437 FAP WALL THERMOSTATS WALL THERMOSTATS ROUND SERIES 24 VOLT HEATING/COOLING THERMOSTAT AND SUB- BASES... SINGLE STAGE THERMOSTATS FOR HEATING ONLY WITHOUT SUB-BASE QUIET SPDT MERCURY SWITCH HEATING ANTICIPATOR: .1-1.2 AMP ADJ INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING SCREWS 1H/1C WITH SUB-BASES LISTED BELOW SUB-BASES PROVIDE MOUNTING AND MANUAL SWITCHING FOR HH01AD060 FAN SWITCH: ON-AUTO COOLING ANTICIPATOR: FIXED P/N LOGO HH01AD060 HONEYWELL HH621201 BRYANT HH621401 PAYNE P/N GENERAL USE AUTO FAN SYSTEM SWITCH HH93AZ050 GAS/ELECTRIC SPLIT SYSTEMS & SELF CONTAINED COOLING ONLY COOL OFF HEAT HH93AZ051 HP, COOLING WITH ACCESSORY ELECTRIC HEAT HEATING & COOLING COOL OFF HEAT HH93AZ053 COOLING ONLY SYSTEM COOLING ONLY COOL OFF HEAT HH93AZ055 COOLING ONLY SYSTEM COOLING ONLY COOL OFF ONLY P564 STANDARD SERIES 24 VOLT HEATING/COOLING THERMOSTAT... SINGLE STAGES FOR USE ON: QUIET SPDT MERCURY BULB SWITCH HEATING ANTICIPATOR: .18-10 AMP P/N LOGO GENERAL USE AUTO FAN OPERATION HH07AT184 CARRIER GAS/ELECTRIC SPLIT SYSTEMS AND SELF-CONTAINED COOLING ONLY EXTRA HTG. & CLG. TERMINALS: HEATING ONLY HH07AT183 BDP GAS/ELECTRIC SPLIT SYSTEMS AND SELF-CONTAINED COOLING ONLY EXTRA HTG. & CLG. TERMINALS: HEATING ONLY HH641601 HONEYWELL GAS/ELECTRIC SPLIT SYSTEMS AND SELF-CONTAINED COOLING ONLY EXTRA HTG. & CLG. TERMINALS: HEATING ONLY P563

24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

Embed Size (px)

Citation preview

Page 1: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

437

FAP WALL THERMOSTATS

WALL THERMOSTATSROUND SERIES

24 VOLT HEATING/COOLING THERMOSTAT AND SUB- BASES... SINGLE STAGE

THERMOSTATS

• FOR HEATING ONLY WITHOUT SUB-BASE• QUIET SPDT MERCURY SWITCH• HEATING ANTICIPATOR: .1-1.2 AMP ADJ• INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING

SCREWS• 1H/1C WITH SUB-BASES LISTED BELOW

SUB-BASES

• PROVIDE MOUNTING AND MANUAL SWITCHING FORHH01AD060

• FAN SWITCH: ON-AUTO• COOLING ANTICIPATOR: FIXED

P/N LOGOHH01AD060 HONEYWELLHH621201 BRYANTHH621401 PAYNE

P/NGENERAL

USEAUTOFAN

SYSTEMSWITCH

HH93AZ050GAS/ELECTRIC

SPLIT SYSTEMS &SELF CONTAINED

COOLINGONLY

COOLOFFHEAT

HH93AZ051HP, COOLING

WITH ACCESSORYELECTRIC HEAT

HEATING &COOLING

COOL OFFHEAT

HH93AZ053COOLING ONLY

SYSTEMCOOLING

ONLY

COOL OFFHEAT

HH93AZ055COOLING ONLY

SYSTEMCOOLING

ONLY

COOL OFF

ONLY

P564

STANDARD SERIES24 VOLT HEATING/COOLING THERMOSTAT...SINGLE STAGES

FOR USE ON:

• QUIET SPDT MERCURY BULB SWITCH• HEATING ANTICIPATOR: .18-10 AMP

P/N LOGOGENERAL

USEAUTO FAN

OPERATION

HH07AT184 CARRIER

GAS/ELECTRICSPLIT SYSTEMS

ANDSELF-CONTAINED

COOLING ONLYEXTRA HTG. & CLG.

TERMINALS:HEATING ONLY

HH07AT183 BDP

GAS/ELECTRICSPLIT SYSTEMS

ANDSELF-CONTAINED

COOLING ONLYEXTRA HTG. & CLG.

TERMINALS:HEATING ONLY

HH641601 HONEYWELL

GAS/ELECTRICSPLIT SYSTEMS

ANDSELF-CONTAINED

COOLING ONLYEXTRA HTG. & CLG.

TERMINALS:HEATING ONLY

P563

Page 2: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

438

FAP WALL THERMOSTATS

WALL THERMOSTATSHEAT ONLY THERMOSTAT24 VOLT HEATING/COOLING THERMOSTAT AND SUB-BASES... SINGLE STAGE

THERMOSTAT

• FOR HEATING ONLY WITHOUT SUB-BASE • 1H/1C WITH SUB-BASE LISTED BELOW• QUIET SPDT MERCURY SWITCH• HEATING ANTICIPATOR:.1-1.2 AMP ADJ.• INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING

SCREWS

WITH CARRIER LOGO

SUB-BASE

• PROVIDES MOUNTING AND MANUAL SWITCHING FOR THERMOSTAT

• SYSTEM SWITCH: COOL - OFF - HEAT• FAN SWITCH: ON - AUTO• COOLING ANTICIPATOR: FIXED

FOR USE ON:

P/N: HH01AD040

P/NGENERAL

USE

AUTOFAN

OPERATION

HH93AZ040

GAS ELECTRICSPLIT SYSTEMS

ANDSELF-CONTAINED

COOLINGONLY

P566

SPECIAL HEAT PUMP SERIES24 VOLT HEATING/COOLING THERMOSTATS AND SUB-BASES

THERMOSTAT

• SILENT, DUST-FREE MERCURY SWITCHES• SEPARATE TEMPERATURE SELECTOR ARMS FOR HEATING AND

COOLING• SUB-BASE REQUIRED FOR MOUNTING, AND FOR SYSTEM AND

FAN SWITCHING• PRE-WIRED TO MAKE ELECTRICAL CONTACT WHEN MOUNTED TO

SUB-BASE• COVER HAS TAPPED HOLES FOR LOCKING SCREWS

SUB-BASES

• FOR USE WITH SPECIAL HEAT PUMP THERMOSTAT• PROVIDE WIRING TERMINALS, MOUNTING BASE AND SYSTEM/FAN

SWITCHING• EMERGENCY HEAT INDICATOR LIGHT• MOUNT ON WALL OR HORIZONTAL OUTLET BOX

P/N USE ON SUB-BASESYSTEMSTAGES

H/CANTICIPATORS

HH07AT171HH93AZ175

338QTHEAT PUMPS

ONLYHH93AZ171

1H/1C2H/2C

FIXED

HEATPUMPS

CHANGE-OVER TYPE

SWITCH POSITIONSP/N

SYSTEM FAN

38AND

MISC.

AUTOON,OFFSUPL HT

ON,AUTO

HH93AZ173

MANHT, COOL

SUPL HT, OFFON,

AUTO,HH93AZ175

38SQAND

TECH2000

AUTOSUPL HT,

ON, OFFON,

AUTOHH93AZ183

MANSUPL HT,

HT, OFF, COOLON,

AUTOHH93AZ186

50QTONLY

MANHEAT,COOL

SUPL HT, OFFON,

AUTOHH93AZ171

P567

Page 3: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

439

FAP WALL THERMOSTATS

WALL THERMOSTATS (HONEYWELL)MULTI-STAGE SERIES THERMOSTATS

• 24 VOLT HEATING/COOLING THERMOSTAT• SILENT, DUST FREE MERCURY SWITCHES• SEPARATE TEMPERATURE SELECTOR ARMS FOR HEATING AND

COOLING• SUB-BASE REQUIRED FOR MOUNTING• PRE-WIRED TO MAKE ELECTRICAL CONTACT WHEN MOUNTED TO SUB-BASE• COVER HAS TAPPED HOLES FOR LOCKING SCREWS• ANTICIPATORS:1ST AND 2ND STAGES

HEAT:.1-1.2 AMP ADJUSTABLECOOL:FIXED

• GENERAL USE: LOW VOLTAGE CONTROL OF MULTI-STAGE HEATING, COOLING, AND HEATING-COOLING SYSTEMS INCLUDING HEAT PUMPS

SYSTEM STAGESP/N LOGO

HEAT COOL2 1 HH07AT170 CARRIER LOGO2 2 HH07AT172 CARRIER LOGO1 1 HH07AT174 CARRIER LOGO2 1 HH621603 HONEYWELL LOGO2 2 HH621606 HONEYWELL LOGO1 1 HH621602 HONEYWELL LOGO

MATCHING SUB-BASES

• FOR MULTI-STAGE THERMOSTATS HH07AT170, 172, 174• PROVIDE WIRING TERMINALS, MOUNTING BASE, AND SYSTEM AND FAN SWITCHING MOUNT ON WALL OR HORIZONTAL OUTLET BOX

*A = Fan circuit energized automatically during cooling cycle only.B = Fan circuit energized automatically during cooling and heating cycles.C = Removable jumper for use on two-transformer systems.D = Extra terminal provided for heating circuit.

