32
Alcatel-Lucent 7360 INTELLIGENT SERVICES ACCESS MANAGER | RELEASE 4.3 SAFETY MANUAL 3HH-10126-AAAA-TCZZA Edition 01 Released Alcatel-Lucent Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright 2011 © Alcatel-Lucent. All rights reserved.

3hh 10126 Aaaa Tczza 01 7360 Isam Safety Manual Etsi_ansi

Embed Size (px)

DESCRIPTION

isam 7360

Citation preview

  • Alcatel-Lucent 7360INTELLIGENT SERVICES ACCESS MANAGER | RELEASE 4.3S A F E T Y M A N U A L

    3HH-10126-AAAA-TCZZA Edition 01 Released

    Alcatel-Lucent ProprietaryThis document contains proprietary information of Alcatel-Lucent and is not to be disclosedor used except in accordance with applicable agreements.Copyright 2011 Alcatel-Lucent. All rights reserved.

  • When printed by Alcatel-Lucent, this document is printed on recycled paper.

    Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.

    Copyright 2011 Alcatel-Lucent.All rights reserved.

    Disclaimers

    Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications.This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products.However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers.This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.

  • Alcatel-Lucent 7360 ISAM R4.3 July 2011 iii3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Preface

    This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager (7360 ISAM FX).

    Scope

    This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software upgrade and migration procedures.

    Audience

    This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX.

    Required knowledge

    The reader must be familiar with general telecommunications principles.

    Acronyms and initialisms

    The expansions and optional descriptions of most acronyms and initialisms appear in the glossary, which is included in the System Description document.

  • Preface

    iv July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    Assistance and ordering phone numbers

    Alcatel-Lucent provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://www.alcatel-lucent.com/myaccess.

    For ordering information, contact your Alcatel-Lucent sales representative.

    Safety information

    For safety information, see the Safety Manual for your product.

    Documents

    Refer to the 7360 ISAM Product Information document to see a list of all the relevant customer documents and their part numbers for the current release.

    Customer documentation is available for download from the Alcatel-Lucent Support Service website at http://www.alcatel-lucent.com/myaccess.

    Special information

    The following are examples of how special information is presented in this document.

    Release notes

    Be sure to refer to the release notes (such as the Customer Release Notes or Emergency Fix Release Note) issued for software loads of your product before you install or use the product. The release notes provide important information about the software load.

    Danger Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards.

    Warning Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems.

    Caution Caution indicates that the described activity or situation may, or will, cause service interruption.

    Note A note provides information that is, or may be, of special interest.

  • Contents

    Preface iiiScope ............................................................................................... iiiAudience ............................................................................................... iiiRequired knowledge................................................................................... iiiAcronyms and initialisms ............................................................................. iiiAssistance and ordering phone numbers ........................................................... ivSafety information..................................................................................... ivDocuments .............................................................................................. ivSpecial information.................................................................................... ivRelease notes........................................................................................... iv

    1 Conventions 1-11.1 Introduction.............................................................................. 1-21.2 Safety Instructions in Customer Documentation ................................... 1-21.3 Safety Warning Labels .................................................................. 1-41.4 Waste from Electrical and Electronic Equipment (WEEE)......................... 1-5Alcatel-Lucent 7360 ISAM R4.3 July 2011 v3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    2 Safety Guidelines for 7360 ISAM FX Equipment 2-12.1 Introduction.............................................................................. 2-22.2 Safety Requirements ................................................................... 2-22.3 Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment ............ 2-72.4 Fuses on Power Units and Fan Units................................................. 2-102.5 Environmental Requirements......................................................... 2-142.6 EMC/EMI ................................................................................. 2-152.7 Acoustic Noise .......................................................................... 2-152.8 ITU-T K.20/K.45 Compliance ......................................................... 2-152.9 Ecology................................................................................... 2-16

  • ContentsIndexvi July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

  • Alcatel-Lucent 7360 ISAM R4.3 July 2011 1-13HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    1 Conventions

    1.1 Introduction 1-2

    1.2 Safety Instructions in Customer Documentation 1-2

    1.3 Safety Warning Labels 1-4

    1.4 Waste from Electrical and Electronic Equipment (WEEE) 1-5

  • 1 Conventions

    1-2 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    1.1 Introduction

    This chapter describes the types of safety instructions used in the Hardware Installation Manual and the Unit Data Sheets.

    It gives important safety warning labels found on equipment.

