A R C H I T E C T U R A L D E T A I L F I L E 7-1 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Flexiframe®, Arch, Springline™ and Enhancement WindowsBasic Unit Details Flexiframe® Basic Unit ................................................... 7-26 Arch / Custom Arch Basic Unit ...................................... 7-26 Springline™ Basic Unit ................................................... 7-27 Springline™ Flanker Basic Unit ....................................... 7-27 Enhancement Full Chord Basic Unit ............................... 7-28 Enhancement Gothic Basic Unit .................................... 7-28 Enhancement Monumental Quarter Round Basic Unit .... 7-29 Enhancement Monumental Full Round Basic Unit .......... 7-29 Enhancement Octagon Basic Unit .................................. 7-29Design Parameters for Custom Arch Windows ....................... 7-30Options / Accessories Andersen® Grilles ........................................................... 7-32 Extension Jambs ........................................................... 7-34Trim Options and Applications - Arch Windows Transom Joining of Equal Leg Arch ................................ 7-35 Arch Combination ......................................................... 7-35 Arch Palladian / Casement Combination ....................... 7-35 Transom Joining of Partial Chord Arch ........................... 7-36 Extension Jamb Trim-out ................................................ 7-36Trim Options and Applications - Springline™ Windows Transition Piece / Key Block / Plinth Block .................... 7-37 Key Block / Key Component .......................................... 7-38 Transition Piece ............................................................. 7-39Trim Options Plinth Block ................................................................... 7-40 Interior Casing ............................................................... 7-41Joining Details ..................................................................... 7-42Anchoring Methods .............................................................. 7-43Suggested Product Applications ........................................... 7-44
ContentsCircle Top™, Elliptical, Circle and Oval WindowsBasic Unit Details Circle Top™ and Quarter Round Basic Unit ................7-2 Elliptical Basic Unit ...................................................7-3 Circle and Oval Basic Unit .........................................7-3Options / Accessories Andersen® Grilles .......................................................7-4 Extension Jambs .......................................................7-6Trim Options and Applications—Circle and Oval Windows Transition Piece / Key Block ......................................7-8 Key Block/Key Component ........................................7-9 Transition Piece ...................................................... 7-10Trim Options and Applications—Circle Top & Elliptical Windows Plinth Blocks .......................................................... 7-11 Interior Casing ........................................................ 7-12Joining Details .............................................................. 7-13Anchoring Methods ....................................................... 7-17Suggested Product Applications .................................... 7-18
Compatible sizes and jamb configurations facilitate joining Circle Top™ and elliptical units with other Andersen® windows and doors to create combinations.
• Low maintenance exteriors with natural wood interiors
• Excellent for creating window combinations
• Inside arch casings simplify interior trim application
Standard sizes are available in hundreds of sizes and shapes. Flexiframe® and custom arch windows allow you to create custom windows.
• Low maintenance exteriors with natural wood interiors
• Create large window combinations
• Custom design capability
Circle Top™, Quarter Round & Elliptical Windows
Circle & Oval Windows Flexiframe® Windows Custom Arch , Springline™ & Enhancement Windows
A R C H I T E C T U R A L D E T A I L F I L E7-2 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Basic Unit Details
Vertical SectionCircle Top
Vertical Section
Circle Top™ and Quarter Round Basic Unit(for casement and awning sizes)Scale 3" = 1'-0" (1:4)
Circle Top™ Basic Unit(for double-hung sizes)Scale 3" = 1'-0" (1:4)
Vertical SectionQuarter Round
1-5/16" (33)
2-1/4" (57)
2-1/4" (57)
2-7/8" (73)
1-1/8" (29)
1-1/8" (29)
1" (25)
1-1/4" (31)
Head
Sill
4-1/2" (116)1-5/16" (33)
2-3/8" (60)
2-5/8" (67)
13/16" (21)
7/16" (11)
1-3/8" (35)
1-1/16" (27)
7/16" (11)
5/16" (8)9/16" (14)
Head
Sill
Head
Sill
2-1/4" (57)
2-1/8" (54)
1-5/16" (33) 2-7/8" (73)
1-1/8" (29)
1-1/8" (29)
1-1/8" (29)
1" (25)
A R C H I T E C T U R A L D E T A I L F I L E 7-3 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Basic Unit Details
Elliptical Basic UnitScale 3" = 1'-0" (1:4)
Circle and Oval Basic UnitScale 3" = 1'-0" (1:4)
4-1/2" (116)1-5/16" (33)
9/16" (14)
1" (25)
15/16" (24)
2-5/16" (59)
7/8" (22)
1-1/8" (29)
5/16" (8)
2-1/2" (64)
Head
Sill
Vertical Section
Vertical Section
2-7/8" (73)1-5/16" (33)
1-1/8" (29)
1-1/8" (29)
2-1/4" (57)
1-1/8" (29)
1-1/8" (29)2-1/4" (57)
Optional Andersen®
key block
Optional Andersen®
key component(circle style shown)
Standard Andersen®
transition piece stop(circle style shown)
Optional Andersen®
transition piece extension jamb
Optional Andersen®
extension jambs
Optional Andersen®
interior casing
Optional Andersen® transition piece casing
Head
Sill
A R C H I T E C T U R A L D E T A I L F I L E7-4 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Options / Accessories
Andersen® Divided Light Grilles
White
Sandtone
Terratone®
Forest Green
3/4"
7/8"
1-1/8"
2-1/4"
With Spacer
Without Spacer
Maple
Oak
Prefinished
Pine
Colonial
Modified Colonial
Modified Col W/Check Rail
Prairie A
Short Fractional
Short Fractional W/Check Rail
Tall Fractional
Tall Fractional W/Check Rail
Victorian
Renaissance
Sunburst
Specified Equal Light
Custom
HP/HP Tempered
HP Sun/HP Sun Temp
3/8" Low-E/Temp
Single-Pane Impact
Available now
Available only with 3/8" glass through the Andersen Divided Light program
Please check with Andersen for availability
Andersen®400 Series Windows
Gla
ss
Patt
erns
In
terio
r Ty
pe
Wid
th
Exte
rior C
olor
Andersen®400 Series Doors
Case
men
t & A
wnin
g
Case
men
t Pic
ture
Win
dow
Glid
ing
Win
dow
Woo
dwrig
ht®
Doub
le-H
ung
& Tr
anso
m
Woo
dwrig
ht®
Pict
ure
Win
dow
Woo
dwrig
ht®
Arch
top
& U
nequ
al L
eg A
rcht
op
Woo
dwrig
ht®
Sprin
glin
e™ S
ingl
e-Hu
ng
Tilt-
Was
h Do
uble
-Hun
g &
Tran
som
Tilt-
Was
h Pi
ctur
e W
indo
w
Circ
le To
p™ &
Qua
rter R
ound
Arch
Sprin
glin
e™
Flex
ifram
e®
Ellip
tical
Circ
le &
Ova
l
Goth
ic
200
Serie
s Na
rrolin
e® D
oubl
e-Hu
ng &
Tran
som
Fren
chwo
od®
Glid
ing
Fren
chwo
od®
Hing
ed In
swin
g
Fren
chwo
od®
Hing
ed O
utsw
ing
Fren
chwo
od®
Patio
Doo
r Sid
elig
hts &
Tran
som
s
A R C H I T E C T U R A L D E T A I L F I L E 7-5 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Andersen® Divided Light GrillePermanent ExteriorPermanent Interiorwith Spacer
Andersen® Divided Light GrillePermanent ExteriorPermanent Interior
Andersen® Divided Light GrillePermanent ExteriorRemovable Interior
RemovableInterior
Andersen® Finelight™Grilles-Between-the-Glass
3/32"
5/16"
5/16" 7/16"
7/16"
45˚
2-1/4"
53˚3/8"3/8"3/8" 53˚
7/8"
45˚45˚
3/4"
53˚ 35˚
1-1/8"
35˚
1/2"
1-13/16"
5/16" 7/16"
2-1/4"7/8"3/4" 1-1/8"
1/2"
7/8"3/4" 1-1/8"
1/2" 1-13/16"
5/16"5/16"5/16"
3/16"1/8" 5/16"
1/2"
1/8"
1/2" 1/2" 1/2" 1/2"
Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.
