HERION 26230, 80100 SERIES Indirect solenoid actuated spool valves
6 & 12 mm orifice (ND) 3/2, 5/2, 5/3, G1/4, G1/2
Standard manual override withdetent
Compact design
High flow rate
Simple design of soft spool sealsystem
Maintenance-free
Easily interchangeable solenoidand softseal spool
TECHNICAL DATAMedium:
Compressed air, filtered,lubricated and non-lubricated
Operating pressure:
1 ... 10 bar
Flow direction:
Fixed
Mounting position:
Optional, preferably with solenoidon top
Ambient temperature:
Depending on solenoid system
-10°C ... 50°CFor temperatures below 0°C use conditioned dryair. If installed outdoors protect all connectionsagainst the penetration of moisture.
Consult our Technical Service for use below +2°C.
Electrical connection:
Connector interface to DIN 43650form B
Connector interface to DIN EN175301-803 form A and B
G1/4 1 10 *3) 1200 < 5 (1) 8010750xxxx***** *2) C00220828 C02470828 T40C2800 0680003 0570275
3/2 mono NC G1/2 1,5 10 *3) 3000 < 5 (2) 8010850xxxx***** *2) C00221228 C02471228 T40C4800 0680003 0570275
G1/4 1 10 *3) 1200 < 5 (1) 8012750xxxx***** *2) C00220828 C02470828 T40C2800 0680003 0570275
3/2 mono NO G1/2 1,5 10 *3) 3000 < 5 (2) 8012850xxxx***** *2) C00221228 C02471228 T40C4800 0680003 0570275
3/2 bi G1/4 1 10 1200 < 5 (3) 8011750xxxx***** C00220828 C02470828 T40C2800 0680003 0570275
G1/4 1 10 *3) 1200 < 5 (5) 2623000xxxx***** *2) C00220828 C02470828 T40C2800 0680003 0570275
5/2 mono G1/2 2 10 *3) 3000 < 5 (6) 2623500xxxx***** *2) C00221228 C02471228 T40C4800 0680003 0570275
G1/4 1 10 1200 < 5 (7) 2623100xxxx***** C00220828 C02470828 T40C2800 0680003 0570275
5/2 bi G1/2 2 10 3000 < 5 (8) 2623600xxxx***** C00221228 C02471228 T40C4800 0680003 0570275
G1/4 3 10 900 < 5 (9) 2623200xxxx***** C00220828 C02470828 T40C2800 0680003 0570275
5/3 - COE G1/2 2,5 10 2200 < 5 (10) 2623700xxxx***** C00221228 C02471228 T40C4800 0680003 0570275
G1/4 3 10 900 < 5 (9) 2623300xxxx***** C00220828 C02470828 T40C2800 0680003 0570275
5/3 - APB G1/2 2,5 10 2200 < 5 (10) 2623800xxxx***** C00221228 C02471228 T40C4800 0680003 0570275
5/3 - COP G1/4 3 10 900 < 5 (9) 2623400xxxx***** C00220828 C02470828 T40C2800 0680003 0570275
G1/4 2 8 *3) 1200 < 2 (1) 8010751xxxx***** *2) C00220828 C02470828 T40C2800 0680003 0570275
3/2 mono NC G1/2 2 8 *3) 3000 < 2 (2) 8010851xxxx***** C00221228 C02471228 T40C4800 0680003 0570275
G1/4 2 8 *3) 1200 < 2 (5) 2623001xxxx***** *2) C00220828 C02470828 T40C2800 0680003 0570275
5/2 mono G1/2 2 8 *3) 3000 < 2 (6) 2623501xxxx***** *2) C00221228 C02471228 T40C4800 0680003 0570275
G1/4 2 8 1200 < 2 (7) 2623101xxxx***** C00220828 C02470828 T40C2800 0680003 0570275
5/2 bi G1/2 2 8 3000 < 2 (8) 2623601xxxx***** C00221228 C02471228 T40C4800 0680003 0570275
Actuation Port size Operating pressure (bar)min. max.
