46
7415 x Made in Germany fluid sensors and diagnostic systems bus, identification and control systems position sensors and object recognition 7415 x Made in Germany 2010

7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

7415 xMade in Germany

fluid sensors and diagnostic

systems

bus, identification

and control systems

position sensors

and objectrecognition

7415 xMade in Germany

2010

Page 2: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Complete product range: sockets, plugs, jumper cables, splitter boxes.

Various cable materials for different applications.

High-quality materials for maximum reliability.

“ecolink” series with innovative quality features.

Integrated LEDs for easy diagnosis.

Connection technology

With a wide variety of different sensor designs ifm electronic offers a wide range ofhigh quality connectors. The choice of types covers common M8, M12, M18 typesthrough to valve plugs. The “ecolink” connectors (order no. EVxxxx) offer additionalquality features.

ecolink - a new dimension in connection technology

Due to the special installation of a mechanical end stop the O-ring is always correct-ly compressed and so permanently maintains its sealing function. The connectorremains securely positioned on the unit even in case of extreme vibration andimpacts. Novel design and a transparent black housing ensure that even in brightlighting conditions the LEDs are more clearly visible than with the clear transparentversions.

For industrial applications:

High-quality materials suited to the requirements in industrial environments. Largelyresistant to oils and greases.

For hygienic and wet areas:

PVC housing and cable, gold-plated contacts and high-grade stainless steel nuts arethe optimum choice for long life.

For oils and coolants:

With PUR housings, cable with full PUR sheaths, Viton seals and gold contacts, theseproducts set new standards for the harsh operating conditions of the machine toolindustry.

For hazardous areas

Connection technology for ATEX categories 2D, 3D and 3G. With the EC typeexamination certificate for components from DEKRA EXAM the connection technol-ogy meets the strictest requirements.

For welding applications

Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated couplingnuts prevent weld spatter sticking. The cables are also suited for drag chains and tor-sional movements.

For sensors in robust applications:

The saw tooth contoured vibration protection secures against strong shocks andvibrations. The high protection rating, wide temperature range and high-qualityhousing materials (high-grade stainless steel, TPU) ensure permanent safe connectionin harsh environments.

Black, transparenthousing for optimumLED visibility.

Maximum operationalreliability due to the

new vibration protec-tion with end stop.

Connection technology

2www.ifm.com

Page 3: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Sockets for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M8, 3-pole, 3-wire, angled

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 1 E11489

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 1 E11490

10 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 1 E11491

Socket M8, 3-pole, 3-wire, straight

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 2 E11486

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 2 E11487

10 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 2 E11488

Socket M8, 3-pole, 3-wire, angled, LED, PNP

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

3 E11492

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

3 E11493

10 m blackPUR cable 3 x 0.34 mm2, Ø 5 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

3 E11494

Socket M8, 4-pole, 4-wire, angled

2 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 4 E11199

5 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 4 E11200

10 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 4 E11201

Socket M8, 4-pole, 4-wire, straight

2 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 5 E11196

5 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 5 E11197

10 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 5 E11198

socket M12, 2-pole for AS-i isolation displacement connector

– NBR – -25...70 IP67 – 6 E70271

Socket M12, 2-pole, 4-wire, angled

2 m blackPUR cable 2 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 7 EVC164

5 m blackPUR cable 2 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 7 EVC165

Connection technology

3www.ifm.com

Page 4: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 2-pole, 4-wire, angled

10 m blackPUR cable 2 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 7 EVC166

Socket M12, 2-pole, 2-wire, straight

2 m blackPUR cable 2 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC161

5 m blackPUR cable 2 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC162

10 m blackPUR cable 2 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC163

socket M12, 2-pole + PE, 3-wire

2 m orangePVC cable

3 x AWG 22 (3 x0.34 mm2), Ø 5 mm

TPU /brass

250 AC300 DC

-25...90 IP67 – 9 E10865

5 m orangePVC cable

3 x AWG 22 (3 x0.34 mm2), Ø 5 mm

TPU /brass

250 AC300 DC

-25...90 IP67 – 9 E10866

2 m orangePVC cable

3 x AWG 22 (3 x0.34 mm2), Ø 5 mm

TPU /brass

250 AC300 DC

-25...90 IP67 – 10 E10867

5 m orangePVC cable

3 x AWG 22 (3 x0.34 mm2), Ø 5 mm

TPU /brass

250 AC300 DC

-25...90 IP67 – 10 E10868

Socket M12, 4-pole, angled

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 11 E11509

wirable ...0.75 mm2 (Ø 6...8 mm)PBT (Pocan) /stainless steel

125 AC150 DC

-40...85 IP68 – 12 E11252

Socket M12, 4-pole, straight

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 13 E11508

wirable – PA 6.6 250 AC/DC -25...60 IP67 – 14 E11145

Socket M12, 4-pole, angled, LED, PNP

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

10...30 DC -25...100 IP68green /yellow

15 E11510

Socket M12, 4-pole, straight, LED, PNP

wirable ...0.75 mm2 (Ø 4...6 mm) PA 10...30 DC -40...85 IP67green /yellow

13 E10136

Socket M12, 4/5-pole, 4-wire, angled

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVC004

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVC005

Connection technology

4www.ifm.com

Page 5: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4/5-pole, 4-wire, angled

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVC006

Socket M12, 4/5-pole, 4-wire, straight

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVC001

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVC002

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVC003

Socket M12, 4/5-pole, 4-wire, angled, LED, PNP

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVC007

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVC008

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVC009

Socket M12, 5-pole, angled

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

125 AC/DC -25...100 IP68 – 19 E11512

Socket M12, 5-pole, straight

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

125 AC/DC -25...100 IP68 – 20 E11511

Socket M12, 5-pole, 5-wire, straight

2 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 21 E11596

5 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 21 E11597

Terminating resistor socket M12, 5-pole, straight

M12 connector –TPU /brass

– -40...90 IP67 / IP69K – 22 E11589

Socket M12, 5-pole, 5-wire, angled

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 23 EVC073

5 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 23 EVC074

10 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 23 EVC075

Connection technology

5www.ifm.com

Page 6: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 5-pole, 5-wire, straight

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 24 EVC070

5 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 24 EVC071

10 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 24 EVC072

Socket M12, 8-pole, 6-wire, straight

5 m blackPUR / PVC cable 6 x 0.34 mm2, Ø 6 mm

TPU /brass

30 AC36 DC

-25...90 IP67 – 25 E10976

10 m blackPUR / PVC cable 6 x 0.34 mm2, Ø 6 mm

TPU /brass

30 AC36 DC

-25...90 IP67 – 25 E10977

socket M12, 8-pole, 7-wire + screen

2 m orangePUR cable 7 x 0.25 mm2 + screen

TPU /brass

30 AC36 DC

-25...90 IP67 – 25 E20738

5 m PUR cable 7 x 0.25 mm2 + screen

TPU /brass

30 AC36 DC

-25...90 IP67 – 25 E20838

socket M12, 8-pole, 8-wire, for temperature sensors TR 8...

