Geotechnical Engineering Report
Platte Avenue over Sand Creek Pavements
Colorado Springs, Colorado
Yeh Project No.: 217-021
March 20, 2019
Prepared for:
HDR, Inc. Attn: Tammy C. Heffron, PE, ENV SP
1670 Broadway, #3400 Denver, Colorado 80202
Prepared by:
Yeh and Associates, Inc.
627 Elkton Dr. Colorado Springs, CO 80907
Phone: 719-434-1643
Geotechnical Engineering Report
Platte Avenue over Sand Creek Pavements
Colorado Springs, Colorado
Yeh Project No.: 217-021
March 20, 2019
Prepared by: Reviewed by: JG T. McCall, EIT Hai Ming Lim, P.E. Project Engineer Project Manager
Independent Reviewer: Robert L. LaForce, P.E. Senior Project Manager
3-20-19
i
Table of Contents
1 PURPOSE AND SCOPE OF STUDY.................................................................... 1
2 PROPOSED CONSTRUCTION ............................................................................ 1
3 GEOLOGICAL SETTING ...................................................................................... 2
4 FIELD EXPLORATION ......................................................................................... 2
4.1 Subsurface Exploration ...................................................................................... 2
4.2 Groundwater ...................................................................................................... 3
5 LABORATORY TESTING ..................................................................................... 3
6 SUBSURFACE AND SITE CONDITIONS ............................................................ 4
7 CONSTRUCTION CONSIDERATIONS ................................................................ 5
7.1 Site and Subgrade Preparation .......................................................................... 5
7.2 Fill Materials ....................................................................................................... 6
7.3 Site Grading ....................................................................................................... 6
7.4 Full Depth Reclamation (FDR) ........................................................................... 7
8 PAVEMENT DESIGN ............................................................................................ 7
8.1 Subgrade Strength ............................................................................................. 8
8.2 Traffic Loading ................................................................................................... 8
8.3 Pavement Thickness Design .............................................................................. 9
8.4 Pavement Materials ......................................................................................... 11
9 OTHER DESIGN CONSIDERATIONS ................................................................ 11
9.1 Chemical Test Results ..................................................................................... 11
10 LIMITATIONS ..................................................................................................... 12
11 REFERENCES .................................................................................................... 13
List of Tables
Table 6-1. Platte Ave. Existing Pavement Thickness ................................................................ 4
Table 6-2. Space Center Dr. Existing Pavement Thickness ...................................................... 4
Table 8-1. Design Subgrade Strength ........................................................................................ 8
Table 8-2. Traffic Volumes and Design ESAL ............................................................................ 9
Table 8-3. Pavement Design Parameters ................................................................................... 9
Table 8-4. Flexible Pavement Design Strength Coefficients ......................................................10
Table 8-5. Rigid Pavement Design Strength Coefficients ..........................................................10
ii
Table 8-6. Flexible Pavement Structural Number and Minimum Rigid Pavement Thickness .....10
Table 8-7. Recommended Minimum Flexible Pavement Thickness ...........................................11
Table 8-8. Recommended Minimum Mill and Overlay Thickness for Composite Pavement ......11
Table 8-9. Asphalt Mix Design Recommendations ....................................................................11
Table 9-1. Chemical Test Results ............................................................................................12
List of Appendices
Appendix A, Figure A-1 Boring Location Plan and Existing Conditions
Figure A-2 Pavement Repair Summary
Appendix B, Legend, Boring Logs, and Pavement Core Photos
Appendix C, Laboratory Test Results
Appendix D, Pavement Design Output Files and Traffic Data Memorandum
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
1
1 PURPOSE AND SCOPE OF STUDY
This report presents the results of Yeh and Associates, Inc.’s (Yeh) geotechnical engineering
study and pavement thickness recommendations for the proposed Platte Avenue pavement
rehabilitation associated with the bridge over Sand Creek replacement Project in Colorado
Springs, Colorado. The project location is shown in Figure1 presented before Appendix A. The
purpose of this study is to explore and evaluate the existing pavement and subsurface
conditions at the site, and present engineering recommendations for use by HDR, Inc. and the
City of Colorado Springs in the design and construction of the pavement sections. Subsurface
exploration and engineering recommendations for the bridge foundations and retaining walls are
presented in a separate report (Dated March 20, 2019, YA Project No. 217-021).
Our scope of services included the following:
• Advancing 11 borings along the roadway alignments to obtain existing pavement
thickness and subgrade information. Borings P-1 to P-8 were advanced along East
Platte Avenue and P-9 to P-11 were advanced along Space Center Drive.
• Performing laboratory tests on representative soil samples collected during the
subsurface exploration to determine the engineering characteristics.
• Preparing a report that:
o Summarizes field and laboratory data
o Presents the results of geotechnical engineering analyses
o Provides recommendations for pavement thickness design
2 PROPOSED CONSTRUCTION
Our understanding of the proposed construction is based on our discussions with the project
team and review of the FOR plans dated December 13, 2018. As part of the Platte Ave. over
Sand Creek bridge replacement project, approximately 1,000 feet of E. Platte Ave. and 400 feet
of Space Center Dr. will be slightly re-aligned and the pavement will be removed and
reconstructed. The proposed new pavement will be Hot Mix Asphalt (HMA) pavement.
Depending on the final grade, the HMA may be constructed over an aggregate base course
(ABC), full depth reclaimed (FDR) subbase course, or existing Portland Cement Concrete
Pavement (PCCP). Traffic data used in our pavement thickness design was provided by HDR
and are presented in Appendix D.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
2
3 GEOLOGICAL SETTING
The project area is located within the Young Alluvium Two (Qay2) and Middle Alluvium
Formation (Qam), and underlain by Pierre Shale Formation (Kp). The geological map of this
area is shown in Figure 2 presented before Appendix A. The Young Alluvium Two Formation
consists of poorly sorted sand, silty sand, minor pebble gravel, and several thin beds and lenses
of dark grayish brown to very dark grayish brown sediment. The Qay2 blankets large areas on
broad valley floors. Estimated thickness for Qay2 is 10 to 20 feet. The Middle Alluvium
Formation primarily consist of poorly sorted sand and subordinate amounts of gravel. This unit
underlies a terrace that is only slightly higher than Qay2. The estimated thickness for Qam is 20
to 50 feet. The Pierre Shale Formation is gray to dark-gray shale that weathers to brown and
olive green clay, lesser amounts of yellowish gray, medium to coarse grained sandstone. The
thickness in the quadrangle is about 5,000 feet. The encountered subsurface conditions in
general agrees with the geological descriptions.
4 FIELD EXPLORATION
4.1 Subsurface Exploration
Our subsurface exploration consisted of advancing 11 borings, borings P-1 to P-8 were
advanced along East Platte Ave. and Borings P-9 to P-11 were advanced along Space Center
Drive. The approximate boring locations are shown on Figure A-1, Boring Location Plan and
Existing Conditions in Appendix A. Vine Laboratories, Inc. under subcontract to Yeh, advanced
the borings with an ATV-mounted, CME 550 drill rig equipped with an automatic hammer with
an estimated energy transfer ratio of 75 percent. The drilling was performed with 4-inch outside
diameter (O.D.), continuous flight, solid stem augers. Prior to drilling, the pavement was cored
by Yeh using a 4-inch O.D. core barrel. Due to the thickness of the existing pavement, the
underlying PCCP pavement core in Boring P-4 could not be recovered.
Modified California (MC) tube, standard penetration test (SPT) split spoon samples, and bulk
samples of the cuttings were obtained by Yeh during the site exploration. The MC sampler has
an outside diameter of 2.5 inches, an interior diameter of 2.0 inches, is 12 inches in length, and
uses 4-inch long brass liners to collect samples. The SPT split spoon sampler has an outside
diameter of 2.0 inches, an interior diameter of 1.375 inches, and is 18 inches in length. The
samplers were seated at the bottom of the test hole, then advanced by a 140 pound automatic
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
3
hammer falling a distance of 30 inches. The penetration resistance shown on the boring logs is
the total number of blows required to advance the sampler for the final two 6-inch intervals.
The subsurface conditions encountered in the borings were logged by a representative of Yeh.
The boring locations were located with and hand held GPS with 10-feet accuracy and site
features. The boring logs and legend to the logs are included in Appendix B. Photos of the
pavement cores are also presented in Appendix B.
4.2 Groundwater
Groundwater was not encountered within our borings at the time of our field exploration for the
pavement borings. Groundwater observations to document seasonal fluctuations is outside our
scope of services and was not completed. Groundwater conditions at the site may vary
considerably throughout the year and from year to year. Groundwater variations may be a
result of different seasons, following precipitation events, after site grading changes, changes in
local irrigation practices, and due to changes in surface and subsurface drainage characteristics
of the surrounding area.
