installed in machine doors to feed two in de pen dent dual path models on fixtures, making VektorFlo® the choice for all of your machine clamping needs. Integral mounting holes and multiple plumbing options make VektorFlo® designs easier to use than specialized larger in dus tri al model.
Solidly bolt into place either the shaft or the housing component of the rotary union; not both. Mount the opposing component using a cableway or similar anti-rotation device to allow for some movement in the event of misalignment.
Standard Features Single, Dual, Quad, 6, 8 and 12 Flow Path Models
Maximum RPM at Various Pressures with Petroleum Based FluidsModel No. Configuration 500 psi 1000 psi 2000 psi 3000 psi 4000 psi 5000 psi
32-1261-00 Single Path 915 460 230 150 115 9032-1241-00 Single Path 460 230 115 75 60 5032-1261-0132-1461-41 Single Path 380 190 95 65 50 4032-2242-02
Dual Path 380 190 95 65 50 4032-2262-0232-2242-0332-2262-0332-4244-01 Quad Path 380 190 95 65 50 4032-4264-0132-6246-00 6 Path 180 140 80 50 40 3032-6246-0132-6246-00 6 Path with
Slip Ring100 100 80 50 40 3032-6246-01
32-8248-00 8 Path 180 140 80 50 40 3032-8248-0132-8248-00 8 Path with
Slip Ring100 100 80 50 40 3032-8248-01
32-1224-12 12 Path 150 110 60 40 30 2032-1224-1332-1224-12 12 Path with
Slip Ring100 100 60 40 30 2032-1224-13
ILS321200 REV H
Solidly bolt into place either the shaft or the housing component of the rotary union; not both. Mount the opposing component using a cableway or similar anti-rotation device to allow for some movement in the event of misalignment.
Use Vektek'sRotary Union Armfor anti-rotation.(See end of this section)
I-3
Miscellaneous Plumbing
Rotating Unions
www.vektek.com 800-992-0236 © Vektek, April 2019
Operating Parameter Guidelines - Max. Hydraulic Pressure: 5,000 psi - Max. Air Pressure: 200 psi - Max. Vacuum: 28 Hg - Max. Temperature: 400° F - Max. RPM see table page I-3
Single Path Rotating Union NPT Ports
Model No.32-1461-41
Single Path Rotating Union SAE In-Line
Model No.32-1261-00
NOTE: Hoses alone should never be used to control the movement of a rotating union.
Operating Parameter Guidelines - Operating Temperature: 40º-160° F - Max. RPM see table page I-3
Miscellaneous Plumbing
Rotating Union, Single Path
I-4
© Vektek, April 2019 800-992-0236 www.vektek.com
Single Path DimensionsModel No. A B C D E F G H J K L M
32-1241-00 2.36 0.69 SAE 2 0.38 1.30 SAE 4 1.30 0.97 2.25 2.75 1.37 0.39
32-1261-01 2.60 0.97 SAE 2 0.50 1.58 SAE 6 1.44 1.03 2.38 3.00 1.35 0.67
Operating Parameter Guidelines - Operating Temperature Range: 40°-160° F - Max. RPM see table page I-3
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 32 µ in. Ra surface finish.
Adapter cavities generated with a standard SAE port tool.
Input Pressure (psi)
20000
5
10
15
20
25
0 1000 3000 4000 5000
Rota
tion
al To
rqu
eR
esi
sta
nce
(in
-lb
)
Input Pressure (psi)050
100150200250300350400450500
0 1000 2000 3000 4000 5000
Speed
(rp
m)
Operating Limits
ILS321204 REV D
K
DE
MB L
.13
A
H
G
45.0
.375
Locator Hole.218 Thru Base
ILS321203 REV N
C Port Pluggedat assembly. Tomanifold mount,order adapter30-8711-23 &discard plug.
