1
700 Series Gas Divider Features Applications Specifications •Accurate gas dilutions using sonic nozzles and high-precision pressure regulators •Fast response time •Remote operation capability •Computer interface via AK protocol •Long-term stability •ISO 17025 and 1065 compliant •NOx converter efficiency test option •19-inch rack mount •Calibration and linearization of gas analyzers •Linearization of exhaust-emission test benches in automotive industry •Creating specific gas concentrations from master tank •Testing NOx converter efficiency Accuracy – 0.5% Flow Rate – 2.5 L/min Carrier Gas – Requires dry, -40°C air or nitrogen Fittings – ¼-inch Swagelok ® Pressure – Inlet 3-bar, outlet up to 1 bar Power consumption – Max. 150 Watts Power requirements – 115 VAC/60 Hz or 230 VAC/50 Hz Dimensions – 5.25” H x 17” W x 20” D Weight Approximately 40 lbs. Precision 64-point gas divider eliminates the requirement for multiple gas cylinders. California Analytical Instruments 1312 West Grove Ave., Orange, CA 92865 Phone: 714-974-5560 • Fax: 714-921-2531 www.gasanalyzers.com

700 Series Gas Divider Sheet Data Sheet...Gas Divider Features Applications Specifi cations • Accurate gas dilutions using sonic nozzles and high-precision pressure regulators •

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 700 Series Gas Divider Sheet Data Sheet...Gas Divider Features Applications Specifi cations • Accurate gas dilutions using sonic nozzles and high-precision pressure regulators •

700 SeriesGas Divider

Features

Applications

Specifi cations

• Accurate gas dilutions using sonic nozzles and high-precision pressure regulators

• Fast response time

• Remote operation capability

• Computer interface via AK protocol

• Long-term stability

• ISO 17025 and 1065 compliant

• NOx converter effi ciency test option • 19-inch rack mount

• Calibration and linearization of gas analyzers

• Linearization of exhaust-emission test benches in automotive industry

• Creating specifi c gas concentrations from master tank

• Testing NOx converter effi ciency

• Accuracy – 0.5%

• Flow Rate – 2.5 L/min

• Carrier Gas – Requires dry, -40°C air or nitrogen

• Fittings – ¼-inch Swagelok®

• Pressure – Inlet 3-bar, outlet up to 1 bar

• Power consumption – Max. 150 Watts

• Power requirements – 115 VAC/60 Hz or 230 VAC/50 Hz

• Dimensions – 5.25” H x 17” W x 20” D

• Weight – Approximately 40 lbs.

Precision 64-point gas divider eliminates the requirement for multiple gas cylinders.

California Analytical Instruments1312 West Grove Ave., Orange, CA 92865

Phone: 714-974-5560 • Fax: 714-921-2531www.gasanalyzers.com