Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
40192-01 M_IS IFU-SP_1.9.15.indd 1 1/9/2015 9:49:20 AM
40192-01 M_IS IFU-SP_1.9.15.indd 2 1/9/2015 9:49:21 AM
Summit Cassette Model Genesis™ Container Model IN-8823 *CD3-9CDL IN-2880 *CD6-6C IN-6105 *CD5-61C
Summit Cassette Model Aesculap® Container Model IN-8823-AE *JN444 IN-2880 *JK444 IN-6105 *JN742
Summit Cassette Model Genesis™ Container Model IN-2681 *CD2-10-CDL IN-0000 *CD2-10-CDL IN-8613 *CD2-10-CDL IN-6105 *CD2-10-CDL
40192-01 M_IS IFU-SP_1.9.15.indd 3 1/9/2015 9:49:21 AM
40192-01 M_IS IFU-SP_1.9.15.indd 4 1/9/2015 9:49:21 AM
40192-01 M_IS IFU-SP_1.9.15.indd 5 1/9/2015 9:49:21 AM
1
7
6
8
9
3
4
5
2
10
40192-01 M_IS IFU-SP_1.9.15.indd 6 1/9/2015 9:49:24 AM
40192-01 M_IS IFU-SP_1.9.15.indd 7 1/9/2015 9:49:24 AM
40192-01 M_IS IFU-SP_1.9.15.indd 8 1/9/2015 9:49:24 AM
CYCLE WATER TEMP. CLEANING PROCESS Pre-wash 1 & 2 Cold Tap Water Re-circulation Time : 2 minutes
Enzyme Wash : Hot Tap Water Soaking Time : 4 minutes
Wash 1 : Heated at 65.5°C Re-circulation Time : 15 minutes
Rinse 1 & 2 Hot Tap Water Re-circulation Time : 5 minutes
40192-01 M_IS IFU-SP_1.9.15.indd 9 1/9/2015 9:49:24 AM
40192-01 M_IS IFU-SP_1.9.15.indd 10 1/9/2015 9:49:26 AM
Proper AlignmentImproper Alignment
40192-01 M_IS IFU-SP_1.9.15.indd 11 1/9/2015 9:49:28 AM
40192-01 M_IS IFU-SP_1.9.15.indd 12 1/9/2015 9:49:28 AM
STERILIZATION METHOD
Steam - PreVacuum
Ethylene Oxide (EO)
STERRAD 100SSTERRAD 100NXSTERRAD 100NX
CYCLE (times)
Parameter : Temperature 270° F (132° C) Expose Time 4 minutes Dry Time 30 minutes Preconditioning : Temperature 131°F (55°C) Relative humidity 70±15% Precondition time 1 hourSterilization : Exposure time 120 minutes Temperature 131°F (55°C) Aeration time 12 hoursStandardStandardExpress
40192-01 M_IS IFU-SP_1.9.15.indd 13 1/9/2015 9:49:28 AM
40192-01 M_IS IFU-SP_1.9.15.indd 14 1/9/2015 9:49:29 AM
40192-01 M_IS IFU-SP_1.9.15.indd 15 1/9/2015 9:49:29 AM
40192-01 M_IS IFU-SP_1.9.15.indd 16 1/9/2015 9:49:29 AM
40192-01 M_IS IFU-SP_1.9.15.indd 17 1/9/2015 9:49:29 AM
40192-01 M_IS IFU-SP_1.9.15.indd 18 1/9/2015 9:49:29 AM
40192-01 M_IS IFU-SP_1.9.15.indd 19 1/9/2015 9:49:29 AM
40192-01 M_IS IFU-SP_1.9.15.indd 20 1/9/2015 9:49:30 AM
PART DESCRIPTION SLOT MAX NO. OR TYPE OFNUMBER SIZE INSTRUMENT INSTRUMENTS SIZE
APPENDIX B (CONTINUED)
IN-6904 Hold-It, 10mm 10mm Four-10 mm Laparoscope, Short .393” .393” diameter or width One-14mmIN-6910 Hold-It, Rigid 14mm 14mm diameter or width Scope, Combo, Tall .55” .55” One-5mm diameter or widthIN-6912 Hold-It, Rigid 5mm 5mm Two-5mm Scope, Shafts, Tall .196” .196” diameter or width
One-14mmIN-6913 Hold-It, Rigid 14mm 14mm diameter or width Scope .55” .55” Two-10mm diameter or width IN-6914 Hold-It, Rigid Scope
IN-6920 Hold-It, Scissors Rear
IN-6921 Hold-It, Scissors Rear, Short
IN-6922 Hold-It, Scissors Front, Tall
IN-6923 Hold-It, Scissors Rear, Tall
IN-6924 Hold-It, Scissors Rear, Short
Ring Handles,IN-6925 Hold-It, Scissors 19mm 19mm 19mm diameter Single Post, Short .75” .75” ring handle minimum
IN-6945 Hold-It, Closed 5mm 5mm Five-5mm Top, Tall .196” .196” diameter or width
IN-6950 Hold-It, Instrument 5mm 5mm Five-5mm Tall .196” .196” diameter or width
IN-6955 Hold-It, Instrument 5mm 5mm Five-5mm Short .196” .196” diameter or width
10mm 10mm One-10mm .393” .393” diameter or width
SLOT 1:
SLOT 2:
19mm 19mm .75” .75”
26mm 26mm1.025” 1.025”
SLOT 1:
SLOT 2:
Ring Handles,19mm diameter ring handle minimum
19mm 19mm .75” .75”
26mm 26mm1.025” 1.025”
SLOT 1:
SLOT 2:
Ring Handles,19mm diameter ring handle minimum
19mm 19mm .75” .75”
9mm 9mm .357” .357”
SLOT 1:
SLOT 2:
Ring Handles,19mm diameter ring handle minimum
19mm 19mm .75” .75”
65mm 65mm 2.545” 2.545”
SLOT 1:
SLOT 2:
Ring Handles,19mm diameter ring handle minimum
19mm 19mm .75” .75”
65mm 65mm 2.545” 2.545”
SLOT 1:
SLOT 2:
Ring Handles,19mm diameter ring handle minimum
14mm 14mm Two-14mm .55” .55” diameter or width
40192-01 M_IS IFU-SP_1.9.15.indd 21 1/9/2015 9:49:30 AM
40192-01 M_IS IFU-SP_1.9.15.indd 22 1/9/2015 9:49:30 AM