4X Counterbored& Drilled for1/4 Cap Screwson J Bolt Circle
2X Counterbored& Drilled for1/4 Cap Screwson J Bolt Circle
F
F 2X 5/16-18 UNC
.50
BasePort
J Bolt Circle
Single Path Rotating Unions
I-5
Miscellaneous Plumbing
Rotating Union, Single Path
www.vektek.com 800-992-0236 © Vektek, April 2019
Dual Path DimensionsModel No. A B C D E F G H J K L M N P Q
Adapter Model No. 30-8711-23 is needed for manifold mounting. Order Separately.32-2242-02 2.97 2.28 1.56 1.06 0.50 0.28 SAE 2 3.00 1.51 1.156 1.25 SAE 4 2.312 1.46 0.77
32-2262-02 3.34 2.56 1.73 1.13 0.63 0.38 SAE 2 3.47 1.82 1.375 1.50 SAE 6 2.750 1.68 0.84
Models 32-2242-03 and 32-2262-03 are not adaptable for manifold mounting.32-2242-03 3.06 2.38 1.66 1.16 0.60 0.39 SAE 4 3.00 1.51 1.156 1.25 SAE 4 2.312 1.46 0.87
32-2262-03 3.34 2.56 1.73 1.13 0.63 0.47 SAE 6 3.47 1.82 1.375 1.50 SAE 6 2.750 1.68 0.85
Operating Parameter Guidelines - Operating Temperature: 40°-160° F - Air may be run in any available passage - Max. RPM see table page I-3
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 32 µ in. Ra surface finish.
A
N
D
2XE
2X FP P
4X L
H
K
J
B
C
45
.375
Locator Hole.218 .41
4X90
Q
2X .1252X R.34
ILS321205 REV R
MM
2X G Ports- These ports are plugged at assembly.For manifold mounting models 32-2242-02 and
32-2262-02, order two each adapter 30-8711-23and discard the plugs. Model numbers ending in
-03 are not manifold mountable. See Note.
4X 1/4 CapscrewMounting Holes
M
M
2X 3/8-16 UNC .50
2X 5/16 Cap Screw Mounting Holes
M
Base Port B
Base Port ABOTTOM VIEW
050
100150200250300350400
0 1000 2000 3000 4000 5000
Speed
(rp
m)
Input Pressure (psi)
Operating Limits
ILS321212 REV B
020406080
100120140
0 1000 2000 3000 4000 5000Rota
tion
al To
rqu
eR
esi
sta
nce
(in
-lb
)
Input Pressure (psi)
32-2262-02 &32-2262-03
32-2242-02 &32-2242-03
NOTE: Torque requirements may vary depending on port configuration and pressure run through ports. Testing of your specfic application may be required.
Dual Path Rotating Unions
Miscellaneous Plumbing
Rotating Union, 2 Path
I-6
© Vektek, April 2019 800-992-0236 www.vektek.com
Quad Path Dimensions
Model No. A B C D E F G H J K L M N P Q R
32-4244-01 4.00 2.65 1.65 0.96 0.50 0.52 SAE 2 2.15 3.15 1.56 1.56 SAE 4 1.47 1.81 3.75 0.65
32-4264-01 4.50 3.01 1.81 1.08 0.56 0.52 SAE 2 2.41 3.61 1.69 1.75 SAE 6 1.52 1.94 4.00 0.79
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 32 µ in. Ra surface finish.
Operating Parameter Guidelines - Operating Temperature Range: 40°-160° F. - Max. RPM see table page I-3. - Rotational torque required when no ports pressurized: 50 in-lbs - Max rotational torque required when ports are pressurized to 5,000 psi: 180 in-lbs - Torque requirements may vary depending on port configuration and pressure run through ports. - Testing your specific application may be required. - Air may be run in any available passage.
ILS321213 REV B
507090
110130150170190
0 1000 2000 3000 4000 5000Rot
atio
nal T
orqu
e R
esis
tanc
e (in
-lb)
Input Pressure (psi)*Note: Torque requirements may vary depending on port configuration and pressure run through ports. Testing of your specific application may be required.
050
100150200250300350400
0 1000 2000 3000 4000 5000
Spee
d (r
pm)
Input Pressure (psi)
Operating Limits
AA
B
B
D
4X E
4X F
4XL
4X30
JH
A
B
C
4X P4XN
2XK
2X30
45
Locator Hole.218 .41
.375
4X90
R
4X CBORE.68 .13
ILS321208 REV R
Section A-A
12X M
BodyPort A
BodyPort C
BodyPort D
BodyPort B
4X G These ports are pluggedat assembly. For manifoldmounting, order four each
of adapter 30-8711-23and discard plugs.
