3
BACT/ALERT ® 3D Fast and accurate blood culture results

2019 BACT ALERT 3D 9317959 002 GB F€¦ · Blood Culture testing needs. Its high level of modularity smoothly fits into every lab setting, matching your way of working. Teamed with

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2019 BACT ALERT 3D 9317959 002 GB F€¦ · Blood Culture testing needs. Its high level of modularity smoothly fits into every lab setting, matching your way of working. Teamed with

BACT/ALERT® 3DFast and accurate blood culture results

Page 2: 2019 BACT ALERT 3D 9317959 002 GB F€¦ · Blood Culture testing needs. Its high level of modularity smoothly fits into every lab setting, matching your way of working. Teamed with

The same high-performance technology ensures safety and time-savingsPatented threshold detection technology eliminates a source of potential false negative.

Colorimetric change allows for earlier detection and immediate action 1.

Continuous monitoring gives immediate notification of results with instant visual and audible alerts and through MYLA® a remote alarm capability. User-directed bottle loading greatly facilitates the workflow.

BACT/ALERT® 3D

The same Touch-Wand-Load procedure simplifies your daily workloadThe BACT/ALERT® 3D expandable design enables you to add additional testing capacity as you need it. Its stackable modules can be arranged to save space and accommodate any laboratory layout.

BACT/ALERT® 3D meets your volume requirements - simply choose the number of modules required based on your laboratory testing volume.

84,000

70,000

56,000

44,000

35,000

28,000

21,000

14,000

7,000

ANNUAL BOTTLE VOLUME *

MODULE

CONTROLLER MODULE INCUBATION MODULE COMBINATION MODULE

This module enables up to 6 incubation modules to be operated from one set of electronics and integrated computer hardware.

Four incubation drawers of 60 cells giving a total capacity of 240 cells. Each drawer has an independent shaking mechanism, enabling static or shaken cultures within the same system.

Combine all the BACT/ALERT® 3D capabilities in a surprisingly compact format: a control and incubation module in a single instrument. Each module has a total incubation capacity of 120 cells (2 drawers) but can also connect to up to 3 incubation modules.

WEIGHT • 41 Kg (91 lbs)UNLOADED WEIGHT • 119 Kg (262 lbs)LOADED WEIGHT • 139 Kg (295 lbs)

UNLOADED WEIGHT • 90.7 Kg (200 lbs)LOADED WEIGHT • 95 Kg (210 lbs)

SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS

CAPACITY• 240 cells (60 cells/drawer)

CAPACITY• 120 cells (60 cells/drawer)

ELECTRICAL POWER SERVICES REQUIREMENTS• 100/120 Volts (50-60 HZ)• 220/240 Volts (50-60 HZ)

ELECTRICAL POWER SERVICES REQUIREMENTS• 100/120 Volts (50-60 HZ)• 220/240 Volts (50-60 HZ)

ELECTRICAL POWER SERVICES REQUIREMENTS• 100/120 Volts (50-60 HZ)• 220/240 Volts (50-60 HZ)

POWER CONSUMED IN WATTS• @115 V.A.C. 72 Watts typical• @230 V.A.C. 72 Watts typical

POWER CONSUMED IN WATTS• @115 V.A.C. 256 Watts (idle), 640 Watts typical• @230 V.A.C. 265 Watts (idle), 640 Watts typical

POWER CONSUMED IN WATTS• @115 V.A.C. 256 Watts (idle), 640 Watts typical• @230 V.A.C. 265 Watts (idle), 640 Watts typical

HEAT DISSIPATED• 245 Btu/Hr. 2840 maximum

HEAT DISSIPATED• 904 Btu/Hr. 2840 maximum

HEAT DISSIPATED• 904 Btu/Hr. 2840 maximum

SOUND EMISSION• 46.4 dB

SOUND EMISSION• 54.7 dB

SOUND EMISSION• 55.5 dB

ELECTRICAL POWER SERVICES REQUIREMENTS• Operating Temperature Range 10°C to 30°C (50°F-86°F)• Operating Humidity Range 10% to 90% relative humidity, non-condensing