2 m blackPUR cable 8 x 0.25 mm2, Ø 6.2 mm

PUR /brass

30 AC36 DC

-25...80 IP68 – 26 E11231

5 m blackPUR cable 8 x 0.25 mm2, Ø 6.2 mm

PUR /brass

30 AC36 DC

-25...80 IP68 – 26 E11232

2 m blackPUR cable 8 x 0.25 mm2, Ø 6.2 mm

PUR /brass

30 AC36 DC

-25...80 IP68 – 27 E11950

5 m blackPUR cable 8 x 0.25 mm2, Ø 6.2 mm

PUR /brass

30 AC36 DC

-25...80 IP68 – 27 E11807

10 m blackPUR cable 8 x 0.25 mm2, Ø 6.2 mm

PUR /brass

30 AC36 DC

-25...80 IP68 – 27 E11311

Socket M12, 8/7-pole, 8-wire, angled

5 m blackPUR cable 8 x 0.25 mm2 TPU /

brass30 AC36 DC

-25...90 IP68 – 26 E12168

10 m blackPUR cable 8 x 0.25 mm2 TPU /

brass30 AC36 DC

-25...90 IP68 – 26 E12169

Socket M12, 8/7-pole, 8-wire, straight

5 m blackPUR cable 8 x 0.25 mm2 TPU /

brass30 AC36 DC

-25...90 IP68 – 27 E12166

10 m blackPUR cable 8 x 0.25 mm2 TPU /

brass30 AC36 DC

-25...90 IP68 – 27 E12167

socket M16, 14-pole, 10-wire

5 m blackPUR cable

8 x 0.34 mm2 + 2 x0.75 mm2, Ø 9.1 mm

PUR /brass

30 DC -25...90 IP68 – 28 E11226

10 m blackPUR cable

8 x 0.34 mm2 + 2 x0.75 mm2, Ø 9.1 mm

PUR /brass

30 DC -25...90 IP68 – 28 E11227

Socket M16, 14-pole, 12-wire, angled

2 m blackPUR cable

10 x 0.25 mm2 + 2 x0.34 mm2, Ø 7.5 mm

PUR /brass

30 DC -25...90 IP67 – 29 E11645

5 m blackPUR cable

10 x 0.25 mm2 + 2 x0.34 mm2, Ø 7.5 mm

PUR /brass

30 DC -25...90 IP67 – 29 E11697

Connection technology

6www.ifm.com

Page 7: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M18, 4-pole, angled

wirable ...0.75 mm2 (Ø 6...8 mm) PA20...250AC/DC

-40...85 IP65 – 30 E10013

Socket M18, 4-pole, straight

wirable ...0.75 mm2 (Ø 6...8 mm)PA /

ULTRAMID20...250AC/DC

-40...85 IP65 – 31 E10137

Socket M18, 12-pole, straight

soldering ...0.25 mm2 (Ø 6...8 mm) brass 4.5...30 DC -40...85 IP67 – 32 E60174

Socket M18, 12-pole, angled

soldering ...0.25 mm2 (Ø 6...8 mm) brass 4.5...30 DC -40...85 IP67 – 33 E60175

socket M23, 12-pole, numbering anticlockwise

soldering ...1 mm2 (Ø 10...14 mm) brass 10...30 DC -25...90 IP65 – 34 E10447

soldering ...1 mm2 (Ø 10...14 mm) brass 10...30 DC -25...90 IP65 – 35 E10448

soldering ...1 mm2, Ø 8 mm brass 4.5...30 DC -40...125 IP67 – 36 E60124

socket M23, 12-pole, numbering clockwise, for encoders

soldering ...1 mm2, Ø 8 mm brass 4.5...30 DC -40...125 IP67 – 37 E60122

soldering ...1 mm2 (Ø 4.5...6 mm) brass 4.5...30 DC -40...125 IP67 – 38 E60136

5 m PUR cable

8 x 0.14 mm2 + 4 x0.5 mm2, Ø 8 mm

brass 4.5...30 DC -25...80 IP67 – 39 E60144

10 m PUR cable

8 x 0.14 mm2 + 4 x0.5 mm2, Ø 8 mm

brass 4.5...30 DC -25...80 IP67 – 39 E60147

plug M23, 12-pole, numbering anticlockwise

soldering ...1 mm2, Ø 8 mm brass 4.5...30 DC -40...125 IP67 – 40 E60141

socket M23, 17-pole, numbering clockwise

Soldering/crimpingconnection ...0.5 mm2, Ø 8 mm brass 4.5...30 DC -40...125 IP67 – 41 E60157

Connection technology

7www.ifm.com

Page 8: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

socket M23, 21-pole, numbering clockwise

Soldering/crimpingconnection ...0.5 mm2, Ø 8 mm brass 4.5...30 DC -40...125 IP67 – 42 E60146

