40

$5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

16427 NE AIRPORT WAY, PORTLAND, OREGON 97230ISSPARTS.COM • WWW.INSTRUMENTSALES.COM

CATALOG

TO PLACE AN ORDER CONTACT OURSALES REPRESENTATIVE TODAY!

Rectangle
Typewritten text
Call - (800) 333-7976
Rectangle
Typewritten text
WWW.ISSDISTRIBUTION.COM
Page 2: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

1010627Revised 06/09/11

Section 15

Lube Level Maintainer – Model LM500/LM500-TF

The Murphy LM500-TF Oil Level Maintainer includes a test feature that confirms both the float and switch are operating correctly with a

single press of the test button. The LM500 series maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the

correct running-oil-level, it will replenish oil as it is used. The low-level switch will alarm and/or shutdown the equipment if supply oil is lost

and the equipment continues to use oil.

Application

The LM500 maintains oil level on any size engine. It also supports installations that require a 3-wire, snap-action switch.

Refer to LM500 Series Flow Rate Chart for application data.

Test Feature

The form C (3-wire) contact allows a controller/annunciator to be

wired as a closed-loop system, resulting in a reliable fault-sensi-

tive circuit.

How the LM500 Maintains Levels

As crankcase oil level drops, the LM500 float also drops and

opens the Thumb-Valve™. This allows oil to flow from the supply

tank, through the LM500, and into the crankcase. When proper

level is achieved in the crankcase, the LM500 float rises, causing

the Thumb-Valve™ to close off further oil flow.

The simple and unique Thumb-Valve™ is non-clogging and pro-

vides a positive, leak-free seal.

Thumb-Valve Operation

If the clean oil supply is depleted and oil level continues to fall, the

low level switch will operate an alarm or equipment shutdown.

Features• Test Feature (TF) allows test of float and switch

• Direct Mount (DM) capable

• Eliminates under/overfill due to “human error”

• See oil level and condition without shutting down

• Simple installation

• Automatically maintains lube level

• Low level, 3-wire, snap-action switch

• Positive sealing Thumb-Valve™

Not intended for use with fuel

Specifications

Crankcase Balance Vent Connection: 1/2 NPTF (top).

Inlet Connection: 1/2 NPTF removable screen (side).

Outlet Connection:2 x 3/4 NPTF (side)1 x 3/4 NPTF (bottom)

Thumb-Valve™ Material: Viton.

Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC.

Wire leads: 18 AWG x 14 in. ± 2 in. (355 mm) length.

Conduit Connection: 1/2 inch conduit (female, top).

Case: Die cast aluminum

Lens: Clear “Frog Eye” non-staining, high impact, high temperature polycarbonate; UV and heat stabilized.

Dial: High visibility white background with solid green band for normal level indication.

Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure).

Maximum Case Pressure: 15 psi (103 kPa).

Maximum Differential: 2 in. (51 mm) between running and stopped.

Maximum Ambient Temperature: 250°F (121°C).

Float: 304 Stainless Steel

Flow Rates: Refer to LM500 Series Flow Rates chart for application data.

Dimensions: Overall 6-9/16 inch tall x 6-3/16 inch deep x 3-1/2

deep. For exact dimensions, refer to document “00-02-0729

LM500 Installation Instructions”.

LM500/LM500-TF Shipping Dimensions: 9.5 x 7.5 x 11 in.

(241.3 x 190 x 279.4 mm).

LM500/LM500-TF Shipping Weight: 3 lbs. 13.44 oz (1.74 kg)

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 3: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

LM500 Series Flow Rates

LM500 Series Flow Rates are based on SAE 40 motor oil @ 2 ft. head pressure. Friction losses due to piping are not con-

sidered.

Typical Installations

Universal MountPipe Mount

Direct Mount

Example

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 4: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

How to Order

To order the LM500 use the model number designation diagram below. (Example for Pipe Mount: LM500-TF-PM)

Mounting Brackets with Hardware

In addition to the direct mounting option, Murphy offers two mounting brackets for the LM500. The Pipe Bracket Kit fits a

7/8 in. (22 mm) diameter pipe (see typical installation below). The Universal Flange Kit allows various mounting methods.

For exact dimensions, refer to document “00-02-0729 LM500 Installation Instructions”.

Vent Fitting Kit: 15000954One Tubing vent

One 1/4 x 1/2 NPT Connector

Hose Kit: 15000355One 1/2 in. (13 mm) I.D. x 3 ft. (914 mm) long hose

One 1 in. (25 mm) I.D. x 3 ft. (914 mm) long hose

Two 1/2 in. (13 mm) worm gear clamp

Two 1 in. (25 mm) worm gear clamp

Two 1/2 NPT x 1/2 in. (13 mm) barbed fitting

Two 3/4 NPT x 1 in. (25 mm) barbed fitting

Fittings Kit: 15000943One Tubing vent

One Hose Barb, 1/2 NPT to 1/2 Hose

One Hose Barb, 1” ID HOSE x 3/4 NPT

One Connector, 1/4 x 1/2 NPT

Accessories (Specify part number)

Description Part Number

Vent Fittings Kit 15000954

Hose Kit 15000355

1/2 NPT x 1/2 in. Hose Barbed Fitting 89080801

3/4 NPT x 1 in. Hose Barbed Fitting 89081001

Pipe Bracket Kit 15000518

Universal Flange Kit 15000519

Bubble Lens Kit 15000532

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 5: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

THIS PAGE INTENTIONALLY LEFT BLANK.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 6: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

SLS-04005B page 1 of 2

SLS-04005BEffective 10-08

Catalog Section 15 & 50(00-02-0562)Scrubber Level Control System

FWMurphy

Service TipThe MURPHYGAGE® and Filter/Regulator on the LS200NDVOR help keep the

control medium clean and dry. It also allows operator to adjust pressure to

recommended level of 30-70 psig. The MURPHYGAGE® and Filter/Regulator are

recommended to help increase system life and trouble free operation.

WarrantyA limited warranty on materials and workmanship is given with this FWMurphy product.

A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/warranty.asp.

For other options see the “How to Order” matrix.

SLS System – Automatic Level Control for Gas Scrubber Applications

You Save Money By Purchasing The SLS System

Which Includes the Following:

1) LS200 High Level Shutdown Switch

2) DVU2120 Pneumatic Dump Valve

3) LS200NDVOR Pneumatic Level Control with:

4) Filter Regulator with MURPHYGAGE®.

For detailed information on Level Switches see LS-04004B and for

Dump Valves see DVU-01069B.

Filter/Regulator &MURPHYGAGE®

“InstrumentQuality Air/Gas

Supply”

Pneumatic Level ControlFloat actuated level snap-acting switch controls

pneumatic pressure to open and close dump valve.

LS200NDVOR: Dump Valve Operator, pressure

regulator, and pressure indicating MURPHYGAGE.®

Two piece union design with manual valve operator allows soft

plug and hard seat to be replaced without disassembling outlet

piping or scrubber pipe connection. Diaphragm actuated valves

operate on 30-70 psi (207-483 kPa; 2-5 bar).

Pneumatic DumpValves See DVU-01069B

for more details.

ControlPanel

High Level Shutdown SwitchStainless steel float actuated level switches to alarm and/orshutdown the equipment.

LS200: 2” NPT pipe connection; Rated 2000 psi (13.7MPa)

[137bar]; Class I, Division 1. SPDT snap-switch standard. DPDT

Optional.

All Stainless Steel available.

The Murphy Gas Compressor Scrubber Level System (SLS)

The system provides for liquid control ingas scrubber applications, by dumpingliquids to drain and protectingcompressors with a high liquid levelswitch. Wetted metal parts are made tosurvive constant use in corrosiveenvironments.

� Designed for Harsh Gas Compressor Scrubber Applications

� 304 Stainless Steel Float Operates in 0.5 Specific Gravity and

Heavier Fluids

� Rated for Up To 2000 psi (13.8 MPa) [138 bar] Working Pressure

� Electric and Pneumatic Models Available

� Improved Design Provides Better Snap Action and

Dependability with Reduced Number of Moving Parts

� For Separators/Scrubbers to 2000 psi (13.8 MPa) [138 bar]Vessel Pressure

� Hex Union Allows Plug and Seat Replacement WithoutPiping Removal

� Operates on 30–70 psi (207–483 kPa) [2.07–4.83 bar]Control Pressure

� Manual Valve Operator

1

2

3

4

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 7: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

SLS-04005B page 2 of 2

SLS - ___

Base Models SLS2120 is the standard model in stock.

Model Dump Valve Inlet Outlet Trim Size

SLS2120: DVU2120 2 NPT 1 NPT 0.436 in. (11mm) 2000 psi

SLS2115: DVU2115 2 NPT 1 NPT 0.576 in. (15mm) 1500 psi

SLS2105: DVU2105 2 NPT 1 NPT 0.859 in. (22mm) 500 psi

SLS175: DVU175 1 NPT 3/4 NPT 0.359 in. (9mm) 1800 psi

SLS150: DVU150 1 NPT 1/2 NPT 0.359 in. (9mm) 1800 psi

Options

LR = Less regulator

Build a complete model number using the diagram below.

How to Order the SLS Series System

Approximate Shipping Weights/DimensionsSLS2120: 19 lb. 6 oz. (8.7 kg).

SLS2120: 15 x 15 x 12 in. (381 x 381 x 305 mm).3-5/8 in."(92 mm)

2-7/8 in"(73 mm)

2 NPT

4-1/2 in"(114 mm) Material: ASTM A105-2"

UNS K03504

Weld Collar (LS200 only) 15050375

10.5 in.(266 mm)

1-11.5 NPT (2 places)

1/2-20 UNF-2B(4 places)

3 in.(76 mm)

3.5 in.(89 mm) 7.01 in.

(179 mm)

2-11.5 NPT

7.55 in.(192 mm)

3 in.(76 mm)

Material: Cast Steel, WCB

Float Chamber 15051098

12-24 UNC

3/8 in(10 mm)

1 in(25 mm)

12-24 UNC

Material: AISI 303, UNS-S30300

Float Shaft Extension 15000478

NOTE: The extension is used with the LS200 only. One extension is

supplied with each unit. Use of additional extensions is not recommended

as they reduce the ability of the unit to operate for the stated specific gravity.

Accessories

Operating Pressure: 2000 psi(13.8 MPa) [138 bar]Operating Temperature: 400°F (204°C)

OperatingPressure: 2000 psi (13.8MPa) [138 bar]

OperatingTemperature: 400°F (204°C)

A

B

C

E

Dø2.19 in.(56 mm)

1/2 NPT

3.63 in. (92 mm)

2.5 in. (64 mm) Hex

3.53 in. (90 mm)

Signal out

Manual Valve Operator

TOP VIEWDVO

LS200N

Supply Exhaust

8.49 in. (216 mm)

ø2.19 in.(56 mm)

2" 11-1/2 NPT3/8 NPT exhaust

3.73 in.(95 mm)

4.59 in.(117 mm)

ø1.75 in.(44 mm)

3.30 in. (84 mm) min. clearance required for float movement.

3.44 in.(87 mm)

20BPG-75 Pressure Gage

Filter/ Regulator

Nipple 1/8 NPT x 1/8 NPT

Regulator/Gage Assembly

LS200N, LS200NDVO &LS200NDVOR

w/ Dump Valve Operator,

Pressure Regulator & Gage

LS200 and

L1100

Dump Valve

DVU2120

Dimensions

G Pressure

Inlet Port

Manual Valve

Operator

A

B

C

DE

F Drain

Connection

Plug Seal

Vent

Union

Weep Hole Valve Open/Closed

Indicator Button

(dimension shown

for reference only)G

DVU2120

A 7.5 in. (191mm)

B 8.0 in. (203mm)

C 2.85 in. (70mm)

D 1.0 in. (25mm)

E 2-11.5 NPT

F 1-11.5 NPT

G 1.03 in. (26mm)

Shipping Weight: 32 lb. ( 14.5kg).