    1.2 Safety Instructions in Customer Documentation

    Safety instructions are placed in customer documentation where the reader should be warned about dangerous or harmful situations or where he should be informed to ease the work.

    Safety instructions can be:

    Person-related or combined person-equipment related Equipment related Other

    Note Familiarize yourself with the safety instructions, warning labels and their meaning before installing, operating or servicing 7360 FX ISAM equipment.

  • 1 Conventions

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 1-33HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Person- or Combined Person-Equipment Related

    Person-Equipment Related

    Danger This instruction warns about an immediately threatening danger.

    It calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in death or serious physical harm.

    In addition, it can warn about a possible equipment-damaging situation or give essential information for avoiding degradation of system operation.

    Do not proceed beyond a danger warning note until the indicated conditions are fully understood and met.

    Warning This instruction warns about a possibly dangerous situation.

    It calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in death or serious physical harm.In addition, it can warn about a possible equipment-damaging situation or give essential information for avoiding degradation of system operation.Do not proceed beyond a warning note until the indicated conditions are fully understood and met.

    Caution This instruction warns about a possibly dangerous situation.

    This warning calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in slight injury.In addition, it can warn about a possible equipment-damaging situation or give essential information for avoiding degradation of system operation.

    Do not proceed beyond a caution note until the indicated conditions are fully understood and met.

    Note 1 This instruction warns about a possibly damaging situation!

    It calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in damage to equipment or to objects in the surrounding environment.Note 2 This instruction gives essential information to avoid degradation of system operation.

  • 1 Conventions

    1-4 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    OthersThese instructions do not warn about dangerous or harmful situations, but give information to ease the work.

    1.3 Safety Warning Labels

    Safety Warning Labels located on equipment call attention to a dangerous situation which, if safety instructions are not correctly performed, could result in bodily harm and/or damage equipment.

    The following items of labels are mandatory in accordance with IEC60950-1 and IEC60825-1:

    Hazardous voltage; see Figure 1-1 High temperature; see Figure 1-2 ESD awareness:

    Devices and assemblies that are susceptible to ElectroStatic Discharge (ESD) are labelled or tagged with the ESD Awareness symbol; see Figure 1-3

    Figure 1-1 Label for Hazardous Voltage Warning

    Figure 1-2 Label for High Temperature Warning

    Caution This Instruction refers to the documentationThe product is marked with this symbol when it is necessary for the user to refer to the instructions in the documentation.

    Note InformationThis note provides information that makes work easier and other useful information.

  • 1 Conventions

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 1-53HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Figure 1-3 ESD Awareness

    1.4 Waste from Electrical and Electronic Equipment (WEEE)

    The product at end of life is subject to separate collection and treatment in the EU Member States, Norway and Switzerland and therefore marked with the WEEE label.

    Figure 1-4 WEEE Label

    Treatment applied at end of life of the product in these countries shall comply with the applicable national laws on wastes from electrical and electronic equipment and more particularly those implementing the European directive 2002/96/EC (WEEE).In countries outside Europe and if not otherwise provided by any mandatory law in those countries where the product is sold, any take back by Alcatel-Lucent of waste electrical and electronic equipment shall be subject to terms and conditions to be agreed upon in writing. Any obligation of Alcatel-Lucent to take back such equipment shall apply only to complete not amended or modified equipment delivered by Alcatel-Lucent, i.e. containing all its components and sub-assemblies.

    In case Alcatel-Lucent takes back electrical and electronic equipment, Alcatel-Lucent will ensure for the ecological safe and appropriate treatment in accordance with local regulations.

  • 1 Conventions

    1-6 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

  • Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-13HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    2 Safety Guidelines for 7360 ISAM FX Equipment

    2.1 Introduction 2-2

    2.2 Safety Requirements 2-2

    2.3 Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment 2-7

    2.4 Fuses on Power Units and Fan Units 2-10

    2.5 Environmental Requirements 2-14

    2.6 EMC/EMI 2-15

    2.7 Acoustic Noise 2-15

    2.8 ITU-T K.20/K.45 Compliance 2-15

    2.9 Ecology 2-16

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-2 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    2.1 Introduction

    This chapter provides general safety guidelines for the:

    7360 ISAM FX-16 equipment (16-slot shelf) 7360 ISAM FX-8 equipment (8-slot shelf) 7360 ISAM FX-4 equipment (4-slot shelf)

    2.2 Safety Requirements

    The 7360 ISAM FX equipment complies with the following safety requirements:

    IEC 60950-1 EN 60950-1 AS/NZ 60950.1 Protection against electric shock: Class I

    Danger Observe safety warnings and instructions

    Observe all warnings on the equipment and in the operating instructions. These warn about potentially hazardous situations that could cause injury to persons. Failure to follow these instructions may also lead to equipment malfunction or damage.