5 LABORATORY TESTING
The samples collected during the subsurface exploration were transported to Yeh’s laboratory in
Colorado Springs, Colorado. They were examined and a program of laboratory testing was
developed to evaluate the engineering properties of the subsurface materials. Representative
soil samples were tested to evaluate their engineering properties, using the following tests:
• natural moisture content
• in-situ dry density
• grain size analysis
• Atterberg limits
• pH, resistivity, water soluble sulfates and chlorides
• Hveem stabilometer (R-value)
Results of the Atterberg limit tests and grain size analyses were used to classify the soils
according to AASHTO and the Unified Soil Classification System (USCS) standards. Atterberg
limits tests were performed in general accordance with ASTM D4318, and the grain size
analyses were performed in general accordance with ASTM D421. Dry density tests and
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
4
moisture content tests were performed in general accordance with ASTM D7263 and ASTM
D2216, respectively.
The test results are shown on the boring logs and are included in Appendix C. Following the
completion of the laboratory testing, the field descriptions were confirmed or modified as
necessary and boring logs were finalized.
6 SUBSURFACE AND SITE CONDITIONS
This section presents the subsurface and site conditions at the site based on our observations
and explorations. The subgrade soils consist of silty to clayey sand with varying amounts of
gravel and classify as A-1-b to A-2-4 soils in accordance with AASHTO classifications.
Laboratory tests indicate the sand soils have a fines content (passing the #200 sieve) ranging
from 10 percent to 34 percent. Atterberg limits tests indicate soils are generally non-plastic to
low plasticity with liquid limit of 23 to 28, and plastic index of 3 to 11.
The existing asphalt concrete (AC) pavement along Platte Ave. was 6.5 to 9.5 inches thick with
no base course observed. PCCP was encountered beneath the asphalt concrete in two borings
at the west and east end of the west bound lanes of Platte Ave. The AC pavement was
observed to be 5 to 6-inches think along space center drive with no base course. Table 6-1 and
6-2 present a summary of the pavement thickness encountered.
Table 6-1. Platte Ave. Existing Pavement Thickness
Boring AC Thickness
(in) PCCP
Thickness (in) Boring
AC Thickness (in)
PCCP Thickness (in)
WB Platte Ave. EB Platte Ave.
P-1 5.5 6.0 P-5 6.5
Not Encountered
P-2 9.5 Not Encountered
P-6 9.0
P-3 9.0 P-7 8.5
P-4 10 8.0 P-8 8.0
Table 6-2. Space Center Dr. Existing Pavement Thickness
Boring AC Thickness (in) PCCP Thickness (in)
P-9 6.0
Not Encountered P-10 5.0
P-11 5.0
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
5
Based on visual observation, the existing pavement appears to be in good condition with little to
no obvious signs of distress. However, we understand the roadway was overlaid in 2016 or
early 2017 and is about 1 to 2 years old. Based on review of aerial photography (Google Earth
1999-2017), prior to the previous overlay, the pavement showed distress including moderate to
severe transverse and longitudinal cracks, and reflective cracks from the underlying PCCP on
the Platte Ave. westbound lanes.
7 CONSTRUCTION CONSIDERATIONS
Earthwork and grading will be required to achieve the final proposed grade of the roadways, we
anticipate maximum cut and fill thicknesses to be 3 feet. All excavations and embankment
grading should be performed in accordance with the Section 200 of the City of Colorado
Springs, City Engineering Division, Standard Specifications (2005) (COS Standards), or Section
203 of Colorado DOT Standard Specifications for Road and Bridge Construction (2017) (CDOT
2017) where it is not covered by the COS Standards.
7.1 Site and Subgrade Preparation
Initial site preparation for areas to receive new pavement sections should begin by stripping all
organic and other deleterious materials, and removing existing structures. The exposed
subgrade should be free of all organics, topsoil, debris, and loose or soft material. Deleterious
materials should be removed from the site or stockpiled for future use in proposed landscaped
or non-structural areas.
Following initial site preparation exposed pavement subgrade should be scarified to a minimum
depth of 6 inches, moisture conditioned, and re-compacted in accordance with Section 205 of
the COS Standards. Based upon the subsurface conditions encountered, subgrade soils
exposed during construction are anticipated to be relatively stable. However, the stability of the
subgrade may be affected by drainage and precipitation. If unstable conditions are encountered
or develop during construction, stability may be improved by processing the subgrade soils or
with other ground improvement techniques.
Following subgrade preparation and prior to placement of structural fill or pavement sections,
visual inspection and proof rolling at the subgrade is required to identify potential areas where
the subgrade contains soft / loose soils. The proof roll should be in accordance with Section
205 of the COS Standards. Areas which deform non-uniformly under heavy wheel loads should
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
6
either be moisture conditioned and re-compacted or excavated and replaced with structural fill.
The depth of over-excavation, if required, should be determined during construction. We
recommend that the proof rolling activities and visual inspection of the subgrade soils be
observed and evaluated by an experienced geotechnical engineer or engineer’s representative.
7.2 Fill Materials
Embankment fill should conform to Section 203 of the COS Standards and should be approved
by the City and the geotechnical engineer. On-site sandy soils are appropriate for use as
embankment fill. Import fill and onsite soils used as fill should be placed and compacted in
accordance with Section 205 of the COS Standards.
All fill materials should be placed in horizontal lifts that are 8-inches or less in loose thickness,
using equipment and procedures that will produce a uniform fill with the recommended moisture
contents and densities throughout the lift. The required percent of relative compaction and
moisture content for the embankment materials are presented in Section 205 of the COS
Standards.
7.3 Site Grading
All site excavation and embankment grading should conform to Section 200 of the COS
Standards.
Positive drainage should be provided during construction and maintained throughout the life of
the proposed structures. Design of drainage should include prevention of ponding of water on
or immediately adjacent to pavement areas. Surface features that could retain water in areas
adjacent to the structures should be sealed or eliminated.
We recommend that all permanent un-retained cut and fill slopes be constructed no steeper
than 2.5 H: 1 V. Cut slopes should be protected from surface water runoff to prevent erosion
and slope failure. Landscape sprinklers should be frequently checked for leaks and maintained
in good working order. Surface drainage should be provided around all permanent cuts and fills
to direct surface runoff away from the slope faces. Fill slopes, cut slopes, and other stripped
areas should be protected against erosion by re-vegetation or other methods. Concentrated
runoff should be prevented in areas susceptible to erosion or slope instability.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
7
7.4 Full Depth Reclamation (FDR)
Full depth reclamation (FDR) is a pavement rehabilitation method that the full thickness of the
existing pavement is uniformly pulverized and blended with the underlying base course and/or
subgrade to create a subbase material. The FDR materials are either used to increase the
strength of the subgrade, or used as a subbase layer within the pavement structure. Based on
the encountered pavement thickness and subgrade materials, the FDR should be planned to
extend a minimum of 12 inches below the existing pavement surface during the mixing process.
The FDR should be performed in accordance with CDOT Section 310 (Special Provision), Full
Depth Reclamation of Hot Mix Asphalt Pavement.
8 PAVEMENT DESIGN
Based on the proposed construction we understand that all pavement will be reconstructed for
20-year design period. The current approach is to FDR the existing asphalt concrete pavement
with the subgrade, and the FDR material will be spread over the new roadway width to provide
uniform subbase course within the pavement structure. HMA will placed on top of FDR, or
where grade adjustment is required, imported aggregate base course (ABC) may be placed
over FDR material. In the WB lanes of Platte Ave where PCCP underlies the AC, the AC will be
milled and overlaid with new HMA.
Based on the current design approach, a portion of the roadway west of the proposed new
bridge approach will be constructed on fill materials. To meet the design criteria, embankment
within 3 feet below the bottom of the pavement (bottom of AC or FDR materials) should consist
of fill materials with minimum R-value of 50. Typical CDOT Class 1 structure backfill granular
materials should meet the minimum R-value requirements.
The extent of the pavement where AC overlaying PCCP is not known. We have evaluated the
extent of this type of pavement based on the aerial photos prior to the overlay (2015 aerial
photo). Based on the aerial photo, we estimated the extent of the PCCP as shown in Figure A-2
presented in Appendix A. Note that the limits of PCCP presented in this report are for
informational purposes only and should be confirmed during construction.
The following sections present our pavement design recommendations for the above
alternatives. Pavement design was completed in accordance with Section II of COS Engineering
Criteria Manual: Pavement Design Criteria Manual, current CDOT manual, and in general
accordance with 1993 AASHTO Design Guide.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
8
8.1 Subgrade Strength
Based on our explorations and results of laboratory testing the pavement subgrade soils are
anticipated to consist primarily of sand with silt to silty sand, A-1-b to A-2-4. Subgrade soils are
relatively consistent along Platte Ave. and Space Center Drive, therefore one design subgrade
is used for our design. Based on R-value tests of 50 and 52 for combined bulk samples we have
assigned a design R-value of 51 to the existing subgrade soils. Design Resilient Modulus (Mr)
was calculated based on R-value on conversion guidelines presented in Section 4.2 of City of
Colorado Springs Pavement Design Manual. Effective modulus of subgrade reaction (k-value)
was calculated following Section 4.4 of COS Pavement Design Manual and a Loss of Support
value of 2.0. Table 8-1 presents the design subgrade strength parameters.