ELECTRICAL POWER SERVICES REQUIREMENTS• Operating Temperature Range 10°C to 30°C (50°F-86°F)• Operating Humidity Range 10% to 90% relative humidity, non-condensing

ELECTRICAL POWER SERVICES REQUIREMENTS• Operating Temperature Range 10°C to 30°C (50°F-86°F)• Operating Humidity Range 10% to 90% relative humidity, non-condensing

35.6 CM (14 INCHES)

49.6 CM(19.5 INCHES)

49.6 CM (19.5 INCHES)

61.7 CM (24.3 INCHES)

61.7 CM(24.3 INCHES)

62.2 CM(24.5 INCHES)

91.4 CM (36 INCHES)

91.4 CM (36 INCHES)

78.1 CM (30.8 INCHES)

BACT/ALERT® 3D, the automated microbial detection system, adaptable to your routine Blood Culture testing needs. Its high level of modularity smoothly fits into every lab setting, matching your way of working.Teamed with BACT/ALERT® FAN® PLUS MEDIA you only have 2 bottle types to manage* for both blood and sterile body fluids. They detect a wide range of bacteria and yeast.All BACT/ALERT® 3D systems share the same time-proven technology, making them the most reliable partner for your laboratory.

* 2 bottles for adult patients for optimal recovery of potential pathogens; a third bottle type is available for pediatric patients and is only intended for detection from blood.

Page 3: 2019 BACT ALERT 3D 9317959 002 GB F€¦ · Blood Culture testing needs. Its high level of modularity smoothly fits into every lab setting, matching your way of working. Teamed with

Manufactured by bioMérieux Inc. • 100 Rodolphe Street • Durham, NC 27712 • USA

bioMérieux S.A. • 69280 Marcy l’Étoile • France • Tel.: + 33 (0)4 78 87 20 00 • Fax: +33 (0)4 78 87 20 90 www.biomerieux.com • www.biomerieux-diagnostics.com

LAB INFORMATICS SOLUTIONS

TRAINING & EDUCATION

1 - Shan L.H., Sakiman Z., Jairaman J. «Evaluation Study on Antimicrobial Neutralization with Automated Blood Culture Systems at Laboratory, Sunway Medical Centre», MEDLAB Asia Pacific 2016

*ID/AST : identification and susceptibility testing

FAN® PLUS MEDIA

10-1

9 /

9317

959

002/

GB/

F /

This

doc

umen

t is

not l

egal

ly b

indi

ng. b

ioM

érie

ux re

serv

es th

e rig

ht to

mod

ify s

peci

ficat

ions

with

out n

otic

e /

BIO

MÉR

IEUX

, the

BIO

MÉR

IEUX

logo

, BAC

T/AL

ERT,

FAN

and

MYL

A ar

e us

ed, p

endi

ng a

nd/o

r reg

iste

red

trad

emar

ks b

elon

ging

to b

ioM

érie

ux,

or o

ne o

f its

sub

sidi

arie

s, o

r one

if it

s co

mpa

nies

./ b

ioM

érie

ux S

A RC

S Ly

on 6

73 6

20 3

99 /

Pho

tos:

Mik

e M

artin

Med

ia, N

. Bou

chut

, A. G

uille

mau

d /

Prin

ted

in F

ranc

e /

thér

a /

RCS

Lyon

B 3

98 16

0 24

2

Innovation in microbiology must never stop – because your laboratory challenges never stop. For more than 50 years, bioMérieux has shared your commitment to continually strengthen laboratory impact on patient therapy.

BACT/ALERT® 3D is part of our integrated blood culture offer.Together with our ID/AST* offer, they meet your needs from the most routine to the truly challenging. Our offers let you leverage your expertise to deliver test results that impact timely, appropriate therapy.

Contact your local bioMérieux representative to find out more