Socket M23, 12-pole, angled

5 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

PUR /brass

250 AC/DC -25...80 IP67 – 43 E11739

10 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

PUR /brass

250 AC/DC -25...80 IP67 – 43 E11740

15 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

PUR /brass

250 AC/DC -25...80 IP67 – 43 E11741

Socket M23, 12-pole, straight

5 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

PUR /brass

250 AC/DC -25...80 IP67 – 44 E11736

10 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

PUR /brass

250 AC/DC -25...80 IP67 – 44 E11737

15 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

PUR /brass

250 AC/DC -25...80 IP67 – 44 E11738

Socket M23, 19-pole, angled

5 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

PUR /brass

160 AC/DC -25...80 IP67 – 45 E11745

10 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

PUR /brass

160 AC/DC -25...80 IP67 – 45 E11746

15 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

PUR /brass

160 AC/DC -25...80 IP67 – 45 E11747

Socket M23, 19-pole, straight

5 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

PUR /brass

160 AC/DC -25...80 IP67 – 46 E11742

10 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

PUR /brass

160 AC/DC -25...80 IP67 – 46 E11743

15 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

PUR /brass

160 AC/DC -25...80 IP67 – 46 E11744

socket 1/2“, 2-pole + PE, 3-wire

2 m yellowPVC cable

3 x AWG22, Ø 5.2 mmTPU /brass

250 AC300 DC

-25...90 IP67 – 47 E10190

5 m yellowPVC cable 3 x 0.34 mm2, Ø 5.2 mm

TPU /brass

250 AC300 DC

-25...90 IP67 – 47 E10200

2 m yellowPVC cable

3 x AWG22, Ø 5.2 mmTPU /brass

250 AC300 DC

-25...90 IP67 – 48 E10189

5 m yellowPVC cable

3 x AWG22, Ø 5.2 mmTPU /brass

250 AC300 DC

-25...90 IP67 – 48 E10191

10 m orangePVC cable

3 x AWG22, Ø 5.2 mmTPU /brass

250 AC300 DC

-25...90 IP67 – 47 E10261

Connection technology

8www.ifm.com

Page 9: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

socket 1/2“, 2-pole + PE, 3-wire

10 m yellowPVC cable

3 x AWG22, Ø 5.2 mmTPU /brass

250 AC300 DC

-25...90 IP67 – 48 E11661

socket 1/2“, 5-pole, 4-wire

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

TPU /brass

300 AC -25...90 IP67 – 54 E11248

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

TPU /brass

300 AC -25...90 IP67 – 54 E11249

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

TPU /brass

300 AC -25...90 IP67 – 55 E11250

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

TPU /brass

300 AC -25...90 IP67 – 55 E11251

socket 7/8“, 2-pole + PE, 3-wire

2 m orangePVC cable 3 x 0.75 mm2, Ø 5.2 mm TPU 250 AC -40...90 IP68 – 51 E20428

socket 7/8“, 3-pole, 3-wire

2 m orangePVC cable 3 x 0.75 mm2, Ø 5.2 mm TPU 10...30 DC -40...90 IP68 – 51 E20430

socket DIN A (DIN 43650)

wirable ...1.5 mm2 (Ø 6...8 mm) PA... 250 AC...300 DC

-40...125 IP65 – 52 E10058

socket Rd24, 6-pole + PE

wirable ...2.5 mm2 (Ø 10...12 mm) PBT250 AC300 DC

-40...100 IP67 – 50 E70142

wirable ...2.5 mm2 (Ø 6...8 mm)PBT /PA

250 AC300 DC

-40...100 IP67 – 53 E11043

socket bayonet, for pressure sensors type PP....

2 m blackPUR cable 4 x 0.5 mm2 Hytrel G-4774 9.6...30 DC -40...85 IP67 / IP69K – 49 E11273

Cable plugs for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Plug M8, 3-pole, straight

wirable –PA /brass

60 AC75 DC

-25...90 IP68 – – E11550

Connection technology

9www.ifm.com

Page 10: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M8, 3-pole, straight

wirable –PA /brass

60 AC75 DC

-25...90 IP68 – – E11552

Plug M8, 4-pole, straight

wirable –PA /brass

60 AC75 DC

-25...90 IP68 – – E11551

Socket M8, 4-pole, straight

wirable –PA /brass

60 AC75 DC

-25...90 IP68 – – E11553

Plug M12, 4-pole, 4-wire, angled

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 56 EVC079

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 56 EVC080

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 56 EVC081

Plug M12, 4-pole, 4-wire, straight

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 57 EVC076

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 57 EVC077

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 57 EVC078

Plug M12, 4-pole, angled

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 58 E11505

Plug M12, 4-pole, straight

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 59 E11504

Plug M12, 5-pole, 5-wire, angled

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 60 EVC095

Plug M12, 5-pole, 5-wire, straight

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 61 EVC094

Connection technology

10www.ifm.com

Page 11: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Plug M12, 5-pole, angled

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

125 AC/DC -25...100 IP68 – 62 E11507

Plug M12, 5-pole, straight

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

125 AC/DC -25...100 IP68 – 63 E11506

plug M23, 12-pole, numbering clockwise

soldering ...1 mm2, Ø 6 mm brass 4.5...30 DC -40...125 IP67 – 64 E60123

soldering ...1 mm2, Ø 4.5 mm brass 4.5...30 DC -40...125 IP67 – 64 E60128

Plug M12, 5-pole, 5-wire, straight

2 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 65 E11598

5 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 65 E11599

Terminating resistor plug M12, 5-pole, straight

M12 connector –TPU /brass

– -40...90 IP67 / IP69K – 66 E11590

Connection cables for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M8, 3-pole, 3-wire, straight / angled

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 67 E11324

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 67 E11325

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 67 E11326

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 67 E11327

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 67 E11328

Jumper M8, 3-pole, 3-wire, straight / straight

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 68 E11319

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 68 E11320

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 68 E11321

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 68 E11322

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 68 E11323

Connection technology

11www.ifm.com

Page 12: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M8, 3-pole, 3-wire, straight / angled, LED

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

69 E11329

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

69 E11330

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

69 E11331

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

69 E11332

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

69 E11333

jumper M8 plug, 3-pole / M8 socket, 4-pole

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 70 E11337

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 70 E11338

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 70 E11204

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 70 E11205

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 70 E11339

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 71 E11334

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 71 E11335

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 71 E11202

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 71 E11203

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 71 E11336

Jumper M8, 4-pole, 3-wire, straight / straight

0.2 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...80 IP65 / IP67 – 72 E12155

jumper M8 plug, 4-pole / M8 socket, 3-pole

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 73 E11267

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 73 E11268

jumper M8 plug, 4-pole / M8 socket, 4-pole

1 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 74 E11208

2 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 74 E11209

1 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 72 E11206

2 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...80 IP68 – 72 E11207

Connection technology

12www.ifm.com

Page 13: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12 - M8, 3-pole, 3-wire, straight / angled

