12
Presented at Seminar and Site Visits 26-28 August, 2010 Water Pumping Windmills | Robert Trunz Auroville Green Practices Seminar 2010 1 of 27 Water Pumping Windmills Robert Trunz AUREKA

25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Presented at

Seminar and Site Visits26-28 August, 2010

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 1 of 27

Water Pumping Windmills

RobertTrunz AUREKA

Page 2: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 2 of 27

• Windpumps are wind driven machines for pumping water.

• Total independence from the Electricity Board

• No electricity bills

• No expenditure for diesel

• Environmentally friendly

Why Windmills?

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 3 of 27

• Cost competitive compared to diesel and solar.

• Windpumps are the most economic method of pumpingwater in rural areas where the average wind speed isgreater than about 3 m/s, and no grid power is available.

• Windpumps have a long life potential, typically 20 yearsfor a well-made and well-maintained machine.

Why Windmills?

Page 3: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 4 of 27

Sta

tic

wate

r

lev

el

Ov

er h

ead

tan

k

max

10

0m

max. 2000m

Wind velocity

average 3-5 m/s

9 -

23m

Well casing

Delivery pipe

Pump rod

Filter

Draw

down

max.

Pump

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 5 of 27

Windspeed range applicable for windpumps

17-20Breaks twigs off trees, walking difficultGale814-17Whole trees move, walking slightly impededNear gale711-14Large branches move, wires whistleStrong breeze69-11Small trees in leaf swayFresh breeze56-8Raises dust & paper, small branches moveModerate44-5Leaves, small twigs & flags in motionGentle breeze32-3Wind felt on face, leaves rustleLight breeze21Direction shown by smoke, but not vaneLight air1

Windspeed range applicable for electricity generation

0Smoke rises verticallyCalm0

Speed range(m/s)DefinitionNameForce

The Beaufort Scale

Page 4: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 6 of 27

Matching valve

The AV55 windpums incorporate anew rage of high performancepiston pumps. These pumps havean advanced technological featurecalled the matching valve thatincreases the overall efficiency ofthe windpump by 50% compared toconventional windpumps.

Advantages

• Simple design

• Requiring no extramaintenance

• Low cut-in windspeed

• Improved overall efficiencyCp� over a wider range ofwindspeed

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 7 of 27

Wind Conventional drive Matching valve with

km/h 140 mm counterweight in rotor 227 mm

Water output Increase in water output

l/h l/h %

3.5 0 179 -

7 20 560 -

10 512 863 59

13 1089 1581 45

16 1541 2323 51

19 2034 2982 46

Increase in water outputMatching valve compared with conventional drive

Page 5: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 8 of 27

Vertical Installation Tilt-up Installationof AV%% windmill tower

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 9 of 27

• The windmill can be used forpumping water from deepborewells, max. 100m depth withthe AV55 and 70 m depth with theAV45 - as well as for low lift highvolume output from shallow wells.

• For pumping underground orsurface water into a tank orreservoir which is located higherthan the windmill head

• For pumping underground waterinto a tank which is not as high asthe windmill head.

BA

max

. 1

00

m

max. 2000m

Range applications

Page 6: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 10 of 27

AV55 Output performance at 4 m/s

windspeed

0

1000

2000

3000

4000

5000

6000

7000

20 30 40 50 60 80 100

120

140

160

200

240

280

Pumping head in ft.

Wa

ter

ou

tpu

t l/

h

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 11 of 27

AV55 Output performance at 5 m/s

windspeed

0

1000

2000

3000

4000

5000

6000

7000

8000

20 30 40 50 60 80 100

120

140

160

200

240

280

Pumping head in ft.

Wa

ter

ou

tpu

t l/

h

Page 7: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 12 of 27

Windpump maintenance A comprehensive Maintenance Manual is provided with each

windpump

1.Windmill and tower

• Minimal maintenance required• Greasing of all bearings (two times a year)• Checking for any loose bolts and nuts (two times a year)

Cost per year : Rs. 500.00

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 13 of 27

2. Maintenance of pump, pump rods and delivery pipe

Depends on a number of factorsQuality or water is crucial (Sand in the water of saline water)

Average cost per year varies from Rs.3000 – Rs.5000.

Windpump maintenance

Page 8: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 14 of 27

Pump

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 15 of 27

Matching valve

Piston Foot Valve

Page 9: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 16 of 27

From a government point of view:

• windpumping is a good option, provided that large windpumps areused, second generation windpumps can compete with electricpumps in areas with an average windspeed of 4 m/sec, or above.

From a user’s point of view:

• Second generations windpumps can compete with electric pumpsif windpumps are subsidized.

The conclusion for the present situation is that in fact noalternative pumping system is competitive with electric pumping aslong as electricity is given for free.

Conclusions:Comparing the ALLC of the system

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 17 of 27

Windpump Market Study Halcrow Gilbert Associates Ltd.

0.160.31277V = 4 m/sec

0.380.75116V = 3 m/sec.

1st gen. Yellow tail copy rotor Ø 3 m

0.050.101028V = 4 m/sec

0.120.27433V = 3 m/sec.

2nd gen. Aureka, rotor Ø 5.5 m

Windpump

0.360.79150PV

0.170.1710005 hours pumping

Diesel

0.030.0821608 hours pumping

0.060.1110804 hours pumping

0.120.175402 hours pumping/day

Electric

Micro –Econ AlccUC$ cts/m4

Macro – EconAlcc US$cts/m4

Water output xhead (m4)

Pumping Technology

Table 4.6 Cost of Alternative Pumping Methods

Page 10: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 18 of 27

An Economic Comparison

Before this farmer purchased the AV55 windpump, heused a compressor pump. The site has no access toelectricity and as the ground water table was to deepfor a jet-pump, he had to use a compressor pump.

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 19 of 27

Diesel Compressor Pump:Engine Field Marshal : 10 HPCompressor : 7.5 HPOutput : 2500 liter/hDiesel consumption : 1 liter/hDiesel price 1993 : Rs.15.00/literRunning time 6 months/year : 30 h / week

3 months/year : 20 h / week3 months/year : 10 h / week

Cost of diesel compressorpump complete 1993 : Rs. 25,000/-Water output per year : 29,25,000 literDiesel cost per year : Rs. 17,550/-

Page 11: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 20 of 27

Diesel Pump AV55 Windpump

Output per year 29.25 lakh liter 36.50 lakh liter

Diesel cost/year Rs.17,550 -

Capital Investment Rs.25,000 Rs.86,240

If you calculate how much money the user would have to spend on diesel topump 36.5 lakh liters, which is the yearly output of the windmill, you will get afigure of Rs. 21,900 .

So in less then 5 years his windmill is paid off.

Water Pumping Windmills | Robert Trunz��� Auroville Green Practices Seminar 2010 21 of 27

Contact:

[email protected]

www.aureka.com

0413-2622278

Water Pumping Windmills

RobertTrunz AUREKA

Page 12: 25 energy Robi v9 - Research...2nd gen. Aureka, rotor Ø 5.5 m Windpump PV 150 0.79 0.36 5 hours pumping 1000 0.17 0.17 Diesel 8 hours pumping 2160 0.08 0.03 4 hours pumping 1080 0.11

green.aurovilleportal.org