CHANGEOVER TYPESPECIAL

FEATURES* P/N

AUTOMATIC MANUALSWITCH POSITIONS

SYSTEM FANNONE HEAT COOL AUTO OFF EMER-HEAT NONE ON, AUTO

� � � � � � � � A, F HH93AZ174� � � � � � � A, C, D HH93AZ176� � � � � � � A, C, G HH93AZ177

� � � � � B, C, E, G HH93AZ179� � � � � A, C, E HH93AZ184

P567

E = Extra terminal provided for heating and cooling circuits.

F = Indicator light for emergency heat.G = Indicator for lock-out or lockout.

Page 4: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

440

FAP WALL THERMOSTATS

WALL THERMOSTATS (HONEYWELL)CLOCK THERMOSTAT

• 24 VOLT HEATING/COOLING CLOCK THERMOSTAT• EQUIPPED WITH A RECHARGEABLE BATTERY TO POWER THE

QUARTZ CLOCK• PROVIDES COMPLETE AUTOMATIC HIGH AND LOW• TEMPERATURE CONTROL WITH UP TO THREE SET-

BACK/SET-UP PERIODS• HEAT ANTICIPATOR IS ADJUSTABLE FROM.1 TO 1.2 AMP FOSSIL

FUEL HEATING WALL PLATE IS INCLUDED WITH EACH THERMOSTAT.

THERMOSTAT WITH CARRIER LOGO

SUB-BASES

• MANUAL CHANGEOVER

WALL PLATE

HH99AZ161 – for L.P. Gas

P/N: HH10AD144

P/NFAN

SWITCHSYSTEMSWITCH

HH93AZ160 ON-AUTO HEAT-OFF-COOLSINGLE

TRANSFORMERSYSTEMS

HH93AZ161 ON-AUTO HEAT-OFF-COOLINDEPENDENT

HEAT-COOLSYSTEMS

P562

WALL HUMIDISTAT

Humidistat has outdoor temperatures and corresponding recom-mended humidity settings on face plate for reference.

ADAPTER PLATE

P/N: HL38MG026

P/N: HH92AZ001

• RANGE 10-60%• POSITIVE ON AND OFF

POSITION• ELECTRICAL• RATING:• 50 VA @ 24 VOLT• NYLON SENSING

ELEMENTP591

• THIS ADAPTER PLATE IS USED WITH T87F THERMOSTAT

• COVERS OLD THERMOSTAT MOUNTING MARKS

• 5-1/2 IN. DIAMETER

P565

Page 5: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

441

WHITE-RODGERS WALL THERMOSTATS

.COMFORT-SET 11 DIGITAL THERMOSTATS WITH AUTOMATIC CHANGEOVER

COMFORT-SET 11 DIGITAL THERMOSTATS

• AUTOMATIC HEAT/COOL CHANGEOVER ALLOWS YOU TO SET THE SYSTEM SWITCH IN ONE POSITION ALL YEAR

• SIMULTANEOUS HEATING AND COOLING PROGRAM STORAGE ELIMINATES THE NEED TO REPROGRAM AS THE SEASONS CHANGE

• PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS IN ALL FOUR PROGRAMMING PERIODS

• FOUR SEPARATE TIME/TEMPERATURE SETTINGS IN ALL FOUR PROGRAMMING PERIODS

• COMPUTED EMRTM (ENERGY MANAGEMENT RECOVERY) PROGRAM ALLOWS FOR A HEAD START ON RECOVERY FROM SETBACK OR SETUP PROGRAM TEMPERATURE IS REACHED WHEN DESIRED

• PROGRAMMABLE FAN CONTROL PERMITS CONTINUOUS FAN DURING ANY GIVEN PROGRAM PERIOD

• BACKLIT DISPLAY - ENERGIZES WHENEVER THE KEYPAD OR TEMPERATURE BUTTONS ARE PRESSED

• AUDIO PROGRAM PROMPTING - THERMOSTAT BEEPS TO SIGNAL THAT A CHANGE HAS BEEN MADE

• BATTERY BACKUP CAPABILITY - SUPPLIED WITH THREE “AA” EVEREADY ALKALINE BATTERIES

• KEYPAD LOCKOUT• ELIMINATES NEED FOR ISOLATION RELAYS• COMPATIBLE WITH 3-WIRE ZONE OR 750 MILLIVOLT SYSTEMS• SUITABLE FOR USE ON CENTRAL ELECTRIC HEAT SYSTEMS WHERE BLOWER

IS ENERGIZED BY FAN RELAY ON HEAT AND COOL• REMOTE SENSING - WHEN USED WITH F145-1049 REMOTE SENSOR (ORDER

SEPARATELY)• “HOLD TEMP” KEY PROVIDES MANUAL OVERRIDE OF PROGRAM • °F/ °C DISPLAY• INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING• COMPRESSOR SHORT CYCLE PROTECTION• TEMPERATURE SET-POINTS RESET AND HOLD AT 64° F IN HEATING OR 82° F

COOLING IN CASE OF POWER FAILURE AND NO BATTERY BACKUP• ARM-CHAIR PROGRAMMING• RED LED INDICATOR LIGHT GLOWS WHENEVER THE HEATING, COOLING OR

FAN IS IN OPERATION

P/N: 1F90-0711F97-071

1F90-071 SHOWN

1F97-071 SHOWN

P569

P569

• DUAL PROGRAM STORAGE ON ALL HEAT AND COOL MODELS.• BACKLIT DISPLAY WHEN ANY KEY IS IN USE.• THREE “AA” EVEREADY ALKALINE BATTERIES INCLUDED.• SYSTEM COMPATIBILITY ON 24 VOLT SYSTEMS INCLUDING SYSTEMS WITH

INTERMITTENT IGNITION CONTROLS OR VENT DAMPERS (NO NEED FOR RELAYS FOR ISOLATING CIRCUITS)

• EMR (ENERGY MANAGEMENT RECOVERY) FOR AN EARLY START TEMPERATURE RECOVERY IN HEATING OR COOLING

• PROGRAMMABLE FAN FEATURE ON HEAT/COOL MODELS• WIDER 40-99° F TEMPERATURE RANGE.• ALSO SUITABLE FOR CENTRAL ELECTRIC HEAT SYSTEMS. NO NEED FOR A

SPECIAL THERMOSTAT MODEL

P/N.: 1F90-0511F97-051

1F90-051 SHOWN

P569

Page 6: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

442

WHITE-RODGERS WALL THERMOSTATS

DIGITAL MULTI-STORAGE COMFORT-SET THERMOSTATS

DIGITAL HEAT PUMP COMFORT-SET THERMOSTATS

• SEPARATE SET-BACK PROGRAMMING FOR FIVE DAY WEEK AND TWO DAY WEEKEND• FACTORY PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS• FOUR SEPARATE TIME AND TEMPERATURE SETTINGS PER 24 HOUR PERIOD• AUDIO/VISUAL PROGRAM PROMPTING• LCD DISPLAYS CONTINUOUS SET POINT, TIME AND ROOM TEMPERATURE AND SYSTEM

MODES.• “HOLD TEMP” BUTTON PROVIDES MANUAL OVERRIDE OF PROGRAM.• RED LED SHOWS SYSTEM IS OPERATING (lF91-1)• EASILY ACCESSIBLE TEMPERATURE BUTTONS PROVIDE TEMPORARY 2-HOUR TEMPERATURE

OVERRIDE.• BATTERY BACKUP CAPABILITY (9v DC ALKALINE TYPE).• °F/ °C DISPLAY OPTION.• INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING.• COMPRESSOR SHORT CYCLE PROTECTION. COMPRESSOR PROTECTION AS WELL FOR

EXTENDED POWER OUTAGES.• BACK-LIT DISPLAY• PROGRAMMABLE BLOWER CONTROL• COMPUTED EMR (ENERGY MANAGEMENT RECOVERY) PROGRAM• OPTIONAL AUTOMATIC OR MANUAL SYSTEM CHANGEOVER (INSTALLER ADJUSTABLE).