    Carefully follow:

    General safety guidelines in the mandatory regulations Specific safety guidelines and instructions in the 7360 ISAM FX

    Hardware installation manual document for procedures during which hazardous situations may occur.

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-33HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Access AreaThe 7360 ISAM FX shelves are classified as permanently connected equipment and must be installed in a Restricted Access Location (RAL). The inside of the equipment is classified as service access area in accordance with IEC 60950-1

    External InterfacesThe interfaces of the 7360 ISAM FX shelves are classified as follows:

    Table 2-1 External Interfaces

    Warning Risk of hazardous voltages and electric shock by unintentional contact with circuit inside the shelf, when reaching into the empty card slots or contacting internal circuits.

    Hazardous voltages or electric shock can cause serious personal harm or death

    Only qualified service personnel have access to equipment and are allowed to perform installation, operational work or repair work.

    Caution Prevention of access

    The 7360 ISAM FX shelves must be accessible only by authorized personnel. Install the shelves in a restricted access location or similar environment to prevent unauthorized access.

    Interface Classification

    Optical GE XFP Class I Laser product

    Optical GE SFP Class I Laser product

    Optical FE SFP Class I Laser product

    Optical SFP+ Class I Laser product

    EPON SFP Class I Laser product

    GPON SFP Class I Laser product

    Electrical GE Safety Extra Low Voltage (SELV) circuit

    Electrical FE SELV circuit

    BITS SELV circuit

    Craft Terminal SELV circuit(for configuration purposes by personnel only)

    CO Alarm TNV-2 circuit

    External Power Lines TNV-2 circuit, when using 60 VDC batterySELV circuit, when using 48 VDC battery

    Alarm/Service Power Lines TNV-2 circuit, when using 60 VDC batterySELV circuit, when using 48 VDC battery

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-4 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    SELV

    Connect SELV circuits on this equipment only to other circuits that comply with the requirements of the SELV circuits as defined in IEC 60950-1, EN 60950-1 and AS/NZ 60950.1.

    TNV

    TNV can be classified as TNV1, TNV2 or TNV3.

    TNV1 circuits are telecommunications circuits whose voltages during normal operation do not exceed SELV limits but are subjected to off-premises overvoltages.

    TNV2 circuits are telecommunications circuits whose voltages under normal operation exceed the SELV limits but are not subject to off-premises overvoltages. TNV2 also classifies dc mains suppliers whose voltages during normal operation exceed 60V but do not exceed 80V.

    TNV3 circuits are telecommunications circuits with voltages above SELV limits that are also subject to off-premises overvoltages.

    Connect TNV circuits on this equipment only to other circuits that comply with the requirements of the TNV circuits as defined in IEC 60950-1, EN 60950-1 and AS/NZ 60950.1.

    Equipment Bonding and GroundingThe 7360 ISAM FX equipment is classified as Class 1 laser product according to their protection against electric shock. Protection against electric shock is achieved by:

    Using basic insulation Providing means of connection to the protective earth in the building for those

    conductive parts that are otherwise capable of assuming hazardous voltages if the basic insulation fails.

    The 7360 ISAM FX shelves comply with the following product power and grounding standards:

    ETS 300 253, Earthing and bonding of telecommunication equipment in telecommunication centers

    ETS 300 132-2, Power supply interface at the input to telecommunication equipment: Part 2 Operated by direct DC current.

    7360 ISAM FX equipment is classified as Class 1 Laser Products.

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-53HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Classification of Laser and LED Transmitter Modules

    Normal Laser Operation

    The optical fibre communication systems used in the 7360 ISAM FX shelves consist of a laser transmitter module and an optical receiver. Optical connectors have been provided at:

    the front panel of the NT boards the front panel of the NTIO boards

    These optical connectors are located behind doors.

    In normal operation, the laser transmitter is enclosed by the optical connector and the external optical fibre. Laser radiation is always present when the laser unit is powered on, limited to a maximum accessible emission limit of Class 1 according to IEC 60825-1.