Permanent Interior Wood Grille Profiles (chamfer profile).The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.
Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile).400 Series Woodwright® double-hung windows only.
Permanent Full Divided Light Grille spacer location.
Andersen® Finelight™ Grilles-Between-the-Glass.
7/16"
7/8"3/4" 1-1/8"
3/8"
3/4"
1/2"
1"
Options / Accessories
Grille Profiles • Scale = Full • Dimensions include thickness of tape.
400 Series Grille Options
A R C H I T E C T U R A L D E T A I L F I L E7-6 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Options / Accessories
Extension Jambs for Circle Top™ (casement/awning size), Circle and Oval WindowsScale 3" = 1'-0" (1:4)
Extension jambs available for 4-9/16" (116), 5-1/4" (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 6-9/16" extension jamb is predrilled for easy application.
Horizontal Section
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
Unit Dim. Width
Rough OpeningWidth
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)
Face
: 4-9
/32"
(109
)
Face
: 3-2
3/32
" (9
5)
Face: 1-23/32" (44)
2-13
/32"
(61)
3/4" (19) at curve11/16" (17) at sill
1/4" (6)
Extension Jambs for Circle Top™ (double-hung size) WindowsScale 3" = 1'-0" (1:4)
Horizontal Section
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
Optional Andersen®arched casing
Rough OpeningWidth
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)2-
9/16
" (6
5)
Face
: 2"
(51)
Face
: 11/
16"
(17)
1/4" (6)
3/4" (19) at curve11/16" (17) at sill
A R C H I T E C T U R A L D E T A I L F I L E 7-7 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Options / Accessories
Extension Jambs for Elliptical UnitScale 3" = 1'-0" (1:4)
Horizontal Section
Extension Jambs for Elliptical Unit for Frenchwood® Gliding DoorScale 3" = 1'-0" (1:4)
Horizontal Section
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
1/4" (6)Unit Dim. Width
Rough OpeningWidth
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)Fa
ce: 2
-9/1
6" (6
5)
Face
: 2"
(51)
Face
: 11/
16"
(17)
5/8" (16) at curve11/16" (17) at sill
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
1/4" (6)Unit Dim. Width
Rough OpeningWidth
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)Fa
ce: 2
-9/1
6" (6
5)
Face
: 2"
(51)
Face
: 11/
16"
(17)
5/8" (16) at curve11/16" (17) at sill
Optional Andersen® inside filler strip for transom joining over Andersen Frenchwood® gliding door
Extension jambs available for 4-9/16" (116), 5-1/4" (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification.
A R C H I T E C T U R A L D E T A I L F I L E7-8 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options and Applications—Circle and Oval
Transition Piece / Key Block
Optional Andersen®
key blockOptional Andersen®
key component(circle style shown)
Transition piece
Optional Andersen®
transition piecearch casing
Optional Andersen® transition pieceextension jamb
Standard Andersen® transition piece stop (circle style shown)
Circle(Oval similar)
A R C H I T E C T U R A L D E T A I L F I L E 7-9 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s5-3/8" (137mm)
3-3/8" (86mm)
2" (51mm)
3-3/8" (86mm)
1-1/2" (38mm)
1" (25mm)3/8" (10mm)
3/8" (10mm)
4-7/
8" (1
24m
m)
4-1/
8" (1
05m
m)
7/8" (22mm)
1" (25mm) 3-15/16" (100mm) @ 4-9/16" (116mm) wall
4-7/16" (113mm) @ 5-1/4" (133mm) wall
5-15/16" (151mm) @ 6-9/16" (167mm) wall
6-15/16" (176mm) @ 7-1/8" (181mm) wall
Key block
Key component - circle style shown(4 sizes available or cut to fit wall depth)
Key block
Key component - oval style shown
Trim Options and Applications—Circle and Oval
Key Block/Key ComponentScale: HalfAvailable in maple or oak.
A R C H I T E C T U R A L D E T A I L F I L E7-10 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options and Applications—Circle and Oval
Transition PieceAvailable in maple or oak.
3/8" (10)
1" (25)
2-11/16" (68)
1-5/8" (41) for 3-1/2" (89) casing
1-7/16" (37) for 2-1/4" (57) and 2-1/2" (64) casing
Standard Andersen® transition piece casing
Optional Andersen®
transition piece extension jamb
Standard Andersen®
transition piece stop(circle style shown)
4-1/8" (105) for 3-1/2" (89) casing
3" (76) for 2-1/4" (57) and 2-1/2" (64) casing
1-1/2" (38) for 3-1/2" (89) casing
1-3/16" (30) for 2-1/4" (57) and 2-1/2" (64) casing
9/16" (14)
Cut to fit -36" (914) lengths available
A R C H I T E C T U R A L D E T A I L F I L E 7-11 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options and Applications—Circle Top™ and Elliptical Windows
Plinth BlocksScale: HalfAvailable in maple or oak.
For use with 2-1/4" or 2-1/2" (57mm or 64mm) casing.
2-7/8" (73mm)
1-1/8" R
2-7/8" (73mm)7/8" (22mm)
For use with 3-1/2" (89mm) casing.
3-7/8" (98mm) 1-1/2" R
3-7/8" (98mm)
7/8" (22mm)
Optional Andersen®
interior arch casing(Colonial or Ranch styles)
Optional Andersen® transom casing
Optional Andersen® plinth blocks
Interior trim by others
A R C H I T E C T U R A L D E T A I L F I L E7-12 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Circle Top™ Windows (casement/awning type),Circle and Oval
Circle Top™ Windows (double-hung type)
Elliptical
5/32" (4mm) typical
Ranch Style - WM 3242-1/4" x 11/16" (57mm x 17mm)
Available in select hardwoods.
