Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
MagPro coils
Versatility in Magnetic Stimulation
VMMMMMM aaaaaggggggggggggVVVVentureeeeentureentureeentureVVVVV For Clinical and Research use
2
Selection Criteria for Magnetic Stimulating Coils
Large, or Small Coils – circular or figure of 8?
Large coils provide a high penetration depth, but are not
very focused. The small coils are more focused, but have a
relatively shallow penetration depth. Thus there is an inverse
relation between penetration depth and focus.The coils
come in many sizes and shapes. The two most commonly
used coils are the circular shaped coil and the butterfly
shaped coil also known as the “figure of 8” coil.
Circular or Parabolic Coils
When applying the circular or parabolic coil, the induced
current in the tissue occurs under the windings. A fairly large
area of body tissue will be stimulated.
The circular or parabolic coil may be positioned
conveniently over many parts of the body, and usually serves
well as a “general purpose coil”.
Butterfly Coils
The Butterfly coils are more focused in comparison with the
circular coils. The two windings are placed side-by-side or
overlapping, enabling the coil to stimulate structures with
focus right under its center. The butterfly coil is useful in
focused stimulation.
List of MagVentures standard coils with basic facts. More detailed informations at www.magventure.com
Model Type
Coil Winding
Diameter
Magnetic
Gradient
Number of
pulses before
warm-up Applications
MC-125 Circular Coil 114 mm 41 kT/s 450 pulses General Purpose,
Phrenic nerve roots,
Motor Cortex
C-100 Circular Coil
Built-in amplitude
control
110 mm 35 kT/s 400 pulses General Purpose,
Phrenic nerve roots,
Motor Cortex
MMC-140 Parabolic Coil 120 mm 33 kT/s 650 pulses General Purpose,
Motor Cortex,
Deep-lying nerves
MMC-140-II Parabolic Coil
Built-in amplitude
control
126 mm 33 kT/s 650 pulses General Purpose,
Motor Cortex,
Deep-lying nerves
gggggVgMMMMMM aaaaagggggggggggggVVVVentureeeeentureentureeentureVVVVV
3
Model Type
Coil Winding
Diameter
Magnetic
Gradient
Number of
pulses before
warm-up Applications
MC-B35 2 x 45 mm 50 kT/s 75 pulses Peripheral nerves
High focus stimula-
tion
Low penetration
depth
MC-B70 Figure-of-8 Coil
Bend outer windings
provide +10% power
2 x 97 mm 31 kT/s 400 pulses Foc. Stimulations,
Deep-lying nerves,
Motor Cortex,
Peripheral nerves
C-B60 Figure-of-8 Coil
Built-in amplitude
control
2 x 75 mm 35 kT/s 350 pulses Foc. Stimulations,
Motor Cortex,
Peripheral nerves
D-B80 Figure-of-8 Coil
120° angled
2 x 80 mm 31 kT/s 350 pulses Foc. Stimulations,
Motor Cortex,
Peripheral nerves
MC-B65-HO
2 : 2m cable
8 : 8m cable
Figure-of-8 Coil
Orthogonal handle
2 x 75 mm 35 kT/s 350 pulses Foc. Stimulations,
Motor Cortex,
Peripheral nerves
RT-120 Elliptic coil (racetrack
coil)
Inner loop
ø30x110mm
Outer loop
ø80x160mm
31 kT/s 1500 pulses General Purpose
Bigger muscles
Spinal nerves
RT-120-II Elliptic coil (racetrack
coil) with built in
amplitude control.
Inner loop
ø30x110mm
Outer loop
ø80x160mm
31 kT/s 1500 pulses General Purpose
Bigger muscles
Spinal nerves
MMMMMMMM aaaaaaggggggggggggggggggVVVVentureeeeentureentureeentureVVVVV
4
Model Type
Coil Winding
Diameter
Magnetic
Gradient
Number of
pulses before
warm-up Applications
MCF-75 Small circular Coil
Static fluid Cooling
65 mm 43 kT/s 500 pulses Peripheral nerves,
Motor Cortex
MCF-125 Standard circular Coil
Static fluid Cooling
120 mm 34 kT/s 2000 pulses Train stimulation,
Brain tissue,
Deep-lying nerves
MCF-B65 Figure-of-8 Coil
Static fluid Cooling
2 x 75 mm 32 kT/s 2000 pulses Train stimula-
tion, Brain tissue,
Deep-lying nerves
Model Type
Coil Winding
Diameter
Magnetic
Gradient
Number of
pulses before
warm-up Applications
Cool-B65 Figure-of-8 Coil
Dynamic fluid Cooling
2 x 75 mm 36 kT/s 20000 pulses Train protocols,
Long train stimula-
tion, Brain tissue,
Deep-lying nerves
When the highest number of stimulations are required dy-
namic cooling is required.
The cool unit in combination with the Cool-B65 coil are
the solution if a long duration and high stimulation output is
required.
Cool unit required for
MagVenture Cool-B65 coil.
Dynamic cooled coils – Coils with external cooling
Static cooled coils. To prevent fast overheating during use
we developed the static cooled F-series of coils. The fluid
absorbes dissipated energy thus enabling more stimulis.
F coils – Static cooled coils
VMMMMMM aaaaagggggggggggggVVVVentureeeeentureentureeentureVVVVV
5
MagVenture placebo coils are geometrical identical with the
corresponding normal coils.
Placebo coil are intended for blind testing and have consid-
erable lower magnetic fields than the normal coils.
MagVenture develops special coils for special purposes. Many
coils have been developed. Examples MRi-B88 for use in MR
scanners and the Twin Coil for Magnetic Seizure Therapy
(together with the special MagPro MST stimulator)
Besides our standard coils we manufactures custom designed
coils based on specifications from our customers.
Placebo coils
Special coils
Custom designed coils
Model Type
Coil Winding
Diameter
Magnetic
Gradient
Number of
pulses before
warm-up Applications
MC-P-B70 Figure-of-8 Coil
Placebo Coil
2 x 100 mm Magnetic
field at-
tenuation
> 80%
400 pulses Placebo version of
MC-B70
MC-P-B65 Figure-of-8 Coil
Placebo Coil
2 x 75 mm Magnetic
field at-
tenuation
> 80%
1600 pulses Placebo version of
MCF-B65
gggggVgMMMMMM aaaaaggggggggggggVVVVentureeeeentureentureeentureVVVVV
6
Additional accessoriesAccessories such as Remote control, MEP monitor, Cable for
external trig, Flexible arm, Flight case for the MagPro, Mag-
Probe, 110/230V power supply for the MagPro etc. are also
supplied by MagVenture. Please see MagVenture on
www.magventure.com for further details.
General coil features.All coils are designed for use with Magpro R30, X100, R30
with option, X100 with option and R100.
Coils with build in power control in the coil handle and
trigger button in the handle can also be used with a MagPro
Compact. (coil C-100, C-B60, RT 120-II and MMC-140-II)
Coils without built in power control and trigger button
requires the coil converter when connected to a MagPro
Compact.
#5426 w
ww.dan
ske-ideselskab
.dk
Cable for
Pro, Mag-
c. are also
on
-140-II)
utton
MagPro
VERSATILITY IN MAGNETIC STIMULATION
North America
Please note that not all coils are cleared for sale by FDA in the US.
For further details of which are cleared in the US, please contact local MagVenture distributor
MMMM aaaaggggggggggggVVVVentureeeeentureentureeentureVVVVVLucernemarken 15 · DK-3520 Farum · Denmark
Phone: +45 4499 8444 · Fax: +45 4439 0449
E-mail: [email protected] · www.magventure.com