Shipping Weight: 6 lb. ( 2.7kg).

2 NPT to 1 NPTAdaptorBushing55050617

available forSLS150 andSLS175versions

LS200 L1100A 10.16 in. (258 mm) 11 in. (279 mm)

B 3.44 in. (87 mm) 3.50in. (189mm)

C ø1.75 in. (44 mm) ø1.56 in. (40 mm)

D 2.80 in. (71 mm) 3.4 in. (71 mm)

E 2 NPT 1-1/2 NPT

Model A B C D E F GDVU2115 7.50 (191) 8.0 (203) 2.75 (70) 1.0 (25) 2-11.5 NPT 1-11.5 NPT 1.03DVU2105 7.50 (191) 8.0 (203) 2.75 (70) 1.0 (25) 2-11.5 NPT 1-11.5 NPT 1.03DVU175 7.50 (191) 6.75 (171) 2.06 (52) 1.0 (25) 1-11.5 NPT 3/4”-14 NPT .84 (21)DVU150 7.50 (191) 6.75 (171) 2.06 (52) 1.0 (25) 1-11.5 NPT 1/2”-14 NPT .84 (21)

NOTE: Dimensions are in inches and (millimeters)

MaximumWorking press.

FRANK W. MURPHY, LTD

Church Rd Laverstock

Salisbury SP1 1QZ UK

Phone: +44 172 241 0055 Fax: +44 172 241 0088

E-mail: [email protected]

Web site: www.fwmurphy.co.uk

COMPUTRONIC CONTROLS, LTD

41 - 43 Railway Terrace

Nechells, Birmingham B7 5NG UK

Phone: +44 121 327 8500 Fax: +44 121 327 8501

E-mail: [email protected]

Web site: www.computroniccontrols.com

FW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD

77 23rd Street

Hangzhou Economic & Technological Development Area

Hangzhou, Zhejiang 310018 China

Phone: +86 571 8788 6060 Fax: +86 571 8684 8878

FW MURPHY INTERNATIONAL TRADING (SHANGHAI) CO., LTD.

Suite 1704, Tower B, City Center of Shanghai; 100 Zunyi Road

Shanghai, 200051 China

Phone: +86 21 6237 2082 Fax: +86 21 6237 2083

Web site: [email protected]

FW MURPHY

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100 Fax: +1 918 317 4266

E-mail: [email protected]

INDUSTRIAL PANEL DIVISION

Fax: +1 918 317 4124

E-mail: [email protected]

MURPHY POWER IGNITION

Web site: www.murphy-pi.com

CONTROL SYSTEMS & SERVICES DIVISION

P.O. Box 1819

Rosenberg, Texas 77471 USA

Phone: +1 281 633 4500 Fax: +1 281 633 4588

E-mail: [email protected] in U.S.A.www.fwmurphy.com

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 8: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

1010629Revised 05-24-11

Section 15

MLS Series - Liquid Level Switches

MLS Series Liquid Level Switches are float activated to operate an electrical SPDT reed switch for annunciation/pilot signal

for indication of high level to an annunciator, controller or PLC. The MLS connects directly into the gas scrubber wall and

can be used with a Murphy weld collar or Murphy external float chamber. The MLS Series is available in both 2”NPT and 1-

1/2” NPT models.

Product Dimensions

.

Features• Clean Magnet Design virtually eliminates iron filing accu-

mulation onto the magnet

• Seal-Free Construction

• ANSI/ISA 12.27.01 compliant (Single Seal)

• Operates in 0.50 specific gravity or heavier fluids

• Designed for harsh gas compressor scrubber applications

• 304 cast equivalent SS body and 304 SS float

• Rated for 2000 psi (13.8 MPa) [138 bar] working pressure

• Trip on rising and falling without need to rotate body

• Electric model only available

• All models screw directly into the scrubber or can be

mounted via a Murphy external float chamber

• CSA C/US Class I, Div. 1, Grp. B, C & D locations

• NACE MR0175 compliant

• Canadian Registration Number 0F01476.2

Specifications

Process Connection: 2” NPT (MLS-020)

1-1/2” NPT (MLS-015)

Fluid Density (Sg): 0.50 MIN

Pressure Rating: 2000 psig (13.8 MPa) [138 bar]

Materials:

Body: ASTM A351 CF8 (304 SS)

Cover: ASTM A351 CF8 (304 SS)

Other Wetted Parts: 304 or 316 SS

Meets NACE MR0175 for direct exposure to H2S

Process Temperature: -20 to 300oF (-24 to 149oC).

Electrical: 30VAC/VDC 75mA Form C SPDT

Conductor cross section AWG/kcmil min.: 26

Conductor cross section AWG/kcmil max.: 16

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 9: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Electrical Wiring Diagram

How to Order

To order the MLS Series Level Switch please specify one of the products listed below:

MLS-020 (2” NPT)

MLS-015 (1-1/2” NPT)

Accessories

Refer to MLS Installation and Operations manual for additional information.

External Float Chamber 15700799

Operating Pressure: 2000psi (13.8MPa)[138 bar]

Operating Temperature: 400oF (204oC)

Shipping Weight: 18lbs (8.2kg)

Approximate Shipping Weights and Dimensions (all models)

Weight: 5.5 lbs (2.49kg)

Dimensions:14 x 5 x 3.5 in (356 x 127 x 89 mm)

Weld Collar 15050375

Operating Pressure: 2000psi (13.8MPa)[138 bar]

Operating Temperature: 400oF (204oC)

Shipping Weight: 6lbs (2.7kg)

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 10: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

00010Revised 08-27-09

Section 15

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. MURPHY, and the Murphy logo,

are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all

rights reserved. (c) 2007 Murphy Industries, Inc.

Lube Level Maintainer – Model LM2000/LM2000S

Murphy LM2000 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct run-

ning-oil-level, the LM2000 will replenish oil as it is used. An integral, low-level switch will alarm and/or shutdown the equip-

ment if supply oil is lost and the equipment continues to use oil.

Application

The LM2000 maintains oil level on any size engine, as well as installations that require a 3-wire, snap-action switch. Refer

to Flow Rate for application data.

How the LM2000 Maintains Levels

As crankcase oil level drops, the LM2000 float also drops

and opens the Thumb-Valve™. This allows oil to flow from

the supply tank, through the LM2000, and into the crank-

case. When proper level is attained in the crankcase, the

LM2000 float rises, causing the Thumb-Valve™ to close off

further oil flow.

The simple and unique Thumb-Valve™ is nonclogging and

provides a positive, leak-free seal.

Thumb-Valve Operation

If the clean oil supply is depleted and oil level continues to

fall, the low level switch will operate an alarm or equipment

shutdown.

Features• Eliminates under/overfill due to “human error”

• See oil level and condition without shutting down

• Simple installation

• Automatically maintains lube level

• Low level, 3-wire, snap-action switch

• Positive sealing Thumb-Valve™

Not intended for use with fuel

Specifications

Crankcase Balance Vent Connection: 1/2 NPTF (top).

Inlet Connection: 1/2 NPTF removable screen (side).

Outlet Connection:LM2000 3/4 NPTF (bottom)

LM2000S 2 x 3/8 NPTF (side)

1 x 3/4 NPTF (bottom)

Thumb-Valve™ Material: Viton.

Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC.

Wire leads: 18 AWG x 14 in. ± 2 in. (355 mm) length.

Conduit Connection: 1/2 inch conduit (female, top).

Case: Die cast aluminum

Lens: Clear “Frog Eye” non-staining, high impact, high temperature polycarbonate; UV and heat stabilized.

Dial: High visibility white background with green and white “index” lines for normal level indication.

Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure).

Maximum Case Pressure: 15 psi (103 kPa).

Maximum Differential: 2 in. (51 mm) between running and stopped.

Maximum Ambient Temperature: 250°F (121°C).

Float: Brass

Flow Rates: SAE 40 motor oil @ 32°F (0°C) with 2 ft. head pressure: 0.5 GPH

Dimensions: Overall 4-5/8 inch tall x 2-7/8 inch deep. For exact dimen-

sions, refer to document “00-02-0423 LM2000 Installation Instructions”.

LM2000/LM2000S Shipping Dimensions: 9 x 5-1/2 x 6 in.

(229 x 140 x 152 mm).

LM2000/LM2000S Shipping Weight: 3 lbs. 6 oz. (1.5 kg)

NOTE: Friction losses due to piping not considered.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 11: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Warranty - A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the war-

ranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

Mounting Brackets with Hardware

Murphy offers two mounting brackets for the LM2000. The 15000238 Pipe Bracket Kit fits a 7/8 in. (22 mm) diameter pipe

(see typical installation below). The 15010224 universal Flange Kit allows various mounting methods. For exact dimensions,

refer to document “00-02-0423 LM2000 Installation Instructions”.

How to Order

Specify model LM2000 LM2000S

Typical Installation

Optional Vent Fitting Kit: 15000954Kit sold separately–includes the following items:

1 Tubing vent (15050202).

1 1/4 x 1/2 NPT Connector (85030447).

Optional Hose Kit: 150003551 1/2 in. (13 mm) I.D. x 3 ft. (914 mm) long hose (89020202)

1 1 in. (25 mm) I.D. x 3 ft. (914 mm) long hose (89020203)

2 1/2 in. (13 mm) worm gear clamp (00003502)

2 1 in. (25 mm) worm gear clamp (00003503)

2 1/2 NPT x 1/2 in. (13 mm) barbed fitting (89080801)

2 3/4 NPT x 1 in. (25 mm) barbed fitting (89081001)

Accessories (Specify part number)Description Part NumberVent Fittings Kit 15000954

Hose Kit 15000355

1/2NPT x 1/2 in. Hose Barbed Fitting 89080801

3/4NPT x 1 in. Hose Barbed Fitting 89081001

3/8NPTF x 1/2 in. Hose Barbed Fitting 89080601

Pipe Bracket Kit 15000238

Universal Flange Kit 15010224

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 12: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

060000907-27-10

Section 15

LS200 & L1100 Series Liquid Level Switches

PENDING

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 13: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase
Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 14: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase
Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 15: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase
Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 16: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

92149Revised 07-27-10

Section 15

Level Maintainer – LM300 Series

Description

The LM300 Series Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. Most models have built-in switches that will alarm and/or shutdown the equipment if the makeup supply is depleted and engine oil level falls or if overfill conditions exist. LM300 series explo-sion-proof models are CSA certified† for Class I, Division 1 Hazardous areas.

Applications

• Engines

• Compressors

• Pumps

• Coolers

Base Models‡

LM300: Level Maintainer only (no switches).

LM301: Low switch contacts for low level shutdown or alarm. Four wires, SPDT.

LM302: Two switches for low and high level shutdown or alarm. Four wires, DPST, wired N.O. in normal operating ranges.

LM303: Two switches for low and high level shutdown or alarm. Four wires, DPST, wired N.C. in normal operating ranges.

LM304: Two switches. Alarm before shutdown on low level and shutdown on low-low level. Four wires, DPST, wired N.O. in normal operating ranges.

LM305: Two switches. Alarm before shutdown on low level and shutdown on low-low level. Four wires, DPST, wired N.C. in normal operating ranges.

