V.RZQZ Guangdong Chigo Heating & Ventilation Equipment Co,.ltd. Note All the data in this catalogue maybe changed without notice for further improvement on quality and performance. 86-757-88781037 Helangsha,Chigo industrial district,lishui,nanhai,foshan, guangdong,china,P.C:528244 [email protected] www.chigo-cac.com 86-757-88789825 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER

50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

V.RZQZ

Guangdong Chigo Heating & Ventilation Equipment Co,.ltd.

NoteAll the data in this catalogue maybe changed without notice for further improvement on quality and performance.

86-757-88781037

Helangsha,Chigo industrial district,lishui,nanhai,foshan,guangdong,china,P.C:528244

[email protected]

www.chigo-cac.com

86-757-88789825

50Hz/60Hz INVERTERLIGHT COMMERCIALAIR CONDITIONER

Page 2: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

About

Honored of National high-tech enterprises

2012

Chigo commercial air conditioning division established

2004

Full DC inverter VRF CMV-X series launched

2014 2017

Mechanical and ElectricalInstallation Level 2 Qualification

2019

GCHV starts operating independently from Chigo Holding

Guangdong Chigo Heating & Ventilation Equipment Co,.ltd. Established

2011 Chigo enter central air conditioning industry

2002 New R&D office building and VRF plant put into operation

2013 2015 Honored of Provincial engineeringresearch and development center

“”

2018 2018 Russia World Cup HVAC SupplierTest center certificated by CNAS

Established in 2011,Guangdong Chigo Heating & Ventilation Equipment Co,.Ltd. ( GCHV ) is a professional central air conditioning equipment manufacture and supply enterprise integrating R&D,testing,manufacturing, marketing,projectdesign,sales and after sales service.GCHV covers an area of 167,000 square meters,with more than 120,000 square meters of plants and 14 modern first class production lines.

GCHV’s annual output of central air conditioners exceeds 2 million sets, which including VRF,modular chiller,light commercial air conditioners,air source heat pumps and other products.GCHV’s products are in great demand on 100 countries and regions and has accomplished thousands of reference projectsworldwide,which enabled it become the top 3 central air conditioner supplier in china.

Page 3: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

GCHV has established a strict and scientific quality management system with supplier quality assurance,incoming quality control,process quality control and final quality control to ensure the highest quality of the products.

Production Capacity

QualityManagement

Key Components

100% Pre-check

Quality Assurance

1% Inspection

Key Step Control

Assembly

Assembly

On-line Testing

1%Inspection

Finished Products

ISO9001 quality management system, ISO14001 environmental management system, OHSAS18001 occupational health and safety management system,QC080000 electronic and electrical components and products harmful substances process management system certification

GB/T 19001 24001 ISO9001 ISO14001 OHSAS18001 QC080000

AGV System

MES System

Robotic Assembly Arm

Automatic Packing Robot

GB/T 19001

GB/T 24001

Main product certificated by CCC, energy-saving certification, ETL, AHRI,DOE, CE, CB, SASO,ESMA, MEW and others.

GCHV has 14 advanced production lines and an annual production capacity of over 1.5 million sets.

Introduce lean production management, improve production efficiency. By the use of various robots ,AGV system and other equipment, improving the online, offline process, optimizing the logistics distribution technology, improving product qualityand production efficiency.Adopts MES(Manufacturing Execution System) system, it helps a lot in tracking production schedule, inventory status, work schedule and other operations management to improve. Product quality and productivity.

Quality Superiority Certification

The industry-leading testing center has beencertified by CNAS in 2018, With a full range ofprofessional incoming inspection labs,enthalpydifference labs , EMC labs, 27 national accreditedlabs for testing and verification.

Page 4: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

R&D Strength

Enthalpy Difference Lab

EMC Lab Professional Engineers

200HP Long-term Running Lab Modular Chiller Test Lab

DirectoryDC Inverter Mono LCAC Universal Outdoor Unit

How To Read The Model

60Hz DC Inverter Mono LCAC Universal Unit

DC Inverter Multi Split Unit

Controllers

01

03

1 7

3 1

36

Laboratory Control Room

200kg Transport Simulation Platform

Noise Test Lab

Electromagnetic Vibration Lab

The R&D center of GCHV has more than 200 technical engineers.And carry out technology collaboration and joint research with postdoctoral research workstations and Guangdong enterprise workstations,at the same time, introducing senior technical experts from Japan to join GCHV and served as senior technical consultants, GCHV pay great attention in R&D and invest 4.5% of annual income every year to develop new technology,by continuous innovation,GCHV has established a solid development foundation and strength in performance,structure, electronic control, industrial design and other professional aspects.

