8
Polymeric Insulators ENERGY PRODUCTS DIVISION

Insulatorsdecpl.in/Raychem/polymeric_insulators.pdf · 2018. 6. 13. · Corporate Office: Raychem RPG (P) Ltd., RPG House, 463, Dr. Annie Besant Road, Worli, Mumbai-400030 Tel: +91

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • Polymeric

    Insulators

    ENERGY PRODUCTS DIVISION

  • InsulatorsInsulators are devices which are used on electricity supply networks to support, separate or contain

    conductors at high voltages.

    Insulators have the dual functions of mechanically supporting aerial conductors while also providing

    adequate electrical insulation between the energised conductor and the supporting pole or structure.

    Insulators are used in electrical systems and are designed to accept Cantilever or Tension loading.

    Polymeric InsulatorsPolymeric Insulators consists of: A glass fibre reinforced resin core to provide the

    mechanical strength, while resisting the electrical stress

    Elastomer sheds to provide the required creepage and

    stress reduction to with stand the stresses prevailing on the

    system. Two commonly used material are silicone rubber

    and Ethylene Vinyl Acetate(EVA)

    A major advantage of polymeric insulators is an upto 70%

    reduction in weight when compared to porcelain insulators

    which can be used to redesign and bring down the weight of

    the entire structure ensuring cost reductions.

    High strength pultruded

    fibre glass rod

    Field proven

    interfacial sealing

    Non tracking,

    UV resistant

    housing

    Corrosion resistant

    crimped end fittings

    Polymeric Insulator Construction

  • Horizontal Clamp Vertical Clamp F Neck

    Crimp technology Maximum mechanical strength without

    damaging the fibre glass rod

    Patented crimp

    Direct bonding to end fitting• Ideal moisture barrier, avoids moisture ingress to the

    fibre glass rod

    EVA housing• High tracking and erosion resistance

    • Excellent performance under polluted conditions

    • Reduced maintenance costs

    Composite design• Lightweight – easy installation

    • Vandal and break resistant

    • Impact resistant

  • Hollow Core Insulators

    Raychem's Hollow Core Insulators consist of a glass fiber-reinforced epoxy tube,

    aluminum-casted flanges and silicone rubber housing.

    Application: Bushings for Transformers, Walls and Dead Tank Breakers

    Grading capacitors, chamber and support insulators for life tank breaker

    Current and Voltage Transformers in oil and SF6

    Cable Terminations

    Surge Arresters

    Features Benefits Low weight Easy handling during installation on site and in the factory, simple support structures, low transportation cost

    Composite structure Provides explosion safety for personnel and equipment in case of internal fault ( power arc & overpressure) & high safety in seismic areas

    Silicone housing Improves insulating behaviour at simultaneous stress of both, moisture and pollution . High UV resisitance. No maintenance - no cleaning or

    greasing - due to the hydrophobicity transfer.

    Flexible sheds Reduces risk of breakage during transport and assembly makes equipment vandalism proof

    Application in a Distribution System

    Polymeric Insulators for

    Air Break Switches

    Standoff Insulator

  • DISCLAIMER : The information contained in this Brochure is for general information purposes only. The information is provided by Raychem RPG Private Limited and whilst it endeavours to keep the information up-to-date and correct, it makes no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the its products or the information, products, services, or related graphics contained on the brochure for any purpose. Any reliance you place on such information is therefore strictly at your own risk.In no event will Raychem RPG be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of or in connection with the use of this brochure.

    All materials contained on this brochure are copyright © Raychem RPG (P) Ltd. September 2014. This information is issued to provide outline information only. Use, application or reproduction for any purpose or formation of any order or contract is prohibited unless agreed to in writing as condition of sale by Raychem RPG Private Limited. Raychem RPG Private Limited reserves the right to alter any product or service.

    Bengaluru:Namdev Garnet, No.37/7,

    Ground Floor, Aga Abbas Ali Road,

    Near Manipal Centre,

    Bengaluru - 560042

    Tel: +91 80 40676666

    Fax: +91 80 25586039

    Delhi:1107-1112, Vishwadeep Building,

    District Centre, Janakpuri,

    New Delhi - 110058

    Tel: +91 11 45753700

    Fax: +91 11 25557864

    Kolkata:1st Floor, Omega Building,

    Bengal Intelligent Park,

    Block EP & GP, Plot No.A2,

    M2 & N2, Salt Lake - Sector V,

    Electronics Complex,

    Kolkata - 700091

    Tel: +91 33

    40044081/82/83

    Fax: +91 33 40044084

    Regional Offices:

    Corporate Office:Raychem RPG (P) Ltd.,

    RPG House,

    463, Dr. Annie Besant Road,

    Worli, Mumbai-400030

    Tel: +91 22 24937485/6

    Fax: +91 22 24938879

    To learn more about

    Raychem RPG solutions & offerings

    visit : www.raychemrpg.com or e-mail your queries to :

    [email protected] Care Centre

    Tollfree No: 1800 209 9769

    ENERGY PRODUCTS DIVISION

    Mumbai: 6th Floor, Amfotech IT Park, Road No. 8, Opp. Old passport Office, Wagle Industrial Estate,Thane (W) Mumbai - 400604 Tel : +91 22 39916300

    Chennai:6th Floor, Sudarsan Building, 27, Whites Road, Royapet Chennai - 600 014 Tel: +91 44 65718437/38/39/40/41 Fax: +91 44 2851 4399