Table 8-1. Design Subgrade Strength
Parameter Design Value
Subgrade R-value 51
Subgrade Resilient Modulus (Mr), (psi)
13,500
Modulus of Subgrade Reaction (k-value), (pci) 695
Loss of Support (LS) 2.0
Effective Modulus of Subgrade Reaction (k-value), (pci)
60
8.2 Traffic Loading
Design traffic loads were calculated based on the data provided by HDR in the Technical
Memorandum dated June 27, 2018. This information was used to calculate the Average Annual
Daily Traffic (AADT) in 2019, growth rate, and determining the 18-kip Equivalent Single Axle
Loads (ESAL) loading for a 20-year design period. The truck factors and vehicle classifications
used in our 20-year ESAL calculation were selected in accordance with CDOT 2013 Pavement
Design Manual. The calculated 20-year ESAL was compared to COS default values present in
Table 4 of the COS Pavement Design Criteria Manual and the higher 20-year ESAL was used
for design.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
9
Table 8-2. Traffic Volumes and Design ESAL
Design Parameter Platte Avenue Space Center Drive
Roadway Functional Classification
Major Arterial Major/ Minor Collector
2019 AADT2 41,280 N/A
Trucks Percent of AADT2 CDOT Class 4-7: 10.02 CDOT Class 7-13: 3.09
N/A
Estimated Growth Rate2 1.6 N/A
Design Period (years) 20 20
Total Calculated ESAL over Design Period 3
9,688,128- Flexible 13,044,668- Rigid
N/A
COS Default ESAL over Design Period 1,3
4,500,000- Flexible 6,250,000- Rigid
200,000- Flexible 200,000- Rigid
1. Based on Table 4 COS Pavement Design Criteria Manual 2. Based on Vehicle Classification Report provided by HDR Technical Memorandum dated
June 27, 2018 3. Flexible- Hot mix asphalt pavement; Rigid- Portland cement concrete pavement N/A: Not available
8.3 Pavement Thickness Design
Pavement design was performed using the AASHTOWare program DARWin, Version 3.1, and
following the 1993 AASHTO Pavement Design Guide and City of Colorado Springs Pavement
Design Manual. The outputs from the pavement design are attached to this report in Appendix
D. Tables 8-3 to 8-5 present a summary of the design parameters used for design.
Table 8-3. Pavement Design Parameters
Parameter Platte Ave. (Flexible)
Platte Ave. (Rigid)
Space Center Dr.
Design Period (yrs.) 20 20 20
18-kip ESAL over design period 9,688,128 13,044,668 200,000
Reliability (%) 95 95 90
Overall Standard Deviation 0.44 0.34 0.44
Initial Serviceability Index 4.5 4.5 4.5
Terminal Serviceability Index 2.5 2.5 2.0
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
10
Table 8-4. Flexible Pavement Design Strength Coefficients
Parameter Value
Hot Mix Asphalt (HMA) 0.44
Drainage 1.0
FDR Subbase Course1 0.12
Aggregate Base Course (ABC) 2 0.12
Subgrade Soil Resilient Modulus (psi) 13,500
1. Based on laboratory produced FDR materials tested 2. ABC meeting COS Engineering Standard Specifications Manual
Table 8-5. Rigid Pavement Design Strength Coefficients
Parameter Value
Concrete Elastic Modulus (EC), (psi) 3,500,000
Concrete Modulus of Rupture (S’C), (psi) 650
Load Transfer Coefficient (J) 3.6
Effective Modulus of Subgrade Reaction (k-value), (pci) 60
Based on the above design parameters and coefficients, we have calculated a minimum
required structural number (flexible pavement) and minimum rigid pavement thickness for each
section as presented in Table 8-6. The recommended minimum pavement thickness are
presented in Tables 8-7. In the area where composite pavement comprised of asphalt concrete
overlaying PCCP was encountered (Platte Ave. westbound, east and west end), it is our
understanding mill and overlay with asphalt concrete pavement is preferred. The recommended
mill and overlay thickness at the composite pavement is presented in Table 8-8.
Table 8-6. Flexible Pavement Structural Number and Minimum Rigid Pavement Thickness
Roadway/Segment Calculated Minimum
Structural Number/ Rigid Pavement Thickness (in)1
Platte Ave – Flexible Pavement 4.07
Space Center Drive – Flexible Pavement 2.07
Platte Ave – Rigid Pavement 11.32
1. Based on 20-year design period
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
11
Table 8-7. Recommended Minimum Flexible Pavement Thickness
Location Alternative 1 Alternative 2
Platte Ave. 6” HMA 12” FDR
8” HMA 5” FDR
Space Center Dr. 4” HMA 6” FDR
HMA: Hot Mix Asphalt FDR: Full Depth Reclamation materials
Table 8-8. Recommended Minimum Mill and Overlay Thickness for Composite Pavement
East End of Platte Ave West End of Platte Ave
AC Mill Depth (in) 3 5.5
New HMA Thickness (in) 3 10.5
8.4 Pavement Materials
Hot mixed asphalt should meet the Pikes Peak Region Asphalt Paving Specifications. The
asphalt mix to be used for each pavement sections are presented in Table 8-9.
Table 8-9. Asphalt Mix Design Recommendations
Pavement Sections 20 Year
18K ESAL SuperPave
NDES Graded Binder
Aggregate Grading
Platte Ave.
Surface Course (2”) 9.7 million 100
PG 64-28 SX
Lower lifts (below surface course)
PG 64-28 S
Space Center
Dr.
Surface Course (2”) 200,000 100
PG 64-28 SX
Lower lifts (below surface course)
PG 64-28 S
9 OTHER DESIGN CONSIDERATIONS
9.1 Chemical Test Results
Yeh performed chemical tests on samples obtained during the field exploration that are
considered representative of soils encounter in the borings. The test results can be found in
Appendix C. The test results are summarized in Table 9-1.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
12
Table 9-1. Chemical Test Results
Samples Water Soluble Sulfates
Water Soluble Chlorides
pH Resistivity
YA-P-6 @ 10ft
<0.001% 0.0149% 7.1 2206 ohm.cm
YA-P-10 @ 2ft
<0.001% 0.0116% 7.8 3705 ohm.cm
These values should be used to select proper concrete type for the project in accordance with
Section 500 of COS Standards. A qualified corrosion engineer should review the laboratory
data and boring logs to determine the appropriate level of corrosion protection for materials in
contact with these soils.
10 LIMITATIONS
This report was prepared for the exclusive use of HDR, Inc. and the City of Colorado Springs.
Within the limitations of the scope, schedule, and budget, the work presented in this report was
performed in accordance with generally accepted principles and practices in this area at the
time this report was prepared. We make no other warranty, either express or implied.
The classifications, conclusions, and recommendations submitted in this report are based on
the data obtained from published and unpublished maps, reports, and geotechnical analyses.
Our conclusions and recommendations are based on our understanding of the project as
described in this report and the site conditions as interpreted from the explorations. This data
may not necessarily reflect variations in the subsurface conditions and water levels occurring at
other locations.
The nature and extent of subsurface variations may not become evident until excavation is
performed. Variations in the data may also occur with the passage of time. If during
construction, fill, soil, rock, or groundwater conditions appear to be different from those
described in this report, this office should be advised immediately so we could review these
conditions and reconsider our recommendations. If there is a substantial lapse of time between
the submission of this report and the start of work at the site, or if conditions have changed
because of natural forces or construction operations at or adjacent to the site, we recommend
that this report be reviewed to determine the applicability of the conclusions and
recommendations concerning the changed conditions or time lapse. We recommend on-site
observation of foundation excavations and foundation subgrade conditions by an experienced
geotechnical engineer or engineer’s representative.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
13
The scope of work of this investigation did not include hazardous materials sampling or
environmental sampling, investigation, or analyses. In addition, we did not evaluate the site for
potential impacts to natural resources, including wetlands, endangered species, or
environmentally critical areas.
11 REFERENCES
AASHTO, 2017. AASHTO Load Resistance Factor Design (LRFD) Bridge Design Specifications, Seventh Edition. Washington, DC: American Association of State Highway and Transportation Officials. 2017.
City of Colorado Springs, Engineering Criteria Manual, Pavement Design Criteria Manual
City of Colorado Springs, Standard Specification Manual, March, 2005.
Colorado Department of Transportation, 2013. 2013 Pavement Design Manual. Colorado Department of Transportation, 2017. CDOT Standard Specifications for Road and
Bridge Construction. 2017 Edition. Colorado Department of Transportation, M & S Standards, Denver, Colorado, July 2012 CGS, Madole, R.F. and Thorson, J.P., 2003. Geologic Map of the Elsmere 7.5 Minute
Quadrangle, El Paso County, Colorado.
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
14
Figure 1. Site Vicinity Map
(Google Earth)
Platte Avenue
Po
wers
Blv
d.