Specifications

Case/Cover: Die cast aluminum.

Switch Housing: Aluminum.

Approval Rating: LM301 thru LM305: CSA certified† for non hazardous locations. Enclo-sure Type 4 certified.LM301-EX thru LM305-EX: CSA certified† for Class I, Groups C and D; Class II, Groups F and G hazardous locations. Enclosure Type 4 certified.

Float: Rigid polyurethane foam. Polyurethane coated.

Max. Ambient Temperature: 250°F (121°C)

Oil Inlet Connection: Top entry 1/2-14 NPT with built-in filter screen (removable for cleaning).

Inlet Orifices: 1/4 in. (6 mm) standard. 1/8 in. (3 mm) available.

Wire (switch models): 18 AWG x 13 in. (1.0 mm2 x 330 mm).

Max. Inlet Pressure (MIP): 30 psi (207 kPa) [2.07 bar]. with 1/8 in. (3 mm) orifice.15 ft oil (4.6 m oil) with 1/4 in. (6 mm) orifice.

Max. Differential: 2 in. (51 mm) between running and stationary oil level.

Max. Case Pressure (MCP): 15 psi (103 kPa) [1.03 bar].

Orifice Seal†: Buna-N Thumb-Valve™

Switch Contact: Silver, SPDT snap acting, rated at 10 A @ 125, 250 VAC; 10 A @ 30 VDC. (1 only for low level; 2 only for high and low; or 2 only for low level with alarm before shutdown)

Flow Rate Test: Using SAE 30 @ 32°F (0°C).

Outlet Connection: 3/4-14 NPT left side, right side, and bottom.

Crankcase Balance Vent Fitting: 1/2-14 NPT.

Mounting: Accepts Murphy pipe mounting bracket or universal mounting bracket.

Lens: Clear “Frog Eye” non-staining, high impact, high temperature nylon; UV and heat stabilized.

Dial: High visibility white background with green and white “index” lines for normal level indication.

Test Knob: Rotate to test switch operation. Turn clockwise for low level test and turn counterclockwise for high level test.

LM301-EXPatent 5493086

Features• Maintains proper lube level

• Shutdown on low level, or high and low level

• Low level alarm before shutdown

• Manual float switch test

• High visibility “Frog Eye” lens

• Optional pipe or universal mounting brackets

• Optional inlet orifices for low to high pressure applications

• Explosion-proof models available

*

* Pending

† Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.

† CSA certified with switch contacts rated at 10 A at 250 V AC (standard).‡ Specify “EX” for explosion-proof enclosure. All models except LM300 are available in an explosion-proof enclosure.

Orifice Diameter Pressure Flow Rates

1/4 in.* (6 mm)

* Standard

4 ft. oil – 15 ft. oil (1.2 m oil – 4.6 m oil)

4.7 GPH - 31.0 GPH (17.8 LPH - 117.3 LPH)

1/8 in. (3 mm) 10 psig – 30 psig (68.9 kPa – 207 kPa)

[.69 – 2.07 bar]

16.9 GPH - 32.1 GPH (63.7 LPH - 121.5 LPH)

NOTE: Friction losses due to piping NOT considered.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 17: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Dimensions

The dimensions below are for the optional “EX” model enclosure. The standard model enclosure dimensions are the same except the height and width which are: 7 in. (178 mm) H, 7-7/8 in. (200 mm) W.

Mounting Brackets with Hardware

How to Order

Build a complete model number using the following chart. See example. See reverse page for standard and optional specifications.

Shipping InformationShipping Weights:• LM300 Series non-“EX” models: 6 lbs. 6 ozs. (2.89 kg)

• LM300 Series “EX” models: 6 lbs. 12 ozs. (3.06 kg)

Shipping Dimensions (all LM300 Series models):• 10-5/8 x 8-7/8 x 6-3/4 in. (270 x 225 x 171 mm)

Optional Hose Kit: 15000355Quantity Description

1 1/2 in. (13 mm) I.D. x 3 ft. (914 mm) long hose

1 1 in. (25 mm) I.D. x 3 ft. (914 mm) long hose

2 1/2 in. (13 mm) worm gear clamp

2 1 in. (25 mm) worm gear clamp

2 1/2 NPT x 1/2 in. (13 mm) barbed fitting

2 3/4 NPT x 1 in. (25 mm) barbed fitting

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 18: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

0710176 page 1 of 2

For Small Engines and Pumpsn See Oil Level and Condition

Without Shutting Downn Shutdown or Alarm on Low Lube Leveln Adjustable Limit Switch for Alarm

and/or Shutdownn Save on Reduced Downtime

and Repair Costsn Simple Installation

DescriptionThese float actuated Oil Level Swichgage instru-ments are a combination oil level sight gage andadjustable, low and/or high limit switch. Thelimit switches are normally open during opera-tion–yet close if the level drops (or rises) towhere the float contacts the limit screw. The con-tact completes a circuit to ground a magneto ortrip a Murphy magnetic switch. The magneticswitch can be used to activate alarms and/orshutdown. Models are also available withoutlimit switches.

ApplicationThe level instruments described above can beused on a variety of crankcases, pump gearcases,or oil reservoirs–primarily on small engines andpumps. The following list displays the modeland its typical application: L100†: Small engines and pumps with

non-vented crankcase.L100W†: Small engines and pumps with

vented crankcase.L120: Machined surface on crankcase such as

Witte, National-Oilwell/Garland.L127: Machined surface on crankcase, specifi-

cally, Fairbanks-Morse ZC Series and Bell Engines.

L128: Machined surface on crankcase, specifical-ly, Arrow and Continental Emsco/Climax.

Specificationsn Maximum Pressure Rating (all models):

30 psi (207 kPa) [2.07 bar]n L100 and L100W

Case: Die cast aluminumFloat: BrassRating: 2 A @ 30 VAC/DCVent Fitting: 1/4 in. (6 mm) tube x 1/8 NPTInlet Fitting: Hex Nipple 1/4 NPTHardware (shipped loose)

L100:• Copper Tubing: 1/4 x 48 in. dia.

(6 mm x 1.2 m)• Reducer Bushing: 1/2 NPT x 1/4 NPT• Close Nipple: 1/2 NPT• Tee: 1/2 NPT, black pipe• Wire: 16 AWG x 24 in. (1.5 mm2 x 610mm)L100W:• Vent Tube: 1/4 x 3-3/8 in. (6 x 86 mm)• Reducer Bushing: 3/4 NPT x 1/4 NPT• Close Nipple: 3/4 NPT• Tee: 3/4 NPT, black pipe• Wire: 16 AWG x 24 in. (1.5 mm2 x 610mm)

n L120Case: Cast AluminumFloat: BrassRating: 2 A @ 30 VAC/DCMounting Bolts: 1/4-20 UNC–2A (4 req'd)

n L127 and L128Case: TROGAMID® NylonFloat: BrassRating: 2 A @ 30 VAC/DCWire: 16 AWG x 48 in. (1.5 mm2 x 1.2 m)Mounting Bolts:

• L127: 1/4-20 NC x 2 in. (4 required)• L128: 3/8-16 NC x 3/4 in. (2 required)

WarrantyA limited warranty on materials and workmanshipis given with this FW Murphy product. A copy ofthe warranty may be viewed or printed by going towww.fwmurphy.com/support/warranty.htm

L100

L120

L127/L128

† Models available with high and low options. See How toOrder on reverse side

**Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.

**

0710176Revised 03-07

Catalog Section 15Float Actuated Oil Level Swichgage® instrument

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 19: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

0710176 page 2 of 2

Typical Wiring Diagram

How to OrderSpecify base model designator and options insequence shown below. Example: L100-HL.

DimensionsL100 and L100W

L120

L127 and L128

CL27/32 in.(21 mm)

3-1/8 in.(79 mm)

2-1/8 in.(54 mm)

2-1/8 in.(54 mm)

4-5/16 in.(110 mm)

3-3/8 in.(86 mm)

2-7/32 in.(56 mm)

Mounting Holes 4 places, 5/16 in. (8 mm) diameter

2-7/32 in.(56 mm)

2-3/4 in.!(70 mm)

2 in.* *!(51 mm)

2-1/2 in.*!(64 mm)2-15/64 in.!

(57 mm) Mounting** !holes 4 places!5/16 in. (8 mm)!diameter

2-15/64 in.!(57 mm)

** Applies to L127 only * Applies to L128 only

47/64 in.!(19 mm)3/8 in.!

(10 mm) 17/32 in.!(13 mm)

1-17/32 in.!(39 mm)Mounting!

holes 2 places!5/16 in. (8 mm)

Oil inlet !holes

L128 Mounting DimensionsBase Model (refer to “Application” section)L100: Sight gage with low limit switch.L100W: Same as L100 except fittings.L120: Sight gage with low limit switch.L127: Sight gage with low limit switch.L128: Sight gage with low limit switch.

____ - ____

Shipping Weight:• L127: 8 oz (0.23 kg)• L128: 10 oz (0.36 kg)

Shipping Dimensions (L127 and L128):4-3/4 x 4-3/4 x 3-1/4 in. (121 x 121 x 83 mm)

Shipping Weight: 1 lb 8 oz (0.68 kg) Shipping Dimensions: 4-3/4 x 4-3/4 x 3-1/4 in. (121 x 121 x 83 mm)

Shipping Dimensions: • L100: 5-1/4 x 5-1/4 x 5-1/2 in.

(133 x 133 x 140 mm)• L100W: 4-3/4 x 4-3/4 x 3-1/4 in.

(121 x 121 x 83 mm)Shipping Weight:

• L100: 2 lbs. (0.91 kg)• L100W: 2 lbs. (0.91 kg)

MagnetoMurphy !magnetic !switchFloat

OR

OptionBlank: Low contact.LF: Less fittings and hardware.

Below is a typical wiring diagram for a levelSwichgage instrument. A Swichgage instru-ment can be connected to a Murphy magneticswitch or magneto. Switch Contact Rating is 2 A @ 30 VAC/DC resistive.

CONTROL SYSTEMS & SERVICES DIVISIONP.O. Box 1819Rosenberg, Texas 77471 USAPhone: +1 281 633 4500 Fax: +1 281 633 4588E-mail: [email protected] W. MURPHY, LTDChurch Rd LaverstockSalisbury SP1 1QZ UKPhone: +44 172 241 0055 Fax: +44 172 241 0088E-mail: [email protected] site: www.fwmurphy.co.uk

COMPUTRONIC CONTROLS, LTD41 - 43 Railway Terrace NechellsBirmingham B7 5NG UKPhone: +44 121 327 8500 Fax: +44 121 327 8501E-mail: [email protected] site: www.computroniccontrols.comFW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD 77 23rd StreetHangzhou Economic & Technological Development AreaHangzhou, Zhejiang 310018 ChinaPhone: +86 571 8788 6060 Fax: +86 571 8684 8878

FW MURPHYP.O. Box 470248Tulsa, Oklahoma 74147 USA +1 918 317 4100 Fax: +1 918 317 4266 E-mail: [email protected] PANEL DIVISIONFax: +1 918 317 4124E-mail: [email protected] POWER IGNITIONWeb site: www.murphy-pi.com www.fwmurphy.com Printed in U.S.A.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 20: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

L-6572B page 1 of 2

L129 Seriesn Check Lube Level Without

Shutting Downn Use On Engines, Pumps,

And Compressorsn Combination Indicating Gage with

Low and High Limit Switchn Float Operated

DescriptionThe L129 Series Lube Level Swichgageinstrument is a combination lube level indi-cating gage and adjustable low and high limitswitches. It provides protection against lowoil level or high level caused by overfill orfuel or water seepage into the crankcase. A 6-3/4 inch (171 mm) deep sight gaugeallows you check the condition and level ofyour oil without shutting down the equipment.Fingertip adjustable limit contacts, thru 4-7/8 inch (122 mm) range, make it simple toset high and low limit contacts. If the floattouches the high or low limit contact, a normal-ly open circuit will be completed which canactivate alarms and/or shutdown the equipment. There are two models in the L129 Series:L129 and L129CK1. The L129 model isdesigned for grounded, low voltage electricalsystems. It features a one-wire-to-ground elec-trical circuit. The L129CK1 was designed forapplications requiring a three-wire, aboveground electrical circuit. It features unground-ed contacts and a conduit hub to protect electrical wiring.

