3G DT Introduction

Embed Size (px)

Citation preview

  • 8/10/2019 3G DT Introduction

    1/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Prepared by

    Ahmed Montaser Sr.RNO EngineerMob: 01116368468

    E-mail: [email protected]

  • 8/10/2019 3G DT Introduction

    2/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    3G Field Problems

  • 8/10/2019 3G DT Introduction

    3/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    1. Cross sector.

    2. Cross feeder.

    3. Pilot pollution.

    4. Missing Neighbors.

    5. Overshooting

    6. Delayed Soft HO

    7. HO From UTRAN Failures.

    8. Dropped calls.

    9. Blocked calls.

    10.Hardware problem

    3G Field Problems

  • 8/10/2019 3G DT Introduction

    4/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Cross sector

  • 8/10/2019 3G DT Introduction

    5/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    This is the normal connection

  • 8/10/2019 3G DT Introduction

    6/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    UMTS cross sector

    UMTS cross

  • 8/10/2019 3G DT Introduction

    7/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    EX: UMTS cross sector

    Sector 3 serve beside sec 2 and vice versa Cross sector between sec 2 & sec 3

  • 8/10/2019 3G DT Introduction

    8/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    After solving the cross sector

    Sectors 3 serve beside itself and its the dominant server and sector 2 serve beside itself too

  • 8/10/2019 3G DT Introduction

    9/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Cross feeder

  • 8/10/2019 3G DT Introduction

    10/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    UMTS cross feeder Case #1

  • 8/10/2019 3G DT Introduction

    11/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    2-Cross feeder (Case # 1)

    Sector 1 & sector 3 appeared with equal levels beside sector 3 and vice versa

    cross feeder between sector 1 & sector 3

  • 8/10/2019 3G DT Introduction

    12/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    After solving the cross Feeder

    Sectors 3 serve beside itself and sector 1 serve beside itself too

  • 8/10/2019 3G DT Introduction

    13/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    UMTS cross feeder Case # 2

  • 8/10/2019 3G DT Introduction

    14/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    2-Cross feeder (Case # 2)

    Sector 2 serve normally beside itself but the Tx power (UL power is very largecompared with UE distance, the same case for sector 3

  • 8/10/2019 3G DT Introduction

    15/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    After solving the cross Feeder

  • 8/10/2019 3G DT Introduction

    16/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Pilot Pollution

  • 8/10/2019 3G DT Introduction

    17/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Pilot pollution:

    The presence of more than a pilot with level difference within 5 dBm causing low

    Ec/No all of them are strong but no one is strong enough to be dominant regardingthat they are of the same frequency

    i d i

  • 8/10/2019 3G DT Introduction

    18/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    i I d i

  • 8/10/2019 3G DT Introduction

    19/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Missing Neighbors

    D i T I d i

  • 8/10/2019 3G DT Introduction

    20/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Missing Neighbor:

    The presence of a detected neighbor with high RSCP for a period without adding to the

    AS list causing degradation in Ec/No

    D i T t I t d ti

  • 8/10/2019 3G DT Introduction

    21/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Overshooting

    D i T t I t d ti

  • 8/10/2019 3G DT Introduction

    22/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    D i T t I t d ti

  • 8/10/2019 3G DT Introduction

    23/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Delayed soft HO

    D i T t I t d ti

  • 8/10/2019 3G DT Introduction

    24/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    There is delayed soft HO due to Radio link congestion on cell with SC:218 or it may

    be wrong SHO parameter (AS update parameters).

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    25/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    26/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    HO from UTRAN failure

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    27/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    1. HO Failure reasons.

    Interference on Target 2G Cell.

    Bad Rxlev on Target 2G Cell.

    Interference on Serving 3G Cell.

    Bad Rxlev on Serving 3G Cell.

    2G Field Problems

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    28/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Delayed Soft HO which leads to make HO from UTRAN but HO from UTRAN failed.

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    29/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Dropped call

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    30/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    3. Dropped call reasons.

    Bad Radio condition (Bad RSCP or EcNo or both of them) due to the following:

    1) Pilot pollution .

    2) Delayed SHO Congestion or wrong SHO parameter definition.

    3) HO from UTRAN Failure.

    4) Missing neighbor (Bad Rx level).

    5) Over shooting.

    6) Poor coverage.

    Note: all mentioned reasons make a dropped call in case of no HO from UTRAN occurredsuccessfully.

    Transmission problem (Not RF problem)

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    31/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Dropped call due to pilot pollution & no HO from UTRAN occurred.

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    32/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Dropped call due to delayed SHO& no HO from UTRAN occurred.

  • 8/10/2019 3G DT Introduction

    33/42

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    34/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Dropped call due to Missing neighbor & no HO from UTRAN occurred..

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    35/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Dropped call due to overshooting& no HO from UTRAN occurred.

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    36/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Dropped call due to Transmission problem (Not RF problem)

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    37/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Blocked call

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    38/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    4. Blocked call reasons.

    Bad Radio condition (Bad RSCP or EcNo or both of them) due to the following:

    1) Pilot pollution .

    2) Delayed SHO Congestion or wrong SHO parameter definition.

    3)Missing neighbor (Bad Rx level).

    4) Over shooting.

    5) Poor coverage.

    Note: all mentioned reasons make a Blocked call in case of no cell reselection from UTRANoccurred.

    Congestion.

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    39/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Blocked call due congestion.

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    40/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Hardware problem

    Drive Test Introduction

  • 8/10/2019 3G DT Introduction

    41/42

    Drive Test Introduction

    Prepared by Eng. Ahmed Montaser

    Hardware problem

  • 8/10/2019 3G DT Introduction

    42/42