DESCRIPTION
6U 6-Slot VPX Backplane 1” Pitch Information Page Number Connector pin-out tables for each slot type 2 Connector pin-out tables and part numbers for all cable connectors 3 Tables showing power connections and current ratings 3 Tables showing jumper locations and jumper functions 4 Optional terminations and default termination information (if applicable) 4 Standard Technical Documentation: 6U 6 Slot VPX Backplane 1
Citation preview
6U 6-Slot VPX Backplane1” Pitch
TABLE OF CONTENTS
Information Page NumberConnector pin-out tables for each slot type 2Connector pin-out tables and part numbers for all cable connectors 3Tables showing power connections and current ratings 3Tables showing jumper locations and jumper functions 4Optional terminations and default termination information (if applicable)
4
Fabric connection diagram (if applicable), along with this information in a tabular form 5Illustrations showing locations of all slot connectors, keys as well as power connections, cable connectors and jumpers
6 & 7
Standard Technical Documentation: 6U 6 Slot VPX Backplane
1 877 HYBRICON WWW.HYBRICON.COM1
*Slot 6 Power Only
CONNECTOR PINOUT TABLES
Connector Pin Out Tables (VPX Slots)
J0 Row A Row B Row C Row D Row E Row F Row G Row H Row I1 VS2 VS2 VS2 VS2 VS1 VS1 VS1 VS12 VS2 VS2 VS2 VS2 VS1 VS1 VS1 VS13 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS34 GND NVMRO SYSREST* GND -12 VAUX GND SM3 SM2 GND5 GND SM1 SM0 GND +3.3 VAUX GND GND6 GND GND GND +12 VAUX GND GND7 GND GND GND GND8 GND GND RES_BUS+ RES_BUS- GND GND REF_CLK+ REF_CLK- GND
J1 Row A Row B Row C Row D Row E Row F Row G Row H Row I1 PB1_RD3- PA1_RD3- GND GND PA1_TD3+ PA1_TD3- GND GND P1-RES_BUS_SE2 GND GND PA1_RD2+ PA1_RD2- GND GND PA1_TD2+ PA1_TD2- GND3 P1A_RD1+ PA1_RD1- GND GND PA1_TD1+ PA1_TD1- GND GND P1-VBAT4 GND GND PA1_RD0+ PA1_RD0- GND GND PA1_TD0+ PA1_TD0- GND5 PB1_RD3+ PB1_RD3- GND GND PB1_TD3+ PB1_TD3- GND GND SYS_CON1*6 GND GND PB1_RD2+ PB1_RD2- GND GND PB1_TD2+ PB1_TD2- GND7 PB1_RD1+ PB1_RD1- GND GND PB1_TD1+ PB1_TD1- GND GND8 GND GND PB1_RD0+ PB1_RD0- GND GND PB1_TD0+ PB1_TD0- GND9 PC1_RD3+ PC1_RD3- GND GND PC1_TD3+ PC1_TD3- GND GND
10 GND GND PC1_RD2+ PC1_RD2- GND GND PC1_TD2+ PC1_TD2- GND11 PC1_RD1+ PC1_RD1- GND GND PC1_TD1+ PC1_TD1- GND GND12 GND GND PC1_RD0+ PC1_RD0- GND GND PC1_TD0+ PC1_TD0- GND13 PC1_RD3+ PD1_RD3- GND GND PD1_TD3+ PD1_TD3- GND GND14 GND GND PD1_RD2+ PD1_RD2- GND GND PD1_TD2+ PD1_TD2- GND15 PC1_RD1+ PD1_RD1- GND GND PD1_TD1+ PD1_TD1- GND GND16 GND GND PD1_RD0+ PD1_RD0- GND GND PD1_TD0+ PD1_TD0- GND
1 877 HYBRICON WWW.HYBRICON.COM2
2
CONNECTOR PINOUT/POWER TABLES
Cable Connectors
1 877 HYBRICON 3 WWW.HYBRICON.COM
Connector JX4: Molex 43045-0420JX4 Pin Signal Jumper Configuration
1 P1-VBAT Jumper Pin 1 - Pin 3 for VBAT tied to +3.3 VAUX local to backplane
2 P1-VBAT Apply external VBAT power source between Pin 2(+) & Pin 4(-) for separate VBAT
3 +3.3 VAUX4 GND
Single Ended System Management ConnectionsHeader: 0.025” Sq. Pins, 0.10” SpacingW12 Pin Signal
1 GND
2 SM33 SM24 SM15 SM0
Connection Power Rail Size CurrentST 1 VS1 #10 80A
ST 2 VS2 #10 80A
ST 3 GND #10 80A
ST 4 GND #10 80A
ST 5 GND #10 80A
ST 6 VS3 #10 80A
ST 7 VS3 #10 80A
ST 8 VS3 #10 80A
ST 9 GND #10 80A
ST 10 GND #10 80A
ST11 GND #10 80A
FS1 CGND #6
Connector PWR1: 232-223-24Molex 43879-0043Pin Power Rail Current1 +3.3 VAUX 8A
2 +3.3 VAUX 8A
3 +3.3 VAUX 8A
4 +3.3 VAUX 8A
5 +12 VAUX 8A
6 +12 VAUX 8A
7 +12 VAUX 8A
8 +12 VAUX 8A
9 -12 VAUX 8A
10 -12 VAUX 8A
11 -12 VAUX 8A
12 -12 VAUX 8A
13 GND 8A
14 GND 8A
15 GND 8A
16 GND 8A
17 GND 8A
18 GND 8A
19 GND 8A
20 GND 8A
21 GND 8A
22 GND 8A
23 GND 8A
24 GND 8A
Connector JX1: 232-506-06Molex 43045-0619Pin Power Rail/
SignalCurrent
1 NC 2A
2 NC 2A
3 SYSRESET* 2A
4 GND 2A
5 GND 2A
6 GND 2A
Power Connections / Current Ratings
Connector JX2: 232-506-12Molex 43045-1219Sense ConnectorPin Power Rail/
SignalCurrent
1 VS3
2 +3.3 VAUX
3 +12 VAUX
4 -12 VAUX
5 VS1
6 VS2
7 GND
8 GND
9 GND
10 GND
11 GND
12 GND
Connector JX3: 232-506-12Molex 43045-1219 Sense ConnectorPin Power Rail/
SignalCurrent
1 VS3
2 +3.3 VAUX
3 +12 VAUX
4 -12 VAUX
5 VS1
6 VS2
7 GND
8 GND
9 GND
10 GND
11 GND
12 GND
JUMPERS/OPTIONAL TERMINATIONS
Jumpers
1 877 HYBRICON WWW.HYBRICON.COM4
Jumper: AMP 530153-2Jumper Jumper Function Default
JP6 Slot 1 SYSCON* InstalledJP7 Slot 2 SYSCON* -JP8 Slot 3 SYSCON* -JP9 Slot 4 SYSCON* -
JP10 Slot 5 SYSCON* -JP3 NVMRO -
Optional Terminations & Default Termination Info.
Bus Termination Default
REF_CLK 61.9 Ohms Differential
REF_BUS none
NVRMO 220 Ohms to 3.3 VAUX
RES_BUS_SE none
SYSRESET*
220 Ohm/1.8k Ohm pullup/down to 3.3
VAUXSM (0-3) none
61.961.9
Fabric Connection
Illustrations
1 877 HYBRICON WWW.HYBRICON.COM5
FABRIC CONNECTION/ILLUSTRATIONS
0.212”
≈
1” Pitch
Figure 2 - Daisy Chain
4X Link From 4X Link ToSlot From Port From Slot To Port To
1 A 2 A
1 B 3 A
1 C 4 A
1 D 5 A
2 B 3 B
2 C 4 B
2 D 5 B
3 C 4 C
3 D 5 C
4 D 5 D
Illustrations (Front View)
1 877 HYBRICON WWW.HYBRICON.COM6
SLOT KEY 1 (top) KEY 2 (middle) KEY 3 (bottom)1 315 dregees 270 degrees 270 degrees2 315 dregees 315 degrees 270 degrees3 315 dregees 0 degrees 270 degrees4 315 dregees 45 degrees 270 degrees5 315 dregees 90 degrees 270 degrees6 315 dregees 270 degrees 315 dregees
6.965”
ILLUSTRATIONS
<
<
<
<
10.317”
Key 1
J0
J1
J2
J3
J4
J5
J6
Key 2
Key 3
Illustrations (Rear View)
1 877 HYBRICON WWW.HYBRICON.COM7
ILLUSTRATIONS
VS
1 +12V
VS
2 +12V
GN
D
GN
D
GN
D
GN
D
GN
D
VS
3 +5V
VS
3 +5V
VS
3 +5V
GN
D
JX1
JX3
JX2
JX4
SLOT KEY 1 (top)1 315 dregees2 315 dregees3 315 dregees4 315 dregees5 315 dregees6 315 dregees
SLOT KEY 2 (middle)1 270 degrees2 315 degrees3 0 degrees4 45 degrees5 90 degrees6 270 degrees
SLOT KEY 3 (bottom)1 270 degrees2 270 degrees3 270 degrees4 270 degrees5 270 degrees6 315 dregees