3M Electronics & Energy Business Group
3M Confidential.1 25 February 2014. All Rights Reserved.© 3M
3M Electronics & Energy Business Group
3M™ Novec™ 2-Phase Liquid Immersion Cooling
Kelvin Cabrera – Technical Sales Representative3M Telecommunications, Electronic Market Materials and Electronic [email protected] 1-787-620-4607 / 1-787-553-4518
3M Electronics & Energy Business Group
3M Confidential.2 25 February 2014. All Rights Reserved.© 3M
3M™ Novec™ Engineered Fluids Value Proposition
Safe, Sustainable Chemistry…Combining fast, effective performance with a wide margin of workplace safety and a favorable environmental profile for responsible cost efficient processes and operations .
www.3M.com/Novec
3M Electronics & Energy Business Group
3M Confidential.3 25 February 2014. All Rights Reserved.© 3M
3M™ Novec™ Engineered Fluids
What are they?A family of low global warming solvent materials, based on 3M’s proprietary segregated
hydrofluoroether chemistry
What are they for?Critical industrial applications, including:
―Heat transfer―Precision cleaning ―Lubricant and coating deposition― Solvent Welding―Testing―Fire Suppression and more
www.3M.com/Novec
3M Electronics & Energy Business Group
3M Confidential.4 25 February 2014. All Rights Reserved.© 3M
3M ™ Novec™ Fluids… The ideal combination of properties to meet today’s needs
Environmental ProfileZero ozone depletionVOC ExemptShort atmospheric lifetimeLow global warmingSNAP ApprovedNo HAPS
SafetyNonflammable
low toxicity
High PerformanceDielectric Solvency
CompatibilityStability
Low viscosityWide liquid range
Low water solubility
www.3M.com/Novec
3M Electronics & Energy Business Group
3M Confidential.5 25 February 2014. All Rights Reserved.© 3M
Solvent Evolution – Driven by commitment
CFCs
HCFCs
HFCs
HFEs
CFC -113
HCFC -141b
HCFC -225ca/cb
HCFC -123
HFC -4310
HFC -365
HFC -245
Novec7100
Novec7200
NovecBlends
HAPS 1,1,1,TCA
PERC TCE MeCl
nPB
10 ppm EG
10 ppm EG
Montreal Protocol, US and EU Phase-out
Kyoto Protocol
www.3M.com/Novec
Throughout the years 3M has constantly developed safer and environmentally responsible alternatives for customers solvent needs.
Choosing 3M™Novec™ will allow compliance and adherence to the Montreal and moreover Kyoto Protocol
Health and Safety Focus Environmental Responsibility Focus
3M Electronics & Energy Business Group
3M Confidential.6 25 February 2014. All Rights Reserved.© 3M
Adoption of Novec™ segregated HFEs in place of PFCs or PFPEs leads to 96-99% reduction in greenhouse gas emissions
Adoption of Novec fluids in fire protection leads to greater than a 99 % reduction in GHG emissions.
GWP Value for Different Chemical Classes
0 5000 10000 15000 20000
Global Warming Potential (100 yr ITH)
All PFCs
Nonflammable HFCs
H-Galden HFPEs
3M Novec Fluids
All HFCs
0 5000 10000 15000 20000
Global Warming Potential (100 yr ITH)
All PFCs
Nonflammable HFCs
H-Galden HFPEs
3M Novec Fluids
All HFCs
SF6
www.3M.com/Novec
3M Electronics & Energy Business Group
3M Confidential.7 25 February 2014. All Rights Reserved.© 3M
Immersion Cooling – Past and PresentMore Efficient Than Air, Water or Oil PAST - Has been around since the era of the Cray-2 supercomputer, PAST - Has been considered too advanced and costly for non-military applications until recently. PRESENT - At this day and age, this assumption is simply not true any longer and we cannot afford to
ignore this elegant solution to the high density cooling challenge. PRESENT - Traditional cooling systems that use air, water or oil are complex and costly. Open bath immersion cooling offers:
― A simpler, true alternative solution, saving large amounts of energy, greenhouse emissions and space.
― resolves a number of today’s engineering bottlenecks, allows manufacturers to build better hardware without heat transfer constraints, while also being much cheaper and less complex to build.