The test center covers an area of more than 6,000 square meters. It has a series of industry-leading professional laboratories. In 2010, it passed the consistency check of the National Energy Efficiency Label Management Center and obtained certificate,in 2018,the test center obtained CNAS national certification .

Page 5: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

(R32) (R410a) (R32/R410a)

D:Full DC Inv

(R32 Only) (R410a Only)

12 000,

DC Inverter Mono LCAC

Compact 4 way cassette

60,000

; R4:R32

; R4:R32

55,000

Page 6: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

12K

New integrated PCB has big contribution to AC fast reply and simple service. Fin type heat sink gives PCB a cool working condition(Single phase ODU).

New electric control box material change from metal to plastic, not only reduce the weight, but also avoid the short circuit cause by the PCB touch the metal box(Single phase ODU).

Energy saving and excellent efficiency,reaching European A++ and A+ class energy label,meets the EU’s new energy efficency requirement.Comply with ErP directive.

Wide outdoor operation range, the cooling operation temperature is down to -15 degree.

-15

COU-12HDR1 COU-18HDR1 COU-24HDR1 COU-36HDR1-A COU-36HZDR1 COU-48HZVR1 COU-60HZVR1

220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50 380~415/3/50 380~415/3/50

Btu/h

KW

Btu/h

KW

dB(A)

mm

mm

kg

g

mm

m

m

°C

°C

Φ6.35/Φ12.7

15(30)

8(20)

-15~50

-15~30

Φ6.35/Φ12.7

15(30)

8(20)

-15~50

-15~30

Φ9.52/Φ15.88

20(50)

10(25)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

12000

1.4-3.5-3.8

11200

1.6-3.3-4.1

DC/Twin-rotary

DC

62

51

900x610x352

990×670×410

33.5/36.5

R410A/1200

AC/Twin-rotary

DC

70

58

950×1335×388

964x1445x402

98.5/106.5

R410A/4100

DC/Twin-rotary

DC

63

52

925×700×366

990×770×410

45/48

R410A/1400

DC/Twin-rotary

DC

67

57

958×843×392

1025×960×430

59/69

R410A/2200

DC/Twin-ratary

DC

68

55

1050×995×347

1145×1120×475

84/95.5

R410A/3800

DC/Twin-rotary

DC

68

55

1050×995×347

1145×1120×475

86.7/97.7

R410A/3800

AC/Twin-rotary

DC

70

58

950×1335×388

964x1445x402

98.5/106.5

R410A/4100

18000

2.0-5.3-5.6

20000

3.0-5.9-6.0

24000

3.5-7.0-8.0

26000

4.5-7.7-8.5

36000

6.6-10.5-12.8

40000

7.35-11.5-13.2

36000

6.6-10.5-12.8

40000

7.35-11.5-13.2

48000

7.15-14.0-15.6

52000

8.0-15.2-17.2

60000

7.8-16.0-17.5

60000

8.5-17.6-19.5

Outdoor power supply(V/N/HZ)

Cooling Capacity

Performance

Physical data

Compressorfan motor

Outdoor noise level

Outdoor unit

Heating Capacity

Refrigerant type/quantity

Piping data

Refrigerantpiping

Ambient temp

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

power level

pressure level

Dimension(W*H*D)

Packing(W*H*D)

Net/Gross weight

Liquid side/Gas side

Max. pipe length

Max. high drop

cooling

heating

COU-18HDR4

220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50 220~240/1/50 380~415/3/50 380~415/3/50

Btu/h

KW

Btu/h

KW

dB(A)

mm

mm

kg

g

mm

m

m

°C

°C

Φ6.35/Φ12.7

15(30)

8(20)

-15~50

-15~30

Φ9.52/Φ15.88

20(50)

10(25)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

Φ9.52/Φ15.88

50(65)

20(30)

-15~50

-15~30

18000

2.0-5.3-5.6

2000

3.0-5.9-6.0

DC/Twin-rotary

DC

63

52

925×700×366

990×770×410

42/45

R32/1300

DC/Twin-rotary

DC

70

58

1014×1430×450

1095×1545×485

112/126.6

R32/3800

DC/Twin-rotary

DC

67

54

958×843×392

1025×960×430

52/62

R32/1700

DC/Twin-rotary

DC

68

55

1030×788×432

1120×900×485

68/74

R32/2150

DC/Twin-rotary

DC

68

55

1030×788×432

1120×900×485

75/81

R32/2150

DC/Twin-rotary

DC

70

58

1014×1430×450

1095×1545×485

109/123.6

R32/3800

DC/Twin-rotary

DC

70

58

1014×1430×450

1095×1545×485

109/123.6

R32/3800

24000

3.5-7.0-8.0

26000

4.5-7.7-8.5

36000

6.6-10.5-12.8

40000

7.35-11.5-13.2

36000

6.6-10.5-12.8

40000

7.35-11.5-13.2

48000

7.0-14.0-15.5

52000

8.0-15.2-16.0

48000

7.0-14.0-15.5

52000

8.0-15.2-16.0

55000

7.5-16.0-17.0

60000

8.5-16.8-17.5

Outdoor power supply(V/N/HZ)