P/N: 1F91-071

1F91-071 SHOWNP569

• SEPARATE SET-BACK PROGRAMMING FOR FIVE DAY WEEK AND TWO DAY WEEKEND• FACTORY PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS• FOUR SEPARATE TIME AND TEMPERATURE SETTINGS PER 24 HOUR PERIOD• AUDIO/VISUAL PROGRAM PROMPTING• LCD DISPLAYS CONTINUOUS SET POINT, TIME AND ROOM TEMPERATURE AND SYSTEM

MODES.• “HOLD TEMP” BUTTON PROVIDES MANUAL OVERRIDE OF PROGRAM.• EASILY ACCESSIBLE TEMPERATURE BUTTONS PROVIDE TEMPORARY 2-HOUR TEMPERATURE

OVERRIDE.• BATTERY BACKUP CAPABILITY (9v DC ALKALINE TYPE).• °F/°C DISPLAY OPTION.• INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING.• COMPRESSOR SHORT CYCLE PROTECTION. COMPRESSOR PROTECTION AS WELL FOR

EXTENDED POWER OUTAGES.• BACK-LIT DISPLAY• PROGRAMMABLE BLOWER CONTROL• COMPUTED EMR (ENERGY MANAGEMENT RECOVERY) PROGRAM• OPTIONAL AUTOMATIC OR MANUAL SYSTEM CHANGEOVER (INSTALLER ADJUSTABLE).• FOUR LED INDICATOR LIGHTS

EMER (RED) - SYSTEM IN EMERGENCY MODEMALF (RED) - HEAT PUMP SYSTEM MALFUNCTIONINGPUMP (GREEN) - COMPRESSOR OPERATIONAUX (YELLOW) - AUXILIARY HEAT ACTIVITY

P/N: 1F92-071

1F92-071 SHOWN

P573

Page 7: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

443

WHITE-RODGERS WALL THERMOSTATS

HEATING/COOLING AND COOLING ONLY ASTRO* STATS WITH SELECTOR-SWITCHES

• DUSTPROOF SEALED MERCURY CELLS OR SNAP-ACTION CONTACTS WITH DUSTCOVER• BEIGE CASE WITH GOLD TONE DIAL• POSITIVE CONTACT SNAP-SWITCHES ON SUBBASE• BIMETAL THERMOMETER• CLEAR FACEPLATE - REMOVABLE FOR EASY CLEANING• HEATING AND COOLING ANTICIPATORS PROVIDE NARROW DIFFERENTIAL CONTROL OF

ROOM TEMPERATURE

P/N: 1D56-3101F56-3011F56-4441E56-444

1D56-301 SHOWN 1F56-444 SHOWN 1E56-444 SHOWN

P574

P574 P574 P577

ASTRO����STATS WITH SNAP ACTION SWITCH

P5781D30-316 SHOWN

• SNAP ACTION CONTACTS WITH DUST COVER• NON-SUSCEPTIBLE TO SLIGHT JARS AND VIBRATIONS• IDEAL FOR MOBILE HOME USE• HEATING AND/OR COOLING ANTICIPATORS PROVIDE A NARROW DIFFERENTIAL CONTROL

OF ROOM TEMPERATURE

P/N: 1D30-3161C30-302

P5771C30-302

Page 8: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

444

WHITE-RODGERS WALL THERMOSTATS

AUTOMATIC COMFORT-SET CLOCK THERMOSTATS• ALLOWS INSTALLATION OF SET BACK THERMOSTAT WITHOUT ADDITIONAL WIRING.• SOLID STATE QUARTZ TIMER POWERED BY STANDARD “AA:” ALKALINE BATTERY

ELIMINATES SYSTEM COMPATIBILITY PROBLEMS• BATTERY MAINTAINS CORRECT TIME IN EVENT OF POWER INTERRUPTION• COLOR-CODES, SNAP ON INDICATORS MAY BE POSITIONED TO RAISE OR LOWER

TEMPERATURE FOR ONE OR MORE PERIODS OF TIME FOR INTERVALS AS SHORT AS TWO HOURS

• EQUIPPED WITH ADJUSTABLE HEAT ANTICIPATOR FOR NARROW DIFFERENTIAL CONTROL OF ROOM TEMPERATURE. ANTICIPATOR IS FIELD REPLACEABLE

• SNAP-ON COVER HAS CLEAR, REMOVABLE FACEPLATE FOR CLEANING.

P/N: 1F72-360

1F76-357

1F72-360 SHOWN

1F76-357 SHOWN

P580

P581

P582

HEAT PUMP THERMOSTAT

BASIC MODEL1F78-144 Non-Programmable

STANDARD SERIES

1F80-261 Programmable 5/2 Day

1F86-244 Non-Programmable

P583

• MANUAL CHANGEOVER • DUAL MERCURY CELL ARRANGEMENT ON A SINGLE BI-METAL PROVIDES CONTROL

WITHOUT COMPLICATED GEAR AND LEVER ARRANGEMENTS• THERMOSTAT MOUNTS TO SUBBASE WITH POSITIVE CAPTIVE SCREWS• SUBBASE TERMINAL SCREWS SPACED AND IDENTIFIED FOR EASY INSTALLATION

P/N: 1F58-058

• SELECTABLE ENERGY MANAGEMENT RECOVERY• B & O TERMINALS• 60% LARGER DISPLAY• 4 TIME AND 4 TEMPERATURE SETTINGS (HEAT & COOL)

P4275

Page 9: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

445

FAP WALL THERMOSTATS

STANDARD WALL THERMOSTATS (ROBERTSHAW AND WHITE-RODGERS)STANDARD SERIES

THERMOSTAT

• SINGLE STAGE - FOR HEATING OR COOLING ONLY WITHOUT SUB-BASE

• CONVERTS TO HEATING/COOLING WITH SUB-BASE BELOW• SNAP ACTING SPDT SWITCH• HEAT ANTICIPATOR: .18-1.0 AMP ADJUSTABLE• COOLING ANTICIPATOR: FIXED• MOUNTS DIRECTLY ON WALL

SUB-BASE

• MANUAL CHANGEOVER• SYSTEM SWITCH: HEAT-OFF-COOL• FAN SWITCH: ON-AUTO

FOR USE ON:

P/N LOGOHH01YA092 CARRIER

CM-260 ROBERTSHAW

P/NGENERAL

USE

AUTOFAN

OPERATIONUSE ON

SB-4A-12

GAS ELECTRIC SPLIT SYSTEMS

AND SELF-CONTAINED

COOLINGONLY

ONE OR TWO TRANSFORMER

SYSTEMS

HH93YZ094

HEAT PUMP,COOLING WITH

ACCESSORY ELECTRIC HEAT

HEATINGAND

COOLING

SINGLETRANSFORMER

SYSTEMSONLY

P585

24 VOLT HEATING/COOLING THERMOSTAT AND SUB-BASE

SINGLE STAGE

THERMOSTAT

• FOR HEATING ONLY WITHOUT SUB-BASE• CONVERTS TO SINGLE STAGE HEATING AND COOLING WITH

SUB-BASE BELOW• SNAP ACTION BI-METAL SWITCH• HEATING ANTICIPATOR: .18-1.0 AMP• INCLUDES CONCEALED WALL PLATE AND TWO MOUNTING

SCREWS

SUB-BASES

• MANUAL CHANGEOVER FOR THERMOSTAT• SYSTEM SWITCH: COOL-OFF-HEAT• FAN SWITCH: ON-AUTO• COOLING ANTICIPATOR: FIXED

FOR USE ON:

P/N: HH01PD042

P/NGENERAL

USE

AUTOFAN

OPERATION

EXTRA TERMINAL

PROVIDED ONHEATING SIDE

USE ON

HH93PZ094

SPLIT SYSTEMS,SELF-CONTAINED

ANDGAS ELECTRIC

COOLINGONLY

ONE OR TWO TRANSFORMER

SYSTEMS

HH93PZ096COOLING WITH

ACCESSORY ELECTRIC HEAT

COOLINGAND

HEATING

P586

Page 10: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

446

FAP WALL THERMOSTATS

WALL THERMOSTATS (HONEYWELL)LINE VOLTAGE THERMOSTAT

THERMOSTAT P/N: T651A2028

• SNAP ACTING SPDT DUAL BI-METAL SWITCH• HEATING - CONTACTS OPEN ON TEMP. RISE• COOLING - CONTACTS CLOSE ON TEMP. RISE• FOR HEATING, COOLING AND HEAT/COOL SYSTEMS• CONTROLS FAN COILS, FANS, MOTOR STARTERS, VALVES,