Project Site
Geotechnical Engineering Report YA Project No. 217-021 Platte Avenue over Sand Creek Pavements March 20, 2019
15
Figure 2. CGS Geologic Map of Project Area, (Madole, R.F. and Thorson, J.P., 2003)
Project Site
Appendix A
Figure A-1 Boring Location Plan and Existing Conditions
Figure A-2 Pavement Repair Summary
6170
6170
6170
617
0
6170
617
5
6175
6175
617
5
6175
6175
6175
6175
617
5
6175
6175
6175
6175
6175
617
5
6180
6180
6180
618
0
6180
6180
6180
618
0
618
0
6180
6180
6180
6180
6180
618
0
6180
6180
6180
6180
6180
6180
6180
6180
6180
6180
6180
6180
6180
SA
TT
6185
6185
618
5
6185
6185
618
5
618
5
6185
6185
618
5
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
6185
618
5
618
5
6185
6185
6185
SA
SA
ST
ST
SA
T
T
T
TT
TT
ST
SA
6190
6190
6190
6190
6190
6190
6190
61906190
6190
6190
61906190
6190619
0
6190 6190 6190
6190
6190
6190
6190
6190
6190
6190
6190
619
0
6190
6190
619
0
6190
6190
619
0
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
6190
619
0
6190
6190
6190
6190
6190
61906190
6190
6190
6190
6190
6190
6190
6190
6190
61906190
6190
6190
6190
6190
6190
6190
6190
6190
61906190
61906190
6190
6190
6190
6190
6190
6190
6190
6190
619
0
ST
TT
ST
TT
ST
SA
6195
6195
6195
619
5
619
5
6195
619
5
6195
6195
619
5
6195
6195
6195
6195
6195
6195
6195
6195
6195
619
5
6200
SA
TT
SA
SA
ST
ST
SA
T
T
T
TT
TT
ST
SA
ST
TT
ST
TT
ST
SA
REMOVED
CSG-L.57-08.99 TO BE
EXISTING STRUCTURE
REMOVED
CSG-L.56-08.97 TO BE
EXISTING STRUCTURE
HCL E. PLATTE AVE
mwalz 2:4
2:5
1 P
M
pw:\\
pw
hdruscen01:H
DR_
US_
Central_
01\
Docu
ments\
City_
of_
CO_
Sprin
gs_
CO\
CO_
Sprin
gs_
Platte_
Ave_
Sand_
Crk\
6.0
_C
AD_
BI
M\
6.2
_W
ork_In_
Progress\
Geotech\
BX -Pave
ment Borin
g Pla
n
719-272-8800Phone:Print Date:
File Name:
Horiz. Scale:
Unit Information
Unit Information
Index of Revisions
No. Description Date
Colorado Springs, CO 80919
5555 Tech Center Drive, Suite 310Computer File Information
Structure:
Sheet Subset:
Subset Sheets:
Designer:
Cadd:
Checker:
Date:
Date:
Date:
PROJECT:
STREET:
JOB NO.
DRAINAGE BASIN:
SHEET OF
SCALE: HORIZ. VERT.
BENCHMARK:
1:100
BX -Pavement Boring Plan
7/6/2018 719-385-5918Phone:
Colorado Springs, CO 80903
30 S Nevada
SCOPE OF REVIEW ACCORDINGLY.
DESIGN. THE CITY HAS LIMITED ITS
AS HAVING RESPONSIBILITY FOR THE
RECOGNIZES THE DESIGN ENGINEER
THE CITY OF COLORADO SPRINGS
STATEMENT:
105
+00
110
+00
115
+00
10+00
21+00
22+00
23+00
24+00
P-1
P-2
P-5
P-6
P-3
P-7
P-4
P-86.5"P-5
9.5"P-2
9.0"P-6
9.0"P-3
8.5"P-7
8.0"P-8
6.0"P-9
5.0"P-10
5.0"P-11
6"5.5"P-1
8"10"P-4
BRIDGE
110+00109+00108+00 111+00
22
+00
23
+00
10
+00
SA
ND
CR
EE
K
PLAN
SAND CREEK WATERSHED
TO COLORADO SPRINGS
TO POWERS BLVD
30'0' 15' 60'
Consulting Engineers & Scientists
Yeh and Associates, Inc.
107+00106+00 112+00 113+00 114+00
HML
MJW
7/6/2018
7/6/2018
PLATTE AVE PAVEMENT BORING LOCATION PLAN
PLATTE AVE AND SPACE CENTER DRIVE
A-1
PLATTE AVE OVER SAND CREEK PAVEMENT
#" Exisiting PCCP thickness (inches)
#" Existing AC thickness (inches)
P-# - Approximate Boring Location
SA
TT
SA
SA
ST
ST
SA
T
T
T
TT
TT
ST
SA
ST
TT
ST
TT
ST
SA
REMOVED
CSG-L.57-08.99 TO BE
EXISTING STRUCTURE
REMOVED
CSG-L.56-08.97 TO BE
EXISTING STRUCTURE
HCL E. PLATTE AVE
mwalz 2:0
9:4
2
PM
pw:\\
pw
hdruscen01:H
DR_
US_
Central_
01\
Docu
ments\
City_
of_
CO_
Sprin
gs_
CO\
CO_
Sprin
gs_
Platte_
Ave_
Sand_
Crk\
6.0
_C
AD
_BI
M\
6.2
_W
ork_In_
Progress\
Geotech\
BX -Pave
ment Repair Su
mm
ary
719-272-8800Phone:Print Date:
File Name:
Horiz. Scale:
Unit Information
Unit Information
Index of Revisions
No. Description Date
Colorado Springs, CO 80919
5555 Tech Center Drive, Suite 310Computer File Information
Structure:
Sheet Subset:
Subset Sheets:
Designer:
Cadd:
Checker:
Date:
Date:
Date:
PROJECT:
STREET:
JOB NO.
DRAINAGE BASIN:
SHEET OF
SCALE: HORIZ. VERT.
BENCHMARK:
1:100
BX -Pavement Repair Summary
7/6/2018 719-385-5918Phone:
Colorado Springs, CO 80903
30 S Nevada
SCOPE OF REVIEW ACCORDINGLY.
DESIGN. THE CITY HAS LIMITED ITS
AS HAVING RESPONSIBILITY FOR THE
RECOGNIZES THE DESIGN ENGINEER
THE CITY OF COLORADO SPRINGS
STATEMENT:
105
+00
110
+00
115
+00
21+00
22+00
23+00
24+00
BRIDGE
110+00109+00108+00 111+00
22
+00
23
+00
10
+00
SA
ND
CR
EE
K
PLAN
SAND CREEK WATERSHED
TO COLORADO SPRINGS
TO POWERS BLVD
HML
MJW
7/6/2018
7/6/2018
30'0' 15' 60'
Consulting Engineers & Scientists
Yeh and Associates, Inc.
107+00106+00 112+00 113+00 114+00
Approximate Limits of AC Mill and Overlay
Estimated Limits of PCCP Under AC.
PLATTE AVE AND SPACE CENTER DRIVE
PLATTE AVE OVER SAND CREEK PAVEMENT
PLATTE AVE PAVEMENT REPAIR SUMMARY
Platte Ave Approximate Limits of FDR
Space Center Drive Approximate Limits of FDR
A-2
Appendix B
Legend and Boring Logs Pavement Core Photos
Project Number: 217-021
Platte Ave over Sand Creek Pavement
Lithology Symbols(see Boring Logs for complete descriptions)
Asphalt Fill USCS Silty Sand
Lab Test Standards Other Lab Test AbbreviationspH Soil pH (AASHTO T289-91)S Water-Soluble Sulfate Content (AASHTO T290-91,
ASTM D4327)Chl Water-Soluble Chloride Content (AASHTO T291-91,
ASTM D4327)S/C Swell/Consolidation (ASTM D4546)UCCS Unconfined Compressive Strength (ASTM D2166)R-Value Resistance R-Value (ASTM D2844)DS (C) Direct Shear cohesion (ASTM D3080)DS (phi) Direct Shear friction angle (ASTM D3080)Re Electrical Resistivity (AASHTO T288-91)PtL Point Load Strength Index (ASTM D5731)
Notes
Moisture Content ASTM D2216Dry Density ASTM D7263Sand/Fines Content ASTM D421, ASTM C136,
ASTM D1140Atterberg Limits ASTM D4318AASHTO Class. AASHTO M145,
ASTM D3282USCS Class. ASTM D2487(Fines = % Passing #200 SieveSand = % Passing #4 Sieve, but not passing #200 Sieve)
Auger Cuttings
Modified CaliforniaSampler(2.5 inch OD, 2.0inch ID)
StandardPenetration Test(ASTM D1586)
Sample Types
Legend for Symbols Used on Borehole Logs
Project:Yeh and Associates, Inc.C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
1. "Penetration Resistance" on the Boring Logs refers to the uncorrected N value for SPT samples only, as per ASTMD1586. For samples obtained with a Modified California sampler, drive depth is 12 inches, and "PenetrationResistance" refers to the sum of all blows. Where blow counts were > 50 for the 3rd increment (SPT) or 2nd increment(MC), "Penetration Resistance" combines the last and 2nd-to-last blows and lengths; for other increments with > 50blows, the blows for the last increment are reported.2. The Modified California sampler used to obtain samples is a 2.5-inch OD, 2.0-inch ID (1.95-inch ID with liners),split-barrel sampler with internal liners, as per ASTM D3550. Sampler is driven with a 140-pound hammer, dropped 30inches per blow.3. "ER" for the hammer is the Reported Calibrated Energy Transfer Ratio for that specific hammer, as provided by thedrilling company.
