16
24-Port Gigabit with 4 Optional 10G Slots Layer 3 Managed Stackable Switch XGS3-24042 / XGS3-24242 Quick Installation Guide

24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

24-Port Gigabit with 4 Optional 10G Slots

Layer 3 Managed Stackable Switch

XGS3-24042 / XGS3-24242

Quick Installation Guide

Page 2: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

Table of Contents

1. Package Content ......................................................................................... 3

2. Switch Management .................................................................................... 4

3. Requirements ............................................................................................. 5

4. Terminal Setup ........................................................................................... 6

5. Logon on the Console ................................................................................. 7

6. ConfigureIPAddress .................................................................................. 8

7. Telnet Management ....................................................................................10

8. Start Web Management ..............................................................................11

9. Set 100Base-FX for SFP Port ......................................................................12

10.UseCopperInterfaceonComboPort ..........................................................13

11.SavetheConfiguration ..............................................................................14

12.LogintheManagedSwitch .........................................................................15

13. Customer Support .....................................................................................16

Page 3: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

3

1. Package ContentThankyouforpurchasingPLANETLayer3IPv6/IPv4ManagedSwitch,XGS3-24042/XGS3-24242.Termsof“Managed Switch”meanstheSwitchmentionedtitledinthecoverpageofthisquickinstallationguide.

Open the box of the Managed Switch and carefully unpack it. The box shouldcontain the following items:

TheXGS3ManagedSwitchx1 l

ThisQuickInstallationGuidex1 l

User’s Manual CD x 1 l

RJ-45-to-DB9 Console Cable x 1 l

PowerCordx1 l

Rubber Feet x 4 l

TwoRack-mountingBracketswithAttachmentScrewsx1 l

SFPDustCapsx4(forXGS3-24042) l

SFPDustCapsx24(forXGS3-24242) l

If any item is found missing or damaged, please contact your local reseller forreplacement.

Page 4: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

4

2. Switch ManagementTo setup the Managed Switch, the user needs to configure the Managed Switchfor network management. The XGS3 Managed Switch provides two managementoptions: Out-of-Band managementandIn-Band management.

Out-of-Band ManagementOut-of-band management is the management through Console interface.Generally, the user will use out-of-band management for the initial switch configuration,orwhenin-bandmanagementisnotavailable.

IMPORTANT!The Managed Switch is shipped without IP address assigned bydefault. User must assign an IP address to the Managed SwitchviatheConsole interfacetobeabletoremoteaccesstheManagedSwitch through Telnet or HTTP.

In-Band ManagementIn-bandmanagement refers to themanagement by login to the Managed SwitchusingTelnet,HTTP,orusingSNMPmanagementsoftwaretoconfiguretheManagedSwitch. In-band management enables management of the Managed Switch forsomedevicesattached to theSwitch. Followingproceduresare required toenableIn-bandmanagement:

1. Logon Console

2.Assign/ConfigureIPAddress

3. Create a remote login account

4.EnableHTTPorTelnetserverontheManagedSwitch

In the casewhen in-bandmanagement fails due toManagedSwitch configurationchanges, out-of-bandmanagement canbeused for configuring andmanaging theManagedSwitch.

Page 5: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

5

3. RequirementsThe Managed Switch provide remote login interface for manage; the followingequipments are necessary for further management.

Workstation running Windows XP/2003/Vista/Windows 7, MAC OS X, Linux,Fedora,Ubuntuorotherplatform.

Serial Port connect(Terminal)

AboveWorkstationwithCOMPort(DB9)orUSB-to-RS-232converter.

Above Workstation has installed with terminal emulator, such as HyperTerminalincludedinWindowsXP/2003/WindowsVista.

Serial cable:One end attach to theRS-232 serial port, the other end to theConsoleportoftheManagedSwitch.

Ethernet Port connect

AboveWorkstationwithrunningOScompatiblewithTCP/IPprotocols.

AboveWorkstationinstalledwithEthernetNIC(NetworkCard).

Networkcables-Usestandardnetwork(UTP)cableswithRJ-45connectors.

AboveWorkstationhasinstalledwithWEBBrowserandJAVAruntimeenviron-ment Plug-in.

Note

It is recommended touse InternetExplore7.0orabove toaccessthe Managed Switch. If theWeb interface of the Managed Switchis not accessible, please turn off the anti-virus software or firewallthen try again.

