For further help regarding installation visit lumino.lighting OPTIONAL ACCESSORIES VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin VECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin ESSENTIAL ACCESSORIES IMV10S-R1801 3 1 2 3 x per metre 24 VDC Max screw Gauge No.4 4 CLICK a. c. b. • Damage will be caused by incorrect input voltage or short circuit • Ensure access and sufficient free moving air space around products and drivers • Products and power supply gear must not be live wired • Protect products from dust & paint during installation and use • Shielded pair of cables will be required for dimming control signal if applicable • Plan for loads, driver locations, dimming and suitable cable prior to installing • For technical assistance contact your local Lumino distributor. • Use only with class 2 power unit to UL 1310 standard • Use only with maximum output 24VDC voltage Class 2 power unit ! TURN OFF POWER! COUPER LE COURANT! STROM ABSHALTEN! CORTE CORRIENTE! CHECK THE WALL! VËRIFIER LE MUR! DIE WAND ÜBERPRÜFEN! COMPRUEBE LA PARED! Check! V10S VECTOR INSTALLATION MANUAL V10S-MA620-R1 V10S Rotation Mount PC White (x20) V10S-MA600-R1 V10S Rotation Mount PC White (x100) V10S-MA900-R1 V10S Rotation Mount PC White (x500)

24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin VECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin ESSENTIAL ACCESSORIES IMV10S-R1801

  • Upload
    lekhue

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin VECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin ESSENTIAL ACCESSORIES IMV10S-R1801

For further help regarding installation visit lumino.lighting

OPTIONAL ACCESSORIES

VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 PinVECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin

ESSENTIAL ACCESSORIES

IMV10S-R1801

31

23 x per metre

24 VDC

Max screwGauge No.4 4

CLICK

a. c.b.

• Damage will be caused by incorrect input voltage or short circuit• Ensure access and sufficient free moving air space around products and drivers• Products and power supply gear must not be live wired• Protect products from dust & paint during installation and use• Shielded pair of cables will be required for dimming control signal if applicable• Plan for loads, driver locations, dimming and suitable cable prior to installing• For technical assistance contact your local Lumino distributor.• Use only with class 2 power unit to UL 1310 standard• Use only with maximum output 24VDC voltage Class 2 power unit

!

TURN OFF POWER!COUPER LE COURANT!STROM ABSHALTEN!CORTE CORRIENTE!

CHECK THE WALL!VËRIFIER LE MUR!DIE WAND ÜBERPRÜFEN!COMPRUEBE LA PARED!

Check!

V10SVECTOR INSTALLATION MANUAL

V10S-MA620-R1 V10S Rotation Mount PC White (x20)V10S-MA600-R1 V10S Rotation Mount PC White (x100)V10S-MA900-R1 V10S Rotation Mount PC White (x500)

Page 2: 24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin VECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin ESSENTIAL ACCESSORIES IMV10S-R1801

For further help regarding installation visit lumino.lighting

Straights / Corners / Curves Concealed Coving

50mm

min.

120m

mm

in.

40°

175

140 80

475

40°

175

140

20°

70 30°

70

Solidedge / Shelving

V10SVECTOR INSTALLATION MANUAL

Page 3: 24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin VECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin ESSENTIAL ACCESSORIES IMV10S-R1801

V10SVECTOR WIRING GUIDE

For further help regarding installation visit lumino.lighting

24VDCDRIVER

See guide forcable length

VectorVectorVector

<6W/m up to 12m<12W/m up to 6m

Standard wiring arrangementMAX CABLE LENGTH GUIDE 24VDC power supply*

0.3mm²22AWG

0.8mm²18AWG

1.3mm²16AWG

2.0mm²14AWG

VectorLength

VectorCurrent

VectorPower

32m16m10m8m6m5m4m3m3m2m2m1m

50m50m50m50m42m36m31m27m23m20m18m16m

50m50m50m50m50m50m45m41m37m33m30m28m

50m50m50m50m50m50m50m50m50m50m47m44m

1m / 3.3’2m / 6.6’3m / 9.8’4m / 13.1’5m / 16.4’6m / 19.7‘7m / 23’ 8m / 26.2‘9m / 29.5’10m / 32.8’11m / 36’12m / 39.3’