Options are available for both models.A flow restrictor plug is available that restricts oil flow from the crankcase to the L129 Seriesswitch and vice versa. It is typically used onapplications where the engine is not stationarysuch as marine and mobile equipment.The L129 Series Lube Level SWICHGAGE®,when properly installed and maintained, canmonitor and protect your engines and pumpsfrom improper lubrication level, which canresult in extensive damage.

ApplicationsThe L129 Series is recommended for enginesand pumps with larger crankcase capacity.Although designed primarily for stationaryengines, the L129 Series is often used inmobile applications such as marine, rail, andsome large off-highway trucks. SpecificationsCase: Die Cast Aluminum.Lens: Tempered Glass.Maximum Working Pressure:10 psi (68.9 kPa).

Process Connection: 1/2 NPT.Float Material: Brass.

Contact Rating: 2 A @ 30 VAC/DC, pilot duty.

Shipping Weight:L129: 3 lb. (1.4 kg).L129CK1: 3 lb. 9 oz. (1.6 kg).

Shipping Dimensions (both models):12 x 4-1/2 x 4-3/4 in. (305 x 114 x 121 mm).

WarrantyA limited warranty on materials and workmanshipis given with this FW Murphy product. A copy ofthe warranty may be viewed or printed by going towww.fwmurphy.com/support/warranty.htm

L129

L129CK1

* Products covered by this bulletin comply with EMC Councildirective 89/336/EEC regarding electromagnetic compatibilityexcept as noted.

*

L-6572BRevised 06-06

Catalog Section 15Lube Level Swichgage® instrument

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 21: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Wiring Diagrams

Dimensions

8 in.(203 mm)

3-3/16 in.(81 mm) 2-31/64 in.(63 mm)

Shock Mount(2 supplied)

Keps nut(2 supplied)

Low LevelAdjustHigh LevelAdjust

1-1/2 in.(38 mm)2 in.(51 mm)

1/2 NPT Closed Nipple(2 supplied)

1/2 NPT Union(1 supplied)

HighContact

LowContact

Float

+ +

+ +

+ +

+ +

-

-

-

-

9-55/64 in.(250 mm)

HighContact

1/2 NPTConduit

LowContact

Float

4-55/64 in.(123 mm) 2-31/64 in.(63 mm)

Low LevelAdjustHigh LevelAdjust

1-1/2 in.(38 mm)2 in.(51 mm)

1/2 NPT Closed Nipple(2 supplied)

1/2 NPT Union(1 supplied)

+

+ +

+ +

+ +

+ -

-

-

-

Shock Mount(2 supplied)

Keps nut(2 supplied)

L129 L129CK1

L129 L129CK1

Contact Rating: 2 A @ 30 VAC/DC, pilot duty.

These diagrams are shown with the float in the “full” position.

HIGH (Black)LOW (Red)COM (White)LOWHIGH

L-6572B page 2 of 2

Repair KitsSpecify part number. L12915000888 Full Repair Kit (less castings and glass ass’y) for date code T2 and later.

15000480 Bezel, Glass and Gasket Set for date code W7 and later15000485 Glass and Gasket Set for all date codes15050241 Restrictor plug for all date codesL129CK115000480 Bezel, Glass and Gasket Set for date code W7 and later15000485 Glass and Gasket Set for all date codes15050241 Restrictor plug for all date codes

Printed in U.S.A. 8 5 0750

In order to consistently bring you the highest quality, full featured products, we reserve the right to change ourspecifications and designs at any time. MURPHY, the Murphy logo, and Swichgage® are registered and/or commonlaw trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyrightprotected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.www.fwmurphy.com918.317.4100 Email: [email protected]

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 22: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Model LR857n Eliminates Under/OverFill Due to

“Human Error”n Simple Installationn Automatically Maintains Lube Leveln Low Level Switchn Models to Fit Varied Applicationsn Positive Sealing Thumb-Valve™

LR857

DescriptionMurphy LR857 Lube Level Regulator maintainsthe crankcase oil level of an engine, pump orcompressor. Adjusted to the correct running-oil-level, the LR857 will replenish oil as it is used. Anintegral, low-level switch will alarm and/or shut-down the equipment if supply oil is lost and theequipment continues to use oil.

ApplicationThe LR857 maintains oil level on any size engine,but is recommended for small to medium volumeapplications and installations that require a 3-wire,snap-action switch.

How the LR857 Maintains LevelsAs crankcase oil level drops, the LR857 float alsodrops and opens the Thumb-Valve.™ This allowsoil to flow from the supply tank, through theLR857, and into the crankcase. When properlevel is attained in the crankcase, the LR857 floatrises, causing the Thumb-Valve to close off fur-ther oil flow.The simple and unique Thumb-Valve is non-clogging and provides a positive, leak-free seal.Flow rate through the 1/8 inch (3 mm) orifice issignificant to allow crankcase refill through the LR857.

SpecificationsInlet Connection: 5/8 in. (16 mm) I.D. hoseOutlet Connection: 3/8 NPTSnap-switch: SPDT rating 10 A @ 125 VAC; 0.5 A @ 125 VDC; 10 A @ 30 VDC.Conduit Connection: 1/2 NPTCase: Die cast aluminumLens: PolycarbonateFloat: BrassFlow Rates (see chart below):Oil with 0.9 specific gravity @ 70°F (21°C)

Thumb-Valve OperationAs the equipment uses oil, the float falls, provid-ing immediate level compensation. At FULLposition, the float holds the valve closed. If theclean oil supply is depleted and oil level contin-ues to fall, the low level switch will operate analarm or equipment shutdown.

Fittings Kit: 15000420The 15000420 kit is sold separately. It includesthe following items.Quantity Description

1 1/4 in. (6 mm) O.D copper cane tube (vent connection)

1 1/4 in. (6 mm) tube x 1/4 male pipe fitting

1 1/2 in. (13 mm) I.D. hose fitting (outlet connection)

WarrantyA limited warranty on materials and workmanship isgiven with this FW Murphy product. A copy of thewarranty may be viewed or printed by going towww.fwmurphy.com/support/warranty.htm

0

05

10

15

20

25

0

Flow: USGPM

He

ad

Pre

ssu

re–F

ee

t o

f O

il

Head P

ress

ure

–psi

0 psi

9.73 psi

0.2500 0.5000

COM.N.O.

Low Level!Switch

LR857!Case

Float!Action

Oil InletThumb-Valve™

FULL

LOW

N.C.

Simplified Drawing ofThumb-Valve Operation

**Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.

**

LR-7225BRevised 03-05

Catalog Section 15(00-02-0063)Maintain Lube Level

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 23: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

For vented crankcase use thecane vent. For sealedsystems, vent must bepiped back to crankcase, above oil level.

Shutoff Valve

CLEAN Oil Supply Tank.Height above LR recommended2 ft. (0.6 m) minimum and25 ft. (7.7 m) maximum

Wire to switchcircuits

LR857

Oil Outlet

ElectricalConduit

Crankcase

OilInlet

NOTE: LR857 shown mountedusing a pipe bracket.

LR857 Typical

Installation

4.50 in.(114 mm)

5.20 in.(132 mm)

2.50 in.(64 mm)

Hole .88 in.(22 mm) dia.

1/4-20 NC2 places

.376 in.(10 mm)minimumbottom surface2 places

1.75 in.

(44 mm)

7.50 in.

(191 mm)

Slot, .390 in. (10 mm)x 4.71 in. (120 mm)3 places

6.69 in.(170 mm)

Slot, .390 in. (10 mm)x 2 in. (51 mm)4 places

4.50 in.(114 mm)

5.19 in.(132 mm)

4-13/16 in.(122 mm)

4-15/16 in.(125 mm)

4-1/2 in.(114 mm) Mounting Holes

Plug1/2 NPT

1/4 NPT

2-25/32 in.(71 mm)

9/32 in. (7 mm)Diameter Holes2 places

5/8 in. (16 mm)I.D. Inlet HoseConnection1/4 NPT Internal Threads

TestKnob

Plug3/8 NPT

1/2 NPTElectricalConduitConnection

3/8 NPTOutletConnection

!

How to OrderSpecify model LR857

Accessories (Specify part number)Description Part NumberFittings Kit 15000420 Pipe Bracket Kit 15000238 Universal Flange Kit 15010224 Replacement Parts (Specify part number)Inlet Valve Assembly 15000159Glass and Switch Ass'y 15000100Lid Assembly 15000161Float Assembly (Brass-std) 15000941

LR857 Shipping Dimensions: 9 x 5-1/2 x 6 in. (229 x 140 x 152 mm). LR857 Shipping Weight: 3 lbs. 6 oz. (1.5 kg).

Mounting Brackets with HardwareMurphy offers two mounting brackets for the LR857. The 15000238 PipeBracket Kit fits a 7/8 in. (22 mm) diameter pipe (see typical installationbelow). The 15010224 universal Flange Kit allows various mounting methods.

Dimensions

15000238Pipe Bracket Kit

15010224Universal Flange Kit

Additional Hardware Supplied(2) 1/4-20 x 7/8 inch

(22 mm) screws(2) 1/4-20 x 1 inch

(25 mm) screws(4) 1/4-20 hex nuts(4) 1/4 inch (6 mm)

dia. split washer

Additional Hardware Supplied(2) 1/4-20 x 1-1/4 inch

(32 mm) bolts(4) 1/4 dia. flat washer(2) 1/4-20 hex nuts(2) 5/16-18 x 1-1/4 inch

(32 mm) bolts(4) 5/16 dia. flat washer(2) 5/16-18 hex nuts

LR-7225B page 2 of 2

CONTROL SYSTEMS & SERVICES DIVISION

P.O. Box 1819; Rosenberg, Texas 77471; USA

+1 281 633 4500 fax +1 281 633 4588

e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje

San Luis Potosí, S.L.P.; México 78384

+52 444 8206264 fax +52 444 8206336

Villahermosa Office +52 993 3162117

e-mail [email protected]

www.murphymex.com.mx

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.