MODELSSilencer
ACCESSORIES
All types with manual override.xxxx Insert solenoid codes from table below ***** Insert voltage codes from table below.*2) Port 3 is not throttleable *3) Stagnation pressure at R . operating pressure -1 bar.APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure.
Power drawn (W)
Flow(l/min)
Drawingno.
Straight fitting
Elbow fitting
Basic plugForm B
Basic plugForm A
3-189
Solenoid actuators
4,8 8,5 – – IP 00 -40 ... +50 11 1 30521,7 4,3 – – without connector, 3050
IP 65 with connector*
Form B *6)
4,5 8,0 – – IP 00 -40 ... +50 12 1 30301,6 3,5 – – without connector, 3036
IP 65 with connector*
Form A *6)
– 2,1 – – Cat. II2G, EEx m II T5 -20 ... +50 13 8 3063
3 m cable *2)
5,0 – – – Cat. II2G, EEx m II T4 -20 ... +50 13 1 3060
3 m cable *2)
– 5,0 – – Cat. II2G, EEx m II T4 -20 ... +50 13 8 3061
3 m cable *2)
* Connector not supplied, Order No.: form A 0570275, form B 0680003, DIN EN 1753301-803.*2) Certificate of Conformity PTB No. 03 ATEX 2015 X.Valves and solenoids can only be combined if their electrical ratings correspond with each other (see table »General information«).For valve with power consumption < 5 watt please use 4,8 or 4,5 watt solenoids.For valve with power consumption < 2 watt please use 1,7 or 1,6 watt solenoids.Standard voltages 24 V DC, 230 V AC. Further versions on request.
Power consumption Rated current at
24V DC W
230V ACVA
24V DCmA
230V ACmA
Circuit diagramno.
Drawing no. Solenoidcodes
DIMENSIONS
Valve dimensions
D
C
E
P
12
3
S
R
B
L
HK
A
J
FG
141
1 2
1 G1/4 115,5 55 41 7 11 24 7,5 24,5 27 23 5,5 5 30
2 G1/2 143,5 65 46 9,5 29 33 31,5 – 46 50 7 2,5 35
Drawing no. A B C D E F G H J K L Ø P R S
Voltage codes
Voltage Code
24 V d.c. 02400
24 V a.c. 02450
230 V a.c. 23050
Without coil 00000
1 Manual override
Protection classfluid max.
Temperatureambient/fluid °C
3-190
HERION 26230, 80100 SERIES Indirect solenoid actuated spool valves6 & 12 mm orifice (ND) 3/2, 5/2, 5/3, G1/4, G1/2
D
C
E
12
3
P
S
R
B
L
HK
A
12
J FG
141
1
3 G1/4 186,5 55 41 7 81,5 24 78 95 27 93,5 5,5 5 30
4 G1/2 195,5 65 46 9,5 81 33 81 – 46 100,5 7 2,5 35
Drawing no. A B C D E F G H J K L Ø P R S
5 G1/4 139,5 55 40 7,5 35 24 – 5 – 67 12 7 5 30
6 G1/2 171,5 65 46 9,5 59,5 33 30 16 46 60 13 7 3 35
Drawing no. A B C D E F G H J K L M Ø P R S
3
5
1
4
2
14
D
C S
RE
B
P
M
G
K
L
H
A
GG
F
J
1
1 Manual override
1 Manual override
43
5 6
3-191
Solenoid dimensions
Circuit diagrams
3
5
1
4
2
14
12
D
C
S
RE
D1
B
P
M
G
K
L
H
A
GG
F
1
1
29
65 12
11
29,5
22
Ø9
36
15
72 12
29,5
30
Ø9
29
29
,52
2
~ 56
7 G1/4 214,5 55 40 40 7,5 107,5 24 77,5 67 – 12 7 5 30
8 G1/2 223,5 65 46 46 9,5 112 33 82,5 46 60 13 7 3 35
9 G1/4 232,5 55 40 40 7,5 118 24 88 67 – 12 7 5 30
10 G1/2 289 70 46 50 10 144,5 33 – 50 60 16,5 7 4 40
Drawing no. A B C D D1 E F G H K L M Ø P R S
1 Manual override
1 Solenoid actuators
4x90° turnable
7 10
11 12
81
13
...
