22 Aug 2006 1
Ageing studies: the Miracle
• HV training
22 Aug 2006 2
Irradiation after brief HV training
Conditions:Flow: Ar/CO2 70/30 2mCu, 90Sr sourceHV training at 1850 V for ~1 hour,
only for upper half (channels 33-64 in the plots) ~1 μA / wire for 1 hour
Conclusions: Smaller damage at trained half?
Ratio of scans from Aug17 / Aug16
Gas flow
Ch 33-64 HV trained at 1850V
22 Aug 2006 3
“Non-gentle” extended HV training
Procedure:Only half the module is put under HV, to keep a reference
IV-curve for positive bias, without irradiation
HV training/processing for 20 hrs
Current per wire per cm:Similar to current during irradiation
22 Aug 2006 4
Large recovery after HV training (1)
After HV training
Before HV training
Ch 33-64 trained at 1870V
Ratio
What is this??Lower gain in trained area?
22 Aug 2006 5
Large recovery after HV training (2)
Nottrained
Trained
No recovery at all??
Recovery
Some spots are fully recovered, other spots are not recovered at all
22 Aug 2006 6
Large recovery after HV training (3)
Nottrained
Trained
Some spots are fully recovered, other spots are not recovered at all
22 Aug 2006 7
Large recovery after HV training (4)
Zoom in
What is the small increase in gainin the untrained region (ch29-32) ?
Possibly artificial effect from current meter:region with very large damage, so small current variation is large fractional difference
22 Aug 2006 8
HV training prevents ageing!
No damage in trained region!!
(A bit of extra gain loss in previously heavily irradiated spot?)
22 Aug 2006 9
Conclusions“Non-gentle” extended HV
training
HV trainingHalf module for 20 hrs at 1870V without
irradiation
Conclusions1) Large recovery of damaged area
after 20 hrs at 1870V2) Not all damaged area recovered3) Small, uniform, gain decrease over
full half-module area 4) HV training prevents ageing
HV training
Damage of some wires disappear:
22 Aug 2006 10
HV training 1910V
Procedure:Only half the module is put under HV, to keep a reference
IV-curve for positive bias, without irradiation
HV training/processing for 20 hrs
22 Aug 2006 11
Full recovery after HV training at 1910V
After 2nd HV training
Before 2nd HV training
Ch 33-64 trained at 1910V
Ratio
What is this??Lower gain in trained area?
22 Aug 2006 12
Full recovery after HV training at 1910V
Nottrained
Trained
Finally, *all* spots recovered!
22 Aug 2006 13
HV training prevents ageing!
No damage in trained region!!
(A bit of extra gain loss in previously heavily irradiated spot?)
What happens with ch21 – ch32?
What is this??Higher gain in trained area?
22 Aug 2006 14
IV curves withpos and neg bias
Conditions:Flow: Ar/CO2 70/30, 20 l/hrNo irradiation32 channels of module 3AMeasure total current of 32 channels using the CAEN power supply
Conclusions: Normal, pos, bias shows dropping current, indicating some processing
17 Aug, first try
19 Aug, after training at 1870V
21 Aug, negative bias
22 Aug 2006 15
HV training prevents ageing: irradiate longer…
HV trained
Gas flow20 hrs
Conditions:Flow: Ar/CO2 70/30, 20 l/hrIrradiation: 2mCu, 90Sr sourceAfter HV training procedure ch33-64
20 hrs at 1870 V 20 hrs at 1910 V
Conclusions: Trained wires show small gain drop
340 hrs
179 hrs
292 hrs
22 Aug 2006 16
HV training prevents ageing: irradiate longer…
HV trained
Gas flow
Conditions:Flow: Ar/CO2 70/30, 20 l/hrIrradiation: 2mCu, 90Sr sourceAfter HV training procedure ch33-64
20 hrs at 1870 V 20 hrs at 1910 V
Conclusions: Trained wires show smaller gain drop
292 hrs
Zoom scale:
22 Aug 2006 17
HV training prevents ageing:compare the 2 halves
22 Aug 2006 18
HV training slows down ageing (1d-plots)
Nottrained
Trained
22 Aug 2006 19
Repair damage AGAINGas flow
Conditions: Flow: Ar/CO2 70/30, 20 l/hr Irradiation: 2mCu, 90Sr source Sequence:
1) HV training ~40 hrs 1870 and 1920V2) Irradiate 340 hrs3) HV training 18 hrs 1910 V
Conclusions: A second HV training helps again 340 hrs
180 hrs
After HV
Lower?
2nd HV training
1st HV training
NB: 400 hrs ~ 1.5 106 s ~ 2 months nominal LHC 340+70 hrs
22 Aug 2006 20
Flat Gold Surface prevents 2CO+O22CO2, hence keeps
O2?