CONTACTORS AND CIRCULATOR MOTORS• FIXED COOLING ANTICIPATOR• MOUNTS ON STANDARD VERTICAL OUTLET BOX• ELECTRICAL RATING (A/C AMPS)

SUB-BASE

• PROVIDES MANUAL SYSTEM SWITCHING• SWITCH POSITIONS: HEAT-OFF-COOL• MOUNTS ON STANDARD VERTICAL OUTLET BOX

WITH HONEYWELL LOGO

WITH CARRIER LOGO

P/N: Q473A2006

20V 208/240V 277VFULL LOAD 8.0 4.0 4.0LOCKED ROTOR 48.0 24.0 4.0RESISTIVE RATING: 7.2 AMPPILOT DUTY RATING: 125VA

7-DAY PROGRAMMABLE THERMOSTAT

• 2 STAGE HEAT AND 2 STAGE COOL • TIME OF DAY DISPLAY • ROOM TEMPERATURE DISPLAY • PROVIDES COMPLETE AUTOMATIC HIGH AND LOW

TEMPERATURE CONTROL • 7 DAY PROGRAMMING • 4 HEAT AND 4 COOL TEMPERATURE SELECTIONS PER DAY • AUTO-CHANGEOVER • INCLUDES SUBBASE AND BATTERIES

P/N: HH641103 WITH CARRIER LOGO

P584

P589

Page 11: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

447

MISCELLANEOUS WALL THERMOSTATS

RESIDENTIAL - HEATING - HEATING/COOLING

SUBBASES

HEAT PUMP

LOGOVENDOR &

VENDOR P/NFUNCTION

TEMPRANGE (°F)

HEAT ANTIC.AMPS

NOTES P/N

RobertshawRobertshaw

CM 65Heating-Cooling

50 - 90 0.18 to 1.0Add Subbase SB-6A-12 for switching(Magnetic Contacts)

CM-65

Bryant, Day &Night, Payne

W/RIF56-427

Heating-Cooling

50 - 90 0.15 to 1.2Includes subbase isolated “G” circuit (Mercury Switch)

HH642501

Bryant, Day &Night, Payne

W/RID56-340

Heating-Cooling

50 - 90 0.15 to 1.2Includes subbase isolated “G” circuit(Magnetic Contacts)

HH642502

VENDOR &VENDOR P/N

FANFUNCTION

SWITCH NOTES P/N

RobertshawSB-6A-12

Heating-Off-Cooling Auto-On Use with Thermostat CM-65 SB-6A-12

LOGOVENDOR &

VENDOR P/NFUNCTION

TEMPRANGE

(°F)

HEAT ANTIC.AMPS

NOTES P/N

Bryant, Day &Night, Payne

GE3AAT83Dl4Cl

Normal-EM-HeatingHeating-Auto-Cooling

50 - 900.15 to 0.70

Heat pumpAutomatic changeover

HH643503

Bryant, Day &Night, Payne

GE3AAT83D20Hl

Auto-Heating-Cooling-Off

50 - 900.15 to 0.70

Heat pumpAutomatic changeover

HH07QW002

Bryant, Day &Night, Payne

GE3AAT83D20Bl

Heating-Off-Cooling 50 - 900.15 to 0.70

Heat pumpManual changeover

HH07QW001

Bryant, Day &Night, Payne

M/HY594G-1245

Off-EM Ht-Hi-Auto-Cool

0 to 1.0.1 to 1.2

Heat pumpAutomatic changeover

HH641502

Page 12: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

448

ROOM AIR CONDITIONER THERMOSTATS

ROOM AIR CONDITIONER THERMOSTATS

*Bulb length included**Contact Rating FLA @120/240 V

***Thermostats have overtravel at each end of rotation and there is no control in overtravel area.

†Has compressor lockout feature at tend of warm rotation.

OPER.RANGE

(F)

CAP*LENGTH

(in.)

CONTACT ROT.SEEFIG.#

SHAFTLENGTH

(in.)P/N

ARR. FLA**

KNOB TYPE61-89 34 SPDT 20 1 .8 HH22UD06361-89 40 SPDT 20 8 1.1 HH22UC06461-89 18 SPDT 25 2 .9 HH22AD06161-89 18 SPDT 25 7 .6 51DV66000265-92 24 SPDT 25 3 .9 HH22QD06461-91 34 SPDT 30 4 1.0 51HK66001161-90 21 SPDT 20 9 .8 51QF660002†61-89 28 SPDT 20 10 .6 HH22LB065

LEVER ACTUATED***61-92 24 SPDT 25 5 - HH22GD06167-87 18 SPDT 25 6 - 51SW66000467-87 27 SPDT 25 5 - HH22QD067

• BULB TYPE, CROSS- AMBIENT CHARGE

• USED WITH THERMOTUBE

• 51RQ500041• ROTATION DIAGRAMS

APPLY WHEN THERMOSTAT IS VIEWED AS SHOWN IN PICTURE

P597

SHAFT SHOWN IN WARM POSITION

W

C W

C W

CW C

W

C W

C

W

C WC

W

CW

C

#1 #2 #3 #4

#5 #6 #7 #8

#9 #10

*Bulb Length included.**Contact Rating FLA @120/240 V

***Thermostats have overtravel at each end of rotation and there is no control in overtravel area.

OPER.RANGE

(F)

CAP*LENGTH

(in.)

CONTACT ROT.SEEFIG.#

SHAFTLENGTH

(in.)P/N

ARR. FLA**

KNOB TYPE25-63 36 SPDT 20 5 .6 HH22UC06759-92 18 SPST 20 1 .5 51KR68005861-83 18 SPST 20 2 .5 51KY13095661-89 18 SPST 20 11 1.9 HH22YB06361-90 18 SPDT 25 3 .6 51PC68009061-90 18 SPDT 25 4 .5 51PH12925661-90 22 SPST 20 6 .9 51EH66000361-90 24 SPST 23 4 .9 HH22GB06266-89 12 SPST 20 8 .6 HH22QB06260-85 24 SPST 25 10 .8 51NT42302007

LEVER ACTUATED***61-90 24 SPST 23 9 - HH22GB06065-91 24 SPDT 25 9 - HH22QD06665-91 36 SPST 30 9 - 51YC660007

• CAPILLARY TYPE, VAPOR CHARGE

• USED WITH THERMOTUBE

• 51RA500131• ROTATION DIAGRAMS

APPLY WHEN THERMOSTAT IS VIEWED AS SHOWN IN PICTURE

P598

SHAFT SHOWN IN WARM POSITION

W

C

#3

#6 #8

W C#1

W

C

#2W

CW

C

#4

WC

W

C#10

W

C#11

#5

WC

W

C

#9

Page 13: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

449

ROOM AIR CONDITIONER THERMOSTATS

CAC COMPONENTSBELLOWS HEATER

TEMPERATURE SWITCH... SNAP ACTION

VOLTS HEATER RATING (WATTS) P/N115 2.8 51PG098642230 2.7 51PG098517

• BELLOWS HEATERS FOR GENERAL ELECTRIC RAC THERMOSTATS

• USED ON UNITS WHERE A COLD CONTROL BOX CAUSES THERMOSTAT TO CONTROL POORLY

• 5 INCH LEADS• HEATERS MOUNT WITH 51PG098675

CLIP• LEADS TERMINATE IN.25 DOUBLE

QUICK -CONNECTS

P597

• OPENS ON TEMPERATURE RISE

• DISC TYPE

• AUTOMATIC RESET

• SPST CONTACT ARRANGEMENT

• QUICK CONNECT TERMINALS

• 125 VA PILOT DUTYP598

*ENC. - Enclosed bimetal; EX. - Exposed bimetal**Manual reset†1DPST contact arrangement.

Flush mount.

