Upload
others
View
16
Download
0
Embed Size (px)
Citation preview
Last Update ALLU 31/05/2016
Installation Instruction
WIRELESS CONTROL DIM8
A
A
B
B
A+
1Ref: 300 90 004 ED8
2
Beschermd tegen vaste voorwerpen die groter zijn dan 12 mm
Protégé contre les objets solides de plus de 12 mm
Geschützt gegen Festkörper größer als 12 mm
Protected against solid objects greater than 12 mm
Protegido contra objetos sólidos superiores a 12 mm
Protetto contro oggetti solidi più grandi di 12 mm
Goederen zijn dubbel geïsoleerd - geen aarding nodig
Les produits ont une isolation double et ne peuvent pas être mis à la terre
Güter sind doppelt isoliert und müssen nicht geerdet werden
Goods have double insulation and must not be grounded
Los productos tienen u aislamiento doble y no se pueden conectar a tierra
I proditti possiedono un doppio isolamento e non devono essere collegati a terra
36,3
14
40,4
85-240V / 50-60Hz
Max. 0.65A
+/-7mm
L
N
L'
N'
0,75-1,5mm²
L
N
1
L
N
85-240 VAC
19,7 19,7
36,3
39,4
40,4
18,15
18,1512,7
Mounting hole diameter:
3,5 mm
14,0
LN
N
L N
N
L N
N
Wire info:
Solid and stranded: 0,5-1,5 mm² / 16-20AWG
3 TECHNICAL DATA
2Ref: 300 90 004 ED8
Installation Instruction
mesh network technologyDevice acts also as a repeater. Longer ranges can
be achieved by using multiple Casambi units.
50 m 1)Up to
40 m 1)
Range is highly dependant on the surrounding and obstacles, such as walls and building materials.1)
INPUT
Voltage range: 85-240VFrequency: 50-60HzMax.mains current: 0,65A
OUTPUT
Dimming method: Trailing-edge phase controlMax. output power:Incandescent and high voltage halogen bulbs 150W @ 230VAC 70W @ 110VACHigh voltage ACLED modules: 150W @ 230VAC 70W @ 110VACDimmable LED and CFL bulbs: 50W @ 230VAC 25W @ 110VACDimmable Electronictransformers: 50W @ 230VAC 25W @ 110VACMax. output current: 0,65AMin. load requirement: 1WMax. current pulse: 4A
RADIO TRANSCEIVER
Operating frequencies: 2,4...2,483 GhzMaximum output power: +4 dBm
OPERATING CONDITIONS
Ambient temperature, TA: -20...+45°CMax. case temperature, TC : +65°CStorage temperature: -25...+75°CMax. relative humidity: 0...80%, non cond
CONNECTORS
Wire range, solid & stranded: 0,5-1,5mm² 16-20AWGWire strip length: 6-8mm
MECHANICAL DATA
Dimensions: 40,4 x 36,3 x 14 mmWeigth: 15gDegree of protection: IP20 (Indoor)
Never connect inductive loads, such as iron core transformers.
This could cause permanent damage to the dimmer.
Do not mix di�erent types of loads.
1) Dimming quality depends solely on the load electronics.2) Do not connect more than two electronic transformers to one CBU-TED.3) Some LED modules may �icker at low dimming levels.
LOAD SUITABLITY
TYPE OF LOAD MAX. LOAD Incandescent and High voltage halogens (R) 150WHigh quality dimmable LED bulbs (C)1) 50WHigh quality dimmable CFL bulbs (C)1) 50WTrailing edge dimmable LED drivers (C)1) 2) 50WLow voltage halogens withelectronic transformers(C)1) 2) 50WHigh voltage AC LED modules(R)3) 150WLuminescent lamps, non-dimmable LED and CFL bulbs (C) NOT ALLOWEDWire wound transformers, electric motors and other inductive loads (l) NOT ALLOWED