Cooling Capacity

Performance

Physical data

Compressorfan motor

Outdoor noise level

Outdoor unit

Heating Capacity

Refrigerant type/quantity

Piping data

Refrigerantpiping

Ambient temp

power level

pressure level

Dimension(W*H*D)

Packing(W*H*D)

Net/Gross weight

Liquid side/Gas side

Max. pipe length

Max. high drop

cooling

heating

R32 Heat Pump R32

COU-24HDR4 COU-36HDR4 COU-36HZDR4 COU-48HDR4 COU-48HZDR4 COU-55HZDR4

Mono LCAC

48K/55/60K Btu/h

Page 7: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

B

6.1

29.5

35 35

29.5

6.1

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

18K~60K Btu/h

CCA-60HVR1

60,000

CCR-18HVR4

220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

kW

dB(A)

mmmmkg

mm

mm

Φ6.35/Φ12.7

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.15-14.0-15.6 7.5-16.0-17.0

Outdoor power supply(V/N/HZ)

Cooling CapacityPerformance

Physical data

Heating Capacity

Piping data

Diameter

Drain pipe

Power noise level

Pressure noise level

Liquid side/Gas side

R32 Heat Pump Round flow Cassette R32

CCR-24HVR4 CCR-36HVR4 CCR-36HVR4S CCR-48HVR4 CCR-48HVR4S CCR-55HVR4S

dB(A)Body

PanelBodyPanelBodyPanel

Panel Net/Gross weight

Packing(W*H*D)

Net dimension(W*H*D) mmmmmm

EER W/W

Indoor airflow(Hi/Lo/Med) m3/hHeating energy rateCooling energy rate

SEER W/W

COP W/WSCOP W/W

kW

3.35 3.27 3.33 3.33 2.83 2.83 2.716.1 6.1 6.1 6.1 6.1 6.1 6.1

4.01 4.01 3.41 3.41 3.09 3.09 3.084.0 4.0 4.0 4.0 4.0 4.0 4.0

2.5-5.9-6.0 4.5-7.7-8.5 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5

A++ A++ A++ A++ A++ A++ A++A+ A+ A+ A+ A+ A+ A+

900/800/650 1100/1000/850 1800/1700/1550 1800/1700/1550 2000/1800/1600 2000/1800/1600 2000/1900/1700

46~58 56~63 53~61 53~61 54~62 54~62 54~62

36/41/45 43/46/49 43/45/48 43/45/48 45~52 45~52 45~52

840×230×840950×50×950920×265×920

1030×105×103025/306.5/9.5

840×285×840950×50×950920×310×920

1030×105×103030.5/366.5/9.5

840×285×840950×50×950920×310×920

1030×105×103030.5/366.5/9.5

840×230×840950×50×950920×265×920

1030×105×103025/306.5/9.5

840×285×840950×50×950920×310×920

1030×105×103032/37.56.5/9.5

840×285×840950×50×950920×310×920

1030×105×103032/37.56.5/9.5

840×285×840950×50×950920×310×920

1030×105×103032/37.56.5/9.5

R410a Heat Pump 4-way Cassette R410a

Page 8: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

750x95x750 750x95x750 750x95x750

CCB-12HVR1

220~240/1/50

CCB-18HVR1

220~240/1/50

12000 18000Btu/hkW

Btu/hkW

m³/h

dB(A)

Body(mm)Panel(mm)

mmmmmm

Body(kg)

1.4-3.5-3.8 2.0-5.3-5.63.3 3.336.1 6.1A++ A++

11200 200001.6-3.3-4.1 3.0-5.6-6.0

3.5 4.124.04

A+ A+

745x375x675

56044-52

32/36/40565x267x565

65046-55

36/39/43565x267x565

745x375x675

16.5/21.5 16.5/21.5

Φ6.35Φ12.7

DN25

Φ6.35Φ12.7

DN25

Cooling

Heating

Physical data

Piping data

Pipes

Noise level

Indoor unit

Air flow(high speed)

Capacity

EERSEEREnergy class

Capacity

COPSCOPEnergy class

power levelpressure level

Net(W*H*D)