+44 1722 410055 fax +44 1722 410088

e-mail [email protected]

www.fwmurphy.co.uk

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

FW MurphyP.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100 fax +1 918 317 4266

e-mail [email protected]

www.fwmurphy.comPrinted in U.S.A. 850740B

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 24: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

n Unique Anti-Clog Thumb-Valve™

n Regulate Oil Flow From Reservoir to Keep Lubricator Full

n Eliminates Manual Oil Check and Refill Time

n Low-level Shutdown Switch

n Reduce Engine and Pump Repairs Caused By Low Lube Level

Model LR579

Regulates Lincoln Lubricators

Models LR589 and LR589NC

Regulates Lincoln Lubricators

18 AWG x 24 in. (1.0 mm2 x 610 mm) Wire with Ring Terminal

18 AWG x 30 in. (1.0 mm2 x 762 mm) Switch Wires

1/2 NPT ConduitConnection

1/2 NPT Oil Inlet Connection

Tenzalloy Case

Hermetically-SealedMercury Switch

Low Level Shut-Down Contacts

304 Stainless Steel Float

304 Stainless Steel Float

1/2 NPT Oil InletConnection

Cane Vent

Pressure-Seal Thumb-Valve with Viton

Pressure-Seal Thumb-Valve with Viton

AluminumCase

Suitable for Class I,Division 2, HazardousLocations

Electrical Diagram

LR589 Electrical Diagram LR589NC Electrical Diagram

Switch Rating: 2A @ 20 V AC/DC, resistive

Switch Rating: 1A @ 120 V Switch Rating: 1A @ 120 V

LR500 Series

LREG-96121BRevised 08-02

Catalog Section 15(00-02-0062)Oil Level Regulators for Lubricators

DescriptionThe LR500 Series Level Regulators automatically add oil to a

lubricator to maintain the factory recommended level. This

function eliminates the work time necessary for manual checks

and refills.

Each model has a low-level shutdown switch to protect equip-

ment when oil supply is lost. If the lubricator oil level drops

below the minimum operations level, the low-level switch will

operate an alarm and/or shutdown the equipment.

Model LR579 is for Lincoln lubricators. It features an

adjustable low-level shutdown contact.

LR589 is for Lincoln lubricators, and the LR589NC is the nor-

mally closed wired version of the LR589.

How to OrderSpecify model when ordering.

LR579

LR589

LR589NC

WarrantyA limited warranty on materials and workmanship is given with this FWMurphy product. A copy of the warranty may be viewed or printed bygoing to www.fwmurphy.com/support/warranty.htm

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 25: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Dimensions

WARNING

Before beginning installation of this Murphy product:

4 Disconnect ALL electrical power to the machine.

4 Make sure the machine CANNOT operate during installation.

4 Follow all safety warnings of the machine manufacturer.

4 Read and follow all installation instructions.

1. Remove the cover on a vacant cell of the lubricator

(DO NOT install in bays next to crank arm).

2. Bolt the level regulator in place, using the bolts that

held the cover.

3. Connect the flex hose from the oil reservoir to the oil

inlet at the level regulator. Oil reservoir must be at

least two feet (0.61 meters) above the level regulator.

4. Wire switch for alarm and/or shutdown. One switch

can be used to shut-down all equipment supplied by a

common oil reservoir.

4-7/16 in.(113 mm) 9/32 in.

(7 mm)diameter2-places

5 in.(127 mm)

1-1/2 in.(38 mm)

Vent Tube1/4 inch (6 mm) Copper

1 InchHex

ContactAdjustment

Screw

Float

1-1/8 in.(29 mm)

3/4 in.(19 mm)1-1/2 in.

(38 mm)

Switch Operating Point2-1/2 in.(64 mm)

4-1/16 in.(103 mm)

4-7/16 in.(113 mm)

5-1/16 in.(129 mm)

Float

9/32 in.(7 mm)diameter2-places

CD Ignition

Murphy MS2100Magnetic Switch

6 2 3 541

CD Ignition

Murphy MS2100Magnetic Switch

6 2 3 541

Installation

Typical Wiring for LR579

LR579 LR589 / LR589NC

Typical Wiring for LR589

Shipping Weight: 13 oz. (368 g).

Shipping Dimensions: 4-3/4 x 4-3/4 x 3-1/4 in.

(121 x 121 x 83 mm).

Shipping Weight: 12 oz. (340 g).

Shipping Dimensions: 4-3/4 x 4-3/4 x 2-3/4 in.

(121 x 121 x 70 mm)

LREG-96121B page 2 of 2

CONTROL SYSTEMS & SERVICES DIVISIONP.O. Box 1819; Rosenberg, Texas 77471; USA+1 281 633 4500 fax +1 281 633 4588 e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336Villahermosa Office +52 993 3162117e-mail [email protected]

FRANK W. MURPHY, LTD.Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.+44 1722 410055 fax +44 1722 410088 e-mail [email protected]

MURPHY SWITCH OF CALIFORNIA41343 12th Street WestPalmdale, California 93551-1442; USA+1 661 272 4700 fax +1 661 947 7570e-mail [email protected]

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MACQUARRIE CORPORATION1620 Hume HighwayCampbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558e-mail [email protected]

FW Murphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100

fax +1 918 317 4266

e-mail [email protected]

www.fwmurphy.com

RE

GISTER

ED

USA–ISO 9001:2000 FM 28221UK–ISO 9001:2000 FM 29422

Printed in U.S.A.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 26: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

LEL-00072B page 1 of 2

L150/ EL150K1 Seriesn Monitors Level of Coolant, Lube Oil,

Diesel Fuel And Hydraulic Fluid.n Indicating Gaugen Low Limit Switchn Float Operated n Explosion-Proof Model Is Available.

DescriptionThe L150 Series Level Swichgage instrument isa combination liquid level gauge and low limitswitch; each unit includes (1) a chamber withpivotal float, (2) an indicating dial with pointer,and (3) a low level contact. When properlyinstalled and maintained, the float operates thepointer which, in turn, both indicates level dur-ing normal operation, and closes a switching cir-cuit if the level falls to the low-limit set point.

ApplicationsThe primary use of the L150/EL150K1 is forengine cooling systems, surge or expansiontanks, condenser radiator or vapor phase sys-tems, pressurized or atmospheric systems. TheLevel Swichgage instrument can also be used tomonitor lube oil, hydraulic fluid or diesel fuelreservoirs and activates alarms and/or shut-downat a predetermined minimum level.These instruments are built for low pressure systemswith a maximum of 25 psi (172 kPa) [1.72 bar].L150 SpecificationsCase: Die cast aluminum, poly-urethane coated;approximate dimensions; 4-1/2 x 4-3/4 x 2-3/4 in. (114 x 121 x 70 mm).Mounting Holes: (2) 9/32 in. (7 mm) diameterat 4-1/2 in. (114 mm) on center.Float: Brass.Lens: Polycarbonate.

O-rings: Saturated Nitrile, are suitable forcoolant or hydrocarbons. Maximum temperature250°F (121°C).Gasket: Nitrile.Vent Tube: 1/4 x 5 in. (6 x 127 mm) coppercane with 1/4 NPT x 1/4 in. (6 mm) tube fitting.Contact Rating: 2 A @ 30 VAC/DC.Wire: (1) 16 AWG x 26 in. (1.5 mm2 x 660 mm)with terminals.Shipping Weight: 29 oz. (0.82 kg.).Shipping Dimensions: 5-1/4 x 5-1/4 x 5-1/2 in. (133 x 133 x 140 mm).

EL150K1 SpecificationsCase: Die cast aluminum, poly-urethane coated;approximate dimensions; 5 x 4-3/4 x 2-3/4 in.(127 x 121 x 70 mm).Mounting Holes: (2) 9/32 in. (7 mm) diameterat 4-1/2 in. (114 mm) on center.Float: Brass.Lens: Polycarbonate.O-rings: Saturated Nitrile, are suitable forcoolant or hydrocarbons. Maximum temperature250°F (121°C).Gasket: Nitrile.Vent Tube: 1/4 x 5 in. (6 x 127 mm) coppercane with 1/4 NPT x 1/4 in. (6 mm) tube fitting.Snap-Switch: SPDT rated 10 A @ 125 VAC;0.5 A @ 125 VDC; 10 A 30 VDC.

Wire: (3) 18 AWG x 14 in. (1 mm2 x 356 mm).Shipping Weight: 42 oz. (1.2 kg.).Shipping Dimensions: 5-1/4 x 5-1/4 x 5-1/2 in. (133 x 133 x 140 mm).

EL150EX SpecificationsCase: Sand cast aluminum, painted; approxi-mate dimensions; 6-1/2 x 5-3/4 x 5-1/4 in. (165x 146 x 133 mm).Mounting Holes: (2) 5/16 in. (8 mm) diameterat 5-1/2 in. (140 mm) on center.Float: 304 Stainless steel.Lens: Tempered glass.O-rings: Saturated Nitrile, are suitable forcoolant or hydrocarbons. Maximum temperature250°F (121°C).Gasket: Nitrile.Vent Tube: 1/4 x 5 in. (6 x 127 mm) coppercane with 1/4 NPT x 1/4 in. (6 mm) tube fittingand 1/2 NPT to 1/4 NPT reducer fitting.Snap-Switch: SPDT rated 10 A @ 125 VAC;0.5 A @ 125 VDC; 10 A 30 VDC.Wire: Wired to terminal block.Laboratory Approvals: CSA Listed for Hazardous Locations Class I,Division 1, Groups C & D.Shipping Weight: 5 lbs. (2.26 kg.).Shipping Dimensions: 6-1/2 x 6-3/4 x 6-3/8 in.(165 x 171 x 162 mm).

** Products covered by this bulletin comply with EMCCouncil directive 89/336/EEC regarding electromagneticcompatibility except as noted.

EL150EX Models are CSA Listed for Class I,Division 1, Group C & D Hazardous Locations.

EL150EX

EL150K1L150

LEL-00072BRevised 06-06

Catalog Section 15Level Swichgage® InstrumentFor Engine Liquids

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 27: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

LEL-00072B page 2 of 2

Radiator FittingsMurphy PS, PS Barbed and PS-D fittings allow the installation ofthe L150/EL150K1 to the radiator when a fitting is not available. • 15-00-0107 (PS): thin wall, 1/4 in. (6 mm) tube fitting.• 15-01-0167 (PS-Barbed): thin wall, 1/4 in. (6 mm) tubing or hose.• 15-01-0202 (PS-D): for diesel or oil, thick wall (to 1/4 in. [6 mm]),

accepts 1/2 in. (13 mm) I.D. hose or 1/4 in. (6 mm) O.D. tubing.

15010235 FM315010236 FM415010237 FM515010238 FM1215010349 CECO

Dimensions

Standard Electrical Diagrams

Fittings Kits Order Separately

Full

Low

Full

Low

NC-RedNO-Black

Common-!White

15-00-0107 (PS) 15-01-0167 (PS Barbed)

4-13/16 in.(122 mm)

3-25/32 in.(96 mm)

4-1/2 in.(114 mm)

Mounting Holes1/2-14 NPT

1/2 NPTBack Connect

(optional)

1/4 NPT2-3/4 in.(70 mm)

9/32 in. (7 mm)diameter holes

2 places

MountingEars (2)

TestKnob

4-13/16 in.(122 mm)

4-15/16 in.(125 mm)

4-1/2 in.(114 mm)

Mounting Holes1/2-14 NPT

1/2 NPTBack Connect

(optional)

1/4 NPT2-3/4 in.(70 mm)

9/32 in. (7 mm)diameter holes

2 places

11/16 in.(17 mm)

TestKnob

5-9/16 in.(141 mm)

4-11/16 in.(119 mm)

5-1/2 in.(140 mm)

Mounting Holes1/2-14 NPT

6 in.(152 mm)

1/2 NPTConnection

5/16 in. (8 mm)diameter holes

2 places

L150

L150

EL150K1

EL150K1

EL150EX

EL150EX

Repair KitsL15015-00-0138 All parts except case and body15-00-0101 Case/body assemblyEL150K115-00-0139 All parts except case and body15-00-0101 Case/body assembly15-00-0100 Lens/switch assemblyEL150EX15-00-0110 Cover and float assembly15-00-0108 Lid assembly15-00-0109 Switch/terminal assembly

NCNOC Low

Full

AccessoriesSpecify Description15-00-0107 Radiator fitting (PS)15-01-0202 Radiator fitting (PS-D)15-01-0167 Radiator fitting (PS Barbed)

WARNING: This typical wiring diagram is shown for clarity only.It is not intended for use as installation instructions.