OPEN TEMP.(°F)

CLOSE TEMP.(°F)

FLA 120 VAC FLA 240 VACINSERT DEPTH

(in.)HOLE SIZE

(in.)BIMETAL P/N

40 32 13 10 3/8 1-3/16 ENC. HH17JB03250 40 23 23 3/8 15/16 ENC. HH18HA05070 60 5.8 2.9 3/16 5/8 ENC. HH18HA074

110 85 13 10 3/8 1-3/16 ENC. HH13HA210110 90 10 5 3/8 15/16 EXP. HH18HA110115 85 10 5 11/32 15/16 EXP. HH12HV115†115 90 10 5 3/8 15/16 EXP. HH18HA117120 90 10 5 3/8 15/16 EXP. HH18HA120125 90 10 5 3/8 15/16 EXP. HH18HA125130 90 10 5 3/8 15/16 ENC. HH18HA127130 100 10 5 3/8 15/16 EXP. HH18HA130140 100 10 5 3/8 15/16 EXP. HH18HA141150 110 10 5 3/8 15/16 EXP. HH18HA150150 130 10 5 3/8 15/16 EXP. HH18HA129160 105 4.4 2.2 3/8 15/16 EXP. HH12HA163**160 110 10 5 3/8 15/16 EXP. HH18HA161160 110 13 10 3/8 1-3/16 ENC. HH12HA159160 120 10 5 3/8 15/16 EXP. HH18HA160160 145 4.4 2.2 3/16 13/16 ENC. HH12HA161165 120 4.4 2.2 5/32 13/16 EXP. HH12HA120170 110 10 5 3/8 15/16 EXP. HH18HA173175 120 10 5 3/8 15/16 EXP. HH18HA176180 140 10 5 3/8 15/16 EXP. HH18HA182180 140 10 5 3/8 15/16 ENC. HH18HA194**180 160 10 5 3/8 15/16 EXP. HH18HA179185 145 10 5 3/8 15/16 EXP. HH18HA186185 145 4.4 2.2 3/16 13/16 EXP. HH12HA185190 150 10 5 3/8 15/16 EXP. HH18HA191195 155 10 5 3/8 15/16 ENC. HH18HA195**200 160 7.2 3.6 13/32 1-7/32 EXP. HH12HA199200 135 10 5 ENC. HH18HA199**215 175 10 5 25/64 15/16 ENC. HH18HA215**220 175 10 5 5/32 13/16 EXP. HH12HA225275 230 7.2 3.6 5/32 13/16 EXP. HH12HA275290 250 10 5 25/64 15/16 ENC. HH18HA291**325 280 7.2 3.6 3/16 13/16 EXP. HH12HA325350 280 10 5 25/64 15/16 ENC. HH18HA350**

Page 14: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

450

MISCELLANEOUS PARTSMISCELLANEOUS PARTSROOM AIR CONDITIONER SERVICE CORDS

ROOM AIR CONDITIONER FILTERThe 51YA680001 polyure-thane foam replacement room air conditioner filter measures 22-3/4 in. x14-1/2 in. x 1/4 in. thick. It can be trimmed to fit most RAC’s in use today. P/N: 51YA680001

FIGUREWIREGAGE

AMPS VOLTSLENGTH

(in.)P/N

E14

20 25066 52BQ400434

12 92 51SW400063

G10

30 25060 51FL401524

10 100 51YA40059312 66 52BO400444

• 1/4 IN. QUICK CONNECT TERMINALS ON POWER LEADS

• RING TERMINAL ON GROUND WIRE

• IVORY COLOR EXCEPT 51PC CORDS ARE GRAY

FIGUREWIRE

GAUGEAMPS VOLTS

LENGTH(in.)

P/N

A 14 15 125 93 51SA400353

B14

15 25066 52BQ400424

16 113 60AA400084

D12

20 12560 51FA402483

12 113 60AA400094

FIG. A FIG. B FIG. C FIG. D FIG. E FIG. F FIG. GP402

P729

Page 15: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

451

TOTALINE® THERMOSTAT GUARDSTHERMOSTAT GUARDS

• Metal: beige

• Plastic: beige or clear

• Sizes fit most thermostats

• Solid and ring bases

• Have key lock

• Virtually tamper proof

Metal

Plastic

P593

P594

Metal

Plastic

WIDTH (in.) HEIGHT (in.) DEPTH (in.) BASE STYLE P/N3-7/8 3-1/2 2-1/2 Solid Beige P269-00105-1/4 4-5/8 3 Solid Beige P269-00115-1/4 4-5/8 3-1/4 Ring Beige P269-00126-3/8 3-1/2 3 Solid Beige P269-00136-3/8 3-1/2 3-1/4 Ring Beige P269-0014

6 3-3/16 3-1/8 Ring Beige P269-00156-1/4 4-3/4 3 Solid Beige P269-00167-1/4 5-3/8 3-1/2 Solid Beige P269-00176-3/4 4-1/4 3-9/16 Ring Beige P269-0018

WIDTH (in.) HEIGTH (in.) DEPTH (in.) BASE STYLE P/N3-7/8 3-1/2 2-1/2 Solid--- Clear- P269-00013-7/8 3-1/2 2-1/2 Solid Beige P269-00025-1/4 4-5/8 3 Solid Clear

P269-00035-1/4 4-5/8 3-1/4 Ring Clear5-1/4 4-5/8 3 Solid Beige

P269-00045-1/4 4-5/8 3-1/4 Ring Beige6-3/8 3-1/2 3 Solid Clear

P269-00056-3/8 3-1/2 3-1/4 Ring Clear6-3/8 3-1/2 3 Solid Beige

P269-00066-3/8 3-1/2 3-1/4 Ring Beige8-1/4 5-3/8 3-1/2 Ring Clear P269-00078-1/4 5-3/8 3-1/2 Ring Beige P269-0008

®

Page 16: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

452

SWITCHESROCKER SWITCHES

ROTARY SWITCHES

DESCRIPTION FIGURE P/NOn-Off Action, SPST Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 125/250 V, 1/4 In. Quick Connects, Indicator Light A HR51680001

On-On Action, SPDT Contacts, 20 Amps @ 125 V/250 V, 1-1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects

B

51KX680007

On-Off-Momentary On Action, SPDT Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V 1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects

HR54ZZ001

On-Off Action, DPST Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 250 V, 1/4 In. Quick Connects

HR54AF042

On-On Action, DPDT Contacts, 10 Amps @ 125 V, 5 Amps @ 250 V,1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects

HR54ZJ001

On-Off Action, SPDT Contacts, 12 Amps @ 125 VAC, 6 Amps @ 250 VAC 3/16 In. Quick Connects

HR54ZD001

On-Off Action, SPST Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V,1/4 HP Rating @ 125/250 V, 1/4 In. Quick Connects C HR51ZA130

Lighted, On-Off Action, SPST Contacts, 16 Amps @ 125 V, 20 Amps @ 250 V, 1/4 In. Quick Connects D (125 V) -

(250 V) -HR54ZA001HR54ZA002

FIG. E FIG. F FIG. GP684

P683P685

DESCRIPTION FIGURE P/NOn-Off Action, SPST Contact, 6 Amps @ 125 V, 3 Amps @ 250 V,1/4 In. Quick Connects E HR56BZ030

On-On Action, SPDT Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V, 1/10 HP Rating @ 125 V, 1/4 HP Rating @ 250 V, .25 Shaft, Push In Connections F HR56KH277

On-On Action, SPDT Contacts, 20 Amps @ 125/250 V, 1 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, 1/4 In. Quick Connects

G

HR56KE044

Off-1 On-1 & 2 On Action, 35 Amps @ 125/250 V, 1 HP Rating @ 125 V, 2 HP Rating @250 V, .25 Shaft, Screw Connections

HR56WL001

Off-1 On-1 & 2 On-2 & 3 On Action, 20 Amps @ 125/250 V, 1-1/4 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, 1/4 In. Quick Connects

HR56ZZ010

FIG. A FIG. B FIG. C FIG. DP679

P682P680 P681

Page 17: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

453

SWITCHESPUSH BUTTON SWITCHES

TOGGLE SWITCHES

DESCRIPTION FIGURE P/NLighted, normally Off-Momentary On Action, SPST Contacts, 8.5 Amps @ 125 V,1/4 In. Quick Connects, Indicator Light A

HR54ZA020

Lighted, On-Off Action, DPST Contacts, One Pole N.O. and One Pole N.C.,1/4 In. Quick Connects

HR52ZD040

On-Off Action, SPST Contacts, 3 Amps @ 125 V, 1 Amp @ 250 V, Solder Terminals

B

41CA680147Normally Off-Momentary On Action, SPST Contacts, 3 Amps @ 125 V,1 Amp @ 250 V, Leads

HR54BV001

Normally On-Momentary Off Action, SPST Contacts, 6 Amps @ 125 V,3 Amps @ 250 V, 1/4 In. Quick Connects

HR54BV010

Normally On-Momentary Off Action, SPST Contacts, 10 Amps @ 125/250 V,Screw Connections C HR54KX030