• “It can act as a catalyst and transform carbon monoxide (CO) to carbon dioxide (CO2) when it comes in the form of tiny pieces, called nano-particles.” (http://www.physorg.com/news70200836.html)
• “Particles of gold have been reported to be very active in various oxidation reactions. The particle size greatly influences the catalytic activity of gold particles and with decreasing particle size, the activity increases.” (http://idw-online.de/pages/de/news165204)
22 Aug 2006 21
HV training 2nd module (mod30B)
HV training, at 1870V HV training, at 1930V
22 Aug 2006 22
HV trainings in Mod 30B
Date HV (V)
Time
Effect 20mCu slit
Effect 2mCu point
31 Aug
1870 5 22/32 cured -
31 Aug
1930 14 100% cured
-
5 Sep 1950 15 100% cured
No effect
6 Sep 1950 4 - 1/8 wire ok
6 Sep 1930 16 - No effect
Big spot cured
Big spot cured,small spot not
Still not
22 Aug 2006 23
Confirm procedure: Mod 30B
Irradiation: 20mCu, 90Sr slit sourceSequence:
1) Irradiate 20 hrs 2) HV training 1870V (5hr)+1930V (14hr)3) Irradiate 63 hrs 4) HV training 1950V (16hr)+1930V (16hr)5) Irradiate x hrs
Conclusions: Trained wires show small gain drop
1) 20 hrs, 20mCu
2) After HV
3a) 20 hrs, 20mCu
3b) 63 hrs, 20mCu
4) After HV
5) re-irradiate: 86 hrs, 20 mCu
This damage isno peanuts…
22 Aug 2006 24
Conditions: Flow: Ar/CO2 70/30, 20 l/hr Irradiation: 2mCu, 90Sr source Sequence:
1) HV training ~40 hrs 1870 and 1920V
2) Irradiate 340 hrs3) HV training 18 hrs
1910V4) Irradiate 340 hrs
Conclusions: Damage reappears
similarly the 2nd time Max damage ~10%
250hrs after HV
Re-apperance of Damage
22 Aug 2006 25
Imax(nA)
Time (hr)
Charge (mC)
Damage
Radius (cm)
I at Radius (nA)
2.5 166 1.5 35% 0 (2.5)
125 22 10 30% 2 7
340 19 23 30% 3 9
Recap: Damage vs
Intensity
Max damage at 5-10 nA
22 Aug 2006 26
Repair damage AGAINGas flow
Conditions: Flow: Ar/CO2 70/30, 20 l/hr Irradiation: 2mCu, 90Sr source Sequence:
1) HV training ~40 hrs 1870 and 1920V2) Irradiate 340 hrs3) HV training 18 hrs 1910 V
Conclusions: A second HV training helps again
340 hrs
After HV
After HV
Lower?
2nd HV training
1st HV training
NB: 700 hrs ~ 2.5 106 s ~ 4 months nominal LHC
340+350 hrs
Rel
.gai
n
3rd HV training
Lower??
22 Aug 2006 27
In the Meanwhile:Study long term
flushing
Conclusions:• Module 30 follows initial pattern from mod 2• What happened with module 2 ??
• Briefly opened when moved from setup to setup
Mod Date Loc I(nA) Time (hrs)
1 2A 22Jun cleanroom
230 19
2 2A 28Jun cleanroom
160 19
3 2A 4Jul cleanroom
200 21
4 2A 27Jul cleanroom
200 20
5 2A 15Aug
cleanroom
170 19
6 2A 28Aug
cleanroom
180 20
7 2A 24Sep cleanroom
180 21
Module 63
36.2 m3
Compare to result from Heidelberg:
100 days
???
22 Aug 2006 28
Damage vs Time(module 3)
History: 21Mar – 12Apr:
28Mar-11Apr: opened module15Apr – 23May:
25Apr-10May: played with water bottle10May-15May: module not connected
23May – 19Jun: 6Jun: Change Ar bottle 6Jun – 19 Jun: Addition of O2
19Jun-15Aug20Jun-14Jul: module not connected
Mod
Date Loc I(nA)
Time (hrs)
1 3B 18Jan cleanroom
190 15
2 3B 23Feb
Lab 150 15
3 3B 21Mar
Lab 150 21.5
4 3B 12Apr
Lab 150 15
5 3A 15Apr
Lab 180 23
6 3A 23May
Lab 140 22
7 3A 19Jun Lab 150 16
8 3A 15Aug
Lab 150 20
28Mar: opened moduleduring 14days
10May: opened moduleduring 5days
6Jun: flushed with 4% O2 for 13days
20Jun: opened moduleduring 24days