www.norgren.com/info/en3-192
For further information
3-192
3/2 or 5/2 way function via adapterplates
Exhaust air recirculation
Crossover-free switching,switchover function guaranteedeven with small cross section airsupply
Rest position in the event of powerfailure (monostable design)
Manual override with detent
Compact design
Simple design soft seal spoolsystem
Easily interchangeable solenoid
HERION 97100 SERIES Indirect solenoid actuated spool valvesfor single and double acting actuators with NAMUR interface
6 mm orifice (ND) - 3/2, 5/2, 5/3, NC/APB, G1/4
MODELS
Symbol Port size1 3 (5) 2, 4
Function Actuation Flowl/m
kg Drawing no.
TECHNICAL DATAMedium:
Compressed air, filtered,lubricated and non-lubricated
Mounting position:
Optional
Operating pressure:
2 ... 8 bar
Flow direction:
Fixed
Ambient temperature:
Valve: -25°C ... +50°CSolenoid: See solenoid tableWith minus temperatures, use conditioned dryair. If installed in the open protect all connectionsagainst the penetration of moisture
Consult our Technical Service for use below +2°C.
Electrical connection:
Acc. to DIN 175301-803 form A
MATERIALSHousing: aluminium anodized
Pilot flange: plastic (PBT)
Seals: NBR (Perbunan)
3/2, 5/2 & 5/3 VALVES
35 1
4 2
14 12
4 2
15 3
12 10 12 14
513
4 2
4 2
15 3
12 14
513
4 21410
G1/4 G1/8 Flange NC Sol/Spring 750 0,25 1 9710000xxxx*****
G1/4 G1/8 Flange NC Sol/Sol 750 0,35 2 9711000xxxx*****
G1/4 G1/8 Flange APB Sol/Sol 500 0,40 3 9712000xxxx*****
Alternative models - NPT Ports
xxxx Insert solenoid codes from table on next page.***** Insert voltage codes from table on page 3-194.APB = All Ports Blocked.Exterior free of non-ferrous metals.
3-193
G1/4 G1/8 Flange NC Sol/Spring 750 0,25 1 9710002xxxx*****
G1/4 G1/8 Flange NC Sol/Sol 750 0,35 2 9711002xxxx*****
G1/4 G1/8 Flange APB Sol/Sol 500 0,40 3 9712002xxxx*****
1,6 3,5 – IP 65 (with connector) -40 ... +50 5 1 3036
DIN EN 175301-803
Form A*6)
2 – II3G EEx nA II T5 -15 ... +50 5 1 3046
II3D IP65 T 95°C
with connector
DIN EN 175301-803
Form A
– 4,0 II3G EEx nA II T5 -15 ... +50 5 8 3047
II3D IP65 T 95°C
with connector
DIN EN 175301-803
Form A
2,7 – II2G EEx m II T5 -20 ... +50 6 1 3062 *3)
Stranded wire, 3 m long
– 2,1 II2G EEx m II T5 -20 ... +50 6 8 3063 *3)
Stranded wire, 3 m long
2,7 – – IP 66 Connection M12x1 -10 ... +50 7 8 3071
DIN EN 60947-5-2
Power consumption
24 V d.c.(W)
230 V a.c.(VA)
SOLENOID ACTUATORS 3/2, 5/2 & 5/3 valves
MODELS
Symbol Port size1 3 (5) 2, 4
Function Actuation Flowl/m
kg Drawingno.
35 1
4 2
14 12
12 14
513
4 2
3/2, 5/2 & 5/3 VALVES for minimal electrical power, incl. EEx i
4 2
15 3
12 10
xxxx Insert solenoid codes from table on next page.***** Insert voltage codes from table on next page.APB = All Ports Blocked.Exterior free of non-ferrous metals.
Standard voltages 24 V DC, 230 V AC. Other voltages on request.For intrinsically safe circuits, protection class EEx ia IIC T6.*3) Certificate of Conformity PTB No. PTB 03 ATEX 2015X.*6) Connector is not included in delivery; Required connector 0570275.
4 2
15 3
12 10 12 14
513
4 2
Circuit diagramno.