On-Off Action, TPST Contacts, 10 Amps @ 125/250 V, Screw Connections HR54KY030On-Off Action, DPST Contacts, 16 Amps @ 125 V, 8 Amps @ 250 V,Screw Connections D HR54BC040

On-Off Action, SPST Contacts, 20 Amps @ 125 V, 10 Amps @ 250 V,3/4 HP Rating @ 125 V/250 V, 1/4 In. Quick Connects (Door Switch) E HR54ZA003

FIG. A FIG. B FIG. C FIG. D FIG. E

P686

P689P687 P688

P690

# (M) stands for momentary.*Rated 30A, 2HP @ 480V.

FIGURE ACTION #CONTACT

ARRANGE- MENT

CONTACT RATINGTERMINAL

CONN.P/NAMPS HP

125V 250V 125V 250V

F

ON-OFF SPST 15 10 1/2 3/4 1/4″ Q.C. HR53ZA035ON-ON SPDT 6 3 1/4 1/4 LEADS HR53ZE050ON-ON SPDT 6 3 1/4 1/4 1/4″ Q.C. HR53AE070ON-ON SPDT 15 10 3/4 3/4 SCREW HR53BE019ON-ON SPDT 15 15 1/2 1 SOLDER HR53ME040

ON-OFF-ON SPDT 15 7.5 1/2 - SCREW HR53VR026ON-(M)ON SPDT 15 10 3/4 3/4 3/16″ Q.C. HR53ZE010

(M)ON-OFF-(M)ON SPDT 6 3 - - 1/4″ Q.C. HR53ED010ON-OFF DPST 15 10 3/4 3/4 SCREW HR53SF015ON-ON DPDT 15 15 1/2 1 SOLDER HR53MJ010ON-ON DPDT 15 10 3/4 3/4 1/4″ Q.C. HR53VK121

ON-OFF-ON DPDT 15 10 3/4 3/4 1/4″ Q.C. HR53VK120ON-OFF-ON DPDT 20 MA - - - 1/4″ Q.C. HR53ZK001

H ON-OFF DPST - x5 - 2 SCREW HR53KA040*

P691FIG. F

P692FIG. H

Page 18: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

454

SWITCHESMICRO SWITCHES

*Miniature type.**Used in H-W S952 step controller.†Used in H-W S984 step controller.

FIG.OPER. FORCE

(OZ.)

RELEASE FORCE (OZ.)

CON- TACT ARR.

ELECTRICAL RATING

P/N

A 6-14 4 SPDT10A @

125/250VHR54MA010 *

B 8 2 SPDT5A @ 24V

7A 120/240VHR54MA020 *

C 2.5 .5 SPDT

30A @ 125-460V

HR64TE0403/4 HP @

120V1-1/2 HP @

240V

D 5 1 SPDT10A @ 125V

HR64TE0101 HP @ 125V **2 HP @ 250V

E 6 1 SPDT15A @

125-460VHR64TE038

F 35 8 SPDT 570 VA HR64TE020

FIG. A FIG. B

FIG. C FIG. D

FIG. EFIG. F

P694

P695

P696

P698

P699

P697

MISCELLANEOUS SWITCHES

INDICATOR LIGHTS

• FURNACE DOOR INTERLOCK SWITCH

• SPST-NORMALLY OPEN• 16 AMPS @ 125/250 V

• 10 AMPS @ 125/250 V

P/N: 58SGB4310407

P/N: HR54ZA101P701

P700

• SLIDE ACTION ON-OFF(SPST) SWITCH

• RATED 6 AMPS @ 125 V3 AMPS @ 125V

• 6 IN. LEADS

P/N: 51TJ660012

FIG. VOLTAGELENS

COLORHOLE

SIZE (IN.)TERM.CONN.

P/N

G

24 RED 1/2 3/16″ Q.C HY19AZ02524 AMBER 1/2 3/16″ Q.C HY19AZ024120 RED 1/2 3/16″ Q.C HY19AZ002120 AMBER 1/2 3/16″ Q.C HY19AZ004240 RED 1/2 3/16″ Q.C HY19AZ007240 AMBER 1/2 3/16″ Q.C HY19AZ009

H115 RED 1 1/4″ Q.C HY19UC018230 RED 1 1/4″ Q.C HY19UC014

I24 RED 1/2 3/16″ Q.C 41CA68014324 GREEN 1/2 3/16″ Q.C 41CA68014424 AMBER 1/2 3/16″ Q.C 41CA680145

J 12 WHITE, 1/2 LEADS 31TC113750

FIG. GFIG. H

FIG. I

FIG. J

P702

P703

P704P705

Page 19: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

455

TEMPERATURE ACTUATED SWITCHESTEMPERATURE SWITCH... SNAP ACTION

TEMPERATURE SWITCH... SNAP ACTION, FLUSH MOUNT

• SPDT SWITCHING• 1-9/16 IN. MOUNTING HOLE

SPACING• AUTO RESET

*FLA 14 @ 120 VAC and 240 VAC.**Enclosed Disk.

OPEN TEMP (°F) CLOSE TEMP (°F) P/N

100 85 HH19ZA100120 90 HH19ZA120125 90 HH19ZA125130 95 HH19ZA130135 95 HH19ZA135140 100 HH19ZA140145 105 HH19ZA145150 110 HH19ZA150155 105 HH19ZA156155 115 HH19ZA155165 125 HH19ZA165170 130 HH19ZA170175 135 HH19ZA175175 - HH19ZH175*180 130 HH19ZA181180 140 HH19ZA180190 150 HH19ZA190195 155 HH19ZA195195 - HH19ZH195*200 130 HH19ZA201220 - HH19ZA220165 150 HH680302195 155 HH680305205 165 HH680306210 170 HH680307**200 160 HH680311330 250 HH680313**340 300 HH680315

TEMP (°F) AMP.RTG.@ 240 V

INSERTDEPTH

(in.)

HOLESIZE(in.)

P/N1-3OPEN

1-3CLOSE FLA RES.

61 75 2.9 5 3/8 1-1/16 HH18HD07580 65 2.9 5 7/16 1-1/16 HH18HD07095 87 2.9 5 7/16 1-1/16 HH18HD117

105 97 2.9 5 7/16 1-1/16 HH18HD105118 110 2.9 5 7/16 1-1/16 HH18HD118110 90 5 25 3/8 15/16 HH18HV110120 90 5 25 3/8 15/16 HH18HV120125 95 5 25 3/8 15/16 HH18HV125135 110 5 25 3/8 15/16 HH18HV135145 115 5 25 3/8 15/16 HH18HV145155 125 5 25 3/8 15/16 HH18HV155160 130 5 25 3/8 15/16 HH18HV160170 130 3.6 25 3/8 1-7/32 HH12HC171170 140 5 25 3/8 15/16 HH18HV170180 140 2.9 25 5/32 13/16 HH12JC180185 155 5 25 3/8 15/16 HH18HV185205 175 5 25 3/8 15/16 HH18HV205230 190 3.6 25 5/32 13/16 HH12HC230

• SPST• INSERT DEPTH: 3/8 IN.• OPENS ON TEMPERATURE

RISE• FLA: 10 @ 120 VAC

5 @ 230 VAC• HOLE SIZE: 15/16 IN.• HEIGHT MOUNTED:

11/16 IN. P613

P612

• CLOSES ON TEMPERATURE RISE

• SPST. CONTACT ARRANGEMENT

• DISC TYPE• AUTOMATIC RESET

• SPST. CONTACT ARRANGEMENT

• SWITCH RATING: 25 AMPS NON-INDUCTIVE, 25 VA PILOT DUTY @ 120-277 VAC

*Flush mount over hole specified.**Flush mount on surface.

TEMP (°F) FLA120VAC

FLA240VAC

INSERTDEPTH

(in.)

HOLESIZE(in.)

P/NOPEN CLOSE

95 125 13 10 * 1-1/32 HH12HC009*110 135 1 1 ** - HH17JA110**116 175 10 5 3/8 15/16 HH19ZB175190 210 7.2 3.6 7/16 1-7/32 HH12HB210

*SPDT contact arrangement.

TEMP (°F)RESET

CAPIL. LENGTH

(in.)

ELEC.CONN.

P/NOPEN CLOSE

160 140 AUTO. 24 QC HH22HA141190 150 AUTO. 48 QC HH22HA191225 185 AUTO. 48 QC HH22HA225225 185 MAN. 30 QC HH22HA231*240 200 AUTO. 66 SCREW HH22HA240

285 245 AUTO. 96 QC HH22HA284

P613P615

Page 20: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

456

TEMPERATURE ACTUATED SWITCHESTEMPERATURE SWITCH ... FLUSH MOUNT

TEMPERATURE SWITCH ... TUBE MOUNTED

• FLUSH SWITCH SURFACE

• SNAP ACTION

• SEALED CONTACTS

• WITH LEADS

• FLUSH SWITCH SURFACE

• SNAP ACTION

• EXPOSED BIMETAL DISC

*Non-inductive rating.**Clip mounted.

