7. Wellflo - ESP Design and Analysis

Embed Size (px)

Citation preview

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    1/24

    Example 7

    FloSystem User Course

    ESP Design and Analysis

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    2/24

    ESP Design and

    Analysis Modes

    Design Mode

    Entering a Setting depth, max. OD, Op. frequency, Wear factors and

    Efficiency.

    A selection of the Pump/Motor is made

    Selection is made from a internal database of five manufacturers dataAnalysis Mode

    The Pump/Motor (ESP) has been selected

    Performance of the ESP can be analysed running sensitivities :

    Pump variables e.g. Operating Frequency

    Reservoir parameters e.g. Water cut

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    3/24

    ESP Design Mode

    Open ESP.WFL - Review Reservoir, Deviation, and Equipment Data

    The completion string contains an ESP at the bottom of the tubing (i.e. 14632 ft)

    Select Data Preparation - ESP Data...

    Revise the Pump Environment box :

    Note the Measured depth is the pump depth

    OD and ID are chosen considering the casing ID

    Operating frequency is a typical value

    Upstream temperature used only in manual mode calculations (leave as

    default)

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    4/24

    ESP Data... :

    Design Mode only

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    5/24

    ESP Data... :

    Design Mode only

    Revise the values of Wear factors/Efficiencybox

    Note the wear factor are set to 1 for the pump and

    motor (i.e. no wear assumed)

    The efficiency of the gas separator is 100% i.e. nofree gas through the pump

    Revise the Calculations options box

    The viscosity and gassiness are switched on

    TheAnalysis equipmentbox can not be edited in

    this mode

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    6/24

    ESP Design... :

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    7/24

    ESP Design Rate :

    Liq. = 450 stb/day Select Analysis - Operating Point...

    Select Calculate, Results and Plot

    Note Operating Pressure = 3547 psia and Liquid rate = 110 stb/day

    (very low for this well)

    SelectAnalysis - Pressure Drop

    select Edit Rates... and set the design rate of 450 stb/day. Select

    calculate, results and plot

    note that the pressure at pump depth is 3226 psia

    Select Analysis - ESP Design...

    Note the Design liquid rateis set at 450 stb/day

    Verify with Choose ESP...that the list is empty

    Revise the Correlations...options

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    8/24

    ESP Design... Box

    Select Calculateand then Choose ESP...

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    9/24

    ESP Design:

    Choose Pump

    Revise the suitable list of Pump - Motor

    Choose Pump T4-500, motor T5 Series from

    manufacturer ESP Inc. and Cable #2

    Select Plot toobtain the ESP performance

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    10/24

    ESP Pump Performance

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    11/24

    ESP Optimisation Pump Performance

    Select Optimise... to optimise theconfiguration in terms of

    Frequency,

    Number of stages or

    Three performance criteria (minimum,

    maximum flowrate, or most efficient operating

    point)Cable size powerlosses will be included

    in the Electrical Powerresults

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    12/24

    ESP Optimisation Pump Performance

    Frequency: design calculations repeated to obtainoptimum number of stages and flowrate

    Number of Stages: the new operating frequency is

    estimated by reiteration (equations not shown)

    Performance: the operating frequency and number

    of stages are computed by iteration such that the

    operating rate (P and T from mid-point of pump

    depth) corresponds to the minimum, maximum orbest efficiency value

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    13/24

    ESP Optimisation Pump Performance

    As exercise optimise using the followingparameters:

    70 Hz

    reduce the number of stages to 103

    change the performance to best efficiency

    Review the impact of these changes on other

    design parameters

    ESP D i

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    14/24

    ESP DesignInstall...

    ESP A l i

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    15/24

    ESP Analysis

    Mode

    Note that the switch Design mode only is

    switched off indicating that the Analysis

    modeis on

    TheAnalysis equipmentbox is now editable

    and displays the pump and motor parameters

    installed

    Select OK if satisfied with pump selected. SelectAnalysis - Operating Point (Edit rates -

    Fill)

    Note that the new Operating Pressure is 3240

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    16/24

    ESP Analysis

    ESP Analysis:

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    17/24

    ESP Analysis:

    Sensitivity Studies

    Once optimum parameters: Setting depth, Tubingsize, FHTP and a Pump/Motor has been selected

    Check sensitivity to

    Changing Reservoir Pressure

    Increasing watercut

    Check Sensitivity to

    Increase no of stages to increase flexibility if requiredOperating frequency

    ESP A l i O

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    18/24

    ESP Analysis: Op.

    Frequency (VFD)

    Return toAnalysis - Operating Pointand selectSensitivities...

    Note that Sensitivity 2 is set to Operating

    frequency with values: 30, 45, 60, 75 and 90 Hz

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    19/24

    ESP VFD Sensitivity

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    20/24

    ESP VFD Sensitivity

    minimum rate

    maximum rate

    best efficiency

    rate

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    21/24

    WaterCut

    Sensitivity Return toAnalysis - Operating pointand select

    Sensitivities...

    Note that sensitivity one is set to water cut with

    values : 0, 25, 50, 75, 99 %

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    22/24

    WaterCut

    sensitivity

    0 % Water cut

    99% Water cut

    ESP & Simulation

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    23/24

    ESP & Simulation

    VFP Tables

    After all sensitivity runs have been done select Analysis - Export VFP

    file... to input VFP tables to a simulator. Following are typical

    requirements:

    Rate FTHP w.c. GOR Frequency

    b/d psia frac MSc/bbl Hz

    100 50 0.0 0.49 30200 100 0.1 45

    300 200 0.25 60

    500 300 0.5 75

    750 500 0.75 90

    1000 750 0.99

    6 x 6 x 6 x 1 x 5 = 1080 runs

    ESP Design:

  • 7/22/2019 7. Wellflo - ESP Design and Analysis

    24/24

    ESP Design:

    Manual Intervention

    Manual Calculations required for :

    Packer Selection

    Protector Design

    Tubing Stresses

    Junction Box, transformers, switchboard