Drawing no.
Solenoidcodes
Protection class
Ex protectioncategory
Temperatureambient/fluid
°C
3-194
1,7 – – – – IP 65 (with connector) -40 ... +50 4 1 3050
DIN EN 175301-803
Form B *6)
0,7 0,7 *2) – – – IP 65 (with connector) *6) -40 ... +50 5 1 3034
DIN EN 175301-803
Form A *6)
2 – – – II3G EEx nA II T5 -15 ... +50 5 1 3046
II3D IP65 T 95°C
with connector
2,7 – 115 – II2G EEx m II T5 -20 ... +50 6 1 3062 *3)
Connector
with 3 m cable
– 2.1 *2) – 9 *2) II2G EEx m II T5 -20 ... +50 6 8 3063 *3)
Connector
with 3 m cable
2,7 – 115 – – IP 66 Connection M12x1 -10 ... +50 7 8 3071
DIN EN 60947-5-2
Power consumption Rated current at
24 V d.c.(W)
230 V a.c.(VA)
24 V d.c.(W)
230 V a.c.(VA)
SOLENOID ACTUATORS 3/2, 5/2 & 5/3 valves for minimal electrical power
275 37 330 12,3 T6 -40 ... +80 T6 +70 8 13 3039 *4)
T4 -40 ... +80 T4 +85
Nom. resistanceRN coil( )
For intrinsically safe circuits, protection class EEx ia IIC T6/T4
Voltage codes
Voltage Code
24 V d.c. 0240024 V a.c. 02450230 V a.c. 23050
0014500 (G1/8)* 0570275 Form A 0612790 NAMUR single connection plate 05405930663303 with rectifier 0612791 NAMUR-slot use in combination with 0612790 ( Alu)0680003 Form B
ACCESSORIES
HERION 97100 SERIES Indirect solenoid actuated spool valves
for single and double acting actuators with NAMUR interface6 mm orifice (ND) - 3/2, 5/2, 5/3, NC/APB, G1/4
Standard voltages 24 V DC, 230 V AC. Other voltages on request.Design acc. to VDE 0580, EN50014/50028. 100% duty cycle.
When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account.On the other hand, the low effective inductivity and capacity can be ignored.*2) Valves can be operated with DC only. For 230V AC application please use 206V DC coil together with recifier plug 0663303*3) Certificate of Conformity PTB No. PTB 03 ATEX 2015X.*4) Certificate of Conformity PTB 03 Atex 2134 PTP 03 IEC 2166, CSA - Certificate No. LR 51090-4, FM approved.Required connector acc. to DIN EN 17031-801 form A or ISO 4400. Installation acc. to requirements of FM and CSA.*6) Connector is not included in delivery; required connector for DC: type 0680003 Form B, type 0570275 Form A.
* For indoor use
Ex Protectioncategory
Protectionclass
Temperatureambient/fluid°C
Drawingno.
Circuitdiagramno.
Solenoidcodes
Fluid temperaturemax.°C
Drawingno.
Circuitediagramno.
Solenoidcodes
Ambienttemperature°C
Required voltageat terminalRw 50
ResistanceRw 50
Required switchingcurrent (mA)
Silencer Connectors Flange plate Yoke
3-195
31
5
42
01
01
M5
3
5.5
19.5
13
25 7.2
37.2
32
40
G 1
/4G
1/8
24
1295
.5
1818
110
203
3/2 resp. 5/2 way function can be achieved just by swapping enclosed adaptor plates.Make sure Marker and Arrow do match as shown on above drawing. Original mode ofsupply: 5/2 function.
CONVERSION INSTRUCTIONS
OF 5/2 INTO 3/2 WAY FUNCTION
3/2
67
5/2
67
5/2 way function (original mode of supply)
3/2 way function
DIMENSIONS
Valve dimensions
Solenoid dimensions
24
13
5
01
M5
3
5.5
19.5
13
25 7.2
37.2
32
40
G 1
/4G
1/8
24
1224
.4
20.5
56.5
38.5
131.