***Contacts rated for electromechanical & electronic defrost control.†Contacts make on temperature rise.

TEMP (°F)CONTACT RTG.

(FLA) @CON-TACTARR

LEADLENGTH

(in.)P/N

OPEN CLOSE 120 V 240 V

40 52 *** *** SPST 36 HH18HB04045 35 25* 25* SPST 20 HH22HB07855 65 10 5 SPST 60 HH22HB075†60 70 10 5 SPST 60 HH22HB076†

65 28 6 3.6 SPST 48 HH18JA06670 80 10 5 SPST 60 HH22HB077†80 65 5.8 2.9 SPST 45 HH18HA080S90 120 6 3.6 SPST 48 HH18JB086**†85 65 5.8 2.9 SPDT 27 HH18HC071

105 43 6 3.6 SPST 36 HH18JA105115 100 *** *** SPST 36 HH18HA116278 178 13 10 SPST 30 HH18HB278290 210 25* 25* SPST 72 HH18HA210

†Contacts make on temperature rise.

TEMP (°F)CONTACT RTG.

(FLA) @CON-TACTARR.

ELEC.CONN.

P/NOPEN CLOSE 120 V 240 V

45 35 10 5 SPST QC HH22HB07847 57 10 5 SPST QC HH18HB052†

130 100 - 35 SPST SCREW HH18HA132140 110 - 35 SPST SCREW HHI8HA139150 110 10 5 SPST QC HHI8HA149

150 110 - 35 SPST SCREW HH18HA152155 110 - 35 SPST SCREW HH18HA155175 120 - 35 SPST SCREW HH18HA178190 140 - 35 SPST SCREW HH18HA192140 125 - - SPST HH680101

170 130 - - SPST HH680102160 145 - - SPST HH680103190 150 - - SPST HH680104

P616P618

*Clip mounted.**Contacts rated for electromechanical & electronic defrost control.†Contacts make on temperature rise.‡Used on aluminum tube.

TUBEDIA.(in.)

TEMP (°F)CONTACTRTG. (FLA) CON-

TACTARR.

LEADLENGTH

(in.)P/N

@120 V

@240 V

OR CL.

5/8 5 45 125VA 125VA SPST QC HH18JA005t†5/8 28 48 13 10 SPST 43 HH18HA028†5/8 65 35 5.8 2.9 SPST 48 HH18HA0595/8 65 45 5.8 2.9 SPST 36 HH18HA0695/8 85 65 5.8 2.9 SPDT 63 HH19HC263*5/8 85 65 5.8 2.9 SPDT 18 HH18HA0855/8 1265 1651 13 10 SPST 36 HH18HA265

TUBE DIA.(in.)

TEMP (°F))CONTACT RTG. (FLA) CON-

TACTARR.

LEADLENGTH

(in.)P/N

@120 V

@240 V

OP. CL.

3/8 25 53 5.8 2.9 SPDT 36 HH18HC025†3/8 30 45 5.8 2.9 SPST 48 HH18HB0303/8 65 35 13 10 SPST 48 HH18HA0363/8 80 27 * * * * SPST 95 HH18HA0943/8 80 27 * * * * SPST 95 HH18HA098‡

3/8 80 40 * * * * SPST 48 HH18HH0913/8 85 65 5.8 2.9 SPST 45 HH18HA0863/8 90 80 5.8 2.9 SPST 35 HH18HA0803/8 100 135 5.8 2.9 SPST 24 HH18HA100†3/8 140 125 5.8 2.9 SPST 24 HH18HA142

3/8 50 27 * * * * SPST QC HH18HA0811/2 5 45 125VA 125VA SPST QC HH18JA004†1/2 25 53 5.8 2.9 SPDT 102 HH18HC102†1/2 60 40 5.8 2.9 SPST 75 HH18HA0471/2 61 35 6 3.6 SPST 36 HH18JA062

1/2 65 28 6 3.6 SPST 48 HH18JA0671/2 65 35 13 10 SPST 36 HH18HA0351/2 65 45 5.8 2.9 SPDT 36 HH18HC0651/2 80 27 * * * * SPST 55 HH18HA095‡1/2 85 65 1.5 1.5 SPST 19 HH18HA054

• TUBE MOUNTED

• SNAP ACTION

• SEALED CONTACTSP617

Page 21: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

457

TEMPERATURE ACTUATED SWITCHESNON-ADJUSTABLE TEMPERATURE ACTUATED SWITCHES

ADJUSTABLE REMOTE BULB THERMOSTATS

• FIXED DIFFERENTIAL

• VAPOR FILLED

• CONTACTS RATED 20 FLA @ 240 VOLTS

• REMOTE BULB NON-ADJUSTABLE THERMOSTAT

• SPST CONTACTS OPEN ON TEMPERATURE RISE

CONTACTS(°F)

CONTACT RTG.(FLA) @

CAPIL.LENGTH

(ft)

BULBSIZE(in.)

P/NOPEN CLOSE 120V 240V

275 200 16 8 3 3/8 x 3 HH22YC275

SPDT SWITCHING

CONTACTS (°F)DIFFER-

ENTIAL (°F )

CAPIL. LENGTH

(in.)P/N

OPEN CLOSE

26 55 29 36 50BB66000135 39 4 35 HH22UA035

72.5 67.5 5 18 HH22UA070

TEMP.SETTINGS (°F) DIFFER-ENTIAL

(°F)

CAPIL.LENGTH

(in.)P/N

2-1 MAKE 2-3 MAKE

15 35 20 42 HH22UC03420 45 25 27 HH22UC02036 42 6 24 HH22UC03840 44 4 27 HH22UC04087 91 4 18 HH22UC090

• DPST SWITCHING ACTION WITH ONE SIDE COMMON

• 24 VOLT MAXIMUM AC ROSS TERMINALS

• Tl CONTACTSCLOSE @ 50 ° FT2 CONTACTSCLOSE @ 54 ° F

P/N: HH21PD055

1

2

3

P339-2

P623

P619

*Opens on temperature rise.**Close on temperature rise.

FIGURECAPILLARYLENGTH (ft)

BULB SIZE(in.)

RANGE(°F)

DIFFER-ENTIAL (°F)

CONTACTARR.

CONTACT RATING. (FLA) P/N

@ 120 V @ 240 VB 6 3/8 x 5.5 -20 to 70 6 SPST* - 25 HH22YA070C 10 3/8 x 5 -10 to 55 5 SPST* - 30 HH22VA040D 4 3/8 x 3.7 0 to 50 6 SPST* - 6 HH22PA050G 4 3/8 x 7.2 50 to 70 2 SPDT 20 20 HH22UA078G 3 3/8 x 7 58 to 85 3 SPDT 20 20 HH22UZ101E 2 3/8 x 5 60 to 96 3 SPDT - 20 50BQ580-07

FIG. B FIG. C FIG. D FIG. F

P621P627

P626P624P622

FIG. G

Page 22: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

458

TEMPERATURE ACTUATED SWITCHESADJUSTABLE REMOTE BULB THERMOSTATS

• STAGED REMOTE BULB THERMOSTATS• 2, 3 AND 4 -SPDT TYPES AVAILABLE • 140° F MAX. BULB TEMPERATURE• 15 FT CAPILLARY

• TWO STAGE REMOTE BULB THERMOSTATS

• TWO SPST SWITCHES OPEN ON A DROP IN TEMPERATURE

• 7-1/2 FT CAPILLARY• 160° F MAX. BULB TEMPERATURE• CONTACT RATING: 8A @ 120/240 V

• SINGLE STAGE REMOTE BULB THERMOSTATS

• SCREWDRIVER ADJUSTABLE FOR LIMITED ACCESS APPLICATIONS

FIG. A FIG. B FIG. C

*Closes on temperature drop.**See contact arrangement diagram by photo, Figure C.

FIGURERANGE

(°F)

SWITCHDIFFERENTIAL

(°F)

INTERSTAGEDIFFERENTIAL

(°F)

CONTACTARR.

CONTACT RATING.(FLA) @ - BULB SIZE

(in.)