    Laser Transmitter Classification

    The 7360 ISAM FX equipment is classified as Class 1 laser product according to IEC 60825-1.

    LED Classification

    According to the current version of IEC60825-1, LEDS do not exceed the accessible emission limit of Class 1 under all conditions of operation, maintenance, service and failure.

    Optical Fiber Communication System Installation Access

    According to IEC 60825-2, the laser device, when used in a 7360 ISAM FX shelf that is installed in a rack, is classified as a "hazard level 1" product.

    The fibre cables pass through the bottom or top rack entrance. The use of cable supports and guides protects the receptacles from strain.

    The 7360 ISAM FX shelves are located in controlled access locations only (telecom areas) which implies that activity inside the equipment must be executed by trained maintenance personnel only.

    Warning 1 Risk of skin burns when in contact with hot parts!Skin (fingers) can get burns when touching the case of hot devices.The surface temperature must not exceed 70C.Warning 2 Risk of eye damage by laser radiationEyes can get damaged when they are exposed to a laser beam.

    Observe the laser explanatory label, before plugging in the module.

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-6 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    Direct viewing in the laser beam is only possible with a disconnected fibre in an open rack.

    Equipment Protection

    Electrostatic Discharge

    Devices and assemblies that are susceptible to ESD are labeled or tagged with the ESD awareness symbol (Figure 2-1).

    Figure 2-1 ESD Awareness Label

    The necessary precautions must be taken to discharge operating personnel by the use of approved discharge straps/links and a conductive layer on the exchange floor. The maximum resistance to discharge must be 106 .

    Precautions

    The following precautions must be observed:

    Wear an antistatic wristband when: Replacing plug-in units Operating circuit breakers The ESD awareness label (Figure 2-1) is present;

    Do not wear or use clothes made of wool, nylon, or any synthetic material; such fabrics are major sources of static build-up

    When handling plug-in units, do not use gloves and finger covers, unless they are made of cotton

    Always handle the boards by the edges Do not touch conductor paths with fingers or palms Remove the antistatic wristband and connection cord after use. They must not be

    left connected to the shelf or left inside the rack when not used.

    Earth bonding points for the wristband are provided on the shelf or in the rack and are indicated by the label as shown in Figure 2-2.

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-73HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Figure 2-2 Label for Earth Bonding Point

    2.3 Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment

    This section gives an overview of the power rating of circuit breakers, switches and fuses located on:

    Circuit Breakers on 7360 ISAM FX-16 equipment Circuit Breakers on 7360 ISAM FX-8 equipment Fuses on 7360 ISAM FX-4 equipment

    General Warning

    Warning Electrical shock hazard due to battery voltage present at connectors.

    Risk of personnel injury at unintentional contact with connectors.The service personnel has to be protected against the battery voltage present on the connectors.

    Before removing a board from the subrack, switch off the circuit breaker feeding that subrack.

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-8 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    Circuit Breakers on 7360 ISAM FX-16 equipmentThe circuit breakers of the 7360 ISAM FX-16 shelves are located on the front panel of the power unit of the shelf. The equipment contains two circuit breakers, one for each redundant power branch (BATA and BATB).Figure 2-3 shows the location of the fuses on the FX-16 shelf.

    Figure 2-3 Fuses on FX-16 Slot Shelf

    Table 2-2 Circuit Breakers on 8 & 16 Slot Shelf

    Circuit Breakers on 7360 ISAM FX-8 equipmentThe circuit breakers of the 7360 ISAM FX-8 shelves are located on the front panel of the power unit of the shelf. The equipment contains two circuit breakers, one for each redundant power branch (BATA and BATB).Figure 2-4 shows the location of the fuses on the FX-8 shelf.

    Figure 2-4 Fuses on FX-8 Slot Shelf

    Table 2-3 Circuit Breakers on 8-Slot Shelf

    Equipment Type Circuit Breaker Type

    7360 ISAM FX-16 (NFXS-D) 70 A (dual pole 2 x 35 A)

    Circuit breakers

    Equipment Type Circuit Breaker Type

    7360 ISAM FX-8 (NFXS-E) 40 A (single pole)

    B/40 A

    A/40 A

    Circuit breaker

    Circuit breaker

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-93HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Fuses on 7360 ISAM FX-4 equipmentThe fuses of the 7360 ISAM FX-4 shelves are located on front panel of the power unit of the shelf. The equipment contains six fuses, three for each redundant power branch (BATA and BATB).Figure 2-5 shows the location of the fuses on an FX-4 slot shelf.