118095.0
5-5-5
2-2-3
10
5
0.0 - 1.0 ft. 5.5" asphalt over 6" concretepavement.
1.0 - 6.5 ft. silty SAND, dark brown tobrown, moist.
Bottom of Hole at 6.5 ft.
Total Depth: 6.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-1
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
San
d C
onte
nt(%
)
Gra
vel C
onte
nt(%
)
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
217736.16-8-9
8-7-6
1-3
5-7
17
13
4
12
0.0 - 0.8 ft. 9.5" asphalt pavement.
0.8 - 11.0 ft. silty SAND FILL, with clayseams, dark brown to brown, moist.
Bottom of Hole at 11.0 ft.
Total Depth: 11.0 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-2
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
10
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
San
d C
onte
nt(%
)
Gra
vel C
onte
nt(%
)
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
2-3-2
2-1-1
1-1-1
1-1-1
5
2
2
2
0.0 - 0.8 ft. 9" asphalt pavement.
0.8 - 11.5 ft. silty SAND FILL, dark brown and brown,moist.
Bottom of Hole at 11.5 ft.
Total Depth: 11.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-3
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
10
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
4-4-3
7-7-8
7
15
0.0 - 1.5 ft. 10" asphalt over 8" concrete pavement.
1.5 - 6.5 ft. silty SAND, brown, moist, mediumdense.
Bottom of Hole at 6.5 ft.
Total Depth: 6.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-4
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
22 NPNV7539.6 121.612-15
12-13
4-5
5-6
27
25
9
11
0.0 - 0.6 ft. 6.5" asphalt pavement.
0.6 - 11.0 ft. silty SAND with trace ofgravels, dark brown to light brown, moist,medium dense to loose.
Bottom of Hole at 11.0 ft.
Total Depth: 11.0 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-5
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
10
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
San
d C
onte
nt(%
)
Gra
vel C
onte
nt(%
)
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
24 1128
pH=7.1S=0.001%Chl=0.0149%Re=2206ohm·cm
10.9 123.37-7
12-15-13
14
28
0.0 - 0.8 ft. 9" asphalt pavement.
0.8 - 6.5 ft. silty SAND FILL, dark brown to lightbrown, moist.
Bottom of Hole at 6.5 ft.
Total Depth: 6.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-6
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
28 3236939.3
9-10
6-15-12
19
27
0.0 - 0.7 ft. 8.5" asphalt pavement.
0.7 - 6.5 ft. silty SAND FILL, light brownto dark gray, moist.
Bottom of Hole at 6.5 ft.
Total Depth: 6.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-7
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
San
d C
onte
nt(%
)
Gra
vel C
onte
nt(%
)
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
34 5269.95-11-12
9-15
7-10-13
5-7-6
23
24
23
13
0.0 - 0.7 ft. 8" asphalt pavement.
0.7 - 11.5 ft. silty SAND, brown to light brown, moist,medium dense.
Bottom of Hole at 11.5 ft.
Total Depth: 11.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-8
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
10
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
177856.4
6-8-7
14-15-12
7-7-8
5-6-7
15
27
15
13
0.0 - 0.5 ft. 6" asphalt pavement.
0.5 - 11.5 ft. silty SAND, dark gray togray, moist, medium dense.
-brown below 7'.
Bottom of Hole at 11.5 ft.
Total Depth: 11.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-9
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
10
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
San
d C
onte
nt(%
)
Gra
vel C
onte
nt(%
)
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
pH=7.8S=0.001%Chl=0.0116%Re=3705ohm·cm3-1-3
5-5-5
4
10
0.0 - 0.4 ft. 5" asphalt pavement.
0.4 - 6.5 ft. silty SAND, brown, moist, mediumdense.
Bottom of Hole at 6.5 ft.
Total Depth: 6.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-10
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
82 NP10996.32-2-5
6-5-6
8-7-6
6-6-6
7
11
13
12
0.0 - 0.4 ft. 5" asphalt pavement.
0.4 - 11.5 ft. silty SAND, brown, moist,loose to medium dense.
Bottom of Hole at 11.5 ft.
Total Depth: 11.5 ft
Ground Elevation:
Coordinates: N: E:
Location:
Groundwater Levels:
Logged By: R. Desterhouse
Final By: HML
SymbolDepthDate
Weather Notes:
Inclination from Horiz.: Vertical
Boring Began: 5/8/2018
Boring Completed: 5/8/2018
Drilling Method(s): Solid-Stem Auger
Driller: Vine Laboratories
Drill Rig: CME 550
Hammer Type: Automatic (hydraulic)--
--
--
Night Work:
ProjectName:
PAGE1 of 1
AASHTO& USCSClassifi-cations
Fin
es C
onte
nt(%
)
Pla
stic
ityIn
dex
Project Number: 217-021C o n s u l t i n g E n g i n e e r s & S c i e n t i s t s
Liqu
idLi
mit
Field Notesand
Other LabTests
Platte Ave over Sand Creek Pavement
AtterbergLimits
Boring No.: P-11
Yeh and Associates, Inc.E
leva
tion
(fee
t)
Dep
th(f
eet)
5
10
Sam
ple
Typ
e/A
dvan
cem
ent M
etho
d
BO
RIN
G L
OG
201
5 2
17-0
21
PA
VE
ME
NT
GIN
T.G
PJ
201
5 Y
EH
AS
SO
CIA
TE
S T
EM
PLA
TE
.GD
T
2015
LIB
RA
RY
.GLB
6/1
9/1
8
San
d C
onte
nt(%
)
Gra
vel C
onte
nt(%
)
Moi
stur
eC
onte
nt (
%)
Dry
Den
sity
(pcf
)Blowsper6 in
Pen
etra
tion
Res
ista
nce
Lith
olo
gy
Soil Samples
Material Description
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
FIGURE
P-1
Pavement Core Photos
Boring: P-1
Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-2
FIGURE
P-2Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-3
FIGURE
P-3Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-4
FIGURE
P-4Platte Avenue over Sand Creek
Colorado Springs, Colorado
Note: Partial asphalt core over 10"
concrete core could not be retrieved from
this boring. Pavement was drilled through.