WarrantyA limited warranty on materials and workmanship is given with this FWMurphy product. A copy of the warranty may be viewed or printed bygoing to www.fwmurphy.com/support/warranty.htm

In order to consistently bring you the highest quality, full featured products, we reserve the right to change ourspecifications and designs at any time. MURPHY, the Murphy logo, and Swichgage® are registered and/or commonlaw trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyrightprotected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.www.fwmurphy.com918.317.4100 Email: [email protected]

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 28: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

OPLH-94122B page 1 of 4

OPLH / OPLHACS Seriesn Combination Level Indicating Gage and

Critical Level Limit Switch n High and Low Level Limit Contacts Are

Visible and Adjustablen Designed to Start and Stop Pumps to

Maintain Specific Levels n Indication only Murphygage® instrument

Availablen Latching Control Relay Versions Available

DescriptionThe OPLHC/OPLHACS Series LevelSwichgage instruments are combinationlevel indicating gages with adjustable lowand high limit switches. Limit switches canbe wired directly to electric pilot circuits tooperate alarms, shutdown or start/stoppumps to maintain predetermined levels. Surface mount or panel mount enclosure isavailable for both model series. All modelsfeature a 4-1/2 in. (114 mm) dial for easyviewing. Adjustable limit switches areaccessible from front of the Swichgageinstrument.Specialized models are available for specificapplications involving engines or electricmotors. OPLHC/OPLHACSSeries Swichgage instrumentsinclude 2-adjustable, pilot duty, pointer typecontacts. Contacts have self-cleaning motionto enhance electrical continuity. Models areavailable with a rugged bourdon-tube or 316stainless steel bellows sensing element forgreater accuracy and sensitivity in lowerranges.

A “freeze-proof” sensor of 316 stainless steelwith Buna-N rolling diaphragm, is available.The “freeze-proof” sensor (OPLHAFP)inserts approx., 2 in. (52 mm) inside a tank. OPLHBP/OPLHABPSInternal latching control relays are availableto provide ON/OFF automation for electricmotor applications.OPLHC and OPLHACS series are avail-able in indication only Murphygage models(OPLHAGS). See Page 2 to determine themodel for your application.

Applications• Saltwater Disposal Systems• Waterflood Systems • Diesel Day Tanks• Oil Storage Tanks

Basic OperationThe OPLHC/OPLHACS series operate fromstatic head pressure. Pressure is transmittedto the process connection of the Swichgageinstrument. From here the pressure flexes the bourdontube or operates the 316 stainless steel bel-lows (depending on which model you have).The bourdon tube/bellows oper-ates the stainlesssteel rotarygeared movementwhich in turn operatesthe indicating pointer onthe face of the dial. Whenthe pointer (A) closes with thelimit contact (B), a control circuit(C) is completed and signals an alarm and/orshutdown or starts/stops a pump.

WarrantyA limited warranty on materials and workmanshipis given with this FW Murphy product. A copy ofthe warranty may be viewed or printed by going towww.fwmurphy.com/support/warranty.htm

R

Selected configurations are third party listed. ConsultFWMurphy for details.

OPLHFC

OPLHACS

A

AdjustmentKnobBC

OPLH-94122BRevised 03-06

Catalog Section 154-1/2 in. (114 mm) Dial Level Swichgage® instrument

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 29: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

OPLH-94122B page 2 of 4

(1) Bourdon tube (OPLHC) models in the 20 ft. (6 m) range have an accuracy of 3% full scale.(2) ES option available for the 20 ft. (6 m) range models and above.NOTES:• Options may not be available in combination. Consult factory.• Over range is not to exceed 10% FS above full range.• Calibration is for water. Specify for other liquids.• Add TOTAL height of liquid above the pressure connection to determine correct range (dial scale). For elevated tanks substract the tank elevation from gage reading to determine actual tank level.

OPLH / OPLHA SeriesOPLHC

OPLHFCOPLHCE

OPLHACSOPLHACES

OPLHBPOPLHABPS

OPLHBPEOPLHABPES

OPLHGOPLHFG

OPLHAGSOPLHAGES

OPLHAFCSOPLHAFGS

Enclosure Type (die cast aluminum)• Surface mount, square case• Panel mount, round case• Panel mount, square caseLimit Switch Ratings• Pointer Contacts: SPDT center off; 2 A, 30 VDC, 1 A, 125 VAC. Latching Control Relay• SPDT,10 A @ 120 VAC (standard)• DPDT, 12 VDC (Optional)• DPDT, 24 VAC (Optional)• DPDT, 24 VDC (Optional)Sensing Element• Bourdon Tube, Bronze/Brass (standard)• Bellows, 316 Stainless Steel (standard)Process Connections• 1/4 NPT Male • 1/4 NPT Female• 2 NPT MaleGeared Movement: 300 series stainless steel.Accuracy (standard calibration is for water)• ±2% first/last quarters of scale, 1% middle half scale. (1)• 3% full scale.OPTIONS AVAILABLE (specify when ordering)• Environment sealed for isolation from the elements (ES). (2)• Explosion-proof case; Class I, Div. 2, Groups C & D (EX)• Explosion-proof less case; internal gage mechanism without case (EL)• Less case; internal gage mechanism without case (LC)• Tickler contact (TA)RANGES AVAILABLE (specify when ordering)• 0–5 ft. (0–1.5 m) dual scale dial• 0–10 ft. (0–3 m) dual scale dial• 0–20 ft. (0–6 m) dual scale dial• 0–30 ft. (0–9 m) dual scale dial• 0–60 ft. (0–18 m) dual scale dial• 0–120 ft. single scale dial• 0–3.6 metres single scale dial• 0–4 metres single scale dial• 0–6 metres single scale dial• 0–9 metres single scale dial

Specifications

Shipping DimensionsItem Dimensions: 16 x 11 x 5-1/2 in. (406 x 279 x 140 mm).Explosion-proof models: 12 x 12 x 9 in. (305 x 305 x 229 mm).Shipping WeightsItem Weight: 8 lb. (3.6 kg) approximately.Explosion-proof models: 22 lb. (10 kg) approximately.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 30: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

OPLH-94122B page 3 of 4

8 in.(203 mm)

6-25/64 in.(162 mm)8 in.(203 mm)

Rear mounting holesfor surface mounting3/8-16 UNC-2B7/8 in. (22 mm) deep, 4 places.Removable lidto access adjustablecontact knobs.

6-3/4 in.(171 mm)

6-3/4 in.(171 mm)

Mounting Hole 7-35/64 in. (192 mm) diameter. Not required for surface mounting.

1/2 NPToptionalrear or sideconduit

3/8-16 UNC-2B7/8 in. (22 mm) deep, 4 places.

Process Connection1/4 NPT Female

Explosion-proof Enclosure (“EX” Option)

8-7/16 in.(214 mm) 3-3/8 in.(86 mm)

7-7/8 in.(200 mm)

3-15/16 in.(100 mm)

4-1/32 in.(102 mm)

Mounting Holes9/32 in. (7 mm)diameter 3 places.Not available on panel mount square case.

1/2 NPT conduit

Process Connection1/4 NPT male on bourdon tube modelsand 1/4 NPT female on bellows models. Surface

NOTE:Panel mount square case modelsdo not includemounting flange andinclude bolt circleshown in Panel MountEnclosure versions(see below).

120

120

120

5-7/16 in.(138 mm) 2-57/64 in.(73 mm)

Mounting Hole4-3/4 in. (121 mm)diameter. Process Connection1/4 NPT Male.Panel

1/4 in. (6 mm) dia. holes (3 places.) on 5-13/64 in. (132 mm) b.c. (bolt circle),120apart, clockingas shown

DimensionsSurface / Panel Mount Enclosure (Square Case)

Panel Mount Enclosure(Round Case)

Typical ApplicationsAbove Ground Tank Below Ground Tank

SWICHGAGE®

Flow regulator (recommended)

PressureregulatorHeadPressure

Air compressor

Tank

TankSWICHGAGE®Direct Mount

RemoteSWICHGAGE®with Sensing LineUnderground

Direct and Remote Tank

Flow regulator (recommended)Pressureregulator

SWICHGAGE®

1 foot

Ground surface

Air compressor

Underground tank (vented)

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 31: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

OPLH-94122B page 4 of 4

How to Order

Base Part Numbers

Latching Control Relay Voltage (applies to “BP” models only)Blank = 120 VAC2 = 12 VDC4 = 24 VDC

Bourdon Tube/BellowsOPLHC Standard=Bronze/BrassOPLHACS Standard=316 Stainless Steel

Range/Scale (specify in feet)*Bellows Tube

05 = 0-5 ft. X10 = 0-10 ft. X20 = 0-20 ft. X X30 = 0-30 ft. X X60 = 0-60 ft. X120 = 0-120 ft. X*Standard calibration is for water–specify

for other.

Options (see Specifications on page 2 for availability)

ES = Environmentally sealedEX = Explosion-proofEL = (EXLC) Explosion-proof less caseLC = Less caseTA = (TCA) Tickler contact

Internal Wiring

Red White Black

120 VAC

BLUEYELLOW

BROWN

WHITE

= 18 GA.= 16 GA.

BLACK

RED ORANGELOW!(RESET) HIGH!

(SET)

SET

RESET3

6

4

17

9

A B

8

35

4

1

2 6LINE

NEUTRAL

COMMON

Contact Ratings: SPDT center off; 2 A, 30 VDC, 1 A, 125 VAC pilot duty. Contact Ratings: SPDT dry relay contacts,

10 A, 125 VAC.

OPLHC, OPLHACS,and OPLHAFPSeries

Red White Black

OPLHCE, OPLHFC, OPLHACES and OPLHAFCSSeriesOPLHBP, and OPLHABPS Series

Specify model number. NOTE: No designator is required for Standard configurations. Also, list options in alphabetical order (A to Z). Place a dash (–) between each option. See example below.

OPLHBP – – 2 – 30 – TAOPLHGOPLHGEOPLHCOPLHBPOPLHAGSOPLHACSOPLHABPS OPLHAFCSOPLHAFGSOPLHFG

OPLHFCOPLHCEOPLHABPGSOPLHBPEOPLHAGESOPLHACES45LHE45LHEF45LHEBP

Tamperproof Contact AccessoryKnobLock

LimitSwitchKnobs

Order 05000610

In order to consistently bring you the highest quality, full featured products, we reserve the right to change ourspecifications and designs at any time. MURPHY, the Murphy logo, Swichgage® and Murphygage® are registeredand/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustra-tions, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.www.fwmurphy.com918.317.4100 Email: [email protected]

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 32: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

L971 Series

n Durable Low Level Switch

n Replaces Non-Explosion-proof Switch onIngersoll-Rand Compressors

n Adaptable to Other Compressors

n Installs with Minimal Downtime

n Two Year Limited Warranty

DescriptionThe Murphy L971 Series Level Switch detects

low oil level in a compressor’s crankcase.

As oil level in the crankcase depletes, the

float on the L971 switch falls, and if reaches

the predetermined limit, will trip the internal

snap-switch which in turn will initiate a

shutdown and/or alarm.

The L971 is designed for Ingersoll-Rand

Type 30, Type 40 and ESH compressors, yet

can be adapted to fit other compressors that

have an inspection plate extending below

normal operating oil level.