5
36
15
72 12
29,5
30
Ø9
29
65 12
11
29,5
22
Ø9
29
29
,52
2
~ 56
29,5
38,5 10
14,5
29,5
M12
x1
12
34
39
14,5
72 12
29,5
30
Ø9
Circuit diagrams NAMUR hole pattern
M5
32
2
24
3
3
5
4
2
1
4 5 6
1
13
8
7 8
2 3
5
4
3
2 Port 2 (A)
Coding stud threaded
M5 (10 deep)
Port 3 (R)
7
6 Arrow
Marker
2 4
13 5
�
0 1
01
M5
3
5.5
19.5
13
257.
2
37.2
32 40
G 1/4 G 1/8
24
12 78.8
1818
93.2
186.3
www.norgren.com/info/en3-196
For further information
3-196
For single and double actingactuators
Crossover-free switching, switch-over function guaranteed even withsmall cross section air supply
Rest position in the event of powerfailure provided (monostabledesign)
3/2 or 5/2 way function in one valve
Manual override with detent
Compact design
Solenoid valves are applicable inprotection class EEx m and EEx ia,for zones 1, 2 (gases) ATEX cat.II 2G, EEx nA, for zones 2 (gases), 22(dust) ATEX cat.II 3 GD
TECHNICAL DATAMedium:
Filtered, lubricated or non-lubricated
and dry compressed air *1)
Operation:
Solenoid, indirectly controlled
HERION 97300 SERIES Indirect solenoid actuated soft sealspool valves with NAMUR interface
3/2, 5/2 - G1/4
MODELS
Symbol Port size *1)
3,5 2, 4Actuation Flow
(l/min)Drawing no.
Flow direction:
Fixed
Mounting position:
Optional
Port size:
G1/4, 1/4 NPT
Electrical connection:
See solenoid table
Operating pressure:
2 ... 8 bar
Temperature:
Valve: -5°C* ... +50°C*Consult our Technical Service for use below +2°C.
Solenoid:
See solenoid table
MATERIALSHousing: Aluminium anodized
Pilot flange: Plastic (PBT)
Flange plate: Aluminium
Seals: NBR (Perbunan)
*1) Oil recommendation: Shell Hydrol DO 32,ESSO Febis K 32 (as of July 1992) or comparableoils with DVI-values < 8 (DIN 53521) and ISOviscosity class 32-46 (DIN 51519).
G1/4 G1/4 Flange Solenoid/Spring 2 ... 8 1300 1 97300001/4 NPT 1/4 NPT Flange 9730010
G1/4 G1/4 Flange Solenoid/Solenoid 2 ... 8 1300 2 97310001/4 NPT 1/4 NPT Flange 9731010
3/2, 5/2 directional valves5/2 way or 3/2 way function (see conversion instructions page 3-198)
4 2
15 3
12 10
12 14
513
4 2
4 2
15 3
12 10
12 14
513
4 2
*1) When ordering please indicate solenoid, voltage and current type (frequency).Outside free of nonferrous metals.
Operatingpressure (bar)
3-197
1,7 4,3 – IP 65 (with connector) -40 ... +50 4 1 3050
DIN EN 175301-803
Form B *6)
1,6 3,5 – IP 65 (with connector) -40 ... +50 5 1 3036
DIN EN 175301-803
Form A *6)
2 – II3G EEx nA II T5 -15 ... +50 5 1 3046
II3D IP65 T 95°C
with connector
DIN EN 175301-803
Form A
– 4,0 II3G EEx nA II T5 -15 ... +50 5 8 3047
II3D IP65 T 95°C
with connector
DIN EN 175301-803
Form A
2,7 – II2G EEx m II T5 -20 ... +50 6 1 3062 *3)
Stranded wire, 3 m long
– 2,1 II2G EEx m II T5 -20 ... +50 6 8 3063 *3)
Stranded wire, 3 m long
2,7 – – IP 66 Connection M12x1 -10 ... +50 7 8 3071
DIN EN 60947-5-2
Power consumption
24 V d.c.(W)
230 V a.c.(VA)
SOLENOID ACTUATORS
Standard voltages 24 V DC, 230 V AC. Other voltages on request.*3) Certificate of Conformity PTB No. PTB 03 ATEX 2015X.*6) Connector is not included in delivery; Required connectors 068003 form B or 0570275 form A.