Q
2X 3/8-16 UNC .53
4X 1/4 Cap ScrewMounting Holes
Section B-B
Base Port A
Base Port C
Base Port B
BasePortD
BOTTOM VIEW
Quad Path Rotating Unions
I-7
Miscellaneous Plumbing
Rotating Union, 4 Path
www.vektek.com 800-992-0236 © Vektek, April 2019
6 Path Rotary Unions
Model No.
Hydraulic Input
Connection
Electrical Slip Ring Option
Maximum Current/Circuit
MaximumVolts/Circuit
Lead Wire Length
Optional Mounting Flange
Model No.**
OptionalCord Set***
32-6246-00 SAE 4 N/A N/A N/A N/A
93-2620-00
N/A32-6246-00-ES6A SAE 4 6 Circuit 2 Amp 120 VAC 48” 27-6424-0132-6246-00-ES12A SAE 4 12 Circuit 2 Amp 120 VDC 48” 27-6424-02
32-6246-01 O-Ring Face Seal* N/A N/A N/A N/A N/A
32-6246-01-ES6A O-Ring Face Seal* 6 Circuit 2 Amp 120 VAC 48” 27-6424-01
32-6246-01-ES12A O-Ring Face Seal* 12 Circuit 2 Amp 120 VDC 48” 27-6424-02
Operating Parameter Guidelines: - Max. Pressure with or without slip ring: 5,000 psi - Max. Vacuum with or without slip ring: 30 Hg - Max. RPM under vacuum with or without slip ring: contact factory - Max RPM under pressure with or without slip ring, see table on page I-3 - Operating Temperature Range with slip ring 0° - 176° F - Operating Temperature Range without slip ring 0°- 220° F - Air may be run in any available passage
For proper sealing, mating surface should be flat to 0.003 in. with a maximum 32 µ in. Ra surface finish.
* O-Rings furnished: -010, 70A, NBR Part No. 55-2500-01** Optional Mounting Flange includes: - 6 SHCS 1/4-20 x 1/2 Part No. 21- 4100-63- 6 O-Rings - 010, 70A NBR Part No. 55-2500-01- 1 O - Rings - 012, 70A NBR Part No. 39-0020-09 - 1 O-Rings - 013, 70A NBR Part No. 39- 0000-72*** Order cord set separately.
Installation instructions available. Request IS3205 or visit our online catalog for a link to this document.
6 Path Rotating Unions
A
A
1.000 B.C.
2.375 B.C.
3.94
.56
.5030
1.000 B.C.
3.500B.C
6X 60
6X 60 .38 Thru
6.09
.75
1.832X 1.27
2.47 2X 1.27
.875
5X 60
5X 60
45
3X90
30
2.94
(48)
ILS326200 REV J
4X 1/4-20 x.50
1
2
3
4
5
6
6X SAE 4
6X 1/4-20 x.75
6X SAE 4
6X .19 thruoil passage,manifold mountmodels only
2.500 B.C.
Optional Steel Mounting FlangePN 93-2620-00
6X .19 Thruoil passage
6X.26 Thru
SECTION A-A
Optional 6 or 12 Circuit Electrical Slip Ring:-Aluminum Slip Ring Cap-Water Tight Pin Connector-48 in. Lead Wire
Optional 6 or 12 Pinx 32 ft. Cordset-Ordered SeparatelySee Table
Miscellaneous Plumbing
Rotating Union, 6 Path
I-8
© Vektek, April 2019 800-992-0236 www.vektek.com
8 Path Rotating Unions
8 Path Rotary Unions
Model No.
Hydraulic Input
Connection*
Electrical Slip Ring Option
Maximum Current/Circuit
MaximumVolts/Circuit
Lead Wire Length
Optional Flange
Model No.**
Optional Cordset***
32-8248-00 SAE 4 N/A N/A N/A N/A
93-2820-00
N/A32-8248-00-ES6A SAE 4 6 Circuit 2 Amp 120 VAC 48” 27-6424-0132-8248-00-ES12A SAE 4 12 Circuit 2 Amp 120 VDC 48” 27-6424-02
32-8248-01O-Ring Face
Seal*N/A N/A N/A N/A N/A
32-8248-01-ES6AO-Ring Face
Seal*6 Circuit 2 Amp 120 VAC 48” 27-6424-01
32-8248-01-ES12AO-Ring Face
Seal*12 Circuit 2 Amp 120 VDC 48” 27-6424-02
For Proper sealing, mating surface should be flat to 0.003 in. with a maximum 32 µ in. Ra surface finish.