The L971 has a 1/2 NPT process connection

and features an explosionproof enclosure,

durable SPDT snap-switch and rigid

polyurethane foam float. A 304 stainless steel

float is available on certain configurations (see

Specifications).

SpecificationsOperating Temperature Range:

-15 to 275°F (-26 to 135°C).

Maximum Working Pressure:

30 psi (206 kPa) [2.06 bar].

Switch Rating: 4 A @ 250 VAC.

Material

Case: Aluminum (explosion-proof).

Mounting Adaptor: Brass.

Floats: Rigid polyurethane. 304 stainless steel available on L971-C only.

Other Wetted Parts: 303, 304, and 316 stainless steel.

O-Ring Seals: Viton and Buna.

Process Connection: 1/2 NPT.

Enclosure Rating: UL and CSA listed for

Class I, Groups C & D; Class II, Groups F

& G, Hazardous Locations.

Conduit Connection: 1/2 NPT.

Wire: 18 AWG (0.75 mm2).

Shipping Weight: 1 lb. 10 oz. (0.7 kg).

Shipping Dimensions: 8-1/4 x 4-1/4 x

4-1/2 in. (210 x 108 x 114 mm).

WarrantyA limited warranty on materials and workmanshipis given with this FW Murphy product. A copy ofthe warranty may be viewed or printed by going towww.fwmurphy.com/support/warranty.htm.

R

Wiring Diagrams*

Green

RedYellow

Red

Green

BlackYellow

Model L971-A

All Other Models

*Shown in “shelf” position with no force acting upon float.

**Products covered by this bulletin comply with EMCCouncil directive 89/336/EEC regarding electromagneticcompatibility except as noted.

**

L-7229BRevised 02-97

Catalog Section 15(00-02-0059)Crankcase Level Switch

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 33: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

To order the L971 Series Level Switch to fit your application, use the diagram below.

Example model number: L971-C

L971 – ____

How to Order

Dimensions

TOP TOPTOP

TOP

L971-D and L971-E L971-F L971-G

TOP

21°

TOP

21°

L971-AModel

Case/Float

Configuration

(front view,

less cover

and gasket)

Case/Float

Configuration

(front view,

less cover

and gasket)

NOTE: Switches shown tripped on falling level.

Model

L971 and L971-B L971-C

D

AFloat arm is adjustable but cannot beremoved.

1/2 NPT

Float is removableand replaceable

3 in.(76 mm)

1/2 NPT

B C

E

A B C D EL971 2-5/8 (67) 5-7/8 (149) 30 (762) 2-1/2 (64) 2-27/32 (72)

L971-A 2-5/8 (67) 5-7/8 (149) 30 (762) 2-1/2 (64) 2-27/32 (72)

L971-B 4-13/16 (122) 8-1/16 (205) 30 (762) 4-5/8 (117) 2-27/32 (72)

L971-C 2-13/16 (71) 6-1/16 (154) 30 (762) 2-7/8 (73) 3-1/8 (79)

L971-D 3-7/8 (98) 7-1/8 (181) 30 (762) 3-3/4 (95) 2-27/32 (72)

L971-E 4-13/16 (122) 8-1/16 (205) 30 (762) 5-1/8 (130) 2-27/32 (72)

L971-F 2-5/8 (67) 5-7/8 (149) 40 (1016) 2-1/2 (64) 2-27/32 (72)

L971-G 2-5/8 (67) 5-7/8 (149) 40 (1016) 2-1/2 (64) 2-27/32 (72)

*Millimeter dimensions are shown in parenthesis ().

Dimensions in inches* (see drawing right)

Models

Case/Float Configuration (see chart below)

Blank = Standard configuration

A = Configuration A

B = Configuration B

C = Configuration C

D = Configuration D

E = Configuration E

F = Configuration F

G = Configuration G

L-7229B page 2 of 2

CONTROL SYSTEMS & SERVICES DIVISIONP.O. Box 1819; Rosenberg, Texas 77471; USA+1 281 633 4500 fax +1 281 633 4588 e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336Villahermosa Office +52 993 3162117e-mail [email protected]

FRANK W. MURPHY, LTD.Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.+44 1722 410055 fax +44 1722 410088 e-mail [email protected]

MURPHY SWITCH OF CALIFORNIA41343 12th Street WestPalmdale, California 93551-1442; USA+1 661 272 4700 fax +1 661 947 7570e-mail [email protected]

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MACQUARRIE CORPORATION1620 Hume HighwayCampbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558e-mail [email protected]

FW Murphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100

fax +1 918 317 4266

e-mail [email protected]

www.fwmurphy.com

RE

GISTER

ED

USA–ISO 9001:2000 FM 28221UK–ISO 9001:2000 FM 29422

Printed in U.S.A. 0777070

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 34: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

DF Seriesn Salt Water Disposal Systems n Cooling Towersn Crude Oil Tanksn Waterflood Systemsn Diesel Day Tanksn Sumps

DescriptionThe DF series are diaphragm operated “hydrosta-

tic head pressure” level switches. A pressure

sensitive diaphragm operates a snap-switch that

can be wired directly to electric pilot circuits to

control pumps at predetermined levels. Typical

application is to start and stop electric driven

pump(s) to maintain tank levels. It is also applica-

ble to engine driven pumps.

The nitrile sensing diaphragm is impervious to

most liquids and is sensitive enough to control

levels with 1/4 in. (6 mm) repeatability. See

model descriptions for limits of switch trip point

adjustability. Materials include aluminum body,

nylon bottom plate and a special alloy leaf snap-

switch as standard.

This simple level switch is highly reliable and can

be worked into almost any new or existing system

without major modification or special tools.

DF755 and DF757 are suitable for atmos-

pheric tanks in a non-hazardous area. The

SPDT snap-switch for the DF755 is preset for

a 4 in. (102 mm) differential in liquid level.

The DF757 trip point is adjustable over a 108

in. (2743 mm) differential.

DF755EX is the same as the DF755 except

CSA listed for Class I, Division 1, Groups C

and D hazardous areas.

Applications

• Water Flood Systems

• Crude Oil Tanks

• Salt Water Disposal Systems

• Diesel Day Tanks

• Sumps

• Cooling Towers

SpecificationsSnap-switch Ratings

SPDT (standard–all models)• 5 A @ 125, 250, or 480 VAC • 1/2 A @ 125 VDC, 1/4 A @ 250 VDC

DPDT (optional)• 10 A @ 28 VDC

10 A @ 120, 230 VAC

Case/Lid: Aluminum (standard).

Bottom Plate: Glass-filled Nylon.

Process Connection: 1 NPT (standard).

Maximum Pressure Rating: 25 psi (172 kPa [1.72 Bar]).

Conduit Connection (electrical): 1/2 NPT.

1 NPT

(standard)

6-5/32 in.

(156 mm)

5-1/2 in.

(140 mm)

1/2 NPT

For Electrical

Connection

7-21/32 in.

(194 mm)

5-5/8 in.

(143 mm)

1 NPT

(standard)

1/2 NPT

Plug

1/2 NPT

For Electrical

Connection

DF755 and DF757

Dimensions

DF755EX

*CSA listing applies to DF755EX 20 in. (508 mm) or less water column differential, 5A @ 125, 250, or 480 VAC.

**Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.

*

**

DF-94124BRevised 10-03

Catalog Section 15(00-02-0053)Hydrostatic Head Level Switches

WarrantyA limited warranty on materials and workmanshipis given with this FW Murphy product. A copy ofthe warranty may be viewed or printed by going towww.fwmurphy.com/support/warranty.htm

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 35: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Typical Water Flood Control System

The diagram above displays eight DF Series switches installed on a

Raw Water tank and a Clear Water tank. When raw water rises to

predetermined level, DF#1 stops the supply pump. As tank level

falls below the predetermined level, DF#2 starts the supply pump. If

the tank level continues to fall, DF#3 initiates shutdown of the sup-

ply pump. DF#4 stops transfer pump before raw water tank is com-

pletely pumped out.

When clear water reaches the predetermined level, DF#5 stops the

transfer pump. As tank level falls to predetermined low level, DF#6

starts the transfer pump. If the tank level continues to fall due to the

failure of the filters section, DF#7 initiates shutdown of the transfer

pump. (DF755 located at this level will also operate backwash

equipment). DF#8 stops injection pump before tank pumps com-

pletely out.

An OPL Series Pressure SWICHGAGE® stops injection pump when

pressure reaches predetermined high or low pressure.

Transfer

PumpSupply

Pump

Raw Water Tank Clear Water Tank

Injection PumpDF#1

DF#2

DF#3

DF#4

DF#5

DF#6

DF#7

DF#8

OPL Series

SWICHGAGE®

Filter

Tank with Low Pressure

Gas Blanket (DF755EX)

The DF level switch (below) is shown installed on a crude oil tank

where a low pressure gas blanket is used to prevent evaporation loss.

It is mounted directly to the side of the tank or on riser pipe 4 to 7 in.

(102 to 178 mm) below level to be controlled. Pump automatically

stops or starts when liquid reaches predetermined high or low level.

Fuel Tank

Gas Blanket

Gas Liquid

Typical Tank Mounting Methods (DF755)

Tank Wall Mounting with Drain Cock

Bull Plug Installation

Directly on Tank Riser Pipe Method

Tank Wall Mounting

Applications

DF-94124B page 2 of 4

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 36: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

N.O.

C

N.C.

HIGH

N.O.

C

N.C.

LOWMOTOR

DF755

#1

DF755

#2

MAGNETO

N.O.

C

N.C.

Starts at Low Level, Stops at HighStart motor when predetermined low level is reached and stop whenhigh level is reached. Keeps tank level within selected limits. Motorstarter equipped with H.O.A.

MOTOR

N.O.

C

N.C.

HIGH

N.O.

C

N.C.

LOW

DF755

#1

DF755

#2

Starts at High Level, Stops at LowStart motor when predetermined high level is reached and stop whenlow level is reached. Motor starter equipped with H.O.A.

Single Magneto ShutdownShut down single ignition engine when fluid reaches low level.Simple wiring of magneto to N.O. switch terminal will shut downengine at predetermined high level, shown below.

N.O.

C

N.C.

6 2 3 5Magneto

Magneto

1 4

Jumper #2 & #5

Model MS2120

Dual Magneto ShutdownShut down dual magneto engines using Murphy MS2120 MagneticSwitch. Diagram below shows hookup for low level shutdown.Simple wiring changes and mounting locations are necessary forhigh level shutdowns.

Basic Operation

Typical Wiring

A

BC

Hydrostatic HeadPressure

DF755EXTube Fitting

B

C

A

Hydrostatic HeadPressure

Hydrostatic HeadPressure

B D

A

C

As the liquid level rises, hydrostatic head pressure is applied to the

diaphragm A. The diaphragm is forced upward forcing the actuator

arm B to activate the snap-switch C.

Models DF755 and DF755EX are factory set and operate at approx-

imately 2 in. (51 mm) and 6 in. (152 mm) above the level at which

the diaphragm is mounted. The trip point(s) for Model DF757 are

adjustable between 2 in. (51 mm) and 110 in. (2794 mm) for high

and low (make/break) operation by knobs, D.

For sealed tanks, model DF755EX has a tube fitting to balance the

top of the diaphragm chamber to a tank gas blanket (see

Applications).

DF755

DF755EX

DF757

DF-94124B page 3 of 4

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 37: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Base ModelDF755DF755EXDF757 (not available in explosionproof)

BodyBlank: Aluminum

SwitchS = SPDT, 15AD = DPDT, 10A

Bottom ConnectionBlank = 1 in. NPT

To order the DF series, use the model number designation diagram below.