Ranch Style - WM 3152-1/2" x 11/16" (64mm x 17mm)
Available in select hardwoods.
Colonial Style - WM 3662-1/4" x 11/16" (57mm x 17mm)
Available in select hardwoods.
Colonial Style - WM 3512-1/2" x 11/16" (64mm x 17mm)
Available in select hardwoods.
Colonial Style - WM 4443-1/2" x 11/16" (89mm x 17mm)
Available in select hardwoods..
5/32" (4mm) typical
5/32" (4mm) typical
Trim Options and Applications—Circle Top™ and Elliptical Windows
Interior CasingScale: FullAvailable for all cur ved portions of windows.
A R C H I T E C T U R A L D E T A I L F I L E 7-13 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Circle Top™ Window over CasementScale 3" = 1'-0" (1:4)
Non-Reinforced Wood Transom
Joining Details—Circle Top™, Elliptical, Circle and Oval Windows
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Optional Andersen®
2-5/8" (67) casing
Casement Unit
Circle Top™ Unit (for Casement/Awning)
Optional Andersen®
wood joining material
Sealant and optional Andersen® exterior trim strip
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Optional Andersen® 2-5/8" (67)casing for steel
Casement Unit
Inside stop
Inside stop
Optional Andersen®
steel reinforced join
Location block
Circle Top™ Unit (for Casement/ Awning)
Sealant and optional Andersen® exterior trim strip
Steel Reinforced Narrow Transom Steel Reinforced Narrow Transom
For narrow wood, narrow aluminum and narrow steel joining materials:
Overall unit dimension height = the sum of the individual unit heights + 1/8" (3mm)
Overall rough opening height = the sum of the individual unit heights + 5/8" (16mm)
Circle Top™ Window over AwningScale 3" = 1'-0" (1:4)For narrow wood, narrow aluminum and narrow steel joining materials:
Overall unit dimension height = the sum of the individual unit heights + 1/8" (3mm)
Overall rough opening height = the sum of the individual unit heights + 5/8" (16mm)
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Optional Andersen® 2-5/8" (67) casing
Awning Unit
Circle Top™ Unit (for Casement /Awning)
Optional Andersen® wood joining material
Sealant and optional Andersen® exterior trim strip
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Awning Unit
Circle Top™ Unit (for Casement/ Awning)
Optional Andersen® 2-5/8" (73) casing
Inside stop
Inside stop
Location block
Optional Andersen®
steel reinforced join
Sealant and optional Andersen® exterior trim strip
Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
Non-Reinforced Wood Transom
A R C H I T E C T U R A L D E T A I L F I L E7-14 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Optional Andersen®
2" (51) modifiedcasing
Tilt Wash Unit
Circle Top™ Unit (for double-hung)
3/16" (5) shimby others
Optional Andersen®
steel reinforced join
Optional Andersen® trim strip set incontinuousbead of sealanteach side
Unit
Dim
ensi
onUn
itDim
ensi
onm
inus
1/2
"
5/16" (8)
Double-hungscrew locationsno. 10 x 2-1/4" screw
Picture/transomscrew locationsNo. 10 x 2-1/4" screw
Optional Andersen® steel reinforced join
Optional Andersen® 1-1/2" (38) casing(2" modified)
Narroline® Unit
Circle Top™ Unit (for double-hung)
Optional Andersen® trimstrip set incontinuous bead of sealant each side
Circle Top™ Window over Narroline® Double-Hung Window
Non-Reinforced Transom
Joining Details—Circle Top™, Elliptical, Circle and Oval Windows
Steel Reinforced TransomFor narrow wood joining material: Overall unit dimension height = the sum of the indivvidual unit heights – 3/8" (10mm)Overall rough opening height = the sum of the individual unit heights – 3/8" (10mm)
Scale 3" = 1'-0" (1:4)
Narroline® Unit
Circle Top™ Unit (for double-hung)
Unit
Dim
ensi
onUn
it Di
men
sion
min
us 1
/2"
1/8" (3)
Optional Andersen®
trim strip set incontinuousbead of sealanteach side
Andersen® plinth blockbeyond
Optional Andersen® 1-1/2" (38) casing
For narrow steel joining material: Overall unit dimension height = the sum of the individual unit heights – 3/16" (5mm)Overall rough opening height = the sum of the individual unit heights – 3/16" (5mm)
Circle Top™ Window over T ilt-Wash Double-Hung Window
Non-Reinforced Transom Steel Reinforced TransomFor narrow wood joining material: Overall unit dimension height = the sum of the individual unit heights + 0" (0mm)Overall rough opening height = the sum of the individual unit heights + 0" (0mm)
Scale 3" = 1'-0" (1:4)
For narrow steel joining material: Overall unit dimension height = the sum of the individual unit heights + 0" (0mm)Overall rough opening height = the sum of the individual unit heights + 0" (0mm)
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Optional headfiller piece or3/8" (9) shimby others
Optional Andersen®
1-1/2" (38) casing
Tilt Wash Unit
Circle Top™ Unit (for double-hung)
Optional Andersen® trim strip set incontinuousbead of sealanteach side
Circle Top™ Window over Circle Top™ Window(casement/awning type) Scale 3" = 1'-0" (1:4)
Non-Reinforced Wood Joining
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
Optional Andersen® 2-7/8" (73) wood casing
Optional Andersen®
wood joining material
Optional Andersen®
trim strip set incontinuousbead of sealanteach sideCircle Top™ Unit
Circle Top™ Unit
Circle Top™ Window over Circle Top™ Window(double-hung type) Scale 3" = 1'-0" (1:4)
Unit
Dim
ensi
onUn
itDim
ensi
on
1/8" (3)
Andersen® plinth block beyond
Wood blockingby others
Optional Andersen® 1-1/2" (38) insidetransom casing
Circle Top™ Unit
Circle Top™ Unit
Optional Andersen® trim strip set incontinuous bead of sealant each side
Non-Reinforced Joining
A R C H I T E C T U R A L D E T A I L F I L E 7-15 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Elliptical over Frenchwood® Hinged Patio Door
Non-Reinforced Transom Steel Reinforced TransomFor narrow wood joining material:
Overall unit dimension height = the sum of the individual unit heights + 1/8" (3mm)