    Figure 2-5 Fuses on FX-4 Slot Shelf

    Table 2-4 Fuses on 4-Slot Shelf

    Equipment Type Fuse Type

    7360 ISAM FX-4 (NFXS-F) 10 A (cartridge 5x20mm slow blow, T10AH/250V)

    Fuses

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-10 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    2.4 Fuses on Power Units and Fan Units

    This section gives an overview of the fuses used on the power units and the fan units of the 7360 ISAM FX-16, FX-8 and and FX-4 shelves.

    Fuses on 7360 ISAM FX-16 Power Unit Fuses on 7360 ISAM FX-8 Power Unit Fuses on 7360 ISAM FX-4 Power Unit Fuses on 7360 ISAM FX-16 Fan Unit (EFCU-E) Fuses on 7360 ISAM FX-8 Fan Unit (EFCU-D) Fuses on 7360 ISAM FX-4 Fan Unit (EFCU-G)

    Fuses on 7360 ISAM FX-16 Power UnitTable 2-5 lists the fuses on the power unit (PDBP-B) of the 7360 ISAM FX-16 subrack.

    Table 2-5 Fuses on NFXS-D

    Fuses on 7360 ISAM FX-8 Power UnitTable 2-6 lists the fuses located on the power board NGFC-E of the 7360 FX-8 subrack.

    Fuse Number Fuse Rating Fuse Type

    F1 125V/10A Quick / SMD

    F2 125V/10A Quick / SMD

    F3 125V/10A Quick / SMD

    F4 125V/10A Quick / SMD

    F5 125V/10A Quick / SMD

    F6 125V/10A Quick / SMD

    F7 125V/10A Quick / SMD

    R85 72V/900mA Radial PTC / leaded

    R86 72V/900mA Radial PTC / leaded

    R87 72V/900mA Radial PTC / leaded

    R88 72V/900mA Radial PTC / leaded

    R89 72V/900mA Radial PTC / leaded

    R252 72V/1,6A Radial PTC / leaded

    R253 72V/1,6A Radial PTC / leaded

    R254 72V/1,6A Radial PTC / leaded

    R445 72V/900mA Radial PTC / leaded

    R459 72V/900mA Radial PTC / leaded

    R460 72V/900mA Radial PTC / leaded

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-113HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Table 2-6 Fuses on NGFC-E

    Fuses on 7360 ISAM FX-4 Power UnitTable 2-7 lists the fuses located on the power board NGFC-F of the 7360 FX-4 subrack.

    Table 2-7 Fuses on NGFC-F

    Fuse Number Fuse Rating Fuse Type

    F1 125 V / 10 A Quick / SMD

    F2 125 V / 10 A Quick / SMD

    F3 125 V / 10 A Quick / SMD

    F4 125 V / 10 A Quick / SMD

    F5 125 V / 10 A Quick / SMD

    R85 72 V / 900 mA Radial PTC / leaded

    R86 72 V / 900 mA Radial PTC / leaded

    R88 72 V / 900 mA Radial PTC / leaded

    R89 72 V / 900 mA Radial PTC / leaded

    R252 72V/1,6A Radial PTC / leaded

    R253 72V/1,6A Radial PTC / leaded

    R254 72V/1,6A Radial PTC / leaded

    R304 72V/900mA Radial PTC / leaded

    R305 72V/900mA Radial PTC / leaded

    R306 72V/900mA Radial PTC / leaded

    Fuse Number Fuse Rating Fuse Type

    F1 125 V / 10 A Quick / SMD

    F2 125 V / 10 A Quick / SMD

    F3 125 V / 10 A Quick / SMD

    F4 125 V / 10 A Quick / SMD

    F5 125 V / 10 A Quick / SMD

    R85 72 V / 900 mA Radial PTC / leaded

    R86 72 V / 900 mA Radial PTC / leaded

    R87 72 V / 900 mA Radial PTC / leaded

    R88 72 V / 900 mA Radial PTC / leaded

    R89 72 V / 900 mA Radial PTC / leaded

    R252 72V/1,6A Radial PTC / leaded

    R253 72V/1,6A Radial PTC / leaded

    (1 of 2)

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-12 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    Fuses on 7360 ISAM FX-16 Fan Unit (EFCU-E)Table 2-8 lists the fuses on the 7360 ISAM FX-16 fan unit.