* O-Rings furnished: -009, 70A, NBR Part No. 39-0500-36** Optional Mounting Flange includes: - 8 SHCS 1/4-20 x 1/2 Part No. 21- 4100-63- 8 O-Rings - 009, 70A NBR Part No. 39-0500-36- 1 O-Rings - 012, 70A NBR Part No. 39-0020-09- 1 O-Rings - 013, 70A NBR Part No. 39- 0000-72*** Order cord set separately.
Installation instructions available. Request IS3205 or visit our online catalog for a link to this document.
A
A
.38 Thru8X 45
7.36
.75
1.83 3X 1.27
2.47 3X 1.2722.5
2.94 45
3X90
3.94
.56
.50
7X 45
22.5
3.500B.C.
8X.26
Thru7X 45
8X 45
1.062B.C.
(48)
ILS328200 REV K
4X 1/4-20 .50
2.375 B.C.
8X SAE 4
1
2
3
4
5
6
7
8
8XSAE 4
8X 1/4-20 .75
8X .19 Thruoil passage,manifold mountmodels only
2.500 B.C.
Optional Steel Mounting FlangePN 93-2820-00
8X .19 Thruoil passage Optional 6 or 12 Circuit
Electrical Slip Ring:-Aluminum Slip Ring Cap-Water Tight Pin Connector-48 in. Lead Wire
Optional 6 or 12 Pinx 32 ft. Cordset-Ordered SeparatelySee TableSECTION A-A
Operating Parameter Guidelines: - Max. Pressure with or without slip ring: 5,000 psi - Max. Vacuum with or without slip ring: 30 Hg - Max. RPM under vacuum with or without slip ring: contact factory. - Max. RPM under pressure with or without slip ring, see table on page I-3 - Operating Temperature Range with slip ring 0° - 176° F - Operating Temperature Range without slip ring 0° - 220° F - Air may be run in any available passage
Miscellaneous Plumbing
Rotating Union, 8 Path
I-9
www.vektek.com 800-992-0236 © Vektek, April 2019
12 Path Rotary Unions
Model No.
Hydraulic Input
Connection
Electrical Slip Ring Option
Maximum Current/Circuit
MaximumVolts/Circuit
Lead Wire Length
Optional Flange
Model No.**
Optional Cord Set***
32-1224-12 SAE 4 N/A N/A N/A N/A
93-2120-00
N/A32-1224-12-ES6A SAE 4 6 Circuit 2 Amp 120 VAC 48” 27-6424-01
32-1224-12-ES12A SAE 4 12 Circuit 2 Amp 120 VDC 48” 27-6424-02
32-1224-13O-Ring Face
Seal*N/A N/A N/A N/A N/A
32-1224-13-ES6AO-Ring Face
Seal*6 Circuit 2 Amp 120 VAC 48” 27-6424-01
32-1224-13-ES12AO-Ring Face
Seal*12 Circuit 2 Amp 120 VDC 48” 27-6424-02
For Proper sealing, mating surface should be flat to 0.003 in. with a maximum 32 µ in. Ra surface finish.
12 Path Rotating Unions
* O-Rings furnished: -009, 70A, NBR Part No. 39-0500-36** Optional Mounting Flange includes: - 12 SHCS 1/4-20 x 1/2 Part No. 21- 4100-63 - 12 O-Rings - 009, 70A NBR Part No. 39-0500-36 - 1 O-Rings - 012, 70A NBR Part No. 39-0020-09 - 1 O-Rings - 013, 70A NBR Part no. 39-0000-72*** Order cord set separately.
Installation instructions available. Request IS3205 or visit our online catalog for a link to this document.
A
A
.812
10.80
5.82
3.44
45
1.93 4X 1.27 .72
1.352.57 4X 1.27
11X30
15
30
5X 60
3X90
305X 60
6X 60
2.94
2.375 B.C.
3.000 B.C.
1.562 B.C.
1.062 B.C.
.562
4.437
.50015
4.000B.C.