Page 6: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

6

4. Terminal SetupTo configure the system, connect a serial cable to a COM port on a PC or notebookcomputerand toserial (console)portof theXGS3ManagedSwitch.Theconsole port of theManaged Switch is DCE already, so that you can connect theconsoleportdirectlythroughPCwithouttheneedofNullModem.

RJ-45 Type Serial Port9600,8,n,1

XGS3 Layer 3Managed Switch

RJ-45 DB9 RS-232 cableSerial Port

PC / Workstation withTerminal emulation software

Figure 4-1 XGS3 Managed Switch Console connection

A terminal program is required to make the software connection to the XGS3ManagedSwitch.Windows’Hyper Terminal programmaybeagood choice. TheHyperTerminalcanbeaccessedfromtheStart menu.

1. Click STARTmenu,thenPrograms, AccessoriesandthenHyper Terminal.

2.TypeanameforopeningHyperTerminal,suchas“COM1_9600”.

3.When the following screen appears, make sure that the COM port should beconfiguredas:

Baud:9600 l

Parity:None l

Data bits : 8 l

Stop bits : 1 l

FlowControl:None l

Figure 4-2 Hyper Terminal COM port configuration

Page 7: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

7

5. Logon on the ConsoleOnce the terminal has connected to the device, power on the XGS3 ManagedSwitch,theterminalwilldisplaythatitisrunningtestingprocedures.

Then, the followingmessageasks the loginusernameandpassword.The factorydefault user name and password as following and the login screen in Figure 5-1appears.

Username: admin

Password:admin

Figure 5-1 XGS3 Managed Switch Console Login screen

The user can now enter commands to manage the Switch. For a detaileddescriptionforthecommands,pleaserefertothefollowingchapters.

Note

1.Forsecurityreason,pleasechangeandmemorizethenewpass-wordafterthisfirstsetup.

2.Onlyacceptcommandinlowercaseletterunderconsoleinter-face.

Page 8: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

8

6.ConfigureIPAddressThe IP address configuration commands for VLAN1 interface are listed below.Before in-band management, the Managed Switch must be configured with anIP address by out-of-band management (i.e. Console mode), the configurationcommands are as follows (All switch configuration prompts are assumed to be“XGS3-24042”hereafterifnototherwisespecified):

XGS3-24042>

XGS3-24042>enable

XGS3-24042# config

XGS3-24042(config)# interface vlan 1

XGS3-24042(Config-if-Vlan1)# ip address 192.168.1.254 255.255.255.0

ThepreviouscommandwouldapplythefollowsettingsfortheManagedSwitch.

IPv4 Address: 192.168.1.254

Subnet Mask: 255.255.255.0

Figure 6-1 Configure IPv4 address screen

Page 9: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

9

TocheckthecurrentIPaddressormodifyanewIPaddressfortheSwitch,pleaseusetheproceduresasfollow:

Show the current IP address1. On "XGS3-24042#”prompt,enter“show ip interface brief”.

2.ThescreendisplaysthecurrentIPaddress,SubnetMaskandGateway.Asshowin Figure 6-2.

Figure 6-2 Show IP information screen

If the IP is successfully configured, the Managed Switch will apply the new IPaddress setting immediately. You can access theWeb interface of XGS3ManagedSwitchthroughthenewIPaddress.

Note

Ifyoudonotfamiliarwithconsolecommandortherelatedparam-eter,enter“help”anytimeinconsoletogetthehelpdescription.

Page 10: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

10

7. Telnet ManagementLogin to the Telnet configuration interface. Valid login name and password arerequired,otherwisetheManagedSwitchwill rejectTelnetaccess.This isamethodto protect the Managed Switch from unauthorized access. As a result, whenTelnet is enabled for configuring and managing the Managed Switch, usernameand password for authorized Telnet users must be configured with the followingcommand:

username <username> privilege <privilege> [password (0|7) <password>]

Privilege option must exist and just is 15. Assume an authorized user in theManaged Switch has a username of “admin”, and password of “admin”, theconfigurationprocedureshouldlikethefollowing:

XGS3-24042>enable

XGS3-24042#config

XGS3-24042(config)# username admin privilege 15 password 0 admin

Enter valid login name and password in the Telnet configuration interface, Telnetuser will be able to enter the Managed Switch’s CLI configuration interface. Thecommands used in the Telnet CLI interface after login is the same as that in theConsole interface.