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-5
FIGURE
P-5Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-6
FIGURE
P-6Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-7
FIGURE
P-7Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-8
FIGURE
P-8Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-9
FIGURE
P-9Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-10
FIGURE
P-10Platte Avenue over Sand Creek
Colorado Springs, Colorado
PROJECT NO. 217-021
DRAWN: 5/16/2018
DRAWN BY: DG
CHECKED BY: HML
FILE NAME:
Pavement Core Photos
Boring: P-11
FIGURE
P-11Platte Avenue over Sand Creek
Colorado Springs, Colorado
Appendix C
Laboratory Test Results
Project No: Date: 6/18/2018
Gradation Atterberg
Chloride
%
P-1 5-6.5 SPT 5.0 - 9 80 11 - - - - - - - - A-1-b ( 0 ) SP-SM
P-3 2-3.5 SPT 6.1 - 3 77 21 - - - - - - - - A-2-4 ( 0 ) SM
P-5 2-3 MC 9.6 121.6 3 75 22 NV NP NP - - - - - A-2-4 ( 0 ) SM
P-6 2-3 MC 10.9 123.3 - - 24 28 17 11 - - - - - A-2-6 ( 0 ) SC
P-7 5-6.5 SPT 9.3 - 3 69 28 23 20 3 - - - - - A-2-4 ( 0 ) SM
P-8 2-3.5 SPT 9.9 - - - 34.2 26 21 5 - - - - - A-2-4 ( 0 ) SM
P-9 5-6.5 SPT 6.4 - 5 78 17 - - - - - - - - A-1-b ( 0 ) SM
P-11 2-3.5 SPT 6.3 - 9 82 10 - - - - - - - - A-1-b ( 0 ) SP-SM
P-1,2,3,5 0-5 BULK 9.1 - 3 67 30 25 17 8 - - - - 50 A-2-4 ( 0 ) SC
P-4,7,9,10,11 0-5 BULK 7.2 - 5 74 21 23 19 4 - - - - 52 A-1-b ( 0 ) SM-SC
25% AC Mix - - 2.4 - 16 67 17 NV NP NP - - - - 61 A-1-b ( 0 ) SM
PL PIAASHTO USCS
Resistivity
ohm.cm
R-
Value
CLASSIFICATIONWater
Soluble
Sulfate %
Sample
Type
Gravel
> #4
(%)
Sand
(%)
Fines <
#200
(%)
217-021 Project Name:
LL
YEH & ASSOCIATES, INC
Summary of Laboratory Test Results
Sample Location Natural
Moisture
Content
(%)
Natural
Dry
Density
(pcf)
PH
Platte Ave over Sand Creek Pavement
Boring No. Depth (ft)
Page 1 Summary 217-021
Drawn By: JTM
Date: 06/18/18
¾ "
½"
-
-
-
-
69
31
-
100
99
91
#200 11
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
Gravel (%)
Sand (%)
9
80
LL
PL
Platte Ave over Sand Creek
Bridge Pavement Project Name:
Sample ID: P-1
Sample
Depth (ft.):5'-6.5'
Sample
Description:A-1-b (0) / SP-SM
Project No.: 217-021
Figure No.: -
Fines (%) 11 PI -
Sieve
Size
%
Passing
Checked By: HML
-
-
-
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
¾ "
½"
-
-
-
-
88
62
-
-
100
97
#200 21
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
Gravel (%)
Sand (%)
3
76
LL
PL
Platte Ave over Sand Creek
Bridge Pavement Project Name:
Sample ID: P-3
Sample
Depth (ft.):2'-3.5'
Sample
Description:A-2-4 (0) / SM
Project No.: 217-021
Figure No.: -
Fines (%) 21 PI -
Sieve
Size
%
Passing
Checked By: HML
-
-
-
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
Sample
Description:A-2-4 (0) / SM
Project No.: 217-021
Figure No.: -
Fines (%) 22 PI NP
Platte Ave over Sand Creek
Bridge Pavement Project Name:
Sample ID: P-5
Sample
Depth (ft.):2'-3'
Gravel (%)
Sand (%)
3
75
LL
PL
¾ "
½"
NV
NP
100
100
86
59
100
100
100
97
#200 22
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
¾ "
½"
23
20
100
100
86
64
100
100
100
97
#200 28
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
Gravel (%)
Sand (%)
3
69
LL
PL
Platte Ave over Sand Creek
Pavement Project Name:
Sample ID: P-7
Sample
Depth (ft.):5 - 6.5
Sample
Description:A-2-4 (0) / SM
Project No.: 217-021
Figure No.: -
Fines (%) 28 PI 3
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
Sample
Description:A-1-b (0) / SM
Project No.: 217-021
Figure No.: -
Fines (%) 17 PI -
Platte Ave over Sand Creek
Pavement Project Name:
Sample ID: YA-P-9
Sample
Depth (ft.):5 - 6.5
Gravel (%)
Sand (%)
5
78
LL
PL
¾ "
½"
-
-
100
100
76
39
100
100
100
95
#200 17
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
Sample
Description:A-1-b (0) / SP-SM
Project No.: 217-021
Figure No.: -
Fines (%) 10 PI -
Platte Ave over Sand Creek
Pavement Project Name:
Sample ID: P-11
Sample
Depth (ft.):2 - 3.5
Gravel (%)
Sand (%)
9
81
LL
PL
¾ "
½"
-
-
100
100
69
29
100
100
99
91
#200 10
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
Sample
Description:A-2-4 (0) / SC
Project No.: 217-021
Figure No.: -
Fines (%) 30 PI 8
Platte Ave over Sand Creek
Pavement Project Name:
Sample ID: P-1,2,3,5
Sample
Depth (ft.):0-5
Gravel (%)
Sand (%)
3
67
LL
PL
¾ "
½"
25
17
100
100
85
59
100
100
100
97
#200 30
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
Sample
Description:A-1-b (0) / SM-SC
Project No.: 217-021
Figure No.: -
Fines (%) 21 PI 4
Platte Ave over Sand Creek
Pavement Project Name:
Sample ID: P-4,7,9,10,11
Sample
Depth (ft.):0-5
Gravel (%)
Sand (%)
5
74
LL
PL
¾ "
½"
23
19
100
100
77
42
100
100
98
95
#200 21
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Drawn By: JTM
Date: 06/18/18
Sieve
Size
%
Passing
Checked By: HML
100
100
100
3"
2 ½"
2"
⅜"
#4
#10
#40
1 ½"
1"
Sample
Description:A-1-b (0) / SM
Project No.: 217-021
Figure No.: -
Fines (%) 17 PI NP
Platte Ave over Sand Creek
Pavement Project Name:
Sample ID: 25% Asphalt Mix
Sample
Depth (ft.):-
Gravel (%)
Sand (%)
16
67
LL
PL
¾ "
½"
NV
NP
100
100
63
35
100
99
97
84
#200 17
Yeh & Associates, Inc. Geotechnical Engineering Consultants
SIEVE ANALYSIS
0
10
20
30
40
50
60
70
80
90
100
0.010.11101001000
Perc
en
t P
assin
g
Particle Size (mm)
20040103/8" 41/2"3/4"3"12" 6" 1" 30 508 16
Sieve Analysis Hydrometer Analysis
Sieve Opening in Inches U.S. Standard Sieves Size of Particles in mm
1002"
Revised 04/27/2004
Project Number: 217-021 Project Name: Platte Ave Over Sand CreekSample Id: Depth (ft): 0-5Location: Platte Ave Class: 0Date Sampled: 5/24/18 Date Tested: 6/6/18
R-Value at 300 psi exudation pressure = 50
Test Compact. Density Moist. Horizont. Sample Exud. R R
No. Press. (pcf) (%) Pressure Height Pressure Value Value(psi) (psi)'@ 160 psi (in). (psi) Correct.
1 300 121.2 7.0 48 2.61 640 57 622 300 119.2 8.0 59 2.61 416 49 543 300 122.8 9.0 68 2.55 226 43 48
Sampled by: Tested by: M.Aichiouene Checked by:B.LaForceRev.2-2/2011
P-1,2,3,5
Ming
YEH AND ASSOCIATES, INCR-Value Test Report
0
10
20
30
40
50
60
70
80
90
100
100200300400500600700800
R-V
alue
Exudation Pressure (psi)
YEH AND ASSOCIATES, INCR-Value Test Report
Project Number: 217-021 Project Name: Platte Ave Over Sand CreekSample Id: Depth (ft): 0-5Location: Platte Ave Class: 0Date Sampled: 5/24/18 Date Tested: 6/6/18
R-Value at 300 psi exudation pressure = 52
Test Compact. Density Moist. Horizont. Sample Exud. R R
No. Press. (pcf) (%) Pressure Height Pressure Value Value(psi) (psi)'@ 160 psi (in). (psi) Correct.
1 300 123.3 6.0 44 2.59 575 60 652 300 120.8 7.0 50 2.60 397 55 573 300 126.9 8.0 56 2.49 216 50 48
Sampled by: Tested by: M.Aichiouene Checked by:B.LaForceRev.2-2/2011
P-4,7,9,10,11
Ming
0
10
20
30
40
50
60
70
80
90
100
100200300400500600700800
R-V
alue
Exudation Pressure (psi)
YEH AND ASSOCIATES, INCR-Value Test Report
Project Number: 217-021 Project Name: Platte Ave Over Sand CreekSample Id: Depth (ft): 0-5Location: Platte Ave Class: 0Date Sampled: 5/24/18 Date Tested: 6/6/18
R-Value at 300 psi exudation pressure = 61
Test Compact. Density Moist. Horizont. Sample Exud. R R
No. Press. (pcf) (%) Pressure Height Pressure Value Value(psi) (psi)'@ 160 psi (in). (psi) Correct.
1 300 119.4 7.0 28 2.65 542 73 762 300 121.5 8.0 40 2.56 401 63 683 300 130.0 9.0 44 2.41 234 59 57
Sampled by: Tested by: M.Aichiouene Checked by:B.LaForceRev.2-2/2011
25% Asphalt Mix
Ming
0
10
20
30
40
50
60
70
80
90
100
100200300400500600700800
R-V
alue
Exudation Pressure (psi)
Appendix D
Pavement Design Output
Traffic Data Memorandum
Page 1
1993 AASHTO Pavement Design
DARWin Pavement Design and Analysis System
A Proprietary AASHTOWareComputer Software Product
Yeh & Associates, Inc.
Flexible Structural Design Module
Platte Ave.: New Asphalt Pavement with FDR
Flexible Structural Design
18-kip ESALs Over Initial Performance Period 9,688,128 Initial Serviceability 4.5 Terminal Serviceability 2.5 Reliability Level 95 %Overall Standard Deviation 0.44 Roadbed Soil Resilient Modulus 13,500 psiStage Construction 1
Calculated Design Structural Number 4.07 in
Rigorous ESAL Calculation
Performance Period (years) 20 Two-Way Traffic (ADT) 41,280 Number of Lanes in Design Direction 2 Percent of All Trucks in Design Lane 90 %Percent Trucks in Design Direction 50 %
VehicleClass
Percent
ofADT
Annual
%Growth
Average InitialTruck Factor
(ESALs/Truck)
Annual %Growth in
TruckFactor
Accumulated18-kip ESALs
over PerformancePeriod
3 86.89 1.6 0.003 0 413,0207 10.02 1.6 0.249 0 3,953,187
13 3.09 1.6 1.087 0 5,321,920Total 100 - - - 9,688,128
Growth Compound
Total Calculated Cumulative ESALs 9,688,128
Specified Layer Design
Layer
Material Description
StructCoef.(Ai)
DrainCoef.(Mi)
Thickness(Di)(in)
Width
(ft)
Calculated
SN (in)1 HMA 0.44 1 6 - 2.642 FDR Material or ABC 0.12 1 12 - 1.44
Total - - - 18.00 - 4.08
Page 1
1993 AASHTO Pavement Design
DARWin Pavement Design and Analysis System
A Proprietary AASHTOWareComputer Software Product
Yeh & Associates, Inc.