Packing(W*H*D)

Net/Gross weight

Liquid side

Gas sideDrain pipe

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

R410a&R32 Heat Pump R32

CCB-18HVR4

220~240/1/50

180002.0-5.3-5.6

3.416.1A++

200002.5-5.9-6.0

4.084.0A+

745x375x675

65046-55

36/39/43565x267x565

16.5/21.5

Φ6.35Φ12.7

DN25Refrigerant R410a R410a R32

Body(mm)

Panel(mm)

Panel(kg)

650x29.8x650 650x29.8x650 650x29.8x650

2.7/4.0 2.7/4.0 2.7/4.0

Page 9: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

1.59(0.42-2.1)6.1

3.33

5.6(2.5-6.0)1.36(0.5-1.94)

4.12 3.72

6.1 5.1

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

18K~60K Btu/h

CUA-60HVR1

60,000

220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

kW

dB(A)

mm

mm

Φ6.35/Φ12.7

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.0-14.0-15.5 7.5-16.0-17.0

Outdoor power supply(V/N/HZ)

Cooling CapacityPerformance

Physical data

Heating Capacity

Piping data

Diameter

Drain pipe

Power noise level

Pressure noise level

Liquid side/Gas side

R32 Heat Pump R32

dB(A)

Panel Net/Gross weight

Packing(W*H*D)

Net dimension(W*H*D)

EER W/W

Indoor airflow(Hi/Lo/Med) m3/hHeating energy rateCooling energy rate

SEER W/W

COP W/WSCOP W/W

kW

3.23 3.18 3.31 3.31 2.8 2.8 2.696.1 6.1 6.1 6.1 6.1 6.1 6.1

3.86 3.89 3.39 3.39 3.06 3.06 2.904.0 4.0 4.0 4.0 4.0 4.0 4.0

2.5-5.9-6.0 4.5-7.7-8.5 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5

A++ A++ A++ A++ A++ A++ A++A+ A+ A+ A+ A+ A+ A+

900/800/650 1150/1000/850 1800/1650/1500 1800/1650/1500 2000/1700/1600 2000/1700/1600 2000/1700/1600

46~58 53~60 56~65 56~65 58~66 58~66 58~66

36~47 43~49 45~51 45~51 45~52 45~52 46~52

1245×680×240

1325×770×325

35/41

1245×680×240

1325×770×325

35/41

1245×680×240

1325×770×325

35/41

1245×680×240

1325×770×325

34/40

1670×680×245

1750×780×335

49/56

1670×680×245

1750×780×335

49/56

1670×680×245

1750×780×335

49/56

CUA-18HVR4 CUA-24HVR4 CUA-36HVR4 CUA-36HVR4S CUA-48HVR4 CUA-48HVR4S CUA-55HVR4S

DC motor is standard(Except for R410 48K/55K units),operating stably and precisely control for temperature.

Page 10: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

CTA-12HVR1

220~240V/1/50

120003.5(1.4-3.8)

6.1 6.1 6.13.263.33

A++ A++ A++11200

3.3(1.6-4.1)

4.0 4.04.12 3.72

4.0

3.5A+ A+

1214X210X467

1310X240X510 1310X240X510

1214X210X467

A+

6000-3042-5231-40

814x210x46716

910x240x51019

Φ6.35Φ12.7DN25

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.*: We suggest that for 18K&24K units, external static pressure is lower than 30Pa. If higher static pressure is needed, please contact with supplier.

V/N/Hz

6.1

A++

4.04.0A+

1214X210X467

1310X240X510

6.13.26A++

3.34.0

1310X240X510

1214X210X467

A+

220~240V/1/50 220~240V/1/50 220~240V/1/50 220~240V/1/50

CTA-18HVR1 CTA-18HVR4 CTA-24HVR1 CTA-24HVR4

5.9(2.5-6.0) 7.7(4.5-8.5)

1030

R410a&R32 Heat Pump R32

Refrigerant R410a R410a R32 R410a R32

1214mm

Short body,1214mm length,easy to install,low noise and light weight,suitable for hotel room.

92030(0-60) 0-30 30(0-100)

Page 11: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

3.10(1.2-4.25)4.0

A+

51 51

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.*: We suggest that for 36K units, external static pressure is lower than 80Pa and for 48K&55K units, external static pressure is lower than 120Pa. If higher static pressure is needed, please contact with supplier.