1.562 B.C.
1.062 B.C.
11X 30
6X 60
ILS3211200 REV K
12X SAE 4
1 3 5 7 9 11
2 4 6 810 12
4X 1/4-20.50
.38 Thru
12X 1/4-20 .75
12 X .19 Thruoil passage,manifold mountmodels only.
12X SAE 4
Optional Steel Mounting FlangePN 93-2120-00
12X.26 Thru
12 X .19 Thruoil passage
SECTION A-A
Optional 6 or 12 Pinx 32 ft. Cordset-Ordered SeparatelySee Table
Optional 6 or 12 Circuit Electrical Slip Ring:-Aluminum Slip Ring Cap-Water Tight Pin Connector-48 in. Lead Wire
Operating Parameter Guidelines: - Max. Pressure with or without slip ring: 5,000 psi - Max. Vacuum with or without slip ring: 30 Hg - Max. RPM under vacuum with or without slip ring: contact factory - Max. RPM under pressure with or without slip ring, see table on page I-3 - Operating Temperature Range with slip ring: 0° - 176° F - Max Operating Temperature Range without slip ring 0°- 220° F - Air may be run in any available passage
Miscellaneous Plumbing
Rotating Union, 12 Path
I-10
© Vektek, April 2019 800-992-0236 www.vektek.com
I-11
3.00
4.10
4.10
3.00
12.2510.50
4.25 3.00
7.50 CLEARANCE 4.884.00 CLEARANCE 3.86
W 7.00
W
2.63
28.66 MAX18.66 MIN
26.71 MAX21.71 MIN
48.00 MAX11.00STANDARD
ILS644000 REV A
For 1/2 Inch BoltTYP
Hose Management
DIMENSIONS FOR YOUR MOUNTING CHOICE
Hose clamp rails
Base Bracket
Mounting DimensionsExtension Bracket
Mounting Dimensions
The Rotary Union Arm is designed to
allow for vertical movement of the
rotary union/tombstone while machining
and during pallet change. Additional
configurations are possible see IS3206.
Allowable Vertical Movement
ID
ID
Additional Rail for Hose Clamp
3.00
4.10
4.10
3.00
12.2510.50
4.25 3.00
7.50 CLEARANCE 4.884.00 CLEARANCE 3.86
W 7.00
W
2.63
28.66 MAX18.66 MIN
26.71 MAX21.71 MIN
48.00 MAX11.00STANDARD
ILS644000 REV A
For 1/2 Inch BoltTYP
Hose Management
DIMENSIONS FOR YOUR MOUNTING CHOICE
Hose clamp rails
Base Bracket
Mounting DimensionsExtension Bracket
Mounting Dimensions
The Rotary Union Arm is designed to
allow for vertical movement of the
rotary union/tombstone while machining
and during pallet change. Additional
configurations are possible see IS3206.
Allowable Vertical Movement
ID
ID
I-11
Miscellaneous PlumbingRotary Union Arm
Reduce cost and hassle of live hydraulic integration of Vektek pumps or continuously connected PO Check industrial pumps. Use on single or dual pallet machines where pallet travels parallel to spindle axis. Telescoping members promote flexibility during installation. Two hose clamp mounting rails included. All clamps and additional rails can be ordered per your requirements (see below). Rotary union interface eliminates premature rotary union failure by preventing the weight of the arm from applying damaging side loads to the rotary union. Rotary Union Arm designed to attach to all Vektek Hydraulic Rotary Unions. Easily customize interface plate to attach most rotary unions.
Model No. Z-Axis Travel Includes64-4050-00 Up to 48 Inches Arm and hose clamp rail
Model No. Includes
93-2000-03 Rail and Mounting Hardware
Each joint contains tapered roller bearings for excellent load holding with smooth actuation. Standard Z-axis travel up to 48 inches, longer travels available. Optional hose clamps available (see below).
Rotary Union ArmAn anti-rotation device for Vektek Rotating Unions
Industry standard T-Slot rail nut mounting.