It's an open and future proof platform and it will play an important role in solving the energy crises we see in datacenters today.
3M Electronics & Energy Business Group
3M Confidential.8 25 February 2014. All Rights Reserved.© 3M
Immersion Cooling In a two-phase (evaporative) immersion cooled system,
electronic components are submerged into a bath of dielectric heat transfer liquids, which are much better heat conductors than air, water or oil. With their low boiling points (ie. 49°C vs. 100°C in
water), they boil on the surface of the heat generating devices and rising vapor passively takes care of heat transfer. No fans or pumps are required for this process. No need for conventional cooling hardware with better
cooling efficiency. Compared to traditional air or water cooling, this passive
process results in the use of much less energy.
3M Electronics & Energy Business Group
3M Confidential.9 25 February 2014. All Rights Reserved.© 3M
2-Phase Liquid Immersion CoolingOperating Principle
Servers are placed side-by-side in a lidded bath of dielectric fluid.
Devices cause fluid to boil. Rising vapor condenses on a condenser cooled
by facility water. Servers plug into an immersed backplane. Power and IO enter/exit through a conduit that terminates below the liquid level. Servers can be hot-swapped and leave the bath dry. The bath is “semi-open” as it is at atmospheric pressure. Bath breathes through a trap (not shown).
Heat transfer coefficient: Novec + Boiling Enhancement Coating >> Water >> Air
3M Electronics & Energy Business Group
3M Confidential.10 25 February 2014. All Rights Reserved.© 3M
2-Phase Liquid Immersion Cooling for Data CentersDensity, Efficiency, Simplicity
Environmental Sustainability
Speed and Performance
Uptime – Reliability, Availability
Minimizing Operating Expenses
Energy Efficiency
Simplicity and Ease of Use
3M Electronics & Energy Business Group
3M Confidential.11 25 February 2014. All Rights Reserved.© 3M
Immersion CoolingHigher Density Without the restrictions and overhead of traditional cooling
methods offers a much higher density, improved performance and the possibility for applications that would otherwise be impractical.
With a smaller package, lower power consumption and much less supporting infrastructure (ie. no chillers or air conditions), the choice of facilities becomes much less restrictive.
Eliminates the Heat Transfer Overhead for Product Designers
Our passive immersion cooled systems free the designer from all the overhead of a heat transfer system.
For developers, time to market can be greatly improved, Engineers focus on building the application instead of finding
ways to get the heat out.
Future-Proof (future hardware works without any changes) In an immersion cooled system, new hardware does not require any
resources for the heat transfer process. In other words, your immersion cooling enclosure will work with all your future hardware too. Out with the old, in with the new.
Non-proprietary - Universal Design Immersion cooling systems don't lock customers in to one
technology. What goes in enclosures and what connects to them is completely up to the end-user.
This holds true for server level hardware (inside the tank) and for facility level infrastructure.
3M Electronics & Energy Business Group
3M Confidential.12 25 February 2014. All Rights Reserved.© 3M
Immersion CoolingImproved Performance and Reliability Hardware benefits from lower junction temperatures
and improved performance, no temperature swings or hot spots, and generally runs more reliable.
No unnecessary parts to build or service since the cooling system is passive and not attached to the hardware
Extremely Clean2-phase immersion cooling system has positive side effects on both, the device and facility level: Massive air flow, dust and noise are eliminated from the
facility. Having no fans, bulky heatsinks or air channels on the
hardware level results in a very clean and elegant design.
Board removal (swap) will come out dry, due to low temperature evaporation.
Zero Ozone Depletion Potential & Inherent Fire Protection
3M™ Novec™ Engineered Fluids have an excellent environmental, health and safety profile.
Novec fluid does not deplete ozone (zero ozone depletion potential) and has a very low global warming potential.
It is non-toxic and non-flammable. Because of its low global warming potential, Novec is used in
gas fire extinguishing systems by companies such as IBM in data centers worldwide.
Non-proprietary - Universal Design Immersion cooling systems don't lock customers in to one
technology. What goes in enclosures and what connects to them is completely up to the end-user.
This holds true for server level hardware (inside the tank) and for facility level infrastructure.