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 75 E11381

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 75 E11382

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 75 E11383

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 75 E11384

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 75 E11385

Jumper M12 - M8, 3-pole, 3-wire, straight / straight

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 76 E11376

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 76 E11377

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 76 E11378

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 76 E11379

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 76 E11380

Jumper M12 - M8, 3-pole, 3-wire, straight / angled, LED

0.3 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

77 E11386

0.6 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

77 E11387

1 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

77 E11388

2 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

77 E11389

5 m blackPUR cable 3 x 0.25 mm2, Ø 4.1 mm

PUR /brass

10...30 DC -25...85 IP68green /yellow

77 E11390

jumper M12 plug, 4-pole / M8 socket, 4-pole

0.3 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 78 E11446

0.6 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 78 E11447

1 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 78 E11212

2 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 78 E11213

5 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 78 E11450

0.3 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 79 E11441

0.6 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 79 E11442

Connection technology

13www.ifm.com

Page 14: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

jumper M12 plug, 4-pole / M8 socket, 4-pole

1 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 79 E11210

2 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 79 E11211

5 m blackPUR cable 4 x 0.25 mm2, Ø 4.4 mm

PUR /brass

60 AC75 DC

-25...85 IP68 – 79 E11445

Jumper M12, 3-pole, 3-wire, straight / angled

0.3 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 80 EVC045

0.6 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 80 EVC046

1 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 80 EVC047

2 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 80 EVC048

5 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 80 EVC049

Jumper M12, 3-pole, 3-wire, straight / straight

0.3 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 81 EVC040

0.6 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 81 EVC041

1 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 81 EVC042

2 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 81 EVC043

5 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 81 EVC044

Jumper M12, 3-pole, 3-wire, straight / angled, LED

0.3 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

82 EVC050

0.6 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

82 EVC051

1 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

82 EVC052

2 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

82 EVC053

5 m blackPUR cable 3 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

82 EVC054

Jumper M12, 4-pole, 4-wire, straight / angled

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 83 EVC015

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 83 EVC016

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 83 EVC017

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 83 EVC018

Connection technology

14www.ifm.com

Page 15: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 4-pole, 4-wire, straight / angled

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 83 EVC019

Jumper M12, 4-pole, 4-wire, angled / straight

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 84 EVC025

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 84 EVC026

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 84 EVC027

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 84 EVC028

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 84 EVC029

Jumper M12, 4-pole, 4-wire, angled / angled

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 85 EVC030

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 85 EVC031

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 85 EVC032

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 85 EVC033

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 85 EVC034

Connection cables for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 4-pole, 4-wire, straight / straight

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

PUR /brass

250 AC300 DC

-25...85 IP68 – 86 E11974

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 87 EVC010

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 87 EVC011

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 87 EVC012

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 87 EVC013

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 87 EVC014

Connection technology

15www.ifm.com

Page 16: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 4-pole, 4-wire, straight / angled, LED

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow88 EVC020

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow88 EVC021

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow88 EVC022

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow88 EVC023

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow88 EVC024

Jumper M12, 4-pole, 4-wire, angled / angled, LED

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow89 EVC035

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow89 EVC036

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow89 EVC037

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow89 EVC038

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow89 EVC039

Jumper M12, 5-pole, 5-wire, straight / angled

0.3 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 90 EVC060

0.6 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 90 EVC061

1 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 90 EVC062

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 90 EVC063

5 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 90 EVC064

Jumper M12, 5-pole, 5-wire, angled / straight

0.3 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 91 EVC065

0.6 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 91 EVC066

1 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 91 EVC067

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 91 EVC068

5 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 91 EVC069

Jumper M12, 5-pole, 5-wire, straight / straight

0.3 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 92 E11591

1 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 92 E11592

Connection technology

16www.ifm.com

Page 17: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 5-pole, 5-wire, straight / straight

2 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 92 E11593

5 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 92 E11594

10 m blackPUR cable

2 x 0.25 mm2 + 3 x0.34 mm2, Ø 6.8 mm

TPU /brass

30 AC36 DC

-40...90 IP67 / IP69K – 92 E11595

0.3 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 93 EVC055

0.6 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 93 EVC056

1 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 93 EVC057

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 93 EVC058

5 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 93 EVC059

Jumper M12, 3/4-pole, 3-wire, straight / angled, LED

0.3 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 94 E11416

0.6 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 94 E11417

1 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 94 E11418

2 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 94 E11419

5 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 94 E11420

0.3 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP65 yellow 95 E11426

Jumper M12, 5/4-pole, 3-wire, straight / angled

1 m PUR cable 2 x 0.75 mm2 TPU /

brass24 AC/DC -40...90 IP67 / IP69K – 96 E11187

0.75 m PUR cable 2 x 0.75 mm2 TPU /

brass24 AC/DC -40...90 IP67 / IP69K – 96 E11277

2 m PUR cable 2 x 0.75 mm2 TPU /

brass24 AC/DC -40...90 IP67 / IP69K – 96 E11622

3 m PUR cable 2 x 0.75 mm2 TPU /

brass24 AC/DC -40...90 IP67 / IP69K – 96 E11949

Y-jumper M12 plug / 2 x valve plug type A (to DIN 43650)

1 m blackPUR cable 3 x 0.5 mm2, Ø 4.8 mm

TPU /brass

10...30 DC -25...90 IP67 2 x yellow 97 E70203

Jumper M12, 3-pole, 3-wire, straight / angled, LED

0.3 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 98 E11421

0.6 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 98 E11422

Connection technology

17www.ifm.com

Page 18: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 3-pole, 3-wire, straight / angled, LED

1 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 98 E11423

2 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 98 E11424

5 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 98 E11425

0.3 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 99 E11431

0.6 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 99 E11432

1 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 99 E11433

2 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 99 E11434

5 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 99 E11435

Jumper M12, 3/4-pole, 3-wire, straight / angled, LED

0.6 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP65 yellow 95 E11427

1 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP65 yellow 95 E11428

2 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP65 yellow 95 E11429

5 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP65 yellow 95 E11430

0.3 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 100 E11436

0.6 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 100 E11437

1 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 100 E11438

2 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 100 E11439

5 m blackPUR cable 3 x 0.5 mm2, Ø 5 mm

PUR /brass

24 AC/DC -25...80 IP67 yellow 100 E11440

Jumper M12, 4/8-pole, 4-wire, straight / straight

2 m greenPUR cable

2 x 2 x 0.38 mm2,Ø 6.2 mm

PUR / PC /brass

– -25...70 IP67 / IP42 – 101 E12090

jumper M12 plug, 4-pole / socket bayonet

2 m blackPUR cable 4 x 0.5 mm2, Ø 6 mm

PA / st. steel316Ti / 1.4571

9.6...30 DC -40...85 IP67 – 102 E11274

Connection technology

18www.ifm.com

Page 19: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Splitter boxes for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