Figure 7-1 Telnet Configuration Interface

Page 11: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

11

8. Start Web ManagementFor configuring the IP address on the Managed Switch through out-of-bandmanagement,seethetelnetmanagementchapter.

To enable the Web configuration, users should type the CLI command IP httpserverintheglobalmodeasbelow:

XGS3-24042>enable

XGS3-24042# config

XGS3-24042(config)# ip http server

The Managed Switch provides a built-in browser interface. You can manage itremotely by having a remote host with Web browser, such as Microsoft InternetExplorer,MozillaFirefox,GoogleChromeorAppleSafari.

XGS3 Managed Switch

RJ-45/UTP-Cable

PC / Workstation

IP Address:192.168.1.x

IP Address:192.168.1.254

Figure 8-1 IP Management diagram

Note

Please refer to Chapter 5 – CONFIGURE IP ADDRESS for the IPv4IPaddresssettingontheXGS3ManagedSwitch.

The following shows how to start up the Web Management of the ManagedSwitch, please note the Managed Switch is configured through an Ethernetconnection, please make sure the manager PC must be set on the same IP subnet address.

For example, the IP address of the Managed Switch is configured with192.168.1.254, then the manager PC should be set at 192.168.1.x (where x is a number between 1 and 253, except 254), and the default subnet mask is255.255.255.0.

Page 12: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

12

9. Set 100Base-FX for SFP PortThe XGS3 Managed Switch supports both 1000Base-X and 100Base-FX SFPtransceiverbymanual settingand thedefaultSFPport speed is set to1000Mbps.To establish the fiber connection with 100Base-FX SFP transceiver, the followingcommandconfigurationisrequired:

XGS3-24042#config

XGS3-24042(config)#interface ethernet 1/0/21-24

XGS3-24042(config-if-port-range)#speed-duplex force100-fx

Figure 9-1 Set 100Base-FX screen

Page 13: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

13

10.UseCopperInterfaceonComboPortThe XGS3 Managed Switch’s combo port has SFP and copper interface and thedefault combo port type is SFP port only. To establish the combo port connectionwithcopperinterface,thefollowingcommandconfigurationisrequired:

XGS3-24042#config

XGS3-24042(config)#interface ethernet 1/0/21-24

XGS3-24042(config-if-port-range)#media-type copper

Figure 10-1 Use copper interface screen

Page 14: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

14

11.SavetheConfigurationInswitch, the runningconfigurationfilestores in theRAM. In thecurrentversion,the running configuration sequence running-config can be saved from theRAM toFLASHbywritecommandorcopy running-config startup-configcommand,sothat the running configuration sequence becomes the start up configuration file,whichiscalledconfigurationsave.

XGS3-24042>enable

XGS3-24042# copy running-config startup-config

Figure 11-1 Copy running-config startup-config screen

Page 15: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

15

12.LogintheManagedSwitch1.Use Internet Explorer 7.0 or above Web browser, enter IP address

http://192.168.1.254 (that you have just set in console) to access theWebinterface.

2.When the following dialog box appears, please enter the configured user name“admin”andpassword“admin”(or theusername/passwordyouhavechangedviaconsole).TheloginscreeninFigure12-1appears.

Figure 12-1 Login screen

3.Afterenteringthepassword,themainscreenappearsasFigure10-2.

Figure 12-2 Web Main Screen of XGS3 Managed Switch

4.TheSwitchMenuon the left of theWebpage letyouaccessall the commandsandstatisticstheSwitchprovides.

Now, you can use the Web management interface to continue the Switchmanagementormanage theManagedSwitchby console interface.Please refer tothe user manual for more.

Page 16: 24-Port Gigabit with 4 Optional 10G Slots Layer 3 ... - PLANET

16

13. Customer SupportThankyouforpurchasePLANETproducts.YoucanbrowseouronlineFAQresourceatthePLANETWebsitefirsttocheckif itcouldsolveyouissue.Ifyouneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.

PLANETonlineFAQ:http://www.planet.com.tw/en/support/faq.php?type=1

Switchsupportteammailaddress:[email protected]

Copyright © PLANET Technology Corp. 2012.Contents subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.