3127-I-HD-010-B.pdf

Embed Size (px)

Citation preview

  • 8/10/2019 3127-I-HD-010-B.pdf

    1/4

    REV: BSh..: 1

    Of: 4

    AST N3127-I-HD-010 REV: B

    CLIENT: TRANSIERRA S.A

    JOB: GASYRG ESTACION DE COMPRESION VILLAMONTES

    JOB N: 3127

    DATA SHEET

    WATER TANKS LEVEL SWITCH

    B 2-7-2003 ISSUE FOR CONSTRUCTION DP OS GN

    A 5-6-2003 ISSUE FOR CONSTRUCTION DP OS GN

    0 20-2-2003 ISSUE FOR APPROVAL DP OS GN

    REV. DATE DESCRIPTION BY CHKD. APPROVAL

    TSR N: I-FD-7010.00-6240-800-AEV-010

  • 8/10/2019 3127-I-HD-010-B.pdf

    2/4

    Rev.: BSh.: 2

    Of: 4

    CLIENT: TRANSIERRA S.A.

    JOB: GASYRG ESTACION DE COMPRESION VILLAMONTES

    SERVICE LOCATION P&ID MANUFACTURER MODEL SHEET NOTES

    LSHL - 290 TK-0201 Field 3127-F-PI-018 SOR / 733A-F4C-B-A2-N4-SLTTX, SL=4 m, X= FF flange 3 1

    LSHL - 302 Service water TK Field 3127-F-PI-018 Bruno Schillig / CLM-R2ICE 4 1, 2

    3127-F-PI-009 a 022 Rev B

    2) Quantity : two (2)

    TSR N: I-FD-7010.00-6240-800-AEV-010

    AST N: 3127-I-HD-010

    DISPLACER LEVEL SWITCH LIST

    1. P&IDs

    N!TAG

    References:

    Notes

    1) Level switch shall be provided with TAG identification.

    B

    3127-I-HD-010-B

  • 8/10/2019 3127-I-HD-010-B.pdf

    3/4

    43

    LSHL -290

    TK-0201

    TK-0201 3127-F-PI-018

    Water

    kg/m! 1000 kg/m!

    0,34

    60 C

    A-105 SST

    20 kg/cm2 (38"C)

    4"

    FF 150#

    190 mm lenght 64 mm diameter, two displacer

    AISI 316/316L

    MFR STD

    4 m

    Switch

    NEMA 4 (IP65), aluminium housing

    24 VDC

    1" NPT

    2 SPDT

    5A 24 VDC

    Hight: level increase contact open; Low: L. decrease - open

    SOR

    733A-F4C-B-A2-N4-SLTTX, SL=4 m, X= FF flange

    Instrument shall be provided with TAG identification

    1

    2

    GENERAL 3 P&ID No.

    4

    5

    6

    7

    8 Density Lower

    PROCESS 9 Oper. Pressure

    CONDITIONS10 Oper. Temperature

    11

    1213

    14

    15

    16

    17

    18

    19

    BODY / GAGE 20

    21

    22

    23

    24

    2526

    27

    28

    29

    30

    DISPLACER 31

    OR FLOAT 32 Tube Material

    33

    34

    35

    36

    37

    38

    39TRANSMITTER

    40

    41

    42

    43

    44

    45

    46 Supply Gage

    47

    OPTIONS 48

    49 Form

    50

    51

    52

    53

    PURCHASE 54

    55 Item Number

    56

    Notes:

    INSTRUMENT SPECIFICATION

    B

    A

    0 Sheet of

    No. By Date Revision Rev.: B

    Tag Number

    Service

    Vessel No.

    Upper Liquid

    Lower Liquid

    Density Upper

    Max. Pressure

    Max. Temperature

    Body or Gage Material

    Rating

    Connection Size & Location Upper

    Type

    Connection Size & Location Lower

    Type

    Case Mounting

    Type

    Rotatable Head

    Orientation

    Cooling Extension

    Select Standard Span

    Insertion Depth

    Displacer Extension

    Displacer or Float Material

    Spring Material

    Function

    Output

    Control Modes

    Calibration Range Min.

    Output Action: Level Rise

    Mounting

    Enclosure Class

    Electrical Power or Air Supply

    Airset

    Gage Glass Connection

    Gage Glass Model No.

    Contacts: No.

    Contact Rating

    Action of Contacts

    Manufacturer

    Model

    Purchase Order Number

    Price

    Serial Number

    03/07/2003

    05/06/2003

    20/02/2003

    Code:3

    Displacer Level Instrument

    kgf/cm#-g kgf/cm#-g

    C

    Max.

    -

    DP

    DP

    DP

    Issue for construction

    Issue for construction

    Issue for approval

    Dwg. No.: 3127-I-HD-010

    FieldLocation

    SWITCH

    Cable Lenght

    Electrical or Air Connection

  • 8/10/2019 3127-I-HD-010-B.pdf

    4/4

    44

    LSHL -302

    Service water tank

    3127-F-PI-018

    Air

    Water

    kg/m! 1000 kg/m!

    0

    60 C

    AISI 316

    2" side

    NPT

    50 mm diameter

    AISI 316

    SWITCH

    ON/OFF

    IP65, aluminum housing

    24 VDC

    1/2" NPT

    1 reed switch

    Hight: level increase contact open; Low: L. decrease - open

    BRUNO SCHILLIG

    CLM-R2ICE

    Instrument shall be provided with TAG identification. quantity: two (2)

    1

    2

    GENERAL 3 P&ID No.

    4

    5

    6

    7

    8 Density Lower

    PROCESS 9 Oper. Pressure

    CONDITIONS10 Oper. Temperature

    11

    1213

    14

    15

    16

    17

    18

    19

    BODY / GAGE 20

    21

    22

    23

    24

    2526

    27

    28

    29

    30

    31FLOAT

    32 Tube Material

    33

    34

    35

    36

    37

    38

    39TRANSMITTER

    40

    41

    42

    43

    44

    45

    46 Supply Gage

    47

    OPTIONS 48

    49 Form

    50

    51

    52

    53

    PURCHASE 54

    55 Item Number

    56

    Notes:

    INSTRUMENT SPECIFICATION

    B Sheet of

    No. By Date Revision Rev.: B

    Tag Number

    Service

    Upper Liquid

    Lower Liquid

    Density Upper

    Max. Pressure

    Max. Temperature

    Body or Gage Material

    Rating

    Connection Size & Location Upper

    Type

    Connection Size & Location Lower

    Type

    Case Mounting

    Type

    Rotatable Head

    Orientation

    Cooling Extension

    Select Standard Span

    Insertion Depth

    Displacer Extension

    Float Material

    Spring Material

    Function

    Output

    Control Modes

    Calibration Range Min.

    Output Action: Level Rise

    Mounting

    Enclosure Class

    Electrical Power or Air Supply

    Airset

    Gage Glass Connection

    Gage Glass Model No.

    Contacts: No.

    Contact Rating

    Action of Contacts

    Manufacturer

    Model

    Purchase Order Number

    Price

    Serial Number

    03/07/2003

    Code:84

    Float Level Instrument

    kgf/cm#-a kgf/cm#-a

    C

    Max.

    -

    DP Issue for construction

    Dwg. No.: 3127-I-HD-010

    FieldLocation

    SWITCH

    Electrical or Air Connection

    Area Clasiffication