Overall rough opening height = the sum of the individual unit heights + 5/8" (16mm)
Scale 3" = 1'-0" (1:4)
For narrow steel joining material:
Overall unit dimension height = the sum of the individual unit heights + 1/8" (3mm)
Overall rough opening height = the sum of the individual unit heights + 5/8" (16mm)
Joining Details—Circle Top™, Elliptical, Circle and Oval Windows
Unit
Dim
ensi
on
1/8" (3)
Unit
Dim
ensi
on
2-5/8" (57)
Andersen® plinth block beyond
Optional Andersen®
joining strip
Optional Andersen® trim strip set incontinuousbead of sealanteach side
Screw throughhead jamb of door into sill of elliptical unitwith screws providedin joining kit
Optional Andersen® 2-3/8" (60) casing
Frenchwood® Hinged Patio Door Unit
Elliptical Unit
Unit
Dim
ensi
on
1/8" (3)
Unit
Dim
ensi
on
2-7/8" (73)
Optional Andersen® steel reinforced join
Sealantand optional Andersen®
exterior trim strip
Optional Andersen® 2-3/8" (60) casing
Plywood shimby others
Frenchwood® Hinged Patio Door Unit
Elliptical Unit
Elliptical over Frenchwood® Gliding Patio Door
Non-Reinforced Transom Steel Reinforced TransomFor narrow wood joining material:
Overall unit dimension height = the sum of the individual unit heights + 3/8" (10mm)
Overall rough opening height = the sum of the individual unit heights + 7/8" (22mm)
Scale 3" = 1'-0" (1:4)
For narrow steel joining material:
Overall unit dimension height = the sum of the individual unit heights + 3/8" (10mm)
Overall rough opening height = the sum of the individual unit heights + 7/8" (22mm)
Unit
Dim
ensi
on
3/8" (10)
Unit
Dim
ensi
on
Andersen® plinth block beyond
Optional Andersen®
joining block
Sealant andoptional Andersen®
exterior trim strip
Optional Andersen® 2-5/8" (67) wood transom casing
Elliptical Unit
Frenchwood® Gliding Patio Door Unit
Head flange(trimmed)
Unit
Dim
ensi
on
3/8" (10)
Unit
Dim
ensi
on
1/2" x 3-1/2"full length filler stripby others
Optional Andersen® 2-5/8" (67) casing
Head flange(trimmed)
Elliptical Unit
Frenchwood® Gliding Patio Door Unit
Optional Andersen®
steel reinforced join
Sealant and optional Andersen® exterior trim strip
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E7-16 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Elliptical over Narroline® Double-Hung Window
Non-Reinforced Transom Steel Reinforced Transom
For narrow wood joining material:
Overall unit dimension height = the sum of the individual unit heights – 3/8" (10mm)
Overall rough opening height = the sum of the individual unit heights – 3/8" (10mm)
Scale 3" = 1'-0" (1:4)
For narrow steel joining material:
Overall unit dimension height = the sum of the individual unit heights – 3/16" (5mm)
Overall rough opening height = the sum of the individual unit heights – 3/16" (5mm)
Joining Details—Circle Top™, Elliptical, Circle and Oval Windows
Elliptical over T ilt-Wash Double-Hung Window
Non-Reinforced Transom Steel Reinforced Transom
For narrow wood joining material:
Overall unit dimension height = the sum of the individual unit heights + 0" (0mm)
Overall rough opening height = the sum of the individual unit heights + 0" (0mm)
Scale 3" = 1'-0" (1:4)
For narrow steel joining material:
Overall unit dimension height = the sum of the individual unit heights + 0" (0mm)
Overall rough opening height = the sum of the individual unit heights + 0" (0mm)
Unit
Dim
ensi
onUn
itDim
ensi
onm
inus
1/2
"
5/16" (8)
Optional Andersen®
steel reinforced join
Optional Andersen®
2" (51) modified casing
Narroline® Unit
Elliptical Unit
Optional Andersen®
trim strip set incontinuousbead of sealanteach side
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)Optional Andersen®
2" (51) modifiedwood casing
Tilt-Wash Unit
Elliptical Unit
3/16" (5) shimby others
Optional Andersen®
steel reinforced join
Optional Andersen®
trim strip set incontinuous bead of sealant each side
Unit
Dim
ensi
onUn
it Di
men
sion
1/8" (3)
3/8" (9) shimby others
Optional Andersen®
2" (51)wood casing
Tilt-Wash Unit
Elliptical Unit
Optional Andersen®
trim strip set incontinuousbead of sealanteach side
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
Unit
Dim
ensi
onUn
itDim
ensi
onm
inus
1/2
"
1/8" (3)
Andersen® plinth block beyond
Optional Andersen®
2" (51) insidetransom casing
Narroline® Unit
Elliptical Unit
Optional Andersen®
trim strip set incontinuousbead of sealanteach side
A R C H I T E C T U R A L D E T A I L F I L E 7-17 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Window is secured in the opening by using threaded fasteners through the installation flange.
Anchoring Methods—Circle Top™, Elliptical, Circle and Oval Windows
Installation FlangeScale 3" = 1'-0" (1:4)
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Jamb Clips Scale 3" = 1'-0" (1:4)
Window unit is secured in the opening by securing a side jamb clip to the unit, pre-drilling into masonry, inserting expansion sleeve, and driving flat head screw. Vinly flange to be cut, or removed, as required.
Installation flange
Exterior sheathing
Horizontal SectionCircle Top™ (double-hung)
or Elliptical Window
Installation flange
Exterior sheathing
Expansion sleevewith flat head screw(furnished by others)
Horizontal SectionCircle Top™ (casement/awning),
Circle or Oval Window
Horizontal SectionCircle Top™ (casement/awning),
Circle or Oval Window
Horizontal SectionCircle Top™ (double-hung)
or Elliptical Window
Countersinkand plug
Wood buck
Jamb clip flat
Optional Andersen® auxiliary casingMake sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
• First secure jamb clip to back side of window unit jamb(s)
• Apply 1' from corners of head jamb, sill and side jambs
• Space jamb clips evenly (maximum distance apart 32" on center)
• Jamb clip lateral design load capacity: maximum 200 lb.
Window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend jamb clips to secure unit fit in opening. Installation flange can be cut as required to accommodate jamb clips.
