3
936.5174/a Subject to alteration. Page 1 of 3 78211457, 78211458 Designed for co-siting purposes Enables feeder sharing Integrated auto-sense technology for automatic DC / AISG detection and bypass functionality. Combine Mode (near BTS): DC/AISG auto-sense for port 1…3 and short circuit detection on port 4. The first port (1, 2 or 3) which is supplied with a DC/AISG signal wil automatically be by-passed to port 4 Split Mode (near antenna): Automatic DC/AISG by-pass from port 4 to port 1…3 if no short circuit is detected A detailed manual about auto-Sense technology can be downloaded on our homepage. Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection Technical Data Type No. 78211457 Single Unit 78211458 Double Unit Pass band Band 1 Band 2 Band 3 [MHz] [MHz] [MHz] 380 – 960 1350 – 2200 2300 – 2690 Insertion loss Port 1 Port 4 Port 2 Port 4 Port 3 Port 4 [dB] [dB] [dB] < 0.2 (380 – 960 MHz) < 0.2 (1350 – 2200 MHz) < 0.2 (2300 – 2690 MHz) Isolation [dB] > 50 VSWR < 1.25 Impedance [Ω] 50 Input power Band 1 / Band 2 / Band 3 [W] < 300 / < 200 / < 200 Intermodulation products [dBc] < −160 (3 rd order; with 2 x 20 W) Temperature range [°C | °F] −40 ... +60 | −40 ... +140 Connectors 4.3-10 female (long neck) Application Indoor or outdoor (IP 66) DC/AISG transparency Port 1 Port 4 Port 2 Port 4 Port 3 Port 4 [mA] [mA] [mA] Auto-sense (max. 2000) Auto-sense (max. 2000) Auto-sense (max. 2000) Lightning protection [kA] 3, 10/350 µs pulse Mounting [mm | in] Wall mounting: With 4 screws (max. 8 | 0.315 diameter) / Mast mounting: With included clamp set Weight [kg | lb] Single Unit: 3.7 | 8.2 / Double Unit: 7.2 | 15.9 Dimensions (w x h x d) [mm | in] Single Unit: 196.9 x 214.7 x 67.65 | 7.75 x 8.45 x 2.66 / Double Unit: 196.9 x 214.7 x 138.65 | 7.75 x 8.45 x 5.45 (without connectors, without mounting brackets) Triple-Band Combiner 380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz – 2690 Single Unit Double Unit clamps included Port 1 Port 2 Port 3 Port 4 AUTO- SENSE Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz · in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4. The installation team

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz · in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4. The installation team

936.

5174

/a

Sub

ject

to

alte

ratio

n.

Page 1 of 378211457, 78211458

• Designed for co-siting purposes

• Enables feeder sharing

• Integrated auto-sense technology for automatic DC / AISG detection andbypass functionality.

Combine Mode (near BTS):DC/AISG auto-sense for port 1…3 and short circuit detection on port4. The first port (1, 2 or 3) which is supplied with a DC/AISG signal wilautomatically be by-passed to port 4

Split Mode (near antenna):Automatic DC/AISG by-pass from port 4 to port 1…3 if no short circuit is detected

A detailed manual about auto-Sense technology can be downloaded on our homepage.

• Suitable for indoor or outdoor applications

• Wall or mast mounting

• Available as a single unit, or for XPol antennas as a double unit

• Built-in lightning protection

Technical Data

Type No. 78211457Single Unit

78211458Double Unit

Pass band Band 1 Band 2 Band 3

[MHz][MHz][MHz]

380 – 9601350 – 22002300 – 2690

Insertion loss Port 1 ↔ Port 4 Port 2 ↔ Port 4 Port 3 ↔ Port 4

[dB][dB][dB]

< 0.2 (380 – 960 MHz)< 0.2 (1350 – 2200 MHz)< 0.2 (2300 – 2690 MHz)

Isolation [dB] > 50

VSWR < 1.25

Impedance [Ω] 50

Input power Band 1 / Band 2 / Band 3 [W] < 300 / < 200 / < 200

Intermodulation products [dBc] < −160 (3rd order; with 2 x 20 W)

Temperature range [°C | °F] −40 ... +60 | −40 ... +140

Connectors 4.3-10 female (long neck)

Application Indoor or outdoor (IP 66)

DC/AISG transparency Port 1 ↔ Port 4 Port 2 ↔ Port 4 Port 3 ↔ Port 4

[mA][mA][mA]

Auto-sense (max. 2000) Auto-sense (max. 2000) Auto-sense (max. 2000)

Lightning protection [kA] 3, 10/350 µs pulse

Mounting [mm | in] Wall mounting: With 4 screws (max. 8 | 0.315 diameter) / Mast mounting: With included clamp set

Weight [kg | lb] Single Unit: 3.7 | 8.2 / Double Unit: 7.2 | 15.9

Dimensions (w x h x d) [mm | in] Single Unit: 196.9 x 214.7 x 67.65 | 7.75 x 8.45 x 2.66 / Double Unit: 196.9 x 214.7 x 138.65 | 7.75 x 8.45 x 5.45

(without connectors, without mounting brackets)

Triple-Band Combiner

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz

– 2690––

Single Unit

Double Unit

clamps

included

Port 1

Port 2

Port 3

Port 4

AUTO- SENSE

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]

Page 2: 380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz · in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4. The installation team

936.

5174

/a

Sub

ject

to

alte

ratio

n.

Page 2 of 3 78211457, 78211458

Please Note:

The mounting plates can be removed by loosening the screws j to m (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions.

Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of a mast mounted device or even cause it to fall to the ground.

These facts must be considered during the site planning process.

The Combiners are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4.

The installation team must be properly qualified and also be familiar with the relevant national safety regulations.

The details given in our data sheets have to be followed carefully when installing the combiners and accessories.

The limits for the coupling torque of RF connectors, re- commended by the connector manufacturers must be obeyed.

Terminate unused inputs with a suitable 50-Ohm load, e.g. 78210484.

Any previous datasheet issues have now become invalid.

Clamp Set

50-Ohm load

Type No. Clamp set suitable for mast diameter of

734365 [mm | in] 45 – 125 | 1.77 – 4.92

Type No. Description

78210484 50-Ohm load

Accessories (included)

Triple-Band Combiner

Accessories (order separately)

Typical Attenuation Curves

Diagram 1

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900

380 - 960

Atte

nuat

ion

/ dB

Frequency / MHz

Port 1↔Port 4 Port 3↔Port 4Port 2↔Port 4

1350 - 2200 2300 - 2690

Diagram 2

-1,00

-0,90

-0,80

-0,70

-0,60

-0,50

-0,40

-0,30

-0,20

-0,10

0,00

300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900

380 - 960

Atte

nuat

ion

/ dB

Frequency / MHz

Port 1↔Port 4 Port 3↔Port 4Port 2↔Port 4

1350 - 2200 2300 - 2690

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]

All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com

Page 3: 380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz · in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4. The installation team

936.

5174

/a

Sub

ject

to

alte

ratio

n.

78211457, 78211458 Page 3 of 3

Dimensions

Triple-Band Combiner

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz