DESCRIPTION UNIT660 MW AT

BMCR5000 MW AT

BMCR

S/H STEAM FLOW T/HR 2225 1625

SH STEAM PR KG/CM2 256 178

SH STEAM TEMP 0C 540 540

RH STEAM FLOW T/HR 1742 1397.4

RH STEAM TEMP INLET 0C 299

340

RH STEAM TEMP OUTLET 0C 568

540

RH STEAM PRESS OUTLET KG/CM2 46.61

41.9

FEED WATER TEMP 0C 289.64 255

PR. DROP IN SH SYSTEM KG/CM2 49.2 17

PR. DROP IN RH SYSTEM KG/CM2 1.69 2.1

PARAMETERS

Page 3: 660MW vs 500MW. DESCRIPTIONUNIT 660 MW AT BMCR 5000 MW AT BMCR S/H STEAM FLOWT/HR2225 1625 SH STEAM PRKG/CM 2 256 178 SH STEAM TEMP 0C0C540 RH STEAM FLOWT/HR1742

1. NO DRUM

2. ECONOMISER BANKS & O/L HEADER

3. TWO STAGES OF REHEATER

4. FINAL SUPER HEATER (COUNTER FLOW)

5. MAIN STEAM & HRH O/L HEADERS

6. SPIRAL WALL

7. VERTICAL BUCK STAYS

8. ELECTRO HYDRAULIC SAFETY VALVES

9. BA HOPPERS 6 NOS.

10. ESP PASSES 6 NOS.

11. AXIAL ID FANS

12. LDO & HFO SYSTEMS

13. BOILER FILLING ONLY THROUGH ECO FEED LINE

14. OXYGENATED WATER TREATMENT

PHYSICAL

Page 4: 660MW vs 500MW. DESCRIPTIONUNIT 660 MW AT BMCR 5000 MW AT BMCR S/H STEAM FLOWT/HR2225 1625 SH STEAM PRKG/CM 2 256 178 SH STEAM TEMP 0C0C540 RH STEAM FLOWT/HR1742

DESCRIPTION 500 MW 660 MW

ECONOMISER SA210Gr A1 SA210Gr C

WATER WALL SA210Gr C SA213T22

DRUM/SEPERATOR SA299 SA302C

LTSH SA213T11 SA213T11,23,91

DIVISIONAL SH SA213T11,22,91

FINAL SH SA213 T22,91and TP347H

SA213T11,23,91, 92

LTRH SA213T11,22 SA210GrC, SA213T12, 23

FINAL RH SA213 T22,91

and TP347H

SA213T23,91,

Super304H

SH OUTLET HEADER SA335P22 SA335P91

RH OUTLET HEADER SA335P22 SA335P23, P91

MATERIALS

Page 5: 660MW vs 500MW. DESCRIPTIONUNIT 660 MW AT BMCR 5000 MW AT BMCR S/H STEAM FLOWT/HR2225 1625 SH STEAM PRKG/CM 2 256 178 SH STEAM TEMP 0C0C540 RH STEAM FLOWT/HR1742

SECTION MATERIAL

Economizer Tubes SA210C

Evaporator Tubes

Spiral SA213T22

Vertical SA213T22

Superheater

Tubes

Primary SA213T23, T91

Secondary SA213T12, T23, T91

Final SA213T23, T91, T92

Reheater

Tubes

Primary SA210C, T12, T23

Final SA213T23, T91, SUPER304H

Separators SA302C

Headers SH outlet SA335P91

RH outlet SA335P91

Material Oxidation Criteria ℃

SA-210C 454

SA-213T2 482

SA-213T12 552

SA-213T22 593

SA-213T23 593

SA-213T91 649

SA-T92 649

SUPER304H 760

PRESSURE PARTS MATERIALS :