V/N/Hz

36K~60K Btu/h

CTB-60HVR1

60,000

220~240/1/50

kW

dB(A)

mm

mm

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

Φ9.52/Φ15.88

DN25

6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.0-14.0-15.5 7.5-16.0-17.0

Outdoor power supply(V/N/HZ)

Cooling CapacityPerformance

Physical data

Heating Capacity

Piping data

Diameter

Drain pipe

Rated power noise level

Static pressure range

Liquid side/Gas side

R32 Heat Pump R32

Pa

Panel Net/Gross weight

Packing(W*H*D)

Net dimension(W*H*D)

EER W/W

Indoor airflow(Hi/Lo/Med) m3/hHeating energy rateCooling energy rate

SEER W/W

COP W/WSCOP W/W

kW

3.21 3.21 2.8 2.8 2.76.1 6.1 6.1 6.1 6.1

3.3 3.3 3.0 3.0 3.04.0 4.0 4.0 4.0 4.0

7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5

A++ A++ A++ A++ A++A+ A+ A+ A+ A+

1900/1690/1130 1800/1500/1200 2500/2350/1980 2500/2350/1980 2500/2350/1980

55~63 55~63 56~64 56~64 56~64

0-120 0-120 0-160 0-160 0-160

1425×260×643

1490×325×720

46/50

1279×307×830

1395×380×920

49/56

1279×307×830

1395×380×920

49/56

1425×260×643

1490×325×720

46/50

1279×307×830

1395×380×920

49/56

CTB-36HVR4 CTB-36HVR4S CTB-48HVR4 CTB-48HVR4S CTB-55HVR4S

220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

World famous brand DC motor is standard(Optional for R410 48K/55K units),save energy and control the room temperature more prercisely.

50Pa ESP design for medium static pressure duct ,duct connected installation meet for different roomstructure (can be customized to 70Pa ESP).For R32 medium duct type, the static pressurecan be high to120Pa.

Page 12: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

48K~60K Btu/h

CTH-60HVR1

60,000

(Can be customized to 150Pa ESP)

Page 13: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

Mono LCAC

V/N/Hz

60Hz R410a Heat Pump

COU-12HNVR1-COutdoor unit

Power supply

Cooling capacity

Heating capacity

208~230/1/60

120003.5

120003.5

DC/Rotary≤51

843×304×540920×335×585

25.9/28.2R410a/920

Φ6.35/Φ12.72510

-15~50-15~30

CompressorOutdoor noise level

Outdoor unitNet(W×H×D)Packing(W×H×D)Net/Gross weight

Refrigerant type/quantity

Refrigerantpiping

Liquid/Gas sideMax.pipe lengthMax.high dropCoolingHeating

Ambient temp.

V/N/Hz

Btu/hkW

Btu/hkW

dB(A)mmmmkgg

mmmm℃

COU-18HNVR1-C

208~230/1/60

180005.3

180005.3

DC/Rotary≤53

843×304×540920×335×585

29.5/31.8R410a/1150Φ6.35/Φ12.7

2515

-15~50-15~30

COU-24HNVR1-C

208~230/1/60

240007.0

240007.0

DC/Twin-rotary≤54

890×352×609990×410×660

36.1/39.4R410a/1600Φ6.35/Φ12.7

2515

-15~50-15~30

COU-36HNVR1-C

208~230/1/60

3600010.5

3600010.5

DC/Twin-rotary≤58

970×370×7701100×470×880

69.0/74.0R410a/2500

Φ9.52/Φ15.883020

-15~50-15~30

COU-48HNVR1-C

208~230/1/60

4800014.0

4800014.0

DC/Twin-rotary≤58

970×370×7701100×470×880

69.0/74.0R410a/3000

Φ9.52/Φ15.885025

-15~50-15~30

COU-60HNVR1-C

208~230/1/60

6000016.0

6000016.0

DC/Twin-rotary≤58

911×400×1330964×402×1445

98.5/106.5R410a/3600

Φ9.52/Φ15.885025

-15~50-15~30

COU-60HXVR1-C

208~230/3/60

6000016.0

6000016.0

DC/Twin-rotary≤58

911×400×1330964×402×1445

98.5/106.5R410a/3600

Φ9.52/Φ15.885025

-15~50-15~30

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

12K 48K/60K Btu/h

Page 14: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

60Hz R410a Heat Pump

CCA-18HNVR1-CIndoor unit

Power supply

Cooling

Heating

208~230/1/60

5.32.45.32.6

1250≤58

840×230×840950×50×950920×265×920

1030×105×103025/305.4/8.0

Φ6.35/Φ12.7DN25

Indoor air flowIndoor noise level

Indoor unit

Net(W×H×D)

Packing(W×H×D)

Net/Gross weight

V/N/Hz

kWW/WkW

W/W

m3/hdB(A)

