Triple-Band Combiner
Pass bandBand 1 (GSM 900) 880 – 960 MHzBand 2 (GSM 1800) 1710 – 1880 MHzBand 3 (UMTS) 1920 – 2170 MHz
Insertion lossPort 1 Port 4 < 0.2 dB ( 880 – 960 MHz)Port 2 Port 4 < 0.3 dB (1710 – 1880 MHz)Port 3 Port 4 < 0.3 dB (1920 – 2170 MHz)
IsolationPort 1 Port 2 > 50 dB ( 880 – 960 / 1710 – 1880 MHz)Port 1 Port 3 > 50 dB ( 880 – 960 / 1920 – 2170 MHz)Port 2 Port 3 > 50 dB (1710 – 1880 / 1920 – 2170 MHz)
VSWR < 1.2 (880 – 960 / 1710 – 1880 / 1920 – 2170 MHz)
Impedance 50 ΩInput power
Band 1 < 240 WBand 2 < 240 WBand 3 < 60 W
Intermodulation products < –160 dBc (3rd order; with 2 x 20 W)
Temperature range –40 ... +60 °C
Connectors 7-16 female
Application Indoor or outdoor (IP 66)
Special features External DC stop available as an accessory Built-in DC stop between ports 1 and 4, ports 2 and 4DC by-pass between all ports (max. 2500 mA) DC by-pass between ports 3 and 4 (max. 2500 mA)
Built-in lightning protection (3 kA, 10/350 µs pulse)
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)Mast mounting: With additional clamp set
Weight 4.7 kg 9.4 kg 4.7 kg 9.4 kg
Packing size 363 x 304 x 145 mm 363 x 304 x 198 mm 363 x 304 x 145 mm 363 x 304 x 198 mm
Dimensions (w x h x d) 251 x 318 x 60 mm 251 x 318 x 127 mm 251 x 318 x 60 mm 251 x 318 x 127 mm(including mounting brackets)
880 – 960 MHzGSM 900
1710 – 1880 MHzGSM 1800
1920 – 2170 MHzUMTS
793 425, 782 10245Single Unit
793 426, 782 10246Double Unit
Port 2
Port 1
Port 3
Port 4
Single Unit 793 425 Double Unit 793 426 (only 1 unit shown)
Single Unit 782 10245 Double Unit 782 10246 (only 1 unit shown)
Type No. 793 425 793 426 782 10245 782 10246Single Unit Double Unit Single Unit Double Unit
Technical Data
• Designed for co-siting purposes
• Enables feeder sharing
• Can be used as a combiner near the BTS or in a reciprocal function near the antenna
• Suitable for indoor or outdoor applications
• Wall or mast mounting
• Available as a single unit, or for XPol antennasas a double unit
• Built-in lightning protection
• 793 425: Single unit, DC by-pass between all ports External DC Stop available as an accessory
• 793 426: Double unit, DC by-pass between all portsExternal DC Stop available as an accessory
• 782 10245: Single unit, DC by-pass between ports 3 and 4Built-in DC Stop between ports 1 and 4, ports 2 and 4
• 782 10246: Double unit, DC by-pass between ports 3 and 4Built-in DC Stop between ports 1 and 4, ports 2 and 4