3M Electronics & Energy Business Group
3M Confidential.13 25 February 2014. All Rights Reserved.© 3M
Immersion CoolingAdvantages of Immersion Cooling: Higher efficiency and energy savings (>90% electricity savings) Reduced capital and operational expenses Improved performance Higher density Improved hardware reliability Faster time to market Fits any form, size or shape of electronics components and boards Non-flammable, inherent fire protection Works in confined spaces and extreme environments (hot & humid etc). Reduced environmental impact
3M Electronics & Energy Business Group
3M Confidential.14 25 February 2014. All Rights Reserved.© 3M
Power used for cooling <1% of IT power *
Immersion-2Real cost of ownership data are being generated during the building and start-up of Immersion-2. Built by Allied Control for a client in hot humid Hong Kong, the 500kW system started up with a PUE<1.01.
Conceptual Drawing of Immersion-2
Traditional Air Cooled DC• 4 kW/rack • 35 racks = 140 kW• 1 SQM per kW
Immersion-2•24 kW/rack
Immersion-2•75 kW/rack
When compared with a conventional air cooled data center, the space saving achievable with the Immersion-2 racks is dramatic, particularly if the racks are populated at their 75kW capability. Potential savings in real estate costs and annual
electricity expenditure for 10MW facility in Singapore
3M Electronics & Energy Business Group
3M Confidential.15 25 February 2014. All Rights Reserved.© 3M
Novec 2-Phase Immersion Cooling Applications
Product Description Key Differentiators & ValueOpen Bath Immersion (OBI) Cooling Passive, 2-phase (evaporative) cooling technique that
involves immersing servers in a bath of Novec engineered fluids, non-electrically conductive fluids
• Potential to enable exascale computing• Potential to decrease power usage compared to traditional air-
cooling• Reduced need for air cooling infrastructure and liquid-cooling
pumps• Provides inherent fire protection for servers• Novec fluids have outstanding environmental profile
Convection Cooling Iceotope solution – Server is completely immersed in sealed bath of Novec which passively transfers heat away to a heat exchanger (with water coolant)
Other convection solutions are possible due to Novec’s highly efficient heat transfer properties
• Iceotope solution:• Reduces cooling costs by 97%, IT power load by 20%, and
overall infrastructure costs by 50%• Won GEIT (Green Enterprise IT) award for facility product
deployment in conjunction with Iceotope• Novec - >1000x more effective at carrying heat than air• Novec fluids have outstanding environmental profile
3M’s Liquid Immersion Cooling using Novec Engineered Fluids provides more efficient cooling than traditional air cooling, especially for high performance servers, and also provides inherent fire protection for servers.
3M Electronics & Energy Business Group
3M Confidential.16 25 February 2014. All Rights Reserved.© 3M
3M Novec Liquid Immersion Cooling: Key InfoSupporting Material – Product Brochure, Cases, White Papers, Webinars
Type Description Link DateWebsite Immersion cooling page on data center website Link n/a
YouTube video Open Bath Immersion Cooling Video link April 2013
White Paper The Merits of Open Bath Immersion Cooling of Datacom Equipment
Link on IEEE 2010
Article Playing it cool; New immersion cooling process could lead to 90% reductions in data center energy usage for cooling
Link to article May 2012
Press Releases Uptime’s Green Enterprise IT Award GEIT Award press release Spring 2013
Iceotope Technology partner http://www.iceotope.com/ n/a
Allied Control Technology partner http://www.allied-control.com/ n/a
Article Data Center Knowledge - 3M Demos New Immersion Cooling Technique
Link to Data Center Knowledge article Fall 2012
3M Electronics & Energy Business Group
3M Confidential.17 25 February 2014. All Rights Reserved.© 3M
3M’s Data Center Offering – Portfolio Overview
3M Electronics & Energy Business Group
3M Confidential.18 25 February 2014. All Rights Reserved.© 3M
For additional information, visit us online at:
www.3M.com/Novecwww.youtube.com/3MNovec
Product descriptions and propertiesApplication descriptions
Technical papersCase Studies
3M Electronics & Energy Business Group
3M Confidential.19 25 February 2014. All Rights Reserved.© 3M
ThankYou!