APPLICATION:
A R C H I T E C T U R A L D E T A I L F I L E7-18 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle Top™ for Casement / Awning Windows
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Installation flange all around
Optional Andersen®
archedextensionjamb
Optional Andersen®
extensionjambs
Optional Andersen®
3/4" x 5-1/2"(19 x 140)vinyl trimboard
Installationflangeall around
Andersen®
casement unit
Optional Andersen®
arch casing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood joining material
Removeinstallationflange allaround
Andersen®
casement unit
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood joining material
Andersen®
casement unit
Installationflange athead
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 7-19 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle Top™ for Casement / Awning Windows
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Optional Andersen®
auxiliarycasing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood joining material
Andersen®
casement unit
Optional Andersen®
auxiliarycasing
Installation flange at head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Optional Andersen®
plinth blocks
Head
Transom Optional Andersen®
inside transom casing
Optional Andersen®
interior arch casing &extension jambs
Optional Andersen® vinyl trim strip set in sealant and wood joining material
Andersen®
casement unit
Optional Andersen®
vinyl trim board
Existingframe wall
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood joining material
Andersen®
casement unit
Optional Andersen®
plinth blocks
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Optional Andersen®
archedextensionjamb
Transom Optional Andersen®
inside transom casing & plinth blocks
Optional Andersen® vinyl trim strip set in sealant and wood joining material Andersen®casement unit
Existing masonry wall
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersen®
rigid vinylchannel
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Optional Andersen®
archedextensionjamb
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E7-20 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle Top™ for Double-Hung Windows
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Transom
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Installation flange all around
Optional Andersen®
3/4" x 5-1/2"(19 x 140)vinyl trimboard
Installationflangeall around
Andersen®
Woodwright® unit
Optional Andersen®
arch casing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood filler
Andersen®
Woodwright® unit
Removeinstallationflange all around
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood filler
Andersen®
Woodwright® unit
Installationflange athead
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 7-21 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle Top™ for Double-Hung Windows
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Optional Andersen®
auxiliarycasing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood filler
Andersen®
Woodwright® unit
Optional Andersen®
auxiliarycasing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casing& plinth block
Optional Andersen®
interior arch casing
Optional Andersen® vinyl trim strip set in sealant and wood filler Andersen® Woodwright® unit
Optional Andersen®
vinyl trim board
Existingframe wall
TransomOptional Andersen® vinyl trim strip set in sealant and wood filler
Andersen®
Woodwright® double-hungunit
Optional Andersen®
inside transom casing & plinth blocks
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Transom Optional Andersen®
inside transom casing & plinth blocks
Optional Andersen® vinyl trim strip set in sealant and wood filler Andersen® Woodwright® unit
Existing masonry wall
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersen®
rigid vinylchannel
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Optional Andersen®
arched extensionjamb trimmed to fit
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E7-22 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Elliptical Windows
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3/8" (10)
Installationflange
Optional Andersen® wood joining block
Optional Andersen®
head flashing
Optional Andersen®
vinyl trim setin sealant withbacker rod
Optional Andersen® inside transom casing and plinth block beyond
Andersen®
gliding patio door
Optional Andersen®
arch casing
Transom
Head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
wood joining block & casingOptional Andersen® vinyl trim set in sealantwith backer rod Andersen® Gliding Patio Door
Removeinstallationflange all around
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom
Installationflange allaround
Membrane flashing over installationflange(by others)
Optional Andersen®
wood joining block & casingOptional Andersen® vinyl trim set in sealantwith backer rod Andersen® Gliding Patio Door
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 7-23 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Elliptical Windows
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Head
Optional Andersen®
auxiliarycasing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Transom
Optional Andersen®
wood joining block & casing
Optional Andersen® vinyl trim set in sealantwith backer rod
Andersen®
Gliding Patio Door
Head
Optional Andersen®
auxiliarycasing
Installationflange at head& jambs
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Transom
Optional Andersen®
inside casing & plinth block
Optional Andersen®
arch casing
Optional Andersen® vinyl trim set in sealantwith backer rod
Andersen®
Gliding Patio Door
Optional Andersen®
vinyl trim board
Existingframe wall
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3/8" (10)
Optional Andersen® wood joining block
Optional Andersen®
head flashing
Optional Andersen®
vinyl trim setin sealant withbacker rod
Optional Andersen® inside transom casing and plinth block beyond
Andersen®
gliding patio door Transom
Head
Existing masonry wall
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersen®
rigid vinylchannel
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3/8" (10)
Optional Andersen® wood joining block
Optional Andersen®
head flashing
Optional Andersen® inside transom casing and plinth block beyond
Optional Andersen® extension jambtrimmed to fit
Andersen®
gliding patio door Transom
Head
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E7-24 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle and Oval Windows
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Head
Sill
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Optional Andersen®key block
Optional Andersenextension jambs andtransition pieces
Optional Anderseninterior arch casing and transition pieces
Standard Andersentransition blockfor circle unit
Extend and attachvapor barrier to unitframe (by others)
Nailingflange allaround
Head
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Standard Andersentransition blockfor circle unit
1/2" (13)*minimum
Extend and attachvapor barrier to unitframe (by others)
Remove installation flangeat head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Installationflange allaround
Head
Sill
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 7-25 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle and Oval Windows
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Sill
Optional Andersen®
auxiliarycasing
Installationflangeall around
Head
Optional Andersen®
auxiliarycasing