Body(mm)Panel(mm)Body(mm)Panel(mm)Body(kg)Panel(kg)

mmmm

CCA-24HNVR1-C

220~240/1/60

72.37

2.6

1250≤63

840×230×840950×50×950920×265×920

1030×105×103025/305.4/8.0

Φ6.35/Φ12.7DN25

CCA-36HNVR1-C

208~230/1/60

10.52.610.53.4

1600≤63

840×285×840950×50×950920×310×920

1030×105×103027/325.4/8.0

Φ9.52/Φ15.88DN25

CCA-48HNVR1-C

208~230/1/60

142.5142.8

1900≤65

840×285×840950×50×950920×310×920

1030×105×103029.5/355.4/8.0

Φ9.52/Φ15.88DN25

CCA-60HNVR1-C

208~230/1/60

162.3162.7

1900≤65

840×285×840950×50×950920×310×920

1030×105×103029.5/355.4/8.0

Φ9.52/Φ15.88DN25

CCA-60HNVR1S-C

208~230/1/60

162.3162.7

1900≤65

840×285×840950×50×950920×310×920

1030×105×103029.5/355.4/8.0

Φ9.52/Φ15.88DN25

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

18K~60K Btu/h

Capacity

EERCapacityCOP

Refrigerant liquid/gas pipingDrainage pipe

Page 15: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

CCB-12HNVR1-C

208~230/1/60

CCB-18HNVR1-C

208~230/1/60

Cooling

Heating

Physical data

Piping dataRefrigerant Liquid/Gas side pipingDrainage pipe

Indoor air flow(high speed)Indoor noise level

CapacityInputRated currentEERCapacityInputRated currentCOP

Net(W*H*D)

Packing(W*H*D)

Net/Gross weight

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

60Hz R410a Heat Pump

21/22

Indoor unit

kWkWA

W/WkWkWA

W/W

m3/hdB(A)

Body(mm)Panel(mm)Body(mm)Panel(mm)Body(kg)Panel(kg)

mmmm

3.51.15

52.403.50.88

43.20

560≤52

580×260×580650×30×650745×375×675750×95×750

16.5/21.52.7/4.0

Φ6.35/Φ12.7DN25

5.31.88

2.405.31.657.5

2.60

650≤55

580×260×580650×30×650745×375×675750×95×750

16.5/21.52.7/4.0

Φ6.35/Φ12.7DN25

Page 16: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

23/24

V/N/Hz

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

60Hz R410a Heat Pump

18K~60K Btu/h

Heating

Capacity

EER

Capacity

COP

kW

W/W

kW

W/W

m3/h

dB(A)

mm

mm

kg

mm

mm

Indoor air flow(high speed)

Indoor noise level

Dimension(W×H×D)

Packing(W×H×D)

Net/Gross weight

Refrigerant liquid/gas side

Drainage pipe

CUA-18HNVR1-C

208~230/1/60

5.3

2.4

5.3

2.6

700

≤58

1245×680×247

1325×770×325

34/40

Φ6.35/Φ12.7

DN25

CUA-24HNVR1-C

208~230/1/60

7.0

2.3

7.0

2.6

900

≤60

1245×680×247

1325×770×325

34/40

Φ6.35/Φ12.7

DN25

CUA-36HNVR1-C

208~230/1/60

10.5

2.6

10.5

3.4

1300

≤60

1245×680×247

1325×770×325

36/42

Φ9.52/Φ15.88

DN25

CUA-48HNVR1-C

208~230/1/60

14.0

2.5

14.0

2.8

2000

≤65

1670×680×247

1750×770×325

49/55.5

Φ9.52/Φ15.88

DN25

CUA-60HNVR1-C

208~230/1/60

16.0

2.3

16.0

2.7

2000

≤65

1670×680×247

1750×770×325

49/55.5

Φ9.52/Φ15.88

DN25

CUA-60HNVR1S-C

208~230/1/60

16.0

2.3

16.0

2.7

2000

≤65

1670×680×247

1750×770×325

49/55.5

Φ9.52/Φ15.88

DN25

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

Page 17: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

CTA-12HNVR1-C

208~230V/1/60

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

60Hz R410a Heat Pump

1214mm

Short body,1214mm length,easy to install,low noise and light weight,suitable for hotel room.

