Patented self cleaning semi-open channel impeller, ideal f or pumping inwaste water applications. Possible to be upgraded with Guide-pin®f or ev en better clogging resistance. Modular based design with highadaptat ion grade.
Head
272 226mm272 226mm
62.9%
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
[f t]
0 100 200 300 400 500 600 700 [US g.p.m.]
Pump
Frequency
Motor
Rated v oltage
-
Rated power
Rated speed
Number of poles
Rated current
400 V50 Hz
29.5 hp
2
2930 rpm
39 A
NP 3171 SH 3~ 272
Motor #
3~
Suction Flange Diameter
c ale S
Dr awn
Reg no
Dat e by Chec k ed
by
DRAWING
AUTOCAD
Denom inat ion
Dimensional drwg
**2 3/4/ 3/4
8"
4"
2"/3" GUIDE BARS
**3 3/8/5 5/16
15 3
/4
**12
5/8
/10
1/4
2"
2 3/4
12"
3 3/
8 8"
8"
6 5/
8
BOLT â̂… 3/4(4x)
9 7/8
45°
6 5/8
**30 1/8/32 1/8
8"
39 1
/2
4 9/16
9 3/4
**22"/24"
18 3/4
NP,FP 3171 SH
Z
Z-Z
Z
MIN
LE
VE
L
(TO FURTHEST POINT)
2" GUIDEBARS FOR NEW INSTALLATION
3" GUIDEBARS FOR RETROFIT
* DIMENSIONS TO END OF GUIDEBARS
**DIMENSIONS FOR 2"/3" GUIDEBARS
REF. LINE
CL
OF
DIS
CH Weight
6926800 4
5399
080304KST W
Ø4 "
(lbs)
Pump Disch 95 765
REF.LINE
REF.LINE
41"
Ø4"
Impeller diameter 226 mmNumber of blades 2
N3171.181 25-18-2AA-W 22KWStator v ariant 2
Phases
Starting current 280 A
Technical specification
Note: Picture might not correspond to the current configuration.
Power f actor
Ef f ic iency
1/1 Load3/4 Load1/2 Load
1/1 Load3/4 Load1/2 Load
0.910.880.81
90.0 %91.5 %91.5 %
100 mmCurve according to: ISO 9906 grade 2 annex 1 or 2
P - Semi permanent, WetInstallation:
Configuration
Impeller material Grey cast iron
General
Discharge Flange Diameter 3 15/16 inch
Water, pure
Last updateCreated on
2014-05-23
Created byProject IDProject
Head
EfficiencyTotal efficiency
Shaft power P2Power input P1
NPSH-values
272 226mm272 226mm
62.9%
172 ft
59.8 %
54.1 %
28.6 hp
31.5 hp
12.4 ft 391 US g.p.m.
272 226mm272 226mm
172 ft
59.8 %
54.1 %
28.6 hp
31.5 hp
12.4 ft 391 US g.p.m.
272 226mm272 226mm
172 ft
59.8 %
54.1 %
28.6 hp
31.5 hp
12.4 ft 391 US g.p.m.
272 226mm (P2)272 226mm (P2)
172 ft
59.8 %
54.1 %
28.6 hp
31.5 hp
12.4 ft 391 US g.p.m.
272 226mm (P1)272 226mm (P1)
172 ft
59.8 %
54.1 %
28.6 hp
31.5 hp
12.4 ft 391 US g.p.m.
272 226mm272 226mm
172 ft
59.8 %
54.1 %
28.6 hp
31.5 hp
12.4 ft 391 US g.p.m.
0102030405060708090
100110120130140150160170180190200210220230240250260
[ft]
01020304050
[%]
10
15
20
25
30
[hp]
5101520253035[ft]
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 [US g.p.m.]
Motor #
50 Hz
Phases 3~
400 VNumber of poles 2
Rated power 29.5 hp
Starting currentRated current 39 A
Rated speed 2930 rpm
N3171.181 25-18-2AA-W 22KWStator variant
Number of blades 2
Power factor
NP 3171 SH 3~ 272
Suction Flange Diameter
Performance curve
Pump
Impeller diameter 87/8"
Motor
Rated voltage
280 A
Efficiency
1/1 Load3/4 Load1/2 Load
1/1 Load3/4 Load1/2 Load
Frequency2 0.91
90.0 %
0.880.81
91.5 %91.5 %
100 mm
Curve according to: ISO 9906 grade 2 annex 1 or 2
Discharge Flange Diameter 3 15/16 inch
Water, pure
Last updateCreated on
2014-05-23
Created byProject IDProject
Head
272 226mm
62.9%
172 ft
391 US g.p.m.05
101520253035404550556065707580859095
100105110115120125130135140145150155160165170175180185190195200205210215220225230235240245250255260265
[ft]
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 [US g.p.m.]