splitter box M8, 3-pole

5 m blackPUR cable

8 x 0.34 mm2 + 2 x0.75 mm2, Ø 9.1 mm

PBT-GF 20 10...30 DC -25...90 IP68green /

8 x yellow103 E11214

10 m blackPUR cable

8 x 0.34 mm2 + 2 x0.75 mm2, Ø 9.1 mm

PBT-GF 20 10...30 DC -25...90 IP68green /

8 x yellow103 E11215

M12 connector – PBT-GF 20 10...30 DC -25...90 IP68green /

4 x yellow104 E11216

splitter box M8, 4-pole

5 m blackPUR cable

16 x 0.34 mm2 + 2 x0.75 mm2, Ø 9.1 mm

PBT-GF 20 10...30 DC -25...90 IP68green /

16 x yellow105 E11217

10 m blackPUR cable

16 x 0.34 mm2 + 2 x0.75 mm2, Ø 9.1 mm

PBT-GF 20 10...30 DC -25...90 IP68green /

16 x yellow105 E11218

M16 connector – PBT-GF 20 10...30 DC -25...90 IP68green /

8 x yellow106 E11219

M12 splitter box for 1 signal

5 m blackPUR cable 4 x 0.25 mm2, Ø 5 mm

TPU /brass

10...55 DC -25...90 IP67 – 107 E10437

5 m blackPUR cable

4 x 0.34 mm2 + 3 x0.75 mm2, Ø 8.4 mm

TPU60 AC75 DC

-15...80 IP67 – 108 E11717

10 m blackPUR cable

4 x 0.34 mm2 + 3 x0.75 mm2, Ø 8.4 mm

TPU60 AC75 DC

-15...80 IP67 – 108 E11718

5 m blackPUR cable

4 x 0.34 mm2 + 3 x0.75 mm2, Ø 8.4 mm

TPU 10...30 DC -15...80 IP67green /

4 x yellow108 E10278

10 m blackPUR cable

4 x 0.34 mm2 + 3 x0.75 mm2, Ø 8.4 mm

TPU 10...30 DC -15...80 IP67green /

4 x yellow108 E10279

5 m blackPUR cable

6 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU60 AC75 DC

-15...80 IP67 – 109 E11720

10 m blackPUR cable

6 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU60 AC75 DC

-15...80 IP67 – 109 E11721

5 m blackPUR cable

6 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU 10...30 DC -15...80 IP67green /

6 x yellow110 E10280

10 m blackPUR cable

6 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU 10...30 DC -15...80 IP67green /

6 x yellow110 E10281

5 m blackPUR cable

8 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU60 AC75 DC

-15...80 IP67 – 111 E11723

10 m blackPUR cable

8 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU60 AC75 DC

-15...80 IP67 – 111 E11724

5 m blackPUR cable

8 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU 10...30 DC -15...80 IP67green /

8 x yellow112 E10282

10 m blackPUR cable

8 x 0.34 mm2 + 3 x0.75 mm2, Ø 9 mm

TPU 10...30 DC -15...80 IP67green /

8 x yellow112 E10283

M23 connector – TPU60 AC75 DC

-15...80 IP67 – 113 E11719

M23 connector – TPU 10...30 DC -15...80 IP67green /

4 x yellow114 E11735

Connection technology

19www.ifm.com

Page 20: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

M12 splitter box for 1 signal

M23 connector – TPU 10...30 DC -15...80 IP67green /

6 x yellow115 E10445

M23 connector – TPU60 AC75 DC

-15...80 IP67 – 116 E11725

M23 connector – TPU 10...30 DC -15...80 IP67green /

8 x yellow117 E10446

M12 splitter box for 2 signals

5 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

TPU60 AC75 DC

-15...80 IP67 – 118 E11726

10 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

TPU60 AC75 DC

-15...80 IP67 – 118 E11727

5 m blackPUR cable

8 x 0.5 mm2 + 3 x1.0 mm2, Ø 9.3 mm

TPU 10...30 DC -15...80 IP67green /

8 x yellow119 E11017

10 m blackPUR cable 8 x 0.5 mm2 + 3 x 1.0 mm2 TPU 10...30 DC -15...80 IP67

green /8 x yellow

119 E11018

5 m blackPUR cable

12 x 0.5 mm2 + 3 x1.0 mm2, Ø 10.4 mm

TPU60 AC75 DC

-15...80 IP67 – 120 E11729

10 m blackPUR cable

12 x 0.5 mm2 + 3 x1.0 mm2, Ø 10.4 mm

TPU60 AC75 DC

-15...80 IP67 – 120 E11730

5 m blackPUR cable

12 x 0.5 mm2 + 3 x1.0 mm2, Ø 10.4 mm

TPU 10...30 DC -15...80 IP67green /

12 x yellow121 E11019

10 m PUR cable

12 x 0.5 mm2 + 3 x1.0 mm2 TPU 10...30 DC -15...80 IP67

green /12 x yellow

121 E11020

5 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

TPU60 AC75 DC

-15...80 IP67 – 122 E11732

10 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

TPU60 AC75 DC

-15...80 IP67 – 122 E11733

5 m blackPUR cable

16 x 0.5 mm2 + 3 x1.0 mm2, Ø 11.6 mm

TPU 10...30 DC -15...80 IP67green /

16 x yellow123 E11021

10 m PUR cable

16 x 0.5 mm2 + 3 x1.0 mm2 TPU 10...30 DC -15...80 IP67

green /16 x yellow

123 E11022

M23 connector – TPU60 AC75 DC

-15...80 IP67 – 124 E11728

M23 connector – TPU 10...30 DC -15...80 IP67green /

8 x yellow125 E10945

M23 connector – TPU60 AC75 DC

-15...80 IP67 – 126 E11731

M23 connector – TPU 10...30 DC -15...80 IP67green /

12 x yellow127 E10946

M23 connector – TPU60 AC75 DC

-15...80 IP67 – 128 E11734

Connection technology

20www.ifm.com

Page 21: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

M12 splitter box for 2 signals

M23 connector – TPU 10...30 DC -15...80 IP67green /

16 x yellow129 E10659

Connectors for oils and coolants

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4/5-pole, 4-wire, angled

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVC004

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVC005

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVC006

Socket M12, 4/5-pole, 4-wire, straight

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVC001

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVC002

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVC003

Socket M12, 4/5-pole, 4-wire, angled, LED, PNP

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVC007

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVC008

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVC009

Connectors for electromagnetric fields

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, 4-wire, angled

2 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVW004

5 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVW005

10 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 16 EVW006

Socket M12, 4-pole, 4-wire, straight

2 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVW001

5 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVW002

Connection technology

21www.ifm.com

Page 22: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, 4-wire, straight

10 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 17 EVW003

Socket M12, 4-pole, 4-wire, angled, LED, PNP

2 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVW007

5 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVW008

10 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow18 EVW009

Socket M12, 5-pole, 5-wire, angled

2 m greyPUR cable 5 x 0.34 mm2, Ø 5.1 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 23 EVW013

5 m greyPUR cable 5 x 0.34 mm2, Ø 5.1 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 23 EVW014