Flexible Structural Design Module
Platte Ave.: New Asphalt Pavement with Minimal Grade Change
Flexible Structural Design
18-kip ESALs Over Initial Performance Period 9,688,128 Initial Serviceability 4.5 Terminal Serviceability 2.5 Reliability Level 95 %Overall Standard Deviation 0.44 Roadbed Soil Resilient Modulus 13,500 psiStage Construction 1
Calculated Design Structural Number 4.07 in
Rigorous ESAL Calculation
Performance Period (years) 20 Two-Way Traffic (ADT) 41,280 Number of Lanes in Design Direction 2 Percent of All Trucks in Design Lane 90 %Percent Trucks in Design Direction 50 %
VehicleClass
Percent
ofADT
Annual
%Growth
Average InitialTruck Factor
(ESALs/Truck)
Annual %Growth in
TruckFactor
Accumulated18-kip ESALs
over PerformancePeriod
3 86.89 1.6 0.003 0 413,0207 10.02 1.6 0.249 0 3,953,187
13 3.09 1.6 1.087 0 5,321,920Total 100 - - - 9,688,128
Growth Compound
Total Calculated Cumulative ESALs 9,688,128
Specified Layer Design
Layer
Material Description
StructCoef.(Ai)
DrainCoef.(Mi)
Thickness(Di)(in)
Width
(ft)
Calculated
SN (in)1 HMA 0.44 1 8 - 3.522 FDR Material or ABC 0.12 1 5 - 0.60
Total - - - 13.00 - 4.12
Page 1
1993 AASHTO Pavement Design
DARWin Pavement Design and Analysis System
A Proprietary AASHTOWareComputer Software Product
Yeh & Associates, Inc.
Flexible Structural Design Module
Spcae Center Dr.: New Asphalt Pavement with FDR
Flexible Structural Design
18-kip ESALs Over Initial Performance Period 200,000 Initial Serviceability 4.5 Terminal Serviceability 2 Reliability Level 90 %Overall Standard Deviation 0.44 Roadbed Soil Resilient Modulus 13,500 psiStage Construction 1
Calculated Design Structural Number 2.07 in
Specified Layer Design
Layer
Material Description
StructCoef.(Ai)
DrainCoef.(Mi)
Thickness(Di)(in)
Width
(ft)
Calculated
SN (in)1 New HMA 0.44 1 4 - 1.762 FDR Material or ABC 0.12 1 8 - 0.96
Total - - - 12.00 - 2.72
Page 1
1993 AASHTO Pavement Design
DARWin Pavement Design and Analysis System
A Proprietary AASHTOWareComputer Software Product
Yeh & Associates, Inc.
Overlay Design Module
WB Platte Ave West Edge of Project Minimum Grade Change (remove all existing AC)
AC Overlay of AC/PCC Pavement
Pavement Thickness for Future Traffic 11.34 in
Design Method
Effective ExistingOverlay Thickness (in)
OverlayThickness (in)
Condition Survey 4.96 10.51
Pavement Thickness for Future Traffic
Future 18-kip ESALs Over Design Period 13,221,735 Initial Serviceability 4.5 Terminal Serviceability 2.5 PCC Modulus of Rupture 650 psiPCC Elastic Modulus 3,500,000 psiStatic k-value 60 psi/inReliability Level 95 %Overall Standard Deviation 0.34 Load Transfer Coefficient, J 3.6 Overall Drainage Coefficient, Cd 1.1
Calculated Thickness for Future Traffic 11.34 in
Effective Pavement Thickness - Condition Survey Method
Existing PCC Thickness 6 inExisting AC Thickness 5.5 inAC Milling Thickness 5.5 inRut Depth - inDurability Adjustment Factor 1 Fatigue Damage Adjustment Factor - AC Quality Adjustment Factor 0.9 Number of Deteriorated Joints - per miNumber of Deteriorated Cracks 0 per miNumber of Unrepaired Punchouts 0 per miNumber of Expansion Joints, - Exceptionally Wide Joints, or AC Full Depth Patches 70 per mi
Calculated Results
Calculated Joints and Cracks Adjustment Factor 0.83 Calculated Effective Pavement Thickness 4.96 in
Page 2
Future Rigorous ESAL Calculation
Performance Period (years) 20 Two-Way Traffic (ADT) 41,280 Number of Lanes in Design Direction 2 Percent of All Trucks in Design Lane 90 %Percent Trucks in Design Direction 50 %
VehicleClass
Percent
ofADT
Annual
%Growth
Average InitialTruck Factor
(ESALs/Truck)
Annual %Growth in
TruckFactor
Accumulated18-kip ESALs
over PerformancePeriod
3 86.89 1.6 0.003 0 413,0207 10.02 1.6 0.285 0 4,524,733
13 3.09 1.6 1.692 0 8,283,982Total 100 - - - 13,221,735
Growth Compound
Total Calculated Cumulative ESALs 13,221,735
Layer Information
Layer
Material Description
Thickness
(in)
One DirWidth
(ft)1 AC Overlay 10.5115704 -
Total - 10.51 -
Page 1
1993 AASHTO Pavement Design
DARWin Pavement Design and Analysis System
A Proprietary AASHTOWareComputer Software Product
Yeh & Associates, Inc.
Overlay Design Module
WB Platte Ave East Edge of Project
AC Overlay of AC/PCC Pavement
Pavement Thickness for Future Traffic 11.32 in
Design Method
Effective ExistingOverlay Thickness (in)
OverlayThickness (in)
Condition Survey 9.76 3.13
Pavement Thickness for Future Traffic
Future 18-kip ESALs Over Design Period 13,044,668 Initial Serviceability 4.5 Terminal Serviceability 2.5 PCC Modulus of Rupture 650 psiPCC Elastic Modulus 3,500,000 psiStatic k-value 60 psi/inReliability Level 95 %Overall Standard Deviation 0.34 Load Transfer Coefficient, J 3.6 Overall Drainage Coefficient, Cd 1.1
Calculated Thickness for Future Traffic 11.32 in
Effective Pavement Thickness - Condition Survey Method
Existing PCC Thickness 8 inExisting AC Thickness 10 inAC Milling Thickness 3 inRut Depth - inDurability Adjustment Factor 1 Fatigue Damage Adjustment Factor - AC Quality Adjustment Factor 0.9 Number of Deteriorated Joints - per miNumber of Deteriorated Cracks 0 per miNumber of Unrepaired Punchouts 0 per miNumber of Expansion Joints, - Exceptionally Wide Joints, or AC Full Depth Patches 70 per mi
Calculated Results
Calculated Joints and Cracks Adjustment Factor 0.83 Calculated Effective Pavement Thickness 9.76 in
Page 2
Future Rigorous ESAL Calculation
Performance Period (years) 20 Two-Way Traffic (ADT) 41,280 Number of Lanes in Design Direction 2 Percent of All Trucks in Design Lane 90 %Percent Trucks in Design Direction 50 %
VehicleClass
Percent
ofADT
Annual
%Growth
Average InitialTruck Factor
(ESALs/Truck)
Annual %Growth in
TruckFactor
Accumulated18-kip ESALs
over PerformancePeriod
3 86.89 1.6 0.003 0 407,4897 10.02 1.6 0.285 0 4,464,137
13 3.09 1.6 1.692 0 8,173,042Total 100 - - - 13,044,668
Growth Simple
Total Calculated Cumulative ESALs 13,044,668
Layer Information
Layer
Material Description
Thickness
(in)
One DirWidth
(ft)1 AC Overlay 3.1326183 -
Total - 3.13 -
Location: PLATTE AVE WIO SAND CREEK BRIDGE
Date Range: 81112017 - 81712017
Site Code: 01DATA SOLUTIONS
Tuesday Wednesday Thursday Friday Saturday Sunday Monday8/112017 812/2017 8/3/2017 8/4/2017 816/2017 81612017 8/712017 MId-Week Average
Time EB WB Total EB WB Total EB WB Total EB WB Total EB WB Total EB WB Total EB WB Total EB WB Total1200AM 105 66 171 105 66 1711:00AM 84 49 133 84 49 1332:00AM 68 42 110 68 42 1103:00AM 55 101 156 - - 55 101 156
4:00AM 125 184 309 125 184 3095:00AM 374 742 1,116 374 742 1,1166:00 AM 1330 1643 2,973
- 1,330 1,643 2,9737:00 AM 1,605 2292 3,897 - - - - - - 1,605 2,292 3,8978:00 AM 981 1,678 2,659 - 981 1678 2,6599:00 AM 820 1,339 2,159 - - - - - - - - - -- - - - - - 820 1339 2,15910:00AM 790 1,241 2,031 - - - - - - - - - 790 1,241 2,03111:00AM 864 1,192 2,056 - - - - - - - - - - - - - - - 864 1,192 2,05612:00 PM 1.073 1,176 2,249 - - - - - - - - - - - - - - 1,073 1,176 2,2491:00 PM 957 1,105 2,062 - - - - - - - - - - - - - - - - 957 1,105 2,0622:00PM 1,105 1,170 2,275 - - - - - - - - - - - - - - - - - - 1,105 1,170 2,2753:00 PM 1,356 1478 2,836 - - - - - - - - - - - - - - - - - 1,358 1,478 2,8364:00 PM 1,801 1,626 3,427 - - - - - - - - - - - - 1,801 1,626 3,4275:00PM 2,021 1,275 3,296 - - - - - - - - - - - - - - - 2,021 1,275 3,2966:00 PM 1.353 891 2,244 - - - - - - - - - - 1,353 891 2,2447:00 PM 825 599 1,424 - - - - - - - - - - - - - - - 825 599 1,4248:00PM 724 439 1,163 . - - . - - - - 724 439 1,1639:00 PM 526 298 824 - - - - - - - - - - . 526 298 82410:00PM 356 212 568 - - - - - - - - - - 356 212 56811:00PM 195 137 332 - - - - - - - - - - - - - - 195 137 332
Total 19,496 20,975 40,470 - - - - - - - - - 19,495 20,975 40,470Percent 48% 62% - - - - - - - - - - - 43% 523’o -