Murphy offers the MAC-1 Volume Air Cell that can be attached to

the DF755 to monitor water levels on a sump. Activates alarms or

start a pump directly. The MAC-1 Volume Air Cell is non-corrosive

and provides 1/4-20 stainless steel mounting studs.

The MACT-1 Tubing Kit provides 4 ft. (1.2 m) flexible, non-corro-

sive 1/4 in. (6 mm) tubing (cut to fit). The kit includes necessary fit-

tings to attach tubing.

Volume Cell OperationAs liquid rises around the volume cell, it compresses air inside the

cell and forces it up in the sensor line. As air pressure increases due

to the water level continuing to rise, sufficient pressure will be

applied to activate the internal snap-switch, which in turn starts the

pump. As the liquid level is pumped down, pressure decreases and

the above procedure is reversed. The pump is stopped and held in a

standby condition. An air purge may be required in the sensor line.

Consult factory.

AIR

Sensor Line(MACT-1 Tube Kit)

DF755

Volume Cell(MAC-1)

DF755 S

Accessories The accessories below are sold separately and are available

from Murphy.

Specify

MAC-1: air volume cell

MACT-1: air volume cell tube kit

Accessories

How to Order

Shipping Weights

DF755: 3 lb. (1.4 kg)

DF755EX: 6 lb. 9 oz. (3 kg)

DF757: 3 lb. (1.4 kg)

Shipping Dimensions

DF755, DF757, 6-1/4 x 6-1/4 x 6-1/4 in.

(159 x 159 x 159 mm)

Service Parts: DF Series

15000123 Diaphragm Repair Kit

Service Parts: DF755 Series

15000121 Snap-switch, and insulator assembly

15000122 Snap-switch, insulator and movement assembly

15000313 Movement and bracket assembly

Service Parts: DF757 Series

15000174 Snap-switch and bracket assembly

DF-94124B page 4 of 4

CONTROL SYSTEMS & SERVICES DIVISIONP.O. Box 1819; Rosenberg, Texas 77471; USA+1 281 633 4500 fax +1 281 633 4588 e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336Villahermosa Office +52 993 3162117e-mail [email protected]

FRANK W. MURPHY, LTD.Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.+44 1722 410055 fax +44 1722 410088 e-mail [email protected]

MURPHY SWITCH OF CALIFORNIA41343 12th Street WestPalmdale, California 93551-1442; USA+1 661 272 4700 fax +1 661 947 7570e-mail [email protected]

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MACQUARRIE CORPORATION1620 Hume HighwayCampbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558e-mail [email protected]

FW Murphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100

fax +1 918 317 4266

e-mail [email protected]

www.fwmurphy.com

RE

GISTER

ED

USA–ISO 9001:2000 FM 28221UK–ISO 9001:2000 FM 29422

Printed in U.S.A.

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 38: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

BLSK1 Series

n Operates Bilge Pumps or Alarms

n Uses Proven “Air Cell” Actuated System

n Remote Switch and Moving Parts KeptUnaffected by Corrosion

n Aluminum Body and Cover

n Includes 3 Assemblies:

(1) BLS1 Bilge Level Switch

(2) MACT1 Tube Kit (Sensor Line and Fittings)

(3) MAC1 “Air Cell” (Volume Cell)

DescriptionThe BLSK1 Bilge Level Switch System gives

you all items and fittings necessary to install in

your bilge. Or, you can have only the parts you

want and you provide brackets, tubing and mount-

ing hardware.

Using the proven “Air Cell” actuating system, all

moving parts and switching are remote from bilge

liquids and are thus not affected by corrosion,

rust, etc. All wetted parts are of non-corrosive

materials.

As bilge level rises a column of air is captured in

the MAC1 Air Volume Cell. The rising bilge

level compresses the column of air creating pres-

sure against the large diaphragm in the BLS1

Bilge Level Switch and the switch trips. Switch

set point is adjustable.

The switch resets as the bilge is pumped out. Air

cell recharges itself during normal operation.

The BLS1 is constructed of materials not affected

by marine atmospheres; Aluminum or Bronze

body and cover, Buna-N diaphragm.

SpecificationsBLS1 Bilge Level SwitchSnap-Switch SPDT (standard)• 5 A @ 125, 250, or 480 VAC • 1/2 A @ 125 VDC, 1/4 A @ 250 VDC

NOTE: A pilot relay may be used for highercontact ratings (see Typical Wiring Diagram).

Case/Lid: Aluminum (std).Bottom Plate: Glass-filled Nylon.

Process Connection: 1/4 NPTF.

Max. Pressure: 25 psi (172 kPa) [1.72 bar].

Conduit Connection (electrical): 1/2 NPT.

BLS1 Weight: 3 lb. (1.4 kg).

BLS1 Dimensions: 6-1/4 x 6-1/4 x 6-1/4 in.

(159 x 159 x 159 mm).

15050737 Optional mounting bracket16 ga., 304 stainless steel (see Dimensions).

MACT1 Tube Kit (fittings included)4 ft. (1.21 m) flexible non-corrosive

tubing, 1/4 in. (6 mm) dia. (cut to fit).

MACT1 Weight: 0.5 lb. (0.23 kg).

MACT1 Dimensions: 6 x 6 x 6 in. (152 x 152

x 152 mm).

MAC1 Air Cell (Volume Cell)• Made of non-corrosive materials

• (2) 1/4-20 stainless steel hex bolts and nuts.

MAC1 Weight: 2 lb. (1 kg).

MAC1 Dimensions: 6 x 6 x 6 in. (152 x 152

x 152 mm).

Dimensions

(1)

(2)

(3)

MACT1 Tube Kit

(Sensor Line)

BLS1

(Bilge

Level

Switch)

MAC1

(Volume Cell)

Optional Mounting Bracket (15050737)

1/2 NPT for electricalconnections

6-5/32 in.(156 mm)

5-1/2 in.(140 mm)

4 feet long(1.21 m) std.

1/4-20 hex bolt(2-places) and nuts

9/32 in. (7 mm) dia.4-places

3-1/4 in.(83 mm)

5-3/16 in.(132 mm)

2-3/8 in.(60 mm)

1-1/2 in.(38 mm)

BLSK-95107BRevised 10-03

Catalog Section 15(00-02-0052)Bilge Level Switch System

Typewritten text
ISSDistribution.com - Call (800) 333-7976
Typewritten text
ISSDistribution.com - Call (800) 333-7976
Page 39: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

Installation Instructions

1. Select a mounting location in lower part of the bilge

for the MAC1 air cell, but do not mount cell at this

time. MAC1 must be placed so that no debris will

become trapped inside it. Position the air cell

approximately 1-1/2 to 2 in. (38 to 51 mm) below

desired operation point and note location for attach-

ing the cell to a stringer or bulkhead, etc. Vertical

adjustment may be necessary for final calibration

(see step 6).

2. Mount the BLS1 switch via optional mounting

bracket 15050737 or one of your supply. Keep the

BLS1 switch within 4 ft. (1.21 m) off the MAC1 air

cell. Tubing must NOT have a loop or flat area for

moisture to collect. Always maintain a downward

slope.

3. Attach the MACT1 tubing kit to the air cell and to

the BLS1 switch. Any tubing can be used as long as

it does not corrode and it provides air tight connec-

tions.

4. Wire the SPDT snap-switch according to instruc-

tions and your requirements. See typical wiring dia-

grams, below.

5. The BLS1 trip point is preset to operate when bilge

level rises approximately 1-1/2 in. (38 mm) above the

bottom of the air cell. It will reset when level falls

approximately 3/4 in. (19 mm).

6. Raise or lower the air cell so that the distance from

the hull to the trip point level on the side of the air

cell is equal to desired level of bilge. Secure the air

cell via the 2 hex bolts.

If necessary, adjustment can be made prior to

installation by placing the air cell in a bucket of

water and adjusting the white knurled knob inside

the BLS1 until the snap-switch actuates at the

desired level. Or, build a coffer dam around the air

cell in the bilge, add the desired amount of bilge

water, and adjust the switch trip knob as explained

above. BE SURE to remove coffer dam prior to

placing the BLS1 into service.

7. Verify proper operation at desired levels prior to

launch.

NOTE: The air cell will automatically recharge itself

anytime the bilge level falls below the air cell.

CAUTION: Air cell tubing and connections mustremain air tight. Seal any holes placed in the air cell.

WARNINGBefore beginning installation of this Murphy product:

4Disconnect ALL electrical power to the machine.4Make sure the machine CANNOT operate during

installation.4Follow all safety warnings of the machine manufacturer.4Read and follow all installation instructions.

AIR

Sensor Line(MACT1 Tube Kit)

BLS1 Bilge Level Switch

BLS1 Switch

BLS1 Switch

CustomerSuppliedBracket

ST Series Alarm

Volume Cell(MAC1)

Bulkhead

OptionalMountingBracket(15050737)

1234

56AB

ABAB

ABAB

8–30 VAC

NO

C NC

8–40 VDC

Power Supply

+ve –ve

Alarm #5

Alarm #1

Alarm #2

Alarm #3

Alarm #4

+

NO

C NC

K-1

K-1

See Note

NOTE: Contact rating should beappropriate for horse power of the pump.

OperatingBilge Pump

Base ModelBLS1 = Bilge level switchBLSK1 = Bilge level switch kit:

BLS1 (Bilge Level Switch) MACT1 (Tubing kit)MAC1 (Air cell)

Body (Lid and Case)Blank = Aluminum

SwitchBlank = SPDT, 5A

Accessories and Replacement Parts (order separately)15050737: BLS1 mounting bracket.

15010205: 5 A snap-switch and movement assembly.

15000123: Diaphragm assembly.

15050823: Piston.

15050824: Knob for limit adjustment.

How to Order the BLSK1To order use the model number designation diagram below.

Typical Installation and Wiring

BLSK1

BLSK-95107B page 2 of 2

CONTROL SYSTEMS & SERVICES DIVISIONP.O. Box 1819; Rosenberg, Texas 77471; USA+1 281 633 4500 fax +1 281 633 4588 e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336Villahermosa Office +52 993 3162117e-mail [email protected]

FRANK W. MURPHY, LTD.Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.+44 1722 410055 fax +44 1722 410088 e-mail [email protected]

MURPHY SWITCH OF CALIFORNIA41343 12th Street WestPalmdale, California 93551-1442; USA+1 661 272 4700 fax +1 661 947 7570e-mail [email protected]

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MACQUARRIE CORPORATION1620 Hume HighwayCampbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558e-mail [email protected]

FW Murphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA

+1 918 317 4100

fax +1 918 317 4266

e-mail [email protected]

www.fwmurphy.com

RE

GISTER

ED

USA–ISO 9001:2000 FM 28221UK–ISO 9001:2000 FM 29422

Printed in U.S.A.

WarrantyA limited warranty on materials and workmanship is given with this FW Murphy product.

A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

Page 40: $5-0( - Instrument Sales & Service, Inc · 2019. 6. 24. · wired as a closed-loop system, resulting in a reliable fault-sensi-tive circuit. How the LM500 Maintains Levels. As crankcase

16427 NE AIRPORT WAY, PORTLAND, OREGON 97230ISSPARTS.COM • WWW.INSTRUMENTSALES.COM

CATALOG

TO PLACE AN ORDER CONTACT OURSALES REPRESENTATIVE TODAY!

Rectangle
Rectangle
Typewritten text
WWW.ISSDISTRIBUTION.COM
Typewritten text
Call - (800) 333-7976