25/26

kW

kW

A

W/W

kW

kW

A

W/W

m3/h

dB(A)

mm

mm

kg

mm

mm

3.5

1.15

5.2

2.80

3.5

0.88

4

3.20

620

≤37

814×210×467

910×240×510

14/17

Ф6.35/Ф12.7

DN25

Capacity

Input

Rated current

EER

Capacity

Input

Rated current

COP

Cooling

Heating

Physical data

Indoor air flow(high speed)

Indoor noise level

Net(W×H×D)

Packing(W×H×D)

Net/Gross weight

Indoor unit

Piping data

Refrigerant liquid/gas side pipe

Drainage pipe

208~230V/1/60

5.3

1.8

8.2

2.74

5.3

1.65

7.5

2.60

750

≤58

1010×210×467

1310×240×510

21/24

Ф6.35/Ф12.7

DN25

208~230V/1/60

7.0

2.45

11.1

2.70

7.0

2.05

8.5

2.60

800

≤63

1214×210×467

1310×240×510

25/28

Ф6.35/Ф12.7

DN25

CTA-18HNVR1-C CTA-24HNVR1-C

Page 18: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

27/28

World famous brand DC motor is standard(Optional for R410 48K/55K units),save energy and control the room temperature more prercisely.

50Pa ESP design for medium static pressure duct ,duct connected installation meet for different roomstructure (can be customized to 70Pa ESP).For R32 medium duct type, the static pressurecan be high to120Pa.

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

Medium ESP Ducted Unit60Hz R410a Heat Pump

CTB-36HVR1-C

208~230V/1/60V/N/Hz

kW

kW

A

W/W

kW

kW

A

W/W

m3/h

dB(A)

mm

mm

kg

mm

mm

10.5

3.4

15.5

2.73

10.5

2.8

12.5

3.40

1150

≤63

1170×260×643

1255×325×720

33/37

Ф9.52/Ф15.88

DN25

Capacity

Input

Rated current

EER

Capacity

Input

Rated current

COP

Cooling

Heating

Physical data

Indoor air flow(high speed)

Indoor noise level

Net(W×H×D)

Packing(W×H×D)

Net/Gross weight

Indoor unit

Piping data

Refrigerant liquid/gas side pipe

Drainage pipe

208~230V/1/60

14.0

4.5

20.5

2.70

14.0

4.0

17.5

2.80

2000

≤65

1425×260×643

1490×325×720

45/51

Ф9.52/Ф15.88

DN25

208~230V/1/60

16.0

6.5

12.5

2.30

16.0

5.5

12.0

2.70

2000

≤65

1425×260×643

1490×325×720

45/51

Ф9.52/Ф15.88

DN25

CTB-48HVR1-C CTB-60HVR1-C

Page 19: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

48K~60K Btu/h

(Can be customized to 150Pa ESP)

V/N/Hz

kW

W/W

kW

W/W

m3/h

dB(A)

mm

mm

kg

mm

mm

Capacity

EER

Capacity

COP

Cooling

Heating

Physical data

Indoor air flow(high speed)

Indoor noise level

Net(W×H×D)

Packing(W×H×D)

Net/Gross weight

Indoor unit

Piping data

Refrigerant liquid/gas side pipe

Drainage pipe

208~230V/1/60

16.0

2.3

16.0

2.70

2300

≤66

1175×370×625

1245×445×655

47/51

Ф9.52/Ф15.88

DN25

CTH-60HVR1S-C

Notes: 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB; 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.4.The above data may be changed without notice for future improvement on quality and performance.

36/48/60k Btu/h

Capacity

Capacity

Indoor Input

Indoor Rated current

Indoor air flow

ESP

Indoor noise level

Unit (WxHxD)

Packing (WxHxD)

Net

Gross

Operation temperature range

Operation Control Wired controller

Indoor dimension

Indoor weight

V/N/Hz

Btu/h

W

W

A

Pa

dB(A)

mm

mm

kg

kg

208~230/1/60

36000

10500

253

1.16

1700

37

51~56

460×774×520

520×834×565

37

39

16-32

2500

50

51~57

500×970×550

45

48

16-32

2200

50

51~57

500×970×550

560×1030×595

45

48

16-32

208~230/1/60

48000

14068

470

2.14

208~230/1/60

60000

16000

470

2.14

Model CAH-36CNVR1 CAH-48CNVR1 CAH-60CNVR1

29/30

Page 20: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

220~240/1/50220~240/1/50220~240/1/50

7+77+9

9+99+12

7+7+77+9+918+7

9+9+912+9+9

18+9

7+7+7+712+12+9

18+1224+7

9+9+9+912+12+12

18+1824+12

9+9+9+9+912+12+12+9

18+12+1224+18

7000-14000 7000-18000 7000-21000 7000-27000 7000-28000 7000-36000 7000-420001280 1650 1930 2472 2520 3400 39005.56 7.3 8.4 10.9 11.2 15.2 18.03.2 3.2 3.2 3.2 3.2 3.2 3.26.6 6.3 6.5 6.3 6.8 6.8 6.5

