The 2H34 Series relay is a frequency monitoringrelay with four stages of adjustable frequencypick up & drop out points.

Each frequency set point can be set for under or

over frequency operation & has an independenttime delay driving an output relay.

An undervoltage lockout is used to disable thefour frequency outputs when the voltage fallsbelow a preset level.

2H34Four Stage Frequency Relay

Frequency Stages

Page 4: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 4/26

Inputs: Single pole 63.5 or 110V ACSetting stages: 4 independent stages

Operating range: 40 to 60 HzSetting range: 41 to 59Hz in 0.05Hz stepsMeasurement resolution: 0.01Hz at 50Hz

Accuracy: +/-0.03Hz (70 to 121V) at 50HzHysterisis: 0.05 to 0.5Hz in 0.05Hz stepsOver frequency function: PU at set point

DO at set point – hysterisis +/-0.03HzUnder frequency function: PU at set point

DO at set point + hysterisis +/-0.03Hz

2H34Frequency Set Points

Page 5: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 5/26

The 2H34 allows for a separate time range for each of the

four frequency stage set points.

Setting range: 0.1 to 100s in 0.05s steps.Minimum operate time: 0.1s typicalTiming error: <20ms + 0.1% of time delay setting

Frequency ElementTime Delay Setting

Page 6: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 6/26

Each setting stage can also have a rate of change of frequencythreshold, df/dt, established.

Each dF/dt stage has an independent time delay but drives thesame output relay as the frequency stage.

Two logic options are available to control how the output contactresponds to the frequency and dF/dt pick up as follows:

OR either frequency of dF/dt will trigger thelogic stage output contact.

AND both the frequency and dF/dt must pickLogic up to activate the stage output relay.

2H34Rate of Change Of Frequency

Page 7: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 7/26

Page 8: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 8/26

2H34dF/dt Sampling Engines

To allow dF/dt setting flexibility while

remaining within the constraints described inTable 1, two dF/dt sampling engines (A & B)are provided:

dF/dt activation: Set to ON or OFFSample time A: 2 to 5 cycles in 1 cycle stepsdF/dt rejection A: 2 to 18Hz/s in 0.1Hz/s stepsSample time B: 2 to 5 cycles in 1 cycle stepsdF/dt rejection B: 0.2 to 18Hz/s in 0.1Hz/s steps

Page 9: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 9/26

2H34dF/dt Set Points

Four independent dF/dt elements are provided. When this

function is activated the dF/dt pick up is used to initiate anindependent dF/dt timer.

Setting stages: 4 independent stages

Setting range: 0.13 to 9.0Hz/s in 0.1Hz/s stepsdF/dt function: PU at set point

DO at set point – hysterisis

dF/dt engine: Select dF/dt sampling engine A or B

Page 10: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 10/26

The 2H34 allows for a separate time range for each of thefour dF/dt stage set points:

Setting range: 0.00 to 100s in 0.02s steps.Timing error: <20ms + 0.1% of the time delay setting

2H34dF/dt Time Delay Setting

Page 11: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 11/26

2H34dF/dt Setting Criteria

Sample time(Cycles) 2 3 4 5

Maximum setting(Hz/s) 9 7 6 5

Minimum setting(Hz/s) 0.70 0.50 0.20 0.13

Minimum timedelay setting 40ms 60ms 80ms 100ms

dF/dt Measurementtime 100ms 160ms 200ms 240ms

Hysterisis(Hz/s) 0.24 0.12 0.07 0.05

Accuracy at 50Hz(Hz/s) +/-0.2 +/-0.1 +/-0.07 +/-0.05

Page 12: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 12/26

The 2H34 Series relay also provides a number of independent voltage stages:

An undervoltage lockout is available to disable the four frequency outputs when the voltage falls below a presetlevel;

An undervoltage alarm stage with independent outputcontact;

An over voltage alarm stage with independent outputcontact.

2H34Voltage Stages

Voltage Alarm / Lockout Stages

Page 13: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 13/26

Summary of Output Stages

2H34Four Stage Frequency Relay

Page 14: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 14/26

Front Panel Settings & Indicators

SET page

DATA page

Diagnostics page4 Stage trip status LED’sFlash when timing, solid when timed out

Relay disabled LED

Under voltage alarm LED

Relay healthy LED

Relay service LED

RS232 configuration port

Page 15: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 15/26

Compact draw out case- Screw terminals- CT shorting available

Micro MATRIXProtection & Control Relay Platform

High accuracy

Simple calibration

Temperature compensation

Page 16: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 16/26

Self supervision- Power supply- Software watchdog

Scaleable I/O

Front accessible opto-isolated programming port

Single PC programsuits all models

Micro MATRIXProtection & Control Relay Platform

Page 17: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 17/26

Firmware control & upgrades

Separate BIOS &application software levels

Micro MATRIXProtection & Control Relay Platform

Page 18: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 18/26

Micro MATRIXProtection & Control Relay Platform

Page 19: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 19/26

uMATRIXwinPC Configuration Screen

Page 20: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 20/26

Front Panel Layout

Page 21: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 21/26

Menu Structure

Page 22: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 22/26

Typical uMATRIX Platform PCB’s

Page 23: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 23/26

uMATRIX Platform HMI PCB

Page 24: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 24/26

2H34 Terminals

Page 25: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 25/26

Customer Generated Ordering Code Generate the required ordering code as follows: e.g. 2H34 BBB

1 2 32H34

1 AUXILIARY SUPPLY RANGE

A 20-70V DC

B 40-275V AC / 300V DC

2 RELAY INITIATE INPUT

Opto-isolated input A 24-80V AC/DCB 75-150V AC/DCC 150-300V AC/DC

3 REMOTE FLAG RESET INPUT

Opto-isolated input A 24-80V AC/DCB 75-150V AC/DCC 150-300V AC/DC

REQUEST DEFAULT APPLICATION SOFTWARE

A 2H34AUMX Frequency OR dF/dt output logic functionB 2H34BUMX Frequency AND dF/dt output logic function

Page 26: 2h34 Application

7/27/2019 2h34 Application

http://slidepdf.com/reader/full/2h34-application 26/26

2H34Additional Information

Technical BulletinUser GuideSoftware downloads

Auto Cad Mounting DrawingsPrice & Availability

www.rmspl.com.au/2H34.htm

Test Manuals

www.rmspl.com.au/search.asp

Other Products

www.rmspl.com.au/Products.htm