1
NP 3171 SH 3~ 272Duty Analysis
Curve according to: ISO 9906 grade 2 annex 1 or 2
Indiv idual pump Total
1 391 US g.p.m. 172 ft 28.6 hp 391 US g.p.m. 172 ft 28.6 hp 59.8 % 1000 kWh/US MG 12.4 ft
Pumps running Specific /System Flow Head Shaft power Flow Head Shaft power Hyd eff. energy NPSHre
Water, pure
Last updateCreated on
2014-05-23
Created byProject IDProject
Head
EfficiencyTotal efficiency
Shaft power P2Power input P1
NPSH-values
272 226mm272 226mm
62.9%
45 Hz45 Hz
62.9%
40 Hz40 Hz
62.9%
35 Hz35 Hz
62.9%
30 Hz30 Hz
62.9%
272 226mm272 226mm45 Hz45 Hz40 Hz40 Hz35 Hz35 Hz30 Hz30 Hz272 226mm272 226mm45 Hz45 Hz40 Hz40 Hz35 Hz35 Hz30 Hz30 Hz
272 226mm (P2)272 226mm (P2)
45 Hz45 Hz
40 Hz40 Hz
35 Hz35 Hz30 Hz30 Hz
272 226mm (P1)272 226mm (P1)45 Hz45 Hz40 Hz40 Hz35 Hz35 Hz30 Hz30 Hz
272 226mm272 226mm
45 Hz45 Hz
40 Hz40 Hz
35 Hz35 Hz
30 Hz30 Hz
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
[ft]
0
10
20
30
40
50
[%]
-5
0
5
10
15
20
25
30
[hp]
5
10
15
20
25
30
35
[ft]
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 [US g.p.m.]
NP 3171 SH 3~ 272VFD Curve
Curve according to: ISO 9906 grade 2 annex 1 or 2Water, pure
Last updateCreated on
2014-05-23
Created byProject IDProject
Head
272 226mm
62.9%
172 ft
391 US g.p.m.
45 Hz
62.9%
40 Hz
62.9%
35 Hz
62.9%
30 Hz
62.9%
05
101520253035404550556065707580859095
100105110115120125130135140145150155160165170175180185190195200205210215220225230235240245250255260265
[ft]
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 [US g.p.m.]
1
NP 3171 SH 3~ 272VFD Analysis
Curve according to: ISO 9906 grade 2 annex 1 or 2
Indiv idual pump Total
1 50 Hz 391 US g.p.m. 172 ft 28.6 hp 391 US g.p.m. 172 ft 28.6 hp 59.8 % 1000 kWh/US MG12.4 ft1 45 Hz 353 US g.p.m. 140 ft 21 hp 353 US g.p.m. 140 ft 21 hp 59.8 % 1080 kWh/US MG10.5 ft1 40 Hz 314 US g.p.m. 111 ft 14.7 hp 314 US g.p.m. 111 ft 14.7 hp 59.8 % 1170 kWh/US MG8.73 ft1 35 Hz 275 US g.p.m. 84.8 ft 9.86 hp 275 US g.p.m. 84.8 ft 9.86 hp 59.8 % 1300 kWh/US MG7.05 ft1 30 Hz 235 US g.p.m. 62.3 ft 6.21 hp 235 US g.p.m. 62.3 ft 6.21 hp 59.8 % 1470 kWh/US MG5.51 ft
Pumps running Specific /System Frequency Flow Head Shaft power Flow Head Shaft power Hyd eff. energy NPSHre
Water, pure
Last updateCreated on
2014-05-23
Created byProject IDProject
NP 3171 SH 3~ 272Dimensional drawing
cale S
Drawn
Reg no
Date by Checked
by
DRAWING AUTOCAD
Denomination
Dimensional drwg
**2 3/4/ 3/4
8"
4"
2"/3" GUIDE BARS
**3 3/8/5 5/16
15 3
/4
**12
5/8
/10
1/4
2"
2 3/4
12"
3 3/
8 8"
8"
6 5/
8
BOLT ∅ 3/4(4x)
9 7/8
45°
6 5/8
**30 1/8/32 1/8
8"
39 1
/2
4 9/16
9 3/4
**22"/24"
18 3/4
NP,FP 3171 SH
Z
Z-Z
Z
MIN
LE
VE
L
(TO FURTHEST POINT)
2" GUIDEBARS FOR NEW INSTALLATION
3" GUIDEBARS FOR RETROFIT
* DIMENSIONS TO END OF GUIDEBARS
**DIMENSIONS FOR 2"/3" GUIDEBARS
REF. LINE
CL
OF
DIS
CH Weight
6926800 4
5399
080304KST W
Ø4"
(lbs)
Pump Disch 95 765