1 Mid-week average includes data between Tuesday and Thursday.
Nathan Warren: (720) 646-1008
Vehicle Classification Report Summary
DATA SOLUTIONS
Location: PLATTE AVE WIO SAND CREEK BRIDGECount Direction: Eastbound I WestboundDate Range: 81112017 to 81112017Site Code: 01
FHWA Vehicle Classification Total1 2 3 4 5 6 7 8 9 10 II 12 13 Volume
Study TotalEastbound 162 12,109 4,736 46 1,601 206 0 104 251 135 14 9 122 19,495Percent 0.8% 62.1% 24.3% 0.2% 8.2% 1.1% 0.0% 0.5% 1.3% 0.7% 0.1% 0.0% 0.6% 100%Westbound 91 12,759 5,304 57 1,929 216 0 99 322 109 8 8 73 20,975Percent 0.4% 60.8% 25.3% 0.3% 9.2% 1.0% 0.0% 0.5% 1.5% 0.5% 0.0% 0.0% 0.3% 100%Total 253 24,868 10,040 103 3,530 422 0 203 573 244 22 17 195 40,470Percent 0.6% 61.4% 24.8% 0.3% 8.7% 1.0% 0.0% 0.5% 1.4% 0.6% 0.1% 0.0% 0.5% 100%
FHWA Vehicle ClassificationClass 1 - Motorcycles Class 8 - Four or Fewer Axle Single-Trailer TrucksClass 2 - Passenger Cars Class 9 - Five-Axle Single-Trailer TrucksClass 3 - Other Two-Axle, Four-Tire Single Unit Vehicles Class 10 - Six or More Axle Single-Trailer TrucksClass 4 - Buses Class 11 - Five or fewer Axle Multi-Trailer TrucksClass 5 - Two-Axle, Six-Tire, Single-Unit Trucks Class 12 - Six-Axle Multi-Trailer TrucksClass 6 - Three-Axle Single-Unit Trucks Class 13 - Seven or More Axle Multi-Trailer TrucksClass 7 - Four or More Axle Single-Unit Trucks
Nathan Warren: (720) [email protected]
PLATTE AVE WIO SAND CREEK BRIDGE8/112017 to 81112017
01
FHWA Vehicle Classification TotalTime 1 2 3 4 5 6 7 8 9 10 11 12 13 Volume
12:00AM 0 85 11 0 8 0 0 0 0 1 0 0 0 1051:00AM 3 59 16 0 5 0 0 1 0 0 0 0 0 842:00AM 0 44 11 0 13 0 0 0 0 0 0 0 0 683:00AM 0 40 10 1 1 0 0 0 2 1 0 0 0 554:00AM 2 77 19 1 17 1 0 2 5 1 0 0 0 1255:00AM 1 234 78 1 47 1 0 2 5 5 0 0 0 3746:00AM 9 839 311 0 132 7 0 7 12 8 0 1 4 1,3307:00AM 14 1,048 353 6 109 13 0 6 20 21 2 2 9 1,6058:00AM 4 544 285 4 93 17 0 3 17 9 0 0 5 9819:00AM 4 446 211 2 92 16 0 5 18 9 3 0 14 82010:00AM 8 441 188 6 77 20 0 6 30 5 1 0 8 79011:00AM 9 478 228 5 83 15 0 7 22 7 1 0 9 86412:00PM 13 641 259 5 90 16 0 9 15 12 0 0 13 1,0731:00PM 8 552 254 3 86 10 0 5 23 8 2 0 6 9572:00PM 9 625 306 4 91 26 0 7 22 9 0 2 4 1,1053:00PM 13 806 344 3 105 21 0 13 25 8 0 2 18 1,3584:00PM 16 1,130 467 1 128 16 0 8 13 9 2 0 11 1,8015:00PM 15 1,339 468 2 141 14 0 11 9 9 0 1 12 2,0216:00 PM 10 896 319 0 101 6 0 2 4 5 1 1 8 1,3537:00 PM 9 547 189 0 65 4 0 4 4 3 0 0 0 8258:00 PM 7 480 175 0 52 1 0 3 1 4 0 0 1 7249:00 PM 3 363 121 0 33 1 0 1 2 1 1 0 0 52610:00 PM 3 254 75 0 20 1 0 1 1 0 1 0 0 35611:00PM 2 141 38 0 12 0 0 1 1 0 0 0 0 195Total 162 12,109 4,736 46 1,601 206 0 104 251 135 14 9 122 19,495Percent 0.8% 62.1% 24.3% 0.2% 8.2% 1.1% 0.0% 0.5% 1.3% 0.7% 0.1% 0.0% 0.6%
Nathan Warren: (720) 646-1008
Location:Date Range:Site Code:
Tuesday, August 1, 2017Eastbound
DATA SOLUTIONS
Location: PLATTE AVE WIO SAND CREEK BRIDGEDate Range: 8/112017 to 811!2017Site Code: 01
Tuesday, August 1, 2017DATA SOLUTIONS
Westbound
FHWA Vehicle Classification TotalTime 1 2 3 4 5 6 7 8 9 10 11 12 13 Volume
12:00AM 0 47 8 0 7 1 0 0 2 0 1 0 0 661:00AM 1 36 6 0 3 0 0 1 2 0 0 0 0 492:00AM 1 22 14 0 2 2 0 0 1 0 0 0 0 423:00AM 0 57 28 0 11 2 0 1 2 0 0 0 0 1014:00AM 1 119 39 0 17 4 0 0 4 0 0 0 0 1845:00AM 10 456 187 0 65 9 0 0 11 3 0 1 0 7426:00AM 7 1007 424 2 151 15 0 4 20 7 1 2 3 1,6437:00AM 7 1417 601 5 220 4 0 6 18 4 1 1 8 2,2928:00AM 3 1038 423 4 154 14 0 4 22 11 0 1 4 1,6789:00AM 5 806 337 5 122 14 0 9 21 13 1 0 6 1,33910:00AM 5 753 316 3 114 11 0 6 20 5 0 1 7 1,24111:00AM 5 721 296 6 105 12 0 10 22 10 0 0 5 1,19212:00PM 2 674 306 4 111 14 0 8 37 7 2 0 11 1,1761:00PM 4 593 283 7 148 20 0 6 33 5 0 0 6 1,1052:00PM 10 653 302 5 123 27 0 15 22 7 1 0 5 1,1703:00PM 3 896 353 7 136 28 0 4 28 14 0 1 8 1,4784:00PM 7 1,014 392 7 136 20 0 12 21 14 0 0 3 1,6265:00PM 7 792 339 0 98 11 0 8 11 3 0 0 6 1,2756:00 PM 5 573 229 1 63 5 0 2 8 3 0 1 1 8917:00 PM 5 372 159 0 57 1 0 0 4 1 0 0 0 5998:00PM 2 272 113 0 40 1 0 3 5 2 1 0 0 4399:00 PM 1 200 68 1 23 0 0 0 5 0 0 0 0 29810:00PM 0 153 41 0 16 1 0 0 1 0 0 0 0 21211:00PM 0 88 40 0 7 0 0 0 2 0 0 0 0 137Total 91 12,759 5,304 57 1,929 216 0 99 322 109 8 8 73 20,975Percent 0.4% 60.8% 25.3% 0.3% 9.2% 1.0% 0.0% 0.5% 1.5% 0.5% 0.0% 0.0% 0.3%