CAPIL.LENGTH

(in.)P/N

@ 120 V @ 240 V

A20 to 8010 to 8010 to 80

3.5 6 2-SPDT 16 8 3/8 x 5.6 - HH24CZ0203 3.5 3-SPDT 10 5 3/8 x 4 - HH24CZ0213 2.5 4-SPDT 10 5 3/8 x 4 - HH24CZ022

B 55 to 105 5 13 - - - 1/2 x 3 - HH29AA080

C-15 to 4525 to 6135 to 62

8 - SPST - 5 - 36 HH22QA040*4 - SPDT - 20 - 30 HH22UC063**4 - SPDT - 20 - 33 HH22UC062*

1

2

3

P629 P630P628

Page 23: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

459

TEMPERATURE ACTUATED SWITCHESREMOTE BULB THERMOSTATS

• ACCURATELY REGULATES TEMP. OF AIR OR LIQUIDS IN DUCTS, PIPES OR TANKS WHERE CONTROLLER MUST BE PLACED OUTSIDE THE SENSING AREA

• HH22AN100 AND HH22AL090 ARE TWO STEP CONTROLS. HH22AN100 HAS AN ADJUSTABLE INTERSTAGE DIFFERENTIAL OF 3 TO 10 DEGREES. HH22AL090 HAS A FIXED INTERSTAGE DIFFERENTIAL OF 2-1/2 DEGREES.

• REMOTE BULB TEMPERATURE CONTROLS WITH SPST CONTACTS THAT CLOSE ON TEMPERATURE RISE

• HH22PB030 AND HH22PB036 ARE MANUAL RESET DEVICES

• REMOTE BULB TEMPERATURE CONTROL

• BULB WELL IS SUPPLIED WITH CONTROL

• MAY BE MOUNTED IN ANY POSITION

FIG. FFIG. EFIG. D

*HH22AL090, HH22AC090 do not have an enclosure.

FIGURERANGE

( °F)DIFFER-

ENTIAL ( °F)CONTACT

ARR.CONTACT RATING. (FLA) CAPILLARY

LENGTH (ft)BULB SIZE

(in.)MAX.

TEMP ( °F)P/N

@120 V @240 V

D

-30 to 90 Adj. 5 to 40 SPDT 7.4 3.7 8 3/8 x 5.0 155 HH22PC0200 to 100 Adj. 3 to 10 SPDT 8 5.1 20 1/2 x 4.5 125 HH22AG1060 to 100 Non-Adj.3 2-SPDT 8 5.1 20 1/2 x 4.5 125 HH22AN10055 to 90 Non-Adj. 2 SPDT 3.2 1.6 5 5/16 x 11.7 135 HH22AC090*55 to 90 Non-Adj. 2 2-SPDT 8 5.1 5 1/2 x 11.7 135 HH22AL090*

E-20 to 50 - SPST 7.4 3.7 10 3/8 x 5.7 120 HH22PB03020 to 75 Adj.3 to 20 SPST 13 6.5 8 3/8 x 7.2 120 HH22PB03233 to 55 - SPST 7.4 3.7 20 5/16 x 11 120 HH22PB036

F 50 to 200 Adj. 6 to 24 SPDT 16 8 20 3/8 x 4 290 HH680-608

P631 P632P633

Page 24: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

460

TEMPERATURE ACTUATED SWITCHESREMOTE BULB PROPORTIONAL TEMPERATURE CONTROLLER

CONTROL BULB

• PROVIDES CONTROL OF LOW VOLTAGE VALVE OR DAMPER MOTORS

• USED IN 24 VOLT CIRCUIT• AMBIENT COMPENSATED• 135 OHM POTENTIOMETER• HONEYWELL TYPE T991A

• PROVIDES CONTROL OF LOW VOLTAGE VALVE OR DAMPER MOTORS

• USED IN 24 VOLT CIRCUIT• AMBIENT COMPENSATED• 135 OHM POTENTIOMETER• HONEYWELL TYPE T915,

PENN TYPE A80

FIG. A FIG. B

*Control has 76 inch sensing element.

FIGURESET POINT ADJ.

RANGE ( °F)THROTTLINGRANGE (°F)

MAX.BULBTEMP ( °F)

CAPILLARYLENGTH (ft)

SIZE OF BULB(in.)

P/N

A0 to 100 3 to 30 125 20 1/2 x 4 HH23AG0450 to 100 3 to 30 125 9.6 1/2 x 76 HH22AG103*

B10 to 90 7 to 38 130 11 11/16 x 7 HH23AG03015 to 90 7 to 38 200 20 1/2 x 4 HH23AG085

P631

P635

• CONTROL BULB WELLS FOR USE WITH TEMPERATURE CONTROLLERS

• BUSHING INCLUDED

FOR BULBDIA. (in.)

DIMENSIONS (in.) THREADSIZE NPT

P/NA B C D

5/16 13.0 11.5 1.2 .4 1/2-14 HL79PZ0013/8 6.3 5.0 .7 .4 1/2-14 30HH4061023/8 7.6 5.8 1.4 .4 1/2-14 HL79ZZ0021/2 8.7 4.2 3.7 .7 1/2-14 HL79MZ0011/2 8.7 4.2 3.7 .7 3/4-14 HL79MZ0051/2 5.7 4.2 .7 .7 1/2-14 HL79MZ007

A

BCD

Page 25: 24 VOLT HEATING/COOLING THERMOSTAT ... - …dms.hvacpartners.com/docs/1006/Public/00/TSTATS-MISC-ACCYS... · 24 volt heating/cooling thermostat and sub- bases ... • heat anticipator

461

TEMPERATURE ACTUATED SWITCHESAQUASTAT CONTROLLERS

SWITCHING RELAYS

P4320

P/N P672-L4006

• TOTALLY ENCLOSED MICRO SWITCH SNAP-ACTING SWITCHES OPERATE ON TEMPERATURE RISE TO SET POINT.

• VISIBLE CONTROL POINT SCALE AND EXTERNAL ADJUSTMENT SCREW PERMIT EASY SETTING.

• HORIZONTAL OR VERTICAL INSERTION AND DIRECT OR WELL IMMERSION OF SENSING ELEMENT.

P/N P672-L6006C

• OPERATE IN RESPONSE TO TEMPERATURE CHANGES IN HYDRONIC HEATING SYSTEMS.

• PROVIDES SPDT SWITCHING FOR THREE-WIRE APPLICATIONS.

• COMBINES CIRCULATOR CONTROL WITH HIGH AND LOW LIMITS.

• HORIZONTAL OR VERTICAL SURFACE MOUNTING.

• VISIBLE CONTROL POINT SCALE AND EXTERNAL ADJUSTMENT SCREW PERMIT EASY SETTING.

P4321

P/N P672-L7124U UNIVERSAL OIL ELECTRONIC AQUASTAT CON-TROLLER

• PROVIDES ELECTRONIC TEMPERATURE SENSING IN A UL LIMIT-RATED CONTROL WITH A SINGLE SENSING PROBE.

• CONTROLS CIRCULATOR, OIL BURNER, AND BOILER TEMPERATURE.• REPLACES THE L8124A, L8124C, L8148A CONTROLLERS.• THE L7124U HAS A CASE THAT CAN BE CONVERTED FOR EITHER

HORIZONTAL OR VERTICAL MOUNTING.

PART NUMBERHONEYWELL

PART NUMBERP672-L4006A L4006A1009P672-L4006B L4006B1007P672-L6006C L6006C1018P672-L7124U L7124U1003

P4325

P/N P673-RA889A SWITCHING RELAY (HYDRONIC)

• HIGH LOAD SWITCHING RELAY.• TROUBLESHOOTING LED.• REPLACEABLE TRANSFORMER FUSE.• LONG LIFE DC RELAY DRIVE CONTROL

TECHNOLOGY.• RELAY FOR USE WITH EXTERNAL 24 VAC

OR 24 VDC SUPPLY, WITH LINE-VOLTAGE CONTROL, OR WITH INTERNAL 24-V TRANSFORMER SUPPLY.

P/N P673-R8845A UNIVERSAL SWITCH-ING RELAY (HYDRONIC)

• REPLACEABLE, SOCKETED RELAY.• TWO TROUBLESHOOTING LED’S.• PUSH-TO-TEST BUTTON.• REPLACEABLE TRANSFORMER FUSE.• LOW VOLTAGE CONTACTS FOR POWERPILE

APPLICATIONS.• RELAYS CAN BE USED WITH EXTERNAL

24-VAC OR 24-VDC SUPPLY, LINE-VOLTAGE CONTROL, OR WITH INTERNAL 24-V TRANSFORMER.

PART NUMBERHONEYWELL

PART NUMBERP673-RA889A RA889A1001P673-R8845A R8845U1003