OPTIONS SELECTOR 973★ 0★ 0 .★ ★ ★ ★ .★ ★ ★ .★ ★
Solenoid actuators Substitute
See table
Voltage Substitute
24 V d.c. 024.00
230 V a.c. 230.50
Function Substitute
5/2 way, spring return (3/2 way spare adaptorplate supplied) 0
5/2 way, solenoid return (3/2 way spare adaptorplate supplied) 1
Port size Substitute
G1/4 0
1/4 NPT 1
Ex protectioncategory
Protectionclass
Temperatureambient/fluid°C
Circuitdiagramno.
Solenoidcodes
Drawingno.
3-198
275 42 330 12,3 T6 -40 ... +80 T6 +70 8 13 3039 *4)
T4 -40 ... +80 T4 +85
For intrinsically safe circuits, protection class EEx ia IIC T6/T4
0014600 (G1/4)* 0570275 form A 0612790 Single connection plate 05405930663303 form A with rectifier 0612791 NAMUR-slot use in combination with 0612790 (Alu)0680003 form B
ACCESSORIES
Please note - when ordering the intrinsically safe coil please use default voltage code 00000.When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in to account.On the other hand, the low effective inductivity and capacity can be ignored.
*4) Certificate of Conformity PTB 03 Atex 2134 PTP 03 IEC 2166, CSA -Certificate No. LR 51090-4, FM approved.Required connector acc. to DIN EN 17031-801 form A or ISO 4400. Installation acc. to requirements of FM and CSA.Connector is not included in delivery; required connector: type 0570275 form A.
* For indoor use
3/2 resp. 5/2 way function can be achieved just by swapping enclosed adaptor plates.Make sure Marker and Arrow do match as shown on above drawing. Original mode ofsupply: 5/2 function.
CONVERSION INSTRUCTIONS
OF 5/2 INTO 3/2 WAY FUNCTION
3/2
67
5/2
67
5/2 way function (original mode of supply)
3/2 way function
Arrow
Marker7
6
HERION 97300 SERIES Indirect solenoid actuated soft seal spool valves
with NAMUR interface3/2, 5/2 - G1/4
Fluid temperaturemax. °C
Drawingno.
Circuitediagramno.
Solenoidcodes
Ambienttemperature°C
Required voltageat terminalRw 50
ResistanceRw 50
Required switchingcurrent (mA)
Nom. resistanceRN coil( )
Silencer Connectors Flange plate Yoke
3-199
DIMENSIONS
Valve dimensions
ˇ 5,5
M 5
24101
20132
46,5
31
2422,5 22,5
63
30
43
7,2 3
ø 5,5
M 5
2433
145,5
32
46,5
31
2422,5 22,5
45
30
43
7,2 3
19
12 12
34,5
104
2127ø 9 ø 14,5
25,5 M 5
41
25,5
1616
M 5
11,5
19
1012
29
35
3019
ø 5,5 ø 9,5 G 1/4
19
G 1
/4
19
41
60°
11
51
9,5
512
5,5
5,5
Single connection plate
Type: 0612790
NAMUR slot
Type: 0612791
4
3
2
1 Manual override
Solenoid operator
Coding stud
Port size G1/4 or 1/4 NPT
21
29,5
38,5 10
14,5
29,5
M12
x1
12
34
3-200
Yoke
Type: 0540593
205
12
65
2x
50 M 5
41
Solenoid dimensions
4 5
6 7
36
15
72 12
29,5
30
Ø9
29
65 12
11
29,5
22
Ø9
29
29
,52
2
~ 56
HERION 97300 SERIES Indirect solenoid actuated soft seal spool valves
with NAMUR interface3/2, 5/2 - G1/4
3-201
39
14,5
72 12
29,5
30
Ø9
8
NAMUR hole pattern
M5
32
2
24
3
3
5
4
2
Circuit diagrams
13
81
5
4
3
2 Port 2 (A)
Coding stud threaded
M5 (10 deep)
Port 3 (R)