8000-16000 8000-20000 8000-24000 8000-30000 8000-30000 8000-38000 8000-440001350 1730 2150 2600 2450 3080 3650

6.4 7.97 10.8 10.8 11.2 15.2 18.03.5 3.4 3.4 3.4 3.63 3.6 3.554.0 4.0 4.0 4.0 4.0 4.0 4.0

54 54 55 55 59 61 62944×608×345 944×608×345 989×843×392 989×843×392 1090×997×399 1090×997×399 1090×997×399995×680×415 995×680×415 1025×960×430 1025×960×430 1145×1120×475 1145×1120×475 1145×1120×475

41/44 41/44 53.7/64.1 56.1/66.6 77.7/89.1 82.6/94 84.5/95.9

2×(6.35/9.52) 2×(6.35/9.52) 3×(6.35/9.52) 3×(6.35/9.52) 4×(6.35/9.52) 4×(6.35/9.52) 5×(6.35/9.52)30 30 45 45 60 60 7510 10 10 10 10 10 10

-15~52 -15~52 -15~52 -15~52 -15~52 -15~52 -15~52

2×(10~15) 2×(12~18) 3×(12~18) 3×(12~18) 4×(10~15) 4×(12~18) 5×(12~18)-15~34 -15~34 -15~34 -15~34 -15~34 -15~34 -15~34

220~240/1/50

84.5/95.9

31/32

V/N/Hz

77.7/89.1

~

82.6/94

~

R32

220~240/1/50V/N/Hz

R32 Multi Split Outdoor UnitC2OU-14HDR4-A C2OU-18HDR4-A C3OU-21HDR4-A C3OU-27HDR4-A C4OU-28HDR4-A C4OU-36HDR4-A C5OU-42HDR4-A

220~240/1/50220~240/1/50220~240/1/50R410a Units

R32 Units

Ambient temperature(Cooling)Ambient temperature(Cooling)

52°C

34°C

Page 21: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

33/34

V/N/Hz V/N/Hz

R32R32

V/N/Hz

CSG-07HVR4-A CSG-09HVR4-A CSG-12HVR4-A CSG-18HVR4-A CSG-24HVR4-A220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

7000 9000 12000 18000 2400040 40 40 60 660.2 0.2 0.2 0.27 0.3

8000 10000 13000 19000 2500040 40 40 60 660.2 0.2 0.2 0.27 0.3

400/350/320 500/400/320 550/400/330 750/580/500 1000/900/700

30/27/24 33/28/24 36/30/25 44/40/36 45/42/3847 47 50 58 60

878×290×227950×365×300

878×290×227950×365×300

878×290×227950×365×300

953×347×2701075×380×310

1180×362×288 1235×390×330

8.5/11 8.5/11 8.5/11 10.5/13.5 13.5/16.5

6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7 9.52/15.88DN20 DN20 DN20 DN20 DN20

10~15 12~18 16~23 23~34 34~51

R32R32

V/N/Hz

CSC-07HVR4-A CSC-09HVR4-A CSC-12HVR4-A CSC-18HVR4-A220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

7000 9000 12000 1800025 25 26 34

0.12 0.12 0.12 0.16

8000 10000 13000 1900025 25 26 34

0.12 0.12 0.12 0.16

540/490/410 540/490/410 690/610/520 790/710/610

39/36/33 39/36/33 40/37/34 44/41/3850 50 54 55

565×267×565745×375×675

565×267×565745×375×675

565×267×565745×375×675

565×267×565745×375×675

16.5/21.5 16.5/21.5 16.5/21.5 16.5/21.5

6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7DN25 DN25 DN25 DN25

10~15 12~18 16~23 23~34

Page 22: 50Hz/60Hz INVERTER LIGHT COMMERCIAL AIR CONDITIONER · 2020. 5. 5. · Full DC inverter VRF CMV-X series launched 2014 2017 Mechanical and Electrical Installation Level 2 Qualification

35/36

V/N/Hz

R32R32

V/N/Hz

CST-07HVR4-A CST-09HVR4-A CST-12HVR4-A CST-18HVR4-A220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

7000 9000 12000 1800020 20 30 450.1 0.1 0.15 0.2

8000 10000 13000 1900020 20 30 450.1 0.1 0.15 0.2

550/410/340 550/410/340 680/580/450 800/700/600

30/26/23 30/26/23 36/31/27 32/30/2647 47 52 48

814×210×467910×240×510

814×210×467910×240×510

814×210×467910×240×510

1010×210×4671110×240×510

17/19.5 17/19.5 17/19.5 20.5/24

6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7DN25 DN25 DN25 DN25

10~15 12~18 16~23 23~34