6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft6W/m 1.7W/ft

0.250.500.751.001.251.501.752.002.252.502.753.00

16m8m5m3m2m1m

50m50m36m27m20m16m

50m50m50m41m33m28m

50m50m50m50m50m44m

1m / 3.3’2m / 6.6’3m / 9.8’4m / 13.1’5m / 16.4’6m / 19.7’

12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft12W/m 3.7W/ft

0.501.001.502.002.503.00

*Cable lengths are based on average resistance for typical copper cables. Cable characteristics may vary acording to manufacturer, temperature, copper purity, connections etc.

• Installation must be carried out by qualified electrician.

• Electrical work to be conducted in accordance with local regulations.

• Power must be disconected prior to installation work.

• Ensure free-moving air space around leds and drivers.

• Protect the leds from dust and paint during installation and use.

• Plan for loads, driver locations, cables sizes etc prior to installation.

• Shielded control pair required for dimming signal wires.

• Incorrect voltage, reverse polarity or short circuit will cause damage.

Installers must ensure voltage drop does not exceed 5%.

Driver protection circuitry must not be relied upon to protect secondary 24VDC electrical circuits from damage caused by overcurrent or short circuit. DC fuses or DC electronic circuit breakers are recommended to provide additional protection.

Installers must ensure EMI emissions do not exceed local regulated limits.

Shielded cables and ferrite coils can be used where applicable. Vector interconnector cables are 22AWG.

Reduce max. cable lengths by 10% if dimming.

EMI Emission24 VDC

Use 24VDC drivers with overload and short-circuit protection. Rate drivers for at least 10% above load.

USA & Canada:Use only with Class 2 power unit to UL1310 standard. Use only with maximum output 24VDC voltage Class 2 power unit.

Constant voltage LED drivers can have high inrush current at power-on. Driver inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistant problem an inrush suppressor may be required.

Page 4: 24 VDC - Lumino Lighting · VECA-CA025-R1 250mm Inter connector lead M&F Standard 2 Pin VECA-CA100-R1 1000mm Inter connector lead M&F Standard 2 Pin ESSENTIAL ACCESSORIES IMV10S-R1801

V10SMAX LED LENGTH GUIDE (EXCLUDING CABLE)

lumino.lighting/support

6W/m1.8W/ft

12W/m3.7W/ft

9m / 29’16m / 52’24m / 78’

4.5m / 15’8m / 26‘12m / 39’

P24-060-DALP24-100-DALP24-150-DAL

TRIAC DIMMING

0-10V DIMMING

DALI DIMMING

6W/m1.8W/ft

12W/m3.7W/ft

16m / 52’32m / 105’

8m / 26‘16m / 52’

P24-100-PHP24-200-PH

6W/m1.8W/ft

12W/m3.7W/ft

9m / 29’16m / 52’19m / 62’32m / 105’

4.5m / 15‘8m / 24’9.5m / 31’16m / 52’

P24-60-D10P24-100-D10P24-120-D10P24-200-D10

continue up to max. cable and load limits24VDCDRIVER

Max Total LED Length (see table)

VectorVectorVector VectorVectorVector

120VAC / 230VACTRIAC leading-edgephase cuttingdimmed supply

0-10v dimming signal input

continue up to max. cable and load limits24VDCDRIVER

Max Total LED length (see table)

VectorVectorVector VectorVectorVector

DALI dimming signal input

continue up to max. cable and load limits24VDCDRIVER

Max Total LED length (see table)

VectorVectorVector VectorVectorVector

Total LED LengthTriac Driver

Total LED Length0-10V Driver

Total LED LengthDALI Driver

*See guide forcable length

*See guide forcable length

*Cable length from Driver to LED, see Max Cable Length Guide.’

*See guide forcable length

<6W/m up to 12m<12W/m up to 6m

<6W/m up to 12m<12W/m up to 6m

<6W/m up to 12m<12W/m up to 6m

<6W/m up to 12m<12W/m up to 6m

<6W/m up to 12m<12W/m up to 6m

<6W/m up to 12m<12W/m up to 6m