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Removeinstallationflangeat sill
Optional Andersen®
interior arch casing & extension jambs
Head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Optional Andersen®
vinyl trim board
Existingframe wall
Installationflangeall around Optional Andersen
extension jambs
Sill
Standard Andersentransition blockfor circle unit
Head
Optional Andersen extension jambs
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Existing masonry wall
Installationflange all around
Sill
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersen®
rigid vinylchannel
Standard Andersentransition blockfor circle unit
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E7-26 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Basic Unit Details
Horizontal and Vertical Section
Vertical Section
Flexiframe® Basic UnitScale 3" = 1'-0" (1:4)
Unit Dimension Width
Rough Opening Width
1/4" (6)
2-3/8" (60)
1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)
Wood frame
Glass fiberreinforcedmaterial
Reversible or removable installation flange
Jamb Jamb
Arch / Custom Arch Basic UnitScale 3" = 1'-0" (1:4)
V
V
H
H
Unit Dimension Width
Rough Opening Width
1/4" (6)
2-3/8" (60)
1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)
Wood frame
Glass fiberreinforcedmaterial
Reversible or removable installation flange
Jamb Jamb
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1/4" (6)
1/4" (6)
2-3/8" (60)
Arch laminated maple
Flexible leg
Rigid notched leg
Wood frame
Glass fiber reinforced material
Clad aluminum
Head
SillReversible or removable installation flange
Horizontal Section
V
V
minimum14 angle
H
H
A R C H I T E C T U R A L D E T A I L F I L E 7-27 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Basic Unit Details
Vertical Section
Springline™ Basic UnitScale 3" = 1'-0" (1:4)
Horizontal Section
V
V
H
H
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1/4" (6)
1/4" (6)
2-3/8" (60)
Wood frame(frame is laminated maple at curved portion only)
Wood frame
Clad aluminum
Head
SillReversible or removable installation flange
Flexible leg
Rigid notched legClad aluminum
Unit Dimension Width
Rough Opening Width
1/4" (6) 1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)
Wood frame(frame is laminated maple at curved portion only)
Clad aluminum
Reversible or removable installation flange
Jamb Jamb
Clad aluminum
Springline™ Flanker Basic UnitScale 3" = 1'-0" (1:4)
Vertical SectionHorizontal Section
V
V
H
H
Unit Dimension Width
Rough Opening Width 1/4" (6) 1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)Clad aluminum
Jamb Jamb
Wood frame Wood frame(frame is laminated maple at curved portion only)
Glass fiberreinforcedmaterial
Reversible or removableinstallation flange
Flexible leg
Rigid notched legClad aluminum
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1/4" (6)
1/4" (6)
2-3/8" (60)
Wood frame(frame is laminated maple at curved portion only)
Wood frame
Glass fiberreinforced material
Head
SillReversible or removable installation flange
A R C H I T E C T U R A L D E T A I L F I L E7-28 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
V
V
H
H
Basic Unit Details
Vertical Section
Enhancement Full Chord Basic Unitfor joining with casement, awning, double-hung, Frenchwood® hinged and Frenchwood® gliding patio doorsScale 3" = 1'-0" (1:4)
Horizontal Section
Enhancement Gothic Basic UnitScale 3" = 1'-0" (1:4)
Vertical SectionHorizontal Section
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1/4" (6)
1/4" (6)
2-3/8" (60)
Arch laminated maple
Wood frame
Clad aluminum
Head
SillReversible or removable installation flange
Flexible leg
Rigid notched legClad aluminum
Unit Dimension Width
Rough Opening Width
1/4" (6) 1/4" (6)
1-3/8" (35)
2-7/8"(73)
13/16"(21)
1-5/16"(33)
Arch laminated maple
Archlaminated maple
Clad aluminumClad aluminum
Jamb Jamb
Reversible or removable installation flange
V
V
H
H
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1/4" (6)
1/4" (6)
2-3/8" (60)
Wood frame(frame is laminated maple at curvedportion only)
Wood frame
Clad aluminum
Head
Sill
Flexible leg
Rigid notched legClad aluminum
Unit Dimension Width
Rough Opening Width
1/4" (6) 1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)
Wood frame
Clad aluminum Clad aluminum
Jamb Jamb
Reversible or removable installation flange
A R C H I T E C T U R A L D E T A I L F I L E 7-29 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Basic Unit Details
Vertical Section
Enhancement Monumental Quarter Round Basic UnitScale 3" = 1'-0 1:4)
Horizontal Section
Enhancement Monumental Full Round Basic UnitScale 3" = 1'-0" (1:4)
Horizontal and Vertical SectionHorizontal and Vertical Section
V
V
H
H
Unit Dimension Width
Rough Opening Width
1/4" (6) 1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)
Wood frame
Glass fiberreinforcedmaterial
Glass fiberreinforcedmaterial
Reversible or removable installation flange
Jamb Jamb
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1/4" (6)
1/4" (6)
2-3/8" (60)
Flexible leg
Rigid notched legClad aluminum
Arch laminated maple
Wood frame
Glass fiber reinforced material
Head
SillReversible or removable installation flange
Enhancement Octagon Basic UnitScale 3" = 1'-0" (1:4)
H & V
H & V
H & V
H & V
Unit Dimension Width
Rough Opening Width
1/4" (6) 1/4" (6)
1-3/8" (35)
2-7/8" (73)
13/16" (21)
1-5/16" (33)
Arch laminated maple Arch
laminated maple
Clad aluminum Clad aluminum
Flexible leg
Jamb Jamb
Reversible or removable installation flange
Unit Dimension Width
Rough Opening Width
1/4" (6) 1/4" (6)
1-3/8" (35)
Wood frame
Glass fiberreinforcedmaterial
Glass fiberreinforcedmaterial
Reversible or removable installation flange
Jamb Jamb
A R C H I T E C T U R A L D E T A I L F I L E7-30 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Specifying A Custom Arch UnitCustom arch windows are specified by identifying the unit width, the unit height (or shoulder height), and the radius.
Design Parameters for Custom Arch Windows
Equal Leg Design Parameters
ShoulderHeight
UnitHeight
Unit Width
ShoulderHeight
UnitHeight
Unit Width
UnitHeight
Unit Width
Height
Width
Equal Leg ArchCustom equal leg arch window units have two
sides (shoulder heights) of equal length.
Unequal Leg ArchCustom unequal leg arch window units
have two sides of different lengths.
Partial Chord ArchCustom partial chord arch window units
have one straight side and one arched side
There are certain factors that must be considered when deciding on a custom arch size or shape. Some of these factors are listed at right. For more specific design criteria, mullion joining guidelines, and sizing assistance, contact your Andersen® window and patio door supplier.
• Tempered glass may be required on large units. Contact your local building code office for specifics.
• Maximum width for mullion joined combinations equals 2 x radius.
• At least one unit dimension (height or width) must not exceed 7'-0".
• Contact your Andersen supplier when specifying High-Impact coastal units.
Custom Arch SpecificationsItem Specification
Radii Choices 18-3/4", 2', 32-1/4", 3', 4', 5', 6', 8' and 16'
Type of Operation Stationary only
Maximum Single Unit Height 12' 0"
Maximum See tables below Single Unit Width and on opposite page
Minimum Dim. No leg can be less than 6"
Max. Sq. Ft. Area Not to exceed 60 sq. ft.
Minimum Width 14" (for equal & unequal leg units)
Maximum AreaThe area (the product of the sill width multiplied by the height of the unit) must not exceed 60 square feet.