    Table 2-8 Fuses on 7360 ISAM FX-16 Fan Unit

    Fuses on 7360 ISAM FX-8 Fan Unit (EFCU-D)Table 2-9 lists the fuses on the 7360 ISAM FX-8 fan unit.

    Table 2-9 Fuses on 7360 ISAM FX-8 Fan Unit

    R254 72V/1,6A Radial PTC / leaded

    R413 72V/900mA Radial PTC / leaded

    R414 72V/900mA Radial PTC / leaded

    R415 72V/900mA Radial PTC / leaded

    R416 72V/900mA Radial PTC / leaded

    R461 72V/900mA Radial PTC / leaded

    R462 72V/900mA Radial PTC / leaded

    Fuse Number Fuse Rating Fuse Type

    (2 of 2)

    Fuse Number Fyse Rating Fuse Type

    F1 125V/2,5A Slow / SMD

    F2 125V/2,5A Slow / SMD

    F3 125V/1,5A Quick / SMD

    F4 125V/1,5A Quick / SMD

    F5 125V/1,5A Quick / SMD

    F6 125V/1,5A Quick / SMD

    F7 125V/1,5A Quick / SMD

    F8 125V/1,5A Quick / SMD

    F9 125V/1,5A Quick / SMD

    F10 125V/1,5A Quick / SMD

    Fuse Number Fyse Rating Fuse Type

    F1 125V/1,5A Slow / SMD

    F2 125V/1,5A Slow / SMD

    F3 125V/1,5A Slow / SMD

    F5 125V/1,5A Slow / SMD

    F6 125V/1,5A Slow / SMD

    (1 of 2)

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-133HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Fuses on 7360 ISAM FX-4 Fan Unit (EFCU-G)Table 2-10 lists the fuses on the 7360 ISAM FX-4 fan unit.

    Table 2-10 Fuses on 7360 ISAM FX-4 Fan Unit

    Fuses on Plug-in Units

    Table 2-11 gives an overview of the fuse rating of the various plug-in units (with number, rating and type) applied in the 7360 FX subracks.

    Table 2-11 Fuse Rating of Plug-in Units applied in FX subracks

    F7 125V/1,5A Slow / SMD

    F9 125V/2,5A Slow / SMD

    F10 125V/2,5A Slow / SMD

    Fuse Number Fyse Rating Fuse Type

    (2 of 2)

    Fuse Number Fuse Rating Fuse Type

    F1 125V/1,5A Quick / SMD

    F2 125V/1,5A Quick / SMD

    F3 125V/1,5A Quick / SMD

    F4 125V/1,5A Quick / SMD

    F5 125V/1,5A Quick / SMD

    Warning Risk of malfunctioning due to replacement with wrong fuse.Applying fuses on plug-in units with ratings different from the prescribed could result in damage to the equipment.

    Always replace with fuses which have the prescribed rating.

    Mnemonic Board Code Fuse Number Fuse Rating Fuse Type

    FANT-F 3FE 53699 XX F1 125V/6.3A Quick / SMD

    F3 125V/0.5A Quick / SMD

    F4 125V/0.5A Quick / SMD

    F5 125V/6.3A Quick / SMD

    FNIO-B 3FE 54057 AA F1 125V/3.15 Fuse, quick

    F2 125V/0.5A Fuse, quick

    (1 of 2)

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-14 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    2.5 Environmental Requirements

    The 7360 ISAM FX equipment meets the environmental criteria defined by ETS 300 019-1-X: Equipment Engineering (EE): Environmental conditions and environmental tests for telecommunication equipment.

    The 7360 ISAM FX equipment complies with the following classes:

    StorageStorage is according to ETSI EN 300 019-1-1, Class 1.1:

    Weather protected, partly temperature controlled storage locations.

    TransportationTransport according to ETSI EN 300 019-1-2 - Class 2.3:

    Packed, public transportation. No rain on packing allowed.

    Stationary UseStationary use of the 7360 ISAM FX equipment is in accordance with ETS 300 019-1-3 Class 3.1E for multi-shelf configurations:

    Stationary use in temperature controlled locations.

    Stationary use of the 7360 ISAM FX equipment according ETS 300 019-1-3 Class 3.3* for single-shelf configurations.

    Stationary use in not temperature-controlled locations No condensation allowed No conditions of wind-driven rain, snow, hail, water from other sources than rain

    allowed.