10 m greyPUR cable 5 x 0.34 mm2, Ø 5.1 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 23 EVW015

Socket M12, 5-pole, 5-wire, straight

2 m greyPUR cable 5 x 0.34 mm2, Ø 5.1 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 24 EVW010

5 m greyPUR cable 5 x 0.34 mm2, Ø 5.1 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 24 EVW011

10 m greyPUR cable 5 x 0.34 mm2, Ø 5.1 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 24 EVW012

Connectors for hygienic and wet areas

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M8, 3-pole, 3-wire, angled

5 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 130 E11498

10 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 130 E11499

25 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 130 E11500

Socket M8, 3-pole, 3-wire, straight

5 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 131 E11495

10 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 131 E11496

25 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 131 E11497

Connection technology

22www.ifm.com

Page 23: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M8, 3-pole, 3-wire, angled, LED, PNP

5 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

10...30 DC -25...85 IP68green /yellow

132 E11501

10 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

10...30 DC -25...85 IP68green /yellow

132 E11502

25 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

10...30 DC -25...85 IP68green /yellow

132 E11503

Socket M8, 4-pole, 4-wire, angled

5 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 133 E11220

10 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 133 E11221

25 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 133 E11222

Socket M8, 4-pole, 4-wire, straight

5 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 134 E11223

10 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 134 E11224

25 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 134 E11225

Jumper M12, 3-pole, 3-wire, straight / angled

0.3 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 135 EVT028

0.6 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 135 EVT029

1 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 135 EVT030

2 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 135 EVT031

5 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 135 EVT032

10 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 135 EVT033

Jumper M12, 3-pole, 3-wire, straight / straight

0.3 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 136 EVT022

0.6 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 136 EVT023

1 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 136 EVT024

2 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 136 EVT025

5 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 136 EVT026

10 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 136 EVT027

Connection technology

23www.ifm.com

Page 24: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 3-pole, 3-wire, straight / angled, LED

0.3 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /yellow

137 EVT034

0.6 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /yellow

137 EVT035

1 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /yellow

137 EVT036

2 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /yellow

137 EVT037

5 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /yellow

137 EVT038

10 m orangePVC cable 3 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /yellow

137 EVT039

Socket M12, 4-pole, 4-wire, angled

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 138 EVT067

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 138 EVT004

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 138 EVT005

25 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 138 EVT006

Socket M12, 4-pole, 4-wire, straight

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 139 EVT064

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 139 EVT001

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 139 EVT002

25 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 139 EVT003

Socket M12, 4-pole, angled

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel240 AC/DC -25...90 IP67 / IP69K – 140 E11862

Socket M12, 4-pole, straight

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel240 AC/DC -25...90 IP67 / IP69K – 141 E11861

Socket M12, 4-pole, 4-wire, angled, LED, PNP

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow142 EVT007

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow142 EVT008

25 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow142 EVT009

Socket M12, 4-pole, angled, LED, PNP

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel10...30 DC -25...90 IP67 / IP69K

green /yellow

140 E11863

Connection technology

24www.ifm.com

Page 25: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Plug M12, 4-pole, angled

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel240 AC/DC -25...90 IP67 / IP69K – 143 E11858

Plug M12, 4-pole, straight

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel240 AC/DC -25...90 IP67 / IP69K – 144 E11857

Jumper M12, 4-pole, 4-wire, straight / angled

0.3 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 145 EVT046

0.6 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 145 EVT047

1 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 145 EVT048

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 145 EVT049

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 145 EVT050

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 145 EVT051

Jumper M12, 4-pole, 4-wire, straight / straight

0.3 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 146 EVT040

0.6 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 146 EVT041

1 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 146 EVT042

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 146 EVT043

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 146 EVT044

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 146 EVT045

Jumper M12, 4-pole, 4-wire, straight / angled, LED

0.3 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow147 EVT052

0.6 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow147 EVT053

1 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow147 EVT054

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow147 EVT055

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow147 EVT056

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow147 EVT057

Plug M12, 4-pole, 4-wire, straight

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 148 EVT071

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 148 EVT072

Connection technology

25www.ifm.com

Page 26: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Plug M12, 4-pole, 4-wire, straight

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 148 EVT073

Socket M12, 5-pole, 5-wire, angled

5 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 149 EVT013

10 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 149 EVT014

25 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 149 EVT015

Socket M12, 5-pole, 5-wire, straight

5 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 150 EVT010

10 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 150 EVT011

25 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 150 EVT012

Plug M12, 5-pole, 5-wire, angled

2 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 151 EVT074

Socket M12, 5-pole, angled

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel60 AC/DC -25...90 IP67 / IP69K – 152 E11865

Socket M12, 5-pole, straight

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel60 AC/DC -25...90 IP67 / IP69K – 153 E11864

Plug M12, 5-pole, angled

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel60 AC/DC -25...90 IP67 / IP69K – 154 E11860

Plug M12, 5-pole, straight

wirable ...0.75 mm2 (Ø 4...8 mm)PBT / high-grade

st. steel60 AC/DC -25...90 IP67 / IP69K – 155 E11859

Jumper M12, 5-pole, 5-wire, straight / straight

0.3 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 156 EVT058

0.6 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 156 EVT059

Connection technology

26www.ifm.com

Page 27: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Jumper M12, 5-pole, 5-wire, straight / straight

1 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 156 EVT060

2 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 156 EVT061

5 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 156 EVT062

10 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 156 EVT063

Socket M12, 8/7-pole, 8-wire, straight

2 m blackPUR cable 8 x 0.25 mm2 TPU /

brass30 AC36 DC

-25...90 IP67 – 27 E80021

Socket M12, 8/7-pole, 8-wire, angled

2 m blackPUR cable 8 x 0.25 mm2 TPU /

brass30 AC36 DC

-25...90 IP67 – 26 E80022

splitter box M12

10 m blackPUR / PVC cable

3 x 0.75 mm2 + 16 x0.34 mm2, Ø 11 mm

high-gradestainless steel

10...36 DC -5...70 IP69Kgreen /

16 x yellow157 E11775

Connectors for hazardous areas

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, 4-wire, angled

2 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 16 ENC04A

5 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 16 ENC05A

Socket M12, 4-pole, 4-wire, straight

2 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 17 ENC01A

5 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 17 ENC02A

10 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 17 ENC03A

Socket M12, 4/5-pole, 4-wire, angled

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 158 EVC04A

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 158 EVC05A

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 158 EVC06A

Connection technology

27www.ifm.com

Page 28: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 5-pole, 5-wire, angled