Model No. ID Hose OD W
35-2003-01 .39 .36 - .43 .4235-2004-01 .50 .47 - .54
2.0935-2005-01 .55 .52 - .5935-2006-02 .68 .65 - .7235-2003-03 .39 .36 - .43 .4635-2004-03 .50 .47 - .54
1.6535-2005-03 .55 .52 - .5935-2006-05 .68 .65 - .72
3.00
4.10
4.10
3.00
12.2510.50
4.25 3.00
7.50 CLEARANCE 4.884.00 CLEARANCE 3.86
W 7.00
W
2.63
28.66 MAX18.66 MIN
26.71 MAX21.71 MIN
48.00 MAX11.00STANDARD
ILS644000 REV A
For 1/2 Inch BoltTYP
Hose Management
DIMENSIONS FOR YOUR MOUNTING CHOICE
Hose clamp rails
Base Bracket
Mounting DimensionsExtension Bracket
Mounting Dimensions
The Rotary Union Arm is designed to
allow for vertical movement of the
rotary union/tombstone while machining
and during pallet change. Additional
configurations are possible see IS3206.
Allowable Vertical Movement
ID
ID
Hose Management
Other clamp sizes available. Contact factory.
Hose Clamps not includedwith Rail (order at left)
3.00
4.10
4.10
3.00
12.2510.50
4.25 3.00
7.50 CLEARANCE 4.884.00 CLEARANCE 3.86
W 7.00
W
2.63
28.66 MAX18.66 MIN
26.71 MAX21.71 MIN
48.00 MAX11.00STANDARD
ILS644000 REV A
For 1/2 Inch BoltTYP
Hose Management
DIMENSIONS FOR YOUR MOUNTING CHOICE
Hose clamp rails
Base Bracket
Mounting DimensionsExtension Bracket
Mounting Dimensions
The Rotary Union Arm is designed to
allow for vertical movement of the
rotary union/tombstone while machining
and during pallet change. Additional
configurations are possible see IS3206.
Allowable Vertical Movement
ID
ID
Allowable Vertical Movement
Extension Bracket
DIMENSIONS FOR YOUR MOUNTING CHOICE
Base Bracket
www.vektek.com 800-992-0236 © Vektek, April 2019
Miscellaneous PlumbingRotary Union Arm
I-12
© Vektek, April 2019 800-992-0236 www.vektek.com
Hoses All VektorFlo® hoses are intended to operate up to
5,000 psi working pressure. End fittings have the largest possible orifice to
reduce restrictions and allow devices to work better. Large hoses are typically used to feed entire fixtures,
medium size hoses are for feeding small fixtures or single devices.
Small hoses are to be used to feed single devicesONLY and are to be con nect ed directly back to a manifold unless used on double acting clamps.
HosesModelNo.
Minimum Bend Radius (in.)
HoseI.D.
HoseO.D. Fitting A Fitting B F
35-1111-08
0.75 0.08 0.227/16-20 Female JIC 37° Swivel
(Single device feed hose)7/16-20 Female JIC 37° Swivel
8 in.35-1111-12 12 in.35-1111-18 18 in.35-1111-24 24 in.35-1111-30 30 in.35-1133-02
1.50 0.19 0.437/16-20 Male Straight Thread
SAE 4 O-Ring Boss7/16-20 Female JIC 37° Swivel
24 in.35-1133-03 36 in.35-1133-05 60 in.35-1446-03
2.50 0.38 0.679/16-18 Male Straight Thread
SAE 6 O-Ring Boss9/16-18 Male Straight Thread
SAE 6 O-ring Boss
36 in.35-1446-05 60 in.35-1446-10 120 in.
Hose Mounting ClipModel No.
Hose ID A B C D
35-2001-00 0.08 0.48 0.36 0.80 0.1335-2003-00 0.19 0.74 0.57 1.10 0.1635-2006-00 0.38 1.04 0.80 1.61 0.22
NOTE: Use of standard rubber hoses and end fittings can hamper the action of many devices due to excessive end fitting restrictions. If you choose to purchase hoses from another supplier, be sure that hose diameters and end fittings are not causing ex ces sive restrictions.
TubingPart No. Description
35-0002-05 1/4 (0.250”) O.D. x 0.049 Thick Wall35-0003-05 3/8 (0.375”) O.D. x 0.065 Thick WallSuggested Center Line Radius 1/4” =0.56 and 3/8” =0.94
I-13
Miscellaneous Plumbing
Hoses & Tubing