    NELT-B 3FE 62543 AA F1 125 V / 500 mA Fuse, quick

    F1P0 125 V / 3.15 A Fuse, quick

    NGLT-A 3FE 64279 AA F3 125 V / 5 A Fuse, quick

    FPLT-A 3FE 53711 AA F1 125 V / 4 A Fuse, quick

    F2 125 V / 500 mA Fuse, quick

    F3 125 V / 500 mA Fuse, quick

    Mnemonic Board Code Fuse Number Fuse Rating Fuse Type

    (2 of 2)

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    Alcatel-Lucent 7360 ISAM R4.3 July 2011 2-153HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    2.6 EMC/EMI

    The 7360 ISAM FX equipment complies with the following Electromagnetic Compatibility (EMC) and Electromagnetic Immunity (EMI) specifications: ETSI EN 300 382-2 telecommunication centre installation environment ETSI EN 300 386-2 telecommunication centre installation environment ETSI EN 201 468 for telecommunication centres, level 2 EN 61000-4-2 ESD EN 61000-4-3 Radiated immunity EN 61000-4-4 EFT EN 61000-4-5 Surge EN 61000-4-6 Low Frequency common immunity EN 55022, CISPR22, AS/NZS 3548, CLASS B EN 50082-1 and EN 50082-2 (ESD, RF Immunity, EFT etc. - Industrial &

    Commercial). CE compliance marking (safety and EMC for Europe)The 7360 ISAM FX equipment complies with and has been CE-marked in accordance with the following European directives:

    99/05/EC (R&TTE) 73/23/EEC (LVD as amended by directive 93/68) 89/336 (EMC as amended by directive 93/68)

    2.7 Acoustic Noise

    The 7360 ISAM FX equipment meets the acoustic noise requirements defined by ETS 300 753: Equipment Engineering (EE); Acoustic noise emitted by telecommunications equipment, category: telecommunication equipment room.

    2.8 ITU-T K.20/K.45 Compliance

    The 7360 ISAM FX equipment is compliant with the following specifications:

    ITU-T K.20 and ITU-T K.45 specifications for the full unit. In CO deployment, the equipment complies with the enhanced test levels as

    specified in the ITU-T K.20 recommendation when external 420V primary Gas Discharge Tube (GDT) protectors are used on the external LINE interface.

    In remote deployment, the equipment complies with the basic test levels for permanently grounded systems as specified in the ITU-T K.45 recommendation when used in combination with 420V primary protection GDTs on both the POTS and the LINE interface sides.

  • 2 Safety Guidelines for 7360 ISAM FX Equipment

    2-16 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

    2.9 Ecology

    The 7360 ISAM FX equipment complies to:

    Restriction on the use of Hazardous Substances (RoHS) Directive 2002/95/EC Waste from Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC

  • Alcatel-Lucent 7360 ISAM R4.3 July 2011 IN-13HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual

    Index

    F

    FusesPlug-in units, 2-13

    R

    requirementsacoustic noise, 2-15EMC/EMI, 2-15environmental, 2-14safety, 2-2

    S

    safetyinstructions, 1-2requirements, 2-2warning labels, 1-4

    W

    WEEE, 1-5

  • Index

    IN-2 July 2011 Alcatel-Lucent 7360 ISAM R4.3Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA

  • Customer documentation and product support

    Customer documentationhttp://www.alcatel-lucent.com/myaccessProduct manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.

    Technical Supporthttp://www.alcatel-lucent.com/support

    Documentation [email protected]

  • 2011 Alcatel-Lucent. All rights reserved.3HH-10126-AAAA-TCZZA Edition 01 Released

    Safety ManualPrefaceScopeAudienceRequired knowledgeAcronyms and initialismsAssistance and ordering phone numbersSafety informationDocumentsSpecial informationRelease notes

    Contents1 - Conventions1.1 Introduction1.2 Safety Instructions in Customer Documentation1.3 Safety Warning Labels1.4 Waste from Electrical and Electronic Equipment (WEEE)

    2 - Safety Guidelines for 7360 ISAM FX Equipment2.1 Introduction2.2 Safety Requirements2.3 Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment2.4 Fuses on Power Units and Fan Units2.5 Environmental Requirements2.6 EMC/EMI2.7 Acoustic Noise2.8 ITU-T K.20/K.45 Compliance2.9 Ecology

    IndexFRSW