2 m bluePUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 23 ENC10A

5 m bluePUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 23 ENC11A

25 m bluePUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 23 ENC13A

50 m bluePUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 23 ENC14A

Plug M12, 5-pole, 2-wire, angled

0.6 m bluePVC cable 2 x 0.5 mm2, Ø 5.5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 159 E10853

Jumper M12, 4/5-pole, 4-wire, angled / angled

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 160 EVC07A

0.3 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 160 EVC09A

0.6 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 160 EVC10A

1 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 160 EVC11A

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 160 EVC12A

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

60 AC60 DC

-20...60 IP67 – 160 EVC13A

jumper M12 plug / valve plug type A (to DIN 43650)

0.3 m bluePVC cable 2 x 0.5 mm2, Ø 5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 161 E10821

0.6 m bluePVC cable 2 x 0.5 mm2, Ø 5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 161 E10822

jumper M12 plug / valve plug type B (to DIN 43650)

0.3 m bluePVC cable 2 x 0.5 mm2, Ø 5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 162 E10823

jumper M12 plug / valve plug type C (to DIN 43650)

0.6 m bluePUR / PVC cable 2 x 0.5 mm2, Ø 5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 163 E10847

jumper M12 plug / valve plug type B (industrial standard)

0.3 m bluePVC cable 2 x 0.5 mm2, Ø 5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 164 E10825

0.6 m bluePVC cable 2 x 0.5 mm2, Ø 5 mm

TPU / st. steel316L / 1.4404

...15 DC -25...90 IP67 – 164 E10826

Connection technology

28www.ifm.com

Page 29: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Connectors for mobile applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, 4-wire, angled