CL
Max. Width
6” Min. Leg Height
B
14” Min. Width
Unit Radius Maximum Unit Width
18.750" radius
24.000" radius
32.250" radius
36.000" radius
48.000" radius
60.000" radius
72.000" radius
96.000" radius
192.000" radius
B = 36.750"
B = 47.250"
B = 63.750"
B = 71.250"
B = 95.250"
B = 60.000"
B = 72.625"
B = 96.125"
B = 147.000"
A R C H I T E C T U R A L D E T A I L F I L E 7-31 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
CL
A
B
Maximum Offset
Maximum Width
A = the maximum offset dimension away from the center of the circle
(Rotated 90)
(min. width = 14" (356mm)
A
CL
A
B
Max. Offset
Maximum Width
(min. width = 14" (356mm)
6" Min. Leg Height
A = the maximum offset dimension away from the center of the circle
A
Design Parameters for Custom Arch Windows
Unequal Leg Design Parameters
Partial Chord Design Parameters
Unit Radius Maximum Offset from Center Maximum Unit Width
18.750" radius
24.000" radius
32.250" radius
36.000" radius
48.000" radius
60.000" radius
72.000" radius
96.000" radius
192.000" radius
B = 18.750"
B = 24.000"
B = 32.250"
B = 36.000"
B = 48.000"
B = 52.000"
B = 62.375"
B = 83.125"
B = 121.000"
A = 4.000"
A = 12.000"
A = 18.000"
A = 21.000"
A = 33.000"
A = 43.000"
A = 55.000"
A = 72.000"
A = 156.000"
Unit Radius Maximum Offset from Center Maximum Unit Width
18.750" radius
24.000" radius
32.250" radius
36.000" radius
48.000" radius
60.000" radius
72.000" radius
96.000" radius
192.000" radius
B = 18.750"
B = 23.937"
B = 32.250"
B = 35.812"
B = 47.937"
B = 30.000"
B = 36.000"
B = 48.000"
B = 123.000"
A = 4.000"
A = 12.000"
A = 18.000"
A = 21.000"
A = 33.000"
A = 43.000"
A = 55.000"
A = 72.000"
A = 156.000"
A R C H I T E C T U R A L D E T A I L F I L E7-32 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Options / Accessories
Andersen® Divided Light Grilles
White
Sandtone
Terratone®
Forest Green
3/4"
7/8"
1-1/8"
2-1/4"
With Spacer
Without Spacer
Maple
Oak
Prefinished
Pine
Colonial
Modified Colonial
Modified Col W/Check Rail
Prairie A
Short Fractional
Short Fractional W/Check Rail
Tall Fractional
Tall Fractional W/Check Rail
Victorian
Renaissance
Sunburst
Specified Equal Light
Custom
HP/HP Tempered
HP Sun/HP Sun Temp
3/8" Low-E/Temp
Single-Pane Impact
Available now
Available only with 3/8" glass through the Andersen Divided Light program
Please check with Andersen for availability
Andersen®400 Series Windows
Gla
ss
Patt
erns
In
terio
r Ty
pe
Wid
th
Exte
rior C
olor
Andersen®400 Series Doors
Case
men
t & A
wnin
g
Case
men
t Pic
ture
Win
dow
Glid
ing
Win
dow
Woo
dwrig
ht®
Doub
le-H
ung
& Tr
anso
m
Woo
dwrig
ht®
Pict
ure
Win
dow
Woo
dwrig
ht®
Arch
top
& U
nequ
al L
eg A
rcht
op
Woo
dwrig
ht®
Sprin
glin
e™ S
ingl
e-Hu
ng
Tilt-
Was
h Do
uble
-Hun
g &
Tran
som
Tilt-
Was
h Pi
ctur
e W
indo
w
Circ
le To
p™ &
Qua
rter R
ound
Arch
Sprin
glin
e™
Flex
ifram
e®
Ellip
tical
Circ
le &
Ova
l
Goth
ic
200
Serie
s Na
rrolin
e® D
oubl
e-Hu
ng &
Tran
som
Fren
chwo
od®
Glid
ing
Fren
chwo
od®
Hing
ed In
swin
g
Fren
chwo
od®
Hing
ed O
utsw
ing
Fren
chwo
od®
Patio
Doo
r Sid
elig
hts &
Tran
som
s
A R C H I T E C T U R A L D E T A I L F I L E 7-33 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Andersen® Divided Light GrillePermanent ExteriorPermanent Interiorwith Spacer
Andersen® Divided Light GrillePermanent ExteriorPermanent Interior
Andersen® Divided Light GrillePermanent ExteriorRemovable Interior
RemovableInterior
Andersen® Finelight™Grilles-Between-the-Glass
3/32"
5/16"
5/16" 7/16"
7/16"
45˚
2-1/4"
53˚3/8"3/8"3/8" 53˚
7/8"
45˚45˚
3/4"
53˚ 35˚
1-1/8"
35˚
1/2"
1-13/16"
5/16" 7/16"
2-1/4"7/8"3/4" 1-1/8"
1/2"
7/8"3/4" 1-1/8"
1/2" 1-13/16"
5/16"5/16"5/16"
3/16"1/8" 5/16"
1/2"
1/8"
1/2" 1/2" 1/2" 1/2"
Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.
Permanent Interior Wood Grille Profiles (chamfer profile).The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.
Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile).400 Series Woodwright® double-hung windows only.
Permanent Full Divided Light Grille spacer location.
Andersen® Finelight™ Grilles-Between-the-Glass.
7/16"
7/8"3/4" 1-1/8"
3/8"
3/4"
1/2"
1"
Options / Accessories
Grille Profiles • Scale = Full • Dimensions include thickness of tape.
400 Series Grille Options
A R C H I T E C T U R A L D E T A I L F I L E7-34 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
4-9/16"Wall
Unit Dim. Width
Rough OpeningWidth
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)
Face: 1-23/32" (44)
1/4" (6)
Face
: 4-9
/32"
(109
)
Face
: 3-2
3/32
" (9
5)
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
11/16"(17)
Face
: 2-
13/3
2" (6
1)
1/8" (3)
Options / Accessories
Extension JambsScale 3" = 1'-0" (1:4)
Extension jambs available for 4-9/16" (116), 5-1/4" (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 6-9/16" extension jamb is predrilled for easy application.
Horizontal Section
A R C H I T E C T U R A L D E T A I L F I L E 7-35 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Transom Joining of Equal Leg Arch
Trim Options and Applications - Arch Windows
Arch Combination
Arch Palladian / Casement Combination
Interior arch casing
Lineal interior casing by others
Plinth block
Arch interior casing
Arch interior casing
Plinth block
3/16" mull casing
Plinth block by others
Mull casing by others
Plinth block
Mull casing
Lineal interior casing by others
Plinth block by others
Mull casing by others
Arch interior casing
Arch Window
Arch Window
Casement Window
Arch Window Arch Window
Arch Window Arch Window
Arch Window Casement Window
Arch Window Casement Window
A R C H I T E C T U R A L D E T A I L F I L E7-36 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options and Applications - Arch Windows
Transom Joining of Partial Chord Arch
Extension Jamb Trim-out Arch interior casing
Plinth block
Lineal interior casing by others
Arch extension jamb
Extension jamb
Angle cut extension jamb. Plinth block or casing will conceal gap.
Arch Window
Andersen® Gliding Door
Arch Window
Frenchwood® Gliding Door
Arch Window
Frenchwood® Hinged Door
Arch Window
Casement Window
Arch interior casing
Plinth block
A R C H I T E C T U R A L D E T A I L F I L E 7-37 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Key block(standard for 4'radius Springline™ and elliptical windows for Frenchwood® hinged doors)
Note: All Springline™ units require a transition piece. Andersen® casing is not continuous
Key component
Transition piece
Plinth block
Transition piecearch casing
Transition pieceextension jamb
Transition piece stop
Transition Piece / Key Block / Plinth Block
Trim Options and Applications - Springline™ Windows
A R C H I T E C T U R A L D E T A I L F I L E7-38 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
5-3/8" (137mm)
3-3/8" (86mm)
2" (51mm)
3-3/8" (86mm)
1-1/2" (38mm)
1" (25mm)3/8" (10mm)
3/8" (10mm)
4-7/
8" (1
24m
m)
4-1/
8" (1
05m
m)
7/8" (22mm) 1" (25mm) 6" (152mm) maximum
Key block
Key component(cut to fit wall depth)
Key block
Key component
Key Block / Key ComponentScale: HalfAvailable in maple or oak.
Trim Options and Applications - Springline™ Windows
A R C H I T E C T U R A L D E T A I L F I L E 7-39 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
3/8" (10)
1" (25)
2-11/16" (68)
1-5/8" (41) for 3-1/2" (89) casing
1-7/16" (37) for 2-1/4" (57) and 2-1/2" (64) casing
Standard Andersen® transition piece casing
Optional Andersen®
transition piece extension jamb
Standard Andersen®
transition piece stop(circle style shown)
4-1/8" (105) for 3-1/2" (89) casing
3" (76) for 2-1/4" (57) and 2-1/2" (64) casing
1-1/2" (38) for 3-1/2" (89) casing
1-3/16" (30) for 2-1/4" (57) and 2-1/2" (64) casing
9/16" (14)
Cut to fit -36" (914) lengths available
Trim Options and Applications - Springline™ Windows
Transition PieceScale: HalfAvailable in maple or oak
A R C H I T E C T U R A L D E T A I L F I L E7-40 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options
Plinth BlockScale: HalfAvailable in maple or oak
5-1/4" (133mm)
4" R
1-1/2" R
3-7/8" (98mm)
For use with 3-1/2" (89mm) casing.For use with 2-1/4" or 2-1/2" (57mm or 64mm) casing.
7/8" (22mm)
4" (102mm)
3" R
1-1/8" R
2-7/8" (73mm)7/8" (22mm)
For use with 2-1/4" or 2-1/2" (57mm or 64mm) casing.
2-7/8" (73mm)
1-1/8" R
2-7/8" (73mm)7/8" (22mm)
For use with 3-1/2" (89mm) casing.
3-7/8" (98mm) 1-1/2" R
3-7/8" (98mm)
7/8" (22mm)
A R C H I T E C T U R A L D E T A I L F I L E 7-41 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options
Interior CasingScale: FullAvailable for cur ved portion of all specialty windows.
5/32" (4mm) typical
Ranch Style - WM 3242-1/4" x 11/16" (57mm x 17mm)
Available in maple or oak.
Ranch Style - WM 3152-1/2" x 11/16" (64mm x 17mm)
Available in maple only.
Colonial Style - WM 3662-1/4" x 11/16" (57mm x 17mm)
Available in maple or oak.
Colonial Style - WM 3512-1/2" x 11/16" (64mm x 17mm)
Available in maple only.
Colonial Style - WM 4443-1/2" x 11/16" (89mm x 17mm)
Available in maple or oak.
A R C H I T E C T U R A L D E T A I L F I L E7-42 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Andersen® Non-Reinforced JoiningScale 3" = 1'-0" (1:4)
Horizontal Section(vertical where applicable)
Joining Details—Flexiframe®, Arch, Springline™, Enhancement Windows
2-15/16" (75)
Unit Dim.
3/16" (5)
Unit Dim.
Optional Andersen®
wood casing
Optional Andersen®
non-reinforced wood joining material
Optional Andersen®
trim strip set in continuous sealant bead each side
Jamb Jamb
Wood fillerby others
3/16" (5)
2-15/16" (75)
Unit Dim.Unit Dim.
1-15/32" (37)
Optional Andersen® steel reinforced join
Sealant and optional Andersen®
exterior trim strip
Optional Andersen® casing for steel
JambJamb
Andersen® Steel Reinforced JoiningScale 3" = 1'-0" (1:4)
Horizontal Section(vertical where applicable)
Andersen® Aluminum Reinforced JoiningScale 3" = 1'-0" (1:4)
Horizontal Section(vertical where applicable)
2-15/16" (75)
Unit Dim.
3/16" (5)
Unit Dim.
Optional Andersen®
wood casingJamb Jamb
Wood fillerby others
Optional Andersen®
aluminum reinforcedjoin
Sealant and optional Andersen®
exterior trim strip
2" (51) Unit Dim.Unit Dim.
Optional Andersen®
extension jambs
Optional Andersen® wood filler and vinyl trim
Casing by others
Structureby others
JambJamb
2" Support Mullion JoiningScale 3" = 1'-0" (1:4)
Horizontal Section
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E 7-43 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Window is secured in the opening by using threaded fasteners through the installation flange.
Anchoring Methods—Flexiframe®, Arch, Springline™, Enhancement WIndows
Installation FlangeScale 3" = 1'-0" (1:4)
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Jamb Clip
Score markings for bending
3/16"(5)
1-1/2"(38)
3"(76)
Window unit is secured in the opening by securing a side jamb clip to the unit, pre-drilling into masonry, inserting expansion sleeve, and driving flat head screw. Vinyl flange to be cut, or removed, as required.
Window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clip to secure unit fit in opening. Installation flange can be cut as required to accommodate the jamb clip.
APPLICATION:
• First secure jamb clip to back side of window unit jamb(s)
• Apply 1' from corners of head jamb, sill and side jambs
• Space jamb clips evenly (maximum distance apart 32" on center)
• Jamb clip lateral design load capacity: maximum 200 lb.
Installation flange
Exterior sheathing
2-7/
8" (7
3)
Threaded masonry fastener / expansion sleevewith flat head screw(furnished by others).
Vinyl flange can be cut or removed as required.
Jamb clip
Wood buck
Jamb clip flat
Optional Andersen® auxiliary casing
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
Installation Flange ReversedScale 3" = 1'-0" (1:4)
2-1/
2" (6
4)
Windows over 30 square feet in size must be secured through the side jambs.
Through Jamb AttachmentScale 3" = 1'-0" (1:4)
Remove trim strip
Drill and countersink7/32" holes at an angle (as shown) on 16" centers, and within 6 inches from each corner all around.
Install #10 x 2-1/2" flathead screws through each hole, and shim where necessary.
A R C H I T E C T U R A L D E T A I L F I L E7-44 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Flexiframe®, Arch, Springline™, Enhancement Windows
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Sill
Jamb
Head
Installationflangeall around
Installationflange all around
Head
Jamb
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
*1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing.
1/2" (13)*minimum
Removeinstallationflangeat head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
Unit
Dim
.W
i dth
1/4"(6)
Installationflange allaround
Head
Jamb
Sill
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 7-45 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Flexiframe®, Arch, Springline™, Enhancement Windows
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Jamb
Head
Sill
Optional Andersen®
auxiliarycasing
Installationflangeall around
Head
Jamb
Optional Andersen®
auxiliarycasing
Optional Andersen®
extensionjambs
Sill
Unit
Dim
ensi
on H
eigh
t
Installationflange at headand jambs
Roug
h Op
enin
g He
ight
Removeinstallationflangeat sill
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Optional Andersen®
vinyl trim board
Existingframe wall
Installationflangeall around
Optional Andersen extension jambs
Head
Jamb
Sill
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Existing masonry wall
Optional Andersenextension jambstrimmed to fit
Installationflange all around
Jamb
Head
Sill
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersen®
rigid vinylchannel
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.