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 158 EVM004

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 158 EVM005

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 158 EVM006

25 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 158 EVM012

50 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 158 EVM010

Socket M12, 4-pole, 4-wire, straight

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 165 EVM001

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 165 EVM002

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

250 AC300 DC

-40...90IP67 / IP68 /

IP69K– 165 EVM003

Socket M12, 4-pole, 4-wire, angled, LED, PNP

2 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

10...36 DC -40...90IP67 / IP68 /

IP69Kgreen /

2 x yellow166 EVM007

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

10...36 DC -40...90IP67 / IP68 /

IP69Kgreen /

2 x yellow166 EVM008

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU / st. steel316L / 1.4404

10...36 DC -40...90IP67 / IP68 /

IP69Kgreen /

2 x yellow166 EVM009

Jumper M12, 4/8-pole, 4-wire, straight / straight

2 m greenPUR cable

2 x 2 x 0.38 mm2,Ø 6.2 mm

PUR / PC /brass

– -25...70 IP67 / IP42 – 101 E11898

Scale drawings

1

1810

27

M8x1

2

10

M8 x1

31

Connection technology

29www.ifm.com

Page 30: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

3

1026

M8 x1 LED

17

4

10

28

M8 x1

18

5

10

M8 x1

31

6

7

15,5

M12x1 36,5

26,5

14

8

15,5

M12x1 45

14

9

15

M12 x1

39

27

10,5

10

15

M12 x1

10,5

43

11

35

18

20

M12 x1

30

12

19

M12 x1

31

39

18

13

18

M12 x1

46

14

18

M12 x1 1515

52

Connection technology

30www.ifm.com

Page 31: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

15

18

M12 x1

30

35

18

2 LED

16

15,5

M12x1 36,5

26,5

14

17

15,5

M12x1 45

14

18

15,5

M12x1 36,5

26,5

143 LED

19

35

18

20

M12 x1

30

20

20

M12 x1

46

21

15

M12 x1 43

22

M12

x1

43

15

M12 x1

23

15,5

M12x1 36,5

26,5

14

24

15,5

M12x1 45

14

25

43

15

M12 x1

26

15

38

M12 x1

28

10,5

Connection technology

31www.ifm.com

Page 32: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

27

15

M12 x1

43

28

20

M16 x1

47

45

29

4520

M16x1

49

30

25

M18 x1

36

21

43

21

31

25

M18 x1

56

32

18

60

6-8

33

20

37

6-8

53

34

20

58

26

M 23 x1

51

24

35

49

20

26

M 23 x1

36

28

53

37

52

28

38

45

25

20

Connection technology

32www.ifm.com

Page 33: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

39

52

28

L

8

40

53

26

41

52

28

42

52

28

43

51

70

26

M 23 x1

44

26

M 23 x1

85

45

51

70

26

M 23 x1

46

26

M 23 x1

85

47

27

10,5

15

39

G 21

48

42

10,5

15

G 21

49

30

68

50

29

Rd 24

71

Connection technology

33www.ifm.com

Page 34: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

51

6026

G 87

52

2918

42

M322

282

53

29

Rd 24

38,5

20

59

26

54

27

10,5

15

39

"-20UNF21

55

42

10,5

15

"-20UNF21

56

15,5

M12x1

36,5

30,5

14

57

15,5

M12x1 49,5

14

58

42

18

15

20

M12 x1

31

59

5220

M12 x1

60

15,5

M12x1

36,5

30,5

14

61

15,5

M12x1 49,5

14

62

42

18

15

20

M12 x1

31

Connection technology

34www.ifm.com

Page 35: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

63

5220

M12 x1

64

52

28

65

15

M12 x1 47

M12

x1

66

15

M12 x1 46

M12

x1

67

26

M8x1

37 L

M8

x1

17

68

3137 L

M8

x1

M8

x1

69

26

M8x1

37 L

M8

x1

2 LED

17

70

26

M8x1

37 L

M8

x1

17

71

3137 LM

8x1

M8

x1

72

3137 L

M8

x1

M8

x1

73

3137 L

M8

x1

M8

x1

74

26

M8x1

37 L

M8

x1

17

Connection technology

35www.ifm.com

Page 36: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

75

48 L

M12

x1

18

28M8 x1

76

3148 L

M8

x1

M12

x1

77

48 L

M12

x1

18

28M8x1

2 LED

78

48 L

M12

x1

18

28M8 x1

79

3148 L

M8

x1

M12

x1

80

49,5

14

L

15,5

M12x1

M12x1

26,5

14

36,5

15,5

81

49,5

14

15,5

M12x1

45

14

L

15,5

M12x1

82

49,5

14

L

15,5

M12x1

M12x1

26,5

14

36,5

15,5

LED

83

49,5

14

L15

,5

M12x1

M12x1

26,5

14

36,5

15,5

84

15,5

M12x1

45

14

L

M12x1

30,5

14

36,5

15,5

85

L

M12x1

26,5

14

36,5

15,5M12x1

30,5

14

36,5

15,5

86

L 43

M12

x1

M12

x1

47

Connection technology

36www.ifm.com

Page 37: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

87

49,5

14

15,5

M12x1

45

14

L

15,5

M12x1

88

49,5

14

L

15,5

M12x1

M12x1

26,5

14

36,5

15,5

LED

89

L

M12x1

26,5

14

36,5

15,5

LED

M12x1

30,5

14

36,5

15,5

90

49,5

14

L

15,5

M12x1

M12x1

26,5

14

36,5

15,5

91

15,5

M12x1

45

14

L

M12x1

30,5

14

36,5

15,5

92

43

M12

x1

47 L

M12

x1

93

49,5

14

15,5

M12x1

45

14

L

15,5

M12x1

94

L 17,5 29,5

29,5

M12

x1

47

LED

M 3

28,5

95

L 12 20

18

M12

x1

47

LED

M 2,5

21,5

96

M 3

26,5

L 15 26,5

28,4

M12

x1

47

97

L 15 26,5

28,4

46,7

M12

x120

,2

LED

M 3

26,5

17

Connection technology

37www.ifm.com

Page 38: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

98

LED

M 3

28,5

L 17,5 31,5

24

M12

x1

47

99

LED

M 3

28,5

L 17,5 31,5

24

M12

x1

47

100

L 12 20

18

M12

x1

47

LED

M 3

21,5

101

23

M12

x1

47 L

12

102

L52 54

M12

x1

44

103

145 12

9

4,5

4,5

8,51821

M8x1

LED

129

4,5

265

4,5

4,5

11,5

4,5

104

88

27

79

4,5

4,5

8,51821

M8x1

LED

79

4,5

26

M12 x1

4,58,5

5

4,5

16

4,5

105

145 12

9

4,5

4,5

8,51821

11,5

M8x1

LED

129

4,5

26

106

88

27

79

4,5

4,5

8,51821

M16 x 0,75

M8x1

LED

79

4,5

26

Connection technology

38www.ifm.com

Page 39: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

107

15

M12 x1

12

10,5

4212

39108

918

54

73

M12 x1

82

4,5

33

LED

3

1

4

2

109

1854

73

M12x1

100

4,5

33

34

12

56

110

1854

73

M12 x1

100

4,5

33

LED

5

3

1

6

4

2

111

1854

73

M12x1

127

4,5

33

34

12

56

78

112

1854

73

M12 x1

127

4,5

33

LED

7

5

3

1

8

6

4

2

113

M23x1

60

107

39

4,536

34

12

M12x1

3311

118

182528

114

M23x1

60

107

39

4,5

36

34

12

LED M12x1

3311

118

182528

115

1828

60

107

M12 x1

4,5

39

LED

125

M23x1

5

3

1

6

4

2

Connection technology

39www.ifm.com

Page 40: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

116

28

1860

107

M12x1

4,5

39M23x1

152

34

12

56

78

117

1828

60

107

M12 x1

4,5

39

LED

M23x1

152

7

5

3

1

8

6

4

2

118

1118

118

60

107

39

4,5

36

34

12

M12x1

119

1118

118

60

107

39

4,5

36

34

12

LED M12x1

120

60

107

39

4,5

36

12

34

56

M12x1

125

1118

121

125

1118

60

107

39

4,536

12

34

56

M12x1LED

122

152

1118

60

107

39

4,5

36

12

34

56

78

M12x1

123

60

107

39

4,5

36

12

34

56

78

M12x1LED

152

1118

Connection technology

40www.ifm.com

Page 41: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

124

M23x1

60

10739

4,5

36

34

12

M12x133

11

11818

2528

125

M23x1

60

107

39

4,5

36

34

12

LED M12x1

3311

118

182528

126

60

107

M12x1

4,5

39

125

M23x1

34

12

56

18

28

127

18

28

60

107

M12x1

4,5

39

LED

125

M23x1

34

12

56

128

28

1860

107

M12x1

4,5

39

M23x1

152

34

12

56

78

129

28

1860

107

M12x1

4,5

39

LED

M23x1

152

34

12

56

78

130

18

9

28

M8 x1

10

131

10

M8 x1

31

9

132

28

M8 x1

10

18

9

LED

Connection technology

41www.ifm.com

Page 42: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

133

18

9

28

M8 x1

10

134

10

M8 x1

31

9

135

L49

14

15,5

M12 x1

M12x136,5

15,5

26,5

14

136

L

15,5

M12 x1

49

14

45

15,5

M12 x1 14

137

L49

14

15,5

M12 x1

M12x136,5

15,5

26,5

14

LED

138

15,5

M12x1 36,5

26,5

14

139

15,5

45

14

M12 x1

140

35

19

19

21

M12 x1

38

141

52,5

19 19

21

M12 x1

142

15,5

M12x1 36,5

26,5

14LED

143

40

19

19

21

M12 x1

38

144

58

19 19

21

M12 x1

Connection technology

42www.ifm.com

Page 43: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

145

L49

14

15,5

M12 x1

M12x136,5

15,5

26,5

14

146

L

15,5

M12 x1

49

14

45

15,5

M12 x1 14

147

L49

14

15,5

M12 x1

M12x136,5

15,5

26,5

14

LED

148

15,5

49

14

M12 x1

149

15,5

M12x1 36,5

26,5

14

150

15,5

45

14

M12 x1

151

15,5

M12x1 36,5

30,5

14

152

35

19

19

21

M12 x1

38

153

52,5

19 19

21

M12 x1

154

40

19

19

21

M12 x1

38

155

58

19 19

21

M12 x1

156

L

15,5

M12 x1

49

14

45

15,5

M12 x1 14

Connection technology

43www.ifm.com

Page 44: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Scale drawings

15713

7,3

M12 x1

LED

7234

158

15,5

M12x1 36,5

26,5

14

159

M12 x1

39

15

30

10,5

14

160

31

1415,5

26,5

1415,5

36,5 36,5M12x1 M12x1

L

161

M12 x1

L3915

15 26,5

28,4

30

14

10,5

M 3

26,5

162

M12 x1

L3915

15 28,5

22,4

30

14

10,5

M 3

26,5

163

M12 x1

L39

1520,5 15

15

30

14

10,5

M 2,5

25,3

164

L

26,5

M3

28,515

22,4

15

M12x1

39

30

165

15,5

M12x1 45

14

166

3 LED

15,5

M12x1 36,5

26,5

14

Connection technology

44www.ifm.com

Page 45: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

Connection technology

45

Page 46